Flexible insulating sleeving - Part 3: Specifications for individual types of sleeving - Sheet 282: Heat-shrinkable, polyolefin sleeving - Stress control

IEC 60684-3-282:2010 gives the requirements for two types of heat-shrinkable, polyolefin sleeving, stress control, not flame retarded, with a nominal shrink ratio up to 3:1. This sleeving has been found suitable for use up to temperatures of 100 °C. - Type A: Medium wall - Internal diameter up to 65,0 mm typically - Type B: Thick wall - Internal diameter up to 95,0 mm typically

Isolierschläuche - Teil 3: Anforderungen für einzelne Schlauchtypen - Blatt 282: Polyolefin-Wärmeschrumpfschläuche mit Feldsteuerung

Gaines isolantes souples - Partie 3: Spécifications pour types particuliers de gaines - Feuille 282: Gaines thermorétractables en polyoléfine - Contrôle de fatigue

La CEI 60684-3-282:2010 donne les exigences relatives à deux types de gaines thermorétractables, en polyoléfine, à contrôle de fatigue, non ignifugées, de rapport de rétreint nominal jusqu'à 3:1. Ces gaines se sont révélées être adaptées à une utilisation à des températures jusqu'à 100 °C. - Type A: Paroi moyenne - Diamètre intérieur type jusqu'à 65,0 mm - Type B: Paroi épaisse - Diamètre intérieur type jusqu'à 95,0 mm

Gibke izolacijske cevi - 3. del: Specifikacije za posamezne tipe cevi - 282. list: Toplotno skrčljive poliolefinske cevi, preskušanje z obremenjevanjem (IEC 60684-3-282:2010)

Ta del IEC 60684 podaja zahteve za dva tipa toplotno skrčljivih poliolefinskih cevi za preskušanje z obremenjevanjem, ki niso ognjevarne in ki imajo nazivno razmerje krčenja do 3:1. Za te cevi je ugotovljeno, da so primerne za uporabo pri temperaturah do 100 °C.
- Tip A: Srednje debela stena. Notranji premer običajno do 65,0 mm.
- Tip B: Debela stena. Notranji premer običajno do 95,0 mm.
Te cevi se običajno dobavljajo v črni barvi. Ker te vrste cevi zajemajo precej velik razpon velikosti in debelin stene, podajata preglednici A.1. in A.2 v tem standardu vodilo o razponu razpoložljivih velikosti. Dejanska velikost se dogovori med uporabnikom in dobaviteljem. Materiali, skladni s to specifikacijo, ustrezajo vzpostavljenim ravnem delovanja. Vendar mora uporabnik material za določeno uporabo izbrati na podlagi dejanskih zahtev za ustrezno delovanje pri takšni uporabi, in ne le na podlagi same specifikacije. Ta cevi so zasnovane za uporabo v kabelskih dodatkih srednje napetosti, zato mora biti dokazana njihova električna zmogljivost, kadar so del sklopa. Primeri tega so opisani v HD 629 in seriji IEC 60502.

General Information

Status
Published
Publication Date
09-Sep-2010
Withdrawal Date
31-Aug-2013
Drafting Committee
Parallel Committee
Current Stage
6060 - Document made available - Publishing
Start Date
10-Sep-2010
Completion Date
10-Sep-2010

Buy Standard

Standard
EN 60684-3-282:2010
English language
12 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

SLOVENSKI STANDARD
SIST EN 60684-3-282:2010
01-december-2010
*LENHL]RODFLMVNHFHYLGHO6SHFLILNDFLMH]DSRVDPH]QHWLSHFHYLOLVW
7RSORWQRVNUþOMLYHSROLROHILQVNHFHYLSUHVNXãDQMH]REUHPHQMHYDQMHP ,(&

Flexible insulating sleeving - Part 3: Specifications for individual types of sleeving - Sheet
282: Heat-shrinkable, polyolefin sleeving - Stress control (IEC 60684-3-282:2010)
Isolierschläuche - Teil 3: Anforderungen für einzelne Schlauchtypen - Blatt 282:
Polyolefin- Wärmeschrumpfschläuche mit Feldsteuerung (IEC 60684-3-282:2010)
Gaines isolantes souples - Partie 3: Spécifications pour types particuliers de gaines -
Feuille 282: Gaines thermorétractables en polyoléfine - Contrôle de fatigue (CEI 60684-3
-282:2010)
Ta slovenski standard je istoveten z: EN 60684-3-282:2010
ICS:
29.035.20 3ODVWLþQLLQJXPHQLL]RODFLMVNL Plastics and rubber insulating
PDWHULDOL materials
SIST EN 60684-3-282:2010 en
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------

SIST EN 60684-3-282:2010

---------------------- Page: 2 ----------------------

SIST EN 60684-3-282:2010

EUROPEAN STANDARD
EN 60684-3-282

NORME EUROPÉENNE
September 2010
EUROPÄISCHE NORM

ICS 29.035.20


English version


Flexible insulating sleeving -
Part 3: Specifications for individual types of sleeving -
Sheet 282: Heat-shrinkable, polyolefin sleeving -
Stress control
(IEC 60684-3-282:2010)


Gaines isolantes souples -  Isolierschläuche -
Partie 3: Spécifications pour types Teil 3: Anforderungen für einzelne
particuliers de gaines - Schlauchtypen -
Feuille 282: Gaines thermorétractables Blatt 282: Polyolefin-
en polyoléfine - Wärmeschrumpfschläuche
Contrôle de fatigue mit Feldsteuerung
(CEI 60684-3-282:2010) (IEC 60684-3-282:2010)




This European Standard was approved by CENELEC on 2010-09-01. CENELEC members are bound to comply
with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard
the status of a national standard without any alteration.

Up-to-date lists and bibliographical references concerning such national standards may be obtained on
application to the Central Secretariat or to any CENELEC member.

This European Standard exists in three official versions (English, French, German). A version in any other
language made by translation under the responsibility of a CENELEC member into its own language and notified
to the Central Secretariat has the same status as the official versions.

CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus,
the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy,
Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia,
Spain, Sweden, Switzerland and the United Kingdom.

CENELEC
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung

Management Centre: Avenue Marnix 17, B - 1000 Brussels


© 2010 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.
Ref. No. EN 60684-3-282:2010 E

---------------------- Page: 3 ----------------------

SIST EN 60684-3-282:2010
EN 60684-3-282:2010 - 2 -
Foreword
The text of document 15/564/FDIS, future edition 1 of IEC 60684-3-282, prepared by IEC TC 15, Solid
electrical insulating materials, was submitted to the IEC-CENELEC parallel vote and was approved by
CENELEC as EN 60684-3-282 on 2010-09-01.
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. CEN and CENELEC shall not be held responsible for identifying any or all such patent
rights.
The following dates were fixed:
– latest date by which the EN has to be implemented
at national level by publication of an identical
(dop) 2011-06-01
national standard or by endorsement
– latest date by which the national standards conflicting
(dow) 2013-09-01
with the EN have to be withdrawn
Annex ZA has been added by CENELEC.
__________
Endorsement notice
The text of the International Standard IEC 60684-3-282:2010 was approved by CENELEC as a European
Standard without any modification.
__________

---------------------- Page: 4 ----------------------

SIST EN 60684-3-282:2010
- 3 - EN 60684-3-282:2010
Annex ZA
(normative)

Normative references to international publications
with their corresponding European publications

The following referenced documents are indispensable for the application of this document. For dated
references, only the edition cited applies. For undated references, the latest edition of the referenced
document (including any amendm
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.