HD 639 S1:2002
(Main)Electrical accessories - Portable residual current devices without integral overcurrent protection for household and similar use (PRCDs)
Electrical accessories - Portable residual current devices without integral overcurrent protection for household and similar use (PRCDs)
Applies to portable devices consisting of a plug, a residual current device (RCD) and one or more socket-outlets or a provision for connection. They do not incorporate overcurrent protection. They are intended for single-phase circuits for rated currents not exceeding 16 A for rated voltages not exceeding 250 V a.c., or for rated current not exceeding 32 A for rated voltages not exceeding 130 V a.c. to earth.
Elektrisches Installationsmaterial - Ortsveränderliche Fehlerstrom-Schutzeinrichtungen ohne eingebauten Überstromschutz für Hausinstallationen und für ähnliche Anwendungen (PRCDs)
Petit appareillage - Dispositifs différentiels mobiles sans dispositif de protection contre les surintensités incorporé pour usages domestiques et analogues (PCDM)
S'applique aux dispositifs mobiles comprenant une fiche de prise de courant, un dispositif différentiel incorporé, et un ou plusieurs socles de prises de courant. Elles ne comprennent pas de dispositifs de protection contre les surintensités incorporé. Elles sont destinées à des circuits monophasés pour des tensions assignées ne dépassant pas 250 V alternatifs par rapport à la terre en courant alternatif pour des courants assignés ne dépassant pas 16 A ou pour des tensions assignées ne dépassant pas 32 A.
Električni pribor - Prenosne naprave na preostali (diferenčni) tok brez vgrajene nadtokovne zaščite za uporabo v gospodinjstvu in za podobno uporabo (IEC 61540:1997 + A1:1998, spremenjen) (vsebuje popravek AC:2003)
General Information
Relations
Standards Content (Sample)
SLOVENSKI STANDARD
01-marec-2003
(OHNWULþQLSULERU3UHQRVQHQDSUDYHQDSUHRVWDOLGLIHUHQþQLWRNEUH]YJUDMHQH
QDGWRNRYQH]DãþLWH]DXSRUDERYJRVSRGLQMVWYXLQ]DSRGREQRXSRUDER,(&
$VSUHPHQMHQYVHEXMHSRSUDYHN$&
Electrical accessories - Portable residual current devices without integral overcurrent
protection for household and similar use (PRCDs)
Elektrisches Installationsmaterial - Ortsveränderliche Fehlerstrom-Schutzeinrichtungen
ohne eingebauten Überstromschutz für Hausinstallationen und für ähnliche
Anwendungen (PRCDs)
Petit appareillage - Dispositifs différentiels mobiles sans dispositif de protection contre
les surintensités incorporé pour usages domestiques et analogues (PCDM)
Ta slovenski standard je istoveten z: HD 639 S1:2002
ICS:
29.120.50 9DURYDONHLQGUXJD Fuses and other overcurrent
PHGWRNRYQD]DãþLWD protection devices
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
HARMONIZATION DOCUMENT HD 639 S1
DOCUMENT D'HARMONISATION
HARMONISIERUNGSDOKUMENT March 2002
ICS 29.120.60
English version
Electrical accessories –
Portable residual current devices
without integral overcurrent protection
for household and similar use (PRCDs)
(IEC 61540:1997 + A1:1998, modified)
Petit appareillage – Elektrisches Installationsmaterial –
Dispositifs différentiels mobiles sans Ortsveränderliche Fehlerstrom-
dispositif de protection contre les Schutzeinrichtungen ohne eingebauten
surintensités incorporé pour usages Überstromschutz für Hausinstallationen
domestiques et analogues (PCDM) und für ähnliche Anwendungen (PRCDs)
(CEI 61540:1997 + A1:1998, modifiée) (IEC 61540:1997 + A1:1998, modifiziert)
This Harmonization Document was approved by CENELEC on 2001-07-01. CENELEC members are
bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for
implementation of this Harmonization Document on a national level.
Up-to-date lists and bibliographical references concerning such national implementation may be obtained on
application to the Central Secretariat or to any CENELEC member.
This Harmonization Document exists in three official versions (English, French, German).
CENELEC members are the national electrotechnical committees of Austria, Belgium, Czech Republic,
Denmark, Finland, France, Germany, Greece, Iceland, Ireland, Italy, Luxembourg, Malta, Netherlands,
Norway, Portugal, Spain, Sweden, Switzerland and United Kingdom.
CENELEC
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
Central Secretariat: rue de Stassart 35, B - 1050 Brussels
© 2002 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.
Ref. No. HD 639 S1:2002 E
Foreword
After publication of IEC 61540:1997, Portable residual current devices without integral overcurrent protection
for household and similar use (PRCDs), the Secretariat Enquiry CLC/TC 23E(SEC)64 was launched. The
th
comments of the national committees were considered at the 14 meeting of CLC/TC 23E, where it was
decided to ask the CENELEC Technical Board for permission to prepare common modifications in the form
of a Harmonization Document (HD), a European Standard (EN) being not possible because the
requirements related to the plug and socket-outlet parts of PRCDs make reference to national standards.
This decision was approved by in July 1999 by the 100 BT, who recalled that the HD can only be included in
the list of publications ensuring compliance with the 73/23/EEC directive (see BT decisions D100/076 and
D100/077).
A draft containing common modifications to the text of IEC 61540:1997 and its amendment 1:1998 was
submitted to the formal vote and was approved by CENELEC as HD 639 S1 on 2001-07-01.
The following dates were fixed:
– latest date by which the existence of the HD
has to be announced at national level (doa) 2001-12-31
– latest date by which the HD has to be implemented
at national level by publication of a harmonized
national standard or by endorsement (dop) 2002-10-01
– latest date by which the national standards conflicting
with the HD have to be withdrawn (dow) 2005-06-01
Annexes designated "normative" are part of the body of the standard.
In this standard, annexes A, B, C, D, ZA and ZB are normative.
Annexes ZA and ZB have been added by CENELEC.
In this standard, the following print types are used:
- requirements: in roman type;
- test specifications: in italic type;
- notes: in smaller roman type.
- 3 - HD 639 S1:2002
Endorsement notice
The text of the International Standard IEC 61540:1997 and its amendment 1:1998 was approved by CENELEC
as a Harmonization Document with agreed common modifications as given below.
COMMON MODIFICATIONS
Contents
Add under annexes:
D List of tests, additional test sequences and numbers of samples for verification of
compliance of PRCDs with the requirements of electromagnetic compatibility EMC)
ZA Normative references to international publications with their corresponding European
publications
ZB Special national conditions
1 Scope
Delete in the first paragraph ", or for rated current not exceeding 32 A for rated voltages not
exceeding 130 V a.c. to earth".
th
Replace the 4 paragraph by:
"The plug and socket-outlet parts shall comply with the relevant national standard(s)."
Change in note 1 "IEC 61008-1" by "EN 61008-1".
Change note 3 to a normative text.
Replace note 3 by "NOTE 3 Void".
Delete, in note 4, "Australia and in".
2 Normative references
Delete the text of this clause and add the following note:
NOTE Normative references to international publications with their corresponding European publications are
given in annex ZA (normative).
3 Definitions
Delete the last sentence of the fourth paragraph "The use of the. IEC 60884-1".
3.1.6 Delete the text in brackets at the end of the subclause.
3.2.4.10.2 Delete the definition of Uy and replace by "Void".
4 Classification
4.4.2 Delete "(under consideration)".
5 Characteristics of PRCDs
5.3.1 Delete "and 120 V".
Delete the note.
5.3.2 Delete the two last lines of Table 1.
5.3.3 Delete "0,006 A -".
5.3.6 Delete "and 60 Hz".
5.3.7 Delete "10 I or" and "whichever is the higher".
n
5.3.8 Delete "10 I or" and "whichever is the higher".
n
Table 2 Add, in the title "(in s)" after "break time".
)
Replace "250 A" by "250 A * ".
Move the note below the table.
Add the following asterisk in the last line of the table:
)
* For IΔm = 250 A the test will be made only during the test of 9.11.2.3 with measurement of the break time. For IΔm >
250 A the test will be made only during the test of 9.9.2.2.
5.4.1 Replace in the second line "IEC 60364" by "HD 384".
5.4.2 Add, at the end of the first paragraph: "This value shall be equal to or higher than 1500 A.".
5.4.3 Add, at the end of the first paragraph: "This value shall be equal to or higher than 1500 A.".
6 Marking and other product information
6.1 Delete in item d) "and 60 Hz".
th
Replace in the 7 paragraph "PRCD itself" by "RCD part".
th
Add after the 9 paragraph:
"When an indicating means, separate from the operating means, is used, the symbol " I " or the
colour red shall be used to indicate the closed position."
th
Replace the 13 paragraph by:
"If the test button is the only means for the opening operation and is not used for the closing
operation, it shall still be marked T. In this case the colour red may be used."
th
Add after the 13 paragraph:
"Where the closing, opening and test functions are combined in one button it shall be marked T
and the colour red shall not be used for that button."
2) 7)
Table 3 Delete in the second column, second line: " " and " "
1) 6) 1) 2) 6)
Replace in the second line, first column " and "by " "
Replace in note 6 "under consideration" by "- 35 °C to 60 °C".
Delete note 7.
- 5 - HD 639 S1:2002
8 Requirements for construction and operation
8.1 Delete the note.
8.1.1.1 Replace the text by "Compliance is checked by inspections and the tests of the relevant
national standard.".
8.1.1.3 Replace the last paragraph by "Compliance is checked by the tests of 9.8."
Add at the end:
"The operation of the earthing contacts for the plug and the socket-outlet portions shall in
addition comply with the relevant national standard."
8.1.1.4 Replace the text by "Compliance is checked by the tests of the relevant national standard.".
8.1.1.5.5 Replace the last paragraph by "Compliance is checked by inspection and by the tests of 9.10 "
8.1.1.5.6 Replace the last paragraph by "Compliance is checked by verification of the requirements, if
any, of the relevant national standard."
8.1.1.5.8 Replace in the first line "and 4.1.4.1" by ", 4.1.4.1 and 4.1.4.3 (if equipped with terminals)".
8.1.1.5.9 Replace in the first line "and 4.1.4.1" by ", 4.1.4.1 and 4.1.4.3 (if equipped with terminals)".
8.1.1.5.10 Replace the first paragraph by:
"Terminals of PRCDs according to 4.1.3.1, 4.1.4.1 and 4.1.4.3 (if equipped with terminals) shall
be so located or shielded that they are unlikely to create a dangerous situation in normal use."
8.1.1.5.11 Replace in the first line "and 4.1.4.1" by ", 4.1.4.1 and 4.1.4.3 (if equipped with terminals)".
8.1.1.5.16 Delete the text of the subclause and replace by "Void".
8.1.1.5.17 Replace in the second paragraph "totally enclosed" by "protected to the degree declared by the
manufacturer".
Replace in the third paragraph "totally enclosed" by "protected to the degree of protection
declared by the manufacturer".
Add at the end of the third paragraph: "This may be achieved by means of a captive lid."
Replace the last paragraph by "Compliance is checked by inspection and by the tests of the
relevant clauses of EN 60529 or the relevant clauses, if any, of the national standard."
Delete the note.
8.1.1.5.18 Delete the last part of the sentence from "and that any failure during.".
Add: "Compliance is checked by the test of 9.6."
Delete the note.
8.1.1.5.19 Replace the second paragraph by "Compliance is checked by the tests of 9.8 and 9.28."
Delete the note.
8.1.1.5.20 Delete the text of the subclause and replace by "Void".
8.1.1.6.2 Replace "IEC 60227 or IEC 60245" by "HD 21 or HD 22".
Replace, in the last paragraph, "IEC 60227 or IEC 60245, as applicable" by "HD 21, HD 22 or
the relevant national standard".
Table 4 Delete in the first column "130/" (3 times).
Delete the two last rows.
th
8.1.2 Move in the 5 paragraph the last sentence "The test device may be used for this purpose."
after the first sentence.
th
Add at the end of the 8 paragraph "It shall not be possible for the indicator to show the "off"
state when the contacts are in the closed position."
th
Add after the 9 paragraph, the following new paragraph:
"Where the closing, opening and test functions are combined in the same button, separate
indicating means shall be provided."
Delete note 2.
Replace the last paragraph but two by "The operating means shall be securely fixed and it
shall not be possible to remove them without the use of a tool.".
8.1.3 Replace in the first paragraph "IEC 60884-1" by "the relevant national standard".
Table 5 Delete note 4 and the reference thereto in column 2.
Table 6 Delete the two last lines and the note.
8.1.7 Replace "26.5 of IEC 60884-1" by "the relevant national standard".
8.2.1 Delete the note.
8.2.1.1 Delete the text of the subclause and replace by "Void".
8.2.1.2 Add "NOTE In Switzerland shutters are not mandatory."
Replace the last paragraph by "Compliance is checked by inspection and by the test of the
relevant national standards."
8.2.1.3 Delete the text of the subclause and replace by "Void".
8.2.1.4 Delete in the first paragraph "(see also note of 8.2.1.1)".
1)
Table 7 Add in the first column, third line, after "(body)", the caption " "
Replace everywhere in the third column "IEC 60529" by "EN 60529."
2)
Add in the third column, after "9.6.1" and "9.6.2" respectively, the caption " "
Add at the bottom of the table:
"1) Excluding entry holes intended for earth and live contacts.
2) These tests are replaced by the requirements of the national standards, if any."
8.18 Replace the text of the subclause by:
"PRCDs shall not cause excessive electromagnetic disturbances and their function shall not
be unduly affected by electromagnetic phenomena likely to occur in normal use.
Compliance is checked by the tests of annex D."
- 7 - HD 639 S1:2002
Add the following new subclause:
"8.19 Behaviour of PRCDs at the limits of the ambient air temperature
PRCDs according to 4.4.1 and 4.4.2 shall operate reliably at their limits of the ambient air
temperature.
Compliance is checked by the tests of 9.9.4."
9 Tests
Table 10 Delete the two last lines and the note.
Table 12 Delete the three last lines.
9.6 Add the following paragraph:
"For plug and socket portions, tests shall be performed in accordance with the relevant
national standard. The tests below apply to all other portions of the PRCD."
rd th
9.6.1 Delete the 3 , 8 and last paragraphs.
9.6.2 Delete the text of the subclause and replace by "Void".
9.6.3 Delete the text of the subclause and replace by "Void".
9.6.4 Delete "1,5 times rated current or" and ", whichever is the greater,".
9.6.5 Replace the text of the subclause by
"Compliance is checked by the tests of the relevant national standard for plugs and socket
outlets."
9.7.2.a) Add at the end of the sentence "excluding the PE circuit"
9.7.2.b) Add before note 1:
"For this purpose, samples specially prepared by the manufacturer shall be submitted to this
test."
Change the note 1 to normative text.
9.7.2.c) Renumber note 2 to note 1.
9.7.2.d) Renumber note 3 to note 2.
9.7.3 Delete in the first paragraph ", the electronic components, if any, being disconnected for the
test".
th
Add at the end of the 6 paragraph ", electronic components, if any, being disconnected for
the tests b) and c)".
9.7.4 Replace the text of the subclause by:
"No additional insulation or dielectric tests are carried out between primary and secondary
circuits of the detection transformer."
9.8.1 Replace the last paragraph by:
"The fixed socket-outlets used for the test shall comply with the relevant requirements of the
nation
...