IEC 61000-4-11:2020 is available as IEC 61000-4-11:2020 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 61000-4-11:2020 defines the immunity test methods and range of preferred test levels for electrical and electronic equipment connected to low-voltage power supply networks for voltage dips, short interruptions, and voltage variations. This document applies to electrical and electronic equipment having a rated input current not exceeding 16 A per phase, for connection to 50 Hz or 60 Hz AC networks. It does not apply to electrical and electronic equipment for connection to 400 Hz AC networks. Tests for these networks will be covered by future IEC documents. The object of this document is to establish a common reference for evaluating the immunity of electrical and electronic equipment when subjected to voltage dips, short interruptions and voltage variations. NOTE 1 Voltage fluctuation immunity tests are covered by IEC 61000-4-14. The test method documented in this document describes a consistent method to assess the immunity of equipment or a system against a defined phenomenon. NOTE 2 As described in IEC Guide 107, this is a basic EMC publication for use by product committees of the IEC. As also stated in Guide 107, the IEC product committees are responsible for determining whether this immunity test standard should be applied or not, and, if applied, they are responsible for defining the appropriate test levels. Technical committee 77 and its sub-committees are prepared to co-operate with product committees in the evaluation of the value of particular immunity tests for their products. This third edition cancels and replaces the second edition published in 2004 and Amendment 1:2017. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: - rise time and fall time of transients are now defined terms in Clause 3; - the origin of voltage dips and short interruptions is now stated in Clause 4. Keywords: immunity test methods, low-voltage power supply networks

  • Standard
    33 pages
    English language
    sale 10% off
    e-Library read for
    1 day

2020-12-01: common modification - no xml
2019-10-29: D164/C050: Amendment to add Annex ZZ to EN 55011:2016 & enable citation in OJEU

  • Amendment
    4 pages
    English language
    sale 10% off
    e-Library read for
    1 day

2020-12-01: no xml because common mod
2019-10-29: D164/C050: Amendment to add Annex ZZ to EN 55032:2015 & enable citation in OJEU

  • Amendment
    3 pages
    English language
    sale 10% off
    e-Library read for
    1 day

2020-12-01: common mod - no xml
2019-10-29: D164/C050: Amendment to add Annex ZZ to EN 55014-1:2017 & enable citation in OJEU

  • Amendment
    4 pages
    English language
    sale 10% off
    e-Library read for
    1 day

2020-12-01: common mod - no xml
2019-10-29: D164/C050: Amendment to add Annex ZZ to EN IEC 55015:2019 & enable citation in OJEU

  • Amendment
    3 pages
    English language
    sale 10% off
    e-Library read for
    1 day

NEW!IEC 61000-3-11:2017 is available as IEC 61000-3-11:2017 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 61000-3-11:2017 is concerned with the emission of voltage changes, voltage fluctuations and flicker produced by equipment and impressed on the public low-voltage supply system. It specifies the limits of voltage changes produced by equipment tested under specified conditions. This edition includes the following significant technical changes with respect to the previous edition: a) addition of a new Annex A which explains the limitations and effectiveness of IEC 61000‑3-11 regarding the connection of multiple items of similar equipment at the same location in the supply network.

  • Standard
    22 pages
    English language
    sale 10% off
    e-Library read for
    1 day

NEW!IEC 61000-6-4:2018 is available as IEC 61000-6-4:2018 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.

  • Standard
    31 pages
    English language
    sale 10% off
    e-Library read for
    1 day

2020-03-12: A11 allows citation EMCD
2019-09-19: mtg TC 210, CCMC & EC: 80/80 rule: Temporary solution = to have a Note in Annex ZZ. - longer term: 80/80 rule to be removed by end of Sept. 2020
2019-08-13: Annex ZZ in line with EC suggestions received
2019-07-02 BT D162/C064: to be published as non hEN - harmonisation to be covered by A11’
2018-07-17 - GEM - unflagged as candidate for citation, not to be offered until issues are solved
2018-05-28  -  TAN - in-check : negative assessment at CDV stage. FDIS stage assessment is not requested.

  • Standard
    78 pages
    English language
    sale 10% off
    e-Library read for
    1 day

2020-12-14 EC letter: citation of EN + A1 put on hold EMC and RED - either to cite with a restriction or TC to povide other solution, link to directives temporary removed
2020-02-19: EC mail with concerns for citation under RED and subsequently also EMC - CCMC proposal to discuss during EC EG RE 2020-03-02
2020-02-07: EC letter acception for citation EMCD
2019-06-06 D163/C005: noting positive assessment, approved Annex ZZ and ZA and asked to make document available
2019-04-24: BT doc prepared
2019-03-32 D162/C065 TC to submit EMC elements to BT
2019-02-01: confirmation of positive assessment for RED and EMCD
2019-01-23 lacking answer, EY Confirmation requested
2019-01-07 EY Confirmation requested
2018-11-30 Discussed with under EY Quality Review: simplifierd AR is inconclusive
2018-09-03: HAS assessment (2018-08-02) : interpreted to be 'Compliant', go to BT for integration in the text of Annexes ZZ
2018-05-22: submitted for assessment on 2018-05-18

  • Amendment
    8 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of CISPR 16 specifies the characteristics and performance of equipment for the
measurement of radio disturbance in the frequency range 9 kHz to 18 GHz. In addition,
requirements are provided for specialized equipment for discontinuous disturbance
measurements.
NOTE In accordance with IEC Guide 107, CISPR 16-1-1 is a basic electromagnetic compatibility (EMC) standard
for use by product committees of the IEC. As stated in Guide 107, product committees are responsible for
determining the applicability of a basic EMC standard. CISPR and its subcommittee are prepared to co-operate
with product committees in the evaluation of the value of particular EMC tests for specific products.
The specifications in this document apply to electromagnetic interference (EMI) receivers and
spectrum analyzers. The term “measuring receiver” used in this document refers to both EMI
receivers and spectrum analyzers (see also 3.7). The calibration requirements for measuring
receivers are detailed in Annex J.
Further guidance on the use of spectrum analyzers can be found in Annex B of any one of the
following documents: CISPR 16-2-1:2014, CISPR 16-2-2:2010, or CISPR 16-2-3: 2016.

  • Standard
    98 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of IEC 61000 focuses on the immunity requirements and test methods for electrical and electronic equipment, under operational conditions, with regard to: a) repetitive slow damped oscillatory waves occurring mainly in power, control and signal cables installed in high voltage and medium voltage (HV/MV) substations; b) repetitive fast damped oscillatory waves occurring mainly in power, control and signal cables installed in gas insulated substations (GIS) and in some cases also air insulated substations (AIS) or in any installation due to high-altitude electromagnetic pulse (HEMP) phenomena. The object of this document is to establish a common and reproducible reference for evaluating the immunity of electrical and electronic equipment when subjected to damped oscillatory waves on supply, signal, control and earth ports. The test method documented in this part of IEC 61000 describes a consistent method to assess the immunity of an equipment or system against a defined phenomenon. NOTE As described in IEC Guide 107, this is a basic EMC publication for use by product committees of the IEC. As also stated in Guide 107, the IEC product committees are responsible for determining whether this immunity test standard is applied or not, and if applied, they are responsible for determining the appropriate test levels and performance criteria. 1 The document defines: – test voltage and current waveforms; – ranges of test levels; – test equipment; – calibration and verification procedures of test equipment; – test setups; – test procedure.

  • Standard
    60 pages
    English language
    sale 10% off
    e-Library read for
    1 day

2019-03-19: TC Secretary has requested to proceed with publication. No Annex ZZ needed.
Link to  M/452 (safety of music players) removed, standard supporting to EMC, but not as hEN.

  • Amendment
    7 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of CISPR 16 specifies the characteristics and performance of equipment for the
measurement of radiated disturbances in the frequency range 9 kHz to 18 GHz. Specifications
for antennas and test sites are included.
NOTE In accordance with IEC Guide 107, CISPR 16-1-4 is a basic EMC publication for use by product committees
of the IEC. As stated in Guide 107, product committees are responsible for determining the applicability of the EMC
standard. CISPR and its sub-committees are prepared to cooperate with product committees in the evaluation of
the value of particular EMC tests for specific products.
The requirements of this publication apply at all frequencies and for all levels of radiated
disturbances within the CISPR indicating range of the measuring equipment.
Methods of measurement are covered in Part 2-3, further information on radio disturbance is
given in Part 3, and uncertainties, statistics and limit modelling are covered in Part 4 of
CISPR 16.

  • Standard
    110 pages
    English language
    sale 10% off
    e-Library read for
    1 day

NEW!IEC 61000-3-2:2018 is available as IEC 61000-3-2:2018 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 61000-3-2:2018 deals with the limitation of harmonic currents injected into the public supply system. It specifies limits of harmonic components of the input current which can be produced by equipment tested under specified conditions. It is applicable to electrical and electronic equipment having a rated input current up to and including 16 A per phase, and intended to be connected to public low‑voltage distribution systems. Arc welding equipment which is not professional equipment, with a rated input current up to and including 16 A per phase, is included in this document. Arc welding equipment intended for professional use, as specified in IEC 60974-1, is excluded from this document and can be subject to installation restrictions as indicated in IEC 61000-3-12. The tests according to this document are type tests. For systems with nominal voltages less than but not equal to 220 V (line-to-neutral), the limits have not yet been considered. This fifth edition cancels and replaces the fourth edition published in 2014. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) an update of the emission limits for lighting equipment with a rated power ≤ 25 W to take into account new types of lighting equipment; b) the addition of a threshold of 5 W under which no emission limits apply to all lighting equipment; c) the modification of the requirements applying to the dimmers when operating non‑incandescent lamps; d) the addition of test conditions for digital load side transmission control devices; e) the removal of the use of reference lamps and reference ballasts for the tests of lighting equipment; f) the simplification and clarification of the terminology used for lighting equipment; g) the classification of professional luminaires for stage lighting and studios under Class A; h) a clarification about the classification of emergency lighting equipment; i) a clarification for lighting equipment including one control module with an active input power ≤ 2 W; j) an update of the test conditions for television receivers; k) an update of the test conditions for induction hobs, taking also into account the other types of cooking appliances; l) for consistency with IEC 61000-3-12, a change of the scope of IEC 61000-3-2 from equipment with an input current ≤ 16 A to equipment with a rated input current ≤ 16 A. Keywords: harmonic currents

  • Standard
    38 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Standard – translation
    39 pages
    Slovenian language
    sale 10% off
    e-Library read for
    1 day

applies to electrical and electronic apparatus intended for use in industrial environments, as described below. Immunity requirements in the frequency range 0 Hz to 400 GHz are covered. No tests need to be performed at frequencies where no requirements are specified. This generic EMC immunity standard is applicable if no relevant dedicated product or product-family EMC immunity standard exists. This standard applies to apparatus intended to be connected to a power network supplied from a high or medium voltage transformer dedicated to the supply of an installation feeding manufacturing or similar plant, and intended to operate in or in proximity to industrial locations, as described below. This standard applies also to apparatus which is battery operated and intended to be used in industrial locations. The environments encompassed by this standard are industrial, both indoor and outdoor. The immunity requirements have been selected to ensure an adequate level of immunity for apparatus at industrial locations. The levels do not, however, cover extreme cases, which may occur at any location, but with an extremely low probability of occurrence. Not all disturbance phenomena have been included for testing purposes in this standard, but only those considered as relevant for the equipment covered by this standard. These test requirements represent essential electromagnetic compatibility immunity requirements.

  • Standard
    22 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Applies to electrical and electronic apparatus intended for use in residential, commercial and light-industrial environments. Immunity requirements in the frequency range 0 Hz to 400 GHz are covered. No tests need to be performed at frequencies where no requirements are specified. This generic EMC immunity standard is applicable if no relevant dedicated product or product-family EMC immunity standard exists. This standard applies to apparatus intended to be directly connected to a low-voltage public mains network or connected to a dedicated DC source which is intended to interface between the apparatus and the low-voltage public mains network. This standard applies also to apparatus which is battery operated or is powered by a non-public, but non-industrial, low-voltage power distribution system if this apparatus is intended to be used in the locations described below. The environments encompassed by this standard are residential, commercial and light-industrial locations, both indoor and outdoor. The following list, although not comprehensive, gives an indication of locations which are included: - residential properties, for example houses, apartments; - retail outlets, for example shops, supermarkets; - business premises, for example offices, banks; - areas of public entertainment, for example cinemas, public bars, dance halls; - outdoor locations, for example petrol stations, car parks, amusement and sports centres; - light-industrial locations, for example workshops, laboratories, service centres. Locations which are characterised by being supplied directly at low voltage from the public mains network are considered to be residential, commercial or light-industrial. The immunity requirements have been selected to ensure an adequate level of immunity for apparatus at residential, commercial and light-industrial locations. The levels do not, however, cover extreme cases, which may occur at any location, but with an extremely low probability of occurrenc

  • Standard
    22 pages
    English language
    sale 10% off
    e-Library read for
    1 day

NEW!IEC 61000-4-12:2017 is available as IEC 61000-4-12:2017 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 61000-4-12:2017 relates to the immunity requirements and test methods for electrical and electronic equipment, under operational conditions, to ring waves occurring in low-voltage power, control and signal lines supplied by public and non-public networks. The object of this document is to establish a common reference for evaluating the immunity of electrical and electronic equipment when subjected to ring waves. The test method documented in this part of IEC 61000 describes a consistent method to assess the immunity of an equipment or system against a defined phenomenon. It has the status of a basic EMC publication in accordance with IEC Guide 107. This edition includes the following significant technical changes with respect to the previous edition: a) addition of a mathematical modelling of ring wave waveform; b) new Annex B on selection of generators and test levels; c) new Annex C on explanatory notes; d) new Annex D on measurement uncertainty; e) addition of high speed CDN; f) addition of a calibration procedure for CDN.

  • Standard
    49 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This standard is concerned with conducted disturbances in the frequency range from 0 kHz to 9 kHz, with an extension up to 148,5 kHz specifically for mains signalling systems. It gives compatibility levels for public low voltage a.c. distribution systems having a nominal voltage up to 420 V, single-phase or 690 V, three-phase and a nominal frequency of 50 Hz or 60 Hz.

  • Amendment
    17 pages
    English language
    sale 10% off
    e-Library read for
    1 day

CISPR 35:2016 applies to multimedia equipment (MME) having a rated AC or DC supply voltage not exceeding 600 V. The objectives of this document are:<br /> - to establish requirements which provide an adequate level of intrinsic immunity so that the MME will operate as intended in its environment in the frequency range 0 kHz to 400 GHz; and<br /> - to specify procedures to ensure the reproducibility of tests and the repeatability of results.

  • Standard
    90 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 61000-4-39:2017 specifies immunity requirements for electrical and electronic equipment when it is exposed to radiated electromagnetic energy from RF transmitters used in close proximity. It establishes test levels and the required test procedures. The applicable frequency range is 9 kHz to 6 GHz. It has the status of a basic EMC publication in accordance with IEC Guide 107.

  • Standard
    43 pages
    English language
    sale 10% off
    e-Library read for
    1 day

CISPR 16-2-3:2016 is available as <a href="https://webstore.iec.ch/publication/25875">CISPR 16-2-3:2016 RLV</a> which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.<br /> <br /> CISPR 16-2-3:2016 specifies the methods of measurement of radiated disturbance phenomena in the frequency range of 9 kHz to 18 GHz. The aspects of measurement uncertainty are specified in CISPR 16-4-1 and CISPR 16-4-2. It has the status of a basic EMC publication in accordance with IEC Guide 107, "Electromagnetic compatibility - Guide to the drafting of electromagnetic compatibility publications". This fourth edition edition cancels and replaces the third edition published in 2010, its Amendment 1:2010 and its Amendment 2:2014. This edition constitutes a technical revision.

  • Standard
    106 pages
    English language
    sale 10% off
    e-Library read for
    1 day

CISPR 14-1:2016 specifies the requirements that apply to the emission of radio-frequency disturbances in the frequency range 9 kHz to 400 GHz from appliances, electric tools and similar apparatus, whether powered by AC or DC (including a battery). Also included in the scope of this standard are separate parts of the above mentioned equipment such as motors and switching devices (e.g. power or protective relays); however, no emission requirements apply to such separate parts, unless otherwise stated in this standard. This sixth edition cancels and replaces the fifth edition published in 2005, Amendment 1:2008 and Amendment 2:2011. This edition constitutes a technical revision. The contents of the corrigendum of October 2016 and interpretation sheet 1 and 2 of May 2017 have been included in this copy.

  • Standard
    99 pages
    English language
    sale 10% off
    e-Library read for
    1 day

2020-03-12: A11 allows citation EMCD
2019-08-13: Annex ZZ in line with EC suggestions received
2018-12-05: TC to clarify if improved FW is needed
2017-04-19: D156/C084 - Ratified standards not being made available
2017-03-28: BT decided to have this standard published (D156/C084)
2016-10: Publication on the hold pending Annex ZZ and positive assessment about EMC directive

  • Amendment
    14 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 61000-4-31:2016 relates to the conducted immunity of electrical and electronic equipment to electromagnetic disturbances coming from intended and/or unintended broadband signal sources in the frequency range 150 kHz up to 80 MHz. It has the status of a basic EMC publication in accordance with IEC Guide 107.

  • Standard
    46 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 61000-4-10:2016 is available as IEC 61000-4-10:2016 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition. IEC 61000-4-10:2016 specifies the immunity requirements, test methods, and range of recommended test levels for equipment subjected to damped oscillatory magnetic disturbances related to medium voltage and high voltage sub-stations. This second edition cancels and replaces the first edition published in 1993 and Amendment 1:2000. This edition constitutes a technical revision.

  • Standard
    44 pages
    English language
    sale 10% off
    e-Library read for
    1 day

ISPR 25:2016 contains limits and procedures for the measurement of radio disturbances in the frequency range of 150 kHz to 2 500 MHz. The standard applies to any electronic/electrical component intended for use in vehicles, trailers and devices. Refer to International Telecommunications Union (ITU) publications for details of frequency allocations. The limits are intended to provide protection for receivers installed in a vehicle from disturbances produced by components/modules in the same vehicle. The method and limits for a complete vehicle (whether connected to the power mains for charging purposes or not) are in Clause 5 and the methods and limits for components/modules are in Clause 6. Only a complete vehicle test can be used to determine the component compatibility with respect to a vehicle's limit. The receiver types to be protected are, for example, broadcast receivers (sound and television), land mobile radio, radio telephone, amateur, citizens' radio, Satellite Navigation (GPS etc.), Wi-Fi and Bluetooth. For the purpose of this standard, a vehicle is a machine, which is self-propelled by an internal combustion engine, electric means, or both. Vehicles include (but are not limited to) passenger cars, trucks, agricultural tractors and snowmobiles. Annex A provides guidance in determining whether this standard is applicable to particular equipment. This fourth edition cancels and replaces the third edition published in 2008. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:<br /> - inclusion of charging mode for electric vehicles (EV) and plug-in electric vehicles (PHEV),<br /> - the methods for chamber validation have been included,<br /> - test methods for shielded power supply systems for high voltages for electric and hybrid electric vehicles have been included,<br /> - overall improvement.<br /> The contents of the corrigendum of October 2017 have been included in this copy

  • Standard
    155 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 61000-4-9:2016 is available as IEC 61000-4-9:2016 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition. IEC 61000-4-9:2016 specifies the immunity requirements, test methods, and range of recommended test levels for equipment subjected to impulse magnetic disturbances mainly encountered in industrial installations, power plants, railway installations, and medium voltage and high voltage sub-stations. This second edition cancels and replaces the first edition published in 1993 and Amendment 1:2000. This edition constitutes a technical revision.

  • Standard
    56 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 61000-1-2:2016 establishes a methodology for the achievement of functional safety only with regard to electromagnetic phenomena. This methodology includes the implication it has on equipment used in such systems and installations. It has the status of a basic safety publication in accordance with IEC Guide 104. This first edition cancels and replaces the second edition of IEC TS 61000-1-2 published in 2008. This edition constitutes a technical revision.

  • Standard
    76 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of CISPR 16 is designated a basic standard, which specifies the characteristics and calibration of the absorbing clamp for the measurement of radio disturbance power in the frequency range 30 MHz to 1 GHz. This second edition cancels and replaces the first edition published in 2003. It constitutes a technical revision. In this edition a more detailed calibration method for the absorbing clamp is specified. Furthermore, new alternative calibration methods are introduced which are more practicable than the one which was specified previously. Additional parameters to describe the absorbing clamp are defined, like the decoupling factor for the broadband absorber (DF) and the decoupling factor for the current transformer (DR), along with their validation methods. A procedure for the validation of the absorbing clamp test site (ACTS) is also included in the document.

  • Amendment
    10 pages
    English language
    sale 10% off
    e-Library read for
    1 day

CISPR 11:2015 is available as <a href="https://webstore.iec.ch/publication/22635">CISPR 11:2015 RLV</a> which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.<br /><br /> CISPR 11:2015 applies to industrial, scientific and medical electrical equipment operating in the frequency range 0 Hz to 400 GHz and to domestic and similar appliances designed to generate and/or use locally radio-frequency energy. This standard covers emission requirements related to radio-frequency (RF) disturbances in the frequency range of 9 kHz to 400 GHz. Measurements need only be performed in frequency ranges where limits are specified in Clause 6. For ISM RF applications in the meaning of the definition found in the ITU Radio Regulations (see Definition 3.13), this standard covers emission requirements related to radio-frequency disturbances in the frequency range of 9 kHz to 18 GHz. Requirements for ISM RF lighting equipment and UV irradiators operating at frequencies within the ISM frequency bands defined by the ITU Radio Regulations are contained in this standard. Equipment covered by other CISPR product and product family emission standards are excluded from the scope of this standard. This sixth edition cancels and replaces the fifth edition published in 2009 and its Amendment 1 published in 2010. It constitutes a technical revision. It introduces and permits type testing on components of power electronic equipment, systems and installations. Its emission limits apply now to low voltage (LV) a.c. and d.c. power ports, irrespective of the direction of power transmission. Several limits were adapted to the practical test conditions found at test sites. They are also applicable now to power electronic ISM RF equipment used for wireless power transfer (WPT), for instant power supply and charging purposes. The limits in the range 1 GHz to 18 GHz apply now to CW-type disturbances and to fluctuating disturbances in a similar, uniform and technology-neutral way. For these measurements, two alternative methods of measurement are available, the traditional log-AV method and the new APD method. It has the status of a Product Family EMC standard in accordance with IEC Guide 107, Electromagnetic compatibility - Guide to the drafting of electromagnetic compatibility publications (2014).

  • Standard
    95 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of IEC 61000 defines the immunity test methods and range of recommended basic
test levels for electrical and electronic equipment with rated current up to 16 A per phase at
disturbance frequencies up to and including 2 kHz (for 50 Hz mains) and 2,4 kHz (for 60 Hz
mains) for harmonics and interharmonics on low voltage power networks.
It does not apply to electrical and electronic equipment connected to 16 2/3 Hz , or to 400 Hz
a.c. networks. Tests for these networks will be covered by future standards.
The object of this standard is to establish a common reference for evaluating the functional
immunity of electrical and electronic equipment when subjected to harmonics and interharmonics
and mains signalling frequencies. The test method documented in this part of IEC
61000 describes a consistent method to assess the immunity of an equipment or system
against a defined phenomenon. As described in IEC guide 107, this is a basic EMC publication
for use by product committees of the IEC. As also stated in Guide 107, the IEC product
committees are responsible for determining whether this immunity test standard should be
applied or not, and if applied, they are responsible for determining the appropriate test levels
and performance criteria. TC 77 and its sub-committees are prepared to co-operate with
product committees in the evaluation of the value of particular immunity tests for their products.
The verification of the reliability of electrical components (for example capacitors, filters, etc.)
is not in the scope of the present standard. Long term thermal effects (greater than 15 min) are
not considered in this standard.
The levels proposed are more adapted for residential, commercial and light industry
environments. For heavy industrial environments the product committees are responsible for
the definition of a class X with the necessary levels. They have also the possibility of defining
more complex waveforms for their own need. Nevertheless, the simple waveforms proposed
have been mainly observed on several networks (flat curve more often for single phase
system) and also on industrial networks (overswing curve more for three phase systems).

  • Amendment
    7 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 61000-4-16:2015 is available as IEC 61000-4-16:2015 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition. IEC 61000-4-16:2015 relates to the immunity requirements and test methods for electrical and electronic equipment to conducted, common mode disturbances in the range d.c. to 150 kHz. The object of this standard is to establish a common and reproducible basis for testing electrical and electronic equipment with the application of common mode disturbances to power supply, control, signal and communication ports. It has the status of a basic EMC publication in accordance with IEC Guide 107. This second edition cancels and replaces the first edition published in 1998, Amendment 1:2001 and Amendment 2:2009. This edition constitutes a technical revision.

  • Standard
    28 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Amendment to Table 15, widening the requirement for RF e.m. field (screening effectiveness) to DVB-C, -T & -S products

  • Amendment
    4 pages
    English language
    sale 10% off
    e-Library read for
    1 day