Ultrasonics - Continuous-wave Doppler systems - Test procedures

Describes the test methods for measuring the performance of continuous-wave ultrasonic Doppler flowmeters, velocimeters, or foetal heart detectors and special Doppler test objects for determining various performance properties of Doppler ultrasound systems. Does not include electrical safety and acoustic output. This publication has the status of a type 2 technical report.

Ultraschall - Dauerschall Doppler System - Prüfverfahren

Ultrasons - Ensembles à effet Doppler à ondes entretenues - Méthodes d'essai

Décrit des méthodes d'essai pour mesurer les performances d'ensembles ultrasonores à effet Doppler à ondes entretenues pour la mesure des écoulements, des vitesses d'écoulement ou pour la détection des battements du coeur foetal et des montages spéciaux pour effet Doppler pour déterminer des propriétés diverses de fonctionnement d'ensembles ultrasonores à effet Doppler. La sécurité électrique et la sortie acoustique ne relèvent pas de ce rapport technique. Cette publication a le statut d'un rapport technique de type 2.

Ultrasonics - Continuous-wave Doppler systems - Test procedures (IEC 61206:1993)

General Information

Status
Published
Publication Date
12-Feb-1995
Withdrawal Date
14-Dec-1995
Technical Committee
Drafting Committee
Parallel Committee
Current Stage
6060 - Document made available - Publishing
Start Date
13-Feb-1995
Completion Date
13-Feb-1995

Overview

EN 61206:1995 (adopted as SIST EN 61206:2002) is a European technical report that defines test procedures for continuous-wave (CW) ultrasonic Doppler systems. It covers methods for measuring the performance of CW Doppler devices such as ultrasonic Doppler flowmeters, velocimeters and fetal heart detectors, and specifies the use of special Doppler test objects to determine various performance properties. This publication explicitly excludes electrical safety and acoustic output requirements and has the status of a type 2 technical report. EN 61206 is aligned with IEC 61206:1993.

Key topics

  • Scope of measurement: Test methods for performance evaluation of CW Doppler systems (flowmeters, velocimeters, fetal heart detectors).
  • Performance properties: Procedures to determine key functional characteristics (e.g., sensitivity, velocity detection, directional discrimination, signal stability and repeatability, and response to Doppler targets) - using standardized Doppler test objects.
  • Test objects: Description and use of special Doppler test objects (phantoms or mechanical simulators) for consistent, repeatable testing across devices.
  • Test procedures: Stepwise measurement approaches to collect comparable performance data for acceptance testing, calibration and R&D.
  • Limitations: Does not address electrical safety, acoustic output levels or other diagnostic-ultrasound-specific safety parameters.

Applications

  • Acceptance testing and commissioning of continuous-wave Doppler equipment in clinical and industrial settings.
  • Routine quality control and periodic performance verification in hospitals, clinics and diagnostic labs.
  • Product development, validation and production testing by manufacturers of CW Doppler flowmeters, velocimeters and fetal heart detectors.
  • Independent test laboratories performing objective performance evaluations and benchmarking.

Who uses this standard

  • Biomedical and clinical engineers responsible for device QA/QC.
  • Medical device manufacturers and R&D teams producing CW Doppler systems.
  • Calibration and test laboratories.
  • Quality managers and regulatory affairs professionals preparing device documentation for conformity assessment.

Related standards

  • IEC 61206:1993 (original international document, equivalent in scope).
  • Other IEC/EN standards covering ultrasound device safety and acoustic output (e.g., the IEC 60601 series for medical electrical equipment and diagnostic ultrasound safety/performance standards) - note EN 61206 does not replace electrical safety or acoustic-output requirements.

EN 61206 is essential for stakeholders who need reliable, repeatable procedures to evaluate the functional performance of continuous-wave Doppler ultrasound systems and to ensure consistent device behavior across deployments.

Standard
EN 61206:2002
English language
35 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)


SLOVENSKI STANDARD
01-september-2002
Ultrasonics - Continuous-wave Doppler systems - Test procedures (IEC
61206:1993)
Ultrasonics - Continuous-wave Doppler systems - Test procedures
Ultraschall - Dauerschall Doppler System - Prüfverfahren
Ultrasons - Ensembles à effet Doppler à ondes entretenues - Méthodes d'essai
Ta slovenski standard je istoveten z: EN 61206:1995
ICS:
11.040.50 Radiografska oprema Radiographic equipment
17.140.50 Elektroakustika Electroacoustics
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

-
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.

Loading comments...

Frequently Asked Questions

EN 61206:1995 is a standard published by CLC. Its full title is "Ultrasonics - Continuous-wave Doppler systems - Test procedures". This standard covers: Describes the test methods for measuring the performance of continuous-wave ultrasonic Doppler flowmeters, velocimeters, or foetal heart detectors and special Doppler test objects for determining various performance properties of Doppler ultrasound systems. Does not include electrical safety and acoustic output. This publication has the status of a type 2 technical report.

Describes the test methods for measuring the performance of continuous-wave ultrasonic Doppler flowmeters, velocimeters, or foetal heart detectors and special Doppler test objects for determining various performance properties of Doppler ultrasound systems. Does not include electrical safety and acoustic output. This publication has the status of a type 2 technical report.

EN 61206:1995 is classified under the following ICS (International Classification for Standards) categories: 11.040.50 - Radiographic equipment; 17.140.50 - Electroacoustics. The ICS classification helps identify the subject area and facilitates finding related standards.

You can purchase EN 61206:1995 directly from iTeh Standards. The document is available in PDF format and is delivered instantly after payment. Add the standard to your cart and complete the secure checkout process. iTeh Standards is an authorized distributor of CLC standards.

기사 제목: EN 61206:1995 - 초음파 - 연속파 도플러 시스템 - 시험 절차 기사 내용: 이 글은 연속파 초음파 도플러 유량계, 속도계 또는 태아 심박 수 검출기 및 도플러 초음파 시스템의 다양한 성능 특성을 확인하기 위한 독특한 도플러 시험 대상에 대한 측정 방법에 대해 설명합니다. 전기적 안전과 음향 출력은 포함되지 않습니다. 이 출판물은 2형 기술 보고서로 분류됩니다.

記事のタイトル:EN 61206:1995 - 超音波 - 連続波ドプラーシステム - テスト手順 記事の内容:この記事では、連続波超音波ドプラーフローメーター、速度計、または胎児心拍数検出器、およびドプラー超音波システムの様々な性能特性を測定するための特殊なドプラーテストオブジェクトのテスト手法について説明しています。ただし、電気的安全性および音響出力には関与していません。この文書は2型技術レポートとして分類されています。

The article discusses the test procedures specified in the EN 61206:1995 standard for continuous-wave ultrasonic Doppler systems. These systems are used for measuring flow rates, velocity, and detecting fetal hearts. The standard outlines the methods for determining the performance properties of these systems, but does not cover electrical safety or acoustic output. The publication is classified as a type 2 technical report.