IEC 60730-2-12:2005
(Main)Automatic electrical controls for household and similar use - Part 2-12: Particular requirements for electrically operated door locks
Automatic electrical controls for household and similar use - Part 2-12: Particular requirements for electrically operated door locks
In general, this part of IEC 60730 applies to electrically operated door locks intended to prevent the opening of doors in equipment for household and similar use.
Dispositifs de commande électrique automatiques à usage domestique et analogue - Partie 2-12: Règles particulières pour les serrures électriques de portes
De façon générale, la présente partie de la CEI 60730 s'applique aux serrures électriques de portes prévues pour empêcher l'ouverture des portes de matériels électrodomestiques et analogues.
General Information
Relations
Standards Content (Sample)
NORME CEI
INTERNATIONALE
IEC
60730-2-12
INTERNATIONAL
Deuxième édition
STANDARD
Second edition
2005-08
Dispositifs de commande électrique automatiques
à usage domestique et analogue –
Partie 2-12:
Règles particulières pour les serrures
électriques de portes
Automatic electrical controls for
household and similar use –
Part 2-12:
Particular requirements for electrically
operated door locks
Numéro de référence
Reference number
CEI/IEC 60730-2-12:2005
Numérotation des publications Publication numbering
Depuis le 1er janvier 1997, les publications de la CEI As from 1 January 1997 all IEC publications are
sont numérotées à partir de 60000. Ainsi, la CEI 34-1 issued with a designation in the 60000 series. For
devient la CEI 60034-1. example, IEC 34-1 is now referred to as IEC 60034-1.
Editions consolidées Consolidated editions
Les versions consolidées de certaines publications de la The IEC is now publishing consolidated versions of its
CEI incorporant les amendements sont disponibles. Par publications. For example, edition numbers 1.0, 1.1
exemple, les numéros d’édition 1.0, 1.1 et 1.2 indiquent and 1.2 refer, respectively, to the base publication,
respectivement la publication de base, la publication de the base publication incorporating amendment 1 and
base incorporant l’amendement 1, et la publication de the base publication incorporating amendments 1
base incorporant les amendements 1 et 2. and 2.
Informations supplémentaires Further information on IEC publications
sur les publications de la CEI
Le contenu technique des publications de la CEI est The technical content of IEC publications is kept
constamment revu par la CEI afin qu'il reflète l'état under constant review by the IEC, thus ensuring that
actuel de la technique. Des renseignements relatifs à the content reflects current technology. Information
cette publication, y compris sa validité, sont dispo- relating to this publication, including its validity, is
nibles dans le Catalogue des publications de la CEI available in the IEC Catalogue of publications
(voir ci-dessous) en plus des nouvelles éditions, (see below) in addition to new editions, amendments
amendements et corrigenda. Des informations sur les and corrigenda. Information on the subjects under
sujets à l’étude et l’avancement des travaux entrepris consideration and work in progress undertaken by the
par le comité d’études qui a élaboré cette publication, technical committee which has prepared this
ainsi que la liste des publications parues, sont publication, as well as the list of publications issued,
également disponibles par l’intermédiaire de: is also available from the following:
• Site web de la CEI (www.iec.ch) • IEC Web Site (www.iec.ch)
• Catalogue des publications de la CEI • Catalogue of IEC publications
Le catalogue en ligne sur le site web de la CEI The on-line catalogue on the IEC web site
(www.iec.ch/searchpub) vous permet de faire des (www.iec.ch/searchpub) enables you to search by a
recherches en utilisant de nombreux critères, variety of criteria including text searches,
comprenant des recherches textuelles, par comité technical committees and date of publication. On-
d’études ou date de publication. Des informations en line information is also available on recently
ligne sont également disponibles sur les nouvelles issued publications, withdrawn and replaced
publications, les publications remplacées ou retirées, publications, as well as corrigenda.
ainsi que sur les corrigenda.
• IEC Just Published • IEC Just Published
Ce résumé des dernières publications parues This summary of recently issued publications
(www.iec.ch/online_news/justpub) est aussi dispo- (www.iec.ch/online_news/justpub) is also available
nible par courrier électronique. Veuillez prendre by email. Please contact the Customer Service
contact avec le Service client (voir ci-dessous) Centre (see below) for further information.
pour plus d’informations.
• Service clients • Customer Service Centre
Si vous avez des questions au sujet de cette If you have any questions regarding this
publication ou avez besoin de renseignements publication or need further assistance, please
supplémentaires, prenez contact avec le Service contact the Customer Service Centre:
clients:
Email: custserv@iec.ch Email: custserv@iec.ch
Tél: +41 22 919 02 11 Tel: +41 22 919 02 11
Fax: +41 22 919 03 00 Fax: +41 22 919 03 00
.
NORME CEI
INTERNATIONALE
IEC
60730-2-12
INTERNATIONAL
Deuxième édition
STANDARD
Second edition
2005-08
Dispositifs de commande électrique automatiques
à usage domestique et analogue –
Partie 2-12:
Règles particulières pour les serrures
électriques de portes
Automatic electrical controls for
household and similar use –
Part 2-12:
Particular requirements for electrically
operated door locks
IEC 2005 Droits de reproduction réservés Copyright - all rights reserved
Aucune partie de cette publication ne peut être reproduite ni No part of this publication may be reproduced or utilized in any
utilisée sous quelque forme que ce soit et par aucun procédé, form or by any means, electronic or mechanical, including
électronique ou mécanique, y compris la photocopie et les photocopying and microfilm, without permission in writing from
microfilms, sans l'accord écrit de l'éditeur. the publisher.
International Electrotechnical Commission, 3, rue de Varembé, PO Box 131, CH-1211 Geneva 20, Switzerland
Telephone: +41 22 919 02 11 Telefax: +41 22 919 03 00 E-mail: inmail@iec.ch Web: www.iec.ch
CODE PRIX
P
PRICE CODE
Commission Electrotechnique Internationale
International Electrotechnical Commission
МеждународнаяЭлектротехническаяКомиссия
Pour prix, voir catalogue en vigueur
For price, see current catalogue
– 2 – 60730-2-12 CEI:2005
SOMMAIRE
AVANT-PROPOS .4
Domaine d'application et références normatives.8
2 Définitions .10
3 Exigences générales.12
4 Généralités sur les essais.12
5 Caractéristiques nominales .12
6 Classification .12
7 Informations .14
8 Protection contre les chocs électriques .14
9 Dispositions en vue de la mise à la terre .14
10 Bornes et connexions .16
11 Exigences de construction .16
12 Résistance à l'humidité et à la poussière.16
13 Résistance d'isolement et rigidité diélectrique .16
14 Echauffements.16
15 Tolérances de fabrication et dérive .16
16 Contraintes climatiques.16
17 Endurance .16
18 Résistance mécanique.22
19 Pièces filetées et connexions .22
20 Lignes de fuite, distances dans l'air et distances à travers l'isolation solide.22
21 Résistance à la chaleur, au feu et aux courants de cheminement .22
22 Résistance à la corrosion.24
23 Exigences de compatibilité électromagnétique (CEM) – Emission.24
24 Eléments constituants.24
25 Fonctionnement normal .24
26 Exigences de compatibilité électromagnétique (CEM) – Immunité.24
27 Fonctionnement anormal.24
28 Guide sur l'utilisation des coupures électroniques .24
Annexes.26
Annexe H (normative) Exigences pour les dispositifs de commande électroniques .26
60730-2-12 IEC:2005 – 3 –
CONTENTS
FOREWORD.5
Scope and normative references.9
2 Definitions .11
3 General requirements .13
4 General notes on tests.13
5 Rating.13
6 Classification .13
7 Information .15
8 Protection against electric shock.15
9 Provision for protective earthing.15
10 Terminals and terminations.17
11 Constructional requirements .17
12 Moisture and dust resistance .17
13 Electric strength and insulation resistance.17
14 Heating.17
15 Manufacturing deviation and drift .17
16 Environmental stress .17
17 Endurance .17
18 Mechanical strength.23
19 Threaded parts and connections .23
20 Creepage distances, clearances and distances through solid insulation.23
21 Resistance to heat, fire and tracking .23
22 Resistance to corrosion .25
23 Electromagnetic compatibility (EMC) requirements – emission .25
24 Components .25
25 Normal operation .25
26 Electromagnetic compatibility (EMC) requirements – immunity .25
27 Abnormal operation.25
28 Guidance on the use of electronic disconnection .25
Annexes.27
Annex H (normative) Requirements for electronic controls .27
– 4 – 60730-2-12 CEI:2005
COMMISSION ÉLECTROTECHNIQUE INTERNATIONALE
____________
DISPOSITIFS DE COMMANDE ÉLECTRIQUE AUTOMATIQUES
À USAGE DOMESTIQUE ET ANALOGUE –
Partie 2-12: Règles particulières pour
les serrures électriques de portes
AVANT-PROPOS
1) La Commission Electrotechnique Internationale (CEI) est une organisation mondiale de normalisation composée
de l'ensemble des comités électrotechniques nationaux (Comités nationaux de la CEI). La CEI a pour objet de
favoriser la coopération internationale pour toutes les questions de normalisation dans les domaines de
l'électricité et de l'électronique. A cet effet, la CEI – entre autres activités – publie des Normes internationales,
des Spécifications techniques, des Rapports techniques, des Spécifications accessibles au public (PAS) et des
Guides (ci-après dénommés "Publication(s) de la CEI"). Leur élaboration est confiée à des comités d'études,
aux travaux desquels tout Comité national intéressé par le sujet traité peut participer. Les organisations
internationales, gouvernementales et non gouvernementales, en liaison avec la CEI, participent également aux
travaux. La CEI collabore étroitement avec l'Organisation Internationale de Normalisation (ISO), selon des
conditions fixées par accord entre les deux organisations.
2) Les décisions ou accords officiels de la CEI concernant les questions techniques représentent, dans la mesure
du possible, un accord international sur les sujets étudiés, étant donné que les Comités nationaux de la CEI
intéressés sont représentés dans chaque comité d’études.
3) Les Publications de la CEI se présentent sous la forme de recommandations internationales et sont agréées
comme telles par les Comités nationaux de la CEI. Tous les efforts raisonnables sont entrepris afin que la CEI
s'assure de l'exactitude du contenu technique de ses publications; la CEI ne peut pas être tenue responsable de
l'éventuelle mauvaise utilisation ou interprétation qui en est faite par un quelconque utilisateur final.
4) Dans le but d'encourager l'uniformité internationale, les Comités nationaux de la CEI s'engagent, dans toute la
mesure possible, à appliquer de façon transparente les Publications de la CEI dans leurs publications
nationales et régionales. Toutes divergences entre toutes Publications de la CEI et toutes publications
nationales ou régionales correspondantes doivent être indiquées en termes clairs dans ces dernières.
5) La CEI n’a prévu aucune procédure de marquage valant indication d’approbation et n'engage pas sa
responsabilité pour les équipements déclarés conformes à une de ses Publications.
6) Tous les utilisateurs doivent s'assurer qu'ils sont en possession de la dernière édition de cette publication.
7) Aucune responsabilité ne doit être imputée à la CEI, à ses administrateurs, employés, auxiliaires ou
mandataires, y compris ses experts particuliers et les membres de ses comités d'études et des Comités
nationaux de la CEI, pour tout préjudice causé en cas de dommages corporels et matériels, ou de tout autre
dommage de quelque nature que ce soit, directe ou indirecte, ou pour supporter les coûts (y compris les frais
de justice) et les dépenses découlant de la publication ou de l'utilisation de cette Publication de la CEI ou de
toute autre Publication de la CEI, ou au crédit qui lui est accordé.
8) L'attention est attirée sur les références normatives citées dans cette publication. L'utilisation de publications
référencées est obligatoire pour une application correcte de la présente publication.
9) L’attention est attirée sur le fait que certains des éléments de la présente Publication de la CEI peuvent faire
l’objet de droits de propriété intellectuelle ou de droits analogues. La CEI ne saurait être tenue pour
responsable de ne pas avoir identifié de tels droits de propriété et de ne pas avoir signalé leur existence.
La présente norme internationale CEI 60730-2-12 a été préparée par le comité d'études 72 de
la CEI: Commandes automatiques pour appareils domestiques.
Cette deuxième édition annule et remplace la première édition publiée en 1993 et son
amendement 1 (1995). Cette deuxième édition constitue une révision technique, qui introduit
un certain nombre d’amendements dans les exigences applicables aux dispositifs de
commande électroniques.
Le texte de la présente norme est issu des documents suivants:
FDIS Rapport de vote
72/672/FDIS 72/679/RVD
Le rapport de vote indiqué dans le tableau ci-dessus donne toute information sur le vote ayant
abouti à l'approbation de cette norme.
60730-2-12 IEC:2005 – 5 –
INTERNATIONAL ELECTROTECHNICAL COMMISSION
____________
AUTOMATIC ELECTRICAL CONTROLS
FOR HOUSEHOLD AND SIMILAR USE –
Part 2-12: Particular requirements for
electrically operated door locks
FOREWORD
1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of IEC is to promote
international co-operation on all questions concerning standardization in the electrical and electronic fields. To
this end and in addition to other activities, IEC publishes International Standards, Technical Specifications,
Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC
Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested
in the subject dealt with may participate in this preparatory work. International, governmental and non-
governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely
with the International Organization for Standardization (ISO) in accordance with conditions determined by
agreement between the two organizations.
2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international
consensus of opinion on the relevant subjects since each technical committee has representation from all
interested IEC National Committees.
3) IEC Publications have the form of recommendations for international use and are accepted by IEC National
Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC
Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any
misinterpretation by any end user.
4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications
transparently to the maximum extent possible in their national and regional publications. Any divergence
between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in
the latter.
5) IEC provides no marking procedure to indicate its approval and cannot be rendered responsible for any
equipment declared to be in conformity with an IEC Publication.
6) All users should ensure that they have the latest edition of this publication.
7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and
members of its technical committees and IEC National Committees for any personal injury, property damage or
other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and
expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC
Publications.
8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is
indispensable for the correct application of this publication.
9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of
patent rights. IEC shall not be held responsible for identifying any or all such patent rights.
International Standard IEC 60730-2-12 has been prepared by IEC technical committee 72:
Automatic controls for household use.
This second edition cancels and replaces the first edition published in 1993 and Amendment 1
(1995). This second edition constitutes a technical revision, which incorporates amended
requirements for electronic controls in Annex H
The text of this standard is based on the following documents:
FDIS Report on voting
72/672/FDIS 72/679/RVD
Full information on the voting for the approval of this standard can be found in the report on
voting indicated in the above table.
– 6 – 60730-2-12 CEI:2005
Cette publication a été établie en accord avec les Directives ISO/IEC, Partie 2.
La présente Partie 2-12 doit être utilisée conjointement avec la CEI 60730-1. Elle a été établie
sur la base de la troisième édition de cette norme (1999) et de son amendement 1 (2003). Les
éditions futures de la CEI 60730-1, ou ses amendements, pourront être pris en considération.
La présente Partie 2-12 complète ou modifie les articles correspondants de la CEI 60730-1 de
façon à la transformer en norme CEI: Règles particulières pour les serrures électriques de
portes.
Lorsque cette Partie 2-12 spécifie "addition", "modification" or "remplacement", l’exigence, la
modalité d'essai ou le commentaire correspondant de la Partie 1 doivent être adaptés en
conséquence.
Lorsque aucune modification n'est nécessaire, la présente Partie 2-12 indique que l'article ou
le paragraphe approprié est applicable.
La liste des autres parties de la série CEI 60730 se trouve sur le site internet de la CEI.
Afin d'obtenir une norme complètement internationale, il a été nécessaire d'examiner des
exigences différentes résultant de l'expérience acquise dans diverses parties du monde et de
reconnaître les différences nationales dans les réseaux d'alimentation électrique et les règles
d'installation.
Les notes «dans certains pays» concernant des pratiques nationales différentes sont contenues dans les
paragraphes suivants:
– 17.1.3.1
– 17.7
– 17.7.1
– 17.7.7
– 17.10
– 17.10.4
Dans la présente publication:
1) Les caractères d'imprimerie suivants sont utilisés:
– prescriptions proprement dites: caractères romains;
– modalités d'essais: caractères italiques;
– commentaires: petits caractères romains.
2) Les paragraphes ou figures complémentaires à celles de la Partie 1 sont numérotées à partir de 101.
Le comité a décidé que le contenu de cette publication ne sera pas modifié avant la date de
maintenance indiquée sur le site web de la CEI sous «http://webstore.iec.ch» dans les données
relatives à la publication recherchée. A cette date, la publication sera
• reconduite;
• supprimée;
• remplacée par une édition révisée, ou
• amendée.
60730-2-12 IEC:2005 – 7 –
This publication has been drafted in accordance with the ISO/IEC Directives, Part 2.
This Part 2-12 is intended to be used in conjunction with IEC 60730-1. It was established on
the basis of the third edition of that standard (1999) and its amendment 1 (2003).
Consideration may be given to future editions of, or amendments to, IEC 60730-1.
This Part 2-12 supplements or modifies the corresponding clauses in IEC 60730-1 so as to
convert that publication into the IEC standard: Particular requirements for electrically operated
door locks.
Where this Part 2-12 states "addition", "modification" or "replacement", the relevant
requirement, test specification or explanatory matter in Part 1 should be adapted accordingly.
Where no change is necessary, this Part 2-12 indicates that the relevant clause or subclause
applies.
The list of other parts of the IEC 60730 series can be found on the IEC website.
In the development of a fully international standard it has been necessary to take into
consideration the differing requirements resulting from practical experience in various parts of
the world and to recognize the variation in national electrical systems and wiring rules.
The "in some countries" notes regarding differing national practice are contained in the following subclauses:
– 17.1.3.1
– 17.7
– 17.7.1
– 17.7.7
– 17.10
– 17.10.4
In this publication:
1) The following print types are used:
– requirements proper: in roman type;
– test specifications: in italic type;
– explanatory matter: in smaller roman type.
2) Subclauses or figures which are additional to those in Part 1 are numbered starting from 101.
The committee has decided that the contents of this publication will remain unchanged until the
maintenance result date indicated on the IEC web site under "http://webstore.iec.ch" in the data
related to the specific publication. At this date, the publication will be
• reconfirmed;
• withdrawn;
• replaced by a revised edition, or
• amended.
– 8 – 60730-2-12 CEI:2005
DISPOSITIFS DE COMMANDE ÉLECTRIQUE AUTOMATIQUES
À USAGE DOMESTIQUE ET ANALOGUE –
Partie 2-12: Règles particulières pour
les serrures électriques de portes
1 Domaine d'application et références normatives
L'article de la Partie 1 est applicable avec les exceptions suivantes:
1.1 Remplacement:
De façon générale, la présente partie de la CEI 60730 s'applique aux serrures électriques de
portes prévues pour empêcher l'ouverture des portes de matériels électrodomestiques et
analogues.
1.1.1 Remplacement:
La présente norme s’applique à la sécurité intrinsèque, aux valeurs et aux séquences de
fonctionnement dans la mesure où elles interviennent dans la protection des matériels, ainsi
qu'aux essais des serrures de portes utilisées dans, ou en association avec des matériels à
usage domestique et analogue.
La présente norme s'applique également aux serrures de portes pour appareils d'utilisation du
domaine d'application de la CEI 60335-1.
Partout où il est utilisé dans la présente norme, le terme «matériel» signifie «matériel et équipement».
Dans la présente norme, le terme "porte" signifie "porte, capot ou couvercle". Le terme "serrure de porte" signifie
"serrure électrique de porte".
La présente norme ne s'applique pas aux serrures de portes conçues exclusivement pour des
usages industriels.
La présente norme est également applicable aux serrures de portes particulières utilisées
comme parties d'un système de commande ou aux serrures de portes mécaniquement
intégrées dans des dispositifs de commande multifonctions ayant des sorties non électriques.
Les serrures de portes pour matériels non prévus pour usage domestique normal, mais qui
peuvent néanmoins être utilisés par le public, comme le matériel prévu pour être utilisé par des
personnes inexpérimentées dans les magasins, dans l'industrie légère et dans les fermes,
entrent dans le domaine d'application de la présente norme.
Voir aussi l'Annexe J.
1.1.2 Remplacement:
La présente norme s'applique aux serrures de portes avec circuits électriques et circuits de
commande mis en œuvre, par exemple, par bilames, enroulements magnétiques, mémoires
métalliques, détecteurs de pression, dispositifs thermosensibles à expansion ou éléments
électroniques.
1.1.3 Ne s'applique pas.
60730-2-12 IEC:2005 – 9 –
AUTOMATIC ELECTRICAL CONTROLS
FOR HOUSEHOLD AND SIMILAR USE –
Part 2-12: Particular requirements for
electrically operated door locks
1 Scope and normative references
This clause of Part 1 is applicable except as follows:
1.1 Replacement:
In general, this part of IEC 60730 applies to electrically operated door locks intended to prevent
the opening of doors in equipment for household and similar use.
1.1.1 Replacement:
This standard applies to the inherent safety, to the operating values, operating sequences
where such are associated with equipment protection, and to the testing of door locks used in,
or in association with, household and similar equipment.
This standard is also applicable to door locks for appliances within the scope of IEC 60335-1.
Throughout this standard, the word “equipment” means “appliance” and “equipment”.
Throughout this standard, the word “door” means “door, cover or lid”. The words “door lock” mean “electrically
operated door lock”.
This standard does not apply to door locks designed exclusively for industrial applications.
This standard is also applicable to individual door locks utilized as part of a control system or
door locks which are mechanically integral with multi-functional controls having non-electrical
outputs.
Door locks for equipment not intended for normal household use, but which nevertheless may
be used by the public, such as equipment intended to be used by laymen in shops, in light
industry and on farms, are within the scope of this standard.
See also Annex J.
1.1.2 Replacement:
This standard applies to door locks with electrical circuits and control circuits which are,
for example, operated by bimetals, magnet coils, memory metals, pressure elements,
temperature-sensitive expansion elements or electronic elements.
1.1.3 Not applicable.
– 10 – 60730-2-12 CEI:2005
1.1.4 Remplacement:
La présente norme s'applique aux dispositifs de commande manuels dans la mesure où ils font
partie intégrante, électriquement et/ou mécaniquement, des serrures de portes.
Les exigences pour les interrupteurs manuels ne faisant pas partie d’une serrure de porte sont contenues dans la
CEI 61058-1.
1.3 Remplacement:
La présente norme ne prend pas en considération la valeur de réponse d'une action
automatique d'une serrure de porte lorsqu'elle est influencée par la méthode de montage de la
serrure de porte dans l'équipement. Dans le cas où une telle valeur de réponse est importante
du point de vue de la protection de l'utilisateur ou de l'environnement, la valeur spécifiée dans
la norme particulière de l'équipement domestique approprié ou prescrite par le fabricant doit
s'appliquer.
1.4 Remplacement:
La présente norme s'applique également aux serrures de portes incorporant des dispositifs
électroniques, pour lesquels les exigences sont données dans l'Annexe H.
La présente norme s'applique également aux serrures de portes utilisant des thermistances
CTN et CTP, pour lesquelles les exigences sont contenues dans l'Annexe J.
2 Définitions
L'article de la Partie 1 est applicable avec les exceptions suivantes:
2.2 Définitions des différents types de dispositifs de commande en fonction de
l’utilisation
Définition complémentaire:
2.2.101
serrure électrique de porte
mécanisme intégré ou incorporé fonctionnant électriquement, prévu pour commander la
fermeture de portes d’appareils domestiques et analogues au moyen d’un dispositif de sortie
mécanique qui physiquement ferme une porte, une plaque ou un couvercle.
2.3 Définitions concernant les fonctions des dispositifs de commande
Définitions complémentaires:
2.3.101
valeur de mise au repos
valeur de fonctionnement pour laquelle le moyen de fermeture se dégage
2.3.102
fermeture
action mécanique prévue pour bloquer un mécanisme de porte de façon qu’une ouverture de
porte ne soit pas possible dans des conditions définies
2.3.103
délai de fermeture
intervalle de temps s’écoulant entre le signal de fermeture et l’achèvement de l’action de
fermeture
60730-2-12 IEC:2005 – 11 –
1.1.4 Replacement:
This standard also applies to manual controls when such are electrically and/or mechanically
integral with door locks.
Requirements for manual switches not forming part of a door lock are contained in IEC 61058-1.
1.3 Replacement:
This standard does not take into account the response value of an automatic action of a door
lock, if such a response value is dependent upon the method of mounting the door lock in the
equipment. Where a response value is of significant purpose for the protection of the user, or
surroundings, the value defined in the appropriate household equipment standard or as
determined by manufacturer shall apply.
1.4 Replacement:
This standard also applies to door locks incorporating electronic devices, requirements for
which are contained in Annex H.
This standard also applies to door locks using NTC and PTC thermistors, requirements for
which are contained in Annex J.
2 Definitions
This clause of Part 1 is applicable except as follows:
2.2 Definitions of types of control according to purpose
Additional definition:
2.2.101
electrically operated door lock
incorporated or integrated electrically operated mechanism intended to control the door locking
in household and similar equipment by means of a mechanical output mechanism which
physically secures a door, cover or lid.
2.3 Definitions relating to the function of controls
Additional definitions:
2.3.101
drop-out value
operating value at which the locking means is disengaged.
2.3.102
locking
mechanical action intended to block a door mechanism in such a way that opening of the door
is prevented under defined conditions.
2.3.103
locking delay
period of time elapsing between the signal to lock and completion of the locking action.
– 12 – 60730-2-12 CEI:2005
2.3.104
force de fermeture
force mécanique minimale prévue pour que la serrure empêche l’ouverture de la porte
2.3.105
sécurité de fermeture
condition selon laquelle la serrure empêche une porte d’appareil de s’ouvrir ou empêche la
mise en fonction de l’appareil, même si la serrure de porte est endommagée
2.3.106
délai de déverrouillage
intervalle de temps s’écoulant entre le signal de déverrouillage et l’achèvement de l’action de
déverrouillage
3 Exigences générales
L'article de la Partie 1 est applicable.
4 Généralités sur les essais
L'article de la Partie 1 est applicable avec les exceptions suivantes:
4.1 Conditions d'essai
4.1.1 Addition:
Une porte véritable ou un dispositif adapté pour simuler une porte peuvent être utilisés pour les essais de la
présente norme.
5 Caractéristiques nominales
L'article de la Partie 1 est applicable.
6 Classification
L'article de la Partie 1 est applicable avec les exceptions suivantes:
6.3 Selon les fonctions
Paragraphes complémentaires:
6.3.101 – serrures de portes;
6.3.101.1 – à détection de tension;
Le modèle peut comporter un élément chauffant, un enroulement magnétique ou un élément électrique détecteur de
tension.
6.3.101.2 – à détection de courant;
Le modèle peut comporter un élément chauffant, un enroulement magnétique ou un élément électrique détecteur de
courant.
60730-2-12 IEC:2005 – 13 –
2.3.104
locking force
minimum mechanical force intended for the door lock to prevent opening of the door.
2.3.105
locking security
condition in which the door lock either prevents an appliance door from being opened or
prevents the appliance from being operated, even if the door lock is damaged.
2.3.106
unlocking delay
period of time elapsing between the signal to unlock and completion of the unlocking action.
3 General requirements
This clause of Part 1 is applicable.
4 General notes on tests
This clause of Part 1 is applicable except as follows:
4.1 Conditions of test
4.1.1 Addition:
An actual door or a suitable device simulating the door may be used for the tests of this standard.
5 Rating
This clause of Part 1 is applicable.
6 Classification
This clause of Part 1 is applicable except as follows:
6.3 According to their purpose
Additional subclauses:
6.3.101 – door locks;
6.3.101.1 – voltage sensing;
The design may include a voltage-sensitive heating element, a magnet coil or an electronic element.
6.3.101.2 – current sensing;
The design may include a current-sensitive heating element, a magnet coil or an electronic element.
– 14 – 60730-2-12 CEI:2005
6.3.101.3 – actionnées thermiquement ;
La fermeture peut être commandée soit directement soit indirectement par un élément thermosensible.
6.3.101.4 – actionnées par la pression.
Le verrouillage peut être commandé soit directement soit indirectement par des éléments sensibles à la pression.
6.4 Selon les caractéristiques du fonctionnement automatique
Paragraphe complémentaire:
6.4.101 - sécurité de fermeture (Type 1.AA ou 2.AA)
7 Informations
L'article de la Partie 1 est applicable avec les exceptions suivantes:
Tableau 7.2
Addition:
Article ou
Informations Méthode
paragraphe
Points complémentaires:
101)
101 Délai de fermeture 2.3.103 X
101)
102 Délai de déverrouillage 2.3.106 X
101)
103 Force de fermeture (si déclarée) 2.3.104 X
18.101.1
104 Valeur de mise au repos 2.3.101 X
102)
105 Effets sur les sorties commandées (si déclarés) 6.4.101 X
18.101.2
106 Procédure pour l'essai de l'Article 17 17 X
Addition à la Note 4 :
Pour les serrures de portes, les limites des grandeurs de manœuvre sont spécifiées soit dans la Partie 2 de
l'appareil électrodomestique applicable, soit par le fabricant de l'appareil, ou bien elles sont en conformité avec
ce qui est déclaré par le fabricant de serrures de portes (voir 17.7 et 17.8).
Notes complémentaires:
101)
Ces informations sont spécifiées dans la Partie 2 appropriée de l’appareil électrodomestique, par le fabricant
d’appareils ou par le fabricant de serrures de portes.
102)
Ceci implique la déclaration par le fabricant des conséquences d’une défaillance de la serrure de porte.
8 Protection contre les chocs électriques
L'article de la Partie 1 est applicable.
9 Dispositions en vue de la mise à la terre de protection
L'article de la Partie 1 est applicable.
60730-2-12 IEC:2005 – 15 –
6.3.101.3 – thermally operated;
Locking may be controlled either directly or indirectly by a temperature-sensitive element.
6.3.101.4 – pressure operated.
Latching may either be directly or indirectly controlled by pressure-sensitive elements.
6.4 According to features of automatic action
Additional subclause:
6.4.101 – locking security (Type 1.AA or 2.AA).
7 Information
This clause of Part 1 is applicable except as follows:
Table 7.2
Addition:
Clause
Information or Method
subclause
Additional items:
101)
101 Locking delay 2.3.103 X
101)
102 Unlocking delay 2.3.106 X
101)
103 Locking force (if declared) 2.3.104 X
18.101.1
104 Drop-out value 2.3.101 X
102)
105 Effects on controlled outputs (if declared) 6.4.101 X
18.101.2
106 Method of operation for the test of Clause 17 17 X
Addition to Note 4:
For door locks, limits of activating quantity are specified either in the applicable household appliance standard, by
the appliance manufacturer or as declared by the door lock manufacturer (see 17.7 and 17.8).
Additional notes:
101)
These are specified either in the applicable household appliance part 2, by the appliance manufacturer or by
the door lock manufacturer.
102)
This provides for manufacturer declaration of the outputs which will result after failure of the door lock.
8 Protection against electric shock
This clause of Part 1 is applicable.
9 Provision for protective earthing
This clause of Part 1 is applicable.
– 16 – 60730-2-12 CEI:2005
10 Bornes et connexions
L'article de la Partie 1 est applicable.
11 Exigences de construction
L'article de la Partie 1 est applicable.
12 Résistance à l'humidité et à la poussière
L'article de la Partie 1 est applicable.
13 Résistance d'isolement et rigidité diélectrique
L'article de la Partie 1 est applicable.
14 Echauffements
L'article de la Partie 1 est applicable.
15 Tolérances de fabrication et dérive
L'article de la Partie 1 est applicable.
16 Contraintes climatiques
L'article de la Partie 1 est applicable.
17 Endurance
L'article de la Partie 1 est applicable avec les exceptions suivantes:
17.1.3 Séquence et conditions d'essais
Remplacement:
17.1.3.1 En général, la séquence d'essais est la suivante:
– un essai de vieillissement selon 17.6 (cet essai ne s'applique qu'aux actions de Type 1.M
ou 2.M);
– un essai de surtension d’action automatique accélérée spécifié en 17.7 (au Canada, en
Chine et aux USA, cet essai est remplacé par un essai de surcharge);
– un essai d'action automatique accélérée spécifié en 17.8;
– un essai de surtension d’action manuelle accélérée spécifié en 17.10 (au Canada, en Chine
et aux USA, cet essai est remplacé par un essai de surcharge);
– un essai d'action manuelle spécifié en 17.11.
60730-2-12 IEC:2005 – 17 –
10 Terminals and terminations
This clause of Part 1 is applicable.
11 Constructional requirements
This clause of Part 1 is applicable.
12 Moisture and dust resistance
This clause of Part 1 is applicable.
13 Electric strength and insulation resistance
This clause of Part 1 is applicable.
14 Heating
This clause of Part 1 is applicable.
15 Manufacturing deviation and drift
This clause of Part 1 is applicable.
16 Environmental stress
This clause of Part 1 is applicable.
17 Endurance
This clause of Part 1 is applicable except as follows:
17.1.3 Test sequence and conditions
Replacement:
17.1.3.1 In general, the sequence of tests is:
– an ageing test specified in 17.6 (this test applies only to those actions classified as Type
1.M or 2.M);
– an over-voltage test of automatic action at accelerated rate specified in 17.7 (in Canada,
China and the USA this test is replaced by the overload test);
– a test of automatic action at acceleration rate specified in 17.8;
– an over-voltage test of manual action at accelerated speed specified in 17.10 (in Canada,
China and the USA this test is replaced by an overload test);
– a test of manual action as specified in 17.11.
– 18 – 60730-2-12 CEI:2005
17.3 Conditions thermiques pour les essais
Remplacement:
17.3.1 Les conditions thermiques suivantes s’appliquent aux serrures de portes:
– les parties qui sont accessibles lorsque la serrure de porte est montée selon les
instructions déclarées du fabricant doivent être exposées à la température ambiante
normale;
– la surface de montage de la serrure de porte doit être maintenue entre T et
s max
T +5 °C ou 1,05 fois T , selon la valeur la plus élevée;
s max s max
– si le dispositif de commande n’est pas cyclé avec une température de surface de montage
de T , l’essai est alors conduit à (20 ± 5) °C.
s max
17.3.2 Ne s'applique pas.
17.4 Conditions manuelles et mécaniques des essais
17.4.1 Remplacement:
L’action manuelle doit simuler le fonc
...








Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.
Loading comments...