EN 60335-2-27:2003/A1:2008
(Amendment)Household and similar electrical appliances - Safety - Part 2-27: Particular requirements for appliances for skin exposure to ultraviolet and infrared radiation
Household and similar electrical appliances - Safety - Part 2-27: Particular requirements for appliances for skin exposure to ultraviolet and infrared radiation
Superseded by EN 60335-2-27:2010
Sicherheit elektrischer Geräte für den Hausgebrauch und ähnliche Zwecke - Teil 2-27: Besondere Anforderungen für Hautbestrahlungsgeräte mit Ultraviolett- und Infrarotstrahlung
Appareils électrodomestiques et analogues - Sécurité - Partie 2-27: Règles particulières pour les appareils d'exposition de la peau aux rayonnements ultraviolets et infrarouges
Gospodinjski in podobni električni aparati - Varnost - 2-27. del: Posebne zahteve za aparate za nego kože z ultravijoličnim in infrardečim sevanjem (IEC 60335-2-27:2002/A1:2004, spremenjen)
General Information
Relations
Standards Content (Sample)
SLOVENSKI STANDARD
01-januar-2009
*RVSRGLQMVNLLQSRGREQLHOHNWULþQLDSDUDWL9DUQRVWGHO3RVHEQH]DKWHYH
]DDSDUDWH]DQHJRNRåH]XOWUDYLMROLþQLPLQLQIUDUGHþLPVHYDQMHP,(&
$VSUHPHQMHQ
Household and similar electrical appliances - Safety -- Part 2-27: Particular requirements
for appliances for skin exposure to ultraviolet and infrared radiation
Sicherheit elektrischer Geräte für den Hausgebrauch und ähnliche Zwecke -- Teil 2-27:
Besondere Anforderungen für Hautbestrahlungsgeräte mit Ultraviolett- und
Infrarotstrahlung
Appareils électrodomestiques et analogues - Sécurité -- Partie 2-27: Règles particulières
pour les appareils d'exposition de la peau aux rayonnements ultraviolets et infrarouges
Ta slovenski standard je istoveten z: EN 60335-2-27:2003/A1:2008
ICS:
13.120 Varnost na domu Domestic safety
97.170 Oprema za nego telesa Body care equipment
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
EUROPEAN STANDARD
EN 60335-2-27/A1
NORME EUROPÉENNE
October 2008
EUROPÄISCHE NORM
ICS 13.120; 97.170
English version
Household and similar electrical appliances -
Safety -
Part 2-27: Particular requirements for appliances
for skin exposure to ultraviolet and infrared radiation
(IEC 60335-2-27:2002/A1:2004, modified)
Appareils électrodomestiques Sicherheit elektrischer Geräte
et analogues - für den Hausgebrauch
Sécurité - und ähnliche Zwecke -
Partie 2-27: Règles particulières Teil 2-27: Besondere Anforderungen
pour les appareils d'exposition für Hautbestrahlungsgeräte
de la peau aux rayonnements mit Ultraviolett- und Infrarotstrahlung
ultraviolets et infrarouges (IEC 60335-2-27:2002/A1:2004,
(CEI 60335-2-27:2002/A1:2004, modifié) modifiziert)
This amendment A1 modifies the European Standard EN 60335-2-27:2003; it was approved by CENELEC on
2008-10-01. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which
stipulate the conditions for giving this amendment the status of a national standard without any alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on
application to the Central Secretariat or to any CENELEC member.
This amendment exists in three official versions (English, French, German). A version in any other language
made by translation under the responsibility of a CENELEC member into its own language and notified to the
Central Secretariat has the same status as the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Cyprus, the
Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia,
Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain,
Sweden, Switzerland and the United Kingdom.
CENELEC
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
Central Secretariat: rue de Stassart 35, B - 1050 Brussels
© 2008 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.
Ref. No. EN 60335-2-27:2003/A1:2008 E
Foreword
At the Milan meeting of CENELEC TC 61 in November 2004, it was decided to submit
amendment 1:2004 to IEC 60335-2-27:2002, prepared by the IEC Technical Committee 61, to the
Unique Acceptance Procedure.
A proposal to amend EN 60335-2-27:2003, document CLC/TC 61(SEC)1482, was discussed during
the Balsthal meeting of CENELEC TC 61 in June 2004, when it was decided to submit a draft for an
amendment to the Unique Acceptance Procedure.
Although both drafts (prA1 & prAA) received sufficient support, CENELEC TC 61 set up an ad hoc WG
for adapting the standard to Mandate M/397 received from the European Commission. This ad hoc
WG prepared a draft, document CLC/TC 61(SEC)1598, that was discussed during the Málaga meeting
of CENELEC TC 61 in June 2007, when it was decided to submit a draft to the formal vote.
The draft was circulated in October 2007 and was approved by CENELEC as amendment A1 to
EN 60335-2-27:2003 on 2008-10-01.
The following dates are applicable:
– latest date by which the EN has to be implemented
at national level by publication of an identical
national standard or by endorsement (dop) 2009-04-01
– date on which the national standards conflicting
with the amendment have to be withdrawn (dow) 2009-04-01
Compliance with the provisions of this amendment ensures that the concerns expressed in
1)
Commission Opinion 2004/C275/03 are met.
There are no special national conditions causing a deviation from this amendment.
There are no national deviations from this amendment, other than those listed in Annex ZB to
EN 60335-2-27:2003.
p NOTE In this document, p is used in the margin to indicate instructions for preparing the printed version.
__________
1)
Commission Opinion of 27 October 2004 within the framework of Council Directive 73/23/EEC relating to electrical
equipment designed for use within certain voltage limits — Safety of tanning devices for cosmetic purposes, Official
Journal C 275 , 10/11/2004 P. 0003 – 0005.
– 3 – EN 60335-2-27:2003/A1:2008
Endorsement notice
The text of amendment 1:2004 to the International Standard IEC 60035-2-27:2002 was approved by
CENELEC as an amendment to the European Standard with agreed common modifications as given
below.
COMMON MODIFICATIONS
Contents
p For Annex BB, replace "(informative)" by "(normative)".
Introduction
Add after the second paragraph:
This standard covers appliances used for intentional tanning. Irradiance limit values are not to be
used as safety guidelines for non-intentional UV-exposure.
3 Definitions
Add the following new definition:
3.Z101
minimal erythemal dose (MED)
the minimal amount of UV radiation exposure required to cause perceptible reddening of the skin
6 Classification
p Ignore the replacement of Subclause 6.101.
7 Marking and instructions
p 7.1 Ignore the replacement of the first paragraph, including Note 101.
p Ignore the deletion of the fourth paragraph.
p 7.6 Ignore the addition of Subclause 7.6.
p 7.12 Replace all of the instructions in IEC 60335-2-27/A1 regarding this subclause by:
Replace the first dashed item by the following:
— a statement that UV appliances are not to be used by:
• persons under the age of 18 years,
• persons suffering from sunburn,
• persons not able to tan at all or not able to tan without burning when exposed to the sun,
• persons who burn easily when exposed to the sun,
• persons who tend to freckle,
• persons having more than 20 moles of any size on the body,
• persons having atypical moles (atypical moles are defined as asymmetrical moles larger
than 5 mm in diameter with variable pigmentation and irregular borders; in case of
doubt, seek medical advice),
• persons suffering from or previously suffering from skin cancer or predisposed to skin
cancer,
• persons with a family history of melanoma;
Add the following new items after the first dashed item:
– a statement that exposures should not exceed a person's minimal erythemal dose (MED).
If erythema (skin reddening) appears hours after any exposure, further exposure should
cease. After one week, exposures could be restarted from the beginning of the schedule of
exposure;
– a statement that UV appliances are not to be used without taking medical advice if
unexpected effects, such as itching, occur within 48 h of the first session.
Replace Note 101 by the following:
NOTE 101 The recommended exposure time for the first-test session for untanned skin is to correspond to a dose not
exceeding 100 J/m², weighted according to the erythema action spectrum shown in Figure 101, or as a result of a test
on a small area of the skin. Otherwise sunbed exposure should be at least 10 min.
Replace Note 102 by the following:
NOTE 102 As any exposure to UV radiation increases the risk of skin cancer, there is no safe value of maximum
yearly dose, but it is recommended not to exceed 25 kJ/m , weighted according to the non-melanoma skin cancer
action spectrum shown in Figure 101 and taking into account the recommended schedule of exposure.
p 7.14 Ignore the addition of Subclause 7.14.
32 Radiation, toxicity and similar hazards
p 32.101 Replace the first paragraph of the replacement by the following:
Appliances shall not present a toxic or similar hazard. Appliances having UV emitters shall not
emit radiation having a total effective irradiance exceeding 0,3 W/m weighted according to the
erythema action spectrum of Figure 101.
Appliances shall comply with the values specified in Table BB.1.
p Replace all paragraphs between Note 3 and Note 4 by the following:
Appliances shall have a total irradiance not exceeding 0,003 W/m for wavelengths between
200 nm and 280 nm and measured by a spectroradiometer between 250 nm and 280 nm.
Annex BB
p Replace "informative" by "normative".
p Delete definition BB.1.5.
– 5 – EN 60335-2-27:2003/A1:2008
BB.2 Classification
p Delete the fifth dash.
p In the Note, replace ", UV type 4 appliances and UV type 5 appliances" by "and UV type 4
appliances".
BB.3 Effective irradiance
p Replace the text and Table BB.1 by:
The effective irradiance for each type of UV appliance, weighted according to the erythema
action spectrum of Figure 101, is given in Table BB.1.
Table BB.1 – Limits of effective irradiance
UV type appliance Effective irradiance
W/m
250 nm < λ ≤ 320 nm 320 nm < λ < 400 nm
1 < 0,000 5 ≥ 0,15
2 0,000 5 to 0,15 ≥ 0,15
3 < 0,15 < 0,15
4 ≥ 0,15 < 0,15
λ is the wavelength of the radiation
Bibliography
p Ignore the replacement of the existing text.
NORME CEI
INTERNATIONALE IEC
60335-2-27
INTERNATIONAL
STANDARD
AMENDEMENT 1
AMENDMENT 1
2004-07
Amendement 1
Appareils électrodomestiques et analogues –
Sécurité –
Partie 2-27:
Règles particulières pour les appareils
d'exposition de la peau aux rayonnements
ultraviolets et infrarouges
Amendment 1
Household and similar electrical appliances –
Safety –
Part 2-27:
Particular requirements for appliances
for skin exposure to ultraviolet and
infrared radiation
” IEC 2004 Droits de reproduction réservés Copyright - all rights reserved
International Electrotechnical Commission, 3, rue de Varembé, PO Box 131, CH-1211 Geneva 20, Switzerland
Telephone: +41 22 919 02 11 Telefax: +41 22 919 03 00 E-mail: inmail@iec.ch Web: www.iec.ch
CODE PRIX
Commission Electrotechnique Internationale K
PRICE CODE
International Electrotechnical Commission
ɆɟɠɞɭɧɚɪɨɞɧɚɹɗɥɟɤɬɪɨɬɟɯɧɢɱɟɫɤɚɹɄɨɦɢɫɫɢɹ
Pour prix, voir catalogue en vigueur
For price, see current catalogue
60335-2-27 Amend. 1 ” IEC:2004 – 3 –
FOREWORD
This amendment has been prepared by IEC technical committee 61: Safety of household and
similar electrical appliances.
The text of this amendment is based on the following documents:
FDIS Report on voting
61/2688/FDIS 61/2720/RVD
Full information on the voting for the approval of this amendment can be found in the report
on voting indicated in the above table.
The committee has decided that the contents of this amendment and the base publication will
remain unchanged until the maintenance result date indicated on the IEC web site under
"http://webstore.iec.ch" in the data related to the specific publication. At this date, the
publication will be
reconfirmed,
withdrawn,
replaced by a revised edition, or
amended.
___________
CONTENTS
Add the title of Annex BB as follows:
Annex BB (informative) Detailed classification of UV appliances
Replace the existing title of Figure 101 by “UV action spectrums”.
Delete the reference to Table 101.
Renumber Table 102 as Table 101.
INTRODUCTION
Replace the second sentence of the second paragraph by the following:
It also covers abnormal situations that can be expected in practice and takes into account the
way in which electromagnetic phenomena can affect the safe operation of appliances.
3 Definitions
Delete the following definitions:
3.102, 3.103, 3.104 and 3.105
Renumber definitions “3.106” and “3.107” as “3.102” and 3.103” respectively.
60335-2-27 Amend. 1 ” IEC:2004 – 5 –
6 Classification
6.101 Replace the existing text by the following:
UV appliances shall be one of the following types with respect to the emission of ultraviolet
radiation:
– appliances for household use;
– appliances for commercial use only.
NOTE 1 Appliances for household use may also be for commercial use, such as in tanning salons, beauty
parlours and similar premises.
NOTE 2 Detailed classification of the appliances is described in Annex BB.
Compliance is checked by inspection and by the relevant tests.
7 Marking and instructions
7.1 Replace the first paragraph, including Note 101, by the following:
UV appliances intended for use in tanning salons, beauty parlours and similar premises shall
be marked with the “not for household use” symbol shown in 7.6 or with the substance of the
following:
Not for household use
Delete the fourth paragraph.
Add the following subclause:
7.6 Addition:
Not for household use
NOTE 101 This symbol incorporates the prohibition sign of ISO 3864
7.12 Add the following new item after the first dashed item:
– a statement that UV appliances are not to be used without taking medical advice if
unexpected effects, such as itching, occur within 48 hours of the first session;
Replace note 101 by the following:
NOTE 101 The recommended exposure time for the first session for untanned skin is to correspond to a dose not
exceeding 100 J/m , weighted according to the erythema
...
Questions, Comments and Discussion