IEC 63387-1:2026
(Main)Hybrid CPV/PV modules: General characteristics and measurement procedures - Part 1: Performance measurements and power rating - Irradiance and temperature
- Abstract
IEC 63387-1:2026 specifies the methods for evaluating CPV/PV hybrid module performance in terms of power rating. Standard conditions for assessing the power produced by the module and the procedures to measure the power as a function of AOI, irradiance, and temperature are described. A methodology for determining a set of characterization parameter values for the hybrid CPV/PV module (FoV) is also included. In order to compare the performance of different hybrid CPV/PV modules whose output is discontinuous and time-dependent, the concept of effective nominal power is introduced.
This document is applicable to CPV/PV hybrid modules which include both solar cells designed to collect concentrated light (CPV cells array) and solar cells designed to collect diffuse or global light (PV cells array), the latter with bifacial or monofacial illumination. This document applies to hybrid CPV/PV modules with a geometrical concentration ratio > 3x for the CPV cells. For lower geometrical concentration ratio (≤ 3x), the IEC 60904-1 [11] and IEC 61853 series [9] apply.
- Status
- Published
- Publication Date
- 19-Aug-2026
- Technical Committee
- TC 82 - Solar photovoltaic energy systems
- Drafting Committee
- WG 2 - Modules
- Current Stage
- PPUB - Publication issued - 60 Publication
- Start Date
- 20-Aug-2026
- Due Date
- 28-Aug-2026
- Completion Date
- 28-Aug-2026
Buy Documents
iec63387-1{ed1.0}en - Hybrid CPV/PV modules: General characteristics and measurement procedures - Part 1: Performance measurements and power rating - Irradiance and temperature
iec63387-1{ed1.0}fr - Modules CPV/PV hybrides: caractéristiques générales et procédures de mesure - Partie 1: Mesurages de performances et caractéristiques assignées de puissance - Éclairement et température
IEC 63387-1:2026 is an IEC International Standard for hybrid CPV/PV modules. It specifies how to evaluate power rating and performance for modules that combine concentrated-light CPV cells with diffuse- or global-light PV cells, including measurements versus angle of incidence (AOI), irradiance, and temperature. The standard is written for module manufacturers, test laboratories, certification teams, and others who need comparable power ratings for fixed, single-axis, and integrated two-axis tracking designs.
What does IEC 63387-1:2026 specify?
IEC 63387-1:2026 specifies methods for power-rating evaluation of CPV/PV hybrid modules and introduces effective nominal power for comparing modules whose output is discontinuous and time-dependent. It also sets out the document structure: clauses 1 to 10 cover scope, references, terms, sampling, marking, manufacturer data, test methods, reporting, angular power sensitivity, and power-rating conditions; Annex A and Annex B provide informative guidance.
| Annex | What it covers |
|---|---|
| Annex A | General characteristics of CPV/PV hybrid modules, operating conditions, and module architectures |
| Annex B | Transient test sequence for a CPV/PV hybrid module with internal tracking |
The scope is limited to hybrid CPV/PV modules that include both CPV cells for concentrated light and PV cells for diffuse or global light, with the PV cells either monofacial or bifacial. It applies when the geometrical concentration ratio for the CPV cells is greater than 3x. For modules at 3x or below, the IEC 60904-1 and IEC 61853 series apply.
What are the key requirements of IEC 63387-1:2026?
IEC 63387-1:2026 sets the sampling, marking, measurement, conversion, and reporting steps needed to rate hybrid CPV/PV modules. The practical point is that the standard separates the CPV and PV contributions where needed, then combines them through AOI-dependent coefficients and an effective nominal power calculation.
- Clause 4 - Sampling: For performance qualification, three specimens are selected at random from one or more production lots in line with ISO 2859-1. Prototype devices are treated differently, and that must be recorded in the report. In practice, this tells the lab how many modules to test and whether production sampling rules apply.
- Clause 5 - Marking of the DUT: Each section of the device under test (DUT) must carry durable identification, including manufacturer identity, model, serial number, output polarity, maximum system voltage, and maximum output power with tolerance at the stated condition. This supports traceability and makes it easier to match test data to the physical module.
- Clause 6 - Manufacturer information: The manufacturer must provide the laboratory with the values needed for the measurement setup, including expected power, optical efficiency, open-circuit voltage and short-circuit current at the relevant standard and operating conditions, FoV or admission angle, installation instructions, surface ratio, and tracker angles. In practice, the test lab cannot configure the setup correctly without these inputs.
- Clause 7 - Test methods: Measurements are taken as functions of AOI and temperature, while following the manufacturer’s handling, cleaning, and connection instructions. If the manufacturer’s tracker is not used, the alignment details must be documented. This matters because tracker alignment affects the measured power.
- Clause 8 - Report: The test report must identify the laboratory, sample, method, measurement conditions, results, uncertainties, tracker and sensor details, and whether a back diode was used for CPV measurements. This is the record that buyers, auditors, and certification teams will use to judge the result.
- Clause 9 - Angular power sensitivity: The standard uses angular power sensitivity rather than only short-circuit current sensitivity, because mismatch effects can matter. It defines collection coefficients for PV internal cells, PV external cells, CPV cells, and rear illumination, then converts the values to 25 °C. In practice, this is how the AOI response is turned into usable rating data.
- Clause 10 - Power rating conditions: The standard distinguishes hybrid standard test and operating conditions, with different treatment for modules on fixed structures, single-axis trackers, and two-axis trackers. For fixed or single-axis installations, it introduces effective nominal power and gives measurement routes for low FoV and high FoV modules; for two-axis trackers, it rates the CPV group and the flat-plate PV group separately. This is the core of the power-rating procedure.
What terms does IEC 63387-1:2026 define?
- module CPV/PV hybride - A module that combines CPV cells for concentrated light and PV cells for global or diffuse light, with monofacial or bifacial illumination.
- champ de vision (FoV) - The angular range in which the normalized angular power of the CPV cells remains within 50% of its maximum; it is used to decide how the module is measured and rated.
- réponse angulaire normalisée d’un module CPV/PV hybride - The CPV angular power of the module normalized to its maximum value, used to compare performance versus AOI.
- surface opérationnelle - The area of the DUT intended for PV conversion, including the lens surface and any other PV-covered surfaces.
- surface d’entrée - The area between the inner edges of the DUT frame; it is used as a reference surface in the geometry description.
- surface totale - The entry surface plus the module frame surface; the standard uses it to define surface ratios.
- puissance nominale effective - The nominal power of a reference PV module with continuous AOI response that would produce the same annual energy as the hybrid module under clear-sky reference conditions.
Who uses IEC 63387-1:2026?
IEC 63387-1:2026 is used by CPV/PV hybrid module manufacturers, photovoltaic test laboratories, certification bodies, and quality teams that need a common basis for power rating. It is also useful to engineers and buyers comparing modules with different tracking architectures, FoV ranges, and output behaviors. In practice, the document supports module characterization, type testing, reporting, and technical review of performance claims.
Which standards are used with IEC 63387-1:2026?
| Standard | What it contributes |
|---|---|
| IEC TS 60904-1-2 | Measurement of current-voltage characteristics of bifacial PV devices |
| IEC TS 61836 | Solar PV terms, definitions, and symbols |
| IEC 62108 | Design qualification and approval for CPV modules and assemblies |
| IEC 62670-1 | CPV standard test and operating conditions |
| IEC 62670-3 | CPV performance measurement and power report methods |
| ISO 2859-1 | Lot sampling for attribute inspection |
| IEC 60904-1 series | Used when the geometrical concentration ratio is 3x or below |
| IEC 61853 series | Used for lower concentration ratio cases and PV performance rating context |
| IEC 60904-3 | Terrestrial PV reference-spectral measurement principles |
| IEC 60904-5 | Equivalent cell temperature determination for PV devices |
| IEC 60891 | IV-curve translation procedure used for current-voltage conversion |
| IEC 61853-2:2016 | AOI and temperature response model used in the power-rating calculations |
What does the IEC 63387-1:2026 document contain?
IEC 63387-1:2026 contains the full measurement and rating workflow for hybrid CPV/PV modules. Clauses 4 to 8 cover sampling, DUT marking, manufacturer information, test methods, and reporting, while clauses 9 and 10 define the angular response model, the clear-sky-based power-rating approach, and the procedures for low-FoV and high-FoV modules. Tables 1 and 2 define the standard test and operating conditions and the filtering criteria used in outdoor measurements. The figures show module geometry, irradiance terms, fitting examples, tracker geometry, FoV determination, and the sequence for deriving effective nominal power. Annex A explains module operating states and architectures, and Annex B gives a transient test sequence for internally tracked modules.
Buy Documents
iec63387-1{ed1.0}en - Hybrid CPV/PV modules: General characteristics and measurement procedures - Part 1: Performance measurements and power rating - Irradiance and temperature
iec63387-1{ed1.0}fr - Modules CPV/PV hybrides: caractéristiques générales et procédures de mesure - Partie 1: Mesurages de performances et caractéristiques assignées de puissance - Éclairement et température
Get Certified
Connect with accredited certification bodies for this standard

DNV
DNV is an independent assurance and risk management provider.

Lloyd's Register
Lloyd's Register is a global professional services organisation specialising in engineering and technology.

DNV Energy Systems
Energy and renewable energy certification.
Sponsored listings
Frequently Asked Questions
IEC 63387-1:2026 is a standard published by the International Electrotechnical Commission (IEC). Its full title is "Hybrid CPV/PV modules: General characteristics and measurement procedures - Part 1: Performance measurements and power rating - Irradiance and temperature". This standard covers: IEC 63387-1:2026 specifies the methods for evaluating CPV/PV hybrid module performance in terms of power rating. Standard conditions for assessing the power produced by the module and the procedures to measure the power as a function of AOI, irradiance, and temperature are described. A methodology for determining a set of characterization parameter values for the hybrid CPV/PV module (FoV) is also included. In order to compare the performance of different hybrid CPV/PV modules whose output is discontinuous and time-dependent, the concept of effective nominal power is introduced. This document is applicable to CPV/PV hybrid modules which include both solar cells designed to collect concentrated light (CPV cells array) and solar cells designed to collect diffuse or global light (PV cells array), the latter with bifacial or monofacial illumination. This document applies to hybrid CPV/PV modules with a geometrical concentration ratio > 3x for the CPV cells. For lower geometrical concentration ratio (≤ 3x), the IEC 60904-1 [11] and IEC 61853 series [9] apply.
IEC 63387-1:2026 specifies the methods for evaluating CPV/PV hybrid module performance in terms of power rating. Standard conditions for assessing the power produced by the module and the procedures to measure the power as a function of AOI, irradiance, and temperature are described. A methodology for determining a set of characterization parameter values for the hybrid CPV/PV module (FoV) is also included. In order to compare the performance of different hybrid CPV/PV modules whose output is discontinuous and time-dependent, the concept of effective nominal power is introduced. This document is applicable to CPV/PV hybrid modules which include both solar cells designed to collect concentrated light (CPV cells array) and solar cells designed to collect diffuse or global light (PV cells array), the latter with bifacial or monofacial illumination. This document applies to hybrid CPV/PV modules with a geometrical concentration ratio > 3x for the CPV cells. For lower geometrical concentration ratio (≤ 3x), the IEC 60904-1 [11] and IEC 61853 series [9] apply.
IEC 63387-1:2026 is classified under the following ICS (International Classification for Standards) categories: 27.160 - Solar energy engineering. The ICS classification helps identify the subject area and facilitates finding related standards.
IEC 63387-1:2026 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
Contents
- 1 Scope
- 2 Normative references
- 3 Terms and definitions
- 3.1 CPV/PV hybrid module
- 3.2 field of view
- 3.3 normalized angular response of a CPV/PV hybrid module
- 3.4 operational area
- 3.5 aperture area
- 3.6 total area
- 3.7 effective nominal power
- 4 Sampling
- 5 DUT labelling - Indelible marking
- 6 Preliminary information by manufacturer
- 7 Testing
- 8 Report
- 9 Power angular responsivity
- 9.1 General
- 9.2 Determination of the collection coefficient
- 10 Power rating condition
- 10.1 General
- 10.2 Outdoor power rating of CPV/PV hybrid modules to be installed on fixed structure
- 1 CPV 2 PV(inn) 3 PV(ext)
- 10.3 Outdoor power rating of CPV/PV hybrid modules installed on dual axis tracker
- Annex A
- Annex B
- Bibliography
INTRODUCTION
The IEC 61853 [9] and IEC 62670 series [10] establish requirements for evaluating, respectively, photovoltaic (PV) and concentrated photovoltaic (CPV) module performance, based on power, energy, and performance ratio (PR). They are applicable to most PV and CPV technologies; however they are not well suited to hybrid CPV/PV modules, whose performance can be a discontinuous function of the angle of incidence (AOI), whose geometry can include PV "dead" areas in addition to the module frame, and for which it is important to specify appropriate reference spectra for beam and diffuse components. The reasons for preparing this document are therefore related to the need to define specific terms and procedures for the performance measurement of hybrid CPV/PV modules. As some hybrid CPV/PV modules incorporate integrated tracking actuators and internal moving parts, the development of specific qualification standards for such modules is also envisaged.
Numbers in square brackets refer to the Bibliography.
1 Scope
This part of IEC 63387 specifies the methods for evaluating CPV/PV hybrid module performance in terms of power rating. Standard conditions for assessing the power produced by the module and the procedures to measure the power as a function of AOI, irradiance, and temperature are described. A methodology for determining a set of characterization parameter values for the hybrid CPV/PV module (FoV) is also included. In order to compare the performance of different hybrid CPV/PV modules whose output is discontinuous and timedependent, the concept of effective nominal power is introduced. This document is applicable to CPV/PV hybrid modules which include both solar cells designed to collect concentrated light (CPV cells array) and solar cells designed to collect diffuse or global light (PV cells array), the latter with bifacial or monofacial illumination. This document applies to hybrid CPV/PV modules with a geometrical concentration ratio > 3x for the CPV cells. For lower geometrical concentration ratio (≤ 3x), the IEC 60904-1 [11] and IEC 61853 series [9] apply.
2 Normative references
The following documents are referred to in the text in such a way that some or all of their content constitutes requirements of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.
IEC TS 60904-1-2, Photovoltaic devices - Part 1-2: Measurement of current-voltage characteristics of bifacial photovoltaic (PV) devices IEC TS 61836, Solar photovoltaic energy systems - Terms, definitions and symbols IEC 62108, Concentrator photovoltaic (CPV) modules and assemblies - Design qualification and type approval IEC 62670-1, Photovoltaic concentrators (CPV) - Performance testing - Part 1: Standard conditions IEC 62670-3, Photovoltaic concentrators (CPV) - Performance testing - Part 3: Performance measurements and power rating ISO 2859-1, Sampling procedures for inspection by attributes - Part 1: Sampling schemes indexed by acceptance quality limit (AQL) for lot-by-lot inspection
3 Terms and definitions
For the purposes of this document, the terms and definitions given in IEC TS 60904-1-2, IEC TS 61836, IEC 62108 and the following apply.
ISO and IEC maintain terminological databases for use in standardization athe following addresses:
- IEC Electropedia: available at https://www.electropedia.org/ - ISO Online browsing platform: available at https://www.iso.org/obp NOTE 1 Hybrid CPV/PV module can present areas which are intentionally not utilized for PV conversion. These areas are found in the case the hybrid CPV/PV module which use 2D-3D integrated tracking. Refer to Figure 1 and Annex A.
Figure 1 – Schematic of a hybrid CPV/PV module NOTE 2 In some CPV/PV hybrid modules the glass area (Area B) is covered by silicon or thin film cells. In this case, the hybrid CPV/PV module is said to have an "external" PV array and the area covered by the PV array is part of the operational area.
NOTE 3 An example of a normalized angular response of a CPV/PV hybrid module is reported in Figure 2.
3.1 CPV/PV hybrid module
module with solar cells designed to collect concentrated light (CPV cells array) and solar cells designed to collect diffuse or global light (PV cells array), with bifacial or monofacial illumination
3.2 field of view
FoV range of angles within which the normalized angular power value of the CPV cells remains within the 50 % of its maximum value Note 1 to entry: See 3.3.
3.3 normalized angular response of a CPV/PV hybrid module
CPV module angular power normalized to the maximum power condition, computed according to Formula (33)
Figure 2 – Example of the hybrid CPV/PV module power variation as a function of AOI, compared with the cos(AOI) behaviour (after [1])
3.4 operational area
area of the DUT designed for PV conversion Note 1 to entry: It concerns the lens area plus any further area covered by solar cells. Operational Area=Area A ( ) (1)
3.5 aperture area
area of the DUT from inside edge to inside edge of the DUT frame (as in IEC 62670-3) Aperture Area=Area A +Area B ( ) ( ) (2)
3.6 total area
module area given by the aperture area plus the module frame area Total Area=Area A +Area B +Area C ( ) ( ) ( ) (3)
3.7 effective nominal power
nominal power of a PV module whose performances are continuous function of AOI and that would produce the same yearly energy of the CPV/PV hybrid module under clear sky condition at reference temperature and latitude, respectively of 25 °C and of 45°
4 Sampling
For performance qualification testing, three specimens shall be selected at random from a production batch or batches in accordance with the procedure given in ISO 2859-1. For prototype devices which are not from production, sampling shall not apply, and this shall be noted in the test report.
When the results are used for nameplate rating, the modules or assemblies, hereafter referred to as the device under test (DUT), shall have been manufactured from specified materials and components in accordance with the relevant drawings and process sheets and shall have been subjected to the manufacturer's normal inspection, quality control, and production acceptance procedures. The DUT shall be complete in every detail and shall be accompanied by the manufacturer's handling and final assembly instructions manual regarding the recommended installation of any diodes, frames, brackets, etc.
5 DUT labelling - Indelible marking
Each module section shall carry the following clear and indelible markings:
- Name, monogram, or symbol of manufacturer.
- Type or model number.
- Serial number.
- Polarity of terminals or leads (colour coding is permissible).
- Maximum system voltage for which the module or assembly is suitable.
- Maximum output power and its tolerance at specified condition (AOI shall be specified if different from zero).
- The date, place of manufacture, and cell materials shall be marked, or be traceable from the serial number.
If representative samples are used, the same markings as on full-size products shall be included for all tests, and the marking should be capable of surviving all test sequences.
6 Preliminary information by manufacturer
The necessary values shall be provided by the manufacturer to the test laboratory for the purpose of measurement setup.
- Expected maximum power, maximum optical efficiency, V , and I at CSTC (concentrator oc sc standard testing conditions) and CSOC (concentrator standard operating conditions), as in IEC 62670-1, or HSTC (hybrid standard testing conditions) and HSOC (hybrid standard testing and operating conditions), as reported in Table 1 and effective nominal power (see Formula (32)).
- Field of view (FoV) (see Clause 3) or acceptance angle (when the module is installed on a dual axis tracker).
- Where relevant, the range of angles within which the CPV cell array is working. In case of asymmetrical refraction properties, measurements should be taken along two orthogonal angular directions with respect to the module normal.
- Installation instruction.
- Area ratio = Area(A)/Total Area (see Figure 1).
- β(t), and γ(t) angles related to the tracker where the hybrid CPV/PV module is intended to be installed (see 10.2.2).
7 Testing
The modules shall be subjected to the power and irradiance as a function of AOI, as well as a function of temperature as defined in Clause 10. In carrying out the tests, the tester shall observe the manufacturer's handling, mounting, and connection instructions. If the manufacturer's tracker is not used, the details of the alignment and tracker shall be documented in the test report.
8 Report
Following completion of the procedure, a report of the performance tests, with measured power characteristics shall be prepared by the test agency. Each test report shall include at least the following information:
- A title.
- Name and address of the test laboratory and location (including latitude, longitude and altitude) where the calibration or tests were carried out.
- Unique identification of the report and of each page.
- Name and address of client, where appropriate.
- Description and identification of the item calibrated or tested.
- Characterization and condition of the calibration or test item.
- Date of receipt of test item and date(s) of calibration or test, where appropriate.
- Identification of calibration or test method used.
- Reference to sampling procedure, where relevant.
- Any deviations from, additions to or exclusions from the calibration or test method, and any other information relevant to a specific calibration or test, such as environmental conditions. Details of the test procedure including the bias (e.g. maximum power or open circuit) maintained between test scans and how the data was filtered to meet the specified criteria.
- Measurements, examinations and derived results, including as a minimum table for I , I , sc max P , V , V , concentrator nominal operating cell temperature (CNOCT), values of the max oc max module thermal coefficients (temperature coefficients of absolute efficiency and power) the effective nominal power and the values for each of the three test modules at all reference power conditions.
- A statement of the estimated uncertainty of the calibration or test result, including uncertainty in CNOCT (where relevant).
- A statement as to whether the measured CSTC (HSTC), CSOC (HSOC) and nominal powers agree with the manufacturer's rated power range within the test laboratories measurement uncertainty (if appropriate).
- A statement concerning the addition of any blocking diode for the CPV array measurement to avoid damaging the CPV cells in case the current-voltage measurements proceed on the fourth quadrant and whether the IV curve measurements have been corrected for the voltage drop introduced by the blocking diode.
- A signature and title, or equivalent identification of the person(s) accepting responsibility for the content of the report, and the date of issue.
- Where relevant, a statement to the effect that the results relate only to the items calibrated or tested.
- A statement that the report shall not be reproduced except in full, without the written approval of the laboratory.
- Identification of the tracker used, the tracker alignment sensor, and the documented tracker error.
- Identification of the wind sensor used, the location of the wind sensor, the calibration of the wind sensor.
- Identification of the pyrheliometer used and the calibration of the pyrheliometer.
- Identification of the pyrometer used and the calibration of the pyrometer.
- Identification of the current sensor used.
- Identification of the voltage sensor used.
- Indication of module alignment method used (as recommended by manufacturer).
- indication of the point sensitive detector (used to measure the AOI)
- Indication of distance between NIP and module.
- A copy of this report shall be kept by the manufacturer for reference purposes.
9 Power angular responsivity
9.1 General
The most general expression to characterize the power of the hybrid CPV/PV module is the
power angular responsivity which should be preferred to the angular responsivity measurement based on the I , in order to take into account possible mismatch effects. sc
If instead of the power angular responsivity, the power density angular responsivity is considered (which is expressed in watts per square metres), the coefficients reported in Formula (4) are efficiency terms.
For front illumination, it holds:
P θT, ε θT,⋅DIFFTI θ+γ θT,⋅DTI θ+φ θT,⋅+GTI θ γ θT,⋅DTI θ ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) (4) front PV PV PVext CPV
DIFFTI θ GTI θ−DTI θ ( ) ( ) ( ) (5)
DTI(θ) DNI( 0)⋅ cosθ (6)
where:
P θT, is the power angular responsivity generated by the CPV/PV hybrid module,
front expressed in Watts (W), when the AOI is θ; θ is the angle of incidence (AOI); ε θT, is the angular fraction of diffused light absorbed by the PV cells, the unit is in
PV
square metres (m ); is the angular fraction of direct light scattered or focused by lenses, absorbed by γ θT,
PV
the PV cells, expressed in square metres (m ), respectively when θ is inside or outside the FoV; is the angular fraction of global light absorbed by the external PV cells, φ (θT, ) PVext
expressed in square metres (m ); is the angular fraction of DNI light absorbed by the CPV cells, expressed in γ θT,
CPV
square metres (m ); DTI θ is the direct tilted irradiance (component of the direct normal irradiance along
the module normal expressed in Watts per square metres (W/m ) on a tilted module); DNI 0
is the direct normal irradiance; GTI θ
is the global tilted irradiance, expressed in Watts per square metres (W/m ) on a tilted module;
is the diffused tilted irradiance, expressed in Watts per square metres (W/m ) on DIFFTI θ
a tilted module; T is the temperature of the cells. CPV cells, inner PV cells and external (ext) PV cells are characterized by a different T value.
NOTE A schematic of the irradiance terms used in Formula (4) is reported in Figure 3.
9.2 Determination of the collection coefficient
ε θT,, γ θT,,φ θT, and γ θT, are called collection coefficients. The power
PV PV PVext CPV angular responsivity is measured according to the procedures reported in 10.2.7 and 10.2.8. The values are then translated to 25 °C according to 10.2.4.
NOTE 1 Examples of fitting of Formula (7) and Formula (8) are reported in Figure 4. NOTE 2 An example of fitting of Formula (9) is reported in Figure 5. NOTE 3 An example of fitting of Formula (12) is reported in Figure 6.
For the PV cells (inside the module), it holds:
P (θT, ) DTI θ
front,PV γ (θT, )−+ε (θT, ) ε (θT, ) (7)
PV PV PV GTI(θ) GTI(θ)
Figure 3 – Schematic of the irradiance terms used in Formula (4) for the general case of a hybrid CPV/PV module mounted on a tilted fixed plane The following formulae apply for front illumination, and θ inside the FoV (i.e. for hybrid CPV/PV condition, see Annex A).
The collection coefficient for diffused radiation, can be considered almost constant ε (θT, ) PV (as it is very weakly dependent on AOI) and it can be computed at normal incidence from the fitting of Formula (7)) by assuming in first approximation . Once is γ (θT,0)= P PV front,PV translated to 25 °C and given εθ=0°°, 25 , the approximated value of γθ,25°C can then
PV PV be computed by rearranging Formula (7), and getting a polynomial fitting of Formula (8):
P θC,25° GTI θ
front,PV γθ,25°=C +ε θ=0°,25°C 1− ( ) ( ) (8) PV PV
DTI(θ) DTI(θ)
a) b)
Figure 4 – Example of fitting of Formula (7) and Formula (8) for the determination of the collection coefficients: a) and b) εθ, 25° γθ,25°C
PV PV
can be computed through a polynomial fitting of Formula (9):
φ θT,
PVext P (θT, ) front,ext φ (θT,·) φ τ(θ) (9) PVext PVext GTI(θ)
where τ θ is the transmission coefficient reported in Formula 5 of IEC 61853-2:2016 [15], with
a = 0,18.
r
−cosAOI 1− exp
a r τ AOI =
(10)
−1 1− exp
a r
Once P (θT, ) is translated to 25 °C and by considering the measurements performed in a front,ext reduced AOI range, φ can be computed by the polynomial fitting of Formula (9) by PVext assuming τ(AOI ) =1. The value of is then simply computed by multiplying φ φ θT,
PVext PVext by , given by Formula (10).
τ(θ)
Figure 5 – Example of fitting of Formula (9), with τ AOI = 1 for the determination of the
collection coefficient φ PVext For the CPV cells, it holds:
P θT,,γ θT⋅DTI θ ( ) ( ) ( ) (11) front,CPV CPV
can be obtained from a (four-grade) polynomial fitting of Formula (11). Once γ (θT, ) CPV P (θT, ) is translated to 25 °C, the polynomial fitting of Formula (11) gives γ θC,25° .
front,CPV CPV
For front illumination, and for θ> FoV (i.e for global PV condition, see Annex A), for the inner PV cells can be computed by fitting Formula (12), by assuming equal to the γ (θT, ) ε (θT, ) PV PV value determined for θ< FoV :
P θT, DTI θ
front,PV γ θT,−+ε θT, ε θT, ( ( ) ( )) ( ) (12) PV PV PV GTI θ GTI θ
P θT, can be computed according to Formula (9). A reproducible moving plane position
front,ext shall be found also for AOI out of the FoV, (where the inner tracker control could not be operative) to assure reproducible measurement on the inner PV array.
Figure 6 – Example of fitting of Formula (12) for the determination of the collection coefficient γθ,25°
CPV For back (rear) illumination, only the PV cells convert the solar light:
...
Contents
- 1 Domaine d’application
- 2 Références normatives
- 3 Termes et définitions
- 3.1 module CPV/PV hybride
- 3.2 champ de vision
- 3.3 réponse angulaire normalisée d’un module CPV/PV hybride
- 3.4 surface opérationnelle
- 3.5 surface d’entrée
- 3.6 surface totale
- 3.7 puissance nominale effective
- 4 Échantillonnage
- 5 Étiquetage du DUT – Marquage indélébile
- 6 Informations préliminaires mentionnées par le fabricant
- 7 Méthodes d’essai
- 8 Rapport
- 9 Sensibilité angulaire de puissance
- 9.1 Généralités
- 9.2 Détermination des coefficients de collecte
- 10 Condition de caractéristiques assignées de puissance
- 10.1 Généralités
- 10.2 Caractéristiques assignées de puissance en extérieur des modules CPV/PV
- 1 CPV 2 PV(inn) 3 PV(ext)
- 10.3 Caractéristiques assignées de puissance en extérieur des modules CPV/PV
- Annexe A
- Annexe B
- Bibliographie
INTRODUCTION
Les séries IEC 61853 [9] et IEC 62670 [10] établissent respectivement les exigences relatives à l’évaluation des performances des modules photovoltaïques (PV) et photovoltaïques à concentration (CPV, Concentrated Photovoltaics) sur la base de la puissance, de l’énergie et du coefficient de performance (PR, Performance Ratio). Elles s’appliquent à la plupart des technologies PV et CPV; en revanche, elles ne sont pas bien adaptées aux modules CPV/PV hybrides, dont les performances peuvent représenter une fonction discontinue de l’angle d’incidence (AOI, Angle Of Incidence), dont la géométrie peut inclure une zone "morte" PV en plus du châssis du module, et pour lesquels il est important de spécifier un spectre de référence approprié pour le faisceau et les composantes diffuses.
La rédaction du présent document s’explique donc par la nécessité de définir des procédures et termes spécifiques pour mesurer les performances de modules CPV/PV hybrides. Certains modules CPV/PV hybrides comportant des actionneurs de suivi solaire intégré et des parties mobiles internes, il est également envisagé d’élaborer des normes de qualification spécifiques pour ces modules.
Les chiffres entre crochets renvoient à la Bibliographie.
1 Domaine d’application
La présente partie de l’IEC 63387 spécifie les méthodes d’évaluation des performances des modules CPV/PV hybrides en ce qui concerne les caractéristiques assignées de puissance. Les conditions normales d’évaluation de la puissance générée par le module et des procédures de mesure de la puissance en fonction de l’AOI, de l’éclairement et de la température sont définies. Une méthodologie visant à définir un ensemble de valeurs pour les paramètres de caractérisation du module CPV/PV hybride (champ de vision) est également incluse. Pour comparer les performances des différents modules CPV/PV hybrides dont la sortie est discontinue et fonction du temps, le concept de puissance nominale effective a été introduit. Le présent document a été rédigé de façon à pouvoir s’appliquer aux modules CPV/PV hybrides équipés de cellules photovoltaïques conçues pour récupérer la concentration de lumière (ensemble de cellules CPV) et de cellules photovoltaïques conçues pour récupérer la lumière diffuse ou globale (ensemble de cellules PV), ces dernières avec un éclairage biface ou monoface. Le présent document s’applique aux modules CPV/PV hybrides dont le rapport de concentration géométrique est supérieur à 3 pour les cellules CPV. Pour les rapports de concentration géométrique inférieurs (≤ 3), les séries IEC 60904-1 [11] et IEC 61853 [9] s’appliquent.
2 Références normatives
Les documents suivants sont cités dans le texte de sorte qu’ils constituent, pour tout ou partie de leur contenu, des exigences du présent document. Pour les références datées, seule l’édition citée s’applique. Pour les références non datées, la dernière édition du document de référence s’applique (y compris les éventuels amendements).
IEC TS 60904-1-2, Photovoltaic devices - Part 1-2: Measurement of current-voltage characteristics of bifacial photovoltaic (PV) devices (disponible en anglais seulement) IEC TS 61836, Solar photovoltaic energy systems - Terms, definitions and symbols (disponible en anglais seulement) IEC 62108, Modules et ensembles photovoltaïques à concentration - Qualification de la conception et homologation IEC 62670-1, Concentrateurs photovoltaïques (CPV) - Essai de performances - Partie 1:
Conditions normales IEC 62670-3, Concentrateurs photovoltaïques (CPV) - Essai de performances - Partie 3:
Mesurages de performances et rapport de puissance ISO 2859-1, Règles d’échantillonnage pour les contrôles par attributs - Partie 1: Procédures d’échantillonnage pour les contrôles lot par lot, indexés d’après le niveau de qualité acceptable (NQA)
3 Termes et définitions
Pour les besoins du présent document, les termes et les définitions de l’IEC TS 60904-1-2, l’IEC TS 61836, l’IEC 62108 ainsi que les suivants s’appliquent. L’ISO et l’IEC tiennent à jour des bases de données terminologiques destinées à être utilisées en normalisation, consultables aux adresses suivantes:
- IEC Electropedia: disponible à l’adresse https://www.electropedia.org/
- ISO Online browsing platform: disponible à l’adresse https://www.iso.org/obp
NOTE 1 Le module CPV/PV hybride peut présenter des surfaces qui ne sont pas utilisées volontairement pour la conversion PV. Ces surfaces sont présentes si le module CPV/PV hybride utilise un suivi solaire intégré 2D-3D. Voir la Figure 1 et l’Annexe A.
Figure 1 – Schéma d’un module CPV/PV hybride NOTE 2 Dans certains modules CPV/PV hybrides, la surface du verre (Surface B) est recouverte de cellules en silicium ou de couche mince. Dans ce cas, le module CPV/PV hybride est présenté comme ayant un groupe photovoltaïque "externe", la surface couverte par le groupe photovoltaïque faisant partie intégrante de la surface opérationnelle.
NOTE 3 Un exemple de réponse angulaire normalisée d’un module CPV/PV hybride est rapporté à la Figure 2.
3.1 module CPV/PV hybride
module combinant des cellules photovoltaïques à concentration conçues pour recevoir la lumière concentrée (ensemble de cellules CPV) et des cellules photovoltaïques conventionnelles conçues pour récupérer la lumière globale ou diffuse (ensemble de cellules PV) avec un éclairage monoface ou biface
3.2 champ de vision
FoV plage angulaire dans laquelle la valeur de puissance angulaire normalisée des cellules CPV reste dans les limites de 50 % de sa valeur maximale Note 1 à l’article: Voir en 3.3.
Note 2 à l’article: L’abréviation FoV est dérivée du terme anglais développé correspondant "field of view".
3.3 réponse angulaire normalisée d’un module CPV/PV hybride
puissance angulaire du module CPV normalisée par rapport à la puissance maximale, calculée selon la Formule (33)
Figure 2 – Exemple de variation de puissance du module CPV/PV hybride en fonction de l’AOI, par rapport au comportement cos(AOI) (d’après [1])
3.4 surface opérationnelle
zone du DUT conçue pour la conversion PV Note 1 à l’article: Il s’agit de la surface de lentille à laquelle s’ajoutent toutes les autres surfaces couvertes par les cellules photovoltaïques.
Surface opérationnelle = Surface(𝐴𝐴) (1)
3.5 surface d’entrée
surface comprise entre les bords intérieurs du châssis du dispositif en essai (voir l’IEC 62670-3) Surface d'entrée = Surface(𝐴𝐴) + Surface(𝐵𝐵) (2)
3.6 surface totale
surface du module égale à la surface d’entrée plus la surface du châssis du module Surface totale = Surface(𝐴𝐴) + Surface(𝐵𝐵) + Surface(𝐶𝐶) (3)
3.7 puissance nominale effective
puissance nominale d’un module photovoltaïque dont les performances sont une fonction continue de l’AOI et qui produirait la même énergie annuelle que le module CPV/PV hybride sous ciel clair à la température et à la latitude de référence de 25 °C et 45°, respectivement
4 Échantillonnage
Pour les essais de qualification de performance, trois spécimens doivent être prélevés au hasard dans un ou plusieurs lots de production, conformément à la procédure décrite dans l’ISO 2859-1. Pour les dispositifs prototypes qui ne sont pas issus de la production, l’échantillonnage ne doit pas s’appliquer et cela doit être consigné dans le rapport d’essai.
Si les résultats sont utilisés pour les caractéristiques assignées de la plaque signalétique, les modules ou ensembles, appelés ci-après dispositif en essai (DUT, Device Under Test), doivent avoir été fabriqués à partir de matériaux et de composants spécifiés, conformément aux schémas et aux descriptifs des procédés de fabrication correspondants. Ils doivent également avoir été soumis au contrôle normal du fabricant, à un contrôle qualité et aux procédures d’acceptation de la production. Le DUT doit être complet, jusque dans les moindres détails, et doit être accompagné des instructions de manipulation et d’assemblage final du fabricant, en ce qui concerne l’installation recommandée des diodes, châssis, supports, etc.
5 Étiquetage du DUT – Marquage indélébile
Chaque section du module doit porter clairement et de manière indélébile les marquages suivants:
- le nom, le monogramme ou le symbole du fabricant;
- le type ou le numéro du modèle;
- le numéro de série;
- la polarité des bornes de sortie ou des conducteurs (un code de couleur est admis);
- la tension maximale de système pour laquelle le module ou l’ensemble est adéquat;
- la puissance de sortie maximale et sa tolérance à la condition spécifiée (l’AOI doit être spécifié s’il n’est pas nul);
- la date, le lieu de fabrication et les matériaux de la cellule doivent être indiqués ou la traçabilité de ces informations doit être assurée à partir du numéro de série. Si des échantillons représentatifs sont utilisés, les mêmes marquages que sur les produits en grandeur réelle doivent être inclus pour tous les essais, et il convient que le marquage puisse résister à toutes les séquences d’essais.
6 Informations préliminaires mentionnées par le fabricant
Le fabricant doit fournir au laboratoire d’essai les valeurs nécessaires pour le montage de mesure:
- la puissance maximale prévue, le rendement optique maximal, V , et I aux conditions oc sc d’essais normales du concentrateur (CSTC, Concentrator Standard Test Conditions) et aux conditions de fonctionnement normales du concentrateur (CSOC, Concentrator Standard Operating Conditions) comme indiqué dans l’IEC 62670-1, ou aux conditions d’essais normales hybrides (HSTC, Hybrid Standard Testing Conditions) et aux conditions de fonctionnement normales hybrides (HSOC, Hybrid Standard Testing And Operating Conditions), comme indiqué dans le Tableau 1, et la puissance nominale effective (voir la Formule (32));
- le champ de vision (FoV) (voir l’Article 3) ou l’angle d’admission (si le module est installé sur un suiveur solaire à deux axes);
- le cas échéant, la plage angulaire de fonctionnement de l’ensemble de cellules CPV. En cas de réfraction asymétrique, il convient d’effectuer les mesurages selon deux directions angulaires orthogonales par rapport à la normale du module;
- les instructions d’installation;
- rapport de surface = Surface(A)/Surface totale (voir la Figure 1 );
- les angles β(t) et γ(t) liés au suiveur solaire sur lequel le module CPV/PV hybride est destiné à être installé (voir en 10.2.2).
7 Méthodes d’essai
Les modules doivent être soumis à la puissance et à l’éclairement en fonction de l’AOI et en fonction de la température telle que définie dans l’Article 10. En procédant aux essais, les instructions de manipulation, de nettoyage et de raccordement du fabricant doivent être respectées. Si le suiveur solaire du fabricant n’est pas utilisé, les détails relatifs à l’alignement et au suiveur solaire doivent être consignés dans le rapport d’essai.
8 Rapport
À l’issue de la procédure, l’agence qui procède aux essais doit établir un rapport des essais de performance, avec les caractéristiques de puissance mesurées. Chaque rapport d’essai doit inclure au moins les informations suivantes:
- titre;
- nom et adresse du laboratoire d’essai et le lieu (y compris latitude, longitude et altitude) de réalisation de l’étalonnage ou des essais;
- identification unique du rapport et de chaque page;
- nom et adresse du client, le cas échéant;
- description et identification de l’élément étalonné ou soumis à essai;
- caractérisation et conditions d’étalonnage ou état de l’élément soumis à essai;
- date de réception de l’élément soumis à essai et la ou les dates d’étalonnage ou d’essai, le cas échéant;
- identification de la méthode d’étalonnage ou d’essai utilisée;
- référence à la procédure d’échantillonnage, si cela est pertinent;
- écarts, compléments ou exclusions éventuels de la méthode d’étalonnage ou d’essai, et toute autre information correspondant à un étalonnage ou essai spécifique, comme les conditions d’environnement. Les détails de la procédure d’essai, y compris le biais (puissance maximale ou circuit ouvert, par exemple) maintenu entre les balayages d’essai et la manière dont les données ont été filtrées pour satisfaire aux critères spécifiés;
- mesurages, examens et résultats obtenus, incluant au minimum un tableau pour I , I , sc max P , V , V , la température nominale de fonctionnement des cellules à concentration max oc max (CNOCT, Concentrator Nominal Operating Cell Temperature), les valeurs des coefficients thermiques du module (coefficients de température d’efficacité absolue et de puissance), la puissance nominale effective et les valeurs pour chacun des trois modules d’essai dans toutes les conditions de puissance de référence;
- déclaration de l’incertitude estimée de l’étalonnage ou du résultat d’essai, y compris l’incertitude de la CNOCT (le cas échéant);
- déclaration indiquant si les valeurs CSTC (HSTC), CSOC (HSOC) et puissances nominales mesurées correspondent à la plage de puissances assignées du fabricant dans les limites de l’incertitude de mesure des laboratoires d’essai (le cas échéant);
- déclaration concernant l’ajout d’une diode antiretour pour mesurer le groupe CPV, afin d’éviter d’endommager les cellules CPV au cas où les mesurages de courant-tension se poursuivent sur le quatrième quadrant, et indiquant si les mesures de la courbe IV ont été corrigées pour tenir compte de la chute de tension introduite par la diode antiretour;
- signature et fonction, ou identification équivalente de la ou des personnes assumant la responsabilité du contenu du rapport, et date de publication;
- lorsque cela est pertinent, déclaration stipulant que les résultats se rapportent uniquement aux éléments soumis à essai;
- déclaration indiquant que le rapport ne doit pas être reproduit, sauf en totalité, sans l’approbation écrite du laboratoire;
- identification du suiveur solaire utilisé, du capteur d’alignement du suiveur solaire et de l’erreur de suiveur solaire documentée;
- identification, emplacement et étalonnage du capteur de vent utilisé;
- identification et étalonnage du pyrhéliomètre utilisé;
- identification et étalonnage du pyromètre utilisé;
- identification du capteur de courant utilisé;
- identification du capteur de tension utilisé;
- indication de la méthode d’alignement du module utilisée (selon les recommandations du fabricant);
- indication du détecteur sensible aux points (DSP), qui permet de mesurer l’AOI;
- indication de la distance entre le pyrhéliomètre sous incidence normale (NIP, Normal Incident Pyrheliometer) et le module;
- copie de ce rapport à conserver en référence par le fabricant.
9 Sensibilité angulaire de puissance
9.1 Généralités
L’expression la plus générale pour caractériser la puissance du module CPV/PV hybride est la
sensibilité angulaire de puissance , qu’il convient de préférer au mesurage de la sensibilité angulaire basé sur I , afin de tenir compte des effets possibles de désadaptation. sc Pour l’éclairage avant, il s’agit de:
P θT, ε θT,⋅ DIFFTI θ+ γ θT,⋅ DTI θ+ φ θT,⋅+GTI θ γ θT,⋅ DTI θ (4)
front PV PV PVext CPV
DIFFTI θ GTI θ− DTI θ ( ) ( ) ( ) (5)
DTI θ DNI 0⋅ cosθ ( ) ( ) (6)
où:
P θT, ( ) est la sensibilité angulaire de puissance générée par le module CPV/PV hybride, front exprimée en watts (W), lorsque l’AOI est θ; θ est l’angle d’incidence (AOI); est la fraction angulaire de la lumière diffuse absorbée par les cellules PV, l’unité ε θT,
PV
étant le mètre carré (m ); est la fraction angulaire de la lumière directe diffusée ou focalisée par les γ θT,
PV
lentilles, absorbée par les cellules PV, exprimée en mètres carrés (m ), respectivement lorsque θ est à l’intérieur ou à l’extérieur du champ de vision; est la fraction angulaire de la lumière globale absorbée par les cellules PV φ (θT, ) PVext
externes, exprimée en mètre carré (m ); γ θT, est la fraction angulaire de la lumière de l’éclairement normal direct (DNI, Direct
CPV Normal Irradiance) absorbée par les cellules PV, l’unité étant le mètre
carré (m );
Si la sensibilité angulaire de densité de puissance est prise en compte (exprimée en watts par mètre carré) en lieu et place de la sensibilité angulaire de puissance, les coefficients rapportés dans la Formule (4) sont des termes d’efficacité.
est l’éclairement incliné direct (composante de l’éclairement normal direct le long DTI(θ)
de la normale du module exprimée en watts par mètre carré (W/m ) sur un module incliné); DNI 0
est l’éclairement normal direct; GTI θ
est l’éclairement incliné global, exprimé en Watts par mètre carré (W/m ) sur un module incliné;
est l’éclairement incliné diffus, exprimé en Watts par mètre carré (W/m ) sur un DIFFTI θ
module incliné; T est la température des cellules. Les cellules CPV, les cellules PV internes et les cellules PV externes (ext) sont caractérisées par une valeur T différente. NOTE Un schéma des termes d’éclairement utilisés dans la Formule (4) est indiqué à la Figure 3.
9.2 Détermination des coefficients de collecte
ε θT,, γ θT,,φ θT, et γ θT, sont appelés coefficients de collecte. La sensibilité
PV PV PVext CPV angulaire de puissance est mesurée selon les procédures indiquées en 10.2.7 et 10.2.8. Les valeurs sont ensuite converties à 25 °C conformément à 10.2.4. NOTE 1 Des exemples d’ajustement de la Formule (7) et de la Formule (8) sont représentés à la Figure 4. NOTE 2 Un exemple d’ajustement de la Formule (9) est représenté à la Figure 5. NOTE 3 Un exemple d’ajustement de la Formule (12) est représenté à la Figure 6. Pour les cellules PV (à l’intérieur du module), il s’agit de:
P θT, DTI θ
front,PV γ θT,−+ε θT, ε θT, ( ( ) ( )) ( ) (7) PV PV PV GTI θ GTI θ
Figure 3 – Schéma des termes d’éclairement utilisés dans la Formule (4) pour le cas général d’un module CPV/PV hybride monté sur un plan fixe incliné Les formules suivantes s’appliquent pour l’éclairage avant et θ à l’intérieur du champ de vision (c’est-à-dire pour la condition CPV/PV hybride, voir l’Annexe A).
Le coefficient de collecte du rayonnement diffus, , peut être considéré comme quasi ε (θT, ) PV constant (car très faiblement dépendant de l’AOI) et peut être calculé à incidence normale à partir de l’ajustement de la Formule (7)) en prenant γ θT,0= en première approximation.
PV Dès que est converti à 25 °C et compte tenu de , la valeur approximative P εθ(=0°°, 25) front,PV PV de γθ,25°C peut alors être calculée en réorganisant la Formule (7) et en procédant à un
PV ajustement polynomial de la Formule (8):
P θC,25° GTI θ
front,PV γθ,25°=C + ε θ=0°,25°C 1− ( ) ( ) (8) PV PV
DTI θ DTI θ
a) b)
Figure 4 – Exemple d’ajustement de la Formule (7) et de la Formule (8) pour déterminer les coefficients de collecte: a) et b) εθ, 25° γθ,25°C
PV PV peut être calculé par un ajustement polynomial de la Formule (9):
φ (θT, ) PVext P θT,
front,ext φ θT,·φ τ θ ( ) ( ) (9) PVext PVext GTI θ
où τ θ est le coefficient de transmission indiqué dans la Formule 5 de l’IEC 61853-2:2016
[15], avec a = 0,18.
r
−cos AOI 1− exp
a r τ AOI =
(10)
−1 1− exp
a r
Dès que P (θT, ) est converti à 25 °C et en tenant compte des mesurages réalisés dans front,ext une plage AOI réduite, φ peut être calculé par l’ajustement polynomial de la Formule (9) PVext en prenant pour hypothèse τ(AOI ) = 1. La valeur de est alors simplement calculée φ (θT, ) PVext en multipliant φ par , donnée par la Formule (10).
τ θ
PVext
Figure 5 – Exemple d’ajustement de la Formule (9), avec τ AOI = 1 pour la
détermination du coefficient de collecte φ PVext Pour les cellules CPV, il s’agit de:
P θT,,γ θT⋅ DTI θ ( ) ( ) ( ) (11) front,CPV CPV
peut être obtenu à partir d’un ajustement polynomial (classe quatre) de la γ (θT, ) CPV Formule (11). Dès que P (θT, ) est converti à 25 °C, l’ajustement polynomial de la front,CPV Formule (11) donne γ θC,25° .
...