EN 62305-4:2011/AC:2016-11
(Corrigendum)Protection against lightning - Part 4: Electrical and electronic systems within structures
- BACK
- 03-Nov-2016
- 29.020
- 91.120.40
- CLC/TC 81X
Protection against lightning - Part 4: Electrical and electronic systems within structures
Corrigendum to delete the mention of "modified" from IEC reference document and to add a correction in Annex ZA
Blitzschutz -Teil 4: Elektrische und elektronische Systeme in baulichen Anlagen
Protection contre la foudre - Partie 4: Réseaux de puissance et de communication dans les structures
Zaščita pred delovanjem strele - 4. del: Električni in elektronski sistemi v zgradbah - Popravek AC
General Information
Relations
Standards Content (Sample)
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Blitzschutz -Teil 4: Elektrische und elektronische Systeme in baulichen AnlagenProtection contre la foudre - Partie 4: Réseaux de puissance et de communication dans les structuresProtection against lightning - Part 4: Electrical and electronic systems within structures91.120.40Lightning protectionICS:Ta slovenski standard je istoveten z:EN 62305-4:2011/AC:2016-11SIST EN 62305-4:2011/AC:2016en
...
This May Also Interest You
IEC 62305-3:2024 provides the requirements for protection of a structure against physical damage by means of a lightning protection system (LPS), and for protection against injury to human beings due to touch and step voltages in the vicinity of an LPS (see IEC 62305-1). This document is applicable to the: a) design, installation, inspection and maintenance of an LPS for structures without limitation of their height, b) establishment of measures for protection against injury to human beings primarily due to touch and step voltages. This third edition cancels and replaces the second edition published in 2010. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) Minimum thicknesses of metal sheets or metal pipes are given in Table 4 for air-termination systems where it is necessary to prevent hot-spot problems. Maximum temperature rises ΔT (K) and time duration t50 (s) for different thicknesses and long strokes are also given. b) Cross-reference to the IEC 62561 series is made for the use of reliable, stable, safe and appropriate LPS components. c) The application of two methods – general and simplified – for separation distance calculation is clarified. d) Some changes to the requirements for continuity of steel reinforcement are made. e) Annex C is revised to address comments from IEC subcommittee 31J. f) Revision of positioning of air-termination conductors are modified according to the three accepted methods. A more precise description of the methods for positioning of the air-termination systems are made according to the complexity of structures to be protected. The main text has been simplified, Annex A has been deleted and all detailed information has been moved to Annex D. g) Information on the protection of green roofs is introduced in Annex D. h) Information on the protection of protruding parts on facades of tall buildings is introduced in Annex D. i) a new definition of “electrically insulated LPS” has been introduced to distinguish it from an LPS both electrically and physically isolated from the structure, with a slight modification of the other LPS definitions.
- Draft135 pagesEnglish languagesale 10% offe-Library read for×1 day
- 24-Oct-2024
- 18-Aug-2019
- 29.020
- 91.120.40
- CLC/TC 81X
IEC 62305-2:2024 is applicable to the risk management of a structure due to lightning flashes to earth. Its purpose is to provide a procedure for the evaluation of such a risk. Once an upper tolerable limit for the risk has been selected, this procedure provides a means for the selection of appropriate protection measures to be adopted to reduce the risk to or below the tolerable limit. This third edition cancels and replaces the second edition, published in 2010. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) The concept of a single risk, to combine loss of human life and loss due to fire, has been introduced. b) The concept of frequency of damage that can impair the availability of the internal systems within the structure has been introduced. c) The lightning ground strike-point density NSG has been introduced replacing the lightning flash density NG in the evaluation of expected average annual number of dangerous events. d) Reduction of a few risk components can be achieved by the use of preventive temporary measures activated by means of a thunderstorm warning system (TWS) compliant with IEC 62793. The risk of direct strike to people in open areas has been introduced, considering the reduction of that risk using a TWS.
- Draft123 pagesEnglish languagesale 10% offe-Library read for×1 day
- 24-Oct-2024
- 08-Sep-2019
- 29.020
- 91.120.40
- CLC/TC 81X
IEC 62561-7:2024 is available as IEC 62561-7:2024 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 62561-7:2024 specifies the requirements and tests for earthing enhancing compounds producing low resistance of an earth termination system. This third edition cancels and replaces the second edition published in 2018. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) Figure A.1 has been replaced with a simpler one that clearly shows the high and low corrosion load limits of the earth enhancing compounds without the need for special knowledge; b) pH measurement has been introduced.
- Standard22 pagesEnglish languagesale 10% offe-Library read for×1 day
- 28-Mar-2024
- 29.020
- 91.120.40
- CLC/TC 81X
IEC 62561-5:2023 is available as IEC 62561-5:2023 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 62561-5:2023 specifies the requirements and tests for earth electrode inspection housings (earth housings) installed in the earth and for earth electrode seals. Lightning protection system components (LPSC) can also be suitable for use in hazardous atmospheres. For this reason, there are additional requirements when installing the components under such conditions. This third edition cancels and replaces the second edition published in 2017. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) A classification of earth electrode seals has been added.
- Standard21 pagesEnglish languagesale 10% offe-Library read for×1 day
- 18-Jan-2024
- 29.020
- 91.120.40
- CLC/TC 81X
IEC 62561-4:2023 is available as IEC 62561-4:2023 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 62561-4:2023 deals with the requirements and tests for metallic and non-metallic conductor fasteners that are used to retain and support the air-termination, down-conductor and earth-termination systems. This third edition cancels and replaces the second edition published in 2017. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) alignment with the latest edition of ISO IEC 60068-2-52:2017 relating to salt mist atmosphere treatment; b) alignment with the new edition of ISO 22479:2019 relating to humid sulphurous atmosphere treatment; c) new normative annex for the applicability of previous tests.
- Standard26 pagesEnglish languagesale 10% offe-Library read for×1 day
- 23-Nov-2023
- 29.020
- 91.120.40
- CLC/TC 81X
This part of IEC 62561 specifies the requirements and tests for devices intended to count the number of lightning strikes based on the current flowing in a conductor. This conductor may be part of a lightning protection system (LPS) or connected to an SPD installation or other conductors, which are not intended to conduct a significant portion of lightning currents. LSCs for use in hazardous atmospheres, extra requirements for the components may be necessary to be taken. NOTE In CENELEC countries, testing requirements of components for explosive atmosphere are specified in CLC/TS 50703-2.
- Standard28 pagesEnglish languagesale 10% offe-Library read for×1 day
- 22-Jun-2023
- 29.020
- 91.120.40
- CLC/TC 81X
IEC 62561-1:2023 is available as IEC 62561-1:2023 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 62561-1:2023 specifies the requirements and tests for metallic connection components that form part of a lightning protection system (LPS). Typically, these can be connectors, clamps, bonding and bridging components, expansion pieces and test joints. This third edition cancels and replaces the second edition published in 2017. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) definitions of connection types mentioned in the scope have been added; b) location classification has been expanded in detail; c) the document has been updated in line with the new edition of ISO 22479:2019 on humid sulphurous atmosphere treatment; d) a new normative Annex E for reduced test procedures has been introduced.
- Standard32 pagesEnglish languagesale 10% offe-Library read for×1 day
- 11-May-2023
- 29.020
- 91.120.40
- CLC/TC 81X
IEC 62793:2020(E) describes the characteristics of thunderstorm warning systems (TWSs) in order to implement lightning hazard preventive measures. Single sensors and/or a network of sensors (e.g. lightning location system) can be used as a TWS. This second edition cancels and replaces the first edition, published in 2016. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: - portable devices are no longer covered by this standard; - in Clause 5, classes of TWS have been deleted; - in Clause 6, updated figures and more detailed text are provided to better illustrate the alarm timeline; - in Clause 9, the text has been summarized and refers now to the application guide given in Annex F; - annexes have been reorganized; - Annex E is normative.
- Standard46 pagesEnglish languagesale 10% offe-Library read for×1 day
- 29-Oct-2020
- 29.020
- 91.120.40
- CLC/TC 81X
IEC 62858:2019 is available as IEC 62858:2019 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition. IEC 62858:2019 introduces and discusses all necessary measures to make reliable and homogeneous the values of ground flash density, NG and ground strike point density, NSG, obtained from lightning location systems (LLSs) in various countries. Only parameters that are relevant to risk assessment are considered. This second edition cancels and replaces the first edition published in 2015. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: - Two informative annexes are introduced dealing with the determination of lightning density for risk calculation (Annex A) and ground strike point calculation methods (Annex B).
- Standard18 pagesEnglish languagesale 10% offe-Library read for×1 day
- 28-Nov-2019
- 12-Nov-2022
- 29.020
- 91.120.40
- CLC/TC 81X
Part 2 of IEC 62561 specifies the requirements and tests for:
– metallic conductors (other than "natural" conductors) that form part of the air-termination
and down-conductor systems,
– metallic earth electrodes that form part of the earth-termination system.
- Corrigendum8 pagesEnglish languagesale 10% offe-Library read for×1 day
- 19-Sep-2019
- 29.020
- 91.120.40
- CLC/TC 81X
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.