IEC 61753-131-3:2010
(Main)Fibre optic interconnecting devices and passive components - Performance standard - Part 131-3: Single-mode mechanical fibre splice for category U - Uncontrolled environment
- Abstract
IEC 61753-131-3:2010 contains the minimum initial test and measurement requirements and severities which a mechanical fibre splice will satisfy in order to be categorised as meeting the requirements of single-mode fibre splice for use in uncontrolled environments.
- Status
- Replaced
- Publication Date
- 26-Jan-2010
- Technical Committee
- SC 86B - Fibre optic interconnecting devices and passive components
- Current Stage
- DELPUB - Deleted publication - 99 Deleted
- Start Date
- 04-Oct-2021
- Due Date
- 30-Jun-2020
- Completion Date
- 30-Jun-2020
Buy Documents
IEC 61753-131-3:2010 - Fibre optic interconnecting devices and passive components - Performance standard - Part 131-3: Single-mode mechanical fibre splice for category U - Uncontrolled environment Released:1/27/2010
IEC 61753-131-3:2010 - Fibre optic interconnecting devices and passive components - Performance standard - Part 131-3: Single-mode mechanical fibre splice for category U - Uncontrolled environment Released:1/27/2010
Relations
- Effective Date
- 05-Sep-2023
Buy Documents
IEC 61753-131-3:2010 - Fibre optic interconnecting devices and passive components - Performance standard - Part 131-3: Single-mode mechanical fibre splice for category U - Uncontrolled environment Released:1/27/2010
IEC 61753-131-3:2010 - Fibre optic interconnecting devices and passive components - Performance standard - Part 131-3: Single-mode mechanical fibre splice for category U - Uncontrolled environment Released:1/27/2010
Get Certified
Connect with accredited certification bodies for this standard

ANCE
Mexican certification and testing association.

Intertek Slovenia
Intertek testing, inspection, and certification services in Slovenia.

LNE (Laboratoire National de Métrologie et d'Essais)
French national laboratory for metrology and testing.
Sponsored listings
Frequently Asked Questions
IEC 61753-131-3:2010 is a standard published by the International Electrotechnical Commission (IEC). Its full title is "Fibre optic interconnecting devices and passive components - Performance standard - Part 131-3: Single-mode mechanical fibre splice for category U - Uncontrolled environment". This standard covers: IEC 61753-131-3:2010 contains the minimum initial test and measurement requirements and severities which a mechanical fibre splice will satisfy in order to be categorised as meeting the requirements of single-mode fibre splice for use in uncontrolled environments.
IEC 61753-131-3:2010 contains the minimum initial test and measurement requirements and severities which a mechanical fibre splice will satisfy in order to be categorised as meeting the requirements of single-mode fibre splice for use in uncontrolled environments.
IEC 61753-131-3:2010 is classified under the following ICS (International Classification for Standards) categories: 33.180.20 - Fibre optic interconnecting devices. The ICS classification helps identify the subject area and facilitates finding related standards.
IEC 61753-131-3:2010 has the following relationships with other standards: It is inter standard links to IEC 61753-131-03:2021. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
IEC 61753-131-3:2010 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
IEC 61753-131-3 ®
Edition 1.0 2010-01
INTERNATIONAL
STANDARD
Fibre optic interconnecting devices and passive components – Performance
standard –
Part 131-3: Single-mode mechanical fibre splice for category U – Uncontrolled
environment
All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form
or by any means, electronic or mechanical, including photocopying and microfilm, without permission in writing from
either IEC or IEC's member National Committee in the country of the requester.
If you have any questions about IEC copyright or have an enquiry about obtaining additional rights to this publication,
please contact the address below or your local IEC member National Committee for further information.
IEC Central Office
3, rue de Varembé
CH-1211 Geneva 20
Switzerland
Email: inmail@iec.ch
Web: www.iec.ch
About the IEC
The International Electrotechnical Commission (IEC) is the leading global organization that prepares and publishes
International Standards for all electrical, electronic and related technologies.
About IEC publications
The technical content of IEC publications is kept under constant review by the IEC. Please make sure that you have the
latest edition, a corrigenda or an amendment might have been published.
ƒ Catalogue of IEC publications: www.iec.ch/searchpub
The IEC on-line Catalogue enables you to search by a variety of criteria (reference number, text, technical committee,…).
It also gives information on projects, withdrawn and replaced publications.
ƒ IEC Just Published: www.iec.ch/online_news/justpub
Stay up to date on all new IEC publications. Just Published details twice a month all new publications released. Available
on-line and also by email.
ƒ Electropedia: www.electropedia.org
The world's leading online dictionary of electronic and electrical terms containing more than 20 000 terms and definitions
in English and French, with equivalent terms in additional languages. Also known as the International Electrotechnical
Vocabulary online.
ƒ Customer Service Centre: www.iec.ch/webstore/custserv
If you wish to give us your feedback on this publication or need further assistance, please visit the Customer Service
Centre FAQ or contact us:
Email: csc@iec.ch
Tel.: +41 22 919 02 11
Fax: +41 22 919 03 00
IEC 61753-131-3 ®
Edition 1.0 2010-01
INTERNATIONAL
STANDARD
Fibre optic interconnecting devices and passive components – Performance
standard –
Part 131-3: Single-mode mechanical fibre splice for category U – Uncontrolled
environment
INTERNATIONAL
ELECTROTECHNICAL
COMMISSION
PRICE CODE
R
ICS 33.180.20 ISBN 978-2-88910-564-9
– 2 – 61753-131-3 © IEC:2010(E)
CONTENTS
FOREWORD.3
INTRODUCTION.5
1 Scope.6
2 Normative references.6
3 General requirements .7
3.1 Storage, transportation and packaging .7
3.2 Marking and identification .7
3.3 Materials .7
3.4 Test report.8
4 Test.8
4.1 General .8
4.2 Test sample preparation .8
4.3 Test and measurement methods .8
4.4 Pass/fail criteria.9
5 Performance requirements.9
5.1 Sample size, sequencing and grouping .9
5.2 Dimensions .9
5.3 Installation yield requirement .9
5.4 Test details and requirements.9
Annex A (informative) Fibre type .16
Annex B (normative) Sample size and product sourcing requirements.17
Bibliography .18
Table 1 – Test details and requirements .9
Table A.1 – Fibre type characteristics.16
Table B.1 – Sample size per test .17
61753-131-3 © IEC:2010(E) – 3 –
INTERNATIONAL ELECTROTECHNICAL COMMISSION
____________
FIBRE OPTIC INTERCONNECTING
DEVICES AND PASSIVE COMPONENTS –
PERFORMANCE STANDARD –
Part 131-3: Single-mode mechanical fibre splice for category U –
Uncontrolled environment
FOREWORD
1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of IEC is to promote
international co-operation on all questions concerning standardization in the electrical and electronic fields. To
this end and in addition to other activities, IEC publishes International Standards, Technical Specifications,
Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC
Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested
in the subject dealt with may participate in this preparatory work. International, governmental and non-
governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely
with the International Organization for Standardization (ISO) in accordance with conditions determined by
agreement between the two organizations.
2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international
consensus of opinion on the relevant subjects since each technical committee has representation from all
interested IEC National Committees.
3) IEC Publications have the form of recommendations for international use and are accepted by IEC National
Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC
Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any
misinterpretation by any end user.
4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications
transparently to the maximum extent possible in their national and regional publications. Any divergence
between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in
the latter.
5) IEC itself does not provide any attestation of conformity. Independent certification bodies provide conformity
assessment services and, in some areas, access to IEC marks of conformity. IEC is not responsible for any
services carried out by independent certification bodies.
6) All users should ensure that they have the latest edition of this publication.
7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and
members of its technical committees and IEC National Committees for any personal injury, property damage or
other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and
expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC
Publications.
8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is
indispensable for the correct application of this publication.
9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of
patent rights. IEC shall not be held responsible for identifying any or all such patent rights.
International Standard IEC 61753-131-3 had been prepared by subcommittee 86B: Fibre optic
interconnecting devices and passive components of IEC technical committee 86: Fibre optics.
The text of this standard is based on the following documents:
FDIS Report on voting
86B/2945/FDIS 86B/2983/RVD
Full information on the voting for the approval of this standard can be found in the report on
voting indicated in the above table.
This publication has been drafted in accordance with the ISO/IEC Directives, Part 2.
– 4 – 61753-131-3 © IEC:2010(E)
A list of all parts of IEC 61753 series, published under the general title Fibre optic
interconnecting devices and passive components performance standard, can be found on the
IEC website.
Future standards in this series will carry the new general title as cited above. Titles of existing
standards in this series will be updated at the time of the next edition.
The committee has decided that the contents of this publication will remain unchanged until the
maintenance result date indicated on the IEC web site under "http://webstore.iec.ch" in the data
related to the specific publication. At this date, the publication will be
• reconfirmed,
• withdrawn,
• replaced by a revised edition, or
• amended.
A bilingual version of this publication may be issued at a later date.
61753-131-3 © IEC:2010(E) – 5 –
INTRODUCTION
This part of IEC 61753 for mechanical splices defines the requirements for standard optical
performance under a set of specified conditions. The standard contains a series or a set of
tests and measurements with clearly stated conditions, severities and pass/fail criteria. The
series of tests, commonly referred to as an operating service environment or performance
category, is intended to be a basis to prove the product’s ability to satisfy the requirements of a
specific application, market sector or user group.
A product that has been shown to meet all the requirements of this performance standard may
be declared as complying with this performance standard. Products having the same
classification from one manufacturer that satisfy this performance standard, will operate within
the boundaries set by the performance standard. There is no guarantee that products from
different manufacturers, having the same classification and which conform to the same
performance standard, will provide an equivalent level of performance when they are used
together.
Conformance with IEC environmental policy according to IEC Guide 109 and concerning the need
to reduce the impact on the natural environment of fibre management system products during
all phases of their life – from acquiring materials to manufacturing, distribution, use, and end-
of-life treatment (i.e. re-use, recycling (recovery and disposal)) are not part of this standard,
but will be covered in the generic specification.
Conformance to a performance standard demonstrates that a product has passed a design
verification test. It is not a guarantee of lifetime assured performance or reliability. Reliability
testing are the subject of a separate test schedule, where the tests and severities selected are
such that they are truly representative of the requirements of this reliability test programme.
Consistency of manufacture should be maintained using a recognised Quality Assurance
programme whilst the reliability of product should be evaluated using the procedures
recommended in IEC 62005 series.
Tests and measurements are selected from the IEC 61300 series.
– 6 – 61753-131-3 © IEC:2010(E)
FIBRE OPTIC INTERCONNECTING
DEVICES AND PASSIVE COMPONENTS –
PERFORMANCE STANDARD –
Part 131-3: Single-mode mechanical fibre splice for category U –
Uncontrolled environment
1 Scope
This part of IEC 61753 contains the minimum initial test and measurement requirements and
severities which a mechanical fibre splice will satisfy in order to be categorised as meeting the
requirements of single-mode fibre splice for use in uncontrolled environments.
2 Normative references
The following referenced documents are indispensable for the application of this document. For
dated references, only the edition cited applies. For undated references, the latest edition of
the referenced document (including any amendments) applies.
IEC 60721-3-2, Classification of environmental conditions – Part 3: Classification of groups of
environmental parameters and their severities – Section 2: Transportation
IEC 61073-1, Fibre optic interconnecting devices and passive components – Mechanical splices
and fusion splice protectors for optical fibres and cables – Part 1: Generic specification
IEC 61300-1, Fibre optic interconnecting devices and passive components – Basic test and
measurement procedures – Part 1: General and guidance
IEC 61300-2-1, Fibre optic interconnecting devices and passive components – Basic test and
measurement procedures – Part 2-1: Tests – Vibration (sinusoidal)
IEC 61300-2-4, Fibre optic interconnecting devices and passive components – Basic test and
measurement procedures – Part 2-4: Tests – Fibre/cable retention
IEC 61300-2-5, Fibre optic interconnecting devices and passive components – Basic test and
measurement procedures – Part 2-5: Tests – Torsion
IEC 61300-2-9, Fibre optic interconnecting devices and passive components – Basic test and
measurement procedures – Part 2-9:Tests – Shock
IEC 61300-2-17, Fibre optic interconnecting devices and passive components – Basic test and
measurement procedures – Part 2-17: Tests – Cold
IEC 61300-2-18, Fibre optic interconnecting devices and passive components – Basic test and
measurement procedures – Part 2-18: Tests – Dry heat – High temperature endurance
IEC 61300-2-22, Fibre optic interconnecting devices and passive components – Basic test and
measurement procedures – Part 2-22: Tests – Change of temperature
IEC 61300-2-26, Fibre optic interconnecting devices and passive components – Basic test and
measurement procedures – Part 2-26: Tests – Salt mist
61753-131-3 © IEC:2010(E) – 7 –
IEC 61300-2-27, Fibre optic interconnecting devices and passive components – Basic test and
measurement procedures – Part 2-27: Tests – Dust – Laminar flow
IEC 61300-2-33, Fibre optic interconnecting devices and passive components – Basic test and
measurement procedures – Part 2-33: Tests – Assembly and disassembly of fibre optic
closures
IEC 61300-3-3, Fibre optic interconnecting devices and passive components – Basic test and
measurement procedures – Part 3-3: Examinations and measurements – Active monitoring of
changes in attenuation and return loss
IEC 61300-3-4, Fibre optic interconnecting devices and passive components – Basic test and
measurement procedures – Part 2-26: Tests – Salt mist
IEC 61300-3-6, Fibre optic interconnecting devices and passive components – Basic test and
measurement procedures – Part 3-6: Examinations and measurements – Return Loss
IEC 61300-3-7, Fibre optic interconnecting devices and passive components – Basic test and
measurement procedures – Part 3-7: Examinations and measurements – Wavelength
dependence of attenuation and return loss of single mode components
IEC 61300-3-28, Fibre optic interconnecting devices and passive components – Basic test and
measurement procedures – Part 3-8: Examinations and measurements – Transient loss
3 General requirements
3.1 Storage, transportation and packaging
The classes of environmental conditions and their severities to which the mechanical splice
may be exposed during transportation are defined in IEC 60721-3-2. Normal transportation
time is considered to be 30 days or less.
The product, in its original packaging, shall be suitable for normal public or commercial
transportation and storage in weather protected non-temperature controlled storage
environments.
3.2 Marking and identification
Marking of the packaging of the mechanical splice shall be according to IEC 61073-1.
Product marking and identification shall survive the storage and transportation.
Each test sample should contain the following information at the minimum:
– manufacturer’s identification mark or logo;
– product designation, model or type;
– one of the following: lot number, batch number, date (at least month and year) of
production or serial number;
– expiry date (at least year) if the product contains components with a limited shelf life.
3.3 Materials
For all applicable materials, a Material Safety Data Sheet must be made available upon request.
– 8 – 61753-131-3 © IEC:2010(E)
The materials of the mechanical splice shall be compatible with the other
...
IEC 61753-131-3 ®
Edition 1.0 2010-01
INTERNATIONAL
STANDARD
NORME
INTERNATIONALE
Fibre optic interconnecting devices and passive components – Performance
standard –
Part 131-3: Single-mode mechanical fibre splice for category U – Uncontrolled
environment
Dispositifs d'interconnexion et composants passifs à fibres optiques – Norme
de performance –
Partie 131-3: Epissure mécanique de fibres unimodales pour catégorie U –
Environnement non contrôlé
All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form or by
any means, electronic or mechanical, including photocopying and microfilm, without permission in writing from either IEC or
IEC's member National Committee in the country of the requester.
If you have any questions about IEC copyright or have an enquiry about obtaining additional rights to this publication,
please contact the address below or your local IEC member National Committee for further information.
Droits de reproduction réservés. Sauf indication contraire, aucune partie de cette publication ne peut être reproduite
ni utilisée sous quelque forme que ce soit et par aucun procédé, électronique ou mécanique, y compris la photocopie
et les microfilms, sans l'accord écrit de la CEI ou du Comité national de la CEI du pays du demandeur.
Si vous avez des questions sur le copyright de la CEI ou si vous désirez obtenir des droits supplémentaires sur cette
publication, utilisez les coordonnées ci-après ou contactez le Comité national de la CEI de votre pays de résidence.
IEC Central Office
3, rue de Varembé
CH-1211 Geneva 20
Switzerland
Email: inmail@iec.ch
Web: www.iec.ch
About the IEC
The International Electrotechnical Commission (IEC) is the leading global organization that prepares and publishes
International Standards for all electrical, electronic and related technologies.
About IEC publications
The technical content of IEC publications is kept under constant review by the IEC. Please make sure that you have the
latest edition, a corrigenda or an amendment might have been published.
ƒ Catalogue of IEC publications: www.iec.ch/searchpub
The IEC on-line Catalogue enables you to search by a variety of criteria (reference number, text, technical committee,…).
It also gives information on projects, withdrawn and replaced publications.
ƒ IEC Just Published: www.iec.ch/online_news/justpub
Stay up to date on all new IEC publications. Just Published details twice a month all new publications released. Available
on-line and also by email.
ƒ Electropedia: www.electropedia.org
The world's leading online dictionary of electronic and electrical terms containing more than 20 000 terms and definitions
in English and French, with equivalent terms in additional languages. Also known as the International Electrotechnical
Vocabulary online.
ƒ Customer Service Centre: www.iec.ch/webstore/custserv
If you wish to give us your feedback on this publication or need further assistance, please visit the Customer Service
Centre FAQ or contact us:
Email: csc@iec.ch
Tel.: +41 22 919 02 11
Fax: +41 22 919 03 00
A propos de la CEI
La Commission Electrotechnique Internationale (CEI) est la première organisation mondiale qui élabore et publie des
normes internationales pour tout ce qui a trait à l'électricité, à l'électronique et aux technologies apparentées.
A propos des publications CEI
Le contenu technique des publications de la CEI est constamment revu. Veuillez vous assurer que vous possédez
l’édition la plus récente, un corrigendum ou amendement peut avoir été publié.
ƒ Catalogue des publications de la CEI: www.iec.ch/searchpub/cur_fut-f.htm
Le Catalogue en-ligne de la CEI vous permet d’effectuer des recherches en utilisant différents critères (numéro de référence,
texte, comité d’études,…). Il donne aussi des informations sur les projets et les publications retirées ou remplacées.
ƒ Just Published CEI: www.iec.ch/online_news/justpub
Restez informé sur les nouvelles publications de la CEI. Just Published détaille deux fois par mois les nouvelles
publications parues. Disponible en-ligne et aussi par email.
ƒ Electropedia: www.electropedia.org
Le premier dictionnaire en ligne au monde de termes électroniques et électriques. Il contient plus de 20 000 termes et
définitions en anglais et en français, ainsi que les termes équivalents dans les langues additionnelles. Egalement appelé
Vocabulaire Electrotechnique International en ligne.
ƒ Service Clients: www.iec.ch/webstore/custserv/custserv_entry-f.htm
Si vous désirez nous donner des commentaires sur cette publication ou si vous avez des questions, visitez le FAQ du
Service clients ou contactez-nous:
Email: csc@iec.ch
Tél.: +41 22 919 02 11
Fax: +41 22 919 03 00
IEC 61753-131-3 ®
Edition 1.0 2010-01
INTERNATIONAL
STANDARD
NORME
INTERNATIONALE
Fibre optic interconnecting devices and passive components – Performance
standard –
Part 131-3: Single-mode mechanical fibre splice for category U – Uncontrolled
environment
Dispositifs d'interconnexion et composants passifs à fibres optiques – Norme
de performance –
Partie 131-3: Epissure mécanique de fibres unimodales pour catégorie U –
Environnement non contrôlé
INTERNATIONAL
ELECTROTECHNICAL
COMMISSION
COMMISSION
ELECTROTECHNIQUE
PRICE CODE
INTERNATIONALE
R
CODE PRIX
ICS 33.180.20 ISBN 978-2-88912-047-5
– 2 – 61753-131-3 © IEC:2010
CONTENTS
FOREWORD.3
INTRODUCTION.5
1 Scope.6
2 Normative references.6
3 General requirements .7
3.1 Storage, transportation and packaging .7
3.2 Marking and identification .7
3.3 Materials .7
3.4 Test report.8
4 Test.8
4.1 General .8
4.2 Test sample preparation .8
4.3 Test and measurement methods .8
4.4 Pass/fail criteria.9
5 Performance requirements.9
5.1 Sample size, sequencing and grouping .9
5.2 Dimensions .9
5.3 Installation yield requirement .9
5.4 Test details and requirements.9
Annex A (informative) Fibre type .16
Annex B (normative) Sample size and product sourcing requirements.17
Bibliography .18
Table 1 – Test details and requirements .9
Table A.1 – Fibre type characteristics.16
Table B.1 – Sample size per test .17
61753-131-3 © IEC:2010 – 3 –
INTERNATIONAL ELECTROTECHNICAL COMMISSION
____________
FIBRE OPTIC INTERCONNECTING
DEVICES AND PASSIVE COMPONENTS –
PERFORMANCE STANDARD –
Part 131-3: Single-mode mechanical fibre splice for category U –
Uncontrolled environment
FOREWORD
1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of IEC is to promote
international co-operation on all questions concerning standardization in the electrical and electronic fields. To
this end and in addition to other activities, IEC publishes International Standards, Technical Specifications,
Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC
Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested
in the subject dealt with may participate in this preparatory work. International, governmental and non-
governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely
with the International Organization for Standardization (ISO) in accordance with conditions determined by
agreement between the two organizations.
2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international
consensus of opinion on the relevant subjects since each technical committee has representation from all
interested IEC National Committees.
3) IEC Publications have the form of recommendations for international use and are accepted by IEC National
Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC
Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any
misinterpretation by any end user.
4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications
transparently to the maximum extent possible in their national and regional publications. Any divergence
between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in
the latter.
5) IEC itself does not provide any attestation of conformity. Independent certification bodies provide conformity
assessment services and, in some areas, access to IEC marks of conformity. IEC is not responsible for any
services carried out by independent certification bodies.
6) All users should ensure that they have the latest edition of this publication.
7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and
members of its technical committees and IEC National Committees for any personal injury, property damage or
other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and
expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC
Publications.
8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is
indispensable for the correct application of this publication.
9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of
patent rights. IEC shall not be held responsible for identifying any or all such patent rights.
International Standard IEC 61753-131-3 had been prepared by subcommittee 86B: Fibre optic
interconnecting devices and passive components of IEC technical committee 86: Fibre optics.
This bilingual version (2010-07) replaces the English version.
The text of this standard is based on the following documents:
FDIS Report on voting
86B/2945/FDIS 86B/2983/RVD
Full information on the voting for the approval of this standard can be found in the report on
voting indicated in the above table.
– 4 – 61753-131-3 © IEC:2010
The French version of this standard has not been voted upon.
This publication has been drafted in accordance with the ISO/IEC Directives, Part 2.
A list of all parts of IEC 61753 series, published under the general title Fibre optic
interconnecting devices and passive components performance standard, can be found on the
IEC website.
Future standards in this series will carry the new general title as cited above. Titles of existing
standards in this series will be updated at the time of the next edition.
The committee has decided that the contents of this publication will remain unchanged until the
stability date indicated on the IEC web site under "http://webstore.iec.ch" in the data related to
the specific publication. At this date, the publication will be
• reconfirmed,
• withdrawn,
• replaced by a revised edition, or
• amended.
61753-131-3 © IEC:2010 – 5 –
INTRODUCTION
This part of IEC 61753 for mechanical splices defines the requirements for standard optical
performance under a set of specified conditions. The standard contains a series or a set of
tests and measurements with clearly stated conditions, severities and pass/fail criteria. The
series of tests, commonly referred to as an operating service environment or performance
category, is intended to be a basis to prove the product’s ability to satisfy the requirements of a
specific application, market sector or user group.
A product that has been shown to meet all the requirements of this performance standard may
be declared as complying with this performance standard. Products having the same
classification from one manufacturer that satisfy this performance standard, will operate within
the boundaries set by the performance standard. There is no guarantee that products from
different manufacturers, having the same classification and which conform to the same
performance standard, will provide an equivalent level of performance when they are used
together.
Conformance with IEC environmental policy according to IEC Guide 109 and concerning the need
to reduce the impact on the natural environment of fibre management system products during
all phases of their life – from acquiring materials to manufacturing, distribution, use, and end-
of-life treatment (i.e. re-use, recycling (recovery and disposal)) are not part of this standard,
but will be covered in the generic specification.
Conformance to a performance standard demonstrates that a product has passed a design
verification test. It is not a guarantee of lifetime assured performance or reliability. Reliability
testing are the subject of a separate test schedule, where the tests and severities selected are
such that they are truly representative of the requirements of this reliability test programme.
Consistency of manufacture should be maintained using a recognised Quality Assurance
programme whilst the reliability of product should be evaluated using the procedures
recommended in IEC 62005 series.
Tests and measurements are selected from the IEC 61300 series.
– 6 – 61753-131-3 © IEC:2010
FIBRE OPTIC INTERCONNECTING
DEVICES AND PASSIVE COMPONENTS –
PERFORMANCE STANDARD –
Part 131-3: Single-mode mechanical fibre splice for category U –
Uncontrolled environment
1 Scope
This part of IEC 61753 contains the minimum initial test and measurement requirements and
severities which a mechanical fibre splice will satisfy in order to be categorised as meeting the
requirements of single-mode fibre splice for use in uncontrolled environments.
2 Normative references
The following referenced documents are indispensable for the application of this document. For
dated references, only the edition cited applies. For undated references, the latest edition of
the referenced document (including any amendments) applies.
IEC 60721-3-2, Classification of environmental conditions – Part 3: Classification of groups of
environmental parameters and their severities – Section 2: Transportation
IEC 61073-1, Fibre optic interconnecting devices and passive components – Mechanical splices
and fusion splice protectors for optical fibres and cables – Part 1: Generic specification
IEC 61300-1, Fibre optic interconnecting devices and passive components – Basic test and
measurement procedures – Part 1: General and guidance
IEC 61300-2-1, Fibre optic interconnecting devices and passive components – Basic test and
measurement procedures – Part 2-1: Tests – Vibration (sinusoidal)
IEC 61300-2-4, Fibre optic interconnecting devices and passive components – Basic test and
measurement procedures – Part 2-4: Tests – Fibre/cable retention
IEC 61300-2-5, Fibre optic interconnecting devices and passive components – Basic test and
measurement procedures – Part 2-5: Tests – Torsion
IEC 61300-2-9, Fibre optic interconnecting devices and passive components – Basic test and
measurement procedures – Part 2-9:Tests – Shock
IEC 61300-2-17, Fibre optic interconnecting devices and passive components – Basic test and
measurement procedures – Part 2-17: Tests – Cold
IEC 61300-2-18, Fibre optic interconnecting devices and passive components – Basic test and
measurement procedures – Part 2-18: Tests – Dry heat – High temperature endurance
IEC 61300-2-22, Fibre optic interconnecting devices and passive components – Basic test and
measurement procedures – Part 2-22: Tests – Change of temperature
IEC 61300-2-26, Fibre optic interconnecting devices and passive components – Basic test and
measurement procedures – Part 2-26: Tests – Salt mist
61753-131-3 © IEC:2010 – 7 –
IEC 61300-2-27, Fibre optic interconnecting devices and passive components – Basic test and
measurement procedures – Part 2-27: Tests – Dust – Laminar flow
IEC 61300-2-33, Fibre optic interconnecting devices and passive components – Basic test and
measurement procedures – Part 2-33: Tests – Assembly and disassembly of fibre optic
closures
IEC 61300-3-3, Fibre optic interconnecting devices and passive components – Basic test and
measurement procedures – Part 3-3: Examinations and measurements – Active monitoring of
changes in attenuation and return loss
IEC 61300-3-4, Fibre optic interconnecting devices and passive components – Basic test and
measurement procedures – Part 2-26: Tests – Salt mist
IEC 61300-3-6, Fibre optic interconnecting devices and passive components – Basic test and
measurement procedures – Part 3-6: Examinations and measurements – Return Loss
IEC 61300-3-7, Fibre optic interconnecting devices and passive components – Basic test and
measurement procedures – Part 3-7: Examinations and measurements – Wavelength
dependence of attenuation and return loss of single mode components
IEC 61300-3-28, Fibre optic interconnecting devices and passive components – Basic test and
measurement procedures – Part 3-8: Examinations and measurements – Transient loss
3 General requirements
3.1 Storage, transportation and packaging
The classes of environmental conditions and their severities to which the mechanical splice
may be exposed during transportation are defined in IEC 60721-3-2. Normal transportation
time is considered to be 30 days or less.
The product, in its original packaging, shall be suitable for normal public or commercial
transportation and storage in weather protected non-temperature controlled storage
environments.
3.2 Marking and identification
Marking of the packaging of the mechanical splice shall be according to IEC 61073-1.
Product marking and identification shall survive the storage and transportation.
Each test sample should contain the following information at the minimum:
– manufacturer’s identification mark or logo;
– product designation, model or type;
– one of the following: lot number, batch number, date (at least month and year) of
production or serial number;
– expiry date (at least year) if the product contains components with a limited shelf life.
3.3 Materials
For all applicable materials, a Material Safety Data Sheet must be made available upon request.
– 8 – 61753-131-3 © IEC:2010
The materials of the mechanical splice shall be compatible with the other materials or solvents
that are likely to come into contact with them, for example cable filling compounds and
degreasing agents.
All materials that are likely to come in contact with personnel shall meet appropriate health and
safety regulations.
Polymeric materials shall not support mould growth.
Metallic elements shall be corrosion resistant. Dissimilar metals shall not be used in contact
with each other unless they are suitably finished to prevent electrolytic corrosion.
Materials which are not specified or which are not specifically described are left to the
discretion of the manufacturer.
3.4 Test report
Conformance to a performance standard shall be supported by a test report. The test report
shall clearly demonstrate that the tests were carried out in accordance with the requirements of
the performance standard and provide full details of the tests together with a pass/fail
declaration. An analysis of the cause of the failure shall be undertaken and any corrective
actions taken shall be described.
If design changes are made, an assessment should be carried out to determine whether full or
partial requalification should be done.
4 Test
4.1 General
The mechanical and environmental performance of a fibre splice is vital to the optical cabling
system. The purpose of testing is to demonstrate that the mechanical splice remains functional
under defined environmental conditions, without irreversible or reversible failures.
Optical performance testing is accomplished by subjecting the test specimen to a number of
mechanical and environmental conditions and measuring any optical performance deviations at
prescribed intervals during and after completion of each test.
4.2 Test sample preparation
The test samples are prepared by making a mechanical splice between identical fibres. Optical
test samples shall be installed according to the manufacturer’s installation instructions. The
fibres for the optical test samples are single-mode fibres as described in Annex A. The length
of the fibres shall be at least 2 m on both sides of the mechanical splice. For each fibre
construction (primary and secondary coated) a number of test samples will be prepared as
defined in Table B.1.
4.3 Test and measurement methods
All tests and measurements have been selected from the IEC 61300 series.
Unless otherwise stated in the individual test details, all attenuation measurements shall be
performed at 1 310 nm ± 25 nm, 1 550 nm ± 25 nm and 1 625 nm ± 25 nm for the
environmental optical tests, and at 1 550 nm ± 25 nm for the mechanical optical tests.
All optical losses indicated are referenced to the initial attenuation at the start of the test.
61753-131-3 © IEC:2010 – 9 –
No deviation from the specified test method is allowed.
Unless otherwise specified, tests should be carried out under standard atmospheric conditions
according to IEC 61300-1.
4.4 Pass/fail criteria
A product will have met the requirements of this standard provided no failures occur in any test.
5 Performance requirements
5.1 Sample size, sequencing and grouping
The sample size to be used for the tests shall be as defined in Table B.1. All samples shall be
subjected to Tests 1 to 2 at the start and at the end of the environmental or mechanical tests.
Samples for Tests 4 to 15 are randomly selected from the samples of Test 3. There is no
defined sequence in which Tests 4 to 15 are carried out.
5.2 Dimensions
No requirements on dimensions are available.
5.3 Installation yield requirement
The success rate or yield of installation of mechanical splices depends on many variables (e.g.
installer skills, ambient conditions, condition of tools). Typically no feedback is given on the
optical performance when a mechanical splice is made. Therefore, a small percentage of the
installed splices might not meet the expected performance level.
Ninety-seven per cent (97 %) of the splices shall meet the maximum attenuation and minimum
return loss requirements as specified by Tests 1 and 2 in Table 1 when 100 splices are made.
5.4 Test details and requirements
Table 1 – Test details and requirements
No. Test Requirement Details
1 Attenuation Attenuation per splice : Method: IEC 61300-3-4, insertion method.
≤ 0,25 dB max. Grade B Launch fibre
≥ 2 m. Only the fundamental
length: mode shall propagate at the
≤ 0,50 dB max. Grade C
mechanical splice and at the
detector.
Source type: LD
Launch conditions: The wavelength of the source
shall be longer than cut-off
wavelength of the fibre.
Source stability:
Better than ± 0,01 dB over the
measuring period or at least 1 h.
Detector linearity:
± 0,01 dB over the dynamic
range to be measured.
LD source central
1 310 nm ± 25 nm, 1 550 nm ±
wavelengths:
25 nm and 1 625 nm ± 25 nm
– 10 – 61753-131-3 © IEC:2010
Table 1 (Continued)
No. Test Requirement Details
2 Return loss Return loss per splice: Method: IEC 61300-3-6, method 1
≥ 60 dB Grade 1
Launch fibre ≥ 2 m. Only the fundamental
length: mode shall propagate at the
≥ 45 dB Grade 2
mechanical splice and at the
detector.
≥ 35 dB Grade 3
Source type: LD
Launch conditions: The wavelength of the source
shall be longer than cut-off
wavelength of the fibre.
Source stability: Better than ± 0,01 dB over the
measuring period or at least 1 h.
Detector linearity:
± 0,01 dB over the dynamic
range to be measured.
LD source central
1 310 nm ± 25 nm, 1 550 nm ±
wavelengths:
25 nm and 1 625 nm ± 25 nm
3 Installation yield 100 splices will be made. Method: IEC 61300-3-4, insertion method
A minimum of 97 % shall meet IEC 61300-3-6, method 1.
the maximum attenuation
Launch fibre
≥ 2 m. Only the fundamental
requirement of Test 1 and
length:
mode shall propagate at the
return loss requirement of Test
mechanical splice and at the
detector.
Source type: LD.
Launch conditions: The wavelength of the source
shall be longer than cut-off
wavelength of the fibre.
Source stability:
Better than ± 0,01 dB over the
measuring period or at least 1 h.
Detector linearity:
± 0,01 dB over the dynamic
range to be measured.
LD source central
1 310 nm ± 25 nm, 1 550 nm ±
wavelengths:
25 nm and 1 625 nm ± 25 nm
4 Wavelength Pass band: 1 260 nm-1 625 nm Method: IEC 61300-3-7, test sample
dependence of configuration according to
attenuation IEC 61300-3-4 cut-back method
or insertion method.
Attenuation per splice on
random selected fibres:
Launch fibre
≥ 2 m. Only the fundamental
length:
mode shall propagate at the
Grade B:
mechanical splice and at the
≤ 0,25 dB maximum
detector.
Source type: Unpolarized broadband light
source with spectral power >-
Grade C:
35 dBm/nm.
≤ 0,50 dB maximum
Launch conditions: The wavelength of the source
shall be longer than the cut-off
wavelength of the fibre.
Source stability:
Better than ± 0,05 dB over the
measuring period or at least 1 h.
Wavelength range 1 260 nm-1 625 nm
Detector linearity:
± 0,05 dB over the dynamic
range to be measured.
61753-131-3 © IEC:2010 – 11 –
Table 1 (Continued)
No. Test Requirement Details
5 Vibration Before and after the test, the Method: IEC 61300-2-1
(Sinusoidal) attenuation shall meet the
Frequency range: 10 Hz - 55 Hz
requirements of Test 1.
Constant vibration 0,75 mm
amplitude:
Before and after the test, the
Number of cycles 15
return loss shall meet the
requirements of Test 2.
(10-55-10 Hz):
Number of axis: The three main axes,
perpendicular one to each other.
During test, the change in
attenuation shall be ≤ ± 0,2 dB
Duration per axis: 0,5 h.
Specimen optically Yes
functioning :
Measurements Attenuation and return loss shall
required: be measured before, and after
the test.
During the test, the change in
attenuation shall be measured by
transient loss test method
IEC 61300-3-28 (Transient loss)
at 1 550 nm ± 25 nm
6 Shock Before and after the test, the Method: IEC 61300-2-9
attenuation shall meet
Acceleration force: Components: 500 g
the requirements of n
Test 1.
Duration shock: 1 ms half sine pulse.
Before and after the test, the
Number of axes: 3 main axes, perpendicular to
return loss shall meet the
each other.
requirements of Test 2
Number of shocks: 2 per axis (one in each
direction).
.
Specimen optically No
functioning:
Measurements Before and after each axis.
required:
7 Torsion Before and after the test, the Method: IEC 61300-2-5
attenuation shall meet the
Magnitude of the
2,0 N ± 0,5 N for primary and
requirements of Test 1.
load: secondary coated fibres.
Rate of load 0,1 N/s
Before and after the test, the
application:
return loss shall meet the
Load application 0,2 m from end of device.
requirements of Test 2
point:
Number of cycles: 10 cycles at +/- 180°
.
Specimen optically Yes
functioning :
Measurements Attenuation and return loss shall
required: be measured before and after the
test
– 12 – 61753-131-3 © IEC:2010
Table 1 (Continued)
No. Test Requirement Details
8 Fibre/cable Before and after the test, the Method: IEC 61300-2-4
retention attenuation shall meet the
Magnitude of the 5,0 N ± 0,5 N for secondary
requirements of Test 1.
load: coated fibres.
2,0 N ± 0,5 N for primary coated
Before and after the test, the
fibres.
return loss shall meet the
requirements of Test 2
Load application 0,3 m from the end of device.
point:
Load rate: 0,5 N/s for primary and
secondary coated fibre.
Duration of the 60 s
load:
Specimen optically Yes
functioning :
Measurements Attenuation and return loss shall
required: be measured before and after the
test
9 Assembly and Only for re-usable mechanical Method: IEC 61300-2-33 (test method
disassembly of splices. under consideration)
splices (only for
re-usable
Conditioning After each re-entry of the
mechanical
Before and after the test, the
between each mechanical splice, the splice
splices)
attenuation shall meet the
installation shall age by 1 temperature cycle
requirements of Test 1.
(–40 °C to +70 °C) as specified
in Test 13.
Before and after the test, the Number of re- 5
return loss shall meet the entries:
requirements of Test 2
Measurements Attenuation and return loss shall
required: be measured before and after
each ageing cycle.
10 Cold During the test, the maximum Method: IEC 61300-2-17
allowed change in attenuation
Pre-conditioning Standard atmospheric conditions
is ≤ ± 0,2 dB.
procedure: for 2 h.
Specimen optically Yes
Before and after the test, the
functioning:
spectral loss attenuation
Temperature:
–40 °C ± 2 °C
requirements of Test 1 shall be
met.
Duration of the 96 h
exposure:
Before, during and after the Operating 1 310 nm ± 25 nm, 1 550 nm ±
wavelength:
test, the return loss 25 nm and 1 625 nm ± 25 nm
requirement of Test 2 shall be
Measurements Attenuation and return loss shall
met
required: be measured before, and after
the test.
During the test, the change in
attenuation and return loss shall
be measured by test method
IEC 61300-3-3.
Maximum 1 h
sampling interval
during the test:
Recovery Allow specimen to recover at
procedure: room temperature during 2 h
61753-131-3 © IEC:2010 – 13 –
Table 1 (Continued)
No. Test Requirement Details
11 Dry heat During the test, the maximum Method: IEC 61300-2-18
allowed change in attenuation
Pre-conditioning Standard atmospheric conditions
is ≤ ± 0,2 dB.
procedure: for 2 h.
Specimen optically Yes
Before and after the test, the functioning:
spectral loss attenuation
Temperature:
+70 °C ± 2 °C
requirements of Test 1 shall be
met.
Duration of the 96 h
exposure:
Operating
Before, during and after the 1 310 nm ± 25 nm, 1 550 nm ±
test, the return loss wavelength:
25 nm and 1 625 nm ± 25 nm
requirement of Test 2 shall be
Measurements Attenuation and return loss shall
met.
required: be measured before and after the
test.
During the test, the change in
attenuation and return loss shall
be measured by test method
IEC 61300-3-3.
Maximum 1 h
sampling interval
during the test:
Recovery Allow specimen to recover at
procedure: room temperature during 2 h.
12 Damp heat, During the test, the maximum Method: IEC 61300-2-26
cyclic allowed change in attenuation
Pre-conditioning Standard atmospheric conditions
is ≤ ± 0,2 dB
procedure: for 2 h.
High temperature:
+55 °C ± 2 °C
Before and after the test, the
Low temperature:
spectral loss attenuation +25 °C ± 2 °C
requirements of Test 1 shall be
Humidity: 93 % RH ± 2 % RH
met.
Number of cycles: 4
Duration of each 24 h
Before, during and after the
test, the return loss cycle:
requirement of Test 2 shall be
Specimen optically Yes
met.
functioning:
Wavelength:
1 310 nm ± 25 nm, 1 550 nm ±
25 nm and 1 625 nm ± 25 nm
Measurements Attenuation and return loss shall
required: be measured before and after the
test.
During the test, the change in
attenuation and return loss shall
be measured by test method
IEC 61300-3-3.
Maximum 15 min
sampling interval
during the test:
Recovery Allow specimen to recover at
procedure: room temperature during 2 h.
– 14 – 61753-131-3 © IEC:2010
Table 1 (Continued)
No. Test Requirement Details
13 Change of During the test, the maximum Method: IEC 61300-2-22 (Test Nb)
temperature allowed change in attenuation
Pre-conditioning Standard atmospheric conditions
is ≤ ± 0,2 dB
procedure: for 2 h.
High temperature: +70 °C ± 2 °C
Before and after the test, the
spectral loss attenuation Low temperature:
–40 °C ± 2 °C
requirements of Test 1 shall be
Number of cycles: 12
met.
Rate of 1 °C/min
temperature
Before, during and after the
change:
test, the return loss
requirement of Test 2 shall be Duration at 1 h
met. extreme
temperatures:
Specimen optically Yes
functioning:
Wavelength: 1 310 nm ± 25 nm, 1 550 nm ±
25 nm and 1 625 nm ± 25 nm
Measurements Attenuation and return loss shall
required: be measured before and after the
test.
During the test, the change in
attenuation and return loss shall
be measured by test method
IEC 61300-3-3.
Maximum 15 min
sampling interval
during the test:
Recovery Allow specimen to recover at
procedure: room temperature during 2 h
14 Dust - Laminar Before and after the test, the Method: IEC 61300-2-27
flow attenuation shall meet the
Preconditioning 2 h at normal ambient conditions.
requirements of Test 1.
procedure:
Temperature: +35 °C ± 2 °C
Before and after the test, the
return loss shall meet the Relative humidity:
+60 % ± 2 %
requirements of test 2.
Dust type: Talc
Dust particle
< 150 μm
diameter:
3 3
Dust
25 g/m ± 5 g/m
concentration:
Test duration: 10 min
Specimen optically No
functioning or not:
Measurements Before and after the test, at
required: standard atmospheric conditions.
Recovery Allow specimen to recover at
procedure: room temperature during 2 h
61753-131-3 © IEC:2010 – 15 –
Table 1 (Continued)
No. Test Requirement Details
15 Salt mist Before and after the test, the Method: IEC 61300-2-26
attenuation shall meet the
Preconditioning 2 h at normal ambient conditions.
requirements of Test 1.
procedure:
Temperature: +35 °C ± 2 °C
Before and after the test, the
return loss shall meet the Salt solution 5 % ± 1 %
requirements of Test 2 (NaCl)
concentration:
PH: Between 6,5 and 7,2
No significant difference in
visual aspect shall be noticed
Test duration: 96 h
Specimen optically No
functioning:
Measurements Before and after the test, at
required: standard atmospheric conditions.
Recovery Allow specimen to recover at
procedure: room temperature during 2 h.
– 16 – 61753-131-3 © IEC:2010
Annex A
(informative)
Fibre type
Table A.1 – Fibre type characteristics
Fibre type: Dispersion unshifted - IEC 60793-2-50 Type B1.1
Proof stress strain:
≥ 1%
Nominal MFD at 1 310 nm: 8,6 μm – 9,5 μm
MFD tolerance:
± 0,6 μm
Core concentricity error
≤ 0,6 μm
Cabled fibre cut off wavelength: ≤ 1 260 nm
1 310 nm loss performance:
≤ 0,40 dB/km
1 550 nm loss performance:
≤ 0,30 dB/km
Cladding diameter: 125 μm ± 1 μm
Primary coating diameter - uncoloured:
245 μm ± 10 μm
Primary coating diameter - coloured:
250 μm ± 15 μm
Secondary coating diameter: 900 μm ± 100 μm
61753-131-3 © IEC:2010 – 17 –
Annex B
(normative)
Sample size and product sourcing requirements
Table B.1 – Sample size per test
No. Test Sample size Sourcing
1 Attenuation (criterion test) - -
2 Return loss (criterion test) - -
3 Installation yield 100 New
4 Wavelength dependence of attenuation 10 3
5 Vibration (sinusoidal) 4 3
6 Shock 4 3
7 Torsion 4 3
8 Fibre retention 4 3
9 Assembly and disassembly 4 3
10 Cold 4 3
11 Dry heat 4 3
12 Damp heat, cyclic 4 3
13 Change of temperature 4 3
14 Dust - Laminar flow 4 3
15 Salt mist 4 3
NOTE Tests 4 to 15 may be performed in any order. Samples for Tests 4 to 15 should be randomly selected
from the samples of Test 3 (that meet the optical performance criteria of Tests 1 and 2).
– 18 – 61753-131-3 © IEC:2010
Bibliography
IEC 60793-2-50:2008, Optical fibres – Part 2-50: Product specifications – Sectional
specification for class B single-mode fibres
IEC 61753-1, Fibre optic interconnecting devices and passive components performance
standard – Part 1: General and guidance for performance standards
IEC 61300-2-46, Fibre optic interconnecting devices and passive components – Basic test and
measurement procedures – Part 2-46: Tests – Damp heat, cyclic
IEC 62005 (all parts), Reliability of fibre optic interconnecting devices and passive components
IEC Guide 109, Environmental aspects – Inclusion in electrotechnical product standards
___________
– 20 – 61753-131-3 © CEI:2010
SOMMAIRE
AVANT-PROPOS.21
INTRODUCTION.23
1 Domaine d’application.24
2 Références normatives.24
3 Exigences générales .25
3.1 Stockage, transport et emballage .25
3.2 Identification et marquage .25
3.3 Matériaux .26
3.4 Rapport d’essai .26
4 Essai .26
4.1 Généralités.26
4.2 Préparation d’un échantillon d’essai .26
4.3 Méthodes d’essai et de mesure .27
4.4 Critères d’acceptation/rejet.27
5 Exigences de performances .27
5.1 Nombre d'échantillons, groupage et séquençage.27
5.2 Dimensions .27
5.3 Exigences sur le rendement de l'installation .27
5.4 Exigences et détails des essais.28
Annexe A (informative) Type de fibre .37
Annexe B (normative) Nombre d’échantillons et exigences d’approvisionnement des
produits .38
Bibliographie.39
Tableau 1 – Exigences et détails des essais .28
Tableau A.1 – Caractéristiques des types de fibre .37
Tableau B.1 – Nombre d’échantillons par essai.38
61753-131-3 © CEI:2010 – 21 –
COMMISSION ÉLECTROTECHNIQUE INTERNATIONALE
____________
DISPOSITIFS D'INTERCONNEXION ET
COMPOSANTS PASSIFS À FIBRES OPTIQUES –
NORME DE PERFORMANCE –
Partie 131-3: Epissure mécanique de fibres
unimodales pour catégorie U –
Environnement non contrôlé
AVANT-PROPOS
1) La Commission Electrotechnique Internationale (CEI) est une organisation mondiale de normalisation
composée de l'ensemble des comités électrotechniques nationaux (Comités nationaux de la CEI). La CEI a
pour objet de favoriser la coopération internationale pour toutes les questions de normalisation dans les
domaines de l'électricité et de l'électronique. A cet effet, la CEI – entre autres activités – publie des Normes
internationales, des Spécifications techniques, des Rapports techniques, des Spécifications accessibles au
public (PAS) et des Guides (ci-après dénommés "Publication(s) de la CEI"). Leur élaboration est confiée à des
comités d'études, aux travaux desquels tout Comité national intéressé par le sujet traité peut participer. Les
organisations internationales, gouvernementales et non gouvernementales, en liaison avec la CEI, participent
également aux travaux. La CEI collabore étroitement avec l'Organisation Internationale de Normalisation (ISO),
selon des conditions fixées par accord entre les deux organisations.
2) Les décisions ou accords officiels de la CEI concernant les questions techniques représentent, dans la mesure
du possible, un accord international sur les sujets étudiés, étant donné que les Comités nationaux de la CEI
intéressés sont représentés dans chaque comité d’études
...