Optical fibre amplifiers - Basic specification - Part 6-1: Test methods for pump leakage parameters - Optical demultiplexer

Applies to optical fibre amplifiers using active fibres, containing rare-earth dopants, presently commercially available. Establishes uniform requirements for accurate and reliable measurements, by means of the optical demultiplexer test method, of the following OFA parameters: - pump leakage to output; - pump leakage to input.

Lichtwellenleiter-Verstärker - Grundspezifikation - Teil 6-1: Prüfverfahren für Pumpverlustparameter - Optischer Demultiplexer

Amplificateurs à fibres optiques - Spécification de base - Partie 6-1: Méthodes d'essai pour les paramètres de fuite de pompe - Démultiplexeur optique

S'applique aux amplificateurs à fibres optiques (AFO) utilisant des fibres actives contenant des dopants de terre rare, actuellement commercialisés. Etablit des spécifications uniformes pour des mesures précises et fiables, par le biais de la méthode d'essai du démultiplexeur optique, des paramètres d'AFO donnés ci-dessous: - fuite de pompe en sortie; - fuite de pompe en entrée.

Optical fibre amplifiers - Basic specification - Part 6-1: Test methods for pump leakage parameters - Optical demultiplexer (IEC 61290-6-1:1998)

General Information

Status
Published
Publication Date
10-Aug-1998
Withdrawal Date
30-Apr-2001
Current Stage
6060 - Document made available - Publishing
Start Date
11-Aug-1998
Completion Date
11-Aug-1998

Buy Standard

Standard
EN 61290-6-1:1999
English language
14 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)


SLOVENSKI STANDARD
01-maj-1999
Optical fibre amplifiers - Basic specification - Part 6-1: Test methods for pump
leakage parameters - Optical demultiplexer (IEC 61290-6-1:1998)
Optical fibre amplifiers - Basic specification -- Part 6-1: Test methods for pump leakage
parameters - Optical demultiplexer
Lichtwellenleiter-Verstärker - Grundspezifikation -- Teil 6-1: Prüfverfahren für
Pumpverlustparameter - Optischer Demultiplexer
Amplificateurs à fibres optiques - Spécification de base -- Partie 6-1: Méthodes d'essai
pour les paramètres de fuite de pompe - Démultiplexeur optique
Ta slovenski standard je istoveten z: EN 61290-6-1:1998
ICS:
33.180.30 2SWLþQLRMDþHYDOQLNL Optic amplifiers
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

NORME
CEI
INTERNATIONALE
IEC
61290-6-1
INTERNATIONAL
Première édition
STANDARD
First edition
1998-06
Amplificateurs à fibres optiques –
Spécification de base –
Partie 6-1:
Méthodes d’essai pour les paramètres
de fuite de pompe –
Démultiplexeur optique
Optical fibre amplifiers –
Basic specification –
Part 6-1:
Test methods for pump leakage parameters –
Optical demultiplexer
 IEC 1998 Droits de reproduction réservés  Copyright - all rights reserved
Aucune partie de cette publication ne peut être reproduite ni No part of this publication may be reproduced or utilized in
utilisée sous quelque forme que ce soit et par aucun any form or by any means, electronic or mechanical,
procédé, électronique ou mécanique, y compris la photo- including photocopying and microfilm, without permission in
copie et les microfilms, sans l'accord écrit de l'éditeur. writing from the publisher.
International Electrotechnical Commission 3, rue de Varembé Geneva, Switzerland
Telefax: +41 22 919 0300 e-mail: inmail@iec.ch IEC web site http: //www.iec.ch
CODE PRIX
Commission Electrotechnique Internationale
PRICE CODE L
International Electrotechnical Commission
Pour prix, voir catalogue en vigueur
For price, see current catalogue

61290-6-1 © IEC:1998 – 3 –
CONTENTS
Page
FOREWORD . 5
INTRODUCTION . 7
Clause
1 Scope and object . 9
2 Normative reference . 9
3 Apparatus. 9
4 Test sample. 13
5 Procedure . 13
6 Calculation . 17
7 Test results . 17
Figure 1 – Typical arrangement of the optical demultiplexer test apparatus for pump
leakage measurements. 11
Figure 2 – Set-up for insertion loss measurement of the optical demultiplexer . 15
Annex A (informative) List of abbreviations . 19
Annex B (informative) Bibliography . 21

61290-6-1 © IEC:1998 – 5 –
INTERNATIONAL ELECTROTECHNICAL COMMISSION
___________
OPTICAL FIBRE AMPLIFIERS –
BASIC SPECIFICATION –
Part 6-1: Test methods for pump leakage parameters –
Optical demultiplexer
FOREWORD
1) The IEC (International Electrotechnical Commission) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of the IEC is to promote
international co-operation on all questions concerning standardization in the electrical and electronic fields. To
this end and in addition to other activities, the IEC publishes International Standards. Their preparation is
entrusted to technical committees; any IEC National Committee interested in the subject dealt with may
participate in this preparatory work. International, governmental and non-governmental organizations liaising
with the IEC also participate in this preparation. The IEC collaborates closely with the International Organization
for Standardization (ISO) in accordance with conditions determined by agreement between the two
organizations.
2) The formal decisions or agreements of the IEC on technical matters express, as nearly as possible, an
international consensus of opinion on the relevant subjects since each technical committee has representation
from all interested National Committees.
3) The documents produced have the form of recommendations for international use and are published in the form
of standards, technical reports or guides and they are accepted by the National Committees in that sense.
4) In order to promote international unification, IEC National Committees undertake to apply IEC International
Standards transparently to the maximum extent possible in their national and regional standards. Any
divergence between the IEC Standard and the corresponding national or regional standard shall be clearly
indicated in the latter.
5) The IEC provides no marking procedure to indicate its approval and cannot be rendered responsible for any
equipment declared to be in conformity with one of its standards.
6) Attention is drawn to the possibility that some of the elements of this International Standard may be the subject
of patent rights. The IEC shall not be held responsible for identifying any or all such patent rights.
International Standard IEC 61290-6-1 has been prepared by subcommittee 86C: Fibre optic
systems and active devices, of IEC technical committee 86: Fibre optics.
It shall be read in conjunction with IEC 61291-1.
The text of this standard is based on the following documents:
FDIS Report on voting
86C/180/FDIS 86C/204/RVD
Full information on the voting for the approval of this standard can be found in the report on
voting indicated in the above table.
Annexes A and B are for information only.

61290-6-1 © IEC:1998 – 7 –
INTRODUCTION
As far as can be determined, this is the first International Standard on optical fibre amplifiers.
The technology of optical fibre amplifiers is quite new and still emerging, hence amendments
and new editions to this standard can be expected.
Each abbreviation introduced is explained in the text at least the first time it appears. However,
for an easier understanding of the whole text, a list of all abbreviations used is given in
annex A.
61290-6-1 © IEC:1998 – 9 –
OPTICAL FIBRE AMPLIFIERS –
BASIC SPECIFICATION –
Part 6-1: Test methods for pump leakage parameters –
Optical demultiplexer
1 Scope and object
This part of IEC 61290 applies to optical fibre amplifiers (OFAs) using active fibres, containing
rare-earth dopants, presently commercially available.
The object of this standard is to establish uniform requirements for accurate and reliable
measurements, by means of the optical demultiplexer test method, of the following OFA
parameters, as defined in clause 3 of IEC 61291-1:
a) pump leakage to output;
b) pump leakage to input.
NOTE – All numerical values followed by (‡) are currently under consideration.
2 Normative reference
The following normative document contains provisions which, through reference in this text,
constitute provisions of this part of IEC 61290. At the time of publication, the edition indicated
was valid. All normative documents are subject to revision, and parties to agreements based
on this part of IEC 61290 are encouraged to investigate the possibility of applying the most
recent edition of the normative document indicated below. Members of IEC and ISO maintain
registers of currently valid International Standards.
1)
IEC 61291-1,  Optical fibre amplifiers – Part 1: Generic specification
3 Apparatus
A scheme of the measurement set-up is given in figure 1.
___________
1)
To be published.
61290-6-1 © IEC:1998 – 11 –
Optical
demultiplexer
AC
Optical
dB
OFA
source
B
Variable
optical
OFA
Optical
attenuator
under test
isolator
Optical
power
meter
IEC  710/98
Figure 1a – Set-up pump leakage measurements at OFA output
Optical
demultiplexer
A
C
Optical
dB
OFA
source
B
Variable
optical OFA
Optical
attenuator
isolator under test
Optical
power
meter
IEC  711/98
Figure 1b – Se
...