Electromagnetic compatibility - Electrical apparatus for the detection and measurement of combustible gases, toxic gases or oxygen

This document specifies requirements for the electromagnetic compatibility (EMC) for electrical apparatus for the detection and measurement of combustible gases, toxic gases or oxygen which are subject to the performance standards for gas detection apparatus, for example EN 45544 (all parts), EN 50104, EN 50194 (all parts), EN 50291 (all parts), EN 50379 (all parts), EN 50543, EN 50545 1, EN 60079 29 1 or EN 60079 29 4. NOTE For the purpose of this standard, the word ‘toxic’ covers ‘very toxic’, ‘toxic’, ‘harmful’, ‘corrosive‘, ‘irritating‘, ‘sensitizing‘, ‘carcinogenic‘, ‘mutagenic‘ and ‘teratogenic‘. This document applies to apparatus intended for use in residential, commercial and light-industrial environments as well as to apparatus intended for use in industrial environments, and includes AC-, DC- or battery powered apparatus. This document is also applicable to apparatus which is intended for use in hazardous areas which could contain explosive or potentially explosive atmospheres. It covers only normal operation and does not cover safety requirements related to EMC phenomena. This document is a product standard which is based on the product family standard EN 61326 1. prEN 50270:2019 takes precedence over the product family standard and over generic standards. This document applies to electrical apparatus for the detection and measurement of combustible gases, toxic gases or oxygen that include functions specified by the manufacturer as being safety functions and can include functions specified as not being safety functions. All performance standards for the detection and measurement of combustible gases, toxic gases or oxygen include the minimum requirements for functional safety specified in EN 50271. There are also gas detectors and gas detection systems which are intended to be used with safety integrity levels SIL 1 to SIL 3 according to EN 50402 and EN 61508 (all parts). For functional safety in industrial applications, this document has taken into account those aspects of EN 61326 3 2 relating to the measuring and warning function of the apparatus defined as safety function. This standard specifies requirements for immunity tests in relation to continuous and transient, conducted and radiated disturbances, including electrostatic discharges, and also for emission tests. The test requirements are specified for each port considered. Apparatus falling within the scope of this document are classified as follows by the following types. — Type 1: apparatus intended for use in residential, commercial and light-industrial environments, as described in EN 61000 6 1 and EN 61000 6 3. — Type 2: apparatus intended for use in industrial environments, as described in EN 61000 6 2 and EN 61000 6 4. Type 1 apparatus for which the manufacturer claims a safety integrity level should be considered as type 2 apparatus with regard to immunity requirements. This document does not apply to any of the following: — apparatus intended for the detection of dusts or mists in air; — scientific or laboratory based apparatus used only for analysis or measurement; — apparatus used exclusively for process measurement purposes; — apparatus for medical purposes; — apparatus used for breath alcohol measurement — apparatus intended for the direct measurement of automotive exhaust gases.

Elektromagnetische Verträglichkeit – Elektrische Geräte für die Detektion und Messung von brennbaren Gasen, toxischen Gasen oder Sauerstoff

Compatibilité électromagnétique – Appareils de détection et de mesure de gaz combustible, de gaz toxique et d’oxygène

Elektromagnetna združljivost - Električne naprave za odkrivanje in merjenje vnetljivih in strupenih plinov ali kisika

General Information

Status
Not Published
Publication Date
02-May-2021
Withdrawal Date
26-Sep-2021
Current Stage
4060 - Enquiry results established and sent to TC, SR, BTTF - Enquiry
Start Date
20-Dec-2019
Due Date
30-Jan-2020
Completion Date
20-Dec-2019

Relations

Buy Standard

Draft
prEN 50270:2019
English language
20 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)


SLOVENSKI STANDARD
01-december-2019
Elektromagnetna združljivost - Električne naprave za odkrivanje in merjenje
vnetljivih in strupenih plinov ali kisika
Electromagnetic compatibility - Electrical apparatus for the detection and measurement
of combustible gases, toxic gases or oxygen
Elektromagnetische Verträglichkeit – Elektrische Geräte für die Detektion und Messung
von brennbaren Gasen, toxischen Gasen oder Sauerstoff
Compatibilité électromagnétique – Appareils de détection et de mesure de gaz
combustible, de gaz toxique et d’oxygène
Ta slovenski standard je istoveten z: prEN 50270
ICS:
13.230 Varstvo pred eksplozijo Explosion protection
13.320 Alarmni in opozorilni sistemi Alarm and warning systems
33.100.01 Elektromagnetna združljivost Electromagnetic compatibility
na splošno in general
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

EUROPEAN STANDARD DRAFT
prEN 50270
NORME EUROPÉENNE
EUROPÄISCHE NORM
September 2019
ICS 13.320 Will supersede EN 50270:2015 and all of its
amendments and corrigenda (if any)
English Version
Electromagnetic compatibility - Electrical apparatus for the
detection and measurement of combustible gases, toxic gases
or oxygen
Compatibilité électromagnétique - Appareils de détection et Elektromagnetische Verträglichkeit - Elektrische Geräte für
de mesure de gaz combustible, de gaz toxique et die Detektion und Messung von brennbaren Gasen,
d'oxygène toxischen Gasen oder Sauerstoff
This draft European Standard is submitted to CENELEC members for enquiry.
Deadline for CENELEC: 2019-12-20.

It has been drawn up by CLC/TC 31.

If this draft becomes a European Standard, CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which
stipulate the conditions for giving this European Standard the status of a national standard without any alteration.

This draft European Standard was established by CENELEC in three official versions (English, French, German).
A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to
the CEN-CENELEC Management Centre has the same status as the official versions.

CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic,
Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the
Netherlands, Norway, Poland, Portugal, Republic of North Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland,
Turkey and the United Kingdom.

Recipients of this draft are invited to submit, with their comments, notification of any relevant patent rights of which they are aware and to
provide supporting documentation.

Warning : This document is not a European Standard. It is distributed for review and comments. It is subject to change without notice and
shall not be referred to as a European Standard.

European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
CEN-CENELEC Management Centre: Rue de la Science 23, B-1040 Brussels
© 2019 CENELEC All rights of exploitation in any form and by any means reserved worldwide for CENELEC Members.
Project: 67360 Ref. No. prEN 50270 E

prEN 50270:2019 (E)
Contents
European foreword 3
1 Scope 4
2 Normative references 5
3 Terms and Definitions 6
4 EMC test plan 8
4.1 General.8
4.2 Configuration of the apparatus (EUT) during testing.8
4.2.1 General .8
4.2.2 Composition of EUT .9
4.2.3 Configuration of EUT, operation modes .9
4.2.4 I/O ports .9
4.2.5 Auxiliary equipment .9
4.2.6 Cabling and earthing (grounding) .9
4.3 Operation conditions of EUT during testing .9
4.3.1 Test gases, alarm settings .9
4.3.2 Environmental conditions .10
4.3.3 EUT software during test .10
4.4 Test description .10
5 Immunity tests 10
5.1 Performance criteria .10
5.2 Requirements .11
6 Emission tests 11
7 Test report 12
8 Modifications 12
Annex ZA (informative) Relationship between this European standard and the essential requirements of
Directive 2014/30/EU [2014 OJ L96] aimed to be covered 18
Bibliography 19
prEN 50270:2019 (E)
European foreword
This document (prEN 50270:2019) has been prepared by CLC/SC 31-9 “Electrical apparatus for the
detection and measurement of combustible gases to be used in industrial and commercial potentially
explosive atmospheres” of CLC/TC 31, “Electrical apparatus for explosive atmospheres”.
This document is currently submitted to the Enquiry/ Primary Questionnaire.
The following dates are proposed:
• latest date by which the existence of this (doa) dor + 6 months
document has to be announced at national
level
• latest date by which this document has to be (dop) dor + 12 months
implemented at national level by publication of
an identical national standard or by
endorsement
• latest date by which the national standards
(dow) dor + 36 months
conflicting with this document have to be (to be confirmed or
withdrawn modified when voting)
This document will supersede EN 50270:2015 and all of its amendments and corrigenda (if any).
EN 50270:2018 includes no significant technical changes with respect to EN 50270:2015 + AC/2016.
This document has been prepared under the European Commission standardization request M/552 given
to CENELEC by the European Commission and the European Free Trade Association, and supports
essential requirements of EU Directive 2014/30/EU.
For the relationship with EU Directive 2014/30/EU see informative Annex ZZ, which is an integral part of
this document.
CLC/TC 216 “Gas detectors” contributed to the preparation of the text.
prEN 50270:2019 (E)
1 Scope
This document specifies requirements for the electromagnetic compatibility (EMC) for electrical apparatus
for the detection and measurement of combustible gases, toxic gases or oxygen which are subject to the
performance standards for gas detection apparatus, for example EN 45544 (all parts), EN 50104,
EN 50194 (all parts), EN 50291 (all parts), EN 50379 (all parts), EN 50543, EN 50545-1, EN 60079-29-1
or EN 60079-29-4.
NOTE For the purpose of this standard, the word ‘toxic’ covers ‘very toxic’, ‘toxic’, ‘harmful’, ‘corrosive‘,
‘irritating‘, ‘sensitizing‘, ‘carcinogenic‘, ‘mutagenic‘ and ‘teratogenic‘.
This document applies to apparatus intended for use in residential, commercial and light-industrial
environments as well as to apparatus intended for use in industrial environments, and includes AC-, DC-
or battery powered apparatus.
This document is also applicable to apparatus which is intended for use in hazardous areas which could
contain explosive or potentially explosive atmospheres. It covers only normal operation and does not
cover safety requirements related to EMC phenomena.
This document is a product standard which is based on the product family standard EN 61326-1.
prEN 50270:2019 takes precedence over the product family standard and over generic standards.
This document applies to electrical apparatus for the detection and measurement of combustible gases,
toxic gases or oxygen that include functions specified by the manufacturer as being safety functions and
can include functions specified as not being safety functions.
All performance standards for the detection and measurement of combustible gases, toxic gases or
oxygen include the minimum requirements for functional safety specified in EN 50271. There are also gas
detectors and gas detection systems which are intended to be used with safety integrity levels SIL 1 to
SIL 3 according to EN 50402 and EN 61508 (all parts). For functional safety in industrial applications, this
document has taken into account those aspects of EN 61326-3-2 relating to the measuring and warning
function of the apparatus defined as safety function.
This standard specifies requirements for immunity tests in relation to continuous and transient, conducted
and radiated disturbances, including electrostatic discharges, and also for emission tests. The test
requirements are specified for each port considered.
Apparatus falling within the scope of this document are classified as follows by the following types.
— Type 1: apparatus intended for use in residential, commercial and light-industrial environments, as
described in EN 61000-6-1 and EN 61000-6-3.
— Type 2: apparatus intended for use in industrial environments, as described in EN 61000-6-2 and
EN 61000-6-4.
Type 1 apparatus for which the manufacturer claims a safety integrity level should be considered as type 2
apparatus with regard to immunity requirements.
This document does not apply to any of the following:
— apparatus intended for the detection of dusts or mists in air;
— scientific or laboratory based apparatus used only for analysis or measurement;
— apparatus used exclusively for process measurement purposes;
— apparatus for medical purposes;
— apparatus used for breath alcohol measurement
— apparatus intended for the direct measurement of automotive exhaust gases.
prEN 50270:2019 (E)
2 Normative references
The following documents are referred to in the text in such a way that some or all of their content
constitutes requirements of this document. For dated references, only the edition cited applies. For
undated references, the latest edition of the referenced document (including any amendments) applies.
EN 50291-1:2018, Gas detectors — Electrical apparatus for the detection of carbon monoxide in domestic
premises — Part 1: Test methods and performance requirements
EN 50291-2:2010, Electrical apparatus for the detection of carbon monoxide in domestic premises — Part
2: Electrical apparatus for continuous operation in a fixed installation in recreational vehicles and similar
premises including recreational craft — Additional test methods and performance requirements
EN 50545-1:2011, Electrical apparatus for the detection and measurement of toxic and combustible
gases in car parks and tunnels — Part 1: General performance requirements and test methods for the
detection and measurement of carbon monoxide and nitrogen oxides
EN 61000-4-2:2009, Electromagnetic compatibility (EMC) — Part 4-2: Testing and measurement
techniques — Electrostatic discharge immunity test (IEC 61000-4-2:2008)
EN 61000-4-3:2006, Electromagnetic compatibility (EMC) — Part 4-3: Testing and measurement
techniques — Radiated, radio-frequency, electromagnetic field immunity test (IEC 61000-4-3:2006)
EN 61000-4-4:2012, Electromagnetic compatibility (EMC) — Part 4-4: Testing and measurement
techniques — Electrical fast transient/burst immunity test (IEC 61000-4-4:2012)
EN 61000-4-5:2006, Electromagnetic compatibility (EMC) — Part 4-5: Testing and measurement
techniques — Surge immunity test (IEC 61000-4-5:2005)
EN 61000-4-6:2014, Electromagnetic compatibility (EMC) — Part 4-6: Testing and measurement
techniques — Immunity to conducted disturbances, induced by radio-frequency fields
(IEC 61000-4-6:2013)
EN 61000-4-8:2010, Electromagnetic compatibility (EMC) — Part 4-8: Testing and measurement
techniques — Power frequency magnetic field immunity test (IEC 61000-4-8:2009)
EN 61000-4-11:2004, Electromagnetic compatibility (EMC) — Part 4-11: Testing and measurement
techniques — Voltage dips, short interruptions and voltage variations immunity tests
(IEC 61000-4-11:2004)
EN 61000-4-29:2000, Electromagnetic compatibility (EMC) — Part 4-29: Testing and measurement
techniques — Voltage dips, short interruptions and voltage variations on d.c. input power port immunity
tests (IEC 61000-4-29:2000)
EN 61000-6-1:2007, Electromagnetic compatibility (EMC) — Part 6-1: Generic standards — Immunity for
residential, commercial and light-industrial environments (IEC 61000-6-1:2005)
EN 61000-6-2:2005, Electromagnetic compatibility (EMC) — Part 6-2: Generic standards — Immunity for
industrial environments (IEC 61000-6-2:2005)

As impacted by EN 50545-1:2011/A1:2016.
As impacted by EN 61000-4-3:2006/A1:2008 and EN 61000-4-3:2006/A2:2010.
As impacted by EN 61000-6-2:2005/AC:2005.
prEN 50270:2019 (E)
EN 61000-6-3:2007, Electromagnetic compatibility (EMC) — Part 6-3: Generic standards — Emission
standard for residential, commercial and light-industrial environments (IEC 61000-6-3:2006)
EN 61000-6-4:2007, Electromagnetic compatibility (EMC) — Part 6-4: Generic standards — Emission
standa
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.