EN 60034-18-42:2017/A1:2020
(Amendment)Rotating electrical machines - Part 18-42: Partial discharge resistant electrical insulation systems (Type II) used in rotating electrical machines fed from voltage converters - Qualification tests
Rotating electrical machines - Part 18-42: Partial discharge resistant electrical insulation systems (Type II) used in rotating electrical machines fed from voltage converters - Qualification tests
Drehende elektrische Maschinen - Teil 18-42: Teilentladungsresistente Isoliersysteme (Typ II) von drehenden elektrischen Maschinen, die von Spannungsumrichtern gespeist werden - Qualifizierungsprüfungen
Machines électriques tournantes - Partie 18-42: Systèmes d'isolation électrique résistants aux décharges partielles (Type II) utilisés dans des machines électriques tournantes alimentées par convertisseurs de tension - Essais de qualification
Električni rotacijski stroji - 18-42. del: Električni izolacijski sistemi, odporni proti delni razelektritvi (tip II), ki se uporabljajo v električnih rotacijskih strojih, napajanih z napetostnimi pretvorniki - Preskusi zahtevanih pogojev (IEC 60034-18-42:2017/A1:2020)
General Information
Relations
Standards Content (Sample)
SLOVENSKI STANDARD
01-februar-2021
Električni rotacijski stroji - 18-42. del: Električni izolacijski sistemi, odporni proti
delni razelektritvi (tip II), ki se uporabljajo v električnih rotacijskih strojih,
napajanih z napetostnimi pretvorniki - Preskusi zahtevanih pogojev (IEC 60034-18-
42:2017/A1:2020)
Rotating electrical machines - Part 18-42: Partial discharge resistant electrical insulation
systems (Type II) used in rotating electrical machines fed from voltage converters -
Qualification tests (IEC 60034-18-42:2017/A1:2020)
Drehende elektrische Maschinen - Teil 18-42: Teilentladungsresistente Isoliersysteme
(Typ II) von drehenden elektrischen Maschinen, die von Spannungsumrichtern gespeist
werden - Qualifizierungsprüfungen (IEC 60034-18-42:2017/A1:2020)
Machines électriques tournantes - Partie 18-42: Systèmes d'isolation électrique
résistants aux décharges partielles (Type II) utilisés dans des machines électriques
tournantes alimentées par convertisseurs de tension - Essais de qualification (IEC 60034
-18-42:2017/A1:2020)
Ta slovenski standard je istoveten z: EN 60034-18-42:2017/A1:2020
ICS:
29.080.30 Izolacijski sistemi Insulation systems
29.160.01 Rotacijski stroji na splošno Rotating machinery in
general
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
EUROPEAN STANDARD EN 60034-18-42:2017/A1
NORME EUROPÉENNE
EUROPÄISCHE NORM
October 2020
ICS 29.160.01
English Version
Rotating electrical machines - Part 18-42: Partial discharge
resistant electrical insulation systems (Type II) used in rotating
electrical machines fed from voltage converters - Qualification
tests
(IEC 60034-18-42:2017/A1:2020)
Machines électriques tournantes - Partie 18-42: Systèmes Drehende elektrische Maschinen - Teil 18-42:
d'isolation électrique résistants aux décharges partielles Teilentladungsresistente Isoliersysteme (Typ II) von
(Type II) utilisés dans des machines électriques tournantes drehenden elektrischen Maschinen, die von
alimentées par convertisseurs de tension - Essais de Spannungsumrichtern gespeist werden -
qualification Qualifizierungsprüfungen
(IEC 60034-18-42:2017/A1:2020) (IEC 60034-18-42:2017/A1:2020)
This amendment A1 modifies the European Standard EN 60034-18-42:2017; it was approved by CENELEC on 2020-09-22. CENELEC
members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this amendment the
status of a national standard without any alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC
Management Centre or to any CENELEC member.
This amendment exists in three official versions (English, French, German). A version in any other language made by translation under the
responsibility of a CENELEC member into its own language and notified to the CEN-CENELEC Management Centre has the same status as
the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic,
Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the
Netherlands, Norway, Poland, Portugal, Republic of North Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland,
Turkey and the United Kingdom.
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
CEN-CENELEC Management Centre: Rue de la Science 23, B-1040 Brussels
© 2020 CENELEC All rights of exploitation in any form and by any means reserved worldwide for CENELEC Members.
Ref. No. EN 60034-18-42:2017/A1:2020 E
European foreword
The text of document 2/1998/FDIS, future IEC 60034-18-42/A1, prepared by IEC/TC 2 "Rotating
machinery" was submitted to the IEC-CENELEC parallel vote and approved by CENELEC as
The following dates are fixed:
• latest date by which the document has to be implemented at national (dop) 2021-06-22
level by publication of an identical national standard or by endorsement
• latest date by which the national standards conflicting with the (dow) 2023-09-22
document have to be withdrawn
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. CENELEC shall not be held responsible for identifying any or all such patent rights.
Endorsement notice
The text of the International Standard IEC 60034-18-42:2017/A1:2020 was approved by CENELEC as
a European Standard without any modification.
IEC 60034-18-42 ®
Edition 1.0 2020-08
INTERNATIONAL
STANDARD
NORME
INTERNATIONALE
A MENDMENT 1
AM ENDEMENT 1
Rotating electrical machines –
Part 18-42: Partial discharge resistant electrical insulation systems (Type II)
used in rotating electrical machines fed from voltage converters – Qualification
tests
Machines électriques tournantes –
Partie 18-42: Systèmes d’isolation électrique résistants aux décharges partielles
(Type II) utilisés dans des machines électriques tournantes alimentées par
convertisseurs de tension – Essais de qualification
INTERNATIONAL
ELECTROTECHNICAL
COMMISSION
COMMISSION
ELECTROTECHNIQUE
INTERNATIONALE
ICS 29.160.01 ISBN 978-2-8322-8603-6
– 2 – IEC 60034-18-42:2017/AMD1:2020
© IEC 2020
FOREWORD
This amendment has been prepared by IEC Technical Committee 2: Rotating machinery.
The text of this amendment is based on the following documents:
FDIS Report on voting
2/1998/FDIS 2/2008/RVD
Full information on the voting for the approval of this amendment can be found in the report on
voting indicated in the above table.
The committee has decided that the contents of this publication will remain unchanged until the
stability date indicated on the IEC website under "http://webstore.iec.ch" in the data related to
the specific publication. At this date, the publication will be
• reconfirmed,
• withdrawn,
• replaced by a revised edition, or
• amended.
_____________
3 Terms and definitions
Replace the existing definitions with the following new definitions:
3.11
impulse voltage repetition rate
f
average of the inverse of the time between two successive impulses of the same polarity,
whether unipolar or bipolar, in a considered set of pulses, for example for one period
3.18
impulse voltage insulation class for Type II insulation systems
IVIC
peak to peak voltage classes 1, 2, 3, 4, 5, 6, 7, S including certain time parameters for reliable
operation, assigned by the manufacturer in relation to the rated voltage for a specified
converter-driven machine and indicated in its documentation and, if applicable, on its rating
plate
3.29
maximum allowable peak to peak phase to ground voltage
U
IVIC
maximum allowable peak to peak phase to ground voltage in service, according to the IVIC-
specification
IEC 60034-18-42:2017/AMD1:2020 – 3 –
© IEC 2020
Add the following new definition:
3.30
test voltage factor
TVF
maximum allowable peak to peak operating phase-ground-voltages in units of U , divided by
N
2√2
Replace the existing Table 1 with the following:
Table 1 – Examples of the measured values of the characteristics
of the terminal voltages for two converter-fed machines
Machine rating 3,3 kV 6,6 kV
Measured peak to peak voltage on the phase to ground insulation 7,9 kV 13,9 kV
Fundamental frequency 50/60 Hz 50/60 Hz
Impulse rise time at the motor terminals 1 µs 3 µs
Impulse repetition rate 1 kHz 900 Hz
IVIC required to qualify the insulation for this service (see Table D.2, column 2) 3 2
Replace the second paragraph below Table 1 with the following:
The maximum change in voltage or jump voltage (U ) at the impulse repetition rate is shown in
j
Figure 3. This parameter is important in defining the voltage enhancement that can occur across
the first or last coil in the winding. A fundamental frequent double jump transition
(Figure 3, U )) is possible and needs to be considered accordingly.
j max
– 4 – IEC 60034-18-42:2017/AMD1:2020
© IEC 2020
Replace Figure 3 with the following:
Figure 3 – Jump voltage (U or U ) at the terminals
j j max
of a machine fed from a converter drive
10.2 Test methods
Replace the fist paragraph with the following:
The purpose of testing is to show that the electrical life
...
Questions, Comments and Discussion