EN 50530:2010
(Main)Overall efficiency of grid connected photovoltaic inverters
Overall efficiency of grid connected photovoltaic inverters
This European Standard provides a procedure for the measurement of the efficiency of the maximum power point tracking (MPPT) of inverters, which are used in grid-connected photovoltaic systems. In that case the inverter energizes a low voltage grid with rated AC voltage and rated frequency. Both the static and dynamic MPPT efficiency is considered. Based on the static MPPT efficiency and conversion efficiency the overall inverter efficiency is calculated. The dynamic MPPT efficiency is indicated separately.
Gesamtwirkungsgrad von Photovoltaik-Wechselrichtern
Efficacité globale des onduleurs photovoltaïques raccordés au réseau
La présente Norme Européenne fournit une procédure de mesure de l’efficacité de la conversion optimale d’énergie (MPPT – Maximum Power Point Tracking en anglais) des onduleurs, qui sont utilisés dans des systèmes photovoltaïques raccordés au réseau. Dans ce cas, l'onduleur alimente un réseau basse tension avec une tension alternative assignée et une fréquence assignée. L'efficacité de la MPPT tant statique que dynamique est prise en considération. L'efficacité globale de l'onduleur est calculée en fonction de l'efficacité de la MPPT statique et de l'efficacité de la conversion. L'efficacité de la MPPT dynamique est indiquée séparément.
Celovita učinkovitost fotonapetostnih razsmernikov
Ta evropski standard zagotavlja postopek za merjenje učinkovitosti sledenja maksimalni moči (MPPT) razsmernikov, ki se uporabljajo v omrežju povezanih fotonapetostnih sistemov. V tem primeru razsmernik napaja nizkonapetostno omrežje z nazivno izmenično napetostjo in nazivno frekvenco. Upoštevani sta statična in dinamična učinkovitost MPPT. Na osnovi statične učinkovitosti MPPT in učinkovitosti pretvorbe se izračuna celovita učinkovitost razsmernika. Dinamična učinkovitost MPPT je prikazana ločeno.
General Information
Relations
Standards Content (Sample)
SLOVENSKI STANDARD
SIST EN 50530:2011
01-junij-2011
&HORYLWDXþLQNRYLWRVWIRWRQDSHWRVWQLKUD]VPHUQLNRY
Overall efficiency of photovoltaic inverters
Gesamtwirkungsgrad von Photovoltaik-Wechselrichtern
Rendement global des onduleurs photovoltaïques
Ta slovenski standard je istoveten z: EN 50530:2010
ICS:
27.160 6RQþQDHQHUJLMD Solar energy engineering
SIST EN 50530:2011 en,fr,de
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
---------------------- Page: 1 ----------------------
SIST EN 50530:2011
---------------------- Page: 2 ----------------------
SIST EN 50530:2011
EUROPEAN STANDARD
EN 50530
NORME EUROPÉENNE
April 2010
EUROPÄISCHE NORM
ICS 27.160
English version
Overall efficiency of grid connected photovoltaic inverters
Efficacité globale des onduleurs Gesamtwirkungsgrad von Photovoltaik-
photovoltaïques raccordés au réseau Wechselrichtern
This European Standard was approved by CENELEC on 2010-04-01. CENELEC members are bound to comply
with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard
the status of a national standard without any alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on
application to the Central Secretariat or to any CENELEC member.
This European Standard exists in three official versions (English, French, German). A version in any other
language made by translation under the responsibility of a CENELEC member into its own language and notified
to the Central Secretariat has the same status as the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus,
the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy,
Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia,
Spain, Sweden, Switzerland and the United Kingdom.
CENELEC
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
Management Centre: Avenue Marnix 17, B - 1000 Brussels
© 2010 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.
Ref. No. EN 50530:2010 E
---------------------- Page: 3 ----------------------
SIST EN 50530:2011
EN 50530:2010 – 2 –
Foreword
This European Standard was prepared by the Technical Committee CENELEC TC 82, Solar photovoltaic
energy systems. It was submitted to the Unique Acceptance Procedure and approved by CENELEC on
2010-04-01.
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. CEN and CENELEC shall not be held responsible for identifying any or all such patent
rights.
The following dates were fixed:
– latest date by which the EN has to be implemented
at national level by publication of an identical
national standard or by endorsement
(dop) 2011-04-01
– latest date by which the national standards conflicting
with the EN have to be withdrawn
(dow) 2013-04-01
__________
---------------------- Page: 4 ----------------------
SIST EN 50530:2011
– 3 – EN 50530:2010
Contents
1 Scope . 5
2 Normative references . 5
3 Terms and definitions . 5
3.1 Inverter input (PV generator) . 5
3.2 Inverter output (grid) . 6
3.3 Measured quantities . 6
3.4 Calculated quantities . 7
3.5 Other definitions . 8
4 MPPT efficiency . 8
4.1 General description . 8
4.2 Test set-up .
...
Questions, Comments and Discussion