General Information

Abstract

IEC 61169-43:2013, which is a sectional specification (SS), provides information and rules for the preparation of detail specifications (DS) for RBMA series RF coaxial connectors, with characteristic impedance of 50 Ω, with threaded coupling and operating frequency limit up to 12,4 GHz, used in wireless, microwave, telecommunication, and other fields, connecting with RF cables or micro-strips. It also prescribes mating face dimensions for general connectors-grade 2, dimensional details of standard test connectors-grade 0, gauging information and tests selected from IEC 61169-1, applicable to all detail specifications relating to RBMA series connectors. This specification indicates the recommended performance characteristics to be considered when writing a detail specification and it covers test schedules and inspection requirements for assessment levels M and H (see Tables 8 and 9).

Status
Published
Publication Date
19-Mar-2013
Current Stage
PPUB - Publication issued
Start Date
20-Mar-2013
Completion Date
15-Apr-2013

Buy Documents

Standard

IEC 61169-43:2013 - Radio-frequency connectors - Part 43: Sectional specification for RBMA series blind mating RF coaxial connectors Released:3/20/2013

ISBN:978-2-8322-0687-4
English language (28 pages)
sale 15% off
Preview
sale 15% off
Preview
Standard

IEC 61169-43:2013 - Radio-frequency connectors - Part 43: Sectional specification for RBMA series blind mating RF coaxial connectors Released:3/20/2013

ISBN:978-2-8322-1316-2
English and French language (58 pages)
sale 15% off
Preview
sale 15% off
Preview

Overview - IEC 61169-43:2013 (RBMA series blind mating RF coaxial connectors)

IEC 61169-43:2013 is a sectional specification that provides rules and guidance for preparing detail specifications (DS) for RBMA series blind mating RF coaxial connectors. The standard applies to 50 Ω threaded-coupling connectors with an operating frequency limit up to 12.4 GHz, intended for connections to RF cables or micro‑strips in wireless, microwave and telecommunication equipment. It complements the generic requirements in IEC 61169-1 by prescribing mating-face dimensions, gauging, test schedules and inspection requirements specific to the RBMA series.

Key technical topics and requirements

  • Connector family and electrical rating
    • RBMA series, characteristic impedance 50 Ω, threaded coupling, operating frequency up to 12.4 GHz.
  • Mating-face and gauge information
    • Mating face dimensions for general connectors - Grade 2 and dimensional details of standard test connectors - Grade 0.
    • Gauges: detailed gauge pin geometry and two gauge types (A and B) with dimensional limits and surface-finish requirements (e.g., mass of gauge ~28 g ±2 g; surface roughness Ra ≤ 0.4 μm).
    • Example retention requirement: gauge B must have a withdrawal force ≥ 0.28 N after specified sizing procedure.
  • Mechanical limits and mounting
    • Limits for radial and axial misalignment, floating vs. rigid mounting, and reference planes for mating interfaces.
  • Quality assessment & tests
    • Selection of tests from IEC 61169-1, recommended performance characteristics, and prescribed acceptance (M) and periodic (H) test schedules (see Tables 8 and 9 in the standard).
    • Procedures for quality conformance inspection, qualification approval and maintenance.
  • Guidance for DS authors
    • Instructions and a blank pro‑forma to prepare detail specifications including identification, performance, marking and test severities.

Practical applications and who uses this standard

  • Typical applications: wireless base stations, microwave modules, telecom RF front-ends, and any system requiring blind‑mating RF interfaces in modular panels and racks.
  • Primary users:
    • Connector manufacturers and design engineers preparing detail specifications.
    • Quality and test laboratories performing mating/gauging, retention and electrical/mechanical tests.
    • Procurement and compliance teams specifying connector acceptance criteria.
    • System integrators and RF designers concerned with mating tolerances and reliable blind mating.

Related standards

  • IEC 61169-1: Generic specification - general requirements and measuring methods (normative reference).
  • Other parts of the IEC 61169 series cover different RF connector families and additional test methods.

Practical takeaway: IEC 61169-43 helps ensure interoperable, reliable RBMA blind‑mating RF connectors by standardizing critical mating dimensions, gauging methods and test schedules - essential for manufacturers, test labs and system designers working at RF up to 12.4 GHz.

Relations

Effective Date
05-Sep-2023

Buy Documents

Standard

IEC 61169-43:2013 - Radio-frequency connectors - Part 43: Sectional specification for RBMA series blind mating RF coaxial connectors Released:3/20/2013

ISBN:978-2-8322-0687-4
English language (28 pages)
sale 15% off
Preview
sale 15% off
Preview
Standard

IEC 61169-43:2013 - Radio-frequency connectors - Part 43: Sectional specification for RBMA series blind mating RF coaxial connectors Released:3/20/2013

ISBN:978-2-8322-1316-2
English and French language (58 pages)
sale 15% off
Preview
sale 15% off
Preview

Get Certified

Connect with accredited certification bodies for this standard

ANCE

Mexican certification and testing association.

EMA Mexico Verified

Intertek Slovenia

Intertek testing, inspection, and certification services in Slovenia.

UKAS Slovenia Verified

LNE (Laboratoire National de Métrologie et d'Essais)

French national laboratory for metrology and testing.

COFRAC France Verified

Sponsored listings

Frequently Asked Questions

IEC 61169-43:2013 is a standard published by the International Electrotechnical Commission (IEC). Its full title is "Radio-frequency connectors - Part 43: Sectional specification for RBMA series blind mating RF coaxial connectors". This standard covers: IEC 61169-43:2013, which is a sectional specification (SS), provides information and rules for the preparation of detail specifications (DS) for RBMA series RF coaxial connectors, with characteristic impedance of 50 Ω, with threaded coupling and operating frequency limit up to 12,4 GHz, used in wireless, microwave, telecommunication, and other fields, connecting with RF cables or micro-strips. It also prescribes mating face dimensions for general connectors-grade 2, dimensional details of standard test connectors-grade 0, gauging information and tests selected from IEC 61169-1, applicable to all detail specifications relating to RBMA series connectors. This specification indicates the recommended performance characteristics to be considered when writing a detail specification and it covers test schedules and inspection requirements for assessment levels M and H (see Tables 8 and 9).

IEC 61169-43:2013, which is a sectional specification (SS), provides information and rules for the preparation of detail specifications (DS) for RBMA series RF coaxial connectors, with characteristic impedance of 50 Ω, with threaded coupling and operating frequency limit up to 12,4 GHz, used in wireless, microwave, telecommunication, and other fields, connecting with RF cables or micro-strips. It also prescribes mating face dimensions for general connectors-grade 2, dimensional details of standard test connectors-grade 0, gauging information and tests selected from IEC 61169-1, applicable to all detail specifications relating to RBMA series connectors. This specification indicates the recommended performance characteristics to be considered when writing a detail specification and it covers test schedules and inspection requirements for assessment levels M and H (see Tables 8 and 9).

IEC 61169-43:2013 is classified under the following ICS (International Classification for Standards) categories: 33.120.30 - RF connectors. The ICS classification helps identify the subject area and facilitates finding related standards.

IEC 61169-43:2013 has the following relationships with other standards: It is inter standard links to IEC PAS 61169-43:2010. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.

IEC 61169-43:2013 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.

Standards Content (Sample)


IEC 61169-43 ®
Edition 1.0 2013-03
INTERNATIONAL
STANDARD
colour
inside
Radio-frequency connectors –
Part 43: Sectional specification for RBMA series blind mating RF coaxial
connectors
All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form
or by any means, electronic or mechanical, including photocopying and microfilm, without permission in writing from
either IEC or IEC's member National Committee in the country of the requester.
If you have any questions about IEC copyright or have an enquiry about obtaining additional rights to this publication,
please contact the address below or your local IEC member National Committee for further information.

IEC Central Office Tel.: +41 22 919 02 11
3, rue de Varembé Fax: +41 22 919 03 00
CH-1211 Geneva 20 info@iec.ch
Switzerland www.iec.ch
About the IEC
The International Electrotechnical Commission (IEC) is the leading global organization that prepares and publishes
International Standards for all electrical, electronic and related technologies.

About IEC publications
The technical content of IEC publications is kept under constant review by the IEC. Please make sure that you have the
latest edition, a corrigenda or an amendment might have been published.

Useful links:
IEC publications search - www.iec.ch/searchpub Electropedia - www.electropedia.org
The advanced search enables you to find IEC publications The world's leading online dictionary of electronic and
by a variety of criteria (reference number, text, technical electrical terms containing more than 30 000 terms and
committee,…). definitions in English and French, with equivalent terms in
It also gives information on projects, replaced and additional languages. Also known as the International
withdrawn publications. Electrotechnical Vocabulary (IEV) on-line.

IEC Just Published - webstore.iec.ch/justpublished Customer Service Centre - webstore.iec.ch/csc
Stay up to date on all new IEC publications. Just Published If you wish to give us your feedback on this publication
details all new publications released. Available on-line and or need further assistance, please contact the
also once a month by email. Customer Service Centre: csc@iec.ch.

IEC 61169-43 ®
Edition 1.0 2013-03
INTERNATIONAL
STANDARD
colour
inside
Radio-frequency connectors –
Part 43: Sectional specification for RBMA series blind mating RF coaxial

connectors
INTERNATIONAL
ELECTROTECHNICAL
COMMISSION
PRICE CODE
U
ICS 33.120.30 ISBN 978-2-83220-687-4

– 2 – 61169-43 © IEC:2013(E)
CONTENTS
FOREWORD . 4
1 Scope . 6
2 Normative references . 6
3 Mating face and gauge information . 6
3.1 Dimensions – General connectors – Grade 2 . 6
3.1.1 Connector with pin-centre contact . 6
3.1.2 Connector with socket-centre contact . 8
3.2 Gauges . 9
3.2.1 Gauge pin for socket-centre contact . 9
3.2.2 Gauge for outer contact of connector with pin-centre contact . 10
3.3 Dimensions – Standard test connectors – Grade 0 . 11
3.3.1 Connector with pin-centre contact . 11
3.3.2 Connector with socket-centre contact . 12
3.4 General requirements for connector mounting in modules and on panels . 13
3.4.1 Limits of permissible connector radial misalignment and axial
misalignment . 13
3.4.2 Specific connector mounting details . 16
4 Quality assessment procedure . 16
4.1 General . 16
4.2 Rating and characteristics (see Clause 6 of IEC 61169-1:1992) . 17
4.3 Test schedule and inspection requirements . 20
4.3.1 Acceptance tests . 20
4.3.2 Periodic tests. 21
4.4 Procedures . 22
4.4.1 Quality conformance inspection . 22
4.4.2 Qualification approval and its maintenance . 22
5 Instructions for preparation of detail specifications . 23
5.1 General . 23
5.2 Identification of the component . 23
5.3 Performance . 23
5.4 Marking, ordering information and related matters . 23
5.5 Selection of tests, test conditions and severities . 23
5.6 Blank detail specification pro-forma for series RBMA connectors . 24

Figure 1 – Connector with pin- centre contact . 7
Figure 2 – Connector with socket-centre contact . 8
Figure 3 – Gauge pin for socket-centre contact . 9
Figure 4 – Gauge for outer contact of connector with pin-centre contact . 10
Figure 5 – Connector with pin-centre contact (G0) . 11
Figure 6 – Connector with socket-centre contact . 12
Figure 7 – Rigidly mounted connector with socket-centre contact and rigidly mounted
connector with pin-centre contact radial misalignment limits . 14
Figure 8 – Rigidly mounted connector with socket-centre contact and float-mounted
connector with pin-centre contact radial misalignment limits . 14
Figure 9 – Floating connector self-aligned . 15
Figure 10 – Separation between the two reference planes . 16

61169-43 © IEC:2013(E) – 3 –
Figure 11 – Axial misalignment limits . 16

Table 1 – Dimensions of connector with pin-centre contact . 7
Table 2 – Dimensions of connector with socket-centre contact . 8
Table 3 – Dimensions of gauge pin for socket-centre contact . 9
Table 4 – Gauge for outer contact of connector with pin-centre contact . 10
Table 5 – Dimensions of connector with pin-centre contact (G0) . 12
Table 6 – Dimensions of connector with socket-centre contact . 13
Table 7 – Rating and characteristics . 17
Table 8 – Acceptance tests . 20
Table 9 – Periodic tests . 21

– 4 – 61169-43 © IEC:2013(E)
INTERNATIONAL ELECTROTECHNICAL COMMISSION
____________
RADIO-FREQUENCY CONNECTORS –
Part 43: Sectional specification for RBMA series
blind mating RF coaxial connectors

FOREWORD
1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of IEC is to promote
international co-operation on all questions concerning standardization in the electrical and electronic fields. To
this end and in addition to other activities, IEC publishes International Standards, Technical Specifications,
Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC
Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested
in the subject dealt with may participate in this preparatory work. International, governmental and non-
governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely
with the International Organization for Standardization (ISO) in accordance with conditions determined by
agreement between the two organizations.
2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international
consensus of opinion on the relevant subjects since each technical committee has representation from all
interested IEC National Committees.
3) IEC Publications have the form of recommendations for international use and are accepted by IEC National
Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC
Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any
misinterpretation by any end user.
4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications
transparently to the maximum extent possible in their national and regional publications. Any divergence
between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in
the latter.
5) IEC itself does not provide any attestation of conformity. Independent certification bodies provide conformity
assessment services and, in some areas, access to IEC marks of conformity. IEC is not responsible for any
services carried out by independent certification bodies.
6) All users should ensure that they have the latest edition of this publication.
7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and
members of its technical committees and IEC National Committees for any personal injury, property damage or
other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and
expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC
Publications.
8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is
indispensable for the correct application of this publication.
9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of
patent rights. IEC shall not be held responsible for identifying any or all such patent rights.
International Standard IEC 61169-43 has been prepared by subcommittee 46F: R.F. and
microwave passive components, of IEC technical committee 46: Cables, wires, waveguides,
R.F. connectors, R.F. and microwave passive components and accessories.
This first edition cancels and replaces IEC/PAS 61169-43 published in 2010. This edition
constitutes a technical revision.
The text of this standard is based on the following documents:
FDIS Report on voting
46F/221/FDIS 46F/227/RVD
Full information on the voting for the approval of this standard can be found in the report on
voting indicated in the above table.
This publication has been drafted in accordance with the ISO/IEC Directives, Part 2.

61169-43 © IEC:2013(E) – 5 –
A list of all the parts in the IEC 61169 series, published under the general title Radio-
frequency connectors, can be found on the IEC website.
The committee has decided that the contents of this publication will remain unchanged until
the stability date indicated on the IEC web site under "http://webstore.iec.ch" in the data
related to the specific publication. At this date, the publication will be
• reconfirmed,
• withdrawn,
• replaced by a revised edition, or
• amended.
A bilingual version of this publication may be issued at a later date.

IMPORTANT – The 'colour inside' logo on the cover page of this publication indicates
that it contains colours which are considered to be useful for the correct
understanding of its contents. Users should therefore print this document using a
colour printer.
– 6 – 61169-43 © IEC:2013(E)
RADIO-FREQUENCY CONNECTORS –
Part 43: Sectional specification for RBMA series
blind mating RF coaxial connectors

1 Scope
This part of IEC 61169 which is a sectional specification (SS) provides information and rules
for the preparation of detail specifications (DS) for RBMA series RF coaxial connectors, with
characteristic impedance of 50 Ω, with threaded coupling and operating frequency limit up to
12,4 GHz, used in wireless, microwave, telecommunication, and other fields, connecting with
RF cables or micro-strips.
It also prescribes mating face dimensions for general connectors-grade 2, dimensional details
of standard test connectors-grade 0, gauging information and tests selected from
IEC 61169-1, applicable to all detail specifications relating to RBMA series connectors.
This specification indicates the recommended performance characteristics to be considered
when writing a detail specification and it covers test schedules and inspection requirements
for assessment levels M and H (see Tables 8 and 9).
2 Normative references
The following documents, in whole or in part, are normatively referenced in this document and
are indispensable for its application. For dated references, only the edition cited applies. For
undated references, the latest edition of the referenced document (including any
amendments) applies.
IEC 61169-1:1992, Radio-frequency connectors – Part 1: Generic specification – General
requirements and measuring methods
Amendment 1:1996
Amendment 2:1997
3 Mating face and gauge information
3.1 Dimensions – General connectors – Grade 2
3.1.1 Connector with pin-centre contact
All undimensioned pictorial configurations are for reference purpose only.

—————————
There exists a consolidated edition 1.2 (1998) that comprises IEC 61169-1:1992, its Amendment 1:1996 and its
Amendment 2:1997.
61169-43 © IEC:2013(E) – 7 –
k
l
g
Note 2
h
j
Note 1
i
IEC  573/13
Figure 1 – Connector with pin- centre contact
(for dimensions and notes, see Table 1)

Table 1 – Dimensions of connector with pin-centre contact
Ref. mm Notes
Min. Max.
a – 4,18 Note 4
b – – Note 3
c 5,55 5,60
d – – Note 4
e 0,90 0,94
f – 0,30
g 0,00 0,25
h 0,00 0,25
i 1,27 –
j – 2,54
k 5,45 5,55
l 42° 48° Angle
m 7,40 7,60
n 8,00 –
NOTE 1 Mechanical and electrical reference plane.
NOTE 2 Spring fingers, the structure is optional.
NOTE 3 Dimensions are chosen to meet mechanical performance requirements.
NOTE 4 These diameters are for PTFE insulation with a dielectric constant of
2,02. Characteristic impedance of transmission is determined by diameters "a" and
"d" to be 50 Ω within the tolerances as stated in the DS.
∅f
∅e
Note 4 ∅d
∅a
∅b Note 3
∅c
∅m
∅n
– 8 – 61169-43 © IEC:2013(E)
3.1.2 Connector with socket-centre contact

k
Note 2
l
g
h
j
Note 1
IEC  574/13
Figure 2 – Connector with socket-centre contact
(for dimensions and notes, see Table 2)

Table 2 – Dimensions of connector with socket-centre contact
Ref. mm Notes
Min. Max.
a  – 4,18 Note 3
b 4,85    4,95
c 5,31 5,36
d  – – Note 3
e      – – Note 4
g 0,00 0,25
h 0,00 0,25
j 2,00 –
k 5,60 –
l 8 ° 12° Angle
NOTE 1 Mechanical and electrical reference plane.
NOTE 2 Design and location of the seal feature is optional, in order to meet
environmental performance requirements when mating interface separation is not
more than 0,38 mm.
NOTE 3 These diameters are for PTFE insulation with a dielectric constant of 2,02.
Characteristic impedance of transmission is determined by diameters "a" and "d" to
be 50 Ω within the tolerances as stated in the DS.
NOTE 4 Design for slotting is optional, to meet electrical and mechanical
requirements, when mating with φ 0,90 mm to φ 0,94 mm pin.

∅c
Note 3
∅d
∅b
∅e
Note 4 ∅a
61169-43 © IEC:2013(E) – 9 –
3.2 Gauges
3.2.1 Gauge pin for socket-centre contact

50°
∅a
∅0,2 mm max.
R0,2 mm max.
Blend radius
IEC  575/13
Figure 3 – Gauge pin for socket-centre contact
(for dimensions and notes, see Table 3)

Table 3 – Dimensions of gauge pin for socket-centre contact
Ref. Gauge A Gauge B
Minimum material for
measurement of retention force
Maximum material for sizing
purposes Mass of gauge: 28 g +2 g
mm mm
Min. Max. Min. Max.
a 0,940 0,945 0,899 0,902
b 0,76 1,14 1,27 1,90
Material: steel, polished.
Surface roughness: Ra = 0,4 μm maximum on the cylindrical surface of length b.

3.2.1.1 Test procedure
The gauge A shall be inserted into the socket-centre contact three times with a minimum
depth of 0,76 mm. This is a sizing operation and should only be carried out when the socket-
centre contact is removed from the connector.
After this, the gauge B shall have a withdrawal force of 0,28 N minimum after being inserted
into socket-centre contact. The contact shall retain the mass of the gauge in a vertical
downward position. This test shall also be carried out on connector when the socket-centre
contact is not removed.
b
– 10 – 61169-43 © IEC:2013(E)
3.2.2 Gauge for outer contact of connector with pin-centre contact

∅a
∅b
∅c
10° ± 30′
IEC  576/13
Figure 4 – Gauge for outer contact of connector with pin-centre contact
(for dimensions and notes, see Table 4)

Table 4 – Gauge for outer contact of connector with pin-centre contact
Ref. Gauge A Gauge B
Maximum material for sizing Minimum material for
purposes measurement of retention force
Mass of gauge: 56 g +2 g
mm mm
Min. Max. Min. Max.
a 5,360 5,365 5,305 5,310
b 4,85 4,95 4,85 4,95
c 2,50 – 2,50 –
d 4,00 – 4,00 –
e 5,60 – 5,60 –
Material: steel, polished.
Surface roughness: Ra ≤ 0,4 μm on the cylindrical surface of length e.

3.2.2.1 Test procedure
The gauge A shall be inserted into the outer contact three times. This is a sizing operation.
After this, the gauge B shall have a withdrawal force of 0,56 N minimum after being inserted
into outer contact. The contact shall retain the mass of the gauge in a vertical downward
position.
d
e
61169-43 © IEC:2013(E) – 11 –
3.3 Dimensions – Standard test connectors – Grade 0
3.3.1 Connector with pin-centre contact

Note 1 k
A
g l
Note 2
h
∅0,013 mm B
Note 1 j
i
B
A
∅0,025 mm
IEC  577/13
Figure 5 – Connector with pin-centre contact (G0)
(for dimensions and notes, see Table 5)

∅f
∅e
Note 4 ∅d
∅a
Note 3
∅b
∅c
∅m
∅n
– 12 – 61169-43 © IEC:2013(E)
Table 5 – Dimensions of connector with pin-centre contact (G0)
Ref. mm Notes
Min. Max.
a 4,10 4,13
b – – Note 3
c 5,55 5,60
d 1,27 nominal
e 0,902 0,927
f – 0,30
g 0,00 0,15
h 0,00 0,15
i 1,27 1,37
j 2,03 2,29
k 5,45 5,55
l 42 ° 48 ° Angle
m 7,40 7,60
n 8,00 –
NOTE 1 Mechanical and electrical reference plane.
NOTE 2 Spring fingers, the structure is optional.
NOTE 3 Dimensions are chosen to meet mechanical performance requirements.
NOTE 4 The diameter is chosen upon the assumption that the PTFE dielectric has a
dielectric constant of 2,02 to give an impedance of 50 Ω ± 0,5 Ω.

3.3.2 Connector with socket-centre contact

0,015 mm A
k
Note 1
l
g
A
h
j
B
∅0,013 mm B
IEC  578/13
Figure 6 – Connector with socket-centre contact
(for dimensions and notes, see Table 6)

∅c
∅b
∅a
Note 2
∅d
∅e
61169-43 © IEC:2013(E) – 13 –
Table 6 – Dimensions of connector with socket-centre contact
Ref. mm Notes
Min. Max.
a 4,10 4,13
b 4,85 4,95
c 5,31 5,36
d 1,27 nominal
e – – Note 3
g 0,00 0,15
h 0,00 0,15
j 3,05 3,30
k 5,60 –
l 8° 12° Angle
NOTE 1 Mechanical and electrical reference plane.
NOTE 2 The diameters are chosen upon the assumption that the PTFE dielectric has
a dielectric constant of 2,02 to give an impedance of 50 Ω ± 0,5 Ω.
NOTE 3 Design for slotting optional, to meet electrical and mechanical requirements,
when mating with φ 0,902 mm to φ 0,927 mm pin.

3.4 General requirements for connector mounting in modules and on panels
3.4.1 Limits of permissible connector radial misalignment and axial misalignment
3.4.1.1 General
When designing the mounting arrangements for RBMA series connectors, it is essential that
the disposition of individual pairs of connectors and their engagement is controlled within the
following general limiting conditions.
3.4.1.2 Radial misalignment
The radial misalignment between engaging connectors refers to the concentricity error
between diameter c of a connector with pin-centre contact and diameter c of a connector with
socket-centre contact at the beginning and during the engagement (see 3.1).
A rigidly mounted connector with socket-centre contact and a rigidly mounted connector with
pin-centre contact (see Figure 7) shall accept a radial misalignment within aa (0,095 mm) at
the beginning and during the engagement.

– 14 – 61169-43 © IEC:2013(E)
IEC  579/13
Figure 7 – Rigidly mounted connector with socket-centre contact and rigidly
mounted connector with pin-
...


IEC 61169-43 ®
Edition 1.0 2013-03
INTERNATIONAL
STANDARD
NORME
INTERNATIONALE
colour
inside
Radio-frequency connectors –
Part 43: Sectional specification for RBMA series blind mating RF coaxial
connectors
Connecteurs pour fréquences radioélectriques –
Partie 43: Spécification intermédiaire relative aux connecteurs coaxiaux RF à
accouplement en aveugle, série RBMA

All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form
or by any means, electronic or mechanical, including photocopying and microfilm, without permission in writing from
either IEC or IEC's member National Committee in the country of the requester. If you have any questions about IEC
copyright or have an enquiry about obtaining additional rights to this publication, please contact the address below or
your local IEC member National Committee for further information.

Droits de reproduction réservés. Sauf indication contraire, aucune partie de cette publication ne peut être reproduite
ni utilisée sous quelque forme que ce soit et par aucun procédé, électronique ou mécanique, y compris la photocopie
et les microfilms, sans l'accord écrit de l'IEC ou du Comité national de l'IEC du pays du demandeur. Si vous avez des
questions sur le copyright de l'IEC ou si vous désirez obtenir des droits supplémentaires sur cette publication, utilisez
les coordonnées ci-après ou contactez le Comité national de l'IEC de votre pays de résidence.

IEC Central Office Tel.: +41 22 919 02 11
3, rue de Varembé Fax: +41 22 919 03 00
CH-1211 Geneva 20 info@iec.ch
Switzerland www.iec.ch
About the IEC
The International Electrotechnical Commission (IEC) is the leading global organization that prepares and publishes
International Standards for all electrical, electronic and related technologies.

About IEC publications
The technical content of IEC publications is kept under constant review by the IEC. Please make sure that you have the
latest edition, a corrigenda or an amendment might have been published.

IEC Catalogue - webstore.iec.ch/catalogue Electropedia - www.electropedia.org
The stand-alone application for consulting the entire The world's leading online dictionary of electronic and
bibliographical information on IEC International Standards, electrical terms containing more than 30 000 terms and
Technical Specifications, Technical Reports and other definitions in English and French, with equivalent terms in 14
documents. Available for PC, Mac OS, Android Tablets and additional languages. Also known as the International
iPad. Electrotechnical Vocabulary (IEV) online.

IEC publications search - www.iec.ch/searchpub IEC Glossary - std.iec.ch/glossary
The advanced search enables to find IEC publications by a More than 55 000 electrotechnical terminology entries in
variety of criteria (reference number, text, technical English and French extracted from the Terms and Definitions
committee,…). It also gives information on projects, replaced clause of IEC publications issued since 2002. Some entries
and withdrawn publications. have been collected from earlier publications of IEC TC 37,

77, 86 and CISPR.
IEC Just Published - webstore.iec.ch/justpublished
Stay up to date on all new IEC publications. Just Published IEC Customer Service Centre - webstore.iec.ch/csc
details all new publications released. Available online and If you wish to give us your feedback on this publication or
also once a month by email. need further assistance, please contact the Customer Service
Centre: csc@iec.ch.
A propos de l'IEC
La Commission Electrotechnique Internationale (IEC) est la première organisation mondiale qui élabore et publie des
Normes internationales pour tout ce qui a trait à l'électricité, à l'électronique et aux technologies apparentées.

A propos des publications IEC
Le contenu technique des publications IEC est constamment revu. Veuillez vous assurer que vous possédez l’édition la
plus récente, un corrigendum ou amendement peut avoir été publié.

Catalogue IEC - webstore.iec.ch/catalogue Electropedia - www.electropedia.org
Application autonome pour consulter tous les renseignements
Le premier dictionnaire en ligne de termes électroniques et
bibliographiques sur les Normes internationales,
électriques. Il contient plus de 30 000 termes et définitions en
Spécifications techniques, Rapports techniques et autres
anglais et en français, ainsi que les termes équivalents dans
documents de l'IEC. Disponible pour PC, Mac OS, tablettes
14 langues additionnelles. Egalement appelé Vocabulaire
Android et iPad.
Electrotechnique International (IEV) en ligne.

Recherche de publications IEC - www.iec.ch/searchpub
Glossaire IEC - std.iec.ch/glossary
Plus de 55 000 entrées terminologiques électrotechniques, en
La recherche avancée permet de trouver des publications IEC
en utilisant différents critères (numéro de référence, texte, anglais et en français, extraites des articles Termes et
comité d’études,…). Elle donne aussi des informations sur les Définitions des publications IEC parues depuis 2002. Plus
projets et les publications remplacées ou retirées. certaines entrées antérieures extraites des publications des

CE 37, 77, 86 et CISPR de l'IEC.
IEC Just Published - webstore.iec.ch/justpublished

Service Clients - webstore.iec.ch/csc
Restez informé sur les nouvelles publications IEC. Just
Published détaille les nouvelles publications parues. Si vous désirez nous donner des commentaires sur cette
Disponible en ligne et aussi une fois par mois par email. publication ou si vous avez des questions contactez-nous:
csc@iec.ch.
IEC 61169-43 ®
Edition 1.0 2013-03
INTERNATIONAL
STANDARD
NORME
INTERNATIONALE
colour
inside
Radio-frequency connectors –
Part 43: Sectional specification for RBMA series blind mating RF coaxial

connectors
Connecteurs pour fréquences radioélectriques –

Partie 43: Spécification intermédiaire relative aux connecteurs coaxiaux RF à

accouplement en aveugle, série RBMA

INTERNATIONAL
ELECTROTECHNICAL
COMMISSION
COMMISSION
ELECTROTECHNIQUE
PRICE CODE
INTERNATIONALE
CODE PRIX U
ICS 33.120.30 ISBN 978-2-8322-1316-2

– 2 – 61169-43 © IEC:2013
CONTENTS
FOREWORD . 4
1 Scope . 6
2 Normative references . 6
3 Mating face and gauge information . 6
3.1 Dimensions – General connectors – Grade 2 . 6
3.1.1 Connector with pin-centre contact . 6
3.1.2 Connector with socket-centre contact . 8
3.2 Gauges . 9
3.2.1 Gauge pin for socket-centre contact . 9
3.2.2 Gauge for outer contact of connector with pin-centre contact . 10
3.3 Dimensions – Standard test connectors – Grade 0 . 11
3.3.1 Connector with pin-centre contact . 11
3.3.2 Connector with socket-centre contact . 12
3.4 General requirements for connector mounting in modules and on panels . 13
3.4.1 Limits of permissible connector radial misalignment and axial
misalignment . 13
3.4.2 Specific connector mounting details . 16
4 Quality assessment procedure . 16
4.1 General . 16
4.2 Rating and characteristics (see Clause 6 of IEC 61169-1:1992) . 17
4.3 Test schedule and inspection requirements . 20
4.3.1 Acceptance tests . 20
4.3.2 Periodic tests. 21
4.4 Procedures . 22
4.4.1 Quality conformance inspection . 22
4.4.2 Qualification approval and its maintenance . 22
5 Instructions for preparation of detail specifications . 23
5.1 General . 23
5.2 Identification of the component . 23
5.3 Performance . 23
5.4 Marking, ordering information and related matters . 23
5.5 Selection of tests, test conditions and severities . 23
5.6 Blank detail specification pro-forma for series RBMA connectors . 24

Figure 1 – Connector with pin- centre contact . 7
Figure 2 – Connector with socket-centre contact . 8
Figure 3 – Gauge pin for socket-centre contact . 9
Figure 4 – Gauge for outer contact of connector with pin-centre contact . 10
Figure 5 – Connector with pin-centre contact (G0) . 11
Figure 6 – Connector with socket-centre contact . 12
Figure 7 – Rigidly mounted connector with socket-centre contact and rigidly mounted
connector with pin-centre contact radial misalignment limits . 14
Figure 8 – Rigidly mounted connector with socket-centre contact and float-mounted
connector with pin-centre contact radial misalignment limits . 14
Figure 9 – Floating connector self-aligned . 15
Figure 10 – Separation between the two reference planes . 16

61169-43 © IEC:2013 – 3 –
Figure 11 – Axial misalignment limits . 16

Table 1 – Dimensions of connector with pin-centre contact . 7
Table 2 – Dimensions of connector with socket-centre contact . 8
Table 3 – Dimensions of gauge pin for socket-centre contact . 9
Table 4 – Gauge for outer contact of connector with pin-centre contact . 10
Table 5 – Dimensions of connector with pin-centre contact (G0) . 12
Table 6 – Dimensions of connector with socket-centre contact . 13
Table 7 – Rating and characteristics . 17
Table 8 – Acceptance tests . 20
Table 9 – Periodic tests . 21

– 4 – 61169-43 © IEC:2013
INTERNATIONAL ELECTROTECHNICAL COMMISSION
____________
RADIO-FREQUENCY CONNECTORS –
Part 43: Sectional specification for RBMA series
blind mating RF coaxial connectors

FOREWORD
1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of IEC is to promote
international co-operation on all questions concerning standardization in the electrical and electronic fields. To
this end and in addition to other activities, IEC publishes International Standards, Technical Specifications,
Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC
Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested
in the subject dealt with may participate in this preparatory work. International, governmental and non-
governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely
with the International Organization for Standardization (ISO) in accordance with conditions determined by
agreement between the two organizations.
2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international
consensus of opinion on the relevant subjects since each technical committee has representation from all
interested IEC National Committees.
3) IEC Publications have the form of recommendations for international use and are accepted by IEC National
Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC
Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any
misinterpretation by any end user.
4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications
transparently to the maximum extent possible in their national and regional publications. Any divergence
between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in
the latter.
5) IEC itself does not provide any attestation of conformity. Independent certification bodies provide conformity
assessment services and, in some areas, access to IEC marks of conformity. IEC is not responsible for any
services carried out by independent certification bodies.
6) All users should ensure that they have the latest edition of this publication.
7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and
members of its technical committees and IEC National Committees for any personal injury, property damage or
other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and
expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC
Publications.
8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is
indispensable for the correct application of this publication.
9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of
patent rights. IEC shall not be held responsible for identifying any or all such patent rights.
International Standard IEC 61169-43 has been prepared by subcommittee 46F: R.F. and
microwave passive components, of IEC technical committee 46: Cables, wires, waveguides,
R.F. connectors, R.F. and microwave passive components and accessories.
This bilingual version (2014-01) corresponds to the monolingual English version, published in
2013-03.
The text of this standard is based on the following documents:
FDIS Report on voting
46F/221/FDIS 46F/227/RVD
Full information on the voting for the approval of this standard can be found in the report on
voting indicated in the above table.

61169-43 © IEC:2013 – 5 –
The French version of this standard has not been voted upon.
This publication has been drafted in accordance with the ISO/IEC Directives, Part 2.
A list of all the parts in the IEC 61169 series, published under the general title Radio-
frequency connectors, can be found on the IEC website.
The committee has decided that the contents of this publication will remain unchanged until
the stability date indicated on the IEC web site under "http://webstore.iec.ch" in the data
related to the specific publication. At this date, the publication will be
• reconfirmed,
• withdrawn,
• replaced by a revised edition, or
• amended.
IMPORTANT – The 'colour inside' logo on the cover page of this publication indicates
that it contains colours which are considered to be useful for the correct
understanding of its contents. Users should therefore print this document using a
colour printer.
– 6 – 61169-43 © IEC:2013
RADIO-FREQUENCY CONNECTORS –
Part 43: Sectional specification for RBMA series
blind mating RF coaxial connectors

1 Scope
This part of IEC 61169 which is a sectional specification (SS) provides information and rules
for the preparation of detail specifications (DS) for RBMA series RF coaxial connectors, with
characteristic impedance of 50 Ω, with threaded coupling and operating frequency limit up to
12,4 GHz, used in wireless, microwave, telecommunication, and other fields, connecting with
RF cables or micro-strips.
It also prescribes mating face dimensions for general connectors-grade 2, dimensional details
of standard test connectors-grade 0, gauging information and tests selected from
IEC 61169-1, applicable to all detail specifications relating to RBMA series connectors.
This specification indicates the recommended performance characteristics to be considered
when writing a detail specification and it covers test schedules and inspection requirements
for assessment levels M and H (see Tables 8 and 9).
2 Normative references
The following documents, in whole or in part, are normatively referenced in this document and
are indispensable for its application. For dated references, only the edition cited applies. For
undated references, the latest edition of the referenced document (including any
amendments) applies.
IEC 61169-1:1992, Radio-frequency connectors – Part 1: Generic specification – General
requirements and measuring methods
Amendment 1:1996
Amendment 2:1997
3 Mating face and gauge information
3.1 Dimensions – General connectors – Grade 2
3.1.1 Connector with pin-centre contact
All undimensioned pictorial configurations are for reference purpose only.

—————————
There exists a consolidated edition 1.2 (1998) that comprises IEC 61169-1:1992, its Amendment 1:1996 and its
Amendment 2:1997.
61169-43 © IEC:2013 – 7 –
k
l
g
Note 2
h
j
Note 1
i
IEC  573/13
Figure 1 – Connector with pin- centre contact
(for dimensions and notes, see Table 1)

Table 1 – Dimensions of connector with pin-centre contact
Ref. mm Notes
Min. Max.
a – 4,18 Note 4
b – – Note 3
c 5,55 5,60
d – – Note 4
e 0,90 0,94
f – 0,30
g 0,00 0,25
h 0,00 0,25
i 1,27 –
j – 2,54
k 5,45 5,55
l 42° 48° Angle
m 7,40 7,60
n 8,00 –
NOTE 1 Mechanical and electrical reference plane.
NOTE 2 Spring fingers, the structure is optional.
NOTE 3 Dimensions are chosen to meet mechanical performance requirements.
NOTE 4 These diameters are for PTFE insulation with a dielectric constant of
2,02. Characteristic impedance of transmission is determined by diameters "a" and
"d" to be 50 Ω within the tolerances as stated in the DS.
∅f
∅e
Note 4 ∅d
∅a
∅b Note 3
∅c
∅m
∅n
– 8 – 61169-43 © IEC:2013
3.1.2 Connector with socket-centre contact

k
Note 2
l
g
h
j
Note 1
IEC  574/13
Figure 2 – Connector with socket-centre contact
(for dimensions and notes, see Table 2)

Table 2 – Dimensions of connector with socket-centre contact
Ref. mm Notes
Min. Max.
a  – 4,18 Note 3
b 4,85    4,95
c 5,31 5,36
d  – – Note 3
e      – – Note 4
g 0,00 0,25
h 0,00 0,25
j 2,00 –
k 5,60 –
l 8 ° 12° Angle
NOTE 1 Mechanical and electrical reference plane.
NOTE 2 Design and location of the seal feature is optional, in order to meet
environmental performance requirements when mating interface separation is not
more than 0,38 mm.
NOTE 3 These diameters are for PTFE insulation with a dielectric constant of 2,02.
Characteristic impedance of transmission is determined by diameters "a" and "d" to
be 50 Ω within the tolerances as stated in the DS.
NOTE 4 Design for slotting is optional, to meet electrical and mechanical
requirements, when mating with φ 0,90 mm to φ 0,94 mm pin.

∅c
Note 3
∅d
∅b
∅e
Note 4 ∅a
61169-43 © IEC:2013 – 9 –
3.2 Gauges
3.2.1 Gauge pin for socket-centre contact

50°
∅a
∅0,2 mm max.
R0,2 mm max.
Blend radius
IEC  575/13
Figure 3 – Gauge pin for socket-centre contact
(for dimensions and notes, see Table 3)

Table 3 – Dimensions of gauge pin for socket-centre contact
Ref. Gauge A Gauge B
Minimum material for
measurement of retention force
Maximum material for sizing
purposes Mass of gauge: 28 g +2 g
mm mm
Min. Max. Min. Max.
a 0,940 0,945 0,899 0,902
b 0,76 1,14 1,27 1,90
Material: steel, polished.
Surface roughness: Ra = 0,4 µm maximum on the cylindrical surface of length b.

3.2.1.1 Test procedure
The gauge A shall be inserted into the socket-centre contact three times with a minimum
depth of 0,76 mm. This is a sizing operation and should only be carried out when the socket-
centre contact is removed from the connector.
After this, the gauge B shall have a withdrawal force of 0,28 N minimum after being inserted
into socket-centre contact. The contact shall retain the mass of the gauge in a vertical
downward position. This test shall also be carried out on connector when the socket-centre
contact is not removed.
b
– 10 – 61169-43 © IEC:2013
3.2.2 Gauge for outer contact of connector with pin-centre contact

∅a
∅b
∅c
10° ± 30′
IEC  576/13
Figure 4 – Gauge for outer contact of connector with pin-centre contact
(for dimensions and notes, see Table 4)

Table 4 – Gauge for outer contact of connector with pin-centre contact
Ref. Gauge A Gauge B
Maximum material for sizing Minimum material for
purposes measurement of retention force
Mass of gauge: 56 g +2 g
mm mm
Min. Max. Min. Max.
a 5,360 5,365 5,305 5,310
b 4,85 4,95 4,85 4,95
c 2,50 – 2,50 –
d 4,00 – 4,00 –
e 5,60 – 5,60 –
Material: steel, polished.
Surface roughness: Ra ≤ 0,4 µm on the cylindrical surface of length e.

3.2.2.1 Test procedure
The gauge A shall be inserted into the outer contact three times. This is a sizing operation.
After this, the gauge B shall have a withdrawal force of 0,56 N minimum after being inserted
into outer contact. The contact shall retain the mass of the gauge in a vertical downward
position.
d
e
61169-43 © IEC:2013 – 11 –
3.3 Dimensions – Standard test connectors – Grade 0
3.3.1 Connector with pin-centre contact

Note 1 k
A
g l
Note 2
h
∅0,013 mm B
Note 1 j
i
B
A
∅0,025 mm
IEC  577/13
Figure 5 – Connector with pin-centre contact (G0)
(for dimensions and notes, see Table 5)

∅f
∅e
Note 4 ∅d
∅a
Note 3
∅b
∅c
∅m
∅n
– 12 – 61169-43 © IEC:2013
Table 5 – Dimensions of connector with pin-centre contact (G0)
Ref. mm Notes
Min. Max.
a 4,10 4,13
b – – Note 3
c 5,55 5,60
d 1,27 nominal
e 0,902 0,927
f – 0,30
g 0,00 0,15
h 0,00 0,15
i 1,27 1,37
j 2,03 2,29
k 5,45 5,55
l 42 ° 48 ° Angle
m 7,40 7,60
n 8,00 –
NOTE 1 Mechanical and electrical reference plane.
NOTE 2 Spring fingers, the structure is optional.
NOTE 3 Dimensions are chosen to meet mechanical performance requirements.
NOTE 4 The diameter is chosen upon the assumption that the PTFE dielectric has a
dielectric constant of 2,02 to give an impedance of 50 Ω ± 0,5 Ω.

3.3.2 Connector with socket-centre contact

0,015 mm A
k
Note 1
l
g
A
h
j
B
B
∅0,013 mm
IEC  578/13
Figure 6 – Connector with socket-centre contact
(for dimensions and notes, see Table 6)

∅c
∅b
∅a
Note 2
∅d
∅e
61169-43 © IEC:2013 – 13 –
Table 6 – Dimensions of connector with socket-centre contact
Ref. mm Notes
Min. Max.
a 4,10 4,13
b 4,85 4,95
c 5,31 5,36
d 1,27 nominal
e – – Note 3
g 0,00 0,15
h 0,00 0,15
j 3,05 3,30
k 5,60 –
l 8° 12° Angle
NOTE 1 Mechanical and electrical reference plane.
NOTE 2 The diameters are chosen upon the assumption that the PTFE dielectric has
a dielectric constant of 2,02 to give an impedance of 50 Ω ± 0,5 Ω.
NOTE 3 Design for slotting optional, to meet electrical and mechanical requirements,
when mating with φ 0,902 mm to φ 0,927 mm pin.

3.4 General requirements for connector mounting in modules and on panels
3.4.1 Limits of permissible connector radial misalignment and axial misalignment
3.4.1.1 General
When designing the mounting arrangements for RBMA series connectors, it is essential that
the disposition of individual pairs of connectors and their engagement is controlled within the
following general limiting conditions.
3.4.1.2 Radial misalignment
The radial misalignment between engaging connectors refers to the concentricity error
between diameter c of a connector with pin-centre contact and diameter c of a connector with
socket-centre contact at the beginning and during the engagement (see 3.1).
A rigidly mounted connector with socket-centre contact and a rigidly mounted connector with
pin-centre contact (see Figure 7) shall accept a radial misalignment within aa (0,095 mm) at
the beginning and during the engagement.

– 14 – 61169-43 © IEC:2013
IEC  579/13
Figure 7 – Rigidly mounted connector with socket-centre contact and rigidly
mounted connector with pin-centre contact radial misalignment limits
A rigidly mounted connector with socket-centre contact and float-mounted connector with pin-
centre contact (see Figure 8) shall accept a radial misalignment within bb (0,6 mm) at the
beginning of the engagement.
IEC  580/13
Figure 8 – Rigidly mounted connector with socket-centre contact and float-mounted
connector with pin-centre contact radial misalignment limits
During the engagement, the floating connector shall be able to align itself with the rigidly
mounted connector within cc (0,095 mm) (see Figure 9).

aa
bb
61169-43 © IEC:2013 – 15 –
IEC  581/13
Figure 9 – Floating connector self-aligned
3.4.1.3 Axial misalignment
Rigidly mounted connector with socket-centre contact and rigidly mounted connector with pin-
centre contact .To maintain the electrical and environmental performance, separation between
the two reference planes should be within dd (0,38 mm) (see Figure 10). Further separation
up to dd (0,76 mm) will degrade electrical performance and negate the environmental
performance.
cc
– 16 – 61169-43 © IEC:2013
Mechanical and electrical
reference plane
dd
IEC  582/13
Figure 10 – Separation between the two reference planes
Rigidly mounted connector with socket-centre contact and float-mounted connector with pin-
centre contact (see Figure 11). The float mounting allows a total of ee (2,20 mm) axial travel.
The mounting arrangements should, however, ensure a minimum length of travel of ee
(0,20 mm) to ensure that full length of engagement is maintained under operational
conditions.
Axial working range
Axial float
ee
Cable
Mechanical and electrical
reference plane
IEC  583/13
Figure 11 – Axial misalignment limits
3.4.2 Specific connector mounting details
In addition to details of the panel cut-out and maximum panel thickness, the detail
specification shall specify the minimum centre-line separation between adjacent connectors,
in both the X and Y coordinates (if different).
4 Quality assessment procedure
4.1 General
Subclauses 4.2 to 4.4 provide recommended rating, performance and test conditions to be
considered when writing a detail specification. They also provide an appropriate schedule of
tests with minimum levels of conformance inspection sampling, together with the pro-forma
blank detail specification (BDS) and instructions for the preparation of a detail specification.

61169-43 © IEC:2013 – 17 –
4.2 Rating and characteristics (see Clause 6 of IEC 61169-1:1992)
The values indicated below (see Table 7) are recommended for RBMA series RF coaxial
connectors and are given for the writer of the detail specification. They are applicable for the
condition when the connectors are fully mated.
Certain tests are listed without any recommended values being given. These tests will usually
not be required. When these tests are required, appropriate values shall be entered in the
detail specification at the discretion of the specification writer.
Table 7 – Rating and characteristics
Rating and characteristics Value Remarks, deviations
IEC 61169- from standard test
1:1992 method
Subclause
Electrical
Nominal impedance
50 Ω
Frequency range   Or upper frequency
limit of cable
Grade 2 connectors Up to 12,4 GHz
a
Reflection factor 9.2.1
Grade 2 connectors
– For flexible cable
≤ 0,090+0,01f
– straight styles
See DS
– right-angle styles
– For semi-rigid and semi-flexible cable
≤ 0,050+0,01f
– straight styles
See DS
– right-angle styles
See DS
– Component mounting styles
See DS
– Solder bucket and PCB mounting
styles
b
Centre contact resistance 9.2.3
– initial ≤ 3,0 mΩ
– after conditioning
≤ 6,0 mΩ
b
Outer conductor continuity 9.2.3
– initial ≤ 2,5 mΩ
– after conditioning
≤ 3,0 mΩ
b
Insulation resistance 9.2.5
– initial
≥ 5 000 MΩ
– after conditioning
≥ 200 MΩ
– 18 – 61169-43 © IEC:2013
Rating and characteristics Value Remarks, deviations
IEC 61169- from standard test
1:1992 method
Subclause
c,d
Proof voltage at sea level 9.2.6
– non-cable styles 1 000 V
– 96IEC50-3 750 V
– 96IEC50-2 500 V
– 96IEC50-1 350 V
– semi-rigid and semi-flexible 3,58 mm 1 000 V
(0,141 in) diameter
– semi-rigid and semi-flexible 2,16 mm
750 V
(0,086 in) diameter
– semi-rigid and semi-flexible 1,19 mm
(0,047 in) diameter
500 V
c,d
Proof voltage at 4,4 kPa 9.2.6
– non-cable styles  200 V 4,4 kPa
approximately
– 96IEC50-3 150 V
equivalent to 20 km
– 96IEC50-2 100 V
– 96IEC50-1 75 V
– semi-rigid and semi-flexible 200 V
3,58 mm (0,141 in) diameter
– semi-rigid and semi-flexible
150 V
2,16 mm (0,086 in) diameter
– semi-rigid and semi-flexible
1,19 mm (0,047 in) diameter
100 V
Environmental test voltage at sea 9.2.6
c,d
level
– non-cable styles 330 V
– 96IEC50-3 200 V
– 96IEC50-2 175 V
– 96IEC50-1 100 V
– semi-rigid and semi-flexible 330 V
3,58 mm (0,141 in) diameter
– semi-rigid and semi-flexible 2
200 V
16 mm (0,086 in) diameter
– semi-rigid and semi-flexible 1
19 mm (0,047 in) diameter
175 V
Environmental test voltage at 9.2.6
c,d
4,4 kPa
4,4 kPa
100 V
– non-cable styles approximately

equivalent to 20 km
75 V
– 96IEC50-3
65 V
– 96IEC50-2
45 V
– 96IEC50-1
100 V
– semi-rigid and semi-flexible
3,58 mm (0,141 in) diameter
– semi-rigid and semi-flexible
65 V
2,16 mm (0,086 in) diameter
– semi-rigid and semi-flexible
45 V
1,19 mm (0,047 in) diameter
61169-43 © IEC:2013 – 19 –
Rating and characteristics Value Remarks, deviations
IEC 61169- from standard test
1:1992 method
Subclause
Screening effectiveness (straight
g
cables only) 9.2.8 ≥ 60 dB, at 1 GHz
Discharge test (corona effect) 9.2.9 See DS Extinction voltage
Mechanical
Gauge retention force (resilient 9.3.4

contacts)
≥ 0,28 N
– centre contacts
≥ 0,56 N
– outer contacts
Centre contact captivation                 9.  3.  5
– axial force
≥ 22 N Interface dimensions
shall remain as
– torque
See DS
specified
Engagement and separation force 9.3.6
≤ 13,3 N
– Engagement
0,56 N to 6,7 N
– Separation
Mechanical tests on cable fixing
– cable rotation (nutation) 9.3.7.2 See DS
– cable pulling 9.3.8 See DS
– cable bending 9.3.9 See DS
– cable torsion             9.3.10 See DS
f
Tensile strength of coupling mechanism 9.3.11 na
f
Bending moment 9.3.12 na
Vibration 9.3.3 100 m/s  10 g
n
10 Hz to 2 000 Hz
Shock
9.3.14 500 m/s 50 gn
1/2 sine wave
11 ms
Environmental
Climatic category 9.4.2 55/125/21
f
Sealing non-hermetic 9.4.5.1 na
f
Hermetic 9.4.5.2 na
Salt mist 9.4.6 48 h spray
Endurance
Mechanical endurance 9.5 500 operations
e
High temperature endurance
9.6 250 h at 125 °C
a
These values apply to basic connector. In practice, these may be influenced by the cable used and reference
should always be made to the actual values given in the detail specification.
b
Values for a single pair of connectors.
c
Voltages are r.m.s values of AC at 40 Hz to 65 Hz, unless otherwise specified.
d
Some cables usable with these connectors have ratings lower than the values given here.
e
For certain connectors, the upper temperature limit is restricted by the cable characteristics. Reference
should be made to the relevant cable specification. When semi-rigid and semi-flexible cables are used, the
upper temperature is limited to 115 °C maximum.
f
na − not applicable.
g
When interfaces are fully mated.

– 20 – 61169-43 © IEC:2013
4.3 Test schedule and inspection requirements
4.3.1 Acceptance tests
Table 8 – Acceptance tests
Assessment level M (higher) Assessment level H (lower)
IEC 61169-
Test IL AQL Period Test IL AQL Period
1:1992
required required
% %
Subclause
Group A1
Visual examination 9.1.2 a II 1,0
a S3 1,5
Group B2
Outline dimensions 9.1.3.1 a S4 0,40 a S3 0,40

Mechanical 9.1.3.3 a II 1,0 a S3 1,5
compatibility
Lot Lot
Engagement and 9.3.6 a S4 0,40 a S3 1,5
separation
Gauge retention 9.3.4 ia II 1,0 ia S3 1,5
by by
(resilient contacts)
Sealing 9.4.5.1
- non-hermetic ia II 0,65 ia S3 1,0
lot lot
- hermetic 9.4.5.2 ia II 0,015 ia S3 0,025

Voltage proof 9.2.6 a II 0,40 a II 4,0

Solderability piece- 9.3.2.1.1 ia S4 0,40 ia S3 4,0

parts(d)
Insulation 9.2.5 a S4 0,40 a S3 4,0

resistance
ABBREVIATIONS:
a − applicable
na − not applicable
ia − test required (if technically applicable)
IL − inspection level
AQL − acceptable quality level

(d) – destructive test − specimens shall not be returned to stock

61169-43 © IEC:2013 – 21 –
4.3.2 Periodic tests
There are no group C tests for levels H and M.
Table 9 – Periodic tests
IEC 61169-1:1992 Assessment level M (higher) Assessment level H (lower)
Subclause
Test Number of Permitted Period Test Number of Permitted Period
required specimens failures required specimens failures
per per
group group
Group D1 (d)  6 0 3 3 0 3
years years
Solderability 9.3.2.1.1 ia ia

– connector
assemblies
Resistance to 9.3.2.1.2 ia ia
soldering
heat
Mechanical
tests on cable
ia
fixing
– cable
ia
9.3.7.2
rotation
(nutation)
– cable
ia ia
9.3.8
pulling
– cable
ia
9.3.9
bending
– cable
ia
9.3.10
torsion
Bending 9.3.12 ia ia
moment
Strength of 9.3.11 ia ia
coupling
mechanism
Group D2 (d)
6 0 3 3 0 3
years years
Contact 9.2.3 a a
resistance,
outer
conductor
and screen
continuity,
centre
conductor
continuity
c
Bump 9.3.13 a
Vibration 9.3.3 a
Shock 9.3.14 a
Salt mist 9.4.6 a
a a
Group D3  0 3 0 3
years years
Dimensions 9.1.3 a a
piece part
and materials
– 22 – 61169-43 © IEC:2013
IEC 61169-1:1992 Assessment level M (higher) Assessment level H (lower)
Subclause Test Number of Permitted Period Test Number of Permitted Period
required specimens failures required specimens failures
per per
group group
Group D4 (d)
6 0 3 3 0 3
years years
Mechanical 9.5 a a
endurance
High 9.6 a
temperature
endurance
Group D5 (d)  6 0 3 3 0 3
years years
Reflection 9.2.1 ia ia
factor
Screening 9.2.8 ia
effectiveness
c
Water 9.2.7 ia
immersion
Group D6  6 0 3 3 0 3
(d) years years
9.3.5 ia
Contact
captivation
Discharge 9.2.9 a
test (corona)
Rapid change 9.4.4 a a
of
temperature
Climatic 9.4.2 a a
sequence
Group D7 (d)
c b b
Resistance to 9.7 a 1 0 3 1 0 3
solvents and years years
contamination
fluids
ABBREVIATIONS:
a − applicable
ia − test required (if technically applicable)
(d) − destructive test − specimens shall not be returned to stock
a
One set of piece parts each style and variant, unless using common piece parts.
b
Group D7 – number of pairs for each solvent.
c
See detail specification.
4.4 Procedures
4.4.1 Quality conformance inspection
This shall consist of test groups A1 and B1 on a lot-by-lot basis.
4.4.2 Qualification approval and its maintenance
This still consists of three consecutive lots passing test groups A1 and B1 followed by
selection of specimens from the lots as appropriate. These specimens shall successfully pass
the specified periodic D tests.

61169-43 © IEC:2013 – 23 –
5 Instructions for preparation of detail specifications
5.1 General
Detail specifications (DS) shall use the appropriate blank detail specification (BDS). The
following pages comprise the BDS dedicated for use with series RBMA connectors. As such, it
will already have entered on it information relating to:
a) the basic specification number applicable to all the detail specifications covering
connector styles of the series covered by the sectional specification;
b) the connector series designation.
The specification writer should enter the details relating to the connector style to be covered
as indicated. The numbers in brackets in the BDS correspond to the following indications
which shall be given.
5.2 Identification of the component
1) Enter the following details:
– style: the style designation of the connector including type of fixing and sealing if
applicable;
– attachment: by deletion of the inapplicable options of cable /wire given for centre and
outer conductors.
– special features and markings: as applicable.
– series designation: in bold characters/digits approximately 15 mm high.
– Enter details of assessment level and the climatic category.
2) A reproduction of the outline drawing and details of the panel piercing (if applicable).It
shall provide the maximum envelope dimensions, also the position of the reference plane
and, in the case of a fixed connector, the position of the mounting plane both relative to
the front face of the connector.
3) Any maximum panel thickness limitations for fixed connectors shall be stated.
4) Particulars of all variants covered by the DS. As appropriate, the information shall include:
– cable types (or sizes) applicable to each variant;
– alternative plated or protective finishes;
– details of alternative mounting flanges having either tapped or plain mounting holes.
– details of alternative solder spills or solder buckets including, when applicable, those
for use with microwave integrated circuit (MIC) components.
5.3 Performance
5) Performance data listing the most important characteristics of the connector in accordance
with the requirements of the relevant sectional specification. Deviations from the minimum
requirements shall be clearly indicated. Not-applicable parameters shall be marked “na”.
5.4 Marking, ordering information and related matters
6) Insert marking and ordering information as appropriate, together with details of related
documents and any invoked structural similarity.
5.5 Selection of tests, test conditions and severities
7) “na” shall be used to indicate non-applicable tests. All tests marked “a” by the detail
specification writer shall be mandatory.

– 24 – 61169-43 © IEC:2013
When using the normal procedure with a dedicated BDS, the letter “a” – for applicable – shall
be entered in the “test required” column against each of the tests indicated as being
mandatory in the test schedule of the relevant sectional specification. Any additional test
required at the discretion of the specification writer shall also be indicated by an “a”.
The specification writer shall also indicate, when necessary, details of deviations from the
standard test methods and conditions including any relevant deviations given in the test
schedule of the sectional specification.
5.6 Blank detail specification pro-forma for series RBMA connectors
The following pages contain the complete BDS pro-forma.
(1) (2)  Page 1 of ….
ELECTRONIC COMPONENT OF ASSESSED ISSUE
QUALITY IN ACCORDANCE WITH
GENERIC SPECIFICATION IEC 61169-1 (3) .
NATIONAL REFERENCE
(4) .
(5) Detail specification for type RBMA
Radio frequency coaxial connector of assessed quality
Style:. Special features and markings
Method of cable/wire + attachment centre conductor – solder/crimp+
outer conductor – solder/clamp/crimp +
+ delete as appropriate
(6) Assessment level. Characteristic impedance Climatic category./././
50 Ω
(7) Outline and maximum dimensions Panel piercing and mounting details
(8) Variants
Variant No. Description of IEC 61196
variant
01. . . . .
............. ............. ............. ............. ............. .............
............. ............. ............. ............. ............. .............
............. ............. ............. ............. ............. .............
............. ............. ............. ............. ............. .............
............. ............. ............. ............. ............. .............
............. ............. ............. ............. ............. .............
.......
...