This part of IEC 61000 focuses on the immunity requirements and test methods for electrical and electronic equipment, under operational conditions, with regard to: a) repetitive slow damped oscillatory waves occurring mainly in power, control and signal cables installed in high voltage and medium voltage (HV/MV) substations; b) repetitive fast damped oscillatory waves occurring mainly in power, control and signal cables installed in gas insulated substations (GIS) and in some cases also air insulated substations (AIS) or in any installation due to high-altitude electromagnetic pulse (HEMP) phenomena. The object of this document is to establish a common and reproducible reference for evaluating the immunity of electrical and electronic equipment when subjected to damped oscillatory waves on supply, signal, control and earth ports. The test method documented in this part of IEC 61000 describes a consistent method to assess the immunity of an equipment or system against a defined phenomenon. NOTE As described in IEC Guide 107, this is a basic EMC publication for use by product committees of the IEC. As also stated in Guide 107, the IEC product committees are responsible for determining whether this immunity test standard is applied or not, and if applied, they are responsible for determining the appropriate test levels and performance criteria. 1 The document defines: – test voltage and current waveforms; – ranges of test levels; – test equipment; – calibration and verification procedures of test equipment; – test setups; – test procedure.

  • Standard
    60 pages
    English language
    sale 10% off
    e-Library read for
    1 day

NEW!IEC 61000-4-12:2017 is available as IEC 61000-4-12:2017 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 61000-4-12:2017 relates to the immunity requirements and test methods for electrical and electronic equipment, under operational conditions, to ring waves occurring in low-voltage power, control and signal lines supplied by public and non-public networks. The object of this document is to establish a common reference for evaluating the immunity of electrical and electronic equipment when subjected to ring waves. The test method documented in this part of IEC 61000 describes a consistent method to assess the immunity of an equipment or system against a defined phenomenon. It has the status of a basic EMC publication in accordance with IEC Guide 107. This edition includes the following significant technical changes with respect to the previous edition: a) addition of a mathematical modelling of ring wave waveform; b) new Annex B on selection of generators and test levels; c) new Annex C on explanatory notes; d) new Annex D on measurement uncertainty; e) addition of high speed CDN; f) addition of a calibration procedure for CDN.

  • Standard
    49 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 61000-4-39:2017 specifies immunity requirements for electrical and electronic equipment when it is exposed to radiated electromagnetic energy from RF transmitters used in close proximity. It establishes test levels and the required test procedures. The applicable frequency range is 9 kHz to 6 GHz. It has the status of a basic EMC publication in accordance with IEC Guide 107.

  • Standard
    43 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 61000-4-31:2016 relates to the conducted immunity of electrical and electronic equipment to electromagnetic disturbances coming from intended and/or unintended broadband signal sources in the frequency range 150 kHz up to 80 MHz. It has the status of a basic EMC publication in accordance with IEC Guide 107.

  • Standard
    46 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 61000-4-10:2016 is available as IEC 61000-4-10:2016 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition. IEC 61000-4-10:2016 specifies the immunity requirements, test methods, and range of recommended test levels for equipment subjected to damped oscillatory magnetic disturbances related to medium voltage and high voltage sub-stations. This second edition cancels and replaces the first edition published in 1993 and Amendment 1:2000. This edition constitutes a technical revision.

  • Standard
    44 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 61000-4-9:2016 is available as IEC 61000-4-9:2016 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition. IEC 61000-4-9:2016 specifies the immunity requirements, test methods, and range of recommended test levels for equipment subjected to impulse magnetic disturbances mainly encountered in industrial installations, power plants, railway installations, and medium voltage and high voltage sub-stations. This second edition cancels and replaces the first edition published in 1993 and Amendment 1:2000. This edition constitutes a technical revision.

  • Standard
    56 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 61000-4-5:2014 relates to the immunity requirements, test methods, and range of recommended test levels for equipment with regard to unidirectional surges caused by over-voltages from switching and lightning transients. Several test levels are defined which relate to different environment and installation conditions. These requirements are developed for and are applicable to electrical and electronic equipment. The object of this standard is to establish a common reference for evaluating the immunity of electrical and electronic equipment when subjected to surges. The test method documented describes a consistent method to assess the immunity of an equipment or system against a defined phenomenon. This standard defines a range of: - test levels; - test equipment; - test setups; and - test procedures. The task of the described laboratory test is to find the reaction of the equipment under test (EUT) under specified operational conditions to surge voltages caused by switching and lightning effects. It is not intended to test the capability of the EUT's insulation to withstand high-voltage stress. Direct injections of lightning currents, i.e. direct lightning strikes, are not considered in this standard. This third edition cancels and replaces the second edition published in 2005, and constitutes a technical revision which includes the following significant technical changes with respect to the previous edition: - a new Annex E on mathematical modelling of surge waveforms; - a new Annex F on measurement uncertainty; - a new Annex G on method of calibration of impulse measuring systems; and - a new Annex H on coupling/decoupling surges to lines rated above 200 A. Moreover while surge test for ports connected to outside telecommunication lines was addressed in 6.2 of the second edition (IEC 61000-4-5:2005), in this third edition (IEC 61000-4-5:2014) the normative Annex A is fully dedicated to this topic. In particular it gives the specifications of the 10/700 µs combined wave generator. Keywords: electromagnetic compatibility, EMC, TC77, SC77B

  • Standard
    78 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 61000-4-6:2013 relates to the conducted immunity requirements of electrical and electronic equipment to electromagnetic disturbances coming from intended radio-frequency (RF) transmitters in the frequency range 150 kHz up to 80 MHz. Equipment not having at least one conducting wire and/or cable (such as mains supply, signal line or earth connection) which can couple the equipment to the disturbing RF fields is excluded from the scope of this publication. The object of this standard is to establish a common reference for evaluating the functional immunity of electrical and electronic equipment when subjected to conducted disturbances induced by RF fields. The test method documented in IEC 61000-4-6:2013 describes a consistent method to assess the immunity of an equipment or system against a defined phenomenon. This fourth edition cancels and replaces the third edition published in 2008 and constitutes a technical revision. It includes the following significant technical changes with respect to the previous edition: - use of the CDNs; - calibration of the clamps; - reorganization of Clause 7 on test setup and injection methods; - Annex A which is now dedicated to EM and decoupling clamps; - Annex G which now addresses the measurement uncertainty of the voltage test level; - and informative Annexes H, I and J which are new.

  • Standard
    86 pages
    English language
    sale 10% off
    e-Library read for
    1 day

NEW! IEC 61000-4-4:2012 is available as IEC Standards+ 61000-4-4:2012 which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition. IEC 61000-4-4:2012 relates to the immunity of electrical and electronic equipment to repetitive electrical fast transients. It has the status of a basic EMC publication in accordance with IEC Guide 107. It gives immunity requirements and test procedures related to electrical fast transients/bursts. It additionally defines ranges of test levels and establishes test procedures. The object of this standard is to establish a common and reproducible reference in order to evaluate the immunity of electrical and electronic equipment when subjected to electrical fast transient/bursts on supply, signal, control and earth ports. The test method documented in this standard describes a consistent method to assess the immunity of an equipment or system against a defined phenomenon. This third edition cancels and replaces the second edition published in 2004 and its amendment 1 (2010). It constitutes a technical revision which improves and clarifies simulator specifications, test criteria and test setups.

  • Standard
    46 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 61000-4-21:2011 considers tests of immunity and intentional or unintentional emissions for electric and/or electronic equipment and tests of screening effectiveness in reverberation chambers. It establishes the required test procedures for performing such tests. Only radiated phenomena are considered. The objective of IEC 61000-4-21:2011 is to establish a common reference for using reverberation chambers to evaluate the performance of electric and electronic equipment when subjected to radio-frequency electromagnetic fields and for determining the levels of radio-frequency radiation emitted from electric and electronic equipment. IEC 61000-4-21:2011 does not intend to specify the tests to be applied to a particular apparatus or system. Its main aim is to give a general basic reference to all concerned product committees of the IEC. The product committees should select emission limits and test methods in consultation with CISPR. The product committees remain responsible for the appropriate choice of the immunity tests and the immunity test limits to be applied to their equipment. Other methods, such as those covered in IEC 61000-4-3, CISPR 16-2-3 and CISPR 16-2-4 may be used. This second edition cancels and replaces the first edition published in 2003. This edition constitutes a technical revision and includes the following significant technical changes with respectto the first edition: - In Clause 8, the use and specifications of E-field probes for application to reverberation chambers has been added. - In Annex A, additional guidance and clarifications on the use of reverberation chambers at relatively low frequencies of operation (i.e., close to the lowest usable frequency of a given chamber) are given, and its implications on the estimation of field uncertainty are outlined. - In Annex B, symmetric location of the field probes when the chamber exhibits cylindrical symmetry has been disallowed, as such placement could otherwise yield a false indication of field uniformity and chamber performance at different locations. - Annex C now contains more quantitative guidance on the setting of the maximum permissible stirring speeds that warrant quasi-static conditions of operation for chamber validation and testing. - In Annex D, a requirement for the EUT and equipment not to occupy more than 8 % of the total chamber volume in immunity testing has been added. - Annex E has been extended with further guidance on the value of EUT directivity to be used in the estimation of radiated power and field. - In Annex I, some clarifications on antenna efficiency measurements have been added. - A new Annex K has been added that covers measurement uncertainty in reverberation chambers.

  • Standard
    112 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 61000-4-20:2010 relates to emission and immunity test methods for electrical and electronic equipment using various types of transverse electromagnetic (TEM) waveguides. These types include open structures (for example, striplines and electromagnetic pulse simulators) and closed structures (for example, TEM cells). These structures can be further classified as one-, two-, or multi-port TEM waveguides. The frequency range depends on the specific testing requirements and the specific TEM waveguide type. The object of this standard is to describe: - TEM waveguide characteristics, including typical frequency ranges and EUT-size limitations; - TEM waveguide validation methods for EMC tests; - the EUT (i.e. EUT cabinet and cabling) definition; - test set-ups, procedures, and requirements for radiated emission testing in TEM waveguides and - test set-ups, procedures, and requirements for radiated immunity testing in TEM waveguides. IEC 61000-4-20:2010 does not intend to specify the tests to be applied to any particular apparatus or system(s). The main intention of this standard is to provide a general basic reference for all interested product committees of the IEC. For radiated emissions testing, product committees should select emission limits and test methods in consultation with CISPR standards. For radiated immunity testing, product committees remain responsible for the appropriate choice of immunity tests and immunity test limits to be applied to equipment within their scope. This standard describes test methods that are separate from those of IEC 61000-4-3. This second edition cancels and replaces the first edition published in 2003 and its amendment 1 (2006), and constitutes a technical revision. It has the status of a basic EMC publication in accordance with IEC Guide 107. The main changes with respect to the first edition of this standard and its amendment are the following: - consistency of terms (e.g. test, measurement, etc.) has been improved; - clauses covering test considerations, evaluations and the test report have been added; - references to large TEM waveguides have been eliminated; - a new informative annex has been added to deal with calibration of E-field probes.

  • Standard
    78 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of IEC 61000-4 relates to the immunity requirements and test methods for electrical and electronic equipment, under operational conditions, with regard to: a) repetitive damped oscillatory waves occurring mainly in power, control and signal cables installed in high voltage and medium voltage (HV/MV) substations; b) repetitive damped oscillatory waves occurring mainly in power, control and signal cables installed in gas insulated substations (GIS) and in some cases also air insulated substations (AIS) or in any installation due to HEMP phenomena. The object of this basic standard is to establish the immunity requirements and a common reference for evaluating in a laboratory the performance of electrical and electronic equipment intended for residential, commercial and industrial applications, as well as of equipment intended for power stations and substations, as applicable.

  • Amendment
    4 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Amandma A2:2011 je dodatek k standardu SIST EN 61000-4-3:2006.
This part of IEC 61000 is applicable to the immunity requirements of electrical and electronic equipment to radiated electromagnetic energy. It establishes test levels and the required test procedures. The object of this standard is to establish a common reference for evaluating the immunity of electrical and electronic equipment when subjected to radiated, radio-frequency electromagnetic fields. The test method documented in this part of IEC 61000 describes a consistent method to assess the immunity of an equipment or system against a defined phenomenon. NOTE 1 As described in IEC Guide 107, this is a basic EMC publication for use by product committees of the IEC. As also stated in Guide 107, the IEC product committees are responsible for determining whether this immunity test standard should be applied or not, and if applied, they are responsible for determining the appropriate test levels and performance criteria. TC 77 and its sub-committees are prepared to co-operate with product committees in the evaluation of the value of particular immunity tests for their products. This part deals with immunity tests related to the protection against RF electromagnetic fields from any source. Particular considerations are devoted to the protection against radio-frequency emissions from digital radiotelephones and other RF emitting devices. NOTE 2 Test methods are defined in this part for evaluating the effect that electromagnetic radiation has on the equipment concerned. The simulation and measurement of electromagnetic radiation is not adequately exact for quantitative determination of effects. The test methods defined are structured for the primary objective of establishing adequate repeatability of results at various test facilities for qualitative analysis of effects. This standard is an independent test method. Other test methods may not be used as substitutes for claiming compliance with this standard.

  • Amendment
    8 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 61000-4-2:2008 relates to the immunity requirements and test methods for electrical and electronic equipment subjected to static electricity discharges, from operators directly, and from personnel to adjacent objects. It additionally defines ranges of test levels which relate to different environmental and installation conditions and establishes test procedures. The object of IEC 61000-4-2:2008 is to establish a common and reproducible basis for evaluating the performance of electrical and electronic equipment when subjected to electrostatic discharges. In addition, it includes electrostatic discharges which may occur frompersonnel to objects near vital equipment. IEC 61000-4-2:2008 defines typical waveform of the discharge current, range of test levels, test equipment, test setup, test procedure, calibration procedure and measurement uncertainty. IEC 61000-4-2:2008 gives specifications for test performed in "laboratories" and "post-installation tests" performed on equipment in the final installation. This second edition cancels and replaces the first edition published in 1995, its amendment 1 (1998) and its amendment 2 (2000) and constitutes a technical revision. It has the status of a basic EMC publication in accordance with IEC Guide 107. The main changes with respect to the first edition of this standard and its amendments are the following: - the specifications of the target have been extended up to 4 GHz. An example of target matching these requirements is also provided; - information on radiated fields from human-metal discharge and from ESD generators is provided; - measurement uncertainty considerations with examples of uncertainty budgets are given too.

  • Standard
    66 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of IEC 61000-4 relates to the immunity requirements and test methods for electrical and electronic equipment, under operational conditions, with regard to: a) repetitive damped oscillatory waves occurring mainly in power, control and signal cables installed in high voltage and medium voltage (HV/MV) substations; b) repetitive damped oscillatory waves occurring mainly in power, control and signal cables installed in gas insulated substations (GIS) and in some cases also air insulated substations (AIS) or in any installation due to HEMP phenomena. The object of this basic standard is to establish the immunity requirements and a common reference for evaluating in a laboratory the performance of electrical and electronic equipment intended for residential, commercial and industrial applications, as well as of equipment intended for power stations and substations, as applicable. The purpose of this standard is to define: - test voltage and current waveforms; - ranges of test levels; - test equipment; - test setup; - test procedure. The object of this standard is to establish a common reference for evaluating the immunity of electrical and electronic equipment when subjected to damped oscillatory waves. The test method documented in this part of IEC 61000 describes a consistent method to assess the immunity of an equipment or system against a defined phenomenon. It has the status of a basic EMC publication in accordance with IEC Guide 107.

  • Standard
    39 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 61000-4-3:2020 is applicable to the immunity requirements of electrical and electronic equipment to radiated electromagnetic energy. It establishes test levels and the required test procedures. The object of this document is to establish a common reference for evaluating the immunity of electrical and electronic equipment when subjected to radiated, radio-frequency electromagnetic fields. The test method documented in this part of IEC 61000 describes a consistent method to assess the immunity of an equipment or system against RF electromagnetic fields from RF sources not in close proximity to the EUT. The test environment is specified in Clause 6. NOTE 1 As described in IEC Guide 107, this is a basic EMC publication for use by product committees of the IEC. As also stated in Guide 107, the IEC product committees are responsible for determining whether this immunity test standard should be applied or not, and if applied, they are responsible for determining the appropriate test levels and performance criteria. TC 77 and its sub-committees are prepared to co-operate with product committees in the evaluation of the value of particular immunity tests for their products. NOTE 2 Immunity testing against RF sources in close proximity to the EUT is defined in IEC 61000-4-39. Particular considerations are devoted to the protection against radio-frequency emissions from digital radiotelephones and other RF emitting devices. NOTE 3 Test methods are defined in this part for evaluating the effect that electromagnetic radiation has on the equipment concerned. The simulation and measurement of electromagnetic radiation is not adequately exact for quantitative determination of effects. The test methods defined in this basic document have the primary objective of establishing an adequate reproducibility of testing configuration and repeatability of test results at various test facilities. This document is an independent test method. It is not possible to use other test methods as substitutes for claiming compliance with this document. This fourth edition cancels and replaces the third edition published in 2006, Amendment 1:2007 and Amendment 2:2010. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: - testing using multiple test signals has been described; - additional information on EUT and cable layout has been added; - the upper frequency limitation has been removed to take account of new services; - the characterization of the field as well as the checking of power amplifier linearity of the immunity chain are specified.

  • Standard
    84 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Is applicable to the immunity requirements of electrical and electronic equipment to radiated electromagnetic energy. It establishes test levels and the required test procedures. The object of this standard is to establish a common reference for evaluating the immunity of electrical and electronic equipment when subjected to radiated, radio-frequency electromagnetic fields. The test method documented in this part of IEC 61000 describes a consistent method to assess the immunity of an equipment or system against a defined phenomenon. This part deals with immunity tests related to the protection against RF electromagnetic fields from any source. Particular considerations are devoted to the protection against radio-frequency emissions from digital radiotelephones and other RF emitting devices. It has the status of a basic EMC publication.

  • Standard
    59 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Establishes a common and reproducible reference for evaluating the immunity of electrical and electronic equipment when subjected to electrical fast transient/bursts on supply, signal, control and earth ports. The test method documented in this part of IEC 61000-4 describes a consistent method to assess the immunity of an equipment or system against a defined phenomenon.

  • Amendment
    5 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 61000-4-6:2008 relates to the conducted immunity requirements of electrical and electronic equipment to electromagnetic disturbances coming from intended radio-frequency (RF) transmitters in the frequency range 9 kHz up to 80 MHz. Equipment not having at least one conducting cable (such as mains supply, signal line or earth connection) which can couple the equipment to the disturbing RF fields is excluded. The object of IEC 61000-4-6:2008 is to establish a common reference for evaluating the functional immunity of electrical and electronic equipment when subjected to conducted disturbances induced by radio-frequency fields. The test method documented in this part of IEC 61000 describes a consistent method to assess the immunity of an equipment or system against a defined phenomenon. IEC 61000-4-6:2008 has the status of a basic EMC publication in accordance with IEC Guide 107. This third edition of IEC 61000-4-6:2008 cancels and replaces the second edition published in 2003, Amendment 1 (2004) and Amendment 2 (2006). This edition constitutes a technical revision. NEW! IEC 61000-4-6:2008 is also available as IEC Standards+ 61000-4-6:2008 which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.

  • Standard
    59 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Superseded by EN 61000-4-20:2010

  • Amendment
    8 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Amendment
    4 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of IEC 61000 relates to the immunity requirements and test methods for electrical and electronic equipment, under operational conditions, to non-repetitive damped oscillatory transients (ring waves) occurring in low-voltage power, control and signal lines supplied by public and non-public networks. The object of this basic standard is to establish the immunity requirements and a common reference for evaluating in a laboratory the performance of electrical and electronic equipment intended for residential, commercial and industrial applications, as well as of equipment intended for power stations and substations, as applicable. The purpose of this standard is to define: - test voltage and current waveforms; - ranges of test levels; - test equipment; - test set-up; - test procedure.

  • Standard
    35 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Relates to the immunity requirements, test methods, and range of recommended test levels for equipment to unidirectional surges caused by overvoltages from switching and lightning transients. Several test levels are defined which relate to different environment and installation conditions. These requirements are developed for and are applicable to electrical and electronic equipment. The object of this standard is to establish a common reference for evaluating the immunity of electrical and electronic equipment when subjected to surges. The test method documented in this part of IEC 61000 describes a consistent method to assess the immunity of an equipment or system against a defined phenomenon. This standard defines: - a range of test levels; - test equipment; - test setups; - test procedures. The task of the described laboratory test is to find the reaction of the EUT under specified operational conditions, to surge voltages caused by switching and lightning effects at certain threat levels. It is not intended to test the capability of the EUT's insulation to withstand high-voltage stress. Direct injections of lightning currents, i.e, direct lightning strikes, are not considered in this standard. It has the status of a basic EMC publication in accordance with IEC Guide 107.

  • Standard
    51 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Establishes a common and reproducible reference for evaluating the immunity of electrical and electronic equipment when subjected to electrical fast transient/bursts on supply, signal, control and earth ports. The test method documented in this part of EN 61000-4 describes a consistent method to assess the immunity of an equipment or system against a defined phenomenon. The standard defines: - test voltage waveform; - range of test levels; - test equipment; - verification procedures of test equipment; - test set-up; - test procedure. The standard gives specifications for laboratory and post-installation tests. This second edition cancels and replaces the first edition published in 1995 and its amendments 1 (2000) and 2 (2001) and constitutes a technical revision.

  • Standard
    35 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Relates to the conducted immunity requirements of electrical and electronic equipment to electromagnetic disturbances coming from intended radio-frequency (RF) transmitters in the frequency range 9 kHz up to 80 MHz. Equipment not having at least one conducting cable (such as mains supply, signal line or earth connection), which can couple the equipment to the disturbing RF fields is excluded. This standard does not intend to specify the tests to be applied to particular apparatus or systems. Its main aim is to give a general basic reference to all concerned product committes of the IEC. The product committees (or users and manufacturers of equipment) remain responsible for the appropriate choice of the test and the severity level to be applied to their equipment.

  • Addendum
    1 page
    English language
    sale 10% off
    e-Library read for
    1 day

Applies to the immunity of electrical and electronic equipment to radiated electromagnetic energy. Establishes test levels and the required test procedures. Establishes a common reference for evaluating the performance of electrical and electronic equipment when subjected to radio-frequency electromagnetic fields.

  • Addendum
    1 page
    English language
    sale 10% off
    e-Library read for
    1 day

Relates to emission and immunity test methods for electrical and electronic equipment using various types of transverse electromagnetic (TEM) waveguides. This includes open (for example, striplines and EMP simulators) and closed (for example, TEM cells) structures, which can be further classified as one-, two-, or multi-port TEM waveguides. The frequency range depends on the specific testing requirements and the specific TEM waveguide type. The object of this standard is to describe · TEM waveguide characteristics, including typical frequency ranges and EUT-size limitations (EUT = equipment under test); · TEM waveguide validation methods for EMC measurements; · the EUT (i.e. EUT cabinet and cabling) definition; · test set-ups, procedures, and requirements for radiated emission testing in TEM waveguides and · test set-ups, procedures, and requirements for radiated immunity testing in TEM waveguides.

  • Standard
    69 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Applies to the immunity of electrical and electronic equipment to radiated electromagnetic energy. Establishes test levels and the required test procedures. Establishes a common reference for evaluating the performance of electrical and electronic equipment when subjected to radio-frequency electromagnetic fields.

  • Standard
    49 pages
    English language
    sale 10% off
    e-Library read for
    1 day

EN following parallel vote * Superseded by EN 61000-4-12:2006 & EN 61000-4-18:2007

  • Amendment
    5 pages
    English language
    sale 10% off
    e-Library read for
    1 day

EN following parallel vote * Incorporates AA ratified at 96 BT * Superseded by EN 61000-4-3:2002

  • Amendment
    39 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Applies to the immunity of electrical and electronic equipment to radiated electromagnetic energy. Establishes test levels and the required test procedures. Establishes a common reference for evaluating the performance of electrical and electronic equipment when subjected to radio-frequency electromagnetic fields.

  • Standard
    33 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Relates to the conducted immunity requirements of electrical and electronic equipment to electromagnetic disturbances coming from intended radio-frequency (RF) transmitters in the frequency range 9 kHz up to 80 MHz. Equipment not having at least one conducting cable (such as mains supply, signal line or earth connection), which can couple the equipment to the disturbing RF fields is excluded. This standard does not intend to specify the tests to be applied to particular apparatus or systems. Its main aim is to give a general basic reference to all concerned product committes of the IEC. The product committees (or users and manufacturers of equipment) remain responsible for the appropriate choice of the test and the severity level to be applied to their equipment.

  • Standard
    47 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This basic standard establishes the immunity requirements and a common reference for evaluating in a laboratory the performance of electrical and electronic equipment intended for residential, commercial and industrial application, as well as of equipment intended for electrical stations, as applicable. The purpose of this standard is to define: - test voltage and current waveforms; - ranges of test levels; - test equipment; - test set-up; - test procedure.

  • Standard
    46 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This publication is based on EN 60801-2 (second edition: 1991). It relates to the immunity requirements and test methods for electrical and electronic equipment subjected to static electricity discharges, from operators directly, and to adjacent objects. It additionally defines ranges of test levels which relate to different environmental and installation conditions and establishes test procedures. The object of this standard is to establish a common and reproducible basis for evaluating the performance of electrical and electronic equipment when subjected to electrostatic discharges. In addition, it includes electrostatic discharges which may occur from personnel to objects near vital equipment.

  • Standard
    39 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Relates to the immunity requirements and test methods for electrical and electronic equipment to repetitive electrical fast transients. Additionally defines ranges of test levels and establishes test procedures. The object of this standard is to establish a common and reproducible basis for evaluating the performance of electrical and electronic equipment when subjected to repetitive fast transients (bursts), on supply, signal and control ports. The test is intended to demonstrate the immunity of electrical and electronic equipment when subjected to types of transient disturbances such as those originating from switching transients (interruption of inductive loads, relay contact bounce, etc.). The standard defines: - test voltage waveform; - range of test levels; - test equipment; - test set-up; - test procedure.

  • Standard
    34 pages
    English language
    sale 10% off
    e-Library read for
    1 day