EN 61169-26:2013
(Main)Radio-frequency connectors - Part 26: Sectional specification for TNCA series RF coaxial connectors
Radio-frequency connectors - Part 26: Sectional specification for TNCA series RF coaxial connectors
IEC 61169-26:2013 is a sectional specification (SS), it provides information and rules for the preparation of detail specifications (DS) for TNCA series RF coaxial connectors, with characteristic impedance of 50 Ohms, with threaded coupling and operating frequency limit up to 18 GHz, used in wireless, communication, instrument, antenna, test and measurements, radar, and other fields, connecting with RF cables or micro-strips. It also prescribes mating face dimensions for general connectors-grade 2, dimensional details of standard test connectors-grade 0, gauging information and tests selected from IEC 61169-1, applicable to all detail specifications relating to TNCA series connectors.
Hochfrequenz-Steckverbinder - Teil 26: Rahmenspezifikation für koaxiale HF-Steckverbinder der TNCA-Serie
Connecteurs pour fréquences radioélectriques - Partie 26: Spécification intermédiaire pour les connecteurs coaxiaux RF série TNCA
La CEI 61169-26:2013 est une spécification intermédiaire qui fournit des informations et des règles en vue de l'établissement de spécifications particulières de connecteurs coaxiaux RF de série TNCA d'une impédance de 50 Ohms, doté d'un couplage fileté et d'une limite de fréquence de fonctionnement de 18 GHz, utilisés dans les domaines de la communication et des appareils sans fil, des antennes, des essais et des mesures, des radars ainsi que dans d'autres domaines, permettant la connexion avec les câbles RF ou les microrubans. Elle prescrit également les dimensions des faces d'accouplement pour des connecteurs d'usage général classe 2, les détails dimensionnels des connecteurs d'essai normalisés classe 0, les informations concernant les calibres et les essais choisis dans la CEI 61169-1 applicables à toutes les spécifications particulières ayant trait aux connecteurs de la série TNCA.
Radiofrekvenčni konektorji - 26. del: Področna specifikacija za koaksialni radiofrekvenčni (RF) konektor serije TNCA (IEC 61169-26:2013)
General Information
Standards Content (Sample)
SLOVENSKI STANDARD
01-februar-2014
5DGLRIUHNYHQþQLNRQHNWRUMLGHO3RGURþQDVSHFLILNDFLMD]DNRDNVLDOQL
UDGLRIUHNYHQþQL5)NRQHNWRUVHULMH71&$,(&
Radio-frequency connectors - Part 26: Sectional specification of TNCA series RF coaxial
connector
Hochfrequenz-Steckverbinder - Teil 26: Rahmenspezifikation für koaxiale HF-
Steckverbinder der TNCA-Serie
Connecteurs pour fréquences radioélectriques - Partie 26: Spécification intermédiaire
pour les connecteurs coaxiaux RF série TNCA
Ta slovenski standard je istoveten z: EN 61169-26:2013
ICS:
33.120.30 5DGLRIUHNYHQþQLNRQHNWRUML R.F. connectors
5)
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
EUROPEAN STANDARD
EN 61169-26
NORME EUROPÉENNE
April 2013
EUROPÄISCHE NORM
ICS 31.220.10
English version
Radio-frequency connectors -
Part 26: Sectional specification for TNCA series RF coaxial connectors
(IEC 61169-26:2013)
Connecteurs pour fréquences Hochfrequenz-Steckverbinder -
radioélectriques - Teil 26: Rahmenspezifikation für koaxiale
Partie 26: Spécification intermédiaire pour HF-Steckverbinder der TNCA-Serie
les connecteurs coaxiaux RF série TNCA (IEC 61169-26:2013)
(CEI 61169-26:2013)
This European Standard was approved by CENELEC on 2013-03-05. CENELEC members are bound to comply
with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard
the status of a national standard without any alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on
application to the CEN-CENELEC Management Centre or to any CENELEC member.
This European Standard exists in three official versions (English, French, German). A version in any other
language made by translation under the responsibility of a CENELEC member into its own language and notified
to the CEN-CENELEC Management Centre has the same status as the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus,
the Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany,
Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland,
Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom.
CENELEC
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
Management Centre: Avenue Marnix 17, B - 1000 Brussels
© 2013 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.
Ref. No. EN 61169-26:2013 E
Foreword
The text of document 46F/220/FDIS, future edition 1 of IEC 61169-26, prepared by SC 46F, R.F. and
microwave passive components, of IEC TC 46, Cables, wires, waveguides, R.F. connectors, R.F. and
microwave passive components and accessories was submitted to the IEC-CENELEC parallel vote and
approved by CENELEC as EN 61169-26:2013.
The following dates are fixed:
(dop) 2013-12-05
• latest date by which the document has
to be implemented at national level by
publication of an identical national
standard or by endorsement
• latest date by which the national (dow) 2016-03-05
standards conflicting with the
document have to be withdrawn
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. CENELEC [and/or CEN] shall not be held responsible for identifying any or all such patent
rights.
Endorsement notice
The text of the International Standard IEC 61169-26:2013 was approved by CENELEC as a European
Standard without any modification.
- 3 - EN 61169-26:2013
Annex ZA
(normative)
Normative references to international publications
with their corresponding European publications
The following documents, in whole or in part, are normatively referenced in this document and are
indispensable for its application. For dated references, only the edition cited applies. For undated
references, the latest edition of the referenced document (including any amendments) applies.
NOTE When an international publication has been modified by common modifications, indicated by (mod), the relevant EN/HD
applies.
Publication Year Title EN/HD Year
IEC 60068-1 - Environmental testing - EN 60068-1 -
Part 1: General and guidance
IEC 61169-1 1992 Radio-frequency connectors - EN 61169-1 1994
+ A1 1996 Part 1: Generic specification - General + A1 1996
+ A2 1997 requirements and measuring methods + A2 1997
IEC 61169-26 ®
Edition 1.0 2013-01
INTERNATIONAL
STANDARD
NORME
INTERNATIONALE
colour
inside
Radio-frequency connectors –
Part 26: Sectional specification for TNCA series RF coaxial connectors
Connecteurs pour fréquences radioélectriques –
Partie 26: Spécification intermédiaire pour les connecteurs coaxiaux RF série
TNCA
INTERNATIONAL
ELECTROTECHNICAL
COMMISSION
COMMISSION
ELECTROTECHNIQUE
PRICE CODE
INTERNATIONALE
CODE PRIX U
ICS 31.220.10 ISBN 978-2-83220-624-9
– 2 – 61169-26 © IEC:2013
CONTENTS
FOREWORD . 4
1 Scope . 6
2 Normative reference . 6
3 Mating face and gauge information . 6
3.1 Dimensions – General connectors – Grade 1 . 6
3.1.1 Connector with pin-centre contact (see Figure 1) . 6
3.1.2 Connector with socket-centre contact (see Figure 2) . 8
3.2 Gauges . 9
3.2.1 Gauge pins for socket-centre contact (see Figure 3) . 9
3.2.2 Test procedure . 9
3.3 Dimensions – Standard test connectors – Grade 0 . 10
3.3.1 Connector with pin-centre contact (see Figure 4) . 10
3.3.2 Connector with socket-centre contact (see Figure 5) . 11
4 Quality assessment procedure . 12
4.1 General . 12
4.2 Rating and characteristics (see Clause 6 of IEC 61169-1:1992) . 12
4.3 Test schedule and inspection requirements – Acceptance tests . 15
4.3.1 Acceptance tests (see Table 8) . 15
4.3.2 Periodic tests. 16
4.4 Procedures . 18
4.4.1 Quality conformance inspection . 18
4.4.2 Qualification approval and its maintenance . 18
5 Instructions for preparation of detail specifications . 19
5.1 General . 19
5.2 Identification of the component . 19
5.3 Performance . 19
5.4 Marking, ordering information and related matters . 19
5.5 Selection of tests, test conditions and severities . 19
5.6 Blank detail specification pro-forma for type TNCA connector . 21
Bibliography . 26
Figure 1 – Connector with pin-centre contact (for dimensions and key, see Table 1) . 7
Figure 2 – Connector with socket-centre contact (for dimensions and key, see Table 2) . 8
Figure 3 – Gauge pins for socket-centre contact (for dimensions, see Table 3) . 9
Figure 4 – Connector with pin-centre contact (for dimensions and key, see Table 4) . 10
Figure 5 – Connector with socket-centre contact (for dimensions and key, see Table 5) . 11
Table 1 – Dimensions of connector with pin-centre contact . 7
Table 2 – Dimensions of connector with socket-centre contact . 8
Table 3 – Dimensions of gauge pins for socket-centre contact . 9
Table 4 – Dimensions of connector with pin-centre contact . 10
Table 5 – Dimensions of connector with socket-centre contact . 11
Table 6 – Preferred climatic categories (see IEC 60068-1) . 12
Table 7 – Ratings and characteristics . 13
61169-26 © IEC:2013 – 3 –
Table 8 – Acceptance tests . 15
Table 9 – Periodic tests . 16
– 4 – 61169-26 © IEC:2013
INTERNATIONAL ELECTROTECHNICAL COMMISSION
____________
RADIO-FREQUENCY CONNECTORS –
Part 26: Sectional specification for TNCA series
RF coaxial connectors
FOREWORD
1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of IEC is to promote
international co-operation on all questions concerning standardization in the electrical and electronic fields. To
this end and in addition to other activities, IEC publishes International Standards, Technical Specifications,
Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC
Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested
in the subject dealt with may participate in this preparatory work. International, governmental and non-
governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely
with the International Organization for Standardization (ISO) in accordance with conditions determined by
agreement between the two organizations.
2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international
consensus of opinion on the relevant subjects since each technical committee has representation from all
interested IEC National Committees.
3) IEC Publications have the form of recommendations for international use and are accepted by IEC National
Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC
Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any
misinterpretation by any end user.
4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications
transparently to the maximum extent possible in their national and regional publications. Any divergence
between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in
the latter.
5) IEC itself does not provide any attestation of conformity. Independent certification bodies provide conformity
assessment services and, in some areas, access to IEC marks of conformity. IEC is not responsible for any
services carried out by independent certification bodies.
6) All users should ensure that they have the latest edition of this publication.
7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and
members of its technical committees and IEC National Committees for any personal injury, property damage or
other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and
expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC
Publications.
8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is
indispensable for the correct application of this publication.
9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of
patent rights. IEC shall not be held respo
...
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.