Radio-frequency connectors - Part 53: Sectional specification for RF coaxial connectors with inner diameter of outer conductor 16 mm with screw lock - Characteristic impedance 50 Ohm (Type S7-16)

IEC 61169-53:2015 is a sectional specification which provides information and rules for the preparation of detail specifications (DS) for RF coaxial connectors with threaded coupling, typically for use in 50 Ohms cable networks (Type S7-16).

Hochfrequenz-Steckverbinder - Teil 53: Rahmenspezifikation für koaxiale HF-Steckverbinder mit 16 mm Innendurchmesser des Außenleiters und Schraubverriegelung - Wellenwiderstand 50 Ohm (Typ S7-16)

Connecteurs pour fréquences radioélectriques - Partie 53: Spécification intermédiaire relative aux connecteurs coaxiaux pour fréquences radioélectriques avec diamètre intérieur des conducteurs extérieurs de 16 mm à verrouillage à vis – Impédance caractéristique 50 Ohm (Type S7-16)

L'IEC 61169-53:2015 est une spécification intermédiaire (SI), qui fournit des informations et des règles en vue de l'établissement de spécifications particulières (SP) relatives aux connecteurs coaxiaux pour fréquences radioélectriques avec couplage vissé, spécifiquement utilisés dans les réseaux câblés 50 Ohms (Type S7-16).

Radiofrekvenčni konektorji - 53. del: Področna specifikacija za RF koaksialne konektorje z notranjim premerom zunanjih vodnikov 16 mm z navojnim zaklopom - Karakteristična impedanca 50 ohm (tip S7-16) (IEC 61169-53:2015)

Ta del standarda IEC 61169, ki je področna specifikacija (SS), podaja informacije in določa pravila za pripravo podrobnih specifikacij (DS) za radiofrekvenčne koaksialne konektorje s spojko z navojem, običajno za uporabo v 50-ohmskih kabelskih omrežjih (tip S7-16).
Predpisuje prednje mere stikanja za konektorje za splošni namen tipa 2, podrobnosti o merah standardnih preskusnih konektorjev tipa 0, merjenje informacij in preskuse, izbrane iz standarda IEC 61169-1, ki veljajo za vse podrobne specifikacije v zvezi z radiofrekvenčnimi konektorji serije 4.1-9.5. Ta specifikacija določa priporočene lastnosti, ki jih je treba upoštevati pri sestavljanju podrobne specifikacije, ter zajema urnike preskusov in zahteve za pregled za ravni vrednotenja M in H.
Radiofrekvenčni koaksialni konektorji serije S7-16 z nazivno impedanco 50 ohmov so enote s spojko z navojem, ki se uporabljajo z različnimi radiofrekvenčnimi kabli in mikrotrakovi v mikrovalovnem prenosnem sistemu. Omejitev frekvenčnega območja delovanja je do 7,5 GHz.
OPOMBA: Izvirne mere so podane v metričnih merah. Vse nedimenzionirane slikovne konfiguracije so podane samo v referenčne namene.

General Information

Status
Published
Publication Date
28-Jan-2016
Withdrawal Date
28-Jan-2019
Current Stage
6060 - Document made available - Publishing
Start Date
29-Jan-2016
Completion Date
29-Jan-2016

Buy Standard

Standard
EN 61169-53:2016 - BARVE
English language
25 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)


SLOVENSKI STANDARD
01-april-2016
5DGLRIUHNYHQþQLNRQHNWRUMLGHO3RGURþQDVSHFLILNDFLMD]D5)NRDNVLDOQH
NRQHNWRUMH]QRWUDQMLPSUHPHURP]XQDQMLKYRGQLNRYPP]QDYRMQLP]DNORSRP
.DUDNWHULVWLþQDLPSHGDQFDRKP WLS6  ,(&
5DGLRIUHTXHQF\FRQQHFWRUV3DUW6HFWLRQDOVSHFLILFDWLRQIRU5)FRD[LDOFRQQHFWRUV
ZLWKLQQHUGLDPHWHURIRXWHUFRQGXFWRUPPZLWKVFUHZORFN&KDUDFWHULVWLFLPSHGDQFH
ȍ 7\SH6  ,(&
Ta slovenski standard je istoveten z: EN 61169-53:2016
ICS:
33.120.30 5DGLRIUHNYHQþQLNRQHNWRUML RF connectors
5)
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

EUROPEAN STANDARD EN 61169-53

NORME EUROPÉENNE
EUROPÄISCHE NORM
January 2016
ICS 33.120.30
English Version
Radio-frequency connectors - Part 53: Sectional specification for
RF coaxial connectors with inner diameter of outer conductor 16
mm with screw lock - Characteristic impedance 50 Ohm
(Type S7-16)
(IEC 61169-53:2015)
Connecteurs pour fréquences radioélectriques - Partie 53: Hochfrequenz-Steckverbinder - Teil 53:
Spécification intermédiaire relative aux connecteurs Rahmenspezifikation für koaxiale HF-Steckverbinder mit 16
coaxiaux pour fréquences radioélectriques avec diamètre mm Innendurchmesser des Außenleiters und
intérieur des conducteurs extérieurs de 16 mm à Schraubverriegelung - Wellenwiderstand 50 Ohm (Typ S7-
verrouillage à vis - Impédance caractéristique 50 Ohm 16)
(Type S7-16) (IEC 61169-53:2015)
(IEC 61169-53:2015)
This European Standard was approved by CENELEC on 2015-10-21. CENELEC members are bound to comply with the CEN/CENELEC
Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC
Management Centre or to any CENELEC member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation
under the responsibility of a CENELEC member into its own language and notified to the CEN-CENELEC Management Centre has the
same status as the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic,
Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia,
Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland,
Turkey and the United Kingdom.

European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels
© 2016 CENELEC All rights of exploitation in any form and by any means reserved worldwide for CENELEC Members.
Ref. No. EN 61169-53:2016 E
European foreword
The text of document 46F/309/CDV, future edition 1 of IEC 61169-53, prepared by SC 46F "R.F. and
microwave passive components" of IEC/TC 46 "Cables, wires, waveguides, R.F. connectors, R.F. and
microwave passive components and accessories" was submitted to the IEC-CENELEC parallel vote
and approved by CENELEC as EN 61169-53:2016.

The following dates are fixed:
• latest date by which the document has to be (dop) 2016-07-29
implemented at national level by
publication of an identical national
standard or by endorsement
(dow) 2019-01-29
• latest date by which the national
standards conflicting with the
document have to be withdrawn
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. CENELEC [and/or CEN] shall not be held responsible for identifying any or all such
patent rights.
Endorsement notice
The text of the International Standard IEC 61169-53:2015 was approved by CENELEC as a European
Standard without any modification.
Annex ZA
(normative)
Normative references to international publications
with their corresponding European publications
The following documents, in whole or in part, are normatively referenced in this document and are
indispensable for its application. For dated references, only the edition cited applies. For undated
references, the latest edition of the referenced document (including any amendments) applies.
NOTE 1 When an International Publication has been modified by common modifications, indicated by (mod), the relevant

EN/HD applies.
NOTE 2 Up-to-date information on the latest versions of the European Standards listed in this annex is available here:
www.cenelec.eu.
Publication Year Title EN/HD Year
IEC 61169-1 2013 Radio-frequency connectors -- Part 1: EN 61169-1 2013
Generic specification - General
requirements and measuring methods
IEC 62037 series Passive RF and microwave devices, EN 62037 series
intermodulation level measurement

IEC 61169-53 ®
Edition 1.0 2015-09
INTERNATIONAL
STANDARD
NORME
INTERNATIONALE
colour
inside
Radio-frequency connectors –
Part 53: Sectional specification for RF coaxial connectors with inner diameter of

outer conductor 16 mm with screw lock – Characteristic impedance 50 Ω (Type

S7-16)
Connecteurs pour fréquences radioélectriques –

Partie 53: Spécification intermédiaire relative aux connecteurs coaxiaux pour

fréquences radioélectriques avec diamètre intérieur des conducteurs extérieurs

de 16 mm à verrouillage à vis – Impédance caractéristique 50 Ω (Type S7-16)

INTERNATIONAL
ELECTROTECHNICAL
COMMISSION
COMMISSION
ELECTROTECHNIQUE
INTERNATIONALE
ICS 33.120.30 ISBN 978-2-8322-2878-4

– 2 – IEC 61169-53:2015 © IEC 2015
CONTENTS
FOREWORD . 4
1 Scope . 6
2 Normative references . 6
3 Mating face and gauge information . 6
3.1 Dimensions – General connectors – Grade 2 . 6
3.1.1 Connector with pin-centre contact . 6
3.1.2 Connector with socket centre contact . 7
3.2 Gauges . 8
3.2.1 Gauge pin for socket-centre contact . 8
3.2.2 Test procedure . 9
3.3 Dimensions – Standard test connectors – Grade 0 . 9
3.3.1 Connector with pin-centre contact . 9
3.3.2 Standard test connector with socket-centre contact . 10
4 Quality assessment procedures . 12
4.1 General . 12
4.2 Ratings and characteristics (see Clause 5 of IEC 61169-1:2013) . 12
4.3 Test schedule and inspection requirements. 14
4.3.1 Acceptance tests . 14
4.3.2 Periodic tests . 14
4.4 Procedures for the quality conformance . 15
4.4.1 Quality conformance inspection . 15
4.4.2 Qualification approval and its maintenance . 16
5 Instructions for preparation of detail specifications . 16
5.1 General . 16
5.2 Identification of the component . 16
5.3 Performances . 16
5.4 Marking, ordering information and related matters . 16
5.5 Selection of tests, test conditions and severities . 16
5.6 Blank detail specification pro-forma for type S7-16 connector . 17
6 Marking . 21
6.1 Marking of component . 21
6.2 Marking and contents of package . 21

Figure 1 – Connector with pin-centre contact (for dimensions, see Table 1) . 7
Figure 2 – Connector with socket-centre contact (for dimensions, see Table 2). 8
Figure 3 – Gauge pin for socket-centre contact (for dimensions, see Table 3) . 9
Figure 4 – Connector with pin-centre contact (for dimensions, see Table 4) . 10
Figure 5 – Connector with socket-centre contact (for dimensions, see Table 5). 11

Table 1 – Dimensions of connector with pin-centre contact . 7
Table 2 – Dimensions of connector with socket centre contact . 8
Table 3 – Dimensions of gauge pin for socket-centre contact . 9
Table 4 – Dimensions of connector with pin-centre contact . 10
Table 5 – Dimensions of connector with socket-centre contact . 11

IEC 61169-53:2015 © IEC 2015 – 3 –
Table 6 – Rating and characteristics . 12
Table 7 – Acceptance tests . 14
Table 8 – Periodic tests . 15

– 4 – IEC 61169-53:2015 © IEC 2015
INTERNATIONAL ELECTROTECHNICAL COMMISSION
____________
RADIO-FREQUENCY CONNECTORS –
Part 53: Sectional specification for RF coaxial connectors
with inner diameter of outer conductor 16 mm with screw lock –
Characteristic impedance 50 Ω (Type S7-16)

FOREWORD
1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of IEC is to promote
international co-operation on all questions concerning standardization in the electrical and electronic fields. To
this end and in addition to other activities, IEC publishes International Standards, Technical Specifications,
Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC
Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested
in the subject dealt with may participate in this preparatory work. International, governmental and non-
governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely
with the International Organization for Standardization (ISO) in accordance with conditions determined by
agreement between the two organizations.
2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international
consensus of opinion on the relevant subjects since each technical committee has representation from all
interested IEC National Committees.
3) IEC Publications have the form of recommendations for international use and are accepted by IEC National
Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC
Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any
misinterpretation by any end user.
4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications
transparently to the maximum extent possible in their national and regional publications. Any divergence
between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in
the latter.
5) IEC itself does not provide any attestation of conformity. Independent certification bodies provide conformity
assessment services and, in some areas, access to IEC marks of conformity. IEC is not responsible for any
servi
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.