High-voltage switchgear and controlgear - Part 101: Synthetic testing

Supersedes EN 60427:2000 * Superseded by EN 62271-101:2013

Hochspannungs-Schaltgeräte und -Schaltanlagen - Teil 101: Synthetische Prüfung

Appareillage à haute tension - Partie 101: Essais synthétiques

Visokonapetostne stikalne in krmilne naprave 101. del: Sintetično preskušanje (IEC 62271-101:2006)

Ta del IEC 6227 večinoma velja za prekinjevalce izmeničnega toku v okviru IEC 62271-100. Zagotavlja splošna pravila za preskušanje prekinjevalcev izmeničnega toka, za zmogljivost proizvajanja in prekinitve v razponu preskusnih funkcij, ki so opisane od točke 6.102 do 6.111 IEC 62271-100, s sintetičnimi metodami. Dokazano je bilo, da je sintetično preskušanje ekonomičen in tehnično pravilen način preskušanja visoko napetostnih prekinjevalcev izmeničnega toka v skladu z zahtevami IEC 62271-100 ter da je enakovredno neposrednemu preskušanju. Opisane metode in tehnike so tiste, ki so v splošni rabi. Namen tega standarda je vzpostaviti merila za sintetično preskušanje in za primerno ovrednotenje rezultatov. Takšna merila vzpostavljajo veljavnost preskusne metode brez omejitev glede inovativnosti preskusnega vezja.

General Information

Status
Withdrawn
Publication Date
24-Jul-2006
Withdrawal Date
30-Jun-2009
Current Stage
9960 - Withdrawal effective - Withdrawal
Start Date
16-Nov-2015
Completion Date
16-Nov-2015

Relations

Buy Standard

Standard
EN 62271-101:2006
English language
144 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

SLOVENSKI STANDARD
SIST EN 62271-101:2006
01-december-2006
1DGRPHãþD
SIST EN 60427:2000
9LVRNRQDSHWRVWQHVWLNDOQHLQNUPLOQHQDSUDYHGHO6LQWHWLþQRSUHVNXãDQMH
,(&
High-voltage switchgear and controlgear - Part 101: Synthetic testing (IEC 62271-
101:2006)
Hochspannungs-Schaltgeräte und -Schaltanlagen - Teil 101: Synthetische Prüfung (IEC
62271-101:2006)
Appareillage a haute tension - Partie 101: Essais synthétiques (CEI 62271-101:2006)
Ta slovenski standard je istoveten z: EN 62271-101:2006
ICS:
29.130.10 Visokonapetostne stikalne in High voltage switchgear and
krmilne naprave controlgear
SIST EN 62271-101:2006 en,fr,de
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------

SIST EN 62271-101:2006

---------------------- Page: 2 ----------------------

SIST EN 62271-101:2006


EUROPEAN STANDARD
EN 62271-101

NORME EUROPÉENNE
July 2006
EUROPÄISCHE NORM

ICS 29.130.10 Supersedes EN 60427:2000


English version


High-voltage switchgear and controlgear
Part 101: Synthetic testing
(IEC 62271-101:2006)


Appareillage à haute tension  Hochspannungs-Schaltgeräte
Partie 101: Essais synthétiques und -Schaltanlagen
(CEI 62271-101:2006) Teil 101: Synthetische Prüfung
(IEC 62271-101:2006)




This European Standard was approved by CENELEC on 2006-07-01. CENELEC members are bound to comply
with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard
the status of a national standard without any alteration.

Up-to-date lists and bibliographical references concerning such national standards may be obtained on
application to the Central Secretariat or to any CENELEC member.

This European Standard exists in three official versions (English, French, German). A version in any other
language made by translation under the responsibility of a CENELEC member into its own language and notified
to the Central Secretariat has the same status as the official versions.

CENELEC members are the national electrotechnical committees of Austria, Belgium, Cyprus, the Czech
Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia,
Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain,
Sweden, Switzerland and the United Kingdom.

CENELEC
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung

Central Secretariat: rue de Stassart 35, B - 1050 Brussels


© 2006 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.
Ref. No. EN 62271-101:2006 E

---------------------- Page: 3 ----------------------

SIST EN 62271-101:2006
EN 62271-101:2006 - 2 -
Foreword
The text of document 17A/753/FDIS, future edition 1 of IEC 62271-101, prepared by SC 17A,
High-voltage switchgear and controlgear, of IEC TC 17, Switchgear and controlgear, was submitted to the
IEC-CENELEC parallel vote and was approved by CENELEC as EN 62271-101 on 2006-07-01.
This European Standard supersedes EN 60427:2000.
This standard shall be read in conjunction with EN 62271-100:2001. The numbering of the subclauses of
Clause 6 is the same as in EN 62271-100. However, not all subclauses of EN 62271-100 are addressed;
merely those where synthetic testing has introduced changes.
The following dates were fixed:
– latest date by which the EN has to be implemented
at national level by publication of an identical
national standard or by endorsement (dop) 2007-04-01
– latest date by which the national standards conflicting
with the EN have to be withdrawn (dow) 2009-07-01
Annex ZA has been added by CENELEC.
__________
Endorsement notice
The text of the International Standard IEC 62271-101:2006 was approved by CENELEC as a European
Standard without any modification.
__________

---------------------- Page: 4 ----------------------

SIST EN 62271-101:2006
- 3 - EN 62271-101:2006
Annex ZA
(normative)

Normative references to international publications
with their corresponding European publications

The following referenced documents are indispensable for the application of this document. For dated
references, only the edition cited applies. For undated references, the latest edition of the referenced
document (including any amendments) applies.

NOTE  When an international publication has been modified by common modifications, indicated by (mod), the relevant EN/HD
applies.

Publication Year Title EN/HD Year

IEC/TS 61633 1995 High-voltage alternating current circuit-- -
breakers - Guide for short-circuit and
switching test procedures for metal-enclosed
and dead tank circuit-breakers


IEC 62271-100 2001 High-voltage switchgear and contro
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.