IEC 61169-53:2015
(Main)Radio-frequency connectors - Part 53: Sectional specification for RF coaxial connectors with inner diameter of outer conductor 16 mm with screw lock - Characteristic impedance 50 Ω (Type S7-16)
General Information
- Abstract
IEC 61169-53:2015 is a sectional specification which provides information and rules for the preparation of detail specifications (DS) for RF coaxial connectors with threaded coupling, typically for use in 50 Ohms cable networks (Type S7-16).
- Status
- Published
- Publication Date
- 15-Sep-2015
- Technical Committee
- SC 46F - RF and microwave passive components
- Drafting Committee
- PT 61169-53 - TC 46/SC 46F/PT 61169-53
- Current Stage
- PPUB - Publication issued
- Start Date
- 16-Sep-2015
- Completion Date
- 30-Nov-2015
Buy Documents
IEC 61169-53:2015 - Radio-frequency connectors - Part 53: Sectional specification for RF coaxial connectors with inner diameter of outer conductor 16 mm with screw lock - Characteristic impedance 50 ? (Type S7-16) Released:9/16/2015
Overview
IEC 61169-53:2015 is an international standard published by the International Electrotechnical Commission (IEC) that specifies requirements for radio-frequency (RF) coaxial connectors with a 16 mm inner diameter outer conductor, featuring screw lock mechanisms and a characteristic impedance of 50 Ohms. Known by the designation Type S7-16, these connectors are primarily utilized in 50 Ohm cable networks for high-performance RF and microwave transmission systems. This sectional specification provides detailed guidance for the preparation of detail specifications (DS), encompassing dimensional, performance, and testing parameters for these RF coaxial connectors.
Key Topics
- Connector Designation: Specifies Type S7-16 RF coaxial connectors with a 16 mm inner diameter of the outer conductor and threaded coupling for secure connections.
- Characteristic Impedance: Standardized at 50 Ω, suitable for most professional RF and microwave applications.
- Applications: Intended for connection with RF cables and microstrips within microwave transmission systems.
- Performance Criteria: Includes requirements for mating face dimensions, electrical and mechanical properties, and climate resistance.
- Quality Assessment: Outlines comprehensive test schedules and inspection requirements for quality assurance at different assessment levels.
- Detail Specification Guidance: Provides standardized templates and rules for creating detail specifications applicable to variations within the S7-16 connector family.
- Testing References: Incorporates references to IEC 61169-1 (generic requirements) and IEC 62037 (intermodulation measurement).
Applications
The IEC 61169-53:2015 standard supports a wide range of practical uses in telecommunications and RF engineering:
- High-frequency Cable Networks: Used for connecting cables, antennas, and devices in professional wireless, cellular, and broadcast infrastructures.
- Microwave Transmission Systems: Suitable for RF interconnections up to 7.5 GHz, ensuring reliable signal integrity at high frequencies.
- Industrial and Laboratory Equipment: Ideal for test and measurement setups requiring consistent connector performance and repeatability.
- Installation and Maintenance: Facilitates standardization, allowing for interoperability and easier maintenance or replacement of connectors in field deployments.
By adhering to IEC 61169-53:2015, manufacturers and engineers ensure that connectors are compatible with industry practices, maintain high reliability, and meet safety and performance benchmarks essential for RF systems.
Related Standards
To ensure complete and reliable specification and performance, the following related IEC standards should be considered alongside IEC 61169-53:2015:
- IEC 61169-1: Radio-frequency connectors – Part 1: Generic specification – General requirements and measuring methods
- IEC 62037: Passive RF and microwave devices – Intermodulation level measurement
- IEC 61169 series: Other parts in the IEC 61169 series may address alternative connector sizes, coupling mechanisms, and impedance types relevant to different system requirements.
Practical Value
Implementing IEC 61169-53:2015 provides significant practical benefits, such as:
- Component Interchangeability: Assures consistent connector sizing and performance, reducing procurement and integration challenges.
- Quality Assurance: Standardized test methods and inspection levels promote lasting reliability and minimize risks of RF signal degradation or failure.
- International Compatibility: Adoption of IEC standards facilitates global trade, system integration, and cross-border projects with harmonized product expectations.
- Efficient Product Development: Clear templates and rules streamline specification writing and connector manufacturing, boosting productivity and reducing time-to-market.
For engineers, manufacturers, and network operators, IEC 61169-53:2015 is a critical reference for selecting and specifying high-performance RF coaxial connectors in demanding electrical and electronic applications.
Buy Documents
IEC 61169-53:2015 - Radio-frequency connectors - Part 53: Sectional specification for RF coaxial connectors with inner diameter of outer conductor 16 mm with screw lock - Characteristic impedance 50 ? (Type S7-16) Released:9/16/2015
Get Certified
Connect with accredited certification bodies for this standard

ANCE
Mexican certification and testing association.

Intertek Slovenia
Intertek testing, inspection, and certification services in Slovenia.
LNE (Laboratoire National de Métrologie et d'Essais)
French national laboratory for metrology and testing.
Sponsored listings
Frequently Asked Questions
IEC 61169-53:2015 is a standard published by the International Electrotechnical Commission (IEC). Its full title is "Radio-frequency connectors - Part 53: Sectional specification for RF coaxial connectors with inner diameter of outer conductor 16 mm with screw lock - Characteristic impedance 50 Ω (Type S7-16)". This standard covers: IEC 61169-53:2015 is a sectional specification which provides information and rules for the preparation of detail specifications (DS) for RF coaxial connectors with threaded coupling, typically for use in 50 Ohms cable networks (Type S7-16).
IEC 61169-53:2015 is a sectional specification which provides information and rules for the preparation of detail specifications (DS) for RF coaxial connectors with threaded coupling, typically for use in 50 Ohms cable networks (Type S7-16).
IEC 61169-53:2015 is classified under the following ICS (International Classification for Standards) categories: 33.120.30 - RF connectors. The ICS classification helps identify the subject area and facilitates finding related standards.
IEC 61169-53:2015 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
IEC 61169-53 ®
Edition 1.0 2015-09
INTERNATIONAL
STANDARD
NORME
INTERNATIONALE
colour
inside
Radio-frequency connectors –
Part 53: Sectional specification for RF coaxial connectors with inner diameter of
outer conductor 16 mm with screw lock – Characteristic impedance 50 Ω (Type
S7-16)
Connecteurs pour fréquences radioélectriques –
Partie 53: Spécification intermédiaire relative aux connecteurs coaxiaux pour
fréquences radioélectriques avec diamètre intérieur des conducteurs extérieurs
de 16 mm à verrouillage à vis – Impédance caractéristique 50 Ω (Type S7-16)
All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form
or by any means, electronic or mechanical, including photocopying and microfilm, without permission in writing from
either IEC or IEC's member National Committee in the country of the requester. If you have any questions about IEC
copyright or have an enquiry about obtaining additional rights to this publication, please contact the address below or
your local IEC member National Committee for further information.
Droits de reproduction réservés. Sauf indication contraire, aucune partie de cette publication ne peut être reproduite
ni utilisée sous quelque forme que ce soit et par aucun procédé, électronique ou mécanique, y compris la photocopie
et les microfilms, sans l'accord écrit de l'IEC ou du Comité national de l'IEC du pays du demandeur. Si vous avez des
questions sur le copyright de l'IEC ou si vous désirez obtenir des droits supplémentaires sur cette publication, utilisez
les coordonnées ci-après ou contactez le Comité national de l'IEC de votre pays de résidence.
IEC Central Office Tel.: +41 22 919 02 11
3, rue de Varembé Fax: +41 22 919 03 00
CH-1211 Geneva 20 info@iec.ch
Switzerland www.iec.ch
About the IEC
The International Electrotechnical Commission (IEC) is the leading global organization that prepares and publishes
International Standards for all electrical, electronic and related technologies.
About IEC publications
The technical content of IEC publications is kept under constant review by the IEC. Please make sure that you have the
latest edition, a corrigenda or an amendment might have been published.
IEC Catalogue - webstore.iec.ch/catalogue Electropedia - www.electropedia.org
The stand-alone application for consulting the entire The world's leading online dictionary of electronic and
bibliographical information on IEC International Standards, electrical terms containing more than 30 000 terms and
Technical Specifications, Technical Reports and other definitions in English and French, with equivalent terms in 15
documents. Available for PC, Mac OS, Android Tablets and additional languages. Also known as the International
iPad. Electrotechnical Vocabulary (IEV) online.
IEC publications search - www.iec.ch/searchpub IEC Glossary - std.iec.ch/glossary
The advanced search enables to find IEC publications by a More than 60 000 electrotechnical terminology entries in
variety of criteria (reference number, text, technical English and French extracted from the Terms and Definitions
committee,…). It also gives information on projects, replaced clause of IEC publications issued since 2002. Some entries
and withdrawn publications. have been collected from earlier publications of IEC TC 37,
77, 86 and CISPR.
IEC Just Published - webstore.iec.ch/justpublished
Stay up to date on all new IEC publications. Just Published IEC Customer Service Centre - webstore.iec.ch/csc
details all new publications released. Available online and If you wish to give us your feedback on this publication or
also once a month by email. need further assistance, please contact the Customer Service
Centre: csc@iec.ch.
A propos de l'IEC
La Commission Electrotechnique Internationale (IEC) est la première organisation mondiale qui élabore et publie des
Normes internationales pour tout ce qui a trait à l'électricité, à l'électronique et aux technologies apparentées.
A propos des publications IEC
Le contenu technique des publications IEC est constamment revu. Veuillez vous assurer que vous possédez l’édition la
plus récente, un corrigendum ou amendement peut avoir été publié.
Catalogue IEC - webstore.iec.ch/catalogue Electropedia - www.electropedia.org
Application autonome pour consulter tous les renseignements
Le premier dictionnaire en ligne de termes électroniques et
bibliographiques sur les Normes internationales,
électriques. Il contient plus de 30 000 termes et définitions en
Spécifications techniques, Rapports techniques et autres
anglais et en français, ainsi que les termes équivalents dans
documents de l'IEC. Disponible pour PC, Mac OS, tablettes
15 langues additionnelles. Egalement appelé Vocabulaire
Android et iPad.
Electrotechnique International (IEV) en ligne.
Recherche de publications IEC - www.iec.ch/searchpub
Glossaire IEC - std.iec.ch/glossary
Plus de 60 000 entrées terminologiques électrotechniques, en
La recherche avancée permet de trouver des publications IEC
en utilisant différents critères (numéro de référence, texte, anglais et en français, extraites des articles Termes et
comité d’études,…). Elle donne aussi des informations sur les Définitions des publications IEC parues depuis 2002. Plus
projets et les publications remplacées ou retirées. certaines entrées antérieures extraites des publications des
CE 37, 77, 86 et CISPR de l'IEC.
IEC Just Published - webstore.iec.ch/justpublished
Service Clients - webstore.iec.ch/csc
Restez informé sur les nouvelles publications IEC. Just
Published détaille les nouvelles publications parues. Si vous désirez nous donner des commentaires sur cette
Disponible en ligne et aussi une fois par mois par email. publication ou si vous avez des questions contactez-nous:
csc@iec.ch.
IEC 61169-53 ®
Edition 1.0 2015-09
INTERNATIONAL
STANDARD
NORME
INTERNATIONALE
colour
inside
Radio-frequency connectors –
Part 53: Sectional specification for RF coaxial connectors with inner diameter of
outer conductor 16 mm with screw lock – Characteristic impedance 50 Ω (Type
S7-16)
Connecteurs pour fréquences radioélectriques –
Partie 53: Spécification intermédiaire relative aux connecteurs coaxiaux pour
fréquences radioélectriques avec diamètre intérieur des conducteurs extérieurs
de 16 mm à verrouillage à vis – Impédance caractéristique 50 Ω (Type S7-16)
INTERNATIONAL
ELECTROTECHNICAL
COMMISSION
COMMISSION
ELECTROTECHNIQUE
INTERNATIONALE
ICS 33.120.30 ISBN 978-2-8322-2878-4
– 2 – IEC 61169-53:2015 © IEC 2015
CONTENTS
FOREWORD . 4
1 Scope . 6
2 Normative references . 6
3 Mating face and gauge information . 6
3.1 Dimensions – General connectors – Grade 2 . 6
3.1.1 Connector with pin-centre contact . 6
3.1.2 Connector with socket centre contact . 7
3.2 Gauges . 8
3.2.1 Gauge pin for socket-centre contact . 8
3.2.2 Test procedure . 9
3.3 Dimensions – Standard test connectors – Grade 0 . 9
3.3.1 Connector with pin-centre contact . 9
3.3.2 Standard test connector with socket-centre contact . 10
4 Quality assessment procedures . 12
4.1 General . 12
4.2 Ratings and characteristics (see Clause 5 of IEC 61169-1:2013) . 12
4.3 Test schedule and inspection requirements. 14
4.3.1 Acceptance tests . 14
4.3.2 Periodic tests . 14
4.4 Procedures for the quality conformance . 15
4.4.1 Quality conformance inspection . 15
4.4.2 Qualification approval and its maintenance . 16
5 Instructions for preparation of detail specifications . 16
5.1 General . 16
5.2 Identification of the component . 16
5.3 Performances . 16
5.4 Marking, ordering information and related matters . 16
5.5 Selection of tests, test conditions and severities . 16
5.6 Blank detail specification pro-forma for type S7-16 connector . 17
6 Marking . 21
6.1 Marking of component . 21
6.2 Marking and contents of package . 21
Figure 1 – Connector with pin-centre contact (for dimensions, see Table 1) . 7
Figure 2 – Connector with socket-centre contact (for dimensions, see Table 2). 8
Figure 3 – Gauge pin for socket-centre contact (for dimensions, see Table 3) . 9
Figure 4 – Connector with pin-centre contact (for dimensions, see Table 4) . 10
Figure 5 – Connector with socket-centre contact (for dimensions, see Table 5). 11
Table 1 – Dimensions of connector with pin-centre contact . 7
Table 2 – Dimensions of connector with socket centre contact . 8
Table 3 – Dimensions of gauge pin for socket-centre contact . 9
Table 4 – Dimensions of connector with pin-centre contact . 10
Table 5 – Dimensions of connector with socket-centre contact . 11
Table 6 – Rating and characteristics . 12
Table 7 – Acceptance tests . 14
Table 8 – Periodic tests . 15
– 4 – IEC 61169-53:2015 © IEC 2015
INTERNATIONAL ELECTROTECHNICAL COMMISSION
____________
RADIO-FREQUENCY CONNECTORS –
Part 53: Sectional specification for RF coaxial connectors
with inner diameter of outer conductor 16 mm with screw lock –
Characteristic impedance 50 Ω (Type S7-16)
FOREWORD
1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of IEC is to promote
international co-operation on all questions concerning standardization in the electrical and electronic fields. To
this end and in addition to other activities, IEC publishes International Standards, Technical Specifications,
Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC
Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested
in the subject dealt with may participate in this preparatory work. International, governmental and non-
governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely
with the International Organization for Standardization (ISO) in accordance with conditions determined by
agreement between the two organizations.
2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international
consensus of opinion on the relevant subjects since each technical committee has representation from all
interested IEC National Committees.
3) IEC Publications have the form of recommendations for international use and are accepted by IEC National
Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC
Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any
misinterpretation by any end user.
4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications
transparently to the maximum extent possible in their national and regional publications. Any divergence
between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in
the latter.
5) IEC itself does not provide any attestation of conformity. Independent certification bodies provide conformity
assessment services and, in some areas, access to IEC marks of conformity. IEC is not responsible for any
services carried out by independent certification bodies.
6) All users should ensure that they have the latest edition of this publication.
7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and
members of its technical committees and IEC National Committees for any personal injury, property damage or
other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and
expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC
Publications.
8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is
indispensable for the correct application of this publication.
9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of
patent rights. IEC shall not be held responsible for identifying any or all such patent rights.
International Standard IEC 61169-53 has been prepared by subcommittee 46F: RF and
microwave passive components, of IEC technical committee 46: Cables, wires, waveguides,
R.F. connectors, R.F. and microwave passive components and accessories.
The text of this standard is based on the following documents:
FDIS Report on voting
46F/309/CDV 46F/321/RVC
Full information on the voting for the approval of this standard can be found in the report on
voting indicated in the above table.
This publication has been drafted in accordance with the ISO/IEC Directives, Part 2.
A list of all parts of the IEC 61169 series, under the general title: Radio-frequency connectors,
can be found on the IEC website.
The committee has decided that the contents of this publication will remain unchanged until
the stability date indicated on the IEC website under "http://webstore.iec.ch" in the data
related to the specific publication. At this date, the publication will be
• reconfirmed,
• withdrawn,
• replaced by a revised edition, or
• amended.
IMPORTANT – The 'colour inside' logo on the cover page of this publication indicates
that it contains colours which are considered to be useful for the correct
understanding of its contents. Users should therefore print this document using a
colour printer.
– 6 – IEC 61169-53:2015 © IEC 2015
RADIO-FREQUENCY CONNECTORS –
Part 53: Sectional specification for RF coaxial connectors
with inner diameter of outer conductor 16 mm with screw lock –
Characteristic impedance 50 Ω (Type S7-16)
1 Scope
This part of IEC 61169, which is a sectional specification (SS), provides information and rules
for the preparation of detail specifications (DS) for RF coaxial connectors with threaded
coupling, typically for use in 50 Ω cable networks (Type S7-16).
It prescribes mating face dimensions for general purpose connectors – grade 2, dimensional
details of standard test connectors-grade 0, gauging information and tests selected from
IEC 61169-1, applicable to all detail specifications relating to series 4.1-9.5 RF connectors.
This specification indicates recommended performance characteristics to be considered when
writing a detail specification and it covers test schedules and inspection requirements for
assessment levels M and H.
The S7-16 series RF coaxial connectors with nominal impedance 50 Ω are threaded coupling
units which are used with all kinds of RF cables and microstrips in microwave transmission
system. And the working frequency is up to 7,5 GHz.
NOTE Metric dimension are original dimensions. All undimensioned pictorial configurations are for reference
purpose only.
2 Normative references
The following documents, in whole or in part, are normatively referenced in this document and
are indispensable for its application. For dated references, only the edition cited applies. For
undated references, the latest edition of the referenced document (including any
amendments) applies.
IEC 61169-1:2013, Radio frequency connectors – Part 1: Generic specification – General
requirements and measuring methods
IEC 62037-3 (all parts), Passive RF and microwave devices, intermodulation level
measurement
3 Mating face and gauge information
3.1 Dimensions – General connectors – Grade 2
3.1.1 Connector with pin-centre contact
The mating face of connector with pin-centre contact is shown in Figure 1 and its dimensions
are shown in Table 1.
f
135°
r
k
h
i
Note 3
j
s
IEC
The tolerance on this dimension is determined by the tolerance of characteristic impedance.
The design of this dimension should meet sealing performance at the same time the electrical requirements.
Mechanical and electrical reference plane
Figure 1 – Connector with pin-centre contact (for dimensions, see Table 1)
Table 1 – Dimensions of connector with pin-centre contact
mm
Reference Additional notes
Min. Max.
a M22×1
b 17,87 18,03
c 4,80 4,86
d 7 (nominal) 1
e 16,02 °16,08
f 1,00 1,50
h 1,80 2,20
i 4,20 4,50
j 5,20 5,50
s 7,80 – 2
k 0,00 1,00
l 22,05 22,35
m – 3,70
r 0,12 0,30
3.1.2 Connector with socket centre contact
The mating face of connector with socket centre contact is shown in Figure 2 and its
dimensions are shown in Table 2.
∅l
a
∅b
∅c
∅m
∅d
∅e
– 8 – IEC 61169-53:2015 © IEC 2015
Detail I
p
q
Note 4
s I
r
r
t
0,6 × 45°
Note 5
m
IEC
The design of this dimension should meet gauge test of 3.2.1 and reflection factor requirement.
The tolerance on this dimension is determined by the tolerance of characteristic impedance.
Slot design optional. Contact to be closed to meet electrical and mechanical request.
Root cut.
Mechanical and electrical reference plane
Figure 2 – Connector with socket-centre contact (for dimensions, see Table 2)
Table 2 – Dimensions of connector with socket centre contact
mm
Reference Additional notes
Min. Max.
a M22×1
c – – 1
d 7 (nominal) 2
e 16,02 16,08
n 18,05 18,13
p 9,50 –
q 7,50 –
s 6,70 7,00
t 4,90 5,20
m 5,00 –
z – – 3
r 0,20 0,35
0,20 0,35
r
3.2 Gauges
3.2.1 Gauge pin for socket-centre contact
The gauge pin for socket-centre contact is shown in Figure 3 and its dimensions are shown in
Table 3.
z
∅c
∅d
∅e
∅n
a
30°
R 0,5
∅a
IEC
Figure 3 – Gauge pin for socket-centre contact (for dimensions, see Table 3)
Table 3 – Dimensions of gauge pin for socket-centre contact
Gauge A Gauge B
(For sizing purpose) (For measurement of retention force)
+5
Mass of gauge:1 000 g
Ref.
mm mm
Min. Max. Min. Max.
a 4,91 4,92 4,81 4,82
b 2,00 3,00 2,00 3,00
c 4,50 5,00 4,50 5,00
Material: steel, 0,4 µm maximum finish.
3.2.2 Test procedure
a) Sizing test
The gauge A shall be inserted into the centre contact for three times with a minimum
distance of 2 mm. This is a sizing operation.
b) Withdrawal test
After sizing, the gauge B shall be inserted into socket centre contact. The force to
withdraw gauge B shall be 10 N to 20 N.
3.3 Dimensions – Standard test connectors – Grade 0
3.3.1 Connector with pin-centre contact
Interface of connector with pin-centre contact is shown in Figure 4, dimensions are shown in
Table 4.
NOTE The standard test connector with the tolerances specified in 3.3.1and 3.3.2 guarantees an accuracy of
characteristic impedance of ±0,075 Ω. It is used to carry out the reflection coefficient measurement according to
9.2.1 of IEC 61169-1:2013.
b
c
– 10 – IEC 61169-53:2015 © IEC 2015
f
135°
A
∅0,05
B
∅0,03
B A
r
k
h
Note 2 i
j
s
A
0,015
IEC
The design of this dimension and sealing performance at the same time meet the electrical requirements.
Mechanical and electrical reference plane.
Figure 4 – Connector with pin-centre contact (for dimensions, see Table 4)
Table 4 – Dimensions of connector with pin-centre contact
mm
Reference Additional notes
Min. Max.
a
M22×1
b 17,870 18,030
c 4,800 4,860
d 6,971 6,981
e 16,050 16,070
f 1,000 1,500
h 1,800 2,200
i 4,200 4,500
j 5,200 5,230
s 7,800 – 1
k 0,000 1,000
l 22,050 22,350
m – 3,500
r 0,120 0,300
3.3.2 Standard test connector with socket-centre contact
The mating face of standard test connector with socket-centre contact is shown in Figure 5
and its dimensions are shown in Table 5.
∅l
a
∅b
∅c
∅m
∅d
∅e
Detail I
p
q
A
∅0,05
Note 4
s
I
A
∅0,03
u
r
1 B
∅0,03
x
A
45°
0,6 × 45°
Note 5
y
t r
0,015 A
B
m
Details of socket-centre contact
IEC
When pin gauge Ø 4,850 mm min. Ø 4,860 mm max. is inserted to 2 mm depth.
The design of this dimension should meet requirement of dimension “v”’.
Slot design optional. Contact to be closed to meet electrical and mechanical request.
Root cut.
Mechanical and electrical reference plane.
Figure 5 – Connector with socket-centre contact (for dimensions, see Table 5)
Table 5 – Dimensions of connector with socket-centre contact
mm
Reference Notes
Min. Max.
a M22×1
d 6,971 6,981
d1 5,000 5,500
e 16,050 16,070
n 18,080 18,100
p 9,500 –
q 7,500 –
s 6,700 7,000
t 5,170 5,200
m 5,000 –
u 7,200 7,400
v 6,997 7,003 1
w – – 2
z 0,200 0,300 3
r 0,20 0,35
r 0,20 0,35
∅e
∅n
a
∅d
∅d
z
∅w
∅v
– 12 – IEC 61169-53:2015 © IEC 2015
4 Quality assessment procedures
4.1 General
Subclauses 4.1 to 4.4 provide recommended ratings, performance and test conditions to be
considered when writing a detail specification (DS). They also provide an appropriate
schedule of tests with minimum levels of conformance inspection sampling, together with the
pro forma blank detail specification (BDS) and instructions for the preparation of a detail
specification.
4.2 Ratings and characteristics (see Clause 5 of IEC 61169-1:2013)
The values indicated below are recommended for S7-16 series RF connectors and are given
for the writer of the detail specification. They are applicable for the condition when the
connectors are fully mated.
Certain tests will usually not be required. When these tests are required, appropriate values
shall be entered in the detail specification at the discretion of the specification writer.
Rating and characteristics are given in Table 6.
Table 6 – Rating and characteristics
Ratings and Test method Value Remarks, deviation from
characteristics IEC 61169-1:2013 standard test method
Subclause
Electrical
Nominal impedance 50 Ω
Frequency range DC to 7,5 GHz
a
9.2.1 For interface only
Return loss
Straight styles ≥20 dB (DC to 7,5 GHZ)
Right angle styles See DS
For flexible cable See DS
Component mounting style See DS
Solder bucket and PCB See DS
mounting style
Insertion loss Na
a 9.2.2 500 W at 2 GHz 25 °C VSWR = 1 at sea
Power rating
level
2GHz peak power 5 KW
Duty ratio 10 %
b
9.2.3
Centre contact resistance
initial < 0,4 mΩ
after tests
< 0,8 mΩ
b
9.2.3
Outer contact continuity
initial
≤ 1,5 mΩ
after tests
≤ 1,9 mΩ
Insulation resistance 9.2.5
initial
≥ 10 GΩ
after conditioning ≥ 100 MΩ
c, d
Proof voltage
Sea level 9.2.6 3 000 Vrms
At 4,4 Kpa 350 Vrms
e
9.2.7
Screening effectiveness
Ratings and Test method Value Remarks, deviation from
characteristics IEC 61169-1:2013 standard test method
Subclause
0,5 GHz to 1 GHz Applied torque 25 Nm
>110 dB at 1 GHz
Zt = 0,02 mΩ
Intermodulation level IEC 62037 –155 dBc Testing power 20 W
Discharge test (Corona effect) 9.2.8 2 800 V
at sea level
Mechanical
Gauge retention force 9.3.4
(resilient contact)
Centre contact 10 N to 20 N
Outer contact Na
f
9.3.5
Centre contact captivation
axial force
≥ 200 N
torque See DS
Engagement and separation
axial force
engagement Typical
≤ 28 N
separation ≤ 28 N Typical
Coupling moment
Coupling nut friction
Coupling torque
≤ 30 Nm
Proof torque
Effectiveness of cable fixing
against
– cable rotation 9.3.7 See DS
– cable pulling 9.3.8 See DS
See DS
– cable bending 9.3.9 300 N climatic category A Bending number 10
Bending angle 90°
150 N climatic category B
– cable torsion 9.3.10 5 Nm climatic category A
2,5 Nm climatic category B
Tensile strength of coupling 9.3.11
≥ 445 N
mechanism
Bump 9.3.13 See DS
Vibration 9.3.3 10 g acceleration
1 000 m/s
(10 Hz to 500 Hz)
Shock 9.3.14 50 g acceleration
500 m/s 1/2sine wave
11 ms
Endurance
Mechanical endurance 9.3.15 500 operations
High temperature 9.4.5 1 000 h at 125 °C
g
endurance
Environmental
Climatic category 40/85/21 A
55/125/21 B
Salt mist 9.4.10 48 h spray
– 14 – IEC 61169-53:2015 © IEC 2015
Ratings and Test method Value Remarks, deviation from
characteristics IEC 61169-1:2013 standard test method
Subclause
Sealing 9.4.7 100 kPa to 110 kPa
1 cm /h max
differential pressure
Water immersion 9.4.9 See DS
a
Characteristics indicated are those that can be applied to basic connector. Intrinsic limitations of the cable may
diminish the performance of the assembly and reference should always be made to the actual values given in
the detail specification.
b
Values for a single pair of connectors.
c
Voltages are r.m.s. values of a.c. at 40 Hz to 65 Hz, unless otherwise specified.
d
Values are depending also of the cable type.
e
Applicable in fully mated position. Depending of cable type values for a single pair of connector.
f
Maximum displacement of 0,25 mm in each direction.
g
Upper temperature limit can be restricted by the cable characteristics. Reference should be made to the
relevant cable specification.
4.3 Test schedule and inspection requirements
4.3.1 Acceptance tests
There are no group C tests for levels H and M.
Table 7 describes the acceptance tests to be performed.
4.3.2 Periodic tests
Table 8 describes the periodic tests to be performed.
Table 7 – Acceptance tests
Assessment level M (higher) Assessment level H (lower)
IEC 61169-
1:2013
– Test IL AQL Period Test IL AQL Period
required required
Subclause
% %
Group A1
Visual inspection
9.1.1 a II 1 a S3 1,5
Group B1
Outline dimension
9.1.2 a S4 0,4 a S3 4,0
Mechanical 9.1.2.2 a II 1 a S3 1,5
compatibility
Engagement and
9.3.6 a S4 0,4 a S3 1,5
separation
Gauge retention
9.3.4 ia II 1 ia S3 1,5
(resilient contacts)
Sealing
non hermetic
9.4.7 ia II 0,65 ia S3 1
hermetic
9.4.8 ia II 0,015 ia S3 0,025
Voltage proof
9.2.6 a II 0,4 a II 4,0
Solderability (d)
9.3.2.2 ia S4 0,4 ia S3 4,0
Insulation resistance
9.2.5 a S4 0,4 a S3 4,0
For the symbols, abbreviations and procedures, see the end of Table 8.
Lot by Lot
Lot by Lot
Table 8 – Periodic tests
IEC 61169-1:2013 Assessment level M (higher) Assessment level H
Subclause (lower)
Group D1 (d) 6 1 3 years 3 1 3 years
Solderability connector
9.3.2.2 ia ia
assemblies
Resistance to soldering heat 9.3.2.3 ia ia
Mechanical tests on cable
fixing
cable rotation (nutation) 9.3.7 na na
cable pulling 9.3.8 ia ia
cable bending 9.3.9 ia ia
cable torsion 9.3.10 ia ia
Group D2 (d) 6 1 3 years 3 1 3 years
Contact resistance, outer
conductor and screen
9.2.3 a a
continuity centre conductor
continuity
Vibration 9.3.3 a
Damp heat, steady state 9.4.3 a a
Group D3 (d) 1 1 3 years 1* 1 3 years
Dimensions piece-parts and
9.1.2 a a
materials
Group D4 (d) 6 1 3 years 3 1 3 years
Mechanical endurance 9.3.15 a a
High temperature endurance 9.4.5 a a
Discharge test 9.2.8
Climatic conditioning 9.4 na na
Group D5 (d) 6 1 3 years 3 1 3 years
Return loss 9.2.1 a a
Screening effectiveness 9.2.7 a a
Water immersion 9.4.9 ia ia
Group D6 (d) 6 1 3 years 3 1 3 years
Contact captivation 9.3.5 a a
Rapid change of
9.4.4 na na
temperature
Climatic sequence 9.4.2 a a
1§ 3 years 1§ 3 years
Group D7 (d)
Salt mist 9.4.10 a
a suggested as applicable
ia test suggested (if technically applicable)
na not applicable
IL inspection level
AQL acceptable quality level
* one set of piece-parts each style and variant, unless using common piece parts
# for quality conformance , a total of two failures only permitted for level H and 1 failure only for level M
from groups D1 to D7
§ Group D7 – number of pairs for each solvent
(d) destructive tests – specimens shall not be returned to stock
4.4 Procedures for the quality conformance
4.4.1 Quality conformance inspection
This shall consist of test group A1 and B1 on a lot-by-lot basis.
– 16 – IEC 61169-53:2015 © IEC 2015
4.4.2 Qualification approval and its maintenance
This still consists of three consecutive lots passing test groups A1 and B1 followed by
selection of specimens from the lots as appropriate. These specimens shall successfully pass
the specified periodic D tests.
5 Instructions for preparation of detail specifications
5.1 General
Detail specifications (DS) writers shall use the appropriate BDS pro-forma. The following
pages comprise the pro-forma BDS dedicated for use with type 50 Ω type S7-16 connectors.
As such, it will already have entered on it information relating to
a) the basic specification number applicable to all the detail specification covering connector
styles of the type covered by the sectional specification,
b) the connector series designation.
The specification writer should enter the details relating to the connector style/variant(s) to be
covered as indicated. The numbers in brackets on the BDS correspond to the following
indications which shall be given.
5.2 Identification of the component
(1) Enter the following details:
– style: the style designation of the connector including type of fixing and sealing if
applicable;
– attachment: by deletion of the inapplicable options of cable/wire: given for centre and
outer conductors;
– special features and markings: as applicable;
– series designation: in bold characters/digits approximately 15 mm high;
(2) Enter details of assessment level and the climatic category.
(3) A reproduction of the outline drawing and details of the panel piercing (if applicable). It
shall provide the maximum envelope dimensions, also the position of the reference plane
and, in the case of a fixed connector, the position of the mouting plane(s) relative to the
front face of the connector.
(4) Any maximum panel thickness limitations for fixed connectors shall be stated.
(5) Particulars of all variants covered by the DS. As appropriate, the information shall include:
– cable types (or sizes) applicable to each variant;
– alternative plated or protective finishes;
– details of alternative mounting flanges having either tapped or plain mounting holes;
– details of alternative solder spills or solder buckets including, when applicable, those
for use with microwave integrated circuit (MIC) components.
5.3 Performances
(6) Performance data listing the most important characteristics of the connectors in
accordance with the requirements of the relevant sectional specification. Deviation from
the minimum requirements shall be clearly indicated. Non-applicable parameters shall be
marked "na".
5.4 Marking, ordering information and related matters
(7) Insert marking and ordering information as appropriate, together with details or related
documents and any invoked structural similarity.
5.5 Selection of tests, test conditions and severities
(8) "na" shall be used to indicated non-applicable tests. All tests marked "a" by the detail
specification writer shall be mandatory.
When using the normal procedure with a dedicated BDS, the letter "a" − for applicable − shall
be entered in the 'test required' column against each of the tests indicated as being
mandatory in the test schedule of the relevant sectional specification. Any additional tests
required at the discretion of the specification writer shall also be indicated by an "a".
The specification writer shall also indicate, when necessary, details of deviations from the
standard test method and test conditions, including any relevant deviations given in the test
schedule of the sectional specification.
5.6 Blank detail specification pro-forma for type S7-16 connector
The following pages contain the complete BDS pro-forma.
(1) Page 1 of
(2)
ELECTRONIC COMPONENT OF ASSESSED (3) .
QUALITY IN ACCORDANCE WITH GENERIC
(4) .
SPECIFICATION IEC 61169-1 NATIONAL
REFERENCE
(5) Detail specification for radio frequency coaxial connector of Type
assessed quality
Style Special features and markings
Method of cable/wire+ attachment centre conductor – solder/crimp+
outer conductor – solder/clamp/crimp +
+ delete as appropriate
(6) Assessment level. Characteristic impedance Climatic category.40/85./21./
50 Ω
(7) Outline and maximum dimensions Panel piercing and mounting details
(8) Variants
Variant No. Description IEC 61196
of variant
. . . . . .
. . . . . .
Information about manufacturers who have components qualified under the IECQ Conformity Assessment
System is available through the IECQ on-line certificate system.
– 18 – IEC 61169-53:2015 © IEC 2015
(9) Performance (including limiting conditions of use)
Ratings and Variant No. IEC 61169-1:2013 Value Remarks,
characteristics Designation Subclause including any
deviations from
standard test
methods
Electrical
Nominal impedance
50 Ω
Frequency range 9.2.1 0 GHz to 7,5 GHz Measurement
frequency range
Return loss
GHz
GHz
GHz
Centre contact 9.2.3 ≤ mΩ Initial
resistance
After conditioning
≤ mΩ
Centre conductor 9.2.3 Resistance change
≤ mΩ
continuity due to conditioning
≤ mΩ
≤ mΩ
≤ mΩ
Outer contact 9.2.3 Initial
≤ mΩ
continuity
≤ mΩ After conditioning
Insulation resistance 9.2.5 Initial
≥ GΩ
After conditioning
≥ GΩ
+ Proof voltage at 9.2.6 kV 86 kPa to 106 kPa
sea level
kV
kV
kV
9.2.6 kV kPa (if not
+ Proof voltage at
4,4 kPa 4,4 kPa)
kV
kV
kV
Screening 9.2.7 dB at
Z ≤. mΩ
t
effectiveness GHz
Discharge test 9.2.8 ≥ V Extinction voltage
(corona) at sea level
≥ V
≥ V
≥ V
ADDITIONAL
ELECTRICAL
CHARACTERISTICS
Intermodulation level IEC 62037 dBc at Testing 20 W
GHz
+ Voltage values are r.m.s. values at 50 Hz to 60 Hz, unless otherwise specified.
Ratings and IEC 61169-1:2013 Value Remarks, including
characteristics Subclause any deviations from
standard test
methods
Mechanical
Soldering 9.3.2
– bit size
9.3.4
Gauge retention
resilient contacts
– inner contact N
See Figure 7 and
Table 3
– outer contact N
See Figure 8 and
Table 4
9.3.5
Centre contact
captivation
– axial force N
– permitted mm
displacement each
direction
– torque Nm
9.3.6 Achievable by hand
Engagement and
separation
– axial force
Strength of coupling 9.3.11 N
mechanism
Effectiveness of Rotations
cable fixing against
– cable rotation 9.3.7
– cable pulling 9.3.8 Point of application
and duration
N mm s
N mm s
N mm s
N mm s
– cable bending 9.3.9
Length of cable and
mass
cycles mm
cycles mm
cycles mm
cycles mm
– cable torsion 9.3.10 Duration of applied
torque
Nm s
Nm s
Nm s
Nm s
Bending moment 9.3.12 Nm Relative to reference
plane
Bumps total 9.3.13 ( g
m/s
n
to Hz
acceleration)
Vibration 9.3.3 ( g
m/s
n
to Hz
acceleration)
Shock 9.3.14 ( g
m/s
n
Shape
acceleration)
ms
ADDITIONAL
MECHANICAL
CHARACTERISTICS
– 20 – IEC 61169-53:2015 © IEC 2015
Ratings and IEC 61169-1:2013 Value Remarks including
characteristics Subclause any deviations
from standard test
methods
Environmental
Climatic category
Sealing non- 100 kPa to 110 kPa
hermetically sealed 9.4.7 cm /h pressure differential
connectors
Sealing hermetically 100 kPa to 110 kPa
–5 3
9.4.8 10 bar/cm /h
sealed connectors pressure differential
Water immersion 9.4.9
Salt mist 9.4.10 h Duration of spraying
ADDITIONAL ENVIRONMENTAL CHARACTERISTICS
ENDURANCE
Mechanical 9.3.15 operations
High temperature
h
9.4.5
at °C
ADDITIONAL
ENDURANCE
CHARACTERISTICS
CHEMICAL CONTAMINATION
Resistance to
solvents and
contaminating fluids
9.4.11
to be used.
Applicable fluids
Sulphur dioxide 9.4.12 days
(10) Supplementary information
– Marking of the component: in accordance with 11.1 of IEC 61169-1:2013 in the following order of
procedure
1) Identity of manufacture
2) Manufacturing date code year /week
Component identification variant No./designation Identification
‒ Marking and contents of package: in accordance with 11.2 of IEC 61169-1:2013
1) Information prescribed in 11.1 of IEC 61169-1:2013 detailed above
2) Nominal characteristic impedance Ω
3) Assessment level code letter
4) Any additional marking required
‒ Ordering information:
1) Number of the detail specification/variant code
2) Assessment level code letter
3) Body finish (if more than one listed)
4) Any additional information or special requirements
– Related documents (if not included in IEC 61169-1:2013 or sectional specification):
.
.
‒ Structural similarity in accordance with 10.2.2 of IEC 61169-1:2013
Relevant information on a basic style should be entered as variant 01.
6 Marking
6.1 Marking of component
Each component shall be legibly and durably marked, where space permits and in the
following order of precedence, with:
a) identity code of the manufacturer;
b) manufacturer’s connector identification code or IEC connector designation.
6.2 Marking and contents of package
The package shall be marked with the information prescribed in 6.1 and, in addition, the
following information shall be given:
a) nominal characteristic impedance;
– 22 – IEC 61169-53:2015 © IEC 2015
b) manufacturing date code;
c) any additional marking required by the relevant specification.
When required by the relevant specification, the package shall also include instructions for
assembling the connector(s) and instructions for the use of any special tools or materials, as
necessary.
_____________
– 24 – IEC 61169-53:2015 © IEC 2015
SOMMAIRE
AVANT-PROPOS . 26
1 Domaine d’application . 28
2 Références normatives . 28
3 Informations relatives aux éléments d’accouplement et aux calibres . 28
...