Radio-frequency connectors - Part 1: Generic specification - General requirements and measuring methods

EN following parallel vote * IEC/SC 46D projects transferred into IEC/SC 46F

Hochfrequenz-Steckverbinder - Teil 1: Fachgrundspezifikation - Allgemeine Anforderungen und Meßverfahren

Connecteurs pour fréquences radioélectriques - Partie 1: Spécification générique - Prescriptions générales et méthodes de mesure

Radio-frequency connectors - Part 1: Generic specification - General requirements and measuring methods - Amendment A1 (IEC 61169-1:1992/A1:1996)

General Information

Status
Withdrawn
Publication Date
28-Jul-1996
Withdrawal Date
31-Mar-1997
Current Stage
9960 - Withdrawal effective - Withdrawal
Start Date
14-Aug-2016
Completion Date
14-Aug-2016

Relations

Buy Standard

Amendment
EN 61169-1:1998/A1:1998
English language
10 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

SLOVENSKI STANDARD
SIST EN 61169-1:1998/A1:1998
01-april-1998
Radio-frequency connectors - Part 1: Generic specification - General requirements
and measuring methods - Amendment A1 (IEC 61169-1:1992/A1:1996)
Radio-frequency connectors -- Part 1: Generic specification - General requirements and
measuring methods
Hochfrequenz-Steckverbinder -- Teil 1: Fachgrundspezifikation - Allgemeine
Anforderungen und Meßverfahren
Connecteurs pour fréquences radioélectriques -- Partie 1: Spécification générique -
Prescriptions générales et méthodes de mesure
Ta slovenski standard je istoveten z: EN 61169-1:1994/A1:1996
ICS:
33.120.30 5DGLRIUHNYHQþQLNRQHNWRUML R.F. connectors
5)
SIST EN 61169-1:1998/A1:1998 en
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------

SIST EN 61169-1:1998/A1:1998

---------------------- Page: 2 ----------------------

SIST EN 61169-1:1998/A1:1998

---------------------- Page: 3 ----------------------

SIST EN 61169-1:1998/A1:1998

---------------------- Page: 4 ----------------------

SIST EN 61169-1:1998/A1:1998
NORME CEI
INTERNATIONALE IEC
1169-1
INTERNATIONAL
QC 220000
STANDARD
1992
Amendement 1
Amendment 1
1996-05
Amendement 1
Connecteurs pour fréquences radioélectriques
Partie 1:
Spécification générique — Prescriptions générales
et méthodes de mesure
Amendment 1
Radio-
frequency connectors
Part 1:
Generic specification — General requirements
and measuring methods
© CEI 1996 Droits de reproduction réservés — Copyright — all rights reserved
Bureau Central de la Commission Electrotechnique Internationale 3, rue de Varembé Genève, Suisse
E PRIX
Commission Electrotechnique Internationale COD
International Electrotechnical Commission PRICE CODE
IEC MemayHapoaHaR 3neerporexHu4eceaR HoMHCCHR
Pour prix, voir catalogue en vigueur

For price, see current catalogue

---------------------- Page: 5 ----------------------

SIST EN 61169-1:1998/A1:1998
1169-1 Amend. 1 ©IEC:1996 - 3 -
FOREWORD
This amendment has been prepared by sub-committee 46D: RF connectors, of IEC
technical committee 46: Cables, wires, waveguides, r.f. connectors, and accessories for
communication and signalling.
The text of this amendment is based on the following documents:
DIS
Repo rt on voting
46D/245/FDIS 46D/276/RVD
Full information on the voting for the approval of this amendment can be found in the
report on voting indicated in the above table.
Page 3
CONTENTS
Add, on page 5, the title of annex C as follows:
C Guidelines for the determination of tensile forces and torsional moments to be
applied when testing the effectiveness of cable retention with recommended values
for some typical cables
Page 75
9.2.3.4 Information to be given in the relevant specification
Add the following new item d):
d) When performing continuity measurements on mated cabled connectors, pre-
cautions should be taken to avoid erroneous results due to the thermal coefficient
of resistance of the cable.
Page 121
Add the following new subclause:
9.3.15 Safety wire hole pull-out
A single strand of safety wire shall be looped through the safety hole and secured to itself.
A specified force shall be applied in two directions to the safety wire pulling away from
the connector. One pull shall be parallel to the connector axis and one pull shall be per-
pendicular to the connector axis (see figure 24). This test is to be conducted under static
conditions. All holes are to be tested individually.

---------------------- Page: 6 ----------------------

SIST EN 61169-1:1998/A1:1998
1169-1 Amend. 1 ©IEC:1996 - 5 -
The safety wire shall be made of corrosion-resistant steel 0,50 mm in diameter or 0,35 mm
in diameter.
The preferred value for this test shall be:
- applied force: 67 N minimum;
- duration: 30 s.
Force
<)01
IEC 39I/y(
Figure 24 - Safety wire hole pull-out procedure
Last test in Group Di
Assessment level M
Assessment level H
Test
method Test Test IL AQL
IL AQL Period Period
QC 220000 required
% required %
Subclause
9.3.15 ia S4 0,4
Lot ia S3 4 Lot
Effectiveness of safety wire locking holes; piece pa rt
s (D)
Page 163
Add, after annex B, the new annex C as follows:
Annex C
(informative)
Guidelines for the determination of tensile forces and
torsional moments to be applied when testing the effectiveness
of cable retention with recommended values
for some typical cables
C.1 General
The details given below, including the recommended values for tensile forces and
torsional moments for typical cables in clause C.3, are applicable to both clamp and crimp
methods of cable retention.

---------------------- Page: 7 ----------------------

SIST EN 61169-1:1998/A1:1998
1169-1 Amend. 1 ©IEC:1996 - 7 -
C.2 Cable construction and calculation of outer conductor cross
-sectional area
C.2.1 Semi-rigid cable
A = 1/4 n (Da2 -
D2)
/EC 400
Examples:
Diameter
A
Cross-sectional
mm
Da mm2
d
1,194
0,940 0,426
2,197 1,676 1,584
...