29.060.01 - Electrical wires and cables in general
ICS 29.060.01 Details
Electrical wires and cables in general
Drahte, Kabel und Leitungen im allgemeinen
Fils et cables electriques en general
Električne žice in kabli na splošno
General Information
- Standard9 pagesEnglish and French languagesale 15% off
IEC 61084-2-4:2017 specifies requirements and tests for cable trunking systems (CTS) and cable ducting systems (CDS) intended for the accommodation, and where necessary for the electrically protective separation, of insulated conductors, cables and possibly other electrical equipment in electrical and/or communication systems installations. The maximum voltage of these installations is 1 000 V AC and 1 500 V DC.
Service poles and service posts are intended to be mounted in free space and in contact with mounting surface(s) only at one or two ends, where the word “mounted” means fixed or placed on the floor with a weighted base or linked to a mounting surface through a flexible component.
NOTE Service poles and service posts can also be part of a CTS/CDS intended for wall or ceiling mounting covered by IEC 61084-2-1 or floor mounting covered by IEC 61084-2-2 and are then also tested according to said parts, as appropriate.
This international standard does not apply to conduit systems, cable tray systems, cable ladder systems, powertrack systems or equipment covered by other standards.
This second edition cancels and replaces the first edition published in 1996. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
- classification;
- construction;
- mechanical and electrical properties.
This International Standard is to be used in conjunction with IEC 61084-1:2017.
- Standard61 pagesEnglish and French languagesale 15% off
- Standard122 pagesEnglish and French languagesale 15% off
- Standard13 pagesEnglish and French languagesale 15% off
- Standard5 pagesEnglish and French languagesale 15% off
IEC 61084-2-1:2017 specifies requirements and tests for cable trunking systems (CTS) and cable ducting systems (CDS) intended for the accommodation, and where necessary for the electrically protective separation, of insulated conductors, cables and possibly other electrical equipment in electrical and/or communication systems installations. The maximum voltage of these installations is 1 000 V AC and 1 500 V DC.
These systems are intended for mounting on walls and/or ceilings. They can be embedded, installed in a flush or semi-flush state, surface mounted or mounted away from the surface using fixing devices.
This document does not apply to conduit systems, cable tray systems, cable ladder systems, power track systems or equipment covered by other standards.
This second edition cancels and replaces the first edition published in 1996. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
- classification;
- construction;
- mechanical and electrical properties.
This International Standard is to be used in conjunction with IEC 61084-1:2017.
- Standard49 pagesEnglish and French languagesale 15% off
- Standard105 pagesEnglish and French languagesale 15% off
IEC 61084-2-2:2017 specifies requirements and tests for cable trunking systems (CTS) and cable ducting systems (CDS) intended for the accommodation, and where necessary for the electrically protective separation, of insulated conductors, cables and possibly other electrical equipment in electrical and/or communication systems installations. The maximum voltage of these installations is 1 000 V AC and 1 500 V DC.
These systems are intended for mounting underfloor, flushfloor or onfloor.
This document does not apply to CTS/CDS which are intended to be fixed to the wall and supported by the floor.
This document does not apply to conduit systems, cable tray systems, cable ladder systems, power track systems or equipment covered by other standards.
This second edition cancels and replaces the first edition published in 2003. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
- classification;
- construction;
- mechanical and electrical properties.
This International standard is to be used in conjunction with IEC 61084-1:2017.
- Standard62 pagesEnglish and French languagesale 15% off
- Standard124 pagesEnglish and French languagesale 15% off
IEC 61084-2-3:2017 specifies requirements and tests for cable trunking systems (CTS) and cable ducting systems (CDS) intended for the accommodation, and where necessary for the electrically protective separation, of insulated conductors, cables and possibly other electrical equipment in electrical and/or communication systems installations. The maximum voltage of these installations is 1 000 V AC and 1 500 V DC.
Slotted cable trunking systems are intended for mounting inside cabinets in electrical and/or communication system installations.
This document does not apply to conduit systems, cable tray systems, cable ladder systems, power track systems or equipment covered by other standards.
This International standard is to be used in conjunction with IEC 61084-1:2017.
- Standard36 pagesEnglish and French languagesale 15% off
- Standard74 pagesEnglish and French languagesale 15% off
IEC 61084-1:2017 specifies requirements and tests for cable trunking systems (CTS) and cable ducting systems (CDS) intended for the accommodation, and where necessary for the electrically protective separation, of insulated conductors, cables and possibly other electrical equipment in electrical and/or communication systems installations. The maximum voltage of these installations is 1 000 V AC and 1 500 V DC.
This document does not apply to conduit systems, cable tray systems, cable ladder systems, power track systems or equipment covered by other standards.
This second edition cancels and replaces the first edition published in 1991 and Amendment 1:1993. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
- classification;
- construction;
- mechanical and electrical properties.
This part of the IEC 61084 series is not intended to be used by itself.
- Standard90 pagesEnglish languagesale 15% off
- Standard90 pagesEnglish and French languagesale 15% off
- Standard6 pagesEnglish languagesale 15% off
This Technical Report serves as a supplement to IEC 60364-5-52:2009 and explains the rules
so as to facilitate the design, selection, erection and maintenance of wiring systems.
It is written for everyone concerned with the design, the selection and supply of equipment, as
well as the persons who install, maintain and use electrical installations.
- Technical report13 pagesEnglish languagesale 10% offe-Library read for1 day
- Technical report25 pagesEnglish and French languagesale 15% off
This document specifies a method for the determination of the content of halogens in cable
management system (CMS) products or system components made completely or partly of
combustible material(s). The determination is made by combustion and subsequent analysis of
the combustion product by ion chromatography. This document specifies how CMS products or
system components can be declared as halogen-free.
This document is for environmental performance purposes only.
Compliance with this document does not imply the absence of toxicity, corrosivity or opacity of
produced smoke, or other reaction to fire characteristics. If any of these characteristics are to
be evaluated, the appropriate standards can be used.
The detection limit of this test method is typically 0,025 g of halogen per kg (0,002 5 %).
Halides insoluble in aqueous solution present in the original sample or produced during the
combustion step are not determined by this method.
- Standard19 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 63355:2022 specifies a method for the determination of the content of halogens in cable management system (CMS) products or system components made completely or partly of combustible material(s). The determination is made by combustion and subsequent analysis of the combustion product by ion chromatography. This document specifies how CMS products or system components can be declared as halogen-free.
- Standard19 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 63355:2022 specifies a method for the determination of the content of halogens in cable management system (CMS) products or system components made completely or partly of combustible material(s). The determination is made by combustion and subsequent analysis of the combustion product by ion chromatography. This document specifies how CMS products or system components can be declared as halogen-free.
- Standard32 pagesEnglish and French languagesale 15% off
IEC 63248:2022 specifies the properties of wires in the diameter range of, but not limited to, 1,25 mm to 5,50 mm. This document is applicable to coated or cladded metallic wires before stranding used either as concentric lay overhead stranded conductors, or in the manufacture of cores for concentric lay overhead stranded conductors, for power transmission purposes. The various wire types and their designations are listed in Table A.1. For calculation purposes the values listed in Annex B are used. This first edition cancels and replaces the first edition of IEC 61232 published in 1993 and the first edition of IEC 60888 published in 1997. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous editions of IEC 61232 and IEC 60888: a) wire designations have been modified and grouped; b) wires with zinc coating class 2 were removed; c) new wire designations have been added; d) aluminium-clad FeNi36 wires have been added; e) advanced zinc-aluminium alloy coated steel wires have been added.
- Standard39 pagesEnglish languagesale 10% offe-Library read for1 day
2020-10-19: This prAA represents common mods to prEN IEC 62641 (PR=72849)
- Amendment5 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 62641:2022 specifies the mechanical and electrical properties of round and formed wires for equivalent diameters up to the values according to Table 3 for aluminium and aluminium alloys and according to Table 4 for thermal resistant alloys. This document is applicable to aluminium and aluminium alloy wires for the manufacture of concentric lay overhead electrical stranded conductors with or without gap(s) for power transmission purposes. The various materials and their designations are listed in Table 1. For calculation purposes, the values listed in Table 1 are used. This first edition cancels and replaces the second edition of IEC 60104 published in 1987, the first edition of IEC 60121 published in 1960, the first edition of IEC 60889 published in 1987, and the first edition of IEC 62004 published in 2007. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous editions of IEC 60104, IEC 60121, IEC 60889 and IEC 62004:
designations of aluminium alloys are modified;
aluminium alloys A4, AL4 and AL5 are added;
wire diameter ranges for indicating mechanical properties are modified and extended;
test methods are merged.
- Standard19 pagesEnglish languagesale 10% offe-Library read for1 day
2019-10-31:This prAA represents common mods. to prEN IEC 63248 (PR=70075)
- Amendment9 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 62641:2022 specifies the mechanical and electrical properties of round and formed wires for equivalent diameters up to the values according to Table 3 for aluminium and aluminium alloys and according to Table 4 for thermal resistant alloys. This document is applicable to aluminium and aluminium alloy wires for the manufacture of concentric lay overhead electrical stranded conductors with or without gap(s) for power transmission purposes.
The various materials and their designations are listed in Table 1. For calculation purposes, the values listed in Table 1 are used.
This first edition cancels and replaces the second edition of IEC 60104 published in 1987, the first edition of IEC 60121 published in 1960, the first edition of IEC 60889 published in 1987, and the first edition of IEC 62004 published in 2007. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous editions of IEC 60104, IEC 60121, IEC 60889 and IEC 62004:
designations of aluminium alloys are modified;
aluminium alloys A4, AL4 and AL5 are added;
wire diameter ranges for indicating mechanical properties are modified and extended;
test methods are merged.
- Standard34 pagesEnglish and French languagesale 15% off
IEC 63248:2022 specifies the properties of wires in the diameter range of, but not limited to, 1,25 mm to 5,50 mm. This document is applicable to coated or cladded metallic wires before stranding used either as concentric lay overhead stranded conductors, or in the manufacture of cores for concentric lay overhead stranded conductors, for power transmission purposes.
The various wire types and their designations are listed in Table A.1. For calculation purposes the values listed in Annex B are used.
This first edition cancels and replaces the first edition of IEC 61232 published in 1993 and the first edition of IEC 60888 published in 1997. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous editions of IEC 61232 and IEC 60888:
a) wire designations have been modified and grouped;
b) wires with zinc coating class 2 were removed;
c) new wire designations have been added;
d) aluminium-clad FeNi36 wires have been added;
e) advanced zinc-aluminium alloy coated steel wires have been added.
- Standard75 pagesEnglish and French languagesale 15% off
2021-04-20: amdt to allow citation of main standard - when pos assessed to request BT approval
- Amendment5 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 61316:2021 is available as IEC 61316:2021 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 61316:2021 applies to cable reels provided with a non-detachable flexible cable with a rated operating voltage not exceeding 690 V DC and/or 690 V AC with a frequency not exceeding 500 Hz and a rated current not exceeding 63 A, primarily intended for industrial use, either indoors or outdoors, for use with accessories complying with IEC 60309-1, IEC 60309-2 or IEC 60309-4. This third edition cancels and replaces the second edition, published in 1999. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: - Implementation of the latest tests and requirements previously included in IEC 60309-1.
- Standard59 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 61316:2021 is available as IEC 61316:2021 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.
IEC 61316:2021 applies to cable reels provided with a non-detachable flexible cable with a rated operating voltage not exceeding 690 V DC and/or 690 V AC with a frequency not exceeding 500 Hz and a rated current not exceeding 63 A, primarily intended for industrial use, either indoors or outdoors, for use with accessories complying with IEC 60309-1, IEC 60309-2 or IEC 60309-4. This third edition cancels and replaces the second edition, published in 1999. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
- Implementation of the latest tests and requirements previously included in IEC 60309-1.
- Standard172 pagesEnglish languagesale 15% off
- Standard113 pagesEnglish and French languagesale 15% off
This European Standard establishes the requirements and tests for cover plates and cover tapes used for the mechanical protection, identification and warning of the location of buried cables or buried conduits.
- Standard17 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 62568:2015 provides test procedures to measure the fatigue characteristics of conductor/clamp systems. For the purposes of this standard, clamps shall be of the metallic type only. Key words: Conductors, Fatigue, Fatigue test
- Standard33 pagesEnglish and French languagesale 15% off
2014-10-15: Corrigendum to add missing revision link between HD 60364-7-753:2014 and HD 384-7-753 S1:2002
- Corrigendum1 pageEnglish languagesale 10% offe-Library read for1 day
This part of IEC 60364 applies to embedded electric heating systems for surface heating. It also applies to electric heating systems for de-icing or frost prevention or similar applications. Both indoor and outdoor systems are covered. Heating systems for industrial and commercial applications complying with relevant parts of IEC 60519, IEC 62395 and IEC 60079 are not covered. NOTE Examples of heating systems covered by this standard are heating systems for walls, ceilings, floors, roofs, drainpipes, gutters, pipes, stairs, roadways, non-hardened compacted areas (e.g. football fields, lawns).
- Standardization document18 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 62567:2013 provides test procedures based on the documents mentioned in the introduction and devoted to minimize the causes of discrepancy between test results, taking into consideration the large experience accumulated in the last 30 years by numerous test engineers and available in literature, including a CIGRE Technical Brochure specifically referring to this standard (see Bibliography). This Standard describes the current methodologies, including apparatus, procedures and accuracies, for the measurement of conductor self-damping and for the data reduction formats. In addition, some basic guidance is also provided to inform the potential user of a given method's strengths and weaknesses. The methodologies and procedures incorporated in this Standard are applicable only to testing on indoor laboratory spans. Key words: Overhead lines, Self-damping, Conductors
- Standard74 pagesEnglish and French languagesale 15% off
IEC/TR 61200-52:2013 is Technical Report which serves as a supplement to IEC 60364-5-52:2009 and explains the rules so as to facilitate the design, selection, erection and maintenance of wiring systems. It follows the numbering of that standard. This technical report is written for everyone concerned with the design, the selection and supply of equipment, as well as the persons who install, maintain and use electrical installations. This second edition cancels and replaces the first edition, published in 1993, and constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
- guidance associated with conduit systems, cable ducting systems, cable trunking systems, cable tray systems and cable ladder systems has been added giving, for example, recommended maximum straight lengths of conduit to ease the installation circuit wiring;
- guidance associated with selection and erection of wiring systems in relation to external influences has been extended to cover impact, and other mechanical stresses;
- guidance for grouping of cables has been added; and
- guidance on maximum temperatures of terminals in normal service conditions has been extended.
- Technical report13 pagesEnglish languagesale 10% offe-Library read for1 day
- Technical report25 pagesEnglish and French languagesale 15% off
- Technical report10 pagesEnglish languagesale 15% off
IEC 62491:2008 provides rules and guidelines for the labelling of cables and cores/conductors used in industrial installations, equipment and products, in order to maintain a clear relation between the technical documentation and the actual equipment and for other purposes. International Standard IEC 62491 has been prepared by IEC technical committee 3: Information structures, documentation and graphical symbols.
- Standard33 pagesEnglish languagesale 10% offe-Library read for1 day
This Technical Report applies to low-voltage installations with a nominal system frequency of 50 Hz in which the circuits consist of insulated conductors, cables or busbar trunking systems.
It defines the different parameters used for the calculation of the characteristics of electrical wiring
systems in order to comply with rules of HD 384/HD 60364.
These rules are mainly the following:
- current-carrying capacities of the conductors;
- characteristics of protective devices in regard to protection against overcurrent;
- verification of thermal stress in conductors due to short-circuit current or earth fault current;
- fault protection (protection against indirect contact) in TN systems and IT systems;
- limitation of voltage drop;
- verification of mechanical stresses during short-circuit in busbar trunking systems (BTS) according to EN 60439-2 or powertrack systems according to EN 61534 series.
The calculations provided in this Technical Report are only applicable where the characteristics of the circuits are known.
For the purpose of this document, when referring to Busbar Trunking Systems, Powertrack Systems
are also considered.
NOTE 1 Mechanical stress during short-circuit is covered by IEC 60865.
NOTE 2 In general these calculations concern supply by HV/LV transformer, but they are also applicable to supply by LV/LV transformer and LV back-up generators.
NOTE 3 Effects of harmonics currents are not covered by this document.
This Technical Report is also applicable for checking the compliance of the results of calculations
performed by software programs for calculation of cross-sectional area of insulated conductors, crosssectional area of cables and characteristics for selection of busbar trunking systems with
HD 384/HD 60364.
- Technical report35 pagesEnglish languagesale 10% offe-Library read for1 day
This standard gives guidance on writing the technical specification for the procurement of equipment for use in electricity generating stations (power stations). This Guide for procurement is not applicable to equipment for use in the nuclear reactor plant area of nuclear power stations. Other possible applications of such equipment have not been considered in the preparation of this Guide. This Guide on cabling systems deals with a wide range of activities and may be used for any or all of these activities by selection of the relevant parts e.g.: - provision of support for cable; - laying of cable; - completion of cable ends; The Guide covers the installation of power cable up to and including 20,8/36 (42) kV and the supply and installation of control and instrumentation cable. The supply of power cable is covered by EN 45510-2-8. The Guide includes the installation of protective conductor cable for earthing and equipotential bonding up to the main earthing busbar(s), but not the below ground earth-electrode network. The equipment covered by this Guide is defined by its function rather than design type. Therefore, the guidance to the specification is stated in performance terms rather than being specified by a detailed description of the equipment to be supplied. This Guide indicates to potential purchasers how their specification should be prepared so that - the equipment type and capacity interfaces correctly with other elements of the systems, - predicted performance is achieved, - ancillary equipment is properly sized, - reliability, availability and safety requirements are achieved, - proper consideration is given to the evaluation process and the quality measures to be applied. This Guide does not determine the type of specification (e.g. detailed, performance, functional) or the extent of supply for any given contract which is normally decided on the basis of the purchaser's project strategy. It does not cover - any commercial, contractual or legal issues which are normally in separate parts of an enquiry, - any allocation of responsibilities which are determined by the contract. This Guide does not prescribe the arrangement of the documents in the enquiry. NOTE As a comprehensive European environmental policy is still under preparation, this Guide does not address the environmental implications of the equipment.
- Standard51 pagesEnglish languagesale 10% offe-Library read for1 day
This Technical Report applies to low-voltage installations with a nominal system frequency of 50 Hz in which the circuits consist of insulated conductors, cables or busbar trunking systems. It defines the different parameters used for the calculation of the characteristics of electrical wiring systems in order to comply with rules of HD 384/HD 60364. These rules are mainly the following: - current-carrying capacities of the conductors; - characteristics of protective devices in regard to protection against overcurrent; - verification of thermal stress in conductors due to short-circuit current or earth fault current; - fault protection (protection against indirect contact) in TN systems and IT systems; - limitation of voltage drop; - verification of mechanical stresses during short-circuit in busbar trunking systems (BTS) according to EN 60439-2 or powertrack systems according to EN 61534 series. The calculations provided in this Technical Report are only applicable where the characteristics of the circuits are known. For the purpose of this document, when referring to Busbar Trunking Systems, Powertrack Systems are also considered. NOTE 1 Mechanical stress during short-circuit is covered by IEC 60865. NOTE 2 In general these calculations concern supply by HV/LV transformer, but they are also applicable to supply by LV/LV transformer and LV back-up generators. NOTE 3 Effects of harmonics currents are not covered by this document. This Technical Report is also applicable for checking the compliance of the results of calculations performed by software programs for calculation of cross-sectional area of insulated conductors, cross-sectional area of cables and characteristics for selection of busbar trunking systems with HD 384/HD 60364.
- Technical report35 pagesEnglish languagesale 10% offe-Library read for1 day
This standard provides rules and guidelines for the labelling of cables and cores/conductors used in industrial installations, equipment and products, in order to maintain a clear relation between the technical documentation and the actual equipment and for other purposes. The following methods are described and designated: - use of coloured cables and designated cores; - additional identification labelling; - additional connection labelling; and - additional signal labelling. The physical design of the labels, the material to be used for the labels as well as cable manufacturers' product bound marking of cables and cores are not part of this standard.
- Standard33 pagesEnglish languagesale 10% offe-Library read for1 day
Applies to the limitation of temperature rises of connecting interfaces in normal service conditions. This publication has the status of a technical report, type 2.
- Technical report8 pagesEnglish languagesale 10% offe-Library read for1 day
applies to low-frequency cables and wires for telecommunication and gives a general method for calculating the resistance of copper conductors. includes the following significant technical change with respect to the previous edition: improvement of the calculation method of the resistance of copper conductors. The contents of the corrigendum of February 2012 have been included in this copy.
- Technical report7 pagesEnglish languagesale 15% off
This part of IEC 61084 specifies requirements for cable trunking systems and cable ducting systems intended for the accommodation, and where necessary for the segregation, of conductors, cables or cords and/or other electrical equipment in electrical installations. This standard applies to cable trunking systems and cable ducting systems which are mounted beneath or flush with the top face of the finished floor, including their system components. This specification does not apply to conduits, cable trays or cable ladders or to current-carrying parts within the system.
- Standard27 pagesEnglish languagesale 15% off
- Standard27 pagesFrench languagesale 15% off
- Standard53 pagesEnglish and French languagesale 15% off
Specifies the electrical and mechanical characteristics of concentric lay, overhead conductors of wires formed or shaped before, during or after stranding, made of combinations of any of the following metal wires: a) hard aluminium as per EN 60889 designated A1; b) hard aluminium as per EN 60889 designated A1F wire shaped before stranding; c) hard aluminium alloy as per EN 60104 designated A2 or A3; d) hard aluminium alloy as per EN 60104 designated A2F or A3F shaped before stranding; e) regular strength steel, designated S1A or S1B, where A and B are zinc coating classes, corresponding respectively to classes 1 and 2; f) high strength steel, designated S2A or S2B; g) extra high strength steel, designated S3A; h) aluminium clad steel, designated SA.
- Standard27 pagesEnglish languagesale 10% offe-Library read for1 day
Specifies the electrical and mechanical characteristics of concentric lay, overhead conductors of wires formed or shaped before, during or after stranding, made of combinations of any of the following metal wires: a) hard aluminium as per IEC 60889 designated A1; b) hard aluminium as per IEC 60889 designated A1F wire shaped before stranding; c) hard aluminium alloy as per IEC 60104 designated A2 or A3; d) hard aluminium alloy as per IEC 60104 designated A2F or A3F shaped before stranding; e) regular strength steel, designated S1A or S1B, where A and B are zinc coating classes, corresponding respectively to classes 1 and 2; f) high strength steel, designated S2A or S2B; g) extra high strength steel, designated S3A; h) aluminium clad steel, designated SA.
- Standard47 pagesEnglish and French languagesale 15% off
Applies to cable reels with a rated operating voltage not exceeding 690 V a.c./d.c. and 500 Hz with a rated current not exceeding 63A, primarily intended to industrial use, either indoors or outdoors, for use with accessories complying with IEC 60309-1.
- Standard55 pagesEnglish and French languagesale 15% off
- Standard43 pagesEnglish and French languagesale 15% off
- Standard3 pagesEnglish and French languagesale 15% off
This part 2-3 of the EN IEC 61084 series specifies particular requirements and tests slotted cable trunking systems intended for mounting inside cabinets in electrical and/or communication system installations.
- Draft20 pagesEnglish languagesale 10% offe-Library read for1 day
This part 1 of the EN IEC 61084 series specifies general requirements and tests for cable trunking systems (CTS) and cable ducting systems (CDS) intended for the accommodation, and where necessary for the electrically protective separation, of insulated conductors, cables and possibly other electrical equipment in electrical and/or communication systems installations. The maximum voltage of these installations is 1 000 V AC and 1 500 V DC.
- Draft47 pagesEnglish languagesale 10% offe-Library read for1 day
This part 2-2 of the EN IEC 61084 series specifies particular requirements and tests for cable trunking systems (CTS) and cable ducting systems (CDS) intended for mounting underfloor, flushfloor or onfloor.
- Draft33 pagesEnglish languagesale 10% offe-Library read for1 day
Common modifications for the adoption as a European Standard of IEC 61084-1:2017 ed 2.0 (PR= 69866).
- Draft5 pagesEnglish languagesale 10% offe-Library read for1 day
Common modifications for the adoption as a European Standard of IEC 61084-2-2:2017 ed 2.0 (PR= 72101).
- Draft7 pagesEnglish languagesale 10% offe-Library read for1 day
Common modifications for the adoption as a European Standard of IEC 61084-2-1:2017 ed 2.0 (PR=72100)
- Draft7 pagesEnglish languagesale 10% offe-Library read for1 day
This part 2-1 of the EN IEC 61084 series specifies particular requirements and tests for cable trunking systems (CTS) and cable ducting systems (CDS) intended for intended for mounting on walls and ceilings. They can be embedded, installed in a flush or semi-flush state, surface mounted or mounted away from the surface using fixing devices.
- Draft27 pagesEnglish languagesale 10% offe-Library read for1 day