IEC 62917:2016 specifies the characteristics of copper and copper alloy grooved contact wires of cross-sections from 70 mm2 to 170 mm2 for use on overhead contact lines. It establishes the product characteristics, the test methods, checking procedures to be used with the contact wires, together with the ordering and delivery condition.

Status
Published
Publication Date
04-Oct-2016
Drafting Committee
PT 62917 - TC 9/PT 62917
Current Stage
PPUB - Publication issued
Start Date
05-Oct-2016
Completion Date
31-Oct-2016

Buy Documents

Standard

IEC 62917:2016 - Railway applications - Fixed installations - Electric traction - Copper and copper alloy grooved contact wires Released:10/5/2016

ISBN:978-2-8322-3625-3
English and French language (97 pages)
sale 15% off
Preview
sale 15% off
Preview

Overview

IEC 62917:2016 is an international standard developed by the International Electrotechnical Commission (IEC) specifically for railway applications. It defines the characteristics and requirements for copper and copper alloy grooved contact wires utilized in fixed installations for electric traction systems. Covering cross-sectional areas from 70 mm² to 170 mm², the standard provides a comprehensive framework that outlines product specifications, material compositions, testing methods, verification procedures, and delivery conditions. This ensures consistent quality, reliability, and performance of overhead contact lines in railway electrification systems.

Key Topics

  • Material Specifications
    The standard specifies the materials used in grooved contact wires, including various grades of copper and copper alloys such as:

    • Normal and high strength copper (Cu-ETP, Cu-FRHC, Cu-HCP, Cu-OF)
    • Copper-silver alloys (CuAg 0.1)
    • Copper-cadmium alloys (CuCd 0.7, CuCd 1.0)
    • Copper-magnesium alloys (CuMg 0.2, CuMg 0.5)
    • Copper-tin alloys (CuSn 0.2)
      These materials are selected for their electrical conductivity, mechanical strength, and durability in overhead contact line environments.
  • Contact Wire Design and Dimensions
    Specific parameters for cross-sectional areas, profiles, and groove configurations are standardized for compatibility and performance. Identification grooves enable easy material recognition and quality assurance. The document includes standardized profiles such as shapes AC, BC, and BF to guide manufacturing and installation.

  • Electrical and Mechanical Properties
    IEC 62917 details electrical resistivity limits, resistance per kilometer, tensile strength, elongation after fracture, and mechanical tests like reverse bend, torsional strength, and winding property tests. These properties are critical for the reliable transmission of electrical power and mechanical endurance against wear and environmental conditions.

  • Testing and Verification
    The standard mandates rigorous testing procedures to verify material composition, physical conditions, electrical and mechanical characteristics, and jointing integrity. It sets out test types including breaking load tests, electrical resistance measurements, and microwaves assessment along the wire’s axis for quality control.

  • Ordering, Delivery, and Compliance
    Guidelines for packaging, marking, length tolerance, and certification of compliance ensure that suppliers and purchasers maintain high-quality standards throughout the supply chain. The document also discusses selection criteria for sampling and inspection methods by buyers.

Applications

IEC 62917:2016 is essential for organizations involved in the design, manufacture, procurement, and maintenance of electric traction overhead lines in railway systems. Key applications include:

  • Overhead contact wire production for electrified rail networks
  • Engineering and design of electric traction infrastructure
  • Quality assurance processes for railway fixed installations
  • Specification reference for tenders and contracts in railway electrification projects
  • Maintenance and replacement operations ensuring compatibility with existing standards

Railway operators, infrastructure providers, and manufacturers benefit from this standard by ensuring electric traction contact wires meet international benchmarks for performance and safety, reducing downtime and enhancing operational efficiency.

Related Standards

Professionals working with IEC 62917:2016 may also consider complementary IEC and international standards to ensure full compatibility and system integrity, such as:

  • IEC 61076 – Connectors for railway applications
  • IEC 61373 – Shock and vibration tests for railway equipment
  • EN 50119 – Overhead contact line systems for railway electrification (European Standard)
  • ISO 9001 – Quality management systems, important for manufacturing control
  • Other IEC standards governing electrical and mechanical properties of materials used in railway infrastructure

Compliance with IEC 62917:2016 in conjunction with these standards supports safe, sustainable, and interoperable railway electric traction systems worldwide.


By adhering to IEC 62917:2016, stakeholders can ensure the deployment of high-quality copper and copper alloy grooved contact wires that meet stringent international requirements. The standard plays a vital role in sustaining the performance and safety of electrified railway networks globally.

Buy Documents

Standard

IEC 62917:2016 - Railway applications - Fixed installations - Electric traction - Copper and copper alloy grooved contact wires Released:10/5/2016

ISBN:978-2-8322-3625-3
English and French language (97 pages)
sale 15% off
Preview
sale 15% off
Preview

Get Certified

Connect with accredited certification bodies for this standard

IRIS Certification (UNIFE)

International Railway Industry Standard certification.

BELAC Belgium Verified

TÜV SÜD Rail GmbH

TÜV SÜD railway certification services.

DAKKS Germany Verified

Bureau Veritas Railway Certification

Railway and transportation certification.

COFRAC France Verified

Sponsored listings

Frequently Asked Questions

IEC 62917:2016 is a standard published by the International Electrotechnical Commission (IEC). Its full title is "Railway applications - Fixed installations - Electric traction - Copper and copper alloy grooved contact wires". This standard covers: IEC 62917:2016 specifies the characteristics of copper and copper alloy grooved contact wires of cross-sections from 70 mm2 to 170 mm2 for use on overhead contact lines. It establishes the product characteristics, the test methods, checking procedures to be used with the contact wires, together with the ordering and delivery condition.

IEC 62917:2016 specifies the characteristics of copper and copper alloy grooved contact wires of cross-sections from 70 mm2 to 170 mm2 for use on overhead contact lines. It establishes the product characteristics, the test methods, checking procedures to be used with the contact wires, together with the ordering and delivery condition.

IEC 62917:2016 is classified under the following ICS (International Classification for Standards) categories: 45.060.01 - Railway rolling stock in general. The ICS classification helps identify the subject area and facilitates finding related standards.

IEC 62917:2016 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.

Standards Content (Sample)


IEC 62917 ®
Edition 1.0 2016-10
INTERNATIONAL
STANDARD
NORME
INTERNATIONALE
colour
inside
Railway applications – Fixed installations – Electric traction – Copper and
copper alloy grooved contact wires

Applications ferroviaires – Installations fixes – Traction électrique – Fils de
contact rainurés en cuivre et en cuivre allié

All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form
or by any means, electronic or mechanical, including photocopying and microfilm, without permission in writing from
either IEC or IEC's member National Committee in the country of the requester. If you have any questions about IEC
copyright or have an enquiry about obtaining additional rights to this publication, please contact the address below or
your local IEC member National Committee for further information.

Droits de reproduction réservés. Sauf indication contraire, aucune partie de cette publication ne peut être reproduite
ni utilisée sous quelque forme que ce soit et par aucun procédé, électronique ou mécanique, y compris la photocopie
et les microfilms, sans l'accord écrit de l'IEC ou du Comité national de l'IEC du pays du demandeur. Si vous avez des
questions sur le copyright de l'IEC ou si vous désirez obtenir des droits supplémentaires sur cette publication, utilisez
les coordonnées ci-après ou contactez le Comité national de l'IEC de votre pays de résidence.

IEC Central Office Tel.: +41 22 919 02 11
3, rue de Varembé Fax: +41 22 919 03 00
CH-1211 Geneva 20 info@iec.ch
Switzerland www.iec.ch
About the IEC
The International Electrotechnical Commission (IEC) is the leading global organization that prepares and publishes
International Standards for all electrical, electronic and related technologies.

About IEC publications
The technical content of IEC publications is kept under constant review by the IEC. Please make sure that you have the
latest edition, a corrigenda or an amendment might have been published.

IEC Catalogue - webstore.iec.ch/catalogue Electropedia - www.electropedia.org
The stand-alone application for consulting the entire The world's leading online dictionary of electronic and
bibliographical information on IEC International Standards, electrical terms containing 20 000 terms and definitions in
Technical Specifications, Technical Reports and other English and French, with equivalent terms in 15 additional
documents. Available for PC, Mac OS, Android Tablets and languages. Also known as the International Electrotechnical
iPad. Vocabulary (IEV) online.

IEC publications search - www.iec.ch/searchpub IEC Glossary - std.iec.ch/glossary
The advanced search enables to find IEC publications by a 65 000 electrotechnical terminology entries in English and
variety of criteria (reference number, text, technical French extracted from the Terms and Definitions clause of
committee,…). It also gives information on projects, replaced IEC publications issued since 2002. Some entries have been
and withdrawn publications. collected from earlier publications of IEC TC 37, 77, 86 and

CISPR.
IEC Just Published - webstore.iec.ch/justpublished
Stay up to date on all new IEC publications. Just Published IEC Customer Service Centre - webstore.iec.ch/csc
details all new publications released. Available online and If you wish to give us your feedback on this publication or
also once a month by email. need further assistance, please contact the Customer Service
Centre: csc@iec.ch.
A propos de l'IEC
La Commission Electrotechnique Internationale (IEC) est la première organisation mondiale qui élabore et publie des
Normes internationales pour tout ce qui a trait à l'électricité, à l'électronique et aux technologies apparentées.

A propos des publications IEC
Le contenu technique des publications IEC est constamment revu. Veuillez vous assurer que vous possédez l’édition la
plus récente, un corrigendum ou amendement peut avoir été publié.

Catalogue IEC - webstore.iec.ch/catalogue Electropedia - www.electropedia.org
Application autonome pour consulter tous les renseignements
Le premier dictionnaire en ligne de termes électroniques et
bibliographiques sur les Normes internationales,
électriques. Il contient 20 000 termes et définitions en anglais
Spécifications techniques, Rapports techniques et autres
et en français, ainsi que les termes équivalents dans 15
documents de l'IEC. Disponible pour PC, Mac OS, tablettes
langues additionnelles. Egalement appelé Vocabulaire
Android et iPad.
Electrotechnique International (IEV) en ligne.

Recherche de publications IEC - www.iec.ch/searchpub
Glossaire IEC - std.iec.ch/glossary
65 000 entrées terminologiques électrotechniques, en anglais
La recherche avancée permet de trouver des publications IEC
en utilisant différents critères (numéro de référence, texte, et en français, extraites des articles Termes et Définitions des
comité d’études,…). Elle donne aussi des informations sur les publications IEC parues depuis 2002. Plus certaines entrées
projets et les publications remplacées ou retirées. antérieures extraites des publications des CE 37, 77, 86 et

CISPR de l'IEC.
IEC Just Published - webstore.iec.ch/justpublished

Service Clients - webstore.iec.ch/csc
Restez informé sur les nouvelles publications IEC. Just
Published détaille les nouvelles publications parues. Si vous désirez nous donner des commentaires sur cette
Disponible en ligne et aussi une fois par mois par email. publication ou si vous avez des questions contactez-nous:
csc@iec.ch.
IEC 62917 ®
Edition 1.0 2016-10
INTERNATIONAL
STANDARD
NORME
INTERNATIONALE
colour
inside
Railway applications – Fixed installations – Electric traction – Copper and

copper alloy grooved contact wires

Applications ferroviaires – Installations fixes – Traction électrique – Fils de

contact rainurés en cuivre et en cuivre allié

INTERNATIONAL
ELECTROTECHNICAL
COMMISSION
COMMISSION
ELECTROTECHNIQUE
INTERNATIONALE
ICS 45.060.01 ISBN 978-2-8322-3625-3

– 2 – IEC 62917:2016 © IEC 2016
CONTENTS
FOREWORD . 5
1 Scope . 7
2 Normative references . 7
3 Terms and definitions . 7
4 Characteristics of contact wires . 8
4.1 Contact wire designation system . 8
4.2 Material designation . 8
4.3 Appearance and condition . 8
4.4 Identification . 9
4.4.1 General requirements . 9
4.4.2 Normal and high strength copper (Cu-ETP, Cu-FRHC, Cu-HCP, Cu-OF) . 9
4.4.3 Copper-silver alloy (CuAg 0,1) . 9
4.4.4 Copper-cadmium alloy (CuCd 0,7, CuCd 1,0) . 9
4.4.5 Copper-magnesium alloy (CuMg 0,2, CuMg 0,5) . 10
4.4.6 Copper-tin alloy (CuSn 0,2) . 10
4.5 Configuration, profile and cross-sections . 11
4.5.1 Clamping grooves . 11
4.5.2 Cross-sectional areas . 11
4.5.3 Profiles . 11
4.5.4 Configurations . 11
4.6 Electrical properties . 12
4.6.1 Resistivity . 12
4.6.2 Resistance per kilometre . 12
4.7 Mechanical properties . 13
4.7.1 Tensile strength and percentage elongation after fracture . 13
4.7.2 Additional requirements . 13
4.7.3 Microwaves on longitudinal axis of contact wire . 13
4.8 Jointing feed stock . 14
5 Testing of contact wires . 17
5.1 Material composition . 17
5.2 Appearance and condition . 17
5.3 Profiles and dimensions . 17
5.4 Electrical properties . 17
5.5 Mechanical properties . 17
5.5.1 Breaking load and percentage elongation after fracture . 17
5.5.2 Reverse bend test . 18
5.5.3 Torsional strength test . 20
5.5.4 Winding property test . 20
5.5.5 Microwaves on longitudinal axis of the contact wire . 20
5.6 Mass per unit length . 21
5.7 Jointing of wire . 21
5.8 Integrity of contact wire . 21
5.9 Type of tests . 21
6 Ordering and delivery conditions . 22
6.1 Conditions and specification of the order . 22
6.2 Packaging . 23

6.3 Tolerance on contact wire length . 23
6.4 Contact wire drum markings . 23
7 Verification of compliance . 23
7.1 Certification of compliance and test results . 23
7.2 Selection of samples and tests by supplier . 23
7.3 Inspection by purchaser . 24
Annex A (normative) Standardised configurations . 25
Annex B (informative) Common alloy compositions and designations . 28
Annex C (informative) Physical properties . 29
C.1 Electrical resistance per kilometre. 29
C.2 Minimum breaking load . 30
C.3 Tolerance on diameter and cross-sectional area . 30
C.4 Mass per kilometre of the contact wire . 30
C.5 Contact wire coefficients . 31
C.6 Calculating the cross-sectional area of contact wire . 32
Annex D (informative) A-deviations . 33
Annex E (informative) Special national conditions . 34
E.1 General . 34
E.2 United Kingdom . 34
E.3 Austria . 34
E.4 Japan. 36
E.5 Russia . 40
E.6 China . 44
Bibliography . 48

Figure 1 – Description of identification groove . 9
Figure 2 – Two identification grooves (CuAg) . 10
Figure 3 – One identification groove (CuCd) . 10
Figure 4 – Three identification grooves (CuMg) . 10
Figure 5 – One offset identification groove (CuSn) . 11
Figure 6 – Clamping groove types A and B . 11
Figure 7 – Limit on microwaves in the contact wire . 14
Figure 8 – Reverse bend test – Test rig . 19
Figure 9 – Reverse bend test – Method. 20
Figure A.1 – Contact wire shape AC . 25
Figure A.2 – Contact wire shape BC . 26
Figure A.3 – Contact wire shape BF . 27
Figure E.1 – Clamping groove type in Austria . 35
Figure E.2 – Configurations of CF-100 and CF-120 contact wire in Austria . 36
Figure E.3 – Identification grooves of contact wires in Japan (Copper-tin 0,3 % alloy) . 37
Figure E.4 – Clamping grooves of contact wires in Japan . 37
Figure E.5 – Configurations of contact wires in Japan . 38
Figure E.6 – Identification grooves of contact wires of type M (a), type M* (b), type Br2
(c), type Br1 (d) in Russia . 41
Figure E.7 – Clamping grooves and configuration of contact wire circular profile in
Russia . 42

– 4 – IEC 62917:2016 © IEC 2016
Figure E.8 – Clamping grooves and configuration of contact wire oval profile in Russia . 43
Figure E.9 – Cross-section and identification grooves in China . 45

Table 1 – Configurations and cross-sections for types A and B . 12
Table 2 – Maximum resistivity and minimum conductivity . 12
Table 3 – Maximum resistance per kilometre depending on material . 13
Table 4 – Tensile strength and percentage elongation after fracture . 15
Table 5 – Minimum breaking loads depending on material and cross-section . 16
Table 6 – Contact wire tests. 22
Table 7 – Guide for the selection of samples . 24
Table A.1 – Dimensions for contact wire shape AC . 25
Table A.2 – Dimensions for contact wire shape BC . 26
Table A.3 – Dimensions for contact wire shape BF . 27
Table B.1 – Some possible material compositions and designations . 28
Table C.1 – Maximum electrical resistance per kilometre depending on conductivity

and nominal cross-section (examples) . 29
Table C.2 – Minimum breaking loads depending on tensile strength and nominal
cross-section (examples) . 30
Table C.3 – Contact wire mass . 31
Table E.1 – Dimensions of identification grooves in Japan . 37
Table E.2 – Dimensions of clamping grooves in Japan . 38
Table E.3 – Designations of contact wires in Japan . 38
Table E.4 – Dimensions of contact wires in Japan . 39
Table E.5 – Mechanical properties of contact wires in Japan . 39
Table E.6 – Mass of contact wires in Japan . 40
Table E.7 – Dimensions and mass per unit length of contact wires in Russia . 43
Table E.8 – Mechanical and electrical properties for contact wires of type M in Russia . 44
Table E.9 – Mechanical and electrical properties for contact wires of types Br1, Br2 in
Russia . 44
Table E.10 – Gauge, dimensions, angle and referenced mass per unit length in China . 45
Table E.11 – Designations of contact wires in China . 46
Table E.12 – Mechanical properties of contact wires in China . 46

INTERNATIONAL ELECTROTECHNICAL COMMISSION
____________
RAILWAY APPLICATIONS – FIXED INSTALLATIONS – ELECTRIC
TRACTION – COPPER AND COPPER ALLOY GROOVED CONTACT WIRES

FOREWORD
1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of IEC is to promote
international co-operation on all questions concerning standardization in the electrical and electronic fields. To
this end and in addition to other activities, IEC publishes International Standards, Technical Specifications,
Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC
Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested
in the subject dealt with may participate in this preparatory work. International, governmental and non-
governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely
with the International Organization for Standardization (ISO) in accordance with conditions determined by
agreement between the two organizations.
2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international
consensus of opinion on the relevant subjects since each technical committee has representation from all
interested IEC National Committees.
3) IEC Publications have the form of recommendations for international use and are accepted by IEC National
Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC
Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any
misinterpretation by any end user.
4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications
transparently to the maximum extent possible in their national and regional publications. Any divergence
between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in
the latter.
5) IEC itself does not provide any attestation of conformity. Independent certification bodies provide conformity
assessment services and, in some areas, access to IEC marks of conformity. IEC is not responsible for any
services carried out by independent certification bodies.
6) All users should ensure that they have the latest edition of this publication.
7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and
members of its technical committees and IEC National Committees for any personal injury, property damage or
other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and
expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC
Publications.
8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is
indispensable for the correct application of this publication.
9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of
patent rights. IEC shall not be held responsible for identifying any or all such patent rights.
International Standard IEC 62917 has been prepared by IEC technical committee 9: Electrical
equipment and systems for railways.
This first edition is based on European standard EN 50149:2012.
The main technical changes with regard to EN 50149:2012 are as follows:
• extended range of cross-sections,
• changed terms and definitions,
• additional electrical and mechanical properties,
• additional special national conditions,
• for grooved contact wires.
– 6 – IEC 62917:2016 © IEC 2016
The text of this standard is based on the following documents:
FDIS Report on voting
9/2191/FDIS 9/2202/RVD
Full information on the voting for the approval of this standard can be found in the report on
voting indicated in the above table.
This publication has been drafted in accordance with the ISO/IEC Directives, Part 2.
The committee has decided that the contents of this publication will remain unchanged until
the stability date indicated on the IEC website under "http://webstore.iec.ch" in the data
related to the specific publication. At this date, the publication will be
• reconfirmed,
• withdrawn,
• replaced by a revised edition, or
• amended.
IMPORTANT – The 'colour inside' logo on the cover page of this publication indicates
that it contains colours which are considered to be useful for the correct
understanding of its contents. Users should therefore print this document using a
colour printer.
RAILWAY APPLICATIONS – FIXED INSTALLATIONS – ELECTRIC
TRACTION – COPPER AND COPPER ALLOY GROOVED CONTACT WIRES

1 Scope
This International Standard specifies the characteristics of copper and copper alloy grooved
2 2
contact wires of cross-sections from 70 mm to 170 mm for use on overhead contact lines.
It establishes the product characteristics, the test methods, checking procedures to be used
with the contact wires, together with the ordering and delivery condition.
2 Normative references
The following documents, in whole or in part, are normatively referenced in this document and
are indispensable for its application. For dated references, only the edition cited applies. For
undated references, the latest edition of the referenced document (including any
amendments) applies.
IEC 60468:1974, Method of measurement of resistivity of metallic materials
ISO 6892-1, Metallic materials – Tensile testing – Part 1: Method of test at room temperature
ISO 7801:1984, Metallic materials – Wire – Reverse bend test
3 Terms and definitions
For the purposes of this document, the following terms and definitions apply.
3.1
feed stock
wire of a shape, whose cross-section is generally larger than the grooved wire cross-section,
from which the contact wire is then drawn and/or rolled
3.2
sideways-coiled contact wire
contact wire coiled with vertical axis parallel or in an angle to the axis of the drum
3.3
perpendicularly coiled contact wire
contact wire coiled with the vertical axis perpendicular to the axis of the drum facing the drum
with the bottom arc
3.4
joint
connection between feed stock wires before cold drawing
3.5
joint area
area of the contact wire influenced by a joint

– 8 – IEC 62917:2016 © IEC 2016
3.6
contact wire
electric conductor of an overhead contact line with which the current collector makes contact
[SOURCE: IEC 60050-811:1991, 811-33-15]
3.7
grooved contact wire
contact wire characterised by two clamping grooves
Note 1 to entry: The contact wire hereinafter refers to a grooved contact wire according the scope of this
International Standard.
4 Characteristics of contact wires
4.1 Contact wire designation system
The contact wire designation shall consist of:
• denomination (contact wire);
• number of this International Standard (IEC 62917);
• configuration designation (see 4.5.4);
• material designation, either symbol or number (see Table B.1, or material as agreed
between purchaser and supplier);
• minimum tensile strength in MPa or minimum breaking load in kN;
• minimum conductivity in % IACS or maximum resistance per km in Ω/km.
EXAMPLE Contact wire IEC 62917 – AC-120 – CuMg0,5 – Strength 490 (MPa) – Conductivity 62 (% IACS).
4.2 Material designation
NOTE The contact wire shall consist of a copper or copper silver alloy, as defined for example in EN 1977:2013
(only for CEN/CENLEC members) or another copper alloy.
Annex B gives the designations of the feed stocks for some possible compositions of the
contact wire. At the time of tender, the user shall specify explicitly the material(s) he wants or
he is allowed to apply.
Copper cadmium alloys are not recommended for use for environmental reason, see Annex D.
4.3 Appearance and condition
The contact wires shall not present any imperfections (roughness, sliver, seam, inclusion,
cracks, kinks, or sharp cutting edges) liable to affect the mechanical and/or electrical
properties specified in this Standard or to cause difficulties during installation/operation.
The groove shall be even and without warp.
The surface shall be clean and free of oxide inclusions or sulphide generated during the
manufacturing process or foreign substances such as pickling residue.
The colour of the metallic bright surface immediately after manufacturing may change due to
atmospheric influence. This is acceptable.

4.4 Identification
4.4.1 General requirements
All contact wires manufactured from alloys shall be clearly identified except when there is
another agreement between purchaser and supplier. For normal and high strength copper and
copper-silver, copper-cadmium, copper-magnesium and copper-tin alloys the method of
identification shall be by identification grooves as shown below. For other alloys the
identification method (whether grooves or other method) shall be agreed between purchaser
and supplier.
Identification grooves shall be set out as shown in Figure 1. The centre of the middle circle
shall be on the projected circle of the contact wire. The connection between two successive
arcs shall be without a straight line.
1 2
IEC
Key
1 diameter of contact wire
2 tangential connection between successive arcs
Figure 1 – Description of identification groove
4.4.2 Normal and high strength copper (Cu-ETP, Cu-FRHC, Cu-HCP, Cu-OF)
Contact wires of copper have no identification groove .
4.4.3 Copper-silver alloy (CuAg 0,1)
NOTE Contact wires of copper alloy with silver shall incorporate two identification grooves on the upper lobe of the
contact wire in accordance with Figure 2 (only for CEN/CENELEC members, other countries see Annex E).
4.4.4 Copper-cadmium alloy (CuCd 0,7, CuCd 1,0)
Contact wires of copper alloy with cadmium shall incorporate one identification groove on the
upper lobe of the contact wire in accordance with Figure 3 .
This identification is only used for already installed contact wires. This identification should
not be used for other copper-alloys (see also Annexes C and D).
___________
See Annex E, Special National Condition for United Kingdom.

– 10 – IEC 62917:2016 © IEC 2016
4.4.5 Copper-magnesium alloy (CuMg 0,2, CuMg 0,5)
NOTE Contact wires of copper alloy with magnesium shall incorporate three identification grooves on the upper
lobe of the contact wire in accordance with Figure 4 (only for CEN/CENELEC members, other countries see Annex
E).
4.4.6 Copper-tin alloy (CuSn 0,2)
NOTE Contact wires of copper alloy with tin shall incorporate one identification groove set at an angle of 24° on
the upper lobe of the contact wire in accordance with Figure 5 (only for CEN/CENELEC members, other countries
see Annex E).
Dimensions in millimetres
48°
R0,25
R0,25
IEC
Figure 2 – Two identification grooves (CuAg)
Dimensions in millimetres
R 0,50
R0,25
IEC
Figure 3 – One identification groove (CuCd)
Dimensions in millimetres
48°
R0,25
R0,25
IEC
Figure 4 – Three identification grooves (CuMg)

Dimensions in millimetres
24°
R0,25
R0,25
IEC
Figure 5 – One offset identification groove (CuSn)
4.5 Configuration, profile and cross-sections
4.5.1 Clamping grooves
Whatever cross-section of the contact wire is used, the dimensions of the clamping grooves
shall be in accordance with for either type A or type B as given in Figure 6, or others clamping
groove types as given in Annex E for the mentioned countries.
Dimensions in millimetres
≤10 ≤10
R0,4
R0,4
0°    0°
51° –2° 51° –2°
5,6 ±0,2 6,92 ±0,2
R0,4 R0,4
0°
0°
6,48
27° –2° 5,14
27° –2°
IEC IEC
Type A clamping groove Type B clamping groove
Figure 6 – Clamping groove types A and B
4.5.2 Cross-sectional areas
2 2 2
This Standard details the following nominal cross-sections: 70 mm , 80 mm , 85 mm ,
2 2 2 2 2 2
100 mm , 107 mm , 110 mm , 120 mm , 150 mm and 170 mm .
4.5.3 Profiles
Profiles are of two main types, the circular profile and the flattened profile. Other profiles shall
be permitted by agreement between purchaser and supplier.
4.5.4 Configurations
The configurations of the contact wires shall be in conformance with Table 1 for types A and B
or with Annex E for other profile types in the mentioned countries. These are defined as
combinations of the profile shape, the nominal cross-section and the type of clamping groove.
The dimensions of each configuration are shown in Annex A or Annex E.
≤4,2
≤4,5
– 12 – IEC 62917:2016 © IEC 2016
Table 1 – Configurations and cross-sections for types A and B
Nominal Clamping groove Clamping groove
cross-section Type A Type B
mm Circular Circular Flat
Designation Figure No. in Designation Figure No. in Designation Figure No.
Annex A Annex A in Annex A
80 AC-80
100 AC-100 BC-100 BF-100
107 AC-107 A.1 BC-107 BF-107
A.2 A.3
120 AC-120 BC-120 BF-120
150 AC-150 BC-150 BF-150
4.6 Electrical properties
4.6.1 Resistivity
The resistivity of the contact wire at 20 °C shall not exceed the values in Table 2 for alloys
listed in Annex B. For other copper alloys the values shall be as agreed between purchaser
and supplier.
Table 2 – Maximum resistivity and minimum conductivity
−8
Material Resistivity in 10 Min. conductivity Min. conductivity
Ωm max. 10 S/m % IACS
Cu-ETP 1,777 56,3 97,0
Cu-FRHC 1,777 56,3 97,0
Cu-HCP 1,777 56,3 97,0
Cu-OF 1,777 56,3 97,0
CuAg0,1 1,777 56,3 97,0
CuMg0,2 (Normal conductivity 77,0 % IACS) 2,240 44,6 77,0
CuMg0,2 (High conductivity 80,0 % IACS) 2,155 46,4 80,0
CuMg0,5 (Normal conductivity 62,1 % IACS) 2,778 36,0 62,1
CuMg0,5 (High conductivity 70,0 % IACS) 2,463 40,6 70,0
CuSn0,2 (Normal conductivity 72,0 % IACS) 2,395 41,8 72,0
a
CuSn0,2 (High conductivity 80,0 % IACS) 2,155 46,4 80,0
CuCd0,7 2,005 49,9 86,0
CuCd1,0 2,155 46,4 80,0
a
CuSn0,2 (high conductivity) was previously denoted CuSn0,4.

4.6.2 Resistance per kilometre
The resistance per unit length at 20 °C shall not exceed the resistance value specified in
Table 3 for materials listed in Annex B. For other copper alloys the values shall be as agreed
between purchaser and supplier.
Values for electrical resistance per kilometre depending on conductivity and cross-section are
given in Table C.1. The calculation used to determine the electrical resistance per kilometre
at 20 °C is specified in Clause C.1 and is based on the values of resistivity in Table 2. The
value of resistance at a joint area shall be no greater than specified for the contact wire
material.
Table 3 – Maximum resistance per kilometre depending on material
a
Material designation
CuCd1,0
Nominal
CuSn0,2 (high
cross- Cu-ETP CuMg0,5 b
conductivity)
section Cu-OF (High
Cu-FRHC conduc- CuMg0,2 (high
mm
Cu-HCP CuAg0,1 CuMg0,2 CuMg0,5 tivity) CuSn0,2 CuCd0,7 conductivity)
97,0 % 97,0 % 77,0 % 62,1 % 70,0 % 72,0 % 86,0 % 80,0 % IACS
IACS IACS IACS IACS IACS IACS IACS
80 0,229 0,229 0,289 0,358 0,317 0,309 0,258 0,278
100 0,183 0,183 0,231 0,286 0,254 0,247 0,207 0,222
107 0,171 0,171 0,216 0,268 0,237 0,231 0,193 0,208
120 0,153 0,153 0,192 0,239 0,212 0,206 0,172 0,185
150 0,122 0,122 0,154 0,191 0,169 0,165 0,138 0,148
a
Values in Ω/km at 20°C − Calculated on minimum cross-sectional area (97 % of the nominal cross-section).
b
CuSn0,2 (high conductivity) was previously denoted CuSn0,4.
For calculation formula, see Annex C.

4.7 Mechanical properties
4.7.1 Tensile strength and percentage elongation after fracture
The tensile strength and percentage elongation after fracture of the contact wire shall be in
accordance with the values indicated in Table 4 for alloys listed in Annex B. For other copper
alloys the values shall be as agreed between purchaser and supplier. Maximum percentage
elongation values after fracture are recommended.
Table 5 shows the minimum values of calculated breaking load to be expected in tensile tests
for alloys listed in Annex B, corresponding to the minimum tensile strength shown in Table 4.
Values for minimum breaking load dependent upon tensile strength and cross-section are
given in Table C.2.
The value of tensile strength and the values for the percentage elongation after fracture at a
joint area shall be in accordance with the specified values of the contact wire material.
4.7.2 Additional requirements
The contact wire shall withstand reverse bend loads, torsional loads and winding loads. These
requirements should be tested in accordance with 5.5.2, 5.5.3 and 5.5.4 subject to agreement
between purchaser and supplier.
4.7.3 Microwaves on longitudinal axis of contact wire
The contact wire longitudinal axis shall not show any inadmissible microwaves. After
manufacturing, the vertical variation of the longitudinal axis of the contact wire should be not
more than 0,1 mm as shown in Figure 7, subject to agreement between purchaser and
supplier.
– 14 – IEC 62917:2016 © IEC 2016
Dimensions in millimetres
W
L = 1 000
IEC
Key
W contact wire
L basis length for measurement in mm
h maximum variation of longitudinal axis in mm
max
Figure 7 – Limit on microwaves in the contact wire
This requirement shall be tested in accordance with 5.5.5 subject to agreement between
purchaser and supplier.
NOTE This problem appears mainly in high strength copper alloys (minimum tensile strength > 400 MPa).
4.8 Jointing feed stock
Direct jointing of contact wire is not permitted. Joints in the feed stock which will remain in the
contact wire are permitted except otherwise specified by the purchaser if the tests according
to 5.7 are passed successfully. The type of joint shall be agreed with the purchaser.
h ≤ 0,1
max
Table 4 – Tensile strength and percentage elongation after fracture
Nominal Percentage elongation Minimum
Material Designation
cross-section after fracture A tensile strength
2 a
mm min. % max. % MPa
80 3 10 355
Cu-ETP
100 3 10 355
Cu-FRHC
Normal strength
107 3 10 350
copper
Cu-HCP
120 3 10 330
Cu-OF
150 3 10 310
Cu-ETP 80 3 8 375
High strength Cu-FRHC 100 3 8 375
copper and high
Cu-HCP 107 3 8 360
strength copper-
silver alloy Cu-OF 120 3 8 360
CuAg0,1 150 3 8 360
80 3 10 365
100 3 10 360
Normal strength
CuAg0,1 107 3 10 350
copper-silver alloy
120 3 10 350
150 3 10 350
80 3 10 460
100 3 10 450
CuMg0,2
Copper-magnesium
107 3 10 440
CuMg0,2 (high
alloy
conductivity)
120 3 10 430
150 3 10 420
80 3 10 520
100 3 10 510
CuMg0,5
Copper-magnesium
107 3 10 500
CuMg0,5 (high
alloy
conductivity)
120 3 10 490
150 3 10 470
80 2 8 460
100 2 8 450
CuSn0,2
Copper-tin alloy 107 2 8 430
CuSn0,2 (high
b
conductivity)
120 2 8 420
150 2 8 420
80 2 7 430
100 2 7 430
Copper-cadmium
CuCd0,7 107 2 7 430
alloy
120 2 7 430
150 2 7 430
80 2 7 455
100 2 7 445
Copper-cadmium
CuCd1,0 107 2 7 445
alloy
120 2 7 445
150 2 7 445
a 2.
MPa = 1 N/mm
b
CuSn0,2 (high conductivity) was previously denoted CuSn0,4.

– 16 – IEC 62917:2016 © IEC 2016
Table 5 – Minimum breaking loads depending on material and cross-section
a
Nominal cross-section Minimum breaking load
Material Designation
mm kN
80 27,5
Cu-ETP
100 34,5
Cu-FRHC
Normal strength copper 107 36,3
Cu-HCP
120 38,4
Cu-OF
150 45,1
Cu-ETP 80 29,1
Cu-FRHC 100 36,4
High strength copper and
Cu-HCP 107 37,4
high strength copper-
silver alloy
Cu-OF 120 41,9
CuAg0,1 150 52,4
80 28,3
100 34,9
Normal strength copper-
CuAg0,1 107 36,3
silver alloy
120 40,7
150 50,9
80 35,7
100 43,7
CuMg0,2
Copper-magnesium alloy 107 45,7
CuMg0,2 (high
conductivity)
120 50,1
150 61.1
80 40,4
100 49,5
CuMg0,5
Copper-magnesium alloy 107 51,9
CuMg0,5 (high
conductivity)
120 57,0
150 68,4
80 35,7
100 43,7
CuSn0,2
Copper-tin alloy 107 44,6
CuSn0,2 (high
b
conductivity)
120 48,9
150 61,1
80 33,4
100 41,7
Copper-cadmium alloy CuCd0,7 107 44,6
120 50,1
150 62.6
80 35,3
100 43,2
Copper-cadmium alloy CuCd1,0 107 46,2
120 51,8
150 64,7
a
Calculated on minimum cross-sectional area which is 97 % of the nominal cross-sectional area. For other
minimum cross-sectional areas see Annex E.
b
CuSn0,2 (high conductivity) was previously denoted CuSn0,4.

NOTE 1 Because of a possible link between the creep of the contact wires and the maximum percentage
elongation at fracture value (Table 4), the maximum elongation has been retained in this Standard. These are
indicative values only, unless otherwise agreed between purchaser and supplier.
NOTE 2 The calculations used to determine the figures in Table 5 are specified in Clause C.2. The minimum
cross-section of the contact wire has been taken into consideration, see Clause C.3.

NOTE 3 The minimum specified breaking load corresponds to the maximum force (F ) as defined in ISO 6892-1.
m
5 Testing of contact wires
5.1 Material composition
The supplier shall submit a certificate for the production lot to confirm the material
composition is in accordance with Annex B or the requirements agreed between purchaser
and supplier.
5.2 Appearance and condition
The contact wire together with each sample which is subjected to other tests identified in this
standard shall be examined with normal vision. The appearance shall comply with the
requirements of 4.3.
5.3 Profiles and dimensions
Dimensional examination shall be performed either using a suitable micrometer or sliding
caliper, or using a profile reflector with a minimum amplification of 10, or other appropriate
methods.
5.4 Electrical properties
The resistivity or resistance per unit length measurements shall be made in conformity with
IEC 60468:1974. The results shall be in accordance with 4.6.1 or 4.6.2 as appropriate.
The coefficient of temperature for the measurement of resistance at temperatures other than
shown in 4.6.1 and 4.6.2 should be:
−3
For copper (Cu-ETP, hard drawn):
3,8 × 10 /K
−3
For copper with silver (CuAg0,1): 3,8 × 10 /K
−3
For copper with magnesium (CuMg0,2, CuMg0,2 high conductivity): 3,1 × 10 /K
−3
For copper with magnesium (CuMg0,5, CuMg0,5 high conductivity):
2,7 × 10 /K
−3
For copper with tin (CuSn0,2, CuSn0,2 high conductivity):
3,2 × 10 /K
For other copper alloys the values should be as agreed between purchaser and supplier.
In a temperature range from −5
...