Amendment 1 - Degrees of protection provided by enclosures (IP Code)

Amendement 1 - Degrés de protection procurés par les enveloppes (Code IP)

General Information

Status
Published
Publication Date
15-Nov-1999
Current Stage
PPUB - Publication issued
Start Date
15-Dec-1999
Completion Date
16-Nov-1999
Ref Project

Buy Standard

Standard
IEC 60529:1989/AMD1:1999 - Amendment 1 - Degrees of protection provided by enclosures (IP Code)
English and French language
7 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

NORME CEI
INTERNATIONALE IEC
60529
INTERNATIONAL
1989
STANDARD
AMENDEMENT 1
AMENDMENT 1
1999-11
Amendement 1
Degrés de protection procurés par les enveloppes
(Code IP)
Amendment 1
Degrees of protection provided by enclosures
(IP Code)
 IEC 1999 Droits de reproduction réservés  Copyright - all rights reserved
International Electrotechnical Commission 3, rue de Varembé Geneva, Switzerland
Telefax: +41 22 919 0300 e-mail: inmail@iec.ch IEC web site http://www.iec.ch
CODE PRIX
Commission Electrotechnique Internationale
D
PRICE CODE
International Electrotechnical Commission
Pour prix, voir catalogue en vigueur
For price, see current catalogue

---------------------- Page: 1 ----------------------
– 2 – 60529 amend. 1  CEI:1999
AVANT-PROPOS
Le présent amendement a été établi par le comité d’études 70 de la CEI: Degrés de protection
procurés par les enveloppes.
Le texte du présent amendement est issu des documents suivants:
FDIS Rapport de vote
70/91/FDIS 70/92/RVD
Le rapport de vote indiqué dans le tableau ci-dessus donne toute information sur le vote ayant
abouti à l’approbation du présent amendement.
___________
Page 6
Modifier le titre de l'article 1 comme suit:
1 Domaine d'application et objet
Supprimer le titre de l'article 2 «Objet»
Ajouter, à la page 8, à la fin du cinquième alinéa du point d), ce qui suit:
«. à protéger».
Page 8
Ajouter le nouvel article 2 suivant:
2 Références normatives
Les documents normatifs suivants contiennent des dispositions qui, par suite de la référence
qui y est faite, constituent des dispositions valables pour la présente Norme internationale.
Pour les références datées, les amendements ultérieurs ou les révisions de ces publications
ne s’appliquent pas. Toutefois, les parties prenantes aux accords fondés sur la présente
Norme internationale sont invitées à rechercher la possibilité d'appliquer les éditions les plus
récentes des documents normatifs indiqués ci-après. Pour les références non datées, la
dernière édition du document normatif en référence s’applique. Les membres de la CEI et de
l'ISO possèdent le registre des Normes internationales en vigueur.
CEI 60050-195:1998, Vocabulaire Electrotechnique International (VEI): Partie 195: Mise à la
terre et protection contre les chocs électriques
CEI 60050(826):1982, Vocabulaire Electrotechnique International (VEI): Chapitre 826:
Installations électriques des bâtiments
CEI 60068-1:1988, Essais d’environnement – Partie 1: Généralités et guide
CEI 60068-2-68:1994, Essais d’environnement – Partie 2: Essais – Essai L: Poussière et sable
CEI 60071-2:1996, Coordination de l’isolement – Partie 2: Guide d’application

---------------------- Page: 2 ----------------------
60529 Amend. 1  IEC:1999 – 3 –
FOREWORD
This amendment has been prepared by IEC technical committee 70: Degrees of protection
provided by enclosures.
The text of this amendment is based on the following documents:
FDIS Report on voting
70/91/FDIS 70/92/RVD
Full information on the voting for the approval of this amendment can be found in the report on
voting indicated in the above table.
___________
Page 7
Modify the title of clause 1 as follows:
1 Scope and object
Delete the title of clause 2 "Object"
Add, on page 9, at the end of the fifth paragraph of item d), the following:
". to be protected".
Page 9
Add the following new clause 2:
2 Normative references
The following normative documents contain provisions which, through reference in this text,
constitute provisions of this International Standard. For dated references, subsequent
amendments to, or revisions of, any of these publications do not apply. However, parties to
agreements based on this International Standard are encouraged to investigate the possibility
of applying the most recent editions of the normative documents indicated below. For undated
references, the latest edition of the normative document referred to applies. Members of IEC
and ISO maintain registers of currently valid International Standards.
IEC 60050-195:1998, International Electrotechnical Vocabulary (IEV): Part 195: Earthing and
protection against electric shock
IEC 60050(826):1982, International Electrotechnical Vocabulary (IEV): Chapter 826: Electrical
installations of buildings
IEC 60068-1:1988, Environmental testing – Part 1: General and guidance
IEC 60068-2-68:1994, Environmental testing – Part 2: Tests – Test L: Dust and sand
IEC 60071-2:1996, Insulation co-ordination – Part 2: Application guide

---------------------- Page: 3 ----------------------
– 4 – 60529 amend. 1  CEI:1999
Page 10
3.5.1 Partie active dangereuse
Remplacer le texte entre parenthèses «(voir CEI 536, actuellement document 64(BC)196)»
par «(voir la CEI 60050-195, 195-06-05)».
Page 18
Tableau I
Remplacer la note par ce qui suit:
NOTE Dans les cas des premiers chiffres caractéristiques 3, 4, 5 et 6, la protection contre l’accès aux parties
dangereuses est satisfaite si une distance suffisante est maintenue. Il convient que la distance s
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.