Status
Not Published
Publication Date
06-Dec-2026
Current Stage
5060 - Voting results sent to TC, SR - Formal Approval
Start Date
04-Sep-2026
Completion Date
04-Sep-2026

Buy Documents

Draft

EN IEC 61169-54:2021/oprA1:2025

English language (2 pages)
Preview
Preview
e-Library read for
×1 day

EN IEC 61169-54:2021/FprA1:2026 is a CLC amendment to the sectional specification for radio-frequency (RF) coaxial connectors in Series 4,3-10. It updates the mechanical data for connectors with a 10 mm inner diameter of outer conductor and a nominal characteristic impedance of 50 Ω. Engineers, manufacturers, test laboratories and buyers use it when the coupling and mechanical performance of these connectors has to be specified or checked.

What does EN IEC 61169-54:2021/FprA1:2026 specify?

EN IEC 61169-54:2021/FprA1:2026 specifies one amendment to the RF connector sectional specification for coaxial connectors in Series 4,3-10. Its main effect is to change the coupling torque requirement for screw type connectors and to replace the mechanical data in Table 8 of IEC 61169-54 Edition 2 (2021-08).

The amendment is organized as a short front matter, a purpose statement, the replacement mechanical-data table, and a reasoning note. In practice, that means readers use it together with the base part to apply the revised mechanical values.

What are the key requirements of EN IEC 61169-54:2021/FprA1:2026?

The amendment focuses on the mechanical data for the connector interface. The most important point is the revised coupling torque for screw type connectors, because this is the setting that affects how firmly the connector locks in service.

Mechanical strength and coupling

  • Clause 9.3.11 updates strength of coupling mechanism for screw type connectors to a coupling torque of 5-10 N m and a proof torque of > 10 N m. In practice, this tells manufacturers and users what tightening behavior the coupling mechanism has to tolerate.
  • The reasoning states that limiting coupling torque to 5 N·m led to loosening under tower vibrations, and that 10 N·m solved the problem. In practice, this explains why the torque range matters for outdoor or vibrating installations.

Contact retention and mating forces

  • Clause 9.3.5 gives centre contact captivation with a maximum axial displacement of 0,25 mm and an axial force of 30 N. This matters because the centre contact has to stay properly retained during handling and use.
  • Clause 9.3.6 gives engagement and separation force for push pull connectors as typically 100 N for engagement and 80 N for separation. In practice, this defines how hard the connector is to mate and unmate.
  • Clause 9.3.4 gives insertion force of at least 1,5 N for the centre contact and at least 4 N for the outer contact. This helps confirm that the contact interface can be assembled without excessive force.

Cable-fixing checks

  • Clauses 9.3.7 to 9.3.10 point to mechanical tests on cable fixing: cable rotation, cable pulling, cable bending and cable torsion. In practice, these checks are used to verify the connector-cable interface under installation and service stresses.

What terms does EN IEC 61169-54:2021/FprA1:2026 define?

  • RF - Radio-frequency, the signal range covered by these connectors.
  • Screw type - A connector coupling style tightened by thread engagement.
  • Push pull - A coupling style that mates and separates by axial movement.
  • Coupling torque - The tightening torque applied to the connector coupling mechanism.
  • Proof torque - A higher torque level used to show the coupling can withstand overload without failure.
  • Centre contact captivation - The retention of the centre contact against axial movement.
  • Insertion force - The force needed to insert the centre or outer contact.
  • Series 4,3-10 - The product series named in the standard for this connector family.

Who uses EN IEC 61169-54:2021/FprA1:2026?

EN IEC 61169-54:2021/FprA1:2026 is used by connector manufacturers, test laboratories, design engineers, and quality or purchasing teams that specify RF coaxial connectors. It is especially relevant where screw type connectors may be exposed to vibration, because the torque setting affects field reliability and customer acceptance.

What changed in EN IEC 61169-54:2021/FprA1:2026 from the previous edition?

Compared with IEC 61169-54 Edition 2 (2021-08), Amendment 1 updates the coupling torque requirement for screw type connectors and replaces the mechanical data in Table 8. The reasoning note links the change to field complaints about loosening under tower vibration and to test results showing that 10 N·m addresses the issue.

Which standards are used with EN IEC 61169-54:2021/FprA1:2026?

The amendment is used with IEC 61169-54 Edition 2 (2021-08), which provides the base sectional specification and the Table 8 mechanical data that this amendment replaces.

What does the EN IEC 61169-54:2021/FprA1:2026 document contain?

The document contains a short amendment front matter, the purpose of the amendment, a replacement mechanical-data table, and a reasoning note. The table covers centre contact captivation, engagement and separation force, strength of coupling mechanism, insertion force, and mechanical tests on cable fixing. It is the part readers use for design review, compliance checking and test planning.

Relations

Effective Date
15-Apr-2025

Buy Documents

Draft

EN IEC 61169-54:2021/oprA1:2025

English language (2 pages)
Preview
Preview
e-Library read for
×1 day

Get Certified

Connect with accredited certification bodies for this standard

ANCE

Mexican certification and testing association.

EMA Mexico Verified

Intertek Slovenia

Intertek testing, inspection, and certification services in Slovenia.

UKAS Slovenia Verified

LNE (Laboratoire National de Métrologie et d'Essais)

French national laboratory for metrology and testing.

COFRAC France Verified

Sponsored listings

Frequently Asked Questions

EN IEC 61169-54:2021/FprA1:2026 is a draft published by CLC. Its full title is "Amendment 1 - Radio-frequency connectors - Part 54: Sectional specification for coaxial connectors with 10 mm inner diameter of outer conductor, nominal characteristic impedance 50 Ω, Series 4,3-10". This standard covers: Amendment 1 - Radio-frequency connectors - Part 54: Sectional specification for coaxial connectors with 10 mm inner diameter of outer conductor, nominal characteristic impedance 50 Ω, Series 4,3-10

Amendment 1 - Radio-frequency connectors - Part 54: Sectional specification for coaxial connectors with 10 mm inner diameter of outer conductor, nominal characteristic impedance 50 Ω, Series 4,3-10

EN IEC 61169-54:2021/FprA1:2026 is classified under the following ICS (International Classification for Standards) categories: 33.120.30 - RF connectors. The ICS classification helps identify the subject area and facilitates finding related standards.

EN IEC 61169-54:2021/FprA1:2026 has the following relationships with other standards: It is inter standard links to EN IEC 61169-54:2021. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.

EN IEC 61169-54:2021/FprA1:2026 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.

Standards Content (Sample)


SLOVENSKI STANDARD
SIST EN IEC 61169-54:2021/oprA1:2025
01-oktober-2025
Radiofrekvenčni konektorji - 54. del: Področna specifikacija za koaksialne
konektorje z notranjim premerom zunanjih vodnikov 10 mm in nazivno
karakteristično impendanco 50 ohm, serija 4,3-10 - Dopolnilo A1
Amendment 1 - Radio frequency connectors - Part 54: Sectional specification for coaxial
connectors with 10 mm inner diameter of outer conductor, nominal characteristic
impedance 50 Ω, Series 4,3-10
Connecteurs pour fréquences radioélectriques - Partie 54: Spécification intermédiaire
relative aux connecteurs coaxiaux avec diamètre intérieur du conducteur extérieur de 10
mm, impédance caractéristique nominale de 50 ω, série 4,3-10
Ta slovenski standard je istoveten z: EN IEC 61169-54:2021/prA1:2025
ICS:
33.120.30 Radiofrekvenčni konektorji RF connectors
(RF)
SIST EN IEC 61169-54:2021/oprA1:2025 en
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

SIST EN IEC 61169-54:2021/oprA1:2025

SIST EN IEC 61169-54:2021/oprA1:2025
46F/711/CDV
COMMITTEE DRAFT FOR VOTE (CDV)
PROJECT NUMBER:
IEC 61169-54/AMD1 ED2
DATE OF CIRCULATION: CLOSING DATE FOR VOTING:
2025-07-18 2025-10-10
SUPERSEDES DOCUMENTS:
46F/705/RR
IEC SC 46F : RF AND MICROWAVE PASSIVE COMPONENTS
SECRETARIAT: SECRETARY:
United States of America Mr John Morelli
OF INTEREST TO THE FOLLOWING COMMITTEES: HORIZONTAL FUNCTION(S):

ASPECTS CONCERNED:
SUBMITTED FOR CENELEC PARALLEL VOTING NOT SUBMITTED FOR CENELEC PARALLEL VOTING
Attention IEC-CENELEC parallel voting
The attention of IEC National Committees, members of CENELEC,
is drawn to the fact that this Committee Draft for Vote (CDV) is
submitted for parallel voting.
The CENELEC members are invited to vote through the CENELEC
online voting system.
This document is still under study and subject to change. It should not be used for reference purposes.
Recipients of this document are invited to submit, with their comments, notification of any relevant patent rights of which they are aware
and to provide supporting documentation.
Recipients of this document are invited to submit, with their comments, notification of any relevant “In Some Countries” clau ses to be
included should this proposal proceed. Recipients are reminded that the CDV stage is the final stage for submitting ISC c lauses. (SEE
AC/22/2007 OR NEW GUIDANCE DOC).

TITL
...