Electromagnetic compatibility (EMC) - Part 4-41: Testing and measurement techniques - Broadband radiated immunity tests

Elektromagnetische Verträglichkeit (EMV) - Teil 4-41: Prüf- und Messverfahren - Prüfungen der breitbandigen Störfestigkeit

Compatibilité électromagnétique (CEM) - Partie 4-41: Techniques d'essai et de mesure - Essais d'immunité aux rayonnements à large bande

Elektromagnetna združljivost (EMC) - 4-41. del: Preskusne in merilne tehnike - Preskusi odpornosti proti širokopasovnemu sevanju

General Information

Status
Not Published
Publication Date
01-Sep-2025
Current Stage
4060 - Enquiry results established and sent to TC, SR, BTTF - Enquiry
Start Date
03-May-2024
Completion Date
03-May-2024

Buy Standard

Draft
prEN IEC 61000-4-41:2024 - BARVE
English language
47 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

SLOVENSKI STANDARD
oSIST prEN IEC 61000-4-41:2024
01-april-2024
Elektromagnetna združljivost (EMC) - 4-41. del: Preskusne in merilne tehnike -
Preskusi odpornosti proti širokopasovnemu sevanju
Electromagnetic compatibility (EMC) - Part 4-41: Testing and measurement techniques -
Broadband radiated immunity tests
Ta slovenski standard je istoveten z: prEN IEC 61000-4-41:2024
ICS:
33.100.20 Imunost Immunity
oSIST prEN IEC 61000-4-41:2024 en
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------
oSIST prEN IEC 61000-4-41:2024

---------------------- Page: 2 ----------------------
oSIST prEN IEC 61000-4-41:2024
77B/884/CDV
COMMITTEE DRAFT FOR VOTE (CDV)

PROJECT NUMBER:
IEC 61000-4-41 ED1
DATE OF CIRCULATION: CLOSING DATE FOR VOTING:
2024-02-09 2024-05-03
SUPERSEDES DOCUMENTS:
77B/870/CD, 77B/881/CC

IEC SC 77B : HIGH FREQUENCY PHENOMENA
SECRETARIAT: SECRETARY:
France Mr Franck GRUFFAZ
OF INTEREST TO THE FOLLOWING COMMITTEES: PROPOSED HORIZONTAL STANDARD:

CIS/A,CIS/F,CIS/H,CIS/I
Other TC/SCs are requested to indicate their interest, if
any, in this CDV to the secretary.
FUNCTIONS CONCERNED:
EMC ENVIRONMENT QUALITY ASSURANCE SAFETY
SUBMITTED FOR CENELEC PARALLEL VOTING NOT SUBMITTED FOR CENELEC PARALLEL VOTING
Attention IEC-CENELEC parallel voting
The attention of IEC National Committees, members of
CENELEC, is drawn to the fact that this Committee Draft
for Vote (CDV) is submitted for parallel voting.
The CENELEC members are invited to vote through the
CENELEC online voting system.

This document is still under study and subject to change. It should not be used for reference purposes.
Recipients of this document are invited to submit, with their comments, notification of any relevant patent rights of
which they are aware and to provide supporting documentation.
Recipients of this document are invited to submit, with their comments, notification of any relevant “In Some
Countries” clauses to be included should this proposal proceed. Recipients are reminded that the CDV stage is
the final stage for submitting ISC clauses. (SEE AC/22/2007 OR NEW GUIDANCE DOC).

TITLE:
Electromagnetic compatibility (EMC) - Part 4-41: Testing and measurement techniques -
Broadband radiated immunity tests

PROPOSED STABILITY DATE: 2026

NOTE FROM TC/SC OFFICERS:


Copyright © 2023 International Electrotechnical Commission, IEC. All rights reserved. It is permitted to
download this electronic file, to make a copy and to print out the content for the sole purpose of preparing National
Committee positions. You may not copy or "mirror" the file or printed version of the document, or any part of it, for
any other purpose without permission in writing from IEC.

---------------------- Page: 3 ----------------------
oSIST prEN IEC 61000-4-41:2024

IEC CDV 61000-4-41/Ed1 © IEC:2024 – 2 – 77B/884/CDV
1 CONTENTS
2
3 FOREWORD . 4
4 INTRODUCTION . 6
5 1 Scope . 7
6 2 Normative references . 7
7 3 Terms and definitions . 7
8 4 General . 8
9 5 Test levels and test signal . 9
10 5.1 Test levels . 9
11 5.2 Test signal . 10
12 5.3 Frequency range and test signal bandwidth . 13
13 5.4 Spectrum mask . 13
14 5.5 Frequency stepping . 15
15 5.6 Selection of level . 15
16 6 Test equipment and level adjustment procedure . 16
17 6.1 Test instrumentation . 16
18 6.2 Description of the test facility
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.