Radio-frequency connectors - Part 10: Sectional specification for RF coaxial connectors with inner diameter of outer conductor 3 mm (0,12 in) with snap-on coupling - Characteristic impedance 50 Ω (Type SMB)

IEC 61169-10:2024, which is a sectional specification (SS), provides information and rules for the preparation of detail specifications (DS) for series SMB RF coaxial connectors with snap-on coupling with a characteristic impedance of 50 Ω. This document prescribes mating face dimensions for high performance connectors – grade 2, dimensional details of standard test connectors − grade 0, gauging information and tests selected from IEC 61169-1, applicable to all detail specifications relating to series SMB RF connectors. This document indicates recommended performance characteristics to be considered when writing a detail specification and it covers test schedules and inspection requirements for assessment levels M and H. The series SMB connectors are used to connect with all kinds of RF cables and microstrips in microwave transmission systems. The operating frequency is up to 4 GHz.

Hochfrequenz-Steckverbinder - Teil 10: Hochfrequenz-Koaxialsteckverbinder mit einem Innen-/Außenleiterdurchmesser von 3 mm (0,12 Zoll) mit Schnappkupplung - Wellenwiderstand 50 Ω (Typ SMB)

Connecteurs pour fréquences radioélectriques - Partie 10: Spécification intermédiaire relative aux connecteurs coaxiaux pour fréquences radioélectriques avec diamètre intérieur du conducteur extérieur de 3 mm (0,12 in) à couplage par encliquetage - Impédance caractéristique 50 Ω (type SMB)

l’IEC 61169-10:2024, qui est une spécification générique (SS - sectional specification), fournit les informations et règles applicables en vue de l'établissement de spécifications particulières (DS - detail specification) pour les connecteurs coaxiaux pour fréquences radioélectriques série SMB à couplage par encliquetage avec une impédance caractéristique de 50 Ω. Le présent document prescrit les dimensions de la face d'accouplement pour les connecteurs à haute performance de grade 2, les détails dimensionnels des connecteurs d'essai normalisés de grade 0 ainsi que des informations concernant les calibres et les essais tirés de l’IEC 61169‑1, applicables à toutes les spécifications particulières relatives aux connecteurs pour fréquences radioélectriques de série SMB. Le présent document indique les caractéristiques de performance recommandées à prendre en considération lors de la rédaction d'une spécification particulière et il couvre les des programmes d'essai et les exigences de contrôle à l'égard des niveaux d’assurance de la qualité M et H. Les connecteurs de série SMB sont utilisés avec tout type de câbles pour fréquences radioélectriques et de microrubans dans les systèmes de transmission à hyperfréquences. La fréquence de fonctionnement va jusqu'à 4 GHz.

Radiofrekvenčni konektorji - 10. del: Področna specifikacija za radiofrekvenčne (RF) koaksialne konektorje z notranjim premerom zunanjega vodnika 3 mm (0.12 in) in navojnim spajanjem - Karakteristična impedanca 50 ohmov (tip SMB) (IEC 61169-10:2024)

Standard IEC 61169-10:2024, ki je področna specifikacija (SS), podaja informacije in določa pravila za pripravo podrobnih specifikacij (DS) za radiofrekvenčne (RF) koaksialne konektorje serije SMB z navojnim spajanjem s karakteristično impedanco 50 Ω.
Ta dokument predpisuje mere spojne površine za konektorje visoke zmogljivosti razreda 2, podrobnosti o merah standardnih preskusnih konektorjev tipa 0, merjenje informacij in preskuse, izbrane iz standarda IEC 61169-1, ki se uporabljajo za vse podrobne specifikacije v zvezi z radiofrekvenčnimi konektorji serije SMB.
Ta dokument navaja priporočene lastnosti, ki jih je treba upoštevati pri sestavljanju podrobne specifikacije, ter zajema razporede preskusov in zahteve za pregled za ravni vrednotenja M in H.
Konektorji serije SMB se uporabljajo za povezavo z različnimi radiofrekvenčnimi kabli in mikrotrakovi v mikrovalovnih prenosnih sistemih. Frekvenčno območje delovanja je največ 4 GHz.

General Information

Status
Published
Publication Date
28-Mar-2024
Current Stage
6060 - Document made available - Publishing
Start Date
29-Mar-2024
Due Date
31-Aug-2023
Completion Date
29-Mar-2024

Buy Standard

Standard
EN IEC 61169-10:2024
English language
28 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)


SLOVENSKI STANDARD
01-junij-2024
Radiofrekvenčni konektorji - 10. del: Področna specifikacija za radiofrekvenčne
(RF) koaksialne konektorje z notranjim premerom zunanjega vodnika 3 mm (0.12
in) in navojnim spajanjem - Karakteristična impedanca 50 ohmov (tip SMB) (IEC
61169-10:2024)
Radio-frequency connectors - Part 10: Sectional specification for RF coaxial connectors
with inner diameter of outer conductor 3 mm (0,12 in) with snap-on coupling -
Characteristic impedance 50 Ω (Type SMB) (IEC 61169-10:2024)
Hochfrequenz-Steckverbinder – Teil 10: Hochfrequenz-Koaxialsteckverbinder mit einem
Innen-/Außenleiterdurchmesser von 3 mm (0,12 Zoll) mit Schnappkupplung -
Wellenwiderstand 50 Ohm (Typ SMB) (IEC 61169-10:2024)
Connecteurs pour fréquences radioélectriques. Dixième partie: Connecteurs coaxiaux
pour fréquences radioélectriques avec diamètre intérieur du conducteur extérieur de 3
mm (0,12 in) à accouplement par encliquetage - Impédance caractéristique 50 ohms
(type SMB) (IEC 61169-10:2024)
Ta slovenski standard je istoveten z: EN IEC 61169-10:2024
ICS:
33.120.30 Radiofrekvenčni konektorji RF connectors
(RF)
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

EUROPEAN STANDARD EN IEC 61169-10

NORME EUROPÉENNE
EUROPÄISCHE NORM March 2024
ICS 33.120.30
English Version
Radio-frequency connectors - Part 10: Sectional specification for
RF coaxial connectors with inner diameter of outer conductor 3
mm (0,12 in) with snap-on coupling - Characteristic impedance
50 Ω (Type SMB)
(IEC 61169-10:2024)
Connecteurs pour fréquences radioélectriques - Partie 10: Hochfrequenz-Steckverbinder - Teil 10: Hochfrequenz-
Spécification intermédiaire relative aux connecteurs Koaxialsteckverbinder mit einem Innen-
coaxiaux pour fréquences radioélectriques avec diamètre /Außenleiterdurchmesser von 3 mm (0,12 Zoll) mit
intérieur du conducteur extérieur de 3 mm (0,12 in) à Schnappkupplung - Wellenwiderstand 50 Ohm (Typ SMB)
couplage par encliquetage - Impédance caractéristique (IEC 61169-10:2024)
50 Ω (type SMB)
(IEC 61169-10:2024)
This European Standard was approved by CENELEC on 2024-03-28. CENELEC members are bound to comply with the CEN/CENELEC
Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC
Management Centre or to any CENELEC member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation
under the responsibility of a CENELEC member into its own language and notified to the CEN-CENELEC Management Centre has the
same status as the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic,
Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the
Netherlands, Norway, Poland, Portugal, Republic of North Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland,
Türkiye and the United Kingdom.

European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
CEN-CENELEC Management Centre: Rue de la Science 23, B-1040 Brussels
© 2024 CENELEC All rights of exploitation in any form and by any means reserved worldwide for CENELEC Members.
Ref. No. EN IEC 61169-10:2024 E

European foreword
The text of document 46F/658/FDIS, future edition 1 of IEC 61169-10, prepared by SC 46F "RF and
microwave passive components" of IEC/TC 46 "Cables, wires, waveguides, RF connectors, RF and
microwave passive components and accessories" was submitted to the IEC-CENELEC parallel vote
and approved by CENELEC as EN IEC 61169-10:2024.
The following dates are fixed:
• latest date by which the document has to be implemented at national (dop) 2024-12-28
level by publication of an identical national standard or by endorsement
• latest date by which the national standards conflicting with the (dow) 2027-03-28
document have to be withdrawn
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. CENELEC shall not be held responsible for identifying any or all such patent rights.
Any feedback and questions on this document should be directed to the users’ national committee. A
complete listing of these bodies can be found on the CENELEC website.
Endorsement notice
The text of the International Standard IEC 61169-10:2024 was approved by CENELEC as a European
Standard without any modification.
Annex ZA
(normative)
Normative references to international publications
with their corresponding European publications
The following documents are referred to in the text in such a way that some or all of their content
constitutes requirements of this document. For dated references, only the edition cited applies. For
undated references, the latest edition of the referenced document (including any amendments)
applies.
NOTE 1 Where an International Publication has been modified by common modifications, indicated by (mod), the
relevant EN/HD applies.
NOTE 2 Up-to-date information on the latest versions of the European Standards listed in this annex is available
here: www.cencenelec.eu.
Publication Year Title EN/HD Year
IEC 61169-1 2013 Radio frequency connectors - Part 1: EN 61169-1 2013
Generic specification - General
requirements and measuring methods
IEC 62153-4-7 - Metallic cables and other passive EN IEC 62153-4-7 -
components test methods - Part 4-7:
Electromagnetic compatibility (EMC) - Test
method for measuring of transfer
impedance Z and screening attenuation
T
aS or coupling attenuation aC of connectors
and assemblies - Triaxial tube in tube
method
IEC 61169-10 ®
Edition 1.0 2024-02
INTERNATIONAL
STANDARD
NORME
INTERNATIONALE
Radio- frequency connectors –
Part 10: Sectional specification for RF coaxial connectors with inner diameter of

outer conductor 3 mm (0,12 in) with snap-on coupling – Characteristic

impedance 50 Ω (Type SMB)
Connecteurs pour fréquences radioélectriques –

Partie 10: Spécification intermédiaire relative aux connecteurs coaxiaux pour

fréquences radioélectriques avec diamètre intérieur du conducteur extérieur de

3 mm (0,12 in) à couplage par encliquetage – Impédance caractéristique 50 Ω

(type SMB)
INTERNATIONAL
ELECTROTECHNICAL
COMMISSION
COMMISSION
ELECTROTECHNIQUE
INTERNATIONALE
ICS 33.120.30  ISBN 978-2-8322-8277-9

– 2 – IEC 61169-10:2024 © IEC 2024
CONTENTS
FOREWORD . 3
1 Scope . 5
2 Normative references . 5
3 Terms and definitions . 5
4 Mating face and gauge information . 6
4.1 Dimensions − General connectors – Grade 2 . 6
4.1.1 Connector with pin centre contact . 6
4.1.2 Connector with socket centre contact . 7
4.2 Gauges . 9
4.2.1 Gauge pin for socket centre contact. 9
4.2.2 Gauge for outer contact of connector with pin centre contact . 9
4.3 Dimensions – Standard test connectors – Grade 0 . 11
4.3.1 Connectors with pin centre contact . 11
4.3.2 Connector with socket centre contact . 12
5 Quality assessment procedures . 14
5.1 General . 14
5.2 Ratings and characteristics . 14
5.3 Test schedule and inspection requirements. 17
5.3.1 Acceptance tests . 17
5.3.2 Periodic tests . 17
5.3.3 Procedures for the quality conformance . 20
6 Instructions for preparation of detail specifications . 20
6.1 General . 20
6.2 Identification of the component . 20
6.3 Performance . 20
6.4 Marking, ordering information and related matters . 21
6.5 Selection of tests, test conditions and severities . 21
6.6 Blank detail specification pro-forma for SMB connectors . 21

Figure 1 – Connector with pin centre contact . 6
Figure 2 – Connector with socket centre contact . 8
Figure 3 – Gauge pin for socket centre contact . 9
Figure 4 – Gauge for outer contact of connector with pin centre contact . 10
Figure 5 – Connector with pin centre contact . 11
Figure 6 – Connector with socket in centre contact . 13

Table 1 – Dimensions of connector with pin centre contact . 7
Table 2 – Dimensions of connector with socket centre contact . 8
Table 3 – Dimensions of gauge pin for socket centre contact . 9
Table 4 – Dimensions of gauge for outer contact of connector with pin centre contact . 10
Table 5 – Dimensions of connector with pin centre contact . 12
Table 6 – Dimensions of connector with socket centre contact . 14
Table 7 – Preferred climatic categories . 15
Table 8 – Ratings and characteristics . 15
Table 9 – Acceptance tests . 17
Table 10 – Periodic tests . 18

IEC 61169-10:2024 © IEC 2024 – 3 –
INTERNATIONAL ELECTROTECHNICAL COMMISSION
____________
RADIO-FREQUENCY CONNECTORS –
Part 10: Sectional specification for RF coaxial connectors with inner
diameter of outer conductor 3 mm (0,12 in) with snap-on coupling –
Characteristic impedance 50 Ω (Type SMB)

FOREWORD
1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of IEC is to promote international
co-operation on all questions concerning standardization in the electrical and electronic fields. To this end and
in addition to other activities, IEC publishes International Standards, Technical Specifications, Technical Reports,
Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC Publication(s)”). Their
preparation is entrusted to technical committees; any IEC National Committee interested in the subject dealt with
may participate in this preparatory work. International, governmental and non-governmental organizations liaising
with the IEC also participate in this preparation. IEC collaborates closely with the International Organization for
Standardization (ISO) in accordance with conditions determined by agreement between the two organizations.
2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international
consensus of opinion on the relevant subjects since each technical committee has representation from all
interested IEC National Committees.
3) IEC Publications have the form of recommendations for international use and are accepted
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.