Lamp controlgear - Part 2-10: Particular requirements for electronic invertors and convertors for high-frequency operation of cold start tubular discharge lamps (neon tubes)

This part of EN 61347 specifies general and safety requirements for lamp controlgear for use on d.c. supplies up to 250 V and/or a.c. supplies up to 1 000 V at 50 Hz or 60 Hz. This standard also covers lamp controlgear for lamps which are not yet standardized. Tests dealt with in this standard are type tests. Requirements for testing individual lamp controlgear during production are not included. This part 1 is to be used in conjunction with the appropriate part 2, which contains clauses to supplement or modify the corresponding clauses in part 1, to provide the relevant requirements for each type of product. This first edition of EN 61347-1, together with parts 1 to 9 of EN 61347-2, cancels and replaces EN 60920, EN 60922, EN 60924, EN 60926, EN 60928 and EN 61046, and constitute a minor revision. The relationship between the parts that make up EN 61347-2 and the IEC standards they replace is detailed as follows: EN 61347-2-1 replaces EN 60926 EN 61347-2-2 replaces EN 61046 EN 61347-2-3 replaces EN 60928 EN 61347-2-4 replaces EN 60924, Section 3 EN 61347-2-5 replaces EN 60924, Section 4 EN 61347-2-6 replaces EN 60924, Section 5 EN 61347-2-7 replaces EN 60924, Section 6 EN 61347-2-8 replaces EN 60920 EN 61347-2-9 replaces EN 60922

Geräte für Lampen - Teil 2-10: Besondere Anforderungen an elektronische Wechselrichter und Konverter für Hochfrequenzbetrieb von röhrenförmigen Kaltstart-Entladungslampen (Neonröhren)

Appareillages de lampes - Partie 2-10: Prescriptions particulières pour onduleurs et convertisseurs électroniques destinés à l'alimentation en haute fréquence des lampes tubulaires à décharge à démarrage à froid (tubes néon)

La présente partie de la EN 61347 spécifie les prescriptions générales et les prescriptions de sécurité pour les appareillages de lampes destinés à être utilisés sur des alimentations à courant continu jusqu'à 250 V et/ou sur des alimentations à courant alternatif jusqu'à 1000 V à 50 Hz ou 60 Hz. La présente norme traite aussi des appareillages de lampes pour les lampes qui ne sont pas encore normalisées. Les essais traités dans cette norme sont des essais de type. Les prescriptions pour les essais individuels des appareillages de lampes pendant la production ne sont pas incluses. La présente partie 1 doit être utilisée conjointement avec la partie 2 appropriée, qui comporte les articles complétant ou modifiant les articles correspondants de la partie 1, afin d'établir les règles complètes pour chaque type d'appareil. Cette première édition de la EN 61347-1, ainsi que les parties 1 à 9 de la EN 61347-2 annulent et remplacent la EN 60920, la EN 60922, la EN 60924, la EN 60926, la EN 60928, et la EN 61046, et constituent une révision mineure. La correspondance entre les parties composant la EN 61347-2 et les normes qu'elles remplacent est détaillée ci-dessous: la EN 61347-2-1 remplace la EN 60926 la EN 61347-2-2 remplace la EN 61046 la EN 61347-2-3 remplace la EN 60928 la EN 61347-2-4 remplace la EN 60924, Section 3 la EN 61347-2-5 remplace la EN 60924, Section 4 la EN 61347-2-6 remplace la EN 60924, Section 5 la EN 61347-2-7 remplace la EN 60924, Section 6 la EN 61347-2-8 remplace la EN 60920 la EN 61347-2-9 remplace la EN 60922

Lamp controlgear – Part 2-10: Particular requirements for electronic invertors and convertors for high-frequency operation of cold start tubular discarge lamps (neon tubes) (IEC 61347-2-10:2000)

General Information

Status
Published
Publication Date
21-Jan-2001
Withdrawal Date
31-Oct-2003
Drafting Committee
Parallel Committee
Current Stage
6060 - Document made available - Publishing
Completion Date
22-Jan-2001

Relations

Buy Standard

Standard
EN 61347-2-10:2002
English language
25 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)


SLOVENSKI STANDARD
01-december-2002
Lamp controlgear – Part 2-10: Particular requirements for electronic invertors and
convertors for high-frequency operation of cold start tubular discarge lamps (neon
tubes) (IEC 61347-2-10:2000)
Lamp controlgear -- Part 2-10: Particular requirements for electronic invertors and
convertors for high-frequency operation of cold start tubular discharge lamps (neon
tubes)
Geräte für Lampen -- Teil 2-10: Besondere Anforderungen an elektronische
Wechselrichter und Konverter für Hochfrequenzbetrieb von röhrenförmigen Kaltstart-
Entladungslampen (Neonröhren)
Appareillages de lampes -- Partie 2-10: Prescriptions particulières pour onduleurs et
convertisseurs électroniques destinés à l'alimentation en haute fréquence des lampes
tubulaires à décharge à démarrage à froid (tubes néon)
Ta slovenski standard je istoveten z: EN 61347-2-10:2001
ICS:
29.130.01 Stikalne in krmilne naprave Switchgear and controlgear
na splošno in general
29.140.99 Drugi standardi v zvezi z Other standards related to
žarnicami lamps
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

EUROPEAN STANDARD EN 61347-2-10
NORME EUROPÉENNE
EUROPÄISCHE NORM January 2001
ICS 29.140.99
English version
Lamp controlgear
Part 2-10: Particular requirements for electronic invertors
and convertors for high-frequency operation of
cold start tubular discharge lamps (neon tubes)
(IEC 61347-2-10:2000)
Appareillages de lampes Geräte für Lampen
Partie 2-10: Prescriptions particulières Teil 2-10: Besondere Anforderungen
pour onduleurs et convertisseurs an elektronische Wechselrichter und
électroniques destinés à l'alimentation Konverter für Hochfrequenzbetrieb
en haute fréquence des lampes tubulaires von röhrenförmigen Kaltstart-
à décharge à démarrage à froid Entladungslampen (Neonröhren)
(tubes néon) (IEC 61347-2-10:2000)
(CEI 61347-2-10:2000)
This European Standard was approved by CENELEC on 2000-11-01. CENELEC members are bound
to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this
European Standard the status of a national standard without any alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on
application to the Central Secretariat or to any CENELEC member.
This European Standard exists in three official versions (English, French, German). A version in any other
language made by translation under the responsibility of a CENELEC member into its own language and
notified to the Central Secretariat has the same status as the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Czech Republic,
Denmark, Finland, France, Germany, Greece, Iceland, Ireland, Italy, Luxembourg, Netherlands, Norway,
Portugal, Spain, Sweden, Switzerland and United Kingdom.
CENELEC
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
Central Secretariat: rue de Stassart 35, B - 1050 Brussels
© 2001 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.
Ref. No. EN 61347-2-10:2001 E
Foreword
The text of document 34C/507/FDIS, future edition 1 of IEC 61347-2-10, prepared by SC 34C,
Auxiliaries for lamps, of IEC TC 34, Lamps and related equipment, was submitted to the IEC-
CENELEC parallel vote and was approved by CENELEC as EN 61347-2-10 on 2000-11-01.
The following dates were fixed:
– latest date by which the EN has to be implemented
at national level by publication of an identical
national standard or by endorsement (dop) 2001-08-01
– latest date by which the national standards conflicting
with the EN have to be withdrawn (dow) 2003-11-01
This standard shall be used in conjunction with EN 61347-1:2001.
NOTE In this standard, the following print types are used:
- requirements : in roman type;
- test specifications: in italic type;
- notes: in smaller roman type.
Annexes designated "normative" are part of the body of the standard.
In this standard, annexes A to F, H, I and ZA are normative.
Annex ZA has been added by CENELEC.
__________
Endorsement notice
The text of the International Standard IEC 61347-2-10:2000 was approved by CENELEC as a
European Standard without any modification.
__________
- 3 - EN 61347-2-10:2001
Annex ZA
(normative)
Normative references to international publications
with their corresponding European publications
This European Standard incorporates by dated or undated reference, provisions from other
publications. These normative references are cited at the appropriate places in the text and the
publications are listed hereafter. For dated references, subsequent amendments to or revisions of
any of these publications apply to this European Standard only when incorporated in it by
amendment or revision. For undated references the latest edition of the publication referred to
applies (including amendments).
NOTE When an international publication has been modified by common modifications, indicated by (mod), the relevant
EN/HD applies.
Publication Year Title EN/HD Year
IEC 61347-1 2000 Lamp controlgear EN 61347-1 2001
Part 1: General and safety requirements
ISO 3864 1984 Safety colours and safety signs - -

NORME CEI
INTERNATIONALE IEC
61347-2-10
INTERNATIONAL
Première édition
STANDARD
First edition
2000-10
Appareillages de lampes –
Partie 2-10:
Prescriptions particulières pour onduleurs
et convertisseurs électroniques destinés
à l'alimentation en haute fréquence des lampes
tubulaires à décharge à démarrage à froid
(tubes néon)
Lamp controlgear –
Part 2-10:
Particular requirements for electronic invertors
and convertors for high-frequency operation
of cold start tubular discharge lamps (neon tubes)
 IEC 2000 Droits de reproduction réservés  Copyright - all rights reserved
Aucune partie de cette publication ne peut être reproduite ni No part of this publication may be reproduced or utilized in
utilisée sous quelque forme que ce soit et par aucun procédé, any form or by any means, electronic or mechanical,
électronique ou mécanique, y compris la photocopie et les including photocopying and microfilm, without permission in
microfilms, sans l'accord écrit de l'éditeur. writing from the publisher.
International Electrotechnical Commission 3, rue de Varembé Geneva, Switzerland
Telefax: +41 22 919 0300 e-mail: inmail@iec.ch IEC web site http://www.iec.ch
CODE PRIX
Commission Electrotechnique Internationale
S
PRICE CODE
International Electrotechnical Commission
Pour prix, voir catalogue en vigueur
For price, see current catalogue

61347-2-10  IEC:2000 – 3 –
CONTENTS
Page
FOREWORD . 5
INTRODUCTION .9
Clause
1 Scope . 11
2 Normative references. 13
3 Definitions. 13
4 General requirements . 15
5 General notes on tests. 15
6 Classification .15
7 Marking. 17
7.1 Item to be marked. 17
7.2 Durability and legibility of marking . 17
8 Terminals. 19
9 Provisions for earthing . 19
10 Protection against accidental contact with live parts. 19
11 Moisture resistance and insulation . 21
12 Electric strength.21
13 Thermal endurance test for windings. 21
14 Normal conditions . 21
15 Abnormal conditions . 23
16 Fault conditions . 23
17 Construction .25
18 Creepage distances and clearances. 25
19 Protective circuits . 27
20 Screws, current-carrying parts and connections . 29
21 Resistance to heat, fire and tracking . 29
22 Resistance to corrosion. 29
23 No-load rated output voltage and rated output current. 31
23.1 No-load rated output voltage. 31
23.2 Rated output current . 31
23.3 Compliance. 31
Annexes . 33

61347-2-10  IEC:2000 – 5 –
INTERNATIONAL ELECTROTECHNICAL COMMISSION
–––––––––––
LAMP CONTROLGEAR –
Part 2-10: Particular requirements for electronic invertors
and convertors for high-frequency operation of cold start
tubular discharge lamps (neon tubes)
FOREWORD
1) The IEC (International Electrotechnical Commission) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of the IEC is to promote
international co-operation on all questions concerning standardization in the electrical and electronic fields. To
this end and in addition to other activities, the IEC publishes International Standards. Their preparation is
entrusted to technical committees; any IEC National Committee interested in the subject dealt with may
participate in this preparatory work. International, governmental and non-governmental organizations liaising
with the IEC also participate in this preparation. The IEC collaborates closely with the International
Organization for Standardization (ISO) in accordance with conditions determined by agreement between the
two organizations.
2) The formal decisions or agreements of the IEC on technical matters express, as nearly as possible, an
international consensus of opinion on the relevant subjects since each technical committee has representation
from all interested National Committees.
3) The documents produced have the form of recommendations for international use and are published in the form
of standards, technical specifications, technical reports or guides and they are accepted by the National
Committees in that sense.
4) In order to promote international unification, IEC National Committees undertake to apply IEC International
Standards transparently to the maximum extent possible in their national and regional standards. Any
divergence between the IEC Standard and the corresponding national or regional standard shall be clearly
indicated in the latter.
5) The IEC provides no marking procedure to indicate its approval and cannot be rendered responsible for any
equipment declared to be in conformity with one of its standards.
6) Attention is drawn to the possibility that some of the elements of this International Standard may be the subject
of patent rights. The IEC shall not be held responsible for identifying any or all such patent rights.
International Standard IEC 61347-2-10 has been prepared by subcommittee 34C: Auxiliaries
for lamps, of IEC technical committee 34: Lamps and related equipment.
This standard shall be used in conjunction with IEC 61347-1. It was established on the basis
of the first edition (2000) of that standard.
This part 2 supplements or modifies the corresponding clauses in IEC 61347-1, so as to
convert that publication into the IEC Standard: Particular requirements for electronic invertors
and convertors for high-frequency operation of cold start tubular discharge lamps (neon
tubes)
NOTE In this standard, the following print types are used:
– Requirements proper: in roman type.
– Test specifications: in italic type.
– NOTES: Explanatory matter: in smaller roman type.

61347-2-10  IEC:2000 – 7 –
The text of this standard is based on the following documents:
FDIS Report on voting
34C/507/FDIS 34C/521/RVD
Full information on the voting for the approval of this standard can be found in the report on
voting indicated in the above table.
This publication has been drafted in accordance with the ISO/IEC Directives, Part 3.
Annexes A, B, C, D, E, F, H and I form an integral part of this standard.
IEC 61347 consists of the following parts, under the general title: Lamp controlgear:
– Part 1: General and safety requirements
– Part 2-1: Particular requirements for starting devices (other than glow starters)
– Part 2-2: Particular requi
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.