Abstract

ISO 8434-2:2007 specifies general and dimensional requirements for the design and performance of 37° flared connectors that are suitable for use with ferrous and non-ferrous tubes with outside diameters from 6 mm to 50,8 mm, inclusive. These connectors are for use in fluid power and general applications within the limits of pressure and temperature specified. They are intended for the connection of tubes and hose fittings to ports in accordance with ISO 6149‑1, ISO 1179‑1, ISO 9974‑1 and ISO 11926‑1. (See ISO 12151‑5 for related hose fitting specification.) ISO 8434-2:2007 also specifies a performance and qualification test for 37° flared connectors.

Status
Not Published
Current Stage
6000 - International Standard under publication - 60 Publication
Start Date
06-Nov-2026

Buy Documents

Draft

ISO/FDIS 8434-2 - Metallic tube connections for fluid power and general use — Part 2: 37 degree flared connectors

Release Date:27-Aug-2026
English language (54 pages)
sale 15% off
sale 15% off
Draft

REDLINE ISO/FDIS 8434-2 - Metallic tube connections for fluid power and general use — Part 2: 37 degree flared connectors

Release Date:27-Aug-2026
English language (54 pages)
sale 15% off
sale 15% off
Draft

ISO/FDIS 8434-2 - Raccordements de tubes métalliques pour transmissions hydrauliques et pneumatiques et applications générales — Partie 2: Connecteurs évasés à 37 degrés

Release Date:29-Sep-2026
French language (58 pages)
sale 15% off
sale 15% off

ISO 8434-2 is an ISO standard for metallic tube connections used in fluid power and general applications. It specifies the design, dimensions, materials, pressure and temperature limits, designation system, and qualification testing for 37° flared connectors.

These connectors are intended for ferrous and non-ferrous tubes and for connection to ports in the ISO 6149-1, ISO 1179-1, ISO 9974-1 and ISO 11926-1 families. The document also covers performance and qualification tests so users can verify that a connector design will hold pressure, resist overtightening, and survive repeated assembly.

What does ISO 8434-2 specify?

ISO 8434-2 specifies general and dimensional requirements for 37° flared connectors for use with tubes with outside diameters from 4 mm to 50.8 mm inclusive. It applies to fluid power and general use, and it focuses on full-flow connections with metal-to-metal sealing.

The document is organized into clauses on scope, normative references, terms and definitions, materials, pressure and temperature requirements, designation, tube requirements, dimensions, design, screw threads, manufacture, assembly instructions, procurement information, marking, performance and qualification testing, and identification statement. Annex A is normative and covers reducing connectors.

AnnexWhat it covers
Annex ALength reduction factors for reducing connectors, also called jump connectors

What are the key requirements of ISO 8434-2?

Materials and service conditions

ISO 8434-2 requires connector bodies to be made from carbon steel or stainless steel, with nuts and sleeves matched to the body material unless otherwise specified. The working pressure is the lower of the connector connection rating and the rating of the relevant stud end, so the assembled joint is limited by the weakest rated end.

For carbon steel connectors, Clause 5 sets the temperature range for petroleum-base hydraulic fluids, while stainless steel connectors have their own temperature range. If an application falls outside the pressure or temperature limits, the manufacturer is to be consulted.

The table in Clause 5 links tube outside diameter, maximum tube wall thickness for flaring, and maximum working pressure. In practice, this is the first check a designer or buyer should make when selecting a size, because the tube wall must be flareable and the pressure rating must suit the circuit.

Dimensions, threads, and design rules

Clause 6 defines an ordering designation built from the word “Connector,” the standard number, the connector style letters, the tube size, and where relevant the stud-end thread and material symbol. This matters in purchasing and documentation because it gives one format for ordering and identification.

Clause 8 and Clause 9 control the geometry of the connector. The document sets across-flats dimensions, angular tolerances, passage offsets, wall thickness expectations, and rules for the contours of elbows, tees, crosses, and reducing connectors. These limits matter because they affect wrench access, flow resistance, strength, and whether the parts can be assembled without distortion.

Clause 9 also states that stud ends for new hydraulic fluid power designs shall be in accordance with ISO 6149-3, and that stud ends in accordance with ISO 1179-3, ISO 9974-2 and ISO 11926-3 shall not be used for new designs in hydraulic fluid power applications. For engineering teams, this is a design choice that affects compatibility with modern port systems.

Tube compatibility and preparation

Clause 7 says the connectors shall suit the tube sizes given in the metric and inch tube tables. It also requires tubes to be free of scratches, damage, and imperfections that could impair function.

For carbon steel tubes, the document requires seamless, cold-drawn, normalized tubing and gives mechanical property limits and inspection documentation expectations. For stainless steel tubes, it points to ISO 1127 and sets requirements for cold drawing, solution annealing, surface condition, mechanical properties, hardness, and inspection records. In practice, this tells the supplier what tubing evidence must accompany the parts.

Metric tubing is preferred for new and future designs, even though inch tubing is also covered. That matters for procurement and standardization because the connector family supports both tube systems.

Manufacture, corrosion protection, and marking

Clause 11 requires good workmanship, clean surfaces, and protection against burrs, loose scale, slivers, and other defects that could affect function. It also sets a surface texture requirement for machined surfaces and requires carbon steel external surfaces and threads to pass salt spray testing in accordance with ISO 9227.

The corrosion protection clause also prohibits cadmium plating and hexavalent chromate coatings. Internal fluid passages must be protected during storage and shipment, and any change in plating or coating must be re-qualified to confirm that assembly torque is not affected.

Clause 14 requires connector bodies and nuts to be permanently marked with the manufacturer’s name, trademark, or code identifier unless otherwise agreed. Nuts for connectors used with 30 mm and 32 mm tubes must also be marked with the tube outside diameter. This helps traceability and reduces mix-ups during assembly and maintenance.

Performance and qualification testing

Clause 15 ties the document to ISO 19879 test methods and requires proof, burst, cyclic endurance, overtightening, and repeated assembly testing. The connector, swivel nut, and sleeve are tested in as-shipped condition, which means coatings or rust preventatives remain part of the tested condition.

The proof test, burst test, and cyclic endurance test are linked to size-specific pressure values in the table in Clause 15. The document also gives qualification torque values. In practice, that means designers, labs, and suppliers must test not only strength and leakage, but also how the joint behaves when tightened, over-tightened, and reused.

What terms does ISO 8434-2 define?

  • Adjustable stud end - A stud end that allows final orientation by tightening the locknut, which is used on shaped connectors such as tees, crosses, and elbows.
  • Non-adjustable stud end - A stud end used on straight connectors that does not need a specific orientation before final tightening.
  • Run - The two main axially aligned outlets of a tee or cross connector.
  • Branch - The side outlet or outlets of a tee or cross connector.
  • Chamfer - A conical removal at the start of a thread to help assembly and prevent thread damage.
  • Assembly torque - The torque needed to achieve a satisfactory final connection.
  • Qualification test torque - The torque used to check whether the connector meets the document’s requirements.
  • Overtightening - The torque a nut can withstand without deformation that makes it unusable.

Who uses ISO 8434-2?

ISO 8434-2 is used by designers, manufacturers, suppliers, test laboratories, and buyers of fluid power components. It is relevant to hydraulic and pneumatic equipment, general fluid conveyance, and tube-to-port or tube-to-hose-fittings connection work.

In practice, engineers use it to choose sizes, thread types, and port interfaces; manufacturers use it to design and qualify parts; buyers use it to specify the connector family and service limits; and quality teams use it to verify test evidence, marking, and material documentation.

What changed in ISO 8434-2 from the previous edition?

ISO 8434-2:2026 is the third edition and it cancels and replaces ISO 8434-2:2007. The foreword says the document was technically revised.

The stated changes include:

  • the scope was updated to include tube outside diameters from 4 mm to 50.8 mm, with sizes 4, 5, and 22 mm added where applicable
  • the normative references and terms and definitions were updated, including Figure 1
  • references to connector bodies made from copper alloys were removed
  • pressure derating for stainless steel connectors was removed
  • material and letter designations were added in Clause 6
  • Clause 7 was rewritten and references to ISO 3304 and ISO 3305 were removed
  • wall thickness requirements were added in Clause 9
  • screw threads, corrosion protection, assembly instructions, procurement information, performance requirements, and the identification statement were rewritten
  • a repeated assembly test was added
  • figures were renumbered and redrawn, and some new figure and table content was added for chamfers and optional dual angle seat design
  • Annex A was updated, including a change to one reduction factor
  • the bibliography was updated

Which standards are used with ISO 8434-2?

ISO 8434-2 names several companion standards and references that support design, testing, and matching parts:

  • ISO 725 - gives the basic dimensions for the inch screw threads used on 37° flared ends
  • ISO 1127 - gives dimensions and tolerances for stainless steel tubes
  • ISO 1179-3, ISO 6149-3, ISO 9974-2, and ISO 11926-3 - provide compatible stud-end dimensions and sealing details
  • ISO 4759-1 - provides fastener tolerance grades used for hex dimensions
  • ISO 5598 - gives fluid power vocabulary used for definitions
  • ISO 9227 - gives the salt spray test used for corrosion protection
  • ISO 19879 - gives the test methods used for proof, burst, cyclic endurance, and related qualification testing
  • ISO 21920-1 - provides surface texture notation used for machined surfaces
  • ISO 12151-5 - gives the related hose fitting specification for hose fittings with ISO 8434-2 37° flared ends
  • ISO 6149-1, ISO 1179-1, ISO 9974-1, and ISO 11926-1 - identify the port systems the connectors are intended to mate with

What does the ISO 8434-2 document contain?

ISO 8434-2 contains dimensional tables for connector types, tube sizes, nuts, sleeves, union connectors, stud connectors, bulkhead connectors, swivel connectors, caps, and plugs. It also includes figures showing the connector forms and the way the flare, nut, sleeve, and stud end fit together.

The document gives test pressures, qualification torque values, and test sequences for proof, burst, cyclic endurance, overtightening, and repeated assembly. Those tables and procedures are used for design validation and product qualification.

Annex A contains calculation factors and associated figures for reducing connectors, including jump-size configurations. That annex is used when one end of the connector is a different size from the other and the overall length has to be adjusted accordingly.

Relations

Effective Date
16-Dec-2023

Buy Documents

Draft

ISO/FDIS 8434-2 - Metallic tube connections for fluid power and general use — Part 2: 37 degree flared connectors

Release Date:27-Aug-2026
English language (54 pages)
sale 15% off
sale 15% off
Draft

REDLINE ISO/FDIS 8434-2 - Metallic tube connections for fluid power and general use — Part 2: 37 degree flared connectors

Release Date:27-Aug-2026
English language (54 pages)
sale 15% off
sale 15% off
Draft

ISO/FDIS 8434-2 - Raccordements de tubes métalliques pour transmissions hydrauliques et pneumatiques et applications générales — Partie 2: Connecteurs évasés à 37 degrés

Release Date:29-Sep-2026
French language (58 pages)
sale 15% off
sale 15% off

Get Certified

Connect with accredited certification bodies for this standard

Institut za varilstvo d.o.o. (Welding Institute)

Slovenia's leading welding institute since 1952. ISO 3834, EN 1090, pressure equipment certification, NDT personnel, welder qualification. Only IIW Au

SA Slovenia Verified

Sponsored listings

Frequently Asked Questions

ISO 8434-2 is a draft published by the International Organization for Standardization (ISO). Its full title is "Metallic tube connections for fluid power and general use — Part 2: 37 degree flared connectors". This standard covers: ISO 8434-2:2007 specifies general and dimensional requirements for the design and performance of 37° flared connectors that are suitable for use with ferrous and non-ferrous tubes with outside diameters from 6 mm to 50,8 mm, inclusive. These connectors are for use in fluid power and general applications within the limits of pressure and temperature specified. They are intended for the connection of tubes and hose fittings to ports in accordance with ISO 6149‑1, ISO 1179‑1, ISO 9974‑1 and ISO 11926‑1. (See ISO 12151‑5 for related hose fitting specification.) ISO 8434-2:2007 also specifies a performance and qualification test for 37° flared connectors.

ISO 8434-2:2007 specifies general and dimensional requirements for the design and performance of 37° flared connectors that are suitable for use with ferrous and non-ferrous tubes with outside diameters from 6 mm to 50,8 mm, inclusive. These connectors are for use in fluid power and general applications within the limits of pressure and temperature specified. They are intended for the connection of tubes and hose fittings to ports in accordance with ISO 6149‑1, ISO 1179‑1, ISO 9974‑1 and ISO 11926‑1. (See ISO 12151‑5 for related hose fitting specification.) ISO 8434-2:2007 also specifies a performance and qualification test for 37° flared connectors.

ISO 8434-2 is classified under the following ICS (International Classification for Standards) categories: 23.100.40 - Piping and couplings. The ICS classification helps identify the subject area and facilitates finding related standards.

ISO 8434-2 has the following relationships with other standards: It is inter standard links to ISO 8434-2:2007. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.

ISO 8434-2 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.

Standards Content (Sample)

Contents

  • Introduction
  • 1 Scope
  • 2 Normative references
  • 3 Terms and definitions
  • 3.1 adjustable stud end
  • 3.2 non-adjustable stud end
  • 3.3 run
  • 3.4 branch
  • 3.5 chamfer
  • 3.6 assembly torque
  • 3.7 qualification test torque
  • 3.8 overtightening
  • 3.9 jump size connector
  • 4 Materials
  • 4.1 General
  • 5 O-ring
  • 4.2 Connector bodies
  • 4.3 Nuts
  • 4.4 Sleeves
  • 5 Pressure and temperature requirements
  • 5.6 The pressure and temperature requirements given in Table 1 and in 5.2 and 5.3 are for tube
  • 5.7 To achieve these maximum working pressures with a 4:1 design factor, the maximum tube wall
  • 6 Designation of connectors
  • 7 Requirements for tubes
  • 7.2 Carbon steel tubes
  • 7.3 Stainless steel tubes
  • 8 Across flats dimensions and tolerances
  • 9 Design
  • 9.1 Connectors
  • 9.2 Dimensions
  • 9.3 Passage tolerances
  • 9.4 Wall thickness
  • 9.5 Angular tolerances
  • 9.6 Contour details
  • 9.7 Stud ends
  • 9.8 Reducing connectors
  • 10 Screw threads
  • 10.2 Stud ends (connection ends)
  • 11 Manufacture
  • 11.1 Construction
  • 11.2 Workmanship
  • 11.3 Corrosion protection
  • 11.4 Connector protection
  • 11.5 Corners
  • 12 Assembly instructions
  • 13 Procurement information
  • 14 Marking of components
  • 15 Performance and qualification test
  • 15.1 Performance requirements
  • 16 Identification statement
  • 4 × 4 4 5/16-24 UNF 1,6 29,7 19,6 5,6 11 12 -
  • 5 × 5 5 3/8-24 UNF 3,2 31,2 21,1 5,6 11 12 -
  • Annex A
  • Bibliography

Introduction

In fluid power systems, power is transmitted and controlled through a fluid (liquid or gas) under pressure within an enclosed circuit. In general applications, a fluid may be conveyed under pressure. Components may be connected through their ports by connections (connectors), tubes and hoses. Tubes are rigid conductors; hoses are flexible conductors.

[1] [2] This document is based on the US standard SAE J514-1 and SAE J533 . The threads for the 37° flared connection are unified inch threads in accordance with ISO 725. The inch threads were not changed to metric threads according to ISO 261 to allow connectors complying with this document to be used in existing applications without requiring a change to tube or hose assemblies. Also, the thread-to-nut overtightening and seal performance have been extensively tested; to change to metric threads would require an extensive test program at considerable cost without providing any functional improvement. The threads are integral to themselves, connectors of this type match only to themselves and, other than having metric threads, no value in changing could be found. Major international companies that have used these connectors have adopted the design without noting any problems. All wrench flats specified in this document are dimensioned to be used with ISO standard metric wrenches.

FINAL DRAFT International Standard ISO/FDIS 8434-2:2026(en) Metallic tube connections for fluid power and general use — Part 2:

37 degree flared connectors

1 Scope

This document specifies the general and dimensional requirements for the design and performance of 37° flared connectors that are suitable for use with ferrous and non-ferrous tubes with outside diameters from 4 mm to 50,8 mm, inclusive. These connectors provide full-flow connections with metal-to-metal sealings. These connectors are for use in fluid power and general applications within the limits of pressure and temperature specified in this document.

They are intended for the connection of tubes and hose fittings to ports in accordance with ISO 6149-1, ISO 1179-1, ISO 9974-1 and ISO 11926-1. (See ISO 12151-5 for related hose fitting specification.) NOTE 1 For new designs in hydraulic fluid power applications, see the requirements given in 9.7. Where the requirements of the application allow for the use of elastomeric seals, connector designs that conform to International Standards and incorporate elastomeric sealing are preferred.

NOTE 2 For use under conditions outside the limits for pressure or temperature, or both, see 5.4. Both metric and inch tubing can be accommodated by changing the sleeve (see Figure 9). In the past, these connectors have been used predominantly with inch tubing. For new and future designs, the use of metric tubing is preferred.

This document also specifies performance and qualification tests for 37° flared connectors.

2 Normative references

The following documents are referred to in the text in such a way that some or all of their content constitutes requirements of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. ISO 725, ISO inch screw threads — Basic dimensions ISO 1127, Stainless steel tubes — Dimensions, tolerances and conventional masses per unit length ISO 1179-3, Connections for general use and fluid power — Ports and stud ends with ISO 228-1 threads with elastomeric or metal-to-metal sealing — Part 3: Light-duty (L series) stud ends with sealing by O-ring with retaining ring (types G and H) ISO 4759-1, Tolerances for fasteners — Part 1: Bolts, screws, studs and nuts — Product grades A, B and C ISO 5598, Fluid power systems and components — Vocabulary ISO 6149-3, Connections for hydraulic fluid power and general use — Ports and stud ends with ISO 261 metric threads and O-ring sealing — Part 3: Dimensions, design, test methods and requirements for light-duty (L series) stud ends ISO 9227, Corrosion tests in artificial atmospheres — Salt spray tests ISO 9974-2, Connections for general use and fluid power — Ports and stud ends with ISO 261 threads with elastomeric or metal-to-metal sealing — Part 2: Stud ends with elastomeric sealing (type E)

ISO/FDIS 8434-2:2026(en) ISO 11926-3, Connections for general use and fluid power — Ports and stud ends with ISO 725 threads and O-ring sealing — Part 3: Light-duty (L series) stud ends ISO 19879, Metallic tube connections for fluid power and general use — Test methods for hydraulic fluid power connections ISO 21920-1, Geometrical product specifications (GPS) — Surface texture: Profile — Part 1: Indication of surface texture

3 Terms and definitions

For the purposes of this document, the terms and definitions given in ISO 5598 and the following apply. ISO and IEC maintain terminology databases for use in standardization at the following addresses:

  • ISO Online browsing platform: available at https:// www .iso .org/ obp
  • IEC Electropedia: available at https:// www .electropedia .org/

3.1 adjustable stud end

stud end connector that allows for connector orientation through final tightening of the locknut to complete the connection Note 1 to entry: This type of stud end is typically used on shaped connectors (e.g. tees, crosses and elbows).

3.2 non-adjustable stud end

stud end connector that does not require specific orientation before final tightening of the connection because it is only used on straight connectors

3.3 run

two principal, axially aligned outlets of a tee connector or cross connector Key 1 run 2 branch Figure 1 — Run and branch illustration

3.4 branch

side outlet(s) of a tee connector or cross connector

3.5 chamfer

removal of a conical portion at the entrance of a thread to assist assembly and prevent damage to the start of the thread

3.6 assembly torque

torque required to achieve a satisfactory final connection

ISO/FDIS 8434-2:2026(en)

3.7 qualification test torque

torque used to verify conformity of the connector to the requirements of this document

3.8 overtightening

torque that the nut withstands without deformation that renders it unusable

3.9 jump size connector

connector with dis-similar end connections, for example, –6 male flare with a –12 stud end

4 Materials

4.1 General

Figure 2 shows the cross-section and components of a typical 37° flared connector. Key 1 straight stud connector body 2 tube nut 3 tube 4 sleeve

5 O-ring

a Stud end in accordance with ISO 1179-3, ISO 6149-3, ISO 9974-2 or ISO 11926-3. Figure 2 — Cross-section of typical 37° flared connection

4.2 Connector bodies

Bodies shall be manufactured from carbon steel or stainless steel, which will provide the minimum requirements for the pressure and temperature ratings specified in Clause 5 when tested in accordance with Clause 15. They shall have characteristics that make them suitable for use with the fluid to be conveyed and to provide an effective joint.

4.3 Nuts

Nuts to be used with carbon steel bodies shall be made of carbon steel and those for use with stainless steel bodies shall be made of stainless steel unless otherwise specified.

ISO/FDIS 8434-2:2026(en)

4.4 Sleeves

Sleeves shall be manufactured from a material similar to the bodies.

5 Pressure and temperature requirements

5.1 The working pressure of the connector shall be the lower of the working pressure of the 37° flared connector connection given in Table 1 and the working pressure of the respective stud end. 5.2 Flared connectors in accordance with this document made of carbon steel shall meet or exceed without leakage the requirements to the working pressures given in Table 1 when used at temperatures from −40 °C to +120 °C with petroleum base hydraulic fluids.

5.3 Connectors made of stainless steel complying with this document shall be suitable for use at the working pressures given in Table 1 when used at temperatures from −60 °C to +50 °C. 5.4 For applications under conditions outside the limits for pressure or temperature, or both given in Table 1 and in 5.2 and 5.3, the manufacturer shall be consulted. 5.5 Connectors conforming to this document shall be tested in accordance with Clause 15 to ensure that they meet or exceed the pressure requirements given in Table 1.

5.6 The pressure and temperature requirements given in Table 1 and in 5.2 and 5.3 are for tube

connections and connector bodies only. For port and stud end pressure and temperature ratings, the values in the respective port and stud end standards shall apply.

5.7 To achieve these maximum working pressures with a 4:1 design factor, the maximum tube wall

thicknesses shown in Table 1 are sufficient. See ISO 10763 to confirm the necessary tube wall thickness for a specific working pressure.

Table 1 — Working pressures for 37° flared connections Maximum wall thickness of b Tube outside diameter (OD) Maximum working pressure a tube for flaring Metric Inch Metric tube Inch tube Carbon steel and stainless steel

mm in mm mm MPa (bar) 4 1/8 1 0,89 35 (350) 5 3/16 1 0,89 35 (350) 6 1/4 1,5 1,65 35 (350) 8 5/16 1,5 1,65 35 (350) 10 3/8 1,5 1,65 35 (350) 12 1/2 2 2,1 31 (310) 16 5/8 2,5 2,41 24 (240) 20 3/4 3 2,77 24 (240) 22 7/8 3 2,77 21 (210) 25 1 3 3,05 21 (210) a Maximum wall thickness that can be flared, due to connector design. b For working pressure applications higher than those given in this table, the manufacturer shall be consulted. c 5 2 5 1 bar = 10 N/m = 10 Pa = 0,1 MPa.

ISO/FDIS 8434-2:2026(en) TTabablele 1 1 ((ccoonnttiinnueuedd)) Maximum wall thickness of b Tube outside diameter (OD) Maximum working pressure a tube for flaring Metric Inch Metric tube Inch tube Carbon steel and stainless steel 30 and 32 1 1/4 3 3,05 17 (170) 38 1 1/2 3 3,05 14 (140) 50 2 3,5 3,4 10,5 (105) a Maximum wall thickness that can be flared, due to connector design. b For working pressure applications higher than those given in this table, the manufacturer shall be consulted. c 5 2 5 1 bar = 10 N/m = 10 Pa = 0,1 MPa.

6 Designation of connectors

6.1 Connectors shall be designated by an alphanumeric code to facilitate ordering. They shall be designated by the word “Connector”, followed by ISO 8434-2, followed by a space, then the connector style letter symbols (see 6.2), followed by a hyphen, then, for the ends, the outside diameter of the tube with which they are to be connected, each separated by a multiplication symbol, ×. There shall be no space on either side of the multiplication symbol. For stud ends (connector ends), the thread designation of the stud end shall be added followed by a hyphen, and followed by connector material symbol. 6.2 The letter symbol designation of the connector style shall have three parts: a) the connection end type immediately followed by b) the shape of the connector and c) by the indication that a complete connector is being ordered. The letters A and B shall be used to distinguish different styles, where such options exist. 6.3 Tube ends are assumed to be external connections and thus do not need to be included in the connection type code. However, if another type of connection is involved, it shall be designated. 6.4 Reducing connectors and elbows shall be designated by specifying the larger tube end first. 6.5 Stud connectors shall be designated by specifying the tube end first, then the thread size for the stud end.

6.6 For tee connectors, the order of designation of the connection ends shall be from the larger to the smaller tube end on the run, followed by the branch end.

6.7 For cross connectors, the order of designation of the connection ends shall be from left to right, followed by from top to bottom, with the larger ends on the left and at the top. 6.8 The following letter symbols shall be used:

Connection end type Letter Bulkhead BH Swivel SW Reducer RD Stud SD Shape Letter Straight S

ISO/FDIS 8434-2:2026(en) 90° elbow E 45° elbow E45 Tee T Run tee RT Branch tee BT Cross K Long L Component type Letter Nut N Sleeve SL Locknut LN Plug PL Cap CP Nipple NP Metric M Inch I Completeness indication Letter Complete connector C Stud end sealing types Letter Metal-to-metal sealing B Elastomeric sealing E O-ring sealing F Material Letter Steel S Stainless steel SS 6.9 Examples of 37° flared connectors and designations are given in Figures 3 and 4. EXAMPLE A straight stud connector (SDS), including O-ring without sleeve and nut, for use with 12 mm OD tubing with an 3/4-16 UNF stud end in accordance with ISO 11926-3, made with steel, is designated for ordering as follows:

ConnectorISO 8434-2SDS-12×3/4-16F-S

ISO/FDIS 8434-2:2026(en) Figure 3 — Straight stud connector (SDS) with stud end in accordance with ISO 11926-3 EXAMPLE A complete straight stud connector (SDSC), including O-ring with sleeve and nut, for use with 12 mm OD tubing with an M16 × 1,5 stud end in accordance with ISO 6149-3, made with stainless steel, is designated for ordering as follows:

ConnectorISO 8434-2SDSC-12×M16F-SS Figure 4 — Straight stud connector, complete (SDSC) with stud end in accordance with ISO 6149-3 (sealing type F)

7 Requirements for tubes

7.1 The connectors shall be suitable for use with tubes with dimensions as given in Table 2 and Table 3. The outside diameter tolerances include ovality. Tubes shall be free of scratches, damage, and imperfections that would be considered detrimental to the function of the tubing.

7.2 Carbon steel tubes

7.2.1 Carbon steel tubes shall be seamless, cold drawn, and normalized. The steel tubes shall be weldable and the content of carbon in its chemical composition shall not exceed 0,22 %. 7.2.2 Mechanical properties in normalized condition at room temperature shall be as follows. Yield strength: R : 225 MPa eh min.

Tensile strength: R : 340 to 630 MPa m Elongation after fracture: A : 25 % for R < 480 MPa min. m 22 % for R 480 to 630 MPa m 7.2.3 The following surface protections are recommended.

Tubes for welding purpose: phosphated or unplated.

Tubes for flaring purpose: zinc plated, passivated, phosphated, or unplated. Plating applied should not exceed the tube outside diameter tolerance specified in Table 2 and Table 3 and shall be compatible with the flaring process such that flare quality and cleanliness are not impacted.

ISO/FDIS 8434-2:2026(en) 7.2.4 Inspection and testing documentation shall be provided which contain at least the following information:

  • chemical analysis;
  • tensile testing (see ISO 6892-1);
  • tube forming drift expanding testing (see ISO 8493);
  • dimensional inspection;
  • non-destructive testing for the verification of hydraulic leaktightness (see ISO 10893-1);
  • non-destructive testing for the detection of longitudinal imperfections (see ISO 10893-10);
  • plating information.

7.3 Stainless steel tubes

7.3.1 Stainless steel tubes shall comply with ISO 1127.

7.3.2 Stainless steel tubes shall be cold-drawn, solution annealed, and scale-free. Tubes made of stainless steel shall be suitable for welding.

7.3.3 Mechanical properties after heat treatment at room temperature shall be as follows:

Yield strength: R : 245 MPa p0,2 min.

Tensile strength: R : 500 to 730 MPa m Elongation after fracture: A : 35 % min.

Reference hardness: max. 90 HRB in accordance with ISO 6508-1 7.3.4 Inspection and testing documentation shall be provided which contain at least the following information:

  • chemical analysis;
  • tensile testing (see ISO 6892-1);
  • tube forming drift expanding testing (see ISO 8493) or Ring-expanding test (see ISO 8495);
  • resistance to intergranular corrosion (see ISO 3651-2);
  • dimensional inspection;
  • non-destructive testing for the verification of hydraulic leaktightness (see ISO 10893-1);
  • non-destructive testing for the detection of longitudinal imperfections (see ISO 10893-10).

ISO/FDIS 8434-2:2026(en) Table 2 — Metric tube sizes Tube OD Limits of OD mm mm min. max.

4 3,9 4,1 5 4,9 5,1 6 5,9 6,1 8 7,9 8,1 10 9,9 10,1 12 11,9 12,1 16 15,9 16,1 20 19,9 20,1 22 21,9 22,1 25 24,9 25,1 30 29,85 30,15 32 31,85 32,15 38 37,85 38,15 50 49,8 50,2 Metric tubing shall be preferred.

Table 3 — Inch tube sizes Tube OD Limits of OD mm a in mm min. max.

1/8 3,18 3,08 3,28 3/16 4,76 4,66 4,86 1/4 6,35 6,25 6,45 5/16 7,94 7,84 8,04 3/8 9,52 9,42 9,62 1/2 12,7 12,6 12,8 5/8 15,88 15,78 15,98 3/4 19,05 18,95 19,15 7/8 22,22 22,12 22,32 1 25,4 25,3 25,5 1 1/4 31,75 31,6 31,9 1 1/2 38,1 37,95 38,25 2 50,8 50,6 51 a Equivalent dimension in millimetres.

8 Across flats dimensions and tolerances

8.1 The dimensions across flats of elbow, tee and cross connectors shall be as shown in the respective tables with minus tolerance only. For sizes up to and including 24 mm, tolerances for across flats dimensions 0 0 for forgings shall be mm, and for sizes larger than 24 mm, they shall be mm. The basic forging size −0,8 −1,0 may be increased up to the maximum size shown for barstock, but the size selected shall be a metric across-flat size with minus tolerance only.

ISO/FDIS 8434-2:2026(en) 8.2 Hex tolerances shall be in accordance with ISO 4759-1, product grade C. Minimum across corner hex dimensions are 1,092 times the nominal width across flats. The minimum side flat is 0,43 times the nominal width across flats, unless otherwise specified or shown, hex corners shall be chamfered 15° to 30° to a

diameter equal to the width across flats, with a tolerance of mm. −0,4

9 Design

9.1 Connectors

The connectors shall conform to the requirements given in Figures 5 to 19 and Tables 6 to 20. They shall be designed so that resistance to flow is reduced to a minimum.

9.2 Dimensions

Dimensions specified apply to finished parts, including any plating or other treatments. The tolerance value for all dimensions not otherwise limited shall be ±0,4 mm. The sealing seats of connectors shall be concentric, with straight thread pitch diameters within 0,25 mm full indicator reading (FIR).

9.3 Passage tolerances

Where passages in straight connectors are machined from opposite ends, the offset at the meeting point shall not exceed 0,4 mm. No cross-sectional area at a junction of passages shall be less than that of the smallest passage.

9.4 Wall thickness

Unless otherwise designated, the wall thickness at any point on the connectors shall not be less than the thickness established by the specified dimensions, tolerances, and eccentricities for inner and outer surfaces.

9.5 Angular tolerances

Angular tolerance on axes of end on elbows, tees, and crosses shall be ±2,5° for tube sizes up to and including 10 mm and ±1,5° for all larger sizes.

9.6 Contour details

Details of contour shall be chosen by the manufacturer, provided the dimensions given in Tables 6 to 20 are maintained. Wrench flats on elbows, tees, and crosses shall conform to the dimensions given in the relevant tables. Abrupt reduction of a section shall be avoided. Junctions of small external sections and adjoining sections that are relatively heavy shall be blended by means of ample fillets.

9.7 Stud ends

The dimensions for the stud ends shall conform to those given in ISO 6149-3. Stud ends in accordance with ISO 1179-3, ISO 9974-2 and ISO 11926-3 shall not be used for new designs in fluid power applications.

9.8 Reducing connectors

Dimension of reducing connectors shall be in accordance with Annex A.

ISO/FDIS 8434-2:2026(en)

10 Screw threads

10.1 37° flared ends The screw threads on the tube flared ends of the connectors shall be ISO inch screw threads in accordance with ISO 725. Straight threads shall be class 2A or 2B, except external threads which are plated or coated may exceed 2A diameters but shall not exceed maximum of 3A diameters. Internal threads of all classes shall be within specified limits after plating or coating.

...

Contents

  • Introduction
  • 1 Scope
  • 2 Normative references
  • 3 Terms and definitions
  • 4 Materials
  • 4.1 General
  • 5 O-ring
  • 4.2 Connector bodies
  • 4.3 Nuts
  • 4.4 Sleeves
  • 5 Pressure and temperature requirements
  • 6 Designation of connectors
  • 7 Requirements for tubes
  • 8 Across flats dimensions and tolerances
  • 9 Design
  • 9.1 Connectors
  • 9.2 Dimensions
  • 9.3 Passage tolerances
  • 9.4 Wall thickness
  • 9.5 Angular tolerances
  • 9.6 Contour details
  • 9.7 Stud ends
  • 9.8 Reducing connectors
  • 10 Screw threads
  • 10.2 Stud ends (connection ends)
  • 11 Manufacture
  • 11.1 Construction
  • 11.2 Workmanship
  • 11.3 Corrosion protection
  • 11.4 Connector protection
  • 11.5 Corners
  • 12 Assembly instructions
  • 13 Procurement information
  • 14 Marking of components
  • 15 Performance and qualification test
  • 15.1 Performance requirements
  • 16 Identification statement
  • 4 × 4 4 5/16-24 1,6 29,7 19,6 5,6 11 12 -
  • 5 × 5 5 3/8-24 UNF 3,2 31,2 21,1 5,6 11 12 -
  • Annex A
  • Bibliography

Introduction

In fluid power systems, power is transmitted and controlled through a fluid (liquid or gas) under pressure within an enclosed circuit. In general applications, a fluid may be conveyed under pressure. Components may be connected through their ports by connections (connectors), tubes and hoses. Tubes are rigid conductors; hoses are flexible conductors.

[1][1] [2] [3] This document is based on the US standard ANSI/SAE J514-1 and SAE J533 . . The threads for the 37° flared connection are unified inch threads in accordance with ISO 725. The inch threads were not changed to metric threads according to ISO 261 to allow connectors complying with this document to be used in existing applications without requiring a change to tube or hose assemblies. Also, the thread-to-nut overtightening and seal performance have been extensively tested; to change to metric threads would require an extensive test program at considerable cost without providing any functional improvement. The threads are integral to themselves, connectors of this type match only to themselves and, other than having metric threads, no value in changing could be found. Major international companies that have used these connectors have adopted the design without noting any problems. All wrench flats specified in this document are dimensioned to be used with ISO standard metric wrenches.

ISO/FDIS 8434-2:2026(en) Metallic tube connections for fluid power and general use — Part 2:

37° flared connectors Part 2:

37 degree flared connectors

1 Scope

This document specifies the general and dimensional requirements for the design and performance of 37° flared connectors that are suitable for use with ferrous and non-ferrous tubes with outside diameters from 4 mm to 50,8 mm, inclusive. These connectors provide full-flow connections with metal-to-metal sealings. These connectors are for use in fluid power and general applications within the limits of pressure and temperature specified in this document.

They are intended for the connection of tubes and hose fittings to ports in accordance with ISO 6149--1, ISO 1179--1, ISO 9974--1 and ISO 11926--1. (See ISO 12151--5 for related hose fitting specification.) NOTE 1 For new designs in hydraulic fluid power applications, see the requirements given in 9.79.7.. Where the requirements of the application allow for the use of elastomeric seals, connector designs that conform to International Standards and incorporate elastomeric sealing are preferred.

NOTE 2 For use under conditions outside the limits for pressure or temperature, or both, see 5.45.4.. Both metric and inch tubing can be accommodated by changing the sleeve (see Figure 9Figure 9).). In the past, these connectors have been used predominantly with inch tubing. For new and future designs, the use of metric tubing is preferred.

This document also specifies performance and qualification tests for 37° flared connectors.

2 Normative references

The following documents are referred to in the text in such a way that some or all of their content constitutes requirements of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. ISO 725, ISO inch screw threads — Basic dimensions ISO 1127, Stainless steel tubes — Dimensions, tolerances and conventional masses per unit length ISO 1179--3, Connections for general use and fluid power — Ports and stud ends with ISO 228-1 threads with elastomeric or metal-to-metal sealing — Part 3: Light-duty (L series) stud ends with sealing by O-ring with retaining ring (types G and H)) ISO 4759--1, Tolerances for fasteners — Part 1: Bolts, screws, studs and nuts — Product grades A, B and C ISO 5598, Fluid power systems and components — Vocabulary ISO 6149--3, Connections for hydraulic fluid power and general use — Ports and stud ends with ISO 261 metric threads and O-ring sealing — Part 3: Dimensions, design, test methods and requirements for light-duty (L series) stud ends ISO 9227, Corrosion tests in artificial atmospheres — Salt spray tests

ISO/FDIS 8434-2:2026(en) ISO 9974--2, Connections for general use and fluid power — Ports and stud ends with ISO 261 threads with elastomeric or metal-to-metal sealing — Part 2: Stud ends with elastomeric sealing (type E)) ISO 11926--3, Connections for general use and fluid power — Ports and stud ends with ISO 725 threads and O- ring sealing — Part 3: Light-duty (L series) stud ends ISO 19879, Metallic tube connections for fluid power and general use — Test methods for hydraulic fluid power connections ISO 21920-1, Geometrical product specifications (GPS) — Surface texture: Profile — Part 1: Indication of surface texture

3 Terms and definitions

For the purposes of this document, the terms and definitions given in ISO 5598 and the following apply. ISO and IEC maintain terminology databases for use in standardization at the following addresses:

  • — ISO Online browsing platform: available at https://www.iso.org/obp
  • — IEC Electropedia: available at https://www.electropedia.org/ 3.1 3.1 adjustable stud end stud end connector that allows for connector orientation through final tightening of the locknut to complete the connection Note 1 to entry: This type of stud end is typically used on shaped connectors (e.g. tees, crosses and elbows). 3.2 3.2 non-adjustable stud end stud end connector that does not require specific orientation before final tightening of the connection because it is only used on straight connectors 3.3 3.3 run two principal, axially aligned outlets of a tee connector or cross connector 8434-2_ed3fig1.EPS

Key 1 run 2 branch Figure 1 — Run and branch illustration 3.4 3.4 branch side outlet(s) of a tee connector or cross connector

ISO/FDIS 8434-2:2026(en) 3.5 3.5 chamfer removal of a conical portion at the entrance of a thread to assist assembly and prevent damage to the start of the thread 3.6 3.6 assembly torque torque required to achieve a satisfactory final connection 3.7 3.7 qualification test torque torque used to verify conformity of the connector to the requirements of this document 3.8 3.8 overtightening torque that the nut withstands without deformation that renders it unusable 3.9 3.9 jump size connector connectorsconnector with dis-similar end connections, for example, -–6 male flare with a -–12 stud end

4 Materials

4.1 General

Figure 2Figure 2 shows the cross-section and components of a typical 37° flared connector. 8434-2_ed3fig2.EPS

Key 1 straight stud connector body 2 tube nut 3 tube 4 sleeve

5 O-ring

a Stud end in accordance with ISO 1179-3, ISO 6149-3, ISO 9974-2 or ISO 11926-3. Figure 2 — Cross-section of typical 37° flared connection

ISO/FDIS 8434-2:2026(en)

4.2 Connector bodies

Bodies shall be manufactured from carbon steel or stainless steel, which will provide the minimum requirements for the pressure and temperature ratings specified in Clause 5Clause 5 when tested in accordance with Clause 15Clause 15.. They shall have characteristics that make them suitable for use with the fluid to be conveyed and to provide an effective joint.

4.3 Nuts

Nuts to be used with carbon steel bodies shall be made of carbon steel and those for use with stainless steel bodies shall be made of stainless steel unless otherwise specified.

4.4 Sleeves

Sleeves shall be manufactured from a material similar to the bodies.

5 Pressure and temperature requirements

5.1 5.1 The working pressure of the connector shall be the lower of the working pressure of the 37° flared connector connection given in Table 1Table 1 and the working pressure of the respective stud end.

5.2 5.2 Flared connectors in accordance with this document made of carbon steel shall meet or exceed without leakage the requirements to the working pressures given in Table 1Table 1 when used at temperatures from −40 °C to +120 °C with petroleum base hydraulic fluids. 5.3 5.3 Connectors made of stainless steel complying with this document shall be suitable for use at the working pressures given in Table 1Table 1 when used at temperatures from −60 °C to +50 °C. 5.4 5.4 For applications under conditions outside the limits for pressure or temperature, or both given in Table 1Table 1 and in 5.25.2 and 5.35.3,, the manufacturer shall be consulted. 5.5 5.5 Connectors conforming to this document shall be tested in accordance with Clause 15Clause 15 to ensure that they meet or exceed the pressure requirements given in Table 1Table 1..

5.6 5.6 The pressure and temperature requirements given in Table 1Table 1 and in 5.25.2 and 5.35.3 are for tube connections and connector bodies only. For port and stud end pressure and temperature ratings, the values in the respective port and stud end standards shall apply. 5.7 5.7 To achieve these maximum working pressures with a 4:1 design factor, the maximum tube wall thicknesses shown in Table 1Table 1 are sufficient. See ISO 10763 to confirm the necessary tube wall thickness for a specific working pressure.

Table 1 — Working pressures for 37° flared connections Tube outside diameter Maximum wall thickness of Maximum working a b (OD) tube for flaring pressure Carbon steel and stainless Metric Inch Metric tube Inch tube steel

mm in mm mm MPa (bar) 4 1/8 1 0,89 35 (350) 5 3/16 1 0,89 35 (350) 6 1/4 1,5 1,65 35 (350)

ISO/FDIS 8434-2:2026(en) Tube outside diameter Maximum wall thickness of Maximum working a b (OD) tube for flaring pressure Carbon steel and stainless Metric Inch Metric tube Inch tube steel 8 5/16 1,5 1,65 35 (350) 10 3/8 1,5 1,65 35 (350) 12 1/2 2 2,1 31 (310) 16 5/8 2,5 2,41 24 (240) 20 3/4 3 2,77 24 (240) 22 7/8 3 2,77 21 (210) 25 1 3 3,05 21 (210) 30 and 32 1 1/4 3 3,05 17 (170) 38 1 1/2 3 3,05 14 (140) 50 2 3,5 3,4 10,5 (105) a Maximum wall thickness that can be flared, due to connector design. b For working pressure applications higher than those given in this table, the manufacturer shall be consulted. 5 2 5 c 1 bar = 10 N/m = 10 Pa = 0,1 MPa.

6 Designation of connectors

6.1 6.1 Connectors shall be designated by an alphanumeric code to facilitate ordering. They shall be designated by the word “Connector”, followed by ISO 8434-2, followed by a space, then the connector style letter symbols (see 6.26.2),), followed by a hyphen, then, for the ends, the outside diameter of the tube with which they are to be connected, each separated by a multiplication symbol, ×. There shall be no space on either side of the multiplication symbol. For stud ends (connector ends), the thread designation of the stud end shall be added followed by a hyphen, and followed by connector material symbol. 6.2 6.2 The letter symbol designation of the connector style shall have three parts: a) the connection end type immediately followed by b) the shape of the connector and c) by the indication that a complete connector is being ordered. The letters A and B shall be used to distinguish different styles, where such options exist.

6.3 6.3 Tube ends are assumed to be external connections and thus do not need to be included in the connection type code. However, if another type of connection is involved, it shall be designated. 6.4 6.4 Reducing connectors and elbows shall be designated by specifying the larger tube end first. 6.5 6.5 Stud connectors shall be designated by specifying the tube end first, then the thread size for the stud end.

6.6 6.6 For tee connectors, the order of designation of the connection ends shall be from the larger to the smaller tube end on the run, followed by the branch end.

6.7 6.7 For cross connectors, the order of designation of the connection ends shall be from left to right, followed by from top to bottom, with the larger ends on the left and at the top. 6.8 6.8 The following letter symbols shall be used:

Connection end type Letter

ISO/FDIS 8434-2:2026(en) Bulkhead BH Swivel SW Reducer RD Stud SD Shape Letter Straight S 90° elbow E 45° elbow E45 Tee T Run tee RT Branch tee BT Cross K Long L Component type Letter Nut N Sleeve SL Locknut LN Plug PL Cap CP Nipple NP Metric M Inch I Completeness indication Letter Complete connector C Stud end sealing types Letter Metal-to-metal sealing B Elastomeric sealing E O-ring sealing F Material Letter Steel S Stainless steel SS 6.9 6.9 Examples of 37° flared connectors and designations are given in Figures 3Figures 3 and 44.. EXAMPLE A straight stud connector (SDS), including O-ring without sleeve and nut, for use with 12 mm OD tubing with an 3/4-16 UNF stud end in accordance with ISO 11926-3, made with steel, is designated for ordering as follows:

Connector ISOConnectorISO 8434-2 SDS2SDS-12×3/4-16F-S

ISO/FDIS 8434-2:2026(en) 8434-2_ed3fig3.EPS

Figure 3 — Straight stud connector (SDS) with stud end in accordance with ISO 11926-3 EXAMPLE A complete straight stud connector (SDSC), including O-ring with sleeve and nut, for use with 12 mm OD tubing with an M16 × 1,5 stud end in accordance with ISO 6149-3, made with stainless steel, is designated for ordering as follows:

Connector ISOConnectorISO 8434-2 SDSC2SDSC-12×M16F-SS 8434-2_ed3fig4.EPS

Figure 4 — Straight stud connector, complete (SDSC) with stud end in accordance with ISO 6149-3 (sealing type F)

7 Requirements for tubes

7.1 7.1 The connectors shall be suitable for use with tubes with dimensions as given in Table 2Table 2 and Table 3Table 3.. The outside diameter tolerances include ovality. Tubes shall be free of scratches, damage, and imperfections that would be considered detrimental to the function of the tubing. 7.2 7.2 Carbon steel tubes 7.2.1 7.2.1 Carbon steel tubes shall be seamless, cold drawn, and normalized. The steel tubes shall be weldable and the content of carbon in its chemical composition shall not exceed 0,22 %. 7.2.2 7.2.2 Mechanical properties in normalized condition at room temperature shall be as follows. Yield strength: R : 225 MPa eh min.

Tensile strength: R : 340 to 630 MPa m Elongation after fracture: A : 25 % for R < 480 MPa min. m 22 % for R 480 to 630 MPa m 7.2.3 7.2.3 The following surface protections are recommended. Tubes for welding purpose: phosphated or unplated.

ISO/FDIS 8434-2:2026(en) Tubes for flaring purpose: zinc plated, passivated, phosphated, or unplated. PlatingsPlating applied should not exceed the tube outside diameter tolerance specified in Table 2Table 2 and Table 3Table 3 and shall be compatible with the flaring process such that flare quality and cleanliness are not impacted.

7.2.4 7.2.4 Inspection and testing documentation shall be provided which contain at least the following information:

  • — chemical analysis;
  • — tensile testing (see ISO 6892-1);
  • — tube forming drift expanding testing (see ISO 8493);
  • — dimensional inspection;
  • — non-destructive testing for the verification of hydraulic leaktightness (see ISO 10893-1);
  • — non-destructive testing for the detection of longitudinal imperfections (see ISO 10893-10);
  • — plating information.

7.3 7.3 Stainless steel tubes 7.3.1 7.3.1 Stainless steel tubes shall comply with ISO 1127.

7.3.2 7.3.2 Stainless steel tubes shall be cold-drawn, solution annealed, and scale-free. Tubes made of stainless steel shall be suitable for welding.

7.3.3 7.3.3 Mechanical properties after heat treatment at room temperature shall be as follows:

Yield strength: R : 245 MPa p0,2 min.

Tensile strength: R : 500 to 730 MPa m Elongation after fracture: A : 35 % min.

Reference hardness: max. 90 HRB in accordance with ISO 6508-1 7.3.4 7.3.4 Inspection and testing documentation shall be provided which contain at least the following information:

  • — chemical analysis;
  • — tensile testing (see ISO 6892-1);
  • — tube forming drift expanding testing (see ISO 8493) or Ring-expanding test (see ISO 8495);
  • — resistance to intergranular corrosion (see ISO 3651-2);
  • — dimensional inspection;
  • — non-destructive testing for the verification of hydraulic leaktightness (see ISO 10893-1);
  • — non-destructive testing for the detection of longitudinal imperfections (see ISO 10893-10).

ISO/FDIS 8434-2:2026(en)

Table 2 — Metric tube sizes Tube OD Limits of OD mm mm min. max.

4 3,9 4,1 5 4,9 5,1 6 5,9 6,1 8 7,9 8,1 10 9,9 10,1 12 11,9 12,1 16 15,9 16,1 20 19,9 20,1 22 21,9 22,1 25 24,9 25,1 30 29,85 30,15 32 31,85 32,15 38 37,85 38,15 50 49,8 50,2 Metric tubing shall be preferred.

Table 3 — Inch tube sizes Tube OD Limits of OD mm a in mm min. max.

1/8 3,18 3,08 3,28 3/16 4,76 4,66 4,86 1/4 6,35 6,25 6,45 5/16 7,94 7,84 8,04 3/8 9,52 9,42 9,62 1/2 12,7 12,6 12,8 5/8 15,88 15,78 15,98 3/4 19,05 18,95 19,15 7/8 22,22 22,12 22,32 1 25,4 25,3 25,5 1 1/4 31,75 31,6 31,9 1 1/2 38,1 37,95 38,25 2 50,8 50,6 51

ISO/FDIS 8434-2:2026(en) Tube OD Limits of OD mm a in mm min. max.

a Equivalent dimension in millimetres.

8 Across flats dimensions and tolerances

8.1 8.1 The dimensions across flats of elbow, tee and cross connectors shall be as shown in the respective tables with minus tolerance only. For sizes up to and including 24 mm, tolerances for across flats  𝟎𝟎  𝟎𝟎 dimensions for forgings shall be mm, and for sizes larger than 24 mm, they shall be mm. The basic −𝟎𝟎,𝟖𝟖 −𝟏𝟏,𝟎𝟎 forging size may be increased up to the maximum size shown for barstock, but the size selected shall be a metric across--flat size with minus tolerance only.

8.2 8.2 Hex tolerances shall be in accordance with ISO 4759-1, product grade C. Minimum across corner hex dimensions are 1,092 times the nominal width across flats. The minimum side flat is 0,43 times the nominal width across flats, unless otherwise specified or shown, hex corners shall be chamfered 15° to 30° to  𝟎𝟎 a diameter equal to the width across flats, with a tolerance of mm. −𝟎𝟎,𝟒𝟒

9 Design

9.1 Connectors

The connectors shall conform to the requirements given in Figures 5Figures 5 to 1919 and Tables 6Tables 6 to 2020.. They shall be designed so that resistance to flow is reduced to a minimum.

9.2 Dimensions

Dimensions specified apply to finished parts, including any plating or other treatments. The tolerance value for all dimensions not otherwise limited shall be ±0,4 mm. The sealing seats of connectors shall be concentric, with straight thread pitch diameters within 0,25 mm full indicator reading (FIR).

9.3 Passage tolerances

Where passages in straight connectors are machined from opposite ends, the offset at the meeting point shall not exceed 0,4 mm. No cross-sectional area at a junction of passages shall be less than that of the smallest passage.

9.4 Wall thickness

Unless otherwise designated, the wall thickness at any point on the connectors shall not be less than the thickness established by the specified dimensions, tolerances, and eccentricities for inner and outer surfaces.

9.5 Angular tolerances

Angular tolerance on axes of end on elbows, tees, and crosses shall be ±2,5° for tube sizes up to and including 10 mm and ±1,5° for all larger sizes.

9.6 Contour details

Details of contour shall be chosen by the manufacturer, provided the dimensions given in Tables 6Tables 6 to 2020 are maintained. Wrench flats on elbows, tees, and crosses shall conform to the dimensions given in the relevant tables. Abrupt reduction of a section shall be avoided. Junctions of small external sections and adjoining sections that are relatively heavy shall be blended by means of ample fillets.

ISO/FDIS 8434-2:2026(en)

9.7 Stud ends

The dimensions for the stud ends shall conform to those given in ISO 6149-3. Stud ends in accordance with ISO 1179--3, ISO 9974--2 and ISO 11926--3 shall not be used for new designs in fluid power applications.

9.8 Reducing connectors

Dimension of reducing connectors shall be in accordance with Annex AAnnex A..

...

Contents

  • Introduction
  • 1 Domaine d'application
  • 2 Références normatives
  • 3 Termes et définitions
  • 3.1 extrémité filetée orientable
  • 3.2 extrémité filetée non orientable
  • 3.3 passage
  • 3.4 branche
  • 3.5 chanfrein
  • 3.6 couple de montage
  • 3.7 couple d'essai de qualification
  • 3.8 serrage excessif
  • 3.9 connecteur transition
  • 4 Matériaux
  • 4.1 Généralités
  • 4.2 Corps de connecteur
  • 4.3 Écrous
  • 4.4 Manchons
  • 5 Exigences de pression et de température
  • 5.5 Les connecteurs conformes au présent document doivent être soumis à essai conformément à
  • 6 Désignation des connecteurs
  • 7 Exigences pour les tubes
  • 7.1 Tubes en acier au carbone
  • 7.2 Tubes en acier inoxydable
  • 8 Dimensions et tolérances des cotes surplats
  • 9 Conception
  • 9.1 Connecteurs
  • 9.2 Dimensions
  • 9.3 Tolérances de passage
  • 9.4 Épaisseur de paroi
  • 9.5 Tolérances angulaires
  • 9.6 Détails du contour
  • 9.7 Extrémités filetées
  • 9.8 Connecteurs réduits
  • 10 Filetages
  • 10.1 Extrémités évasées à 37°
  • 10.2 Extrémités filetées (extrémités de raccordement)
  • 11 Fabrication
  • 11.1 Construction
  • 11.2 Qualité d'exécution
  • 11.3 Protection contre la corrosion
  • 11.4 Protection des connecteurs
  • 11.5 Arêtes
  • 12 Instructions de montage
  • 13 Informations relatives à l'achat
  • 14 Marquage des composants
  • 15 Essais de performance et de qualification
  • 15.1 Exigences de performance
  • 16 Phrase d'identification
  • 4 × 4 4 5/16-24 UNF 1,6 29,7 19,6 5,6 11 12 -
  • 5 × 5 5 3/8-24 UNF 3,2 31,2 21,1 5,6 11 12 -
  • Annexe A
  • Bibliographie

Introduction

Dans les systèmes de transmissions hydrauliques et pneumatiques, l'énergie est transmise et commandée par l'intermédiaire d'un fluide (liquide ou gaz) sous pression circulant dans un circuit fermé. Dans les applications générales, le fluide peut être véhiculé sous pression. Les composants peuvent être connectés à travers leurs orifices par des connexions (connecteurs) et des conducteurs (tubes et tuyaux). Les tubes sont des conducteurs rigides; les tuyaux sont des conducteurs flexibles.

[1] [2] Le présent document est basé sur les normes américaines SAE J514-1 et ANSI J533. Les filetages du connecteur évasé à 37° sont des filetages en inches conformes à l'ISO 725. Les filetages en inches n'ont pas été convertis en filetages métriques conformes à l'ISO 261 pour permettre d'utiliser des connecteurs conformes au présent document dans des applications existantes sans avoir à modifier les assemblages tubes ou tuyaux. En outre, le rapport de serrage excessif et les performances du joint ont fait l'objet d'essais extensifs; passer aux filetages métriques exigerait un programme d'essais extensifs à un coût très élevé sans apporter d'amélioration fonctionnelle. Les filetages sont incorporés, les connecteurs de ce type ne s'adaptent qu'à eux-mêmes et, si ce n'est le fait d'avoir des filetages métriques, aucun avantage n'a été trouvé à les changer. Les grandes sociétés internationales qui ont utilisé ces connecteurs ont adopté la conception sans noter de problème. Tous les surplats de serrage spécifiés dans le présent document sont dimensionnés pour être utilisés avec des clés métriques normalisées ISO.

PROJET FINAL Norme internationale ISO/FDIS 8434-2:2026(fr) Raccordements de tubes métalliques pour transmissions hydrauliques et pneumatiques et applications générales — Partie 2:

Connecteurs évasés à 37 degrés

1 Domaine d'application

Le présent document spécifie les exigences générales et dimensionnelles pour la conception et la performance des connecteurs évasés à 37° qui sont adaptés à une utilisation avec des tubes ferreux et non ferreux ayant des diamètres extérieurs de 4 mm à 50,8 mm inclus. Ces connecteurs offrent des raccordements plein débit avec étanchéité métal sur métal. Ces connecteurs sont utilisés dans les transmissions hydrauliques et pneumatiques et les applications générales dans les limites de pression et de température spécifiées dans le présent document.

Ils sont prévus pour le raccordement de tubes et de tuyaux à des orifices conformes à l'ISO 6149-1, ISO 1179-1, ISO 9974-1 et ISO 11926-1. (Voir l'ISO 12151-5 pour les spécifications relatives aux raccordements flexibles.) NOTE 1 Pour les nouvelles conceptions pour des applications de transmissions hydrauliques, voir les exigences données en 9.7. Dans les cas où les exigences de l'application permettent l'utilisation de joints en élastomères, la conception des connecteurs nécessite de se conformer aux Normes internationales et incorporer de préférence des joints élastomères.

NOTE 2 Pour des utilisations en dehors des limites de températures ou de pressions, ou les deux, voir 5.4. Les tubes métriques et les tubes en inches peuvent être adaptés en changeant le manchon (voir Figure 9). Dans le passé, ces connecteurs ont surtout été utilisés avec des tubes en inches. Pour les nouvelles et futures conceptions, l'utilisation de tubes métriques est préférable.

Le présent document spécifie également des essais de performance et de qualification relatifs à ces connecteurs évasés à 37°.

2 Références normatives

Les documents suivants sont cités dans le texte de sorte qu’ils constituent, pour tout ou partie de leur contenu, des exigences du présent document. Pour les références datées, seule l’édition citée s’applique. Pour les références non datées, la dernière édition du document de référence s'applique (y compris les éventuels amendements).

ISO 725, Filetages ISO en inches — Dimensions de base ISO 1127, Tubes en acier inoxydable — Dimensions, tolérances et masses linéiques conventionnelles ISO 1179-3, Raccordements pour applications générales et transmissions hydrauliques et pneumatiques — Orifices et éléments mâles à filetage ISO 228-1 et joint en élastomère ou étanchéité métal sur métal — Partie 3:

Éléments mâles série légère (série L) avec étanchéité par joint torique et bague de retenue (types G et H) ISO 4759-1, Tolérances des éléments de fixation — Partie 1: Vis, goujons et écrous — Grades A, B et C ISO 5598, Transmissions hydrauliques et pneumatiques — Vocabulaire

ISO/FDIS 8434-2:2026(fr) ISO 6149-3, Raccordements pour transmissions hydrauliques et applications générales — Orifices et éléments mâles à filetage métrique ISO 261 et joint torique — Partie 3: Dimensions, conception, méthodes d'essai et exigences des éléments mâles de série légère (série L) ISO 9227, Essais de corrosion en atmosphères artificielles — Essais aux brouillards salins ISO 9974-2, Raccordements pour applications générales et transmissions hydrauliques et pneumatiques — Orifices et éléments mâles à filetage ISO 261 et joint en élastomère ou étanchéité métal sur métal — Partie 2:

Éléments mâles avec joint en élastomère (type E) ISO 11926-3, Raccordements pour applications générales et transmissions hydrauliques et pneumatiques — Orifices et éléments mâles à filetage ISO 725 et joint torique — Partie 3: Éléments mâles de série légère (série L) ISO 19879, Raccords de tubes métalliques pour transmissions hydrauliques et pneumatiques et applications générales — Méthodes d'essai pour raccords pour transmissions hydrauliques ISO 21920-1, Spécification géométrique des produits (GPS) — État de surface: Méthode du profil — Partie 1:

Indication des états de surface

3 Termes et définitions

Pour les besoins du présent document, les termes et définitions donnés dans l'ISO 5598 ainsi que les suivants s'appliquent.

L'ISO et l'IEC tiennent à jour des bases de données terminologiques destinées à être utilisées en normalisation, consultables aux adresses suivantes:

  • ISO Online browsing platform: disponible à l'adresse https:// www .iso .org/ obp
  • IEC Electropedia: disponible à l'adresse https:// www .electropedia .org/

3.1 extrémité filetée orientable

embout fileté permettant d'orienter le connecteur avant le dernier serrage du contre-écrou assurant le raccordement Note 1 à l'article: Ce type d'extrémité filetée est généralement utilisé sur les connecteurs façonnés (par exemple tés, croix et coudes).

3.2 extrémité filetée non orientable

embout fileté n'exigeant pas une orientation particulière avant le dernier serrage de raccordement parce qu'il n'est utilisé que sur des connecteurs droits

3.3 passage

alignement des deux orifices de sortie d'un connecteur en té ou en croix Légende 1 passage 2 branche Figure 1 — Illustration d'un passage et d'une branche

ISO/FDIS 8434-2:2026(fr)

3.4 branche

sortie(s) latérale(s) d'un connecteur en té ou d'un connecteur en croix

3.5 chanfrein

suppression d'une portion conique à l'entrée d'un filetage pour aider à l'assemblage et éviter de détériorer le début du filetage

3.6 couple de montage

couple nécessaire pour assurer un assemblage final satisfaisant

3.7 couple d'essai de qualification

couple utilisé pour vérifier la conformité du connecteur aux exigences du présent document

3.8 serrage excessif

couple que l'écrou supporte sans déformation le rendant inutilisable

3.9 connecteur transition

connecteur dont les extrémités des raccordements sont différentes, par exemple, un embout mâle −6 avec une extrémité filetée −12

4 Matériaux

4.1 Généralités

La Figure 2 présente la coupe transversale et les éléments d'un connecteur évasé à 37° type.

ISO/FDIS 8434-2:2026(fr) Légende 1 corps de connecteur droit 2 écrou de tube 3 tube 4 manchon 5 joint torique a Extrémité filetée conforme à l'ISO 1179-3, ISO 6149-3, ISO 9974-2 ou ISO 11926-3. Figure 2 — Coupe transversale d'un connecteur évasé à 37° type

4.2 Corps de connecteur

Les corps doivent être fabriqués en acier au carbone ou en acier inoxydable satisfaisant au minimum aux exigences de pression et température applicables spécifiées à l'Article 5 lorsqu'ils sont soumis à essai conformément à l'Article 15. Leurs caractéristiques doivent les rendre aptes à l'usage avec le fluide à transporter et à assurer une étanchéité effective.

4.3 Écrous

Sauf indication contraire, les écrous utilisés avec les corps en acier au carbone doivent être en acier au carbone et ceux utilisés avec les corps en acier inoxydable doivent être en acier inoxydable.

4.4 Manchons

Les manchons doivent être réalisés dans un matériau similaire à celui des corps.

5 Exigences de pression et de température

5.1 La pression de service du connecteur doit être la plus faible des pressions suivantes: la pression de service du raccordement à connecteur évasé à 37° donnée au Tableau 1 et la pression de service de l'extrémité filetée respective.

5.2 Les connecteurs évasés conformes au présent document, fabriqués en acier au carbone doivent atteindre ou dépasser sans fuite les exigences relatives aux pressions de service données au Tableau 1 lorsqu'ils sont utilisés à des températures comprises entre −40 °C et +120 °C avec des fluides hydrauliques à base de pétrole.

ISO/FDIS 8434-2:2026(fr) 5.3 Les connecteurs évasés conformes au présent document, fabriqués en acier inoxydable doivent être adaptés à une utilisation avec les pressions de service données au Tableau 1 lorsqu'ils sont utilisés à des températures comprises entre −60 °C et +50 °C.

5.4 Pour des applications se situant en dehors des limites de pression ou de température, ou les deux, données au Tableau 1 et en 5.2 et 5.3, le fabricant doit être consulté.

5.5 Les connecteurs conformes au présent document doivent être soumis à essai conformément à

l'Article 15 pour s'assurer qu'ils atteignent ou dépassent les exigences relatives aux pressions données au Tableau 1.

5.6 Les exigences de pression et de température données au Tableau 1 et en 5.2 et 5.3 ne valent que pour les raccordements de tubes et pour les corps de connecteurs. Les valeurs de pressions et de températures applicables aux orifices et aux extrémités filetées doivent être reprises des normes correspondantes. 5.7 Pour obtenir ces pressions maximales de service avec un coefficient de sécurité de 4:1, les épaisseurs maximales de tube présentées au Tableau 1 sont suffisantes. L'épaisseur de tube nécessaire pour une pression de service spécifique est à confirmer selon l'ISO 10763.

Tableau 1 — Pressions de service pour les raccordements évasés à 37° Diamètre extérieur du tube Épaisseur de paroi maximale Pression maximale a b (OD) du tube à évaser de service Tube Acier au carbone et Métrique Inches Tube métrique en inches acier inoxydable

mm in mm mm MPa (bar) 4 1/8 1 0,89 35 (350) 5 3/16 1 0,89 35 (350) 6 1/4 1,5 1,65 35 (350) 8 5/16 1,5 1,65 35 (350) 10 3/8 1,5 1,65 35 (350) 12 1/2 2 2,1 31 (310) 16 5/8 2,5 2,41 24 (240) 20 3/4 3 2,77 24 (240) 22 7/8 3 2,77 21 (210) 25 1 3 3,05 21 (210) 30 et 32 1 1/4 3 3,05 17 (170) 38 1 1/2 3 3,05 14 (140) 50 2 3,5 3,4 10,5 (105) a Épaisseur de paroi maximale pouvant être évasée, compte tenu de la conception du connecteur. b Pour des applications de pressions de service supérieures à celles données dans le présent tableau, le fabricant doit être consulté.

c 5 2 5 1 bar = 10 N/m = 10 Pa = 0,1 MPa

6 Désignation des connecteurs

6.1 Les connecteurs doivent être désignés par un code alphanumérique pour en faciliter la commande. Ils doivent être désignés par le terme «Connecteur» suivi par ISO 8434-2, suivi par un espace, puis des symboles littéraux du type de connecteur (voir 6.2), suivi d'un trait d'union, puis, pour les extrémités, des diamètres extérieurs des tubes auxquels elles sont connectées, chacun des diamètres étant séparé par un

ISO/FDIS 8434-2:2026(fr) signe de multiplication, × . Il ne doit pas y avoir d'espace de part et d'autre du symbole de multiplication. Pour les extrémités filetées (extrémités du connecteur), la désignation du filetage de l'extrémité filetée doit être ajoutée, suivie d'un trait d'union, puis du symbole du matériau du connecteur. 6.2 La désignation par symboles littéraux du type de connecteur doit comporter trois parties: a) le type d'extrémité de raccordement immédiatement suivi par b) la forme du connecteur et par c) l'indication qu'un connecteur complet est commandé. Les lettres A et B doivent être utilisées pour les différents styles, lorsque de telles options existent.

6.3 Les extrémités des tubes sont considérées comme des raccordements externes et n'ont donc pas besoin d'être incluses dans le code de type de connecteur. Toutefois, si un autre type de raccordement est concerné, celui-ci doit être désigné.

6.4 Les connecteurs et les coudes à passage réduit doivent être désignés en spécifiant en premier le diamètre de l'extrémité du tube la plus grande.

6.5 Les connecteurs goujonnés doivent être désignés en spécifiant l'extrémité du tube en premier, puis le diamètre de filetage de l'extrémité filetée.

6.6 Pour les connecteurs en té, l'ordre de désignation des extrémités de raccordement doit aller de la plus grande à la plus petite sur le passage, suivi de la branche.

6.7 Pour les connecteurs en croix, l'ordre de désignation des extrémités de raccordement doit se faire de gauche à droite, puis de haut en bas, avec les extrémités les plus grandes à gauche et en haut. 6.8 Les symboles littéraux suivants doivent être utilisés:

Type d'extrémité de raccordement Symbole Traversée de cloison BH Pivotant SW Réducteur RD Élément mâle SD Forme Symbole Droit S Coude à 90° E Coude à 45° E45 Té T Té renversé RT Branche BT Croix K Long L Type de composant Symbole Écrou N

ISO/FDIS 8434-2:2026(fr) Manchon SL Écrou de blocage LN Bouchon PL Chapeau CP Mamelon NP Métrique M Inches l Indication sur l'état complet Symbole Connecteur complet C Types d'étanchéité de l'extrémité filetée Symbole Étanchéité métal sur métal B Étanchéité élastomère E Étanchéité par joint torique F Matériau Symbole Acier S Acier inoxydable SS 6.9 Des exemples de connecteurs évasés à 37° et de désignations sont donnés aux Figures 3 et 4. EXEMPLE Un connecteur avec extrémité filetée droite (SDS), comprenant un joint torique sans manchon et écrou, pour utilisation avec des tubes de diamètre extérieur 12 mm et une extrémité filetée 3/4-16 UNF, fabriqué en acier, conforme à l'ISO 11926-3 est désigné comme suit pour la commande:

ConnecteurISO 8434-2SDS-12 × 3/4-16F-S Figure 3 — Connecteur avec extrémité filetée droite (SDS), avec extrémité filetée conforme à l'ISO 11926-3 EXEMPLE Un connecteur goujonné droit complet (SDSC), comprenant un joint torique avec manchon et écrou, pour utilisation avec des tubes de diamètre extérieur 12 mm et une extrémité filetée M16 × 1,5 conforme à l'ISO 6149-3, en acier inoxydable est désigné comme suit pour la commande:

ConnecteurISO 8434-2SDSC-12 × M16F-SS

ISO/FDIS 8434-2:2026(fr) Figure 4 — Connecteur avec extrémité filetée droite, complet (SDSC), avec extrémité filetée conforme à l'ISO 6149-3 (type d'étanchéité F)

7 Exigences pour les tubes

7.1 Les connecteurs doivent être utilisables avec des tubes dont les dimensions respectent celles données au Tableau 2 et au Tableau 3. Les tolérances sur le diamètre extérieur incluent l'ovalisation. Les tubes doivent être exempts de rayures, de dommages et d'imperfections qui pourraient être considérés comme nuisibles à la fonction du tube.

7.1 Tubes en acier au carbone

7.2.1 Les tubes en acier au carbone doivent être sans soudure, étirés à froid et normalisés. Les tubes en acier doivent être soudables et la teneur en carbone de leur composition chimique ne doit pas dépasser 0,22 %.

7.2.2 Les caractéristiques mécaniques à l'état normalisé à température ambiante doivent être les

suivantes.

Limite d'élasticité: R : 225 MPa eh min.

Résistance à la traction R : 340 à 630 MPa m Allongement après rupture: A : 25 % pour R < 480 MPa min. m 22 % pour R 480 à 630 MPa m 7.2.3 Les protections de surface suivantes sont recommandées.

Tubes pour le soudage: phosphatés ou sans revêtements.

Tubes pour évasement: zingués, passivés, phosphatés ou sans revêtements. Il convient que les placages appliqués ne dépassent pas la tolérance du diamètre extérieur du tube spécifiée dans le Tableau 2 et le Tableau 3 et doivent être compatibles avec le procédé d’évasement de manière à ce que la qualité et la propreté de l’évasement ne soient pas affectées. 7.2.4 Les documents de contrôle et d'essai doivent être fournis et contenir au moins les informations suivantes.

  • analyse chimique;
  • essai de traction (voir ISO 6892-1);
  • essai d'évasement de formage des tubes (voir ISO 8493);
  • contrôle dimensionnel;
  • essais non destructifs pour la vérification de l'étanchéité hydraulique (voir ISO 10893-1);

ISO/FDIS 8434-2:2026(fr) - essais non destructifs pour la détection des imperfections longitudinales (voir ISO 10893-10); - informations sur le placage.

7.2 Tubes en acier inoxydable

7.3.1 Les tubes en acier inoxydable doivent être conformes à l’ISO 1127. 7.3.2 Les tubes en acier inoxydable doivent être étirés à froid, recuits de mise en solution et exempts de calamine. Les tubes en acier inoxydable doivent pouvoir être soudés. 7.3.3 Les caractéristiques mécaniques après traitement thermique à température ambiante doivent être les suivantes:

Limite d'élasticité: R : 245 MPa p0,2 min.

Résistance à la traction R : 500 à 730 MPa m Allongement après rupture: A : 35 % min.

Dureté de référence: max. 90 HRB, conformément à l'ISO 6508-1 7.3.4 Les documents de contrôle et d'essai doivent être fournis et contenir au moins les informations suivantes:

  • analyse chimique;
  • essai de traction (voir ISO 6892-1);
  • essai d'évasement de formage des tubes (voir ISO 8493) ou Essai de dilatation d'anneaux (voir ISO 8495);
  • résistance à la corrosion intergranulaire (voir ISO 3651-2);
  • contrôle dimensionnel;
  • essais non destructifs pour la vérification de l'étanchéité hydraulique (voir ISO 10893-1);
  • essais non destructifs pour la détection des imperfections longitudinales (voir ISO 10893-10). Tableau 2 — Dimensions des tubes métriques Diamètre extérieur du tube Limites de diamètre extérieur mm mm min. max.

4 3,9 4,1 5 4,9 5,1 6 5,9 6,1 8 7,9 8,1 10 9,9 10,1 12 11,9 12,1 16 15,9 16,1 20 19,9 20,1 22 21,9 22,1 25 24,9 25,1 30 29,85 30,15 Les tubes métriques doivent être choisis de préférence.

ISO/FDIS 8434-2:2026(fr) TTabableleaauu 2 2 ((ssuuiitte)e) Diamètre extérieur du tube Limites de diamètre extérieur mm mm min. max.

32 31,85 32,15 38 37,85 38,15 50 49,8 50,2 Les tubes métriques doivent être choisis de préférence.

Tableau 3 — Dimensions des tubes en inches Diamètre extérieur Limites de diamètre extédu tube rieur mm a in mm min. max.

1/8 3,18 3,08 3,28 3/16 4,76 4,66 4,86 1/4 6,35 6,25 6,45 5/16 7,94 7,84 8,04 3/8 9,52 9,42 9,62 1/2 12,7 12,6 12,8 5/8 15,88 15,78 15,98 3/4 19,05 18,95 19,15 7/8 22,22 22,12 22,32 1 25,4 25,3 25,5 1 1/4 31,75 31,6 31,9 1 1/2 38,1 37,95 38,25 2 50,8 50,6 51 a Dimension équivalente en millimètres.

8 Dimensions et tolérances des cotes surplats

8.1 Les dimensions des cotes surplats des connecteurs coudés, en té et en croix doivent être telles que présentées dans les tableaux correspondants avec une tolérance minimale uniquement. Pour les dimensions inférieures ou égales à 24 mm, les tolérances pour les dimensions surplats de pièces forgées doivent être 0 0 égales à mm et, pour les dimensions supérieures à 24 mm, elles doivent être égales à mm. La −−0,8 −1,0 dimension de base de la pièce forgée peut être augmentée jusqu'à la dimension maximale indiquée pour les barres, mais la dimension choisie doit être une dimension métrique transversale avec une tolérance minimale seulement.

...