EN 50117-4-1:2008
(Main)Coaxial cables - Part 4-1: Sectional specification for cables for BCT cabling in accordance with EN 50173 - Indoor drop cables for systems operating at 5 MHz - 3 000 MHz
Coaxial cables - Part 4-1: Sectional specification for cables for BCT cabling in accordance with EN 50173 - Indoor drop cables for systems operating at 5 MHz - 3 000 MHz
This sectional specification relates to EN 50117-1: Generic specification for coaxial cables, and is to be read in conjunction with this generic standard. This specification applies to coaxial cables for BCT-cabling in accordance with EN 50173 operating at a maximum d.c. voltage of 72 V and a maximum d.c. current of 0,5 A at a temperature range between –20 °C and +60 °C 1) and at frequencies between 5 MHz and 3 000 MHz and complying with the requirements of EN 50083. The purpose of this European Standard is to specify the applicable test methods and requirements for the electrical, mechanical, and environmental and fire performance of the cables.
Koaxialkabel - Teil 4-1: Rahmenspezifikation für Kabel für RuK-Verkabelung nach EN 50173 - Hausinstallationskabel im Bereich von 5 MHz bis 3 000 MHz
Diese Rahmenspezifikation bezieht sich auf EN 50117-1: Fachgrundspezifikation für Koaxialkabel und ist in Verbindung mit dieser Fachgrundspezifikation zu lesen. Die vorliegende Spezifikation bezieht sich auf Koaxialkabel für RuK-Verkabelung in Übereinstimmung mit EN 50173 mit einer maximalen Betriebsspannung von 72 V und einem maximalen Gleichstrom von 0,5 A im Temperaturbereich von - 20 °C bis +60 °C 1), welche im Frequenzbereich zwischen 5 MHz und 3 000 MHz betrieben werden. Die vorliegende Spezifikation stimmt mit den Anforderungen der EN 50083 überein. Zweck dieser Europäischen Norm ist, die zutreffenden Prüfverfahren und Anforderungen der elektrischen und mechanischen Eigenschaften der Kabel sowie das Verhalten der Kabel gegenüber Umgebungsbedingungen und das Brandverhalten festzulegen.
Câbles coaxiaux - Partie 4-1: Spécification intermédiaire pour câbles destinés au câblage BCT (Broadcast and Communication Technology) conformément à la EN 50173 - Câbles de raccordement à usage intérieur pour systèmes fonctionnant dans la plage 5 MHz - 3 000 MHz
La présente spécification intermédiaire fait référence à la EN 50117-1: Spécification générique pour câbles coaxiaux, et est à lire conjointement à cette dernière norme générique. La présente spécification s’applique aux câbles coaxiaux destinés aux câblages BCT (Broadcast and Communication Technology), conformément à la EN 50173, fonctionnant à une tension continue maximale de 72 V et à un courant continu maximal de 0,5 A, sur une plage de températures comprise entre –20 °C et +60 °C 1) et à des fréquences comprises entre 5 MHz et 3 000 MHz, conformes aux exigences de la EN 50083. La présente Norme Européenne est destinée à spécifier les méthodes d’essai et les exigences applicables pour les performances électriques, mécaniques, environnementales et de tenue au feu des câbles.
Koaksialni kabli - 4-1. del: Področna specifikacija za kable za okabljenje BCT v skladu z EN 50173 - Notranji zaključni kabli za sisteme, ki delujejo v območju 5 MHz do 3.000 MHz
Ta področna specifikacija je povezana s standardom EN 50117-1: rodovna specifikacija koaksialnih kablov in jo je treba brati skupaj s tem rodovnim standardom. Ta specifikacija velja za koaksialne kable za okabljenje BCT v skladu s standardom EN 50173, ki delujejo pri največji napetosti enosmernega toka 72 V, največjem enosmernem toku 0,5 A, temperaturi med –20 °C in +60 °C 1) ter frekvencah med 5 MHz in 3 000 MHz in ustrezajo zahtevam standarda EN 50083. Namen tega evropskega standarda je določiti veljavne preskusne metode in zahteve za električne, mehanske, okoljske in požarne lastnosti kablov.
General Information
Relations
Standards Content (Sample)
SLOVENSKI STANDARD
01-oktober-2008
.RDNVLDOQLNDEOLGHO3RGURþQDVSHFLILNDFLMD]DNDEOH]DRNDEOMHQMH%&7Y
VNODGX](11RWUDQML]DNOMXþQLNDEOL]DVLVWHPHNLGHOXMHMRYREPRþMX
0+]GR0+]
Coaxial cables -- Part 4-1: Sectional specification for cables for BCT cabling in
accordance with EN 50173 - Indoor drop cables for systems operating at 5 MHz - 3 000
MHz
Koaxialkabel - Teil 4-1: Rahmenspezifikation für Kabel für RuK-Verkabelung nach EN
50173 - Hausinstallationskabel im Bereich von 5 MHz bis 3 000 MHz
Câbles coaxiaux -- Partie 4-1: Spécification intermédiaire pour câbles destinés au
câblage BCT (Broadcast and Communication Technology) conformément à la EN 50173
- Câbles de raccordement à usage intérieur pour systèmes fonctionnant dans la plage 5
MHz - 3 000 MHz
Ta slovenski standard je istoveten z: EN 50117-4-1:2008
ICS:
33.120.10 Koaksialni kabli. Valovodi Coaxial cables. Waveguides
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
EUROPEAN STANDARD
EN 50117-4-1
NORME EUROPÉENNE
August 2008
EUROPÄISCHE NORM
ICS 33.120.10
English version
Coaxial cables -
Part 4-1: Sectional specification for cables for BCT cabling
in accordance with EN 50173 -
Indoor drop cables for systems
operating at 5 MHz - 3 000 MHz
Câbles coaxiaux - Koaxialkabel -
Partie 4-1: Spécification intermédiaire Teil 4-1: Rahmenspezifikation
pour câbles destinés au câblage BCT für Kabel für RuK-Verkabelung
(Broadcast and Communication Technology) nach EN 50173 -
conformément à la EN 50173 - Hausinstallationskabel
Câbles de raccordement à usage intérieur im Bereich von 5 MHz bis 3 000 MHz
pour systèmes fonctionnant d
ans la plage 5 MHz - 3 000 MHz
This European Standard was approved by CENELEC on 2008-04-01. CENELEC members are bound to comply
with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard
the status of a national standard without any alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on
application to the Central Secretariat or to any CENELEC member.
This European Standard exists in three official versions (English, French, German). A version in any other
language made by translation under the responsibility of a CENELEC member into its own language and notified
to the Central Secretariat has the same status as the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Cyprus, the
Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia,
Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain,
Sweden, Switzerland and the United Kingdom.
CENELEC
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
Central Secretariat: rue de Stassart 35, B - 1050 Brussels
© 2008 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.
Ref. No. EN 50117-4-1:2008 E
Foreword
This European Standard was prepared by SC 46XA, Coaxial cables, of Technical Committee CENELEC
TC 46X, Communication cables.
The text of the draft was submitted to the Unique Acceptance Procedure and was approved by CENELEC
as EN 50117-4-1 on 2008-04-01.
This standard is to be read in conjunction with EN 50117-1:2002.
The following dates were fixed:
– latest date by which the EN has to be implemented
at national level by publication of an identical
national standard or by endorsement (dop) 2009-04-01
– latest date by which the national standards conflicting
with the EN have to be withdrawn (dow) 2011-04-01
__________
- 3 - EN 50117-4-1:2008
Contents
1 Scope . 4
2 Normative references . 4
3 Definitions . 5
4 Requirements for cable construction . 5
4.1 General . 5
4.2 Inner conductor . 5
4.3 Dielectric . 5
4.4 Outer conductor or screen . 5
4.5 Filling c o m pounds . 5
4.6 Moisture barriers . 5
4.7 Wrapping layers . 6
4.8 Sheath . 6
4.9 Metallic protection . 6
4.10 Cable integral suspension strand (messenger wire) . 6
4.11 Oversheath . 6
4.12 Fauna proofing . 6
4.13 Chemical and/or environmental proofing . 6
4.14 Cable identification . 6
5 Tests for completed cables . 7
5.1 Electrical tests . 7
5.2 Mechanical tests . 10
5.3 Environmental tests . 11
5.4 Fire performance test methods (FFS) . 12
Tables
Table 1 – Low-frequency and d.c. electrical measurements . 7
Table 2 – High-frequency electrical and transmission measurements . 8
Table 3 – Mechanical tests . 10
Table 4 – Environmental tests . 11
1 Scope
This sectional specification relates to EN 50117-1: Generic specification for coaxial cables, and is
to be read in conjunction with this generic standard. This specification applies to coaxial cables for
BCT-cabling in accordance with EN 50173 operating at a maximum d.c. voltage of 72 V and a
1)
maximum d.c. current of 0,5 A at a temperature range between –20 °C and +60 °C and at
frequencies between 5 MHz and 3 000 MHz and complying with the requirements of EN 50083.
The purpose of this European Standard is to specify the applicable test methods and
requirements for the electrical, mechanical, and environmental and fire performance of the cables.
2 Normative references
The following referenced documents are indispensable for the application of this document. For
dated references, only the edition cited applies. For undated references, the latest edition of the
referenced document (including any amendments) applies.
EN 50083 series Cable networks for television signals, sound signals and interactive services
EN 50117-1:2002 Coaxial cables - Part 1: Generic specification
EN 50173-1 Information technology - Generic cabling systems - Part 1: General requirements
EN 50173-4 Information technology - Generic cabling systems - Part 4: Homes
EN 50289-1-6:2002 Communication cables - Specifications for test methods -
Part 1-6: Electrical test methods - Electromagnetic performance
EN 50289-3-9:2001 Communication cables - Specifications for test methods -
Part 3-9: Mechanical test methods - Bending tests
EN 50290-1-2 Communication cables - Part 1-2: Definitions
EN 50290-2-22 Communication cables - Part 2-22: Common design rules and construction -
PVC sheathing compounds
EN 50290-2-23 Communication cables - Part 2-23: Common design rules and construction -
PE insulation
EN 50290-2-25 Communication cables - Part 2-25: Common design rules and construction -
Polypropylene insulation compounds
EN 50290-2-27 Communication cables - Part 2-27: Common design rules and construction -
Halogen free flame retardant thermoplastic sheathing compounds
EN 50290-4-1 Communication cables - Part 4-1: General considerations for the use of cables -
Environmental conditions and safety aspects
EN 50356 Method for spark testing of cables
EN 62153-1-1 Metallic communication cables test methods - Part 1-1: Electrical - Measurement
of the pulse/step return loss in the frequency domain using the Inverse Discrete
Fourier Transformation (IDFT) (IEC 62153-1-1)
EN 62230 Electric cables - Spark-test method (IEC 62230)
IEC 61196-1-115 Coaxial communication cables - Part 1-115: Electrical test methods - Test for
regularity of impedance (pulse/step function return loss)
1)
Only valid without current load.
- 5 - EN 50117-4-1:2008
3 Definitions
For the purposes of this document, the terms and definitions of EN 50290-1-2 and EN 50117-1
apply.
4 Requirements for cable construction
4.1 General
Designing the cable, consideration should be paid to the maximum admissible current stated in
the detail specification. It is assumed that the raise of temperature of the inner conductor when
submitted to the maximum current under nominal ambient conditions does not affect the
mechanical and electrical properties of the cable (details are under study).
This specification covers standard applications. Other cables may be designed with respect to the
MICE table depending upon agreement between customer and supplier.
4.2 Inner conductor
The conductor shall meet the requirements of EN 50117-1, 4.2, and shall be solid. Individual wires
can be plain or metal coated. Dimensions shall be ≥ 0,6 mm and ≤ 1,2 mm and specified in the
detail specification.
There shall be no joint made subsequent to the last drawing operation.
4.3 Dielectric
The dielectric material(s) shall be in accordance with EN 50117-1, 4.3 and shall consist of
polyolefin materials, with EN 50290-2-23 (polyethylene), EN 50290-2-25 (polypropylene) or shall
comply with any relevant part of EN 50290-2 series.
The diameter of the dielectric shall be ≥ 3,0 mm and ≤ 6,0 mm and shall be specified in the detail
specification
4.4 Outer conductor or screen
The construction and material of the outer conductor and/or screen shall meet the requirements of
EN 50117-1, 4.4, b), c), f) or g). Where option b) is used, a double braid layer is required.
For braid constructions or helically wound wires, the braid angle shall be between 15° and 45°.
The coverage factor shall be greater than or equal to 65 %, or, when the cable is provided with a
metal foil, greater than or equal to 25 %. These values are also valid for cables with two bi-
directional layers of helically wound wires.
The diameter over the outer conductor shall be ≥ 3,5 mm and ≤ 6,5 mm and specified in the detail
specification.
4.5 Filling compounds
Not applicable.
4.6 Moisture barriers
Not applicable.
4.7 Wrapping layers
Not applicable.
4.8 Sheath
Sheath material(s) shall meet the requirements of EN 50290-2-22 for PVC sheaths or
EN 50290-2-27 for halogen free flame retardant materials.
The sheath shall also meet the requirements of EN 50117-1, 4.8.
The diameter over the outer sheath shall ≤ 11,0 mm and specified in the detail specification.
4.9 Metallic protection
Not applicable.
4.10 Cable integral suspension strand (messenger wire)
Not applicable.
4.11 Oversheath
Not applicable.
4.12 Fauna proofing
Not applicable.
4.13 Chemical and/or environmental proofing
Not applicable.
4.14 Cable identification
Cable identification shall be in accordance with EN 50117-1, 4.14.
4.14.1 Sheath marking
Unless otherwise specified in the detail specification sheath marking shall be achieved as a
non-degradable print containing the following minimum information:
– designation of the cable;
– attenuation value (in dB/100 m at 800 MHz, rounded);
– screening class;
– Euro-class;
– name of supplier.
EXAMPLE EN 50117-4-1 21 < XXX > Class B Euro-class C < YYY >
NOTE The Construction product directive (CPD) will define classes for the fire performance of cables. As long as the CPD is
under consideration and fire performance classes (Euroclasses) are not defined, sheath marking with Euroclass is not required.
- 7 - EN 50117-4-1:2008
4.14.2 Labelling
Unless otherwise specified in the detail specification drums or coils shall be provided with a label with a
non-degradable print containing the following minimum information:
– designation of the cable;
– attenuation value (in dB/100 m at 800 MHz, rounded);
– screening class;
– Euro-class;
– name of supplier;
– batch part number;
– length of cable.
EXAMPLE
...