IEC 61169-1:2013, which is a generic specification, relates to radio frequency connectors for r.f. transmission lines for use in telecommunications, electronics and similar equipment. It provides the basis for the sectional standards, which apply to individual connector types. It is intended to establish uniform concepts and procedures concerning:
- terminology;
- standard ratings and characteristics;
- testing and measuring procedures concerning electrical, mechanical and climatic properties;
- classification of connectors with regard to climatic testing procedures involving temperature and humidity.
The test methods and procedures of this standard are intended for acceptance and type approval testing. This second edition cancels and replaces the first edition, published in 1992, its Amendments 1 (1996) and 2 (1997). This edition constitutes a technical revision. With respect to the previous edition, tests methods have been updated as well as terminology. The contents of the corrigendum of February 2016 have been included in this copy.

Status
Published
Publication Date
09-Jul-2013
Current Stage
PPUB - Publication issued
Start Date
10-Jul-2013
Completion Date
15-Jun-2013

Buy Documents

Standard

IEC 61169-1:2013 - Radio frequency connectors - Part 1: Generic specification - General requirements and measuring methods Released:7/10/2013

ISBN:978-2-8322-0925-7
English language (59 pages)
sale 15% off
Preview
sale 15% off
Preview
Standard

IEC 61169-1:2013 - Radio frequency connectors - Part 1: Generic specification - General requirements and measuring methods Released:7/10/2013

ISBN:978-2-8322-3230-9
English and French language (125 pages)
sale 15% off
Preview
sale 15% off
Preview

Overview - IEC 61169-1:2013 (Radio frequency connectors, Part 1)

IEC 61169-1:2013 is the generic specification for radio frequency (RF) connectors used with RF transmission lines in telecommunications, electronics and similar equipment. Edition 2.0 (2013) is a technical revision that replaces the 1992 edition and its amendments, updates test methods and terminology, and includes the February 2016 corrigendum. The standard defines uniform concepts, terminology, ratings and measuring procedures that form the basis for sectional standards covering individual connector types.

Key technical topics and requirements

The standard sets out general requirements and measuring methods across three main test domains:

  • Electrical tests and measurements

    • Return loss / reflection (time- and frequency-domain measurement techniques)
    • Power rating and dielectric material considerations
    • Insulation resistance and voltage proof
    • Screening effectiveness and surge/corona (discharge) tests
    • Intermodulation level (PIM) testing for non-linear behavior
  • Mechanical tests and procedures

    • Visual and dimensional inspection
    • Engagement/separation forces, insertion force, torque and coupling strength
    • Vibration, bump and shock endurance
    • Mechanical endurance (mating cycles), cable clamp effectiveness (pull, bend, torsion)
  • Climatic conditioning and environmental testing

    • Classification into climatic categories (references IEC 60068-1)
    • Damp heat, temperature cycling, high/low temperature endurance
    • Salt mist, water immersion, resistance to solvents and contaminating fluids
    • Sealing tests for non-hermetic and hermetic connectors

Other important elements include terms/definitions, units and symbols, quality assessment (acceptance and periodic tests), test schedules, marking and specification structure (sectional and detail specifications).

Practical applications and users

IEC 61169-1 is primarily used for:

  • Component and RF connector manufacturers for design verification and type approval
  • Test laboratories performing acceptance, periodic and qualification testing
  • Systems integrators and procurement teams requiring compliant connector specifications
  • Certification bodies and conformity assessment organizations assessing product compliance

It ensures consistent RF connector performance, reliability and interoperability across telecom networks, broadcast, aerospace, test equipment and commercial RF systems.

Related standards and notes

  • Sectional standards (other parts of IEC 61169) define requirements for specific connector types.
  • Climatic categories referenced from IEC 60068-1.
  • Users should obtain the latest editions, corrigenda and any applicable sectional parts when specifying or testing RF connectors.

Keywords: IEC 61169-1, RF connectors, radio frequency connectors, measuring methods, return loss, PIM, power rating, climatic testing, connector testing.

Relations

Effective Date
05-Sep-2023
Effective Date
05-Sep-2023
Effective Date
05-Sep-2023

Buy Documents

Standard

IEC 61169-1:2013 - Radio frequency connectors - Part 1: Generic specification - General requirements and measuring methods Released:7/10/2013

ISBN:978-2-8322-0925-7
English language (59 pages)
sale 15% off
Preview
sale 15% off
Preview
Standard

IEC 61169-1:2013 - Radio frequency connectors - Part 1: Generic specification - General requirements and measuring methods Released:7/10/2013

ISBN:978-2-8322-3230-9
English and French language (125 pages)
sale 15% off
Preview
sale 15% off
Preview

Get Certified

Connect with accredited certification bodies for this standard

ANCE

Mexican certification and testing association.

EMA Mexico Verified

Intertek Slovenia

Intertek testing, inspection, and certification services in Slovenia.

UKAS Slovenia Verified

LNE (Laboratoire National de Métrologie et d'Essais)

French national laboratory for metrology and testing.

COFRAC France Verified

Sponsored listings

Frequently Asked Questions

IEC 61169-1:2013 is a standard published by the International Electrotechnical Commission (IEC). Its full title is "Radio frequency connectors - Part 1: Generic specification - General requirements and measuring methods". This standard covers: IEC 61169-1:2013, which is a generic specification, relates to radio frequency connectors for r.f. transmission lines for use in telecommunications, electronics and similar equipment. It provides the basis for the sectional standards, which apply to individual connector types. It is intended to establish uniform concepts and procedures concerning: - terminology; - standard ratings and characteristics; - testing and measuring procedures concerning electrical, mechanical and climatic properties; - classification of connectors with regard to climatic testing procedures involving temperature and humidity. The test methods and procedures of this standard are intended for acceptance and type approval testing. This second edition cancels and replaces the first edition, published in 1992, its Amendments 1 (1996) and 2 (1997). This edition constitutes a technical revision. With respect to the previous edition, tests methods have been updated as well as terminology. The contents of the corrigendum of February 2016 have been included in this copy.

IEC 61169-1:2013, which is a generic specification, relates to radio frequency connectors for r.f. transmission lines for use in telecommunications, electronics and similar equipment. It provides the basis for the sectional standards, which apply to individual connector types. It is intended to establish uniform concepts and procedures concerning: - terminology; - standard ratings and characteristics; - testing and measuring procedures concerning electrical, mechanical and climatic properties; - classification of connectors with regard to climatic testing procedures involving temperature and humidity. The test methods and procedures of this standard are intended for acceptance and type approval testing. This second edition cancels and replaces the first edition, published in 1992, its Amendments 1 (1996) and 2 (1997). This edition constitutes a technical revision. With respect to the previous edition, tests methods have been updated as well as terminology. The contents of the corrigendum of February 2016 have been included in this copy.

IEC 61169-1:2013 is classified under the following ICS (International Classification for Standards) categories: 33.120.30 - RF connectors. The ICS classification helps identify the subject area and facilitates finding related standards.

IEC 61169-1:2013 has the following relationships with other standards: It is inter standard links to IEC 61169-1:2013/COR1:2016, IEC 61169-1:1992, IEC 61169-1:1992/AMD2:1997. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.

IEC 61169-1:2013 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.

Standards Content (Sample)


IEC 61169-1 ®
Edition 2.0 2013-07
INTERNATIONAL
STANDARD
colour
inside
Radio frequency connectors –
Part 1: Generic specification – General requirements and measuring methods

All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form
or by any means, electronic or mechanical, including photocopying and microfilm, without permission in writing from
either IEC or IEC's member National Committee in the country of the requester.
If you have any questions about IEC copyright or have an enquiry about obtaining additional rights to this publication,
please contact the address below or your local IEC member National Committee for further information.

IEC Central Office Tel.: +41 22 919 02 11
3, rue de Varembé Fax: +41 22 919 03 00
CH-1211 Geneva 20 info@iec.ch
Switzerland www.iec.ch
About the IEC
The International Electrotechnical Commission (IEC) is the leading global organization that prepares and publishes
International Standards for all electrical, electronic and related technologies.

About IEC publications
The technical content of IEC publications is kept under constant review by the IEC. Please make sure that you have the
latest edition, a corrigenda or an amendment might have been published.

Useful links:
IEC publications search - www.iec.ch/searchpub Electropedia - www.electropedia.org
The advanced search enables you to find IEC publications The world's leading online dictionary of electronic and
by a variety of criteria (reference number, text, technical electrical terms containing more than 30 000 terms and
committee,…). definitions in English and French, with equivalent terms in
It also gives information on projects, replaced and additional languages. Also known as the International
withdrawn publications. Electrotechnical Vocabulary (IEV) on-line.

IEC Just Published - webstore.iec.ch/justpublished Customer Service Centre - webstore.iec.ch/csc
Stay up to date on all new IEC publications. Just Published If you wish to give us your feedback on this publication
details all new publications released. Available on-line and or need further assistance, please contact the
also once a month by email. Customer Service Centre: csc@iec.ch.

IEC 61169-1 ®
Edition 2.0 2013-07
INTERNATIONAL
STANDARD
colour
inside
Radio frequency connectors –
Part 1: Generic specification – General requirements and measuring methods

INTERNATIONAL
ELECTROTECHNICAL
COMMISSION
PRICE CODE
XA
ICS 33.120.30 ISBN 978-2-8322-0925-7

– 2 – 61169-1 © IEC:2013(E)
CONTENTS
FOREWORD . 5
1 Scope . 7
2 Normative references . 7
3 Terms and definitions . 8
3.1 General, parts of connectors . 8
3.2 Basic connector terms . 9
3.3 Constructional terms . 10
3.4 Sealing . 11
3.5 Miscellaneous terms . 11
3.6 General electrotechnical terms . 12
4 Units, symbols and dimensions . 12
4.1 Units and symbols . 12
4.2 Dimensions . 13
4.2.1 Details to be provided in relevant specifications . 13
4.2.2 Dimensional units to be used in specifications . 13
5 Standards ratings and characteristics . 13
6 Classifications into climatic categories . 13
7 IEC type designation . 14
8 Testing . 14
9 Test methods. 14
9.1 Mechanical inspection . 14
9.1.1 Visual inspection . 14
9.1.2 Dimensions. 15
9.2 Electrical tests and measuring procedures . 15
9.2.1 Return loss . 15
9.2.2 Power rating . 19
9.2.3 Contact resistance, outer conductor and centre conductor continuity
(mated cabled connectors) . 20
9.2.4 Centre and outer conductor contact continuity under severe
mechanical conditioning . 22
9.2.5 Insulation resistance . 22
9.2.6 Voltage proof . 23
9.2.7 Screening effectiveness . 24
9.2.8 Discharge test (corona test) . 24
9.2.9 Intermodulation level (PIM) . 25
9.2.10 Surge withstand . 26
9.3 Mechanical tests and measuring procedures . 26
9.3.1 General . 26
9.3.2 Soldering . 26
9.3.3 Vibration . 26
9.3.4 Insertion force (resilient contacts) . 27
9.3.5 Centre contact captivation . 28
9.3.6 Engagement and separation forces and torques . 28
9.3.7 Effectiveness of clamping device against cable rotation (nutation of
cable end) . 29
9.3.8 Effectiveness of clamping device against cable pulling . 29

61169-1 © IEC:2013(E) – 3 –
9.3.9 Effectiveness of clamping device against cable bending . 30
9.3.10 Effectiveness of clamping device against cable torsion . 31
9.3.11 Strength of coupling mechanism . 32
9.3.12 Safety wire hole pull-out bending moment (and shearing force) . 32
9.3.13 Bump . 33
9.3.14 Shock . 34
9.3.15 Mechanical endurance . 35
9.4 Climatic conditionings and tests . 35
9.4.1 Conditionings . 35
9.4.2 Climatic sequence . 36
9.4.3 Damp heat, steady state . 37
9.4.4 Change of temperature . 37
9.4.5 High temperature endurance . 38
9.4.6 Low temperature endurance . 39
9.4.7 Sealing non-hermetic sealed connectors. 40
9.4.8 Hermetically sealed connectors . 40
9.4.9 Water immersion test . 41
9.4.10 Salt mist . 43
9.4.11 Resistance to solvents and contaminating fluids . 43
9.4.12 Sulphur dioxide test . 45
10 Quality assessment . 46
10.1 General . 46
10.2 Quality assessment steps . 46
10.2.1 Primary stage of manufacture . 46
10.2.2 Structurally similar components . 46
10.2.3 General principle for obtaining quality conformance . 46
10.3 Test schedule and inspection requirements . 46
10.3.1 Acceptance tests . 46
10.3.2 Periodic tests. 48
10.4 Procedures for quality conformance . 49
10.4.1 Quality conformance inspection . 49
10.4.2 Quality conformance and its maintenance . 49
10.5 Test and measurement procedures . 49
10.5.1 General . 49
10.5.2 Schedule of basic test groupings for acceptance and periodic tests . 50
10.6 Specifications . 50
10.6.1 Specification structures . 50
10.6.2 Sectional specification (SS) . 50
10.6.3 Detail specification (DS) . 50
10.6.4 Blank detail specification . 51
10.6.5 Blank detail specification pro-forma for XXXX connectors . 52
11 Marking . 57
11.1 Marking of component . 57
11.2 Marking and contents of package . 57
Annex A (informative) Simulated sea-water solution for use with salt mist test (marine
environment, see 9.4.10.3) . 58
Bibliography . 59

– 4 – 61169-1 © IEC:2013(E)
Figure 1 – graphical symbols . 16
Figure 2 – General principle . 16
Figure 3 – Measuring set-up for two-connector procedure . 17
Figure 4 – Example of a time domain reflectometer measurement recording . 18
Figure 5 – Equipment set-up for the measurement of reflection in time domain . 19
Figure 6 – Possible test arrangements . 23
Figure 7 – Measuring circuit for the discharge test . 25
Figure 8 – Test arrangement for nutation . 29
Figure 9 – Test arrangement for pulling . 30
Figure 10 – Bending. 31
Figure 11 – Cable torsion . 31
Figure 12 – Temperature curve profile . 41
Figure 13 – Container/jumper arrangement . 42

Table 1 – Preferred climatic categories (see IEC 60068-1) . 13
Table 2 – Dielectric materials ratings . 20
Table 3 – Severities for vibration. 27
Table 4 – Recommended severities for bump . 33
Table 5 – Recommended severities for shocks . 34
Table 6 – Recommended severities for low temperature tests . 39
Table 7 – Fuels, lubricants, hydraulic fluids and anti-freeze agents . 44
Table 8 – Cleaning agents and moisture repellents . 44
Table 9 – Acceptance tests . 47
Table 10 – Periodic tests . 48

61169-1 © IEC:2013(E) – 5 –
INTERNATIONAL ELECTROTECHNICAL COMMISSION
____________
RADIO FREQUENCY CONNECTORS –
Part 1: Generic specification –
General requirements and measuring methods

FOREWORD
1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of IEC is to promote
international co-operation on all questions concerning standardization in the electrical and electronic fields. To
this end and in addition to other activities, IEC publishes International Standards, Technical Specifications,
Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC
Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested
in the subject dealt with may participate in this preparatory work. International, governmental and non-
governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely
with the International Organization for Standardization (ISO) in accordance with conditions determined by
agreement between the two organizations.
2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international
consensus of opinion on the relevant subjects since each technical committee has representation from all
interested IEC National Committees.
3) IEC Publications have the form of recommendations for international use and are accepted by IEC National
Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC
Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any
misinterpretation by any end user.
4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications
transparently to the maximum extent possible in their national and regional publications. Any divergence
between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in
the latter.
5) IEC itself does not provide any attestation of conformity. Independent certification bodies provide conformity
assessment services and, in some areas, access to IEC marks of conformity. IEC is not responsible for any
services carried out by independent certification bodies.
6) All users should ensure that they have the latest edition of this publication.
7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and
members of its technical committees and IEC National Committees for any personal injury, property damage or
other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and
expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC
Publications.
8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is
indispensable for the correct application of this publication.
9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of
patent rights. IEC shall not be held responsible for identifying any or all such patent rights.
International Standard IEC 61169-1 has been prepared by subcommittee 46F: R.F. and
microwave passive components, of IEC technical committee 46: Cables, wires, waveguides,
R.F. connectors, R.F. and microwave passive components and accessories.
This second edition cancels and replaces the first edition, published in 1992, its Amendments
1 (1996) and 2 (1997). This edition constitutes a technical revision.
With respect to the previous edition, tests methods have been updated as well as terminology.
The text of this standard is based on the following documents:
CDV Report on voting
46F/216/CDV 46F/226/RVC
Full information on the voting for the approval of this standard can be found in the report on
voting indicated in the above table.

– 6 – 61169-1 © IEC:2013(E)
This publication has been drafted in accordance with the ISO/IEC Directives, Part 2.
A list of all the parts in the IEC 61169 series, published under the general title Radio
frequency connectors, can be found on the IEC website.
The committee has decided that the contents of this publication will remain unchanged until
the stability date indicated on the IEC web site under "http://webstore.iec.ch" in the data
related to the specific publication. At this date, the publication will be
• reconfirmed,
• withdrawn,
• replaced by a revised edition, or
• amended.
A bilingual version of this publication may be issued at a later date.
The contents of the corrigendum of February 2016 have been included in this copy.

IMPORTANT – The 'colour inside' logo on the cover page of this publication indicates
that it contains colours which are considered to be useful for the correct
understanding of its contents. Users should therefore print this document using a
colour printer.
61169-1 © IEC:2013(E) – 7 –
RADIO FREQUENCY CONNECTORS –
Part 1: Generic specification –
General requirements and measuring methods

1 Scope
This part of IEC 61169, which is a generic specification, relates to radio frequency connectors
for r.f. transmission lines for use in telecommunications, electronics and similar equipment.
It
It provides the basis for the sectional standards, which apply to individual connector types.
is intended to establish uniform concepts and procedures concerning:
– terminology;
– standard ratings and characteristics;
– testing and measuring procedures concerning electrical, mechanical and climatic
properties;
– classification of connectors with regard to climatic testing procedures involving
temperature and humidity.
The test methods and procedures of this standard are intended for acceptance and type
approval testing.
2 Normative references
The following documents, in whole or in part, are normatively referenced in this document and
are indispensable for its application. For dated references, only the edition cited applies. For
undated references, the latest edition of the referenced document (including any
amendments) applies.
IEC 60027 (all parts), Letter symbols to be used in electrical technology
IEC 60050 (all parts), International Electrotechnical Vocabulary (available from:
http://www.electropedia.org)
IEC 60068-1, Environmental testing – Part 1: General and guidance
IEC 60068-2-1:1990, Environmental testing – Part 2-1: Tests – Test A: Cold
IEC 60068-2-2:1974, Environmental testing – Part 2-2: Tests – Test B: Dry heat
IEC 60068-2-6, Environmental testing – Part 2-6: Tests – Test Fc: Vibration (sinusoidal)
IEC 60068-2-11, Environmental testing – Part 2-11: Tests – Test Ka: Salt mist
IEC 60068-2-13, Environmental testing – Part 2-13: Tests – Test M: Low air pressure
IEC 60068-2-14:2009, Environmental testing – Part 2-14: Tests – Test N: Change of
temperature
IEC 60068-2-17, Environmental testing – Part 2-17: Tests – Test Q: Sealing
_____________
This publication has been withdrawn.
This publication has been withdrawn.

– 8 – 61169-1 © IEC:2013(E)
IEC 60068-2-20, Environmental testing – Part 2-20: Tests – Test T: Test methods for
solderability and resistance to soldering heat of devices with leads
IEC 60068-2-27, Environmental testing – Part 2-27: Tests – Test Ea and guidance: Shock
IEC 60068-2-29, Environmental testing – Part 2: Tests – Test Eb and guidance: Bump
IEC 60068-2-30, Environmental testing – Part 2-30: Tests – Test Db: Damp heat, cyclic (12 h
+ 12 h cycle)
IEC 60068-2-42, Environmental testing – Part 2-42: Tests – Test Kc: Sulphur dioxide test for
contacts and connections
IEC 60068-2-52:1996, Environmental testing – Test Kb: Salt mist, cyclic (sodium, chloride
solution)
IEC 60068-2-54, Environmental testing – Part 2-54: Tests – Test Ta: Solderability testing of
electronic components by the wetting balance method
IEC 60068-2-61:1991, Environmental testing – Part 2-61: Test methods – Test Z/ABDM:
Climatic sequence
IEC 60068-2-78, Environmental testing – Part 2-78: Tests – Test Cab: Damp heat, steady
state
IEC 60457-1, Rigid precision coaxial lines and their associated precision connectors – Part 1:
General requirements and measuring methods
IEC 60617, Graphical symbols for diagrams (available from: http://std.iec.ch/iec60617)
IEC 62153 (all parts), Metallic communication cables test methods
IEC 61726, Cable assemblies, cables, connectors and passive microwave components –
Screening attenuation measurement by the reverberation chamber method
IEC 62037 (all parts), Passive RF and microwave devices, intermodulation level measurement
ISO 1000, SI units and recommendations for the use of their multiples and of certain other
units
3 Terms and definitions
For the purposes of this document, the following terms and definitions apply.
NOTE Some of the terms defined are not used in the present document, but may be used in the different sectional
specifications.
3.1 General, parts of connectors
3.1.1
contact (electrical)
state in which individual electrically conductive parts are in such close mechanical touch as to
provide a low resistance path to electrical current in either direction
3.1.2
contact
a component which mates with a corresponding element to provide an
conductive element in
electrical path (to provide electrical contact)
_____________
This publication has been withdrawn.

61169-1 © IEC:2013(E) – 9 –
3.1.3
male (pin) contact
contact intended to make electrical engagement on its outer surface and which will enter a
female (socket) contact
3.1.4
female (socket) contact
contact intended to make electrical engagement on its inner surface and which will accept
entry of a male (pin) contact
3.1.5
hermaphroditic contact
contact which is intended to mate with an identical contact
3.1.6
resilient contact
contact having elastic properties to provide a force to its mating part
3.2 Basic connector terms
3.2.1
connector
component normally attached to a cable or mounted on a piece of apparatus (excluding an
adaptor) for electrically joining separable parts of a transmission line system
3.2.2
connector pair
two connectors having complementary mating faces and locking means, so as to be mateable
and interlockable
3.2.3
series type
terms characterizing the particular mating faces and locking means of a connector pair with
regard to construction and dimension
Note 1 to entry: The term "series" is sometimes used as an approximate synonym of 'type' for designating the
entirety of connector styles with identical mating face and locking means.
3.2.4
style
particular form or shape of connector, as well as a combination of connectors of the same
type
Note 1 to entry: For "adaptor", see 3.5.1 to 3.5.5: a 'within-type adaptor" may also be considered as a particular
style of a given type.
Note 2 to entry: Examples are: free and fixed connectors, both straight and right angle, within-type adaptors
straight and right angle.
3.2.5
variant
variation of a style, in particular details, such as cable-entry dimensions
3.2.6
grade
qualification of a connector with regard to mechanical and electrical precision in particular
with respect to a defined return loss
3.2.7
general purpose connector: Grade 2
connector making use of the widest permitted dimensional deviations (tolerances) so as still
to guarantee minimum stated performance and intermateability
Note 1 to entry: A requirement for the return loss may or may not be specified.

– 10 – 61169-1 © IEC:2013(E)
3.2.8
high performance connector: Grade 1
connector for which limits of return loss are specified as a function of frequency.
Note 1 to entry: No tighter dimensional tolerances than those applicable to Grade 2 are normally specified. The
manufacturer is responsible, however, for choosing tighter tolerances where necessary to ensure that the return
loss requirements are met.
3.2.9
standard test connector: Grade 0
precisely made connector of a particular type used to carry out return loss measurements on
Grade 1 and Grade 2 connectors, contributing only negligible errors to the measuring result
Note 1 to entry: The standard test connector is often part of an inner-type adaptor which allows connection with a
precision connector forming part of the measuring equipment.
3.2.10
precision connector
connector that has coincident mechanical and electrical reference planes, air dielectric, and
has the property of making connections with a high degree of repeatability without introducing
significant reflections, loss or leakage
Note 1 to entry: It is intended for mounting on air-lines and instruments. Precision connectors can be of the
hermaphroditic type, flange type or of the pin and socket type as stated in IEC 60457-1.
3.2.11
laboratory precision connector
LPC
precision connector without dielectric support for the centre conductor
3.2.12
general precision connector
GPC
precision connector with self-contained dielectric support capable of supporting the un-
supported centre conductor of an LPC and standard air-line which it is mated
3.3 Constructional terms
3.3.1
male connector/pin connector
connector containing a male (pin) centre contact
3.3.2
female connector/socket connector
connector containing a female (socket) centre contact
3.3.3
plug connector
connector featuring the active part of the coupling mechanism, i.e. the nut or bayonet ring,
and which normally is a free contact
Note 1 to entry: Depending on the particular type, a plug may be a male or female connector.
3.3.4
socket
connector complimentary to the plug
3.3.5
hermaphroditic connector
connector which mates with an identical connector
3.3.6
free connector
connector for attachment to a free end of a cable
Note 1 to entry: If not specified as fixed, a connector is assumed to be free.

61169-1 © IEC:2013(E) – 11 –
3.3.7
fixed connector
connector with provision for attachment to a mounting surface
3.3.8
triaxial
transmission line comprising three concentric conductors having a common axis and with
each conductor insulated from the other two
3.4 Sealing
3.4.1
sealed connector
connector employing a seal capable of fulfilling specified gas-, moisture- or liquid tightness
requirements
3.4.2
barrier seal
seal preventing the passage of gases, moisture or liquids in an axial direction within the body
shell of a connector
3.4.3
panel seal
seal preventing the passage of gases, moisture or liquids between the fixed connector or
adaptor body shell and the panel via the mounting hole(s)
Note 1 to entry: The sealing member is often provided as a discrete item.
3.4.4
mating face seal
seal preventing the passage of gases, moisture or liquids into the interface space of a pair of
mated connectors
3.4.5
hermetic seal
seal meeting the requirements specified on application of Test Qk of IEC 60068-2-17
3.5 Miscellaneous terms
3.5.1
adaptor
two-port device for joining two transmission lines having non-mating connectors
3.5.2
fixed adaptor
adaptor with provision for attachment to a mounting surface
Note 1 to entry: If not specified as fixed, an adaptor is assumed to be free.
3.5.3
within-type adaptor
adaptor for use between two or more connectors all of the same type
3.5.4
inter-type adaptor
adaptor for use between two or more connectors of different types
3.5.5
standard test adaptor
inter-type adaptor for test purposes, having a standard test connector at one end and a
precision connector at the other end

– 12 – 61169-1 © IEC:2013(E)
3.5.6
standard air line
homogenous air dielectric transmission line having the smallest possible irregularities in
diameter and straightness of conductors, no self-contained supports for the inner conductor
and using non-magnetic material with good conductivity
3.5.7
reference line
air-line similar to the standard air-line but with dielectric support of the inner conductor, and
with a design such that the internal return loss is kept at a minimum within the frequency
range made use of for measurements
3.5.8
proof coupling torque
maximum torque to be applied to the screw-coupling mechanism of a specific connector
series for testing the mechanical strength of the coupling mechanism
3.5.9
normal coupling torque
maximum/minimum values of torque to be applied in normal use to the coupling of screw type
connectors
3.5.10
engagement and separation torque
torque required to overcome friction, compression of springs, etc. during the engagement and
separation of connectors with rotary type coupling mechanisms before or after complete
engagement
Note 1 to entry: This is intended to check for undue tightness of threads, burrs on bayonet-cams, freedom of
rotation of coupling rings, etc.
3.5.11
push-on
connectors with interfaces that engage/disengage in an axial direction
3.6 General electrotechnical terms
3.6.1
nominal value
typical value used to designate or identify a component, device or equipment
Note 1 to entry: It follows from the definition that a nominal value is not subject to tolerances.
Note 2 to entry: Typical and nominal are interchangeable.
3.6.2
limiting value
in a specification, the greatest and/or smallest admissible value of one of the quantities
3.6.3
rated value
operational values that are provided in the detailed specification
4 Units, symbols and dimensions
4.1 Units and symbols
Units, graphical symbols, letter symbols and terminology shall whenever possible, be taken
from the following IEC publications:
60027: Letter symbols to be used in electrical technology.
60050: International Electrotechnical Vocabulary (IEV).
60617: Graphical symbols for diagrams.

61169-1 © IEC:2013(E) – 13 –
Other publication:
ISO 1000: SI units and recommendations for the use of their multiples and of certain other
units.
4.2 Dimensions
4.2.1 Details to be provided in relevant specifications
Each relevant specification shall provide the following.
a) Sufficient dimensional information on the mating faces of connectors should be provided
to ensure intermateability and compliance with performance requirements.
b) Information on the connector envelope maximum dimensions shall be provided to enable
the user to accommodate the connectors in their equipment.
c) The relevant specification is not intended to restrict details of construction which do not
affect interchangeability or performance, nor are they to be used as manufacturing
drawings.
4.2.2 Dimensional units to be used in specifications
The dimensions and tolerances shall be given in metric units.
During conversion of dimensions given in inches into millimetres, they shall, in principle, be
rounded to the nearest 0,001 mm or 0,000 05 in. Where, however, mechanical and electrical
considerations permit, the rounding shall usually be to the nearest 0,01 mm or 0,000 5 in.
5 Standards ratings and characteristics
The ratings and characteristics applicable to each connector type and style shall be stated in
the relevant specification. They should normally cover:
a) a short description of the connector construction stating in particular the inner diameter of
the outer conductor and, if applicable, the preferable cable types to be used with the
connector;
b) the return loss as a function of frequency for the different grades (if applicable) together
with the conditions for which it is valid;
c) the working voltage at different altitudes (pressures);
d) the climatic categories;
e) any other rating or characteristic applicable.
6 Classifications into climatic categories
The classification of connectors with regard to climatic conditions is based on IEC 60068-1
and indicated by a series of three sets of digits separated by oblique strokes corresponding
respectively to tests at low temperature (minus sign not shown), high temperature and the
number of days of exposure to damp heat, steady state.
The climatic severities are referenced by a cold temperature, high temperature and damp heat
steady state duration. Examples of climatic category of this are shown in Table 1:
Table 1 – Preferred climatic categories (see IEC 60068-1)
Category designation Letter Temperature range Damp heat steady state
40/85/21 A 21 days
–40 °C to +85 °C
55/125/21 B 21 days
–55 °C to +125 °C
55/155/56 C 56 days
–55 °C to +155 °C
– 14 – 61169-1 © IEC:2013(E)
7 IEC type designation
The purpose of the IEC type designation is to identify a particular connector within the scope
of IEC r.f. connector standardization. It is not intended to include information in excess of this.
In practice, it is usually necessary to identify a manufacturer's product because, although
complying with the IEC standard, there may be features not covered by the standard.
Connectors complying with the relevant specification shall be designated by the following
indications and in the order given:
a) the number of the specification;
b) the letters "IEC";
c) additional identification as indicated in the relevant specification.
NOTE When an IEC type designation is used, either for the marking of the product or in a description of the
product, it is the responsibility of the manufacturer to ensure that the item meets the requirements of the relevant
specification.
8 Testing
Unless otherwise specified, the following conditions shall apply:
a) tests shall be carried out under standard atmospheric conditions for testing as specified in
IEC 60068-1;
b) before measurements are made, the connectors shall be preconditioned under standard
atmospheric conditions for testing for a time sufficient to allow the entire connector to
reach thermal stability;
c) recovery conditions for the interval after a conditioning and the next measurement of test
shall be in accordance with IEC 60068-1.
The test schedule is shown in 10.3 and details of conditioning in 9.4.1.
When a nominal value only is given for an applied stress and/or the duration of application,
the specified value shall be taken to indicate the minimum test severity to be applied.
The test shall be carried out with connectors – as received from the supplier. In no case shall
the contact parts be cleaned or otherwise prepared prior to tests, unless explicitly stated in
the specification.
If it is required that a cable shall be attached to a connector, this shall be done in accordance
with the connector manufacturer's instructions.
Mated sets of connectors shall be fully engaged and screw-coupled connectors shall be
tightened to the normal coupling torque quoted in the relevant specification.
In the case of mounted connectors subjected to environmental conditioning, care shall be
taken to ensure that the back-of-panel portion of such fixed connectors, when appropriate, is
protected.
For tests involving exposure to extreme temperatures, a cable with appropriate temperature
capability should be used.
9 Test methods
9.1 Mechanical inspection
9.1.1 Visual inspection
Visual inspection shall include a check on
a) the marking: it shall be correct in accordance with 11.1 and be legible after any of the
specified tests;
b) the manufacture: it shall have been carried out in a careful and workmanlike manner;

61169-1 © IEC:2013(E) – 15 –
c) deterioration after electrical, mechanical and climatic tests: unless otherwise specified,
there shall be no visible deterioration likely to affect the performance;
d) the marking on the package: it shall be in accordance with 11.1.
9.1.2 Dimensions
9.1.2.1 General
The dimensions shall be checked and shall comply with those specified by the relevant
specification.
Any suitable method may be used except that gauges shall be used when specified by the
relevant specification.
9.1.2.2 Mechanical compatibility
The dimensions of the mating face shall be in accordance with the mating face drawings
prescribed in the relevant specification. Use of compatibility gauges is optional. When used,
specimens shall accept the gauges.
9.2 Electrical tests and measuring procedures
9.2.1 Return loss
9.2.1.1 General considerations
Return loss is useful for quantifying the level (amount) of the reflected signal due to the
deviation from the nominal impedance and structural effects of the connector, which is useful
when system performance is the primary interest.
The return loss of connectors shall be measured with the test specimen mated with a
standard test connector. Adaptors shall be mated with standard test connectors on both sides.
The relevant specification for a particular connector shall also specify the pertinent standard
test connector (connector of Grade O). Mated pairs of standard test connectors shall exhibit
closest uniformity of characteristic impedance throughout the pair inclusive of the transitions
to precision lines or cables.
Cable connectors shall be attached to an appropriate cable in accordance with the
instructions supplied by the connector manufacturer. The cable to be used shall preferably be
of the close tolerance type.
9.2.1.2 Frequency domain test
9.2.1.2.1 Test equipment
A vector network analyzer (VNA) capable of performing s-parameter measurements using
calibration standards (open, short, load) is recommended.
A vector network analyser is a test system that enables the RF performance of radio
frequency (RF) and microwave devices to be characterised in terms of network scattering
parameters, or S parameters.
The return loss of the connector(s) under test shall be measured with the VNA over the
specified frequency range of interest.
A detailed description of the error correction (calibration) procedure is given in the manual of
the VNA.
Precision test connectors with small inherent reflections (see note below) shall be fitted on
both ends of the test specimen to allow direct connection to the network analyzer, analyzer
test leads and/or, terminating load.
NOTE Small inherent reflections ≤ 1,035:1 VSWR.

– 16 – 61169-1 © IEC:2013(E)
9.2.1.2.2 Procedure
The two-connector procedure uses cable of a known value attached to the connector.
Time domain reflectometry (TDR) shall be used to check the homogeneity of the measuring
set-up, to localize imperfections and to examine the accuracy of the characteristic impedance
of the sections of coaxial lines used.
When available on the network analyser, gating will be performed for removing errors due to
the cable.
The procedure is illustrated in Figures 2 and 3.
The interconnecting cable of the connectors shall consist either of a prescribed cable of
verified performance or an adequate cable simulator.
As a check of the accuracy of the system, it is recommended to repeat the measurements
with the connector assembly reversed between the standard test connectors.
The typical return loss graphical symbols are described in Figure 1:
Time domain reflectometer Mated male and female (pin and socket)

equipment connectors
Frequency domain reflectometer Not necessarily exactly matched

equipment connectors
Precision termination
Mated precision hermaphroditic

connectors
IEC  1631/13
Figur
...


IEC 61169-1 ®
Edition 2.0 2013-07
INTERNATIONAL
STANDARD
NORME
INTERNATIONALE
colour
inside
Radio frequency connectors –
Part 1: Generic specification – General requirements and measuring methods

Connecteurs pour fréquences radioélectriques –
Partie 1: Spécification générique – Exigences générales et méthodes de mesure

All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form
or by any means, electronic or mechanical, including photocopying and microfilm, without permission in writing from
either IEC or IEC's member National Committee in the country of the requester. If you have any questions about IEC
copyright or have an enquiry about obtaining additional rights to this publication, please contact the address below or
your local IEC member National Committee for further information.

Droits de reproduction réservés. Sauf indication contraire, aucune partie de cette publication ne peut être reproduite
ni utilisée sous quelque forme que ce soit et par aucun procédé, électronique ou mécanique, y compris la photocopie
et les microfilms, sans l'accord écrit de l'IEC ou du Comité national de l'IEC du pays du demandeur. Si vous avez des
questions sur le copyright de l'IEC ou si vous désirez obtenir des droits supplémentaires sur cette publication, utilisez
les coordonnées ci-après ou contactez le Comité national de l'IEC de votre pays de résidence.

IEC Central Office Tel.: +41 22 919 02 11
3, rue de Varembé Fax: +41 22 919 03 00
CH-1211 Geneva 20 info@iec.ch
Switzerland www.iec.ch
About the IEC
The International Electrotechnical Commission (IEC) is the leading global organization that prepares and publishes
International Standards for all electrical, electronic and related technologies.

About IEC publications
The technical content of IEC publications is kept under constant review by the IEC. Please make sure that you have the
latest edition, a corrigenda or an amendment might have been published.

IEC Catalogue - webstore.iec.ch/catalogue Electropedia - www.electropedia.org
The stand-alone application for consulting the entire The world's leading online dictionary of electronic and
bibliographical information on IEC International Standards, electrical terms containing 20 000 terms and definitions in
Technical Specifications, Technical Reports and other English and French, with equivalent terms in 15 additional
documents. Available for PC, Mac OS, Android Tablets and languages. Also known as the International Electrotechnical
iPad. Vocabulary (IEV) online.

IEC publications search - www.iec.ch/searchpub IEC Glossary - std.iec.ch/glossary
The advanced search enables to find IEC publications by a 65 000 electrotechnical terminology entries in English and
variety of criteria (reference number, text, technical French extracted from the Terms and Definitions clause of
committee,…). It also gives information on projects, replaced IEC publications issued since 2002. Some entries have been
and withdrawn publications. collected from earlier publications of IEC TC 37, 77, 86 and

CISPR.
IEC Just Published - webstore.iec.ch/justpublished

Stay up to date on all new IEC publications. Just Published IEC Customer Service Centre - webstore.iec.ch/csc
details all new publications released. Available online and If you wish to give us your feedback on this publication or
also once a month by email. need further assistance, please contact the Customer Service
Centre: csc@iec.ch.
A propos de l'IEC
La Commission Electrotechnique Internationale (IEC) est la première organisation mondiale qui élabore et publie des
Normes internationales pour tout ce qui a trait à l'électricité, à l'électronique et aux technologies apparentées.

A propos des publications IEC
Le contenu technique des publications IEC est constamment revu. Veuillez vous assurer que vous possédez l’édition la
plus récente, un corrigendum ou amendement peut avoir été publié.

Catalogue IEC - webstore.iec.ch/catalogue Electropedia - www.electropedia.org
Application autonome pour consulter tous les renseignements
Le premier dictionnaire en ligne de termes électroniques et
bibliographiques sur les Normes internationales,
électriques. Il contient 20 000 termes et définitions en anglais
Spécifications techniques, Rapports techniques et autres
et en français, ainsi que les termes équivalents dans 15
documents de l'IEC. Disponible pour PC, Mac OS, tablettes
langues additionnelles. Egalement appelé Vocabulaire
Android et iPad.
Electrotechnique International (IEV) en ligne.

Recherche de publications IEC - www.iec.ch/searchpub
Glossaire IEC - std.iec.ch/glossary
La recherche avancée permet de trouver des publications IEC 65 000 entrées terminologiques électrotechniques, en anglais
en utilisant différents critères (numéro de référence, texte, et en français, extraites des articles Termes et Définitions des
comité d’études,…). Elle donne aussi des informations sur les publications IEC parues depuis 2002. Plus certaines entrées
projets et les publications remplacées ou retirées. antérieures extraites des publications des CE 37, 77, 86 et

CISPR de l'IEC.
IEC Just Published - webstore.iec.ch/justpublished

Service Clients - webstore.iec.ch/csc
Restez informé sur les nouvelles publications IEC. Just
Published détaille les nouvelles publications parues. Si vous désirez nous donner des commentaires sur cette
Disponible en ligne et aussi une fois par mois par email. publication ou si vous avez des questions contactez-nous:
csc@iec.ch.
IEC 61169-1 ®
Edition 2.0 2013-07
INTERNATIONAL
STANDARD
NORME
INTERNATIONALE
colour
inside
Radio frequency connectors –
Part 1: Generic specification – General requirements and measuring methods

Connecteurs pour fréquences radioélectriques –

Partie 1: Spécification générique – Exigences générales et méthodes de mesure

INTERNATIONAL
ELECTROTECHNICAL
COMMISSION
COMMISSION
ELECTROTECHNIQUE
INTERNATIONALE
ICS 33.120.30 ISBN 978-2-8322-3230-9

– 2 – IEC 61169-1:2013 © IEC:2013
CONTENTS
FOREWORD . 5
1 Scope . 7
2 Normative references . 7
3 Terms and definitions . 8
3.1 General, parts of connectors . 8
3.2 Basic connector terms . 9
3.3 Constructional terms . 10
3.4 Sealing . 11
3.5 Miscellaneous terms . 11
3.6 General electrotechnical terms . 12
4 Units, symbols and dimensions . 12
4.1 Units and symbols . 12
4.2 Dimensions . 13
4.2.1 Details to be provided in relevant specifications . 13
4.2.2 Dimensional units to be used in specifications . 13
5 Standards ratings and characteristics . 13
6 Classifications into climatic categories . 13
7 IEC type designation . 14
8 Testing . 14
9 Test methods . 14
9.1 Mechanical inspection. 14
9.1.1 Visual inspection . 14
9.1.2 Dimensions . 15
9.2 Electrical tests and measuring procedures . 15
9.2.1 Return loss . 15
9.2.2 Power rating . 19
9.2.3 Contact resistance, outer conductor and centre conductor continuity
(mated cabled connectors) . 20
9.2.4 Centre and outer conductor contact continuity under severe
mechanical conditioning . 22
9.2.5 Insulation resistance . 22
9.2.6 Voltage proof . 23
9.2.7 Screening effectiveness . 24
9.2.8 Discharge test (corona test) . 24
9.2.9 Intermodulation level (PIM). 25
9.2.10 Surge withstand . 26
9.3 Mechanical tests and measuring procedures . 26
9.3.1 General . 26
9.3.2 Soldering . 26
9.3.3 Vibration . 26
9.3.4 Insertion force (resilient contacts) . 27
9.3.5 Centre contact captivation . 28
9.3.6 Engagement and separation forces and torques . 28
9.3.7 Effectiveness of clamping device against cable rotation (nutation of
cable end) . 29
9.3.8 Effectiveness of clamping device against cable pulling . 29

9.3.9 Effectiveness of clamping device against cable bending . 30
9.3.10 Effectiveness of clamping device against cable torsion . 31
9.3.11 Strength of coupling mechanism . 32
9.3.12 Safety wire hole pull-out bending moment (and shearing force) . 32
9.3.13 Bump . 33
9.3.14 Shock . 34
9.3.15 Mechanical endurance . 35
9.4 Climatic conditionings and tests . 35
9.4.1 Conditionings . 35
9.4.2 Climatic sequence . 36
9.4.3 Damp heat, steady state . 37
9.4.4 Change of temperature . 37
9.4.5 High temperature endurance . 38
9.4.6 Low temperature endurance . 39
9.4.7 Sealing non-hermetic sealed connectors . 40
9.4.8 Hermetically sealed connectors . 40
9.4.9 Water immersion test . 41
9.4.10 Salt mist . 43
9.4.11 Resistance to solvents and contaminating fluids . 43
9.4.12 Sulphur dioxide test . 45
10 Quality assessment . 46
10.1 General . 46
10.2 Quality assessment steps . 46
10.2.1 Primary stage of manufacture . 46
10.2.2 Structurally similar components . 46
10.2.3 General principle for obtaining quality conformance . 46
10.3 Test schedule and inspection requirements . 46
10.3.1 Acceptance tests. 46
10.3.2 Periodic tests . 48
10.4 Procedures for quality conformance . 49
10.4.1 Quality conformance inspection . 49
10.4.2 Quality conformance and its maintenance . 49
10.5 Test and measurement procedures . 49
10.5.1 General . 49
10.5.2 Schedule of basic test groupings for acceptance and periodic tests . 50
10.6 Specifications . 50
10.6.1 Specification structures . 50
10.6.2 Sectional specification (SS) . 50
10.6.3 Detail specification (DS) . 50
10.6.4 Blank detail specification . 51
10.6.5 Blank detail specification pro-forma for XXXX connectors . 52
11 Marking . 57
11.1 Marking of component . 57
11.2 Marking and contents of package . 57
Annex A (informative) Simulated sea-water solution for use with salt mist test (marine
environment, see 9.4.10.3) . 58
Bibliography . 59

– 4 – IEC 61169-1:2013 © IEC:2013
Figure 1 – graphical symbols . 16
Figure 2 – General principle . 16
Figure 3 – Measuring set-up for two-connector procedure . 17
Figure 4 – Example of a time domain reflectometer measurement recording . 18
Figure 5 – Equipment set-up for the measurement of reflection in time domain . 19
Figure 6 – Possible test arrangements . 23
Figure 7 – Measuring circuit for the discharge test . 25
Figure 8 – Test arrangement for nutation . 29
Figure 9 – Test arrangement for pulling . 30
Figure 10 – Bending . 31
Figure 11 – Cable torsion . 31
Figure 12 – Temperature curve profile . 41
Figure 13 – Container/jumper arrangement . 42

Table 1 – Preferred climatic categories (see IEC 60068-1) . 13
Table 2 – Dielectric materials ratings . 20
Table 3 – Severities for vibration . 27
Table 4 – Recommended severities for bump . 33
Table 5 – Recommended severities for shocks . 34
Table 6 – Recommended severities for low temperature tests . 39
Table 7 – Fuels, lubricants, hydraulic fluids and anti-freeze agents . 44
Table 8 – Cleaning agents and moisture repellents . 44
Table 9 – Acceptance tests . 47
Table 10 – Periodic tests . 48

INTERNATIONAL ELECTROTECHNICAL COMMISSION
____________
RADIO FREQUENCY CONNECTORS –
Part 1: Generic specification –
General requirements and measuring methods

FOREWORD
1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of IEC is to promote
international co-operation on all questions concerning standardization in the electrical and electronic fields. To
this end and in addition to other activities, IEC publishes International Standards, Technical Specifications,
Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC
Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested
in the subject dealt with may participate in this preparatory work. International, governmental and non-
governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely
with the International Organization for Standardization (ISO) in accordance with conditions determined by
agreement between the two organizations.
2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international
consensus of opinion on the relevant subjects since each technical committee has representation from all
interested IEC National Committees.
3) IEC Publications have the form of recommendations for international use and are accepted by IEC National
Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC
Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any
misinterpretation by any end user.
4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications
transparently to the maximum extent possible in their national and regional publications. Any divergence
between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in
the latter.
5) IEC itself does not provide any attestation of conformity. Independent certification bodies provide conformity
assessment services and, in some areas, access to IEC marks of conformity. IEC is not responsible for any
services carried out by independent certification bodies.
6) All users should ensure that they have the latest edition of this publication.
7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and
members of its technical committees and IEC National Committees for any personal injury, property damage or
other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and
expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC
Publications.
8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is
indispensable for the correct application of this publication.
9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of
patent rights. IEC shall not be held responsible for identifying any or all such patent rights.
International Standard IEC 61169-1 has been prepared by subcommittee 46F: R.F. and
microwave passive components, of IEC technical committee 46: Cables, wires, waveguides,
R.F. connectors, R.F. and microwave passive components and accessories.
This second edition cancels and replaces the first edition, published in 1992, its Amendments
1 (1996) and 2 (1997). This edition constitutes a technical revision.
With respect to the previous edition, tests methods have been updated as well as terminology.
This bilingual version (2016-03) corresponds to the monolingual English version, published in
2013-07.
– 6 – IEC 61169-1:2013 © IEC:2013
The text of this standard is based on the following documents:
CDV Report on voting
46F/216/CDV 46F/226/RVC
Full information on the voting for the approval of this standard can be found in the report on
voting indicated in the above table.
The French version of this standard has not been voted upon.
This publication has been drafted in accordance with the ISO/IEC Directives, Part 2.
A list of all the parts in the IEC 61169 series, published under the general title Radio
frequency connectors, can be found on the IEC website.
The committee has decided that the contents of this publication will remain unchanged until
the stability date indicated on the IEC web site under "http://webstore.iec.ch" in the data
related to the specific publication. At this date, the publication will be
• reconfirmed,
• withdrawn,
• replaced by a revised edition, or
• amended.
IMPORTANT – The 'colour inside' logo on the cover page of this publication indicates
that it contains colours which are considered to be useful for the correct
understanding of its contents. Users should therefore print this document using a
colour printer.
RADIO FREQUENCY CONNECTORS –
Part 1: Generic specification –
General requirements and measuring methods

1 Scope
This part of IEC 61169, which is a generic specification, relates to radio frequency connectors
for r.f. transmission lines for use in telecommunications, electronics and similar equipment.
It provides the basis for the sectional standards, which apply to individual connector types. It
is intended to establish uniform concepts and procedures concerning:
– terminology;
– standard ratings and characteristics;
– testing and measuring procedures concerning electrical, mechanical and climatic
properties;
– classification of connectors with regard to climatic testing procedures involving
temperature and humidity.
The test methods and procedures of this standard are intended for acceptance and type
approval testing.
2 Normative references
The following documents, in whole or in part, are normatively referenced in this document and
are indispensable for its application. For dated references, only the edition cited applies. For
undated references, the latest edition of the referenced document (including any
amendments) applies.
IEC 60027 (all parts), Letter symbols to be used in electrical technology
IEC 60050 (all parts), International Electrotechnical Vocabulary (available from:
http://www.electropedia.org)
IEC 60068-1, Environmental testing – Part 1: General and guidance
IEC 60068-2-1:1990, Environmental testing – Part 2-1: Tests – Test A: Cold
IEC 60068-2-2:1974, Environmental testing – Part 2-2: Tests – Test B: Dry heat
IEC 60068-2-6, Environmental testing – Part 2-6: Tests – Test Fc: Vibration (sinusoidal)
IEC 60068-2-11, Environmental testing – Part 2-11: Tests – Test Ka: Salt mist
IEC 60068-2-13, Environmental testing – Part 2-13: Tests – Test M: Low air pressure
IEC 60068-2-14:2009, Environmental testing – Part 2-14: Tests – Test N: Change of
temperature
IEC 60068-2-17, Environmental testing – Part 2-17: Tests – Test Q: Sealing
_____________
This publication has been withdrawn.
This publication has been withdrawn.

– 8 – IEC 61169-1:2013 © IEC:2013
IEC 60068-2-20, Environmental testing – Part 2-20: Tests – Test T: Test methods for
solderability and resistance to soldering heat of devices with leads
IEC 60068-2-27, Environmental testing – Part 2-27: Tests – Test Ea and guidance: Shock
IEC 60068-2-29, Environmental testing – Part 2: Tests – Test Eb and guidance: Bump
IEC 60068-2-30, Environmental testing – Part 2-30: Tests – Test Db: Damp heat, cyclic (12 h
+ 12 h cycle)
IEC 60068-2-42, Environmental testing – Part 2-42: Tests – Test Kc: Sulphur dioxide test for
contacts and connections
IEC 60068-2-52:1996, Environmental testing – Test Kb: Salt mist, cyclic (sodium, chloride
solution)
IEC 60068-2-54, Environmental testing – Part 2-54: Tests – Test Ta: Solderability testing of
electronic components by the wetting balance method
IEC 60068-2-61:1991, Environmental testing – Part 2-61: Test methods – Test Z/ABDM:
Climatic sequence
IEC 60068-2-78, Environmental testing – Part 2-78: Tests – Test Cab: Damp heat, steady
state
IEC 60457-1, Rigid precision coaxial lines and their associated precision connectors – Part 1:
General requirements and measuring methods
IEC 60617, Graphical symbols for diagrams (available from: http://std.iec.ch/iec60617)
IEC 62153 (all parts), Metallic communication cables test methods
IEC 61726, Cable assemblies, cables, connectors and passive microwave components –
Screening attenuation measurement by the reverberation chamber method
IEC 62037 (all parts), Passive RF and microwave devices, intermodulation level measurement
ISO 1000, SI units and recommendations for the use of their multiples and of certain other
units
3 Terms and definitions
For the purposes of this document, the following terms and definitions apply.
NOTE Some of the terms defined are not used in the present document, but may be used in the different sectional
specifications.
3.1 General, parts of connectors
3.1.1
contact (electrical)
state in which individual electrically conductive parts are in such close mechanical touch as to
provide a low resistance path to electrical current in either direction
3.1.2
contact
a component which mates with a corresponding element to provide an
conductive element in
electrical path (to provide electrical contact)
_____________
This publication has been withdrawn.

3.1.3
male (pin) contact
contact intended to make electrical engagement on its outer surface and which will enter a
female (socket) contact
3.1.4
female (socket) contact
contact intended to make electrical engagement on its inner surface and which will accept
entry of a male (pin) contact
3.1.5
hermaphroditic contact
contact which is intended to mate with an identical contact
3.1.6
resilient contact
contact having elastic properties to provide a force to its mating part
3.2 Basic connector terms
3.2.1
connector
component normally attached to a cable or mounted on a piece of apparatus (excluding an
adaptor) for electrically joining separable parts of a transmission line system
3.2.2
connector pair
two connectors having complementary mating faces and locking means, so as to be mateable
and interlockable
3.2.3
series type
terms characterizing the particular mating faces and locking means of a connector pair with
regard to construction and dimension
Note 1 to entry: The term "series" is sometimes used as an approximate synonym of 'type' for designating the
entirety of connector styles with identical mating face and locking means.
3.2.4
style
particular form or shape of connector, as well as a combination of connectors of the same
type
Note 1 to entry: For "adaptor", see 3.5.1 to 3.5.5: a 'within-type adaptor" may also be considered as a particular
style of a given type.
Note 2 to entry: Examples are: free and fixed connectors, both straight and right angle, within-type adaptors
straight and right angle.
3.2.5
variant
variation of a style, in particular details, such as cable-entry dimensions
3.2.6
grade
qualification of a connector with regard to mechanical and electrical precision in particular
with respect to a defined return loss
3.2.7
general purpose connector: Grade 2
connector making use of the widest permitted dimensional deviations (tolerances) so as still
to guarantee minimum stated performance and intermateability
Note 1 to entry: A requirement for the return loss may or may not be specified.

– 10 – IEC 61169-1:2013 © IEC:2013
3.2.8
high performance connector: Grade 1
connector for which limits of return loss are specified as a function of frequency.
Note 1 to entry: No tighter dimensional tolerances than those applicable to Grade 2 are normally specified. The
manufacturer is responsible, however, for choosing tighter tolerances where necessary to ensure that the return
loss requirements are met.
3.2.9
standard test connector: Grade 0
precisely made connector of a particular type used to carry out return loss measurements on
Grade 1 and Grade 2 connectors, contributing only negligible errors to the measuring result
Note 1 to entry: The standard test connector is often part of an inner-type adaptor which allows connection with a
precision connector forming part of the measuring equipment.
3.2.10
precision connector
connector that has coincident mechanical and electrical reference planes, air dielectric, and
has the property of making connections with a high degree of repeatability without introducing
significant reflections, loss or leakage
Note 1 to entry: It is intended for mounting on air-lines and instruments. Precision connectors can be of the
hermaphroditic type, flange type or of the pin and socket type as stated in IEC 60457-1.
3.2.11
laboratory precision connector
LPC
precision connector without dielectric support for the centre conductor
3.2.12
general precision connector
GPC
precision connector with self-contained dielectric support capable of supporting the un-
supported centre conductor of an LPC and standard air-line which it is mated
3.3 Constructional terms
3.3.1
male connector/pin connector
connector containing a male (pin) centre contact
3.3.2
female connector/socket connector
connector containing a female (socket) centre contact
3.3.3
plug connector
connector featuring the active part of the coupling mechanism, i.e. the nut or bayonet ring,
and which normally is a free contact
Note 1 to entry: Depending on the particular type, a plug may be a male or female connector.
3.3.4
socket
connector complimentary to the plug
3.3.5
hermaphroditic connector
connector which mates with an identical connector
3.3.6
free connector
connector for attachment to a free end of a cable
Note 1 to entry: If not specified as fixed, a connector is assumed to be free.

3.3.7
fixed connector
connector with provision for attachment to a mounting surface
3.3.8
triaxial
transmission line comprising three concentric conductors having a common axis and with
each conductor insulated from the other two
3.4 Sealing
3.4.1
sealed connector
connector employing a seal capable of fulfilling specified gas-, moisture- or liquid tightness
requirements
3.4.2
barrier seal
seal preventing the passage of gases, moisture or liquids in an axial direction within the body
shell of a connector
3.4.3
panel seal
seal preventing the passage of gases, moisture or liquids between the fixed connector or
adaptor body shell and the panel via the mounting hole(s)
Note 1 to entry: The sealing member is often provided as a discrete item.
3.4.4
mating face seal
seal preventing the passage of gases, moisture or liquids into the interface space of a pair of
mated connectors
3.4.5
hermetic seal
seal meeting the requirements specified on application of Test Qk of IEC 60068-2-17
3.5 Miscellaneous terms
3.5.1
adaptor
two-port device for joining two transmission lines having non-mating connectors
3.5.2
fixed adaptor
adaptor with provision for attachment to a mounting surface
Note 1 to entry: If not specified as fixed, an adaptor is assumed to be free.
3.5.3
within-type adaptor
adaptor for use between two or more connectors all of the same type
3.5.4
inter-type adaptor
adaptor for use between two or more connectors of different types
3.5.5
standard test adaptor
inter-type adaptor for test purposes, having a standard test connector at one end and a
precision connector at the other end

– 12 – IEC 61169-1:2013 © IEC:2013
3.5.6
standard air line
homogenous air dielectric transmission line having the smallest possible irregularities in
diameter and straightness of conductors, no self-contained supports for the inner conductor
and using non-magnetic material with good conductivity
3.5.7
reference line
air-line similar to the standard air-line but with dielectric support of the inner conductor, and
with a design such that the internal return loss is kept at a minimum within the frequency
range made use of for measurements
3.5.8
proof coupling torque
maximum torque to be applied to the screw-coupling mechanism of a specific connector
series for testing the mechanical strength of the coupling mechanism
3.5.9
normal coupling torque
maximum/minimum values of torque to be applied in normal use to the coupling of screw type
connectors
3.5.10
engagement and separation torque
torque required to overcome friction, compression of springs, etc. during the engagement and
separation of connectors with rotary type coupling mechanisms before or after complete
engagement
Note 1 to entry: This is intended to check for undue tightness of threads, burrs on bayonet-cams, freedom of
rotation of coupling rings, etc.
3.5.11
push-on
connectors with interfaces that engage/disengage in an axial direction
3.6 General electrotechnical terms
3.6.1
nominal value
typical value used to designate or identify a component, device or equipment
Note 1 to entry: It follows from the definition that a nominal value is not subject to tolerances.
Note 2 to entry: Typical and nominal are interchangeable.
3.6.2
limiting value
in a specification, the greatest and/or smallest admissible value of one of the quantities
3.6.3
rated value
operational values that are provided in the detailed specification
4 Units, symbols and dimensions
4.1 Units and symbols
Units, graphical symbols, letter symbols and terminology shall whenever possible, be taken
from the following IEC publications:
60027: Letter symbols to be used in electrical technology.
60050: International Electrotechnical Vocabulary (IEV).
60617: Graphical symbols for diagrams.

Other publication:
ISO 1000: SI units and recommendations for the use of their multiples and of certain other
units.
4.2 Dimensions
4.2.1 Details to be provided in relevant specifications
Each relevant specification shall provide the following.
a) Sufficient dimensional information on the mating faces of connectors should be provided
to ensure intermateability and compliance with performance requirements.
b) Information on the connector envelope maximum dimensions shall be provided to enable
the user to accommodate the connectors in their equipment.
c) The relevant specification is not intended to restrict details of construction which do not
affect interchangeability or performance, nor are they to be used as manufacturing
drawings.
4.2.2 Dimensional units to be used in specifications
The dimensions and tolerances shall be given in metric units.
During conversion of dimensions given in inches into millimetres, they shall, in principle, be
rounded to the nearest 0,001 mm or 0,000 05 in. Where, however, mechanical and electrical
considerations permit, the rounding shall usually be to the nearest 0,01 mm or 0,000 5 in.
5 Standards ratings and characteristics
The ratings and characteristics applicable to each connector type and style shall be stated in
the relevant specification. They should normally cover:
a) a short description of the connector construction stating in particular the inner diameter of
the outer conductor and, if applicable, the preferable cable types to be used with the
connector;
b) the return loss as a function of frequency for the different grades (if applicable) together
with the conditions for which it is valid;
c) the working voltage at different altitudes (pressures);
d) the climatic categories;
e) any other rating or characteristic applicable.
6 Classifications into climatic categories
The classification of connectors with regard to climatic conditions is based on IEC 60068-1
and indicated by a series of three sets of digits separated by oblique strokes corresponding
respectively to tests at low temperature (minus sign not shown), high temperature and the
number of days of exposure to damp heat, steady state.
The climatic severities are referenced by a cold temperature, high temperature and damp heat
steady state duration. Examples of climatic category of this are shown in Table 1:
Table 1 – Preferred climatic categories (see IEC 60068-1)
Category designation Letter Temperature range Damp heat steady state
40/85/21 A 21 days
–40 °C to +85 °C
55/125/21 B 21 days
–55 °C to +125 °C
55/155/56 C 56 days
–55 °C to +155 °C
– 14 – IEC 61169-1:2013 © IEC:2013
7 IEC type designation
The purpose of the IEC type designation is to identify a particular connector within the scope
of IEC r.f. connector standardization. It is not intended to include information in excess of this.
In practice, it is usually necessary to identify a manufacturer's product because, although
complying with the IEC standard, there may be features not covered by the standard.
Connectors complying with the relevant specification shall be designated by the following
indications and in the order given:
a) the number of the specification;
b) the letters "IEC";
c) additional identification as indicated in the relevant specification.
NOTE When an IEC type designation is used, either for the marking of the product or in a description of the
product, it is the responsibility of the manufacturer to ensure that the item meets the requirements of the relevant
specification.
8 Testing
Unless otherwise specified, the following conditions shall apply:
a) tests shall be carried out under standard atmospheric conditions for testing as specified in
IEC 60068-1;
b) before measurements are made, the connectors shall be preconditioned under standard
atmospheric conditions for testing for a time sufficient to allow the entire connector to
reach thermal stability;
c) recovery conditions for the interval after a conditioning and the next measurement of test
shall be in accordance with IEC 60068-1.
The test schedule is shown in 10.3 and details of conditioning in 9.4.1.
When a nominal value only is given for an applied stress and/or the duration of application,
the specified value shall be taken to indicate the minimum test severity to be applied.
The test shall be carried out with connectors – as received from the supplier. In no case shall
the contact parts be cleaned or otherwise prepared prior to tests, unless explicitly stated in
the specification.
If it is required that a cable shall be attached to a connector, this shall be done in accordance
with the connector manufacturer's instructions.
Mated sets of connectors shall be fully engaged and screw-coupled connectors shall be
tightened to the normal coupling torque quoted in the relevant specification.
In the case of mounted connectors subjected to environmental conditioning, care shall be
taken to ensure that the back-of-panel portion of such fixed connectors, when appropriate, is
protected.
For tests involving exposure to extreme temperatures, a cable with appropriate temperature
capability should be used.
9 Test methods
9.1 Mechanical inspection
9.1.1 Visual inspection
Visual inspection shall include a check on
a) the marking: it shall be correct in accordance with 11.1 and be legible after any of the
specified tests;
b) the manufacture: it shall have been carried out in a careful and workmanlike manner;

c) deterioration after electrical, mechanical and climatic tests: unless otherwise specified,
there shall be no visible deterioration likely to affect the performance;
d) the marking on the package: it shall be in accordance with 11.1.
9.1.2 Dimensions
9.1.2.1 General
The dimensions shall be check
...