Abstract

Specifies a method for the determination of the refractory products at elevated temperatures, under conditions of a constant rate of increase of stress. A method for determination of the same property at ambient temperature is given in ISO 5014. The modulus of rupture is the ratio of the bending moment at the point of failure to the moment of resistance (the section modulus). It is calculated from an equation which is derived from Hooke' s Law for elastic materials.

Status
Not Published
Technical Committee
ISO/TC 33 - Refractories
Current Stage
6000 - International Standard under publication - 60 Publication
Start Date
17-Nov-2026

Buy Documents

Draft

ISO/FDIS 5013 - Refractory products — Determination of modulus of rupture at elevated temperatures

Release Date:07-Sep-2026
English language (13 pages)
sale 15% off
sale 15% off
Draft

REDLINE ISO/FDIS 5013 - Refractory products — Determination of modulus of rupture at elevated temperatures

Release Date:07-Sep-2026
English language (13 pages)
sale 15% off
sale 15% off

ISO 5013 is an ISO standard for determining the modulus of rupture of dense and insulating shaped refractory products at elevated temperatures. It specifies a three-point bending method under a constant rate of increase of stress, for laboratories testing refractory shapes and, after preparation, unshaped refractories. The document is used to measure hot bending strength in a controlled furnace, with defined specimen preparation, temperature control, and loading conditions.

What does ISO 5013 specify?

ISO 5013 specifies how to measure the modulus of rupture of refractory products at elevated temperatures and how to report the result. It covers dense and insulating shaped refractories, and it also applies to unshaped refractories after specimen preparation.

The document is organized around the full test sequence: scope, normative references, terms and definitions, principle, apparatus, test piece preparation, procedure, expression of results, and test report.

AnnexWhat it covers
Annex AHow to measure temperature distribution in the test piece and establish the relationship between furnace temperature and test temperature
Annex BPrecision and bias, based on interlaboratory study data

What are the key requirements of ISO 5013?

ISO 5013 controls the complete hot bending test so that results are comparable between laboratories. The most important requirements are in the apparatus, specimen preparation, heating, loading, calculation, and reporting clauses.

  • Clause 5 - apparatus. ISO 5013 requires a three-point bending test jig, a testing machine with constant loading rate and peak-load recording, a furnace suitable for batch or sequential heating, a calibrated thermocouple near the tensile face, a drying oven, and a calliper for dimensions. In practice, alignment, load control, and temperature measurement must be reliable because they directly affect the reported modulus of rupture.

  • Clause 6 - test pieces. ISO 5013 requires a representative sample, agreed sampling, and a defined number of test pieces per item. It also gives the standard test-piece form and preparation rules, including orientation relative to pressing direction when known. This matters because specimen shape, grain size, and extraction direction can change the measured strength.

  • Clause 6 and Clause 7 - specimen preparation and measurement. ISO 5013 requires test pieces to be prepared so that original surfaces and cutting effects are controlled, and the test-piece dimensions are measured before the hot test. The practical point is that the calculation uses the measured dimensions, so the lab must measure carefully and keep the specimen geometry within the specified tolerances.

  • Clause 7 - heating conditions. ISO 5013 requires the furnace atmosphere to be agreed between the parties concerned, the heating rate to be controlled, and the test temperature to be held until the temperature distribution in the specimen is uniform within the stated limit. This prevents the result from being distorted by thermal gradients.

  • Clause 7 - loading. ISO 5013 requires loading at a constant rate of increase of tensile stress until failure. The loading rate depends on the product type, and the time to failure must meet the stated minimum. In practice, the operator has to choose the load range and rate so the failure is recorded cleanly.

  • Clause 8 - calculation and expression. ISO 5013 calculates modulus of rupture from the maximum force at rupture, the support span, and the measured specimen dimensions. The result is reported in megapascals, to three significant figures, and Annex B discusses expected precision.

  • Clause 9 - test report. ISO 5013 requires the report to identify the laboratory, product, sample, specimen dimensions, pre-treatment, atmosphere, heating rate, test temperature, loading rate, individual results, mean values, and any deviations. This gives buyers and quality managers the information needed to compare tests and trace the conditions used.

What terms does ISO 5013 define?

ISO 5013 defines the main terms needed to read and perform the test consistently.

  • Modulus of rupture (MOR) - the maximum stress a prismatic test piece can withstand in three-point bending before failure.
  • Test temperature - the temperature measured at the mid-point of the tensile face of the test piece.
  • Three-point bending - a bending arrangement with support bearings near the ends and a central load applied between them.
  • Dense shaped refractory product - a shaped refractory product with true porosity below the specified limit when measured by ISO 5017.
  • Shaped insulating refractory - a shaped refractory product with true porosity at or above the specified limit when measured by ISO 5016.
  • Sample - a representative collection of items taken under an agreed sampling plan.
  • Item - a refractory brick or shape.
  • Test piece - a specimen extracted from an item and prepared for the test.

Who uses ISO 5013?

ISO 5013 is used by refractory manufacturers, testing laboratories, and parties who buy or specify refractory products. It is relevant when product performance has to be checked at elevated temperature rather than at room temperature.

It is also used by quality managers and technical buyers who need a common method for comparing hot bending strength across batches, product types, and laboratories. The reporting requirements help users track specimen history, atmosphere, heating, and loading conditions.

What changed in ISO 5013 from the previous edition?

ISO 5013 is the second edition and it cancels and replaces ISO 5013:1985. The document states three main changes: revised definitions, a recommendation for lower HMOR values to use a stress rate of 0.05 MPa/s, and the addition of an informative annex on precision and bias plus comparison of different test methods for C-containing materials.

Which standards are used with ISO 5013?

ISO 5013 relies on the following standards and related parts.

StandardContribution
ISO 1893Used to define the temperature limit linked to maximal expansion H
ISO 13385-1Gives the calliper requirements for measuring specimen dimensions
ISO 7500-1Sets the calibration and verification requirements for the testing machine force measurement system
ISO 5014Gives the ambient-temperature method for modulus of rupture
ISO 1927-5Gives preparation and treatment of test pieces for monolithic refractories
ISO 1927-6Supports applicability to unshaped refractories
ISO 5017Used for true porosity measurement in the definition of dense shaped refractory product
ISO 5016Used for true porosity measurement in the definition of shaped insulating refractory
ISO 5022Gives sampling and acceptance testing, including an example sampling plan
ISO 5725-2Used for the repeatability and reproducibility treatment in Annex B

What does the ISO 5013 document contain?

ISO 5013 contains a full laboratory method, including the test principle, apparatus requirements, specimen preparation rules, and the step-by-step heating and loading procedure. It also includes a formula for calculating modulus of rupture and a reporting checklist for the final test report.

The document includes Figure 1 for the test jig arrangement, Figure 2 for extraction from larger items, Table 1 for test-piece dimensions and tolerances, and Table 2 for standard loading rates. Annex A gives the temperature-uniformity check and furnace-to-specimen temperature relation, while Annex B gives precision statistics from an interlaboratory study.

Relations

Effective Date
07-Jan-2025

Buy Documents

Draft

ISO/FDIS 5013 - Refractory products — Determination of modulus of rupture at elevated temperatures

Release Date:07-Sep-2026
English language (13 pages)
sale 15% off
sale 15% off
Draft

REDLINE ISO/FDIS 5013 - Refractory products — Determination of modulus of rupture at elevated temperatures

Release Date:07-Sep-2026
English language (13 pages)
sale 15% off
sale 15% off

Frequently Asked Questions

ISO 5013 is a draft published by the International Organization for Standardization (ISO). Its full title is "Refractory products — Determination of modulus of rupture at elevated temperatures". This standard covers: Specifies a method for the determination of the refractory products at elevated temperatures, under conditions of a constant rate of increase of stress. A method for determination of the same property at ambient temperature is given in ISO 5014. The modulus of rupture is the ratio of the bending moment at the point of failure to the moment of resistance (the section modulus). It is calculated from an equation which is derived from Hooke' s Law for elastic materials.

Specifies a method for the determination of the refractory products at elevated temperatures, under conditions of a constant rate of increase of stress. A method for determination of the same property at ambient temperature is given in ISO 5014. The modulus of rupture is the ratio of the bending moment at the point of failure to the moment of resistance (the section modulus). It is calculated from an equation which is derived from Hooke' s Law for elastic materials.

ISO 5013 is classified under the following ICS (International Classification for Standards) categories: 81.080 - Refractories. The ICS classification helps identify the subject area and facilitates finding related standards.

ISO 5013 has the following relationships with other standards: It is inter standard links to ISO 5013:1985. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.

ISO 5013 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.

Standards Content (Sample)


FINAL DRAFT
International
Standard
ISO/FDIS 5013
ISO/TC 33
Refractory products —
Secretariat: BSI
Determination of modulus of
Voting begins on:
rupture at elevated temperatures
2026-09-21
Produits réfractaires — Détermination du module de rupture par
Voting terminates on:
flexion à températures élevées
2026-11-16
RECIPIENTS OF THIS DRAFT ARE INVITED TO SUBMIT,
WITH THEIR COMMENTS, NOTIFICATION OF ANY
RELEVANT PATENT RIGHTS OF WHICH THEY ARE AWARE
AND TO PROVIDE SUPPOR TING DOCUMENTATION.
IN ADDITION TO THEIR EVALUATION AS
BEING ACCEPTABLE FOR INDUSTRIAL, TECHNO­
LOGICAL, COMMERCIAL AND USER PURPOSES, DRAFT
INTERNATIONAL STANDARDS MAY ON OCCASION HAVE
TO BE CONSIDERED IN THE LIGHT OF THEIR POTENTIAL
TO BECOME STAN DARDS TO WHICH REFERENCE MAY BE
MADE IN NATIONAL REGULATIONS.
Reference number
ISO/FDIS 5013:2026(en) © ISO 2026

FINAL DRAFT
ISO/FDIS 5013:2026(en)
International
Standard
ISO/FDIS 5013
ISO/TC 33
Refractory products —
Secretariat: BSI
Determination of modulus of
Voting begins on:
rupture at elevated temperatures
Produits réfractaires — Détermination du module de rupture par
Voting terminates on:
flexion à températures élevées
RECIPIENTS OF THIS DRAFT ARE INVITED TO SUBMIT,
WITH THEIR COMMENTS, NOTIFICATION OF ANY
RELEVANT PATENT RIGHTS OF WHICH THEY ARE AWARE
AND TO PROVIDE SUPPOR TING DOCUMENTATION.
© ISO 2026
IN ADDITION TO THEIR EVALUATION AS
All rights reserved. Unless otherwise specified, or required in the context of its implementation, no part of this publication may
BEING ACCEPTABLE FOR INDUSTRIAL, TECHNO­
LOGICAL, COMMERCIAL AND USER PURPOSES, DRAFT
be reproduced or utilized otherwise in any form or by any means, electronic or mechanical, including photocopying, or posting on
INTERNATIONAL STANDARDS MAY ON OCCASION HAVE
the internet or an intranet, without prior written permission. Permission can be requested from either ISO at the address below
TO BE CONSIDERED IN THE LIGHT OF THEIR POTENTIAL
or ISO’s member body in the country of the requester.
TO BECOME STAN DARDS TO WHICH REFERENCE MAY BE
MADE IN NATIONAL REGULATIONS.
ISO copyright office
CP 401 • Ch. de Blandonnet 8
CH-1214 Vernier, Geneva
Phone: +41 22 749 01 11
Email: copyright@iso.org
Website: www.iso.org
Published in Switzerland Reference number
ISO/FDIS 5013:2026(en) © ISO 2026

ii
ISO/FDIS 5013:2026(en)
Contents Page
Foreword .iv
1 Scope . 1
2 Normative references . 1
3 Terms and definitions . 1
4 Principle . 2
5 Apparatus . 2
6 Number, shape, size and preparation of test pieces . 4
6.1 Number of test pieces .4
6.2 Shape and size .4
6.3 Preparation .5
7 Procedure . 6
7.1 Measuring test pieces, checking test jig, positioning test piece .6
7.2 Heating.6
7.3 Loading .6
8 Expression of results . 7
9 Test report . 7
Annex A (normative) Measurement of temperature distribution in the test piece . 9
Annex B (informative) Precision and bias . 10
Bibliography .13

iii
ISO/FDIS 5013:2026(en)
Foreword
ISO (the International Organization for Standardization) is a worldwide federation of national standards
bodies (ISO member bodies). The work of preparing International Standards is normally carried out through
ISO technical committees. Each member body interested in a subject for which a technical committee
has been established has the right to be represented on that committee. International organizations,
governmental and non-governmental, in liaison with ISO, also take part in the work. ISO collaborates closely
with the International Electrotechnical Commission (IEC) on all matters of electrotechnical standardization.
The procedures used to develop this document and those intended for its further maintenance are described
in the ISO/IEC Directives, Part 1. In particular, the different approval criteria needed for the different types
of ISO document should be noted. This document was drafted in accordance with the editorial rules of the
ISO/IEC Directives, Part 2 (see www.iso.org/directives).
ISO draws attention to the possibility that the implementation of this document may involve the use of (a)
patent(s). ISO takes no position concerning the evidence, validity or applicability of any claimed patent
rights in respect thereof. As of the date of publication of this document, ISO had not received notice of (a)
patent(s) which may be required to implement this document. However, implementers are cautioned that
this may not represent the latest information, which may be obtained from the patent database available at
www.iso.org/patents. ISO shall not be held responsible for identifying any or all such patent rights.
Any trade name used in this document is information given for the convenience of users and does not
constitute an endorsement.
For an explanation of the voluntary nature of standards, the meaning of ISO specific terms and expressions
related to conformity assessment, as well as information about ISO's adherence to the World Trade
Organization (WTO) principles in the Technical Barriers to Trade (TBT), see www.iso.org/iso/foreword.html.
This document was prepared by Technical Committee ISO/TC 33, Refractories.
This second edition cancels and replaces the first edition (ISO 5013:1985), which has been technically
revised.
The main changes are as follows:
— revised definitions;
— recommendation for lower HMOR values change to a stress rate of 0,05 MPa/s;
— addition of an informative annex on precision and bias and comparison of different test methods for
C-containing materials.
Any feedback or questions on this document should be directed to the user’s national standards body. A
complete listing of these bodies can be found at www.iso.org/members.html.

iv
FINAL DRAFT International Standard ISO/FDIS 5013:2026(en)
Refractory products — Determination of modulus of rupture
at elevated temperatures
1 Scope
This document specifies a method for the determination of the modulus of rupture of dense and insulating
shaped refractory products at elevated temperatures, under conditions of a constant rate of increase of
stress.
NOTE A method for determination of the modulus of rupture at ambient temperature is given in ISO 5014.
Shaped refractories are those which have fixed geometry and dimensions when delivered to the user. This
document is applicable to standard shape refractory bricks, but also special shapes of refractory products
and pre-cast products. This document is also applicable to unshaped refractories (see ISO 1927-6) after
preparation of test specimens according to ISO 1927-5.
2 Normative references
The following documents are referred to in the text in such a way that some or all of their content constitutes
requirements of this document. For dated references, only the edition cited applies. For undated references,
the latest edition of the referenced document (including any amendments) applies.
ISO 1893, Refractory products — Determination of refractoriness under load — Differential method with rising
temperature
ISO 13385-1, Geometrical product specifications (GPS) — Dimensional measuring equipment — Part 1: Design
and metrological characteristics of callipers
ISO 7500-1, Metallic materials — Calibration and verification of static uniaxial testing machines — Part 1:
Tension/compression testing machines — Calibration and verification of the force-measuring system
3 Terms and definitions
For the purposes of this document, the following terms and definitions apply.
ISO and IEC maintain terminology databases for use in standardization at the following addresses:
— ISO Online browsing platform: available at https:// www .iso .org/ obp
— IEC Electropedia: available at https:// www .electropedia .org/
3.1
modulus of rupture
MOR
σ
F
maximum stress that a prismatic test piece of specified dimensions can withstand when it is bent in a three-
point bending device
3.2
test temperature
temperature at the mid-point of the tensile face of the test piece

ISO/FDIS 5013:2026(en)
3.3
three-point bending
means of bending a beam test piece whereby the test piece is supported on bearings near its ends, and a
central force is applied
3.4
dense shaped refractory product
product with specific dimensions, having a true porosity of less than 45 % by volume, when measured in
accordance with ISO 5017
3.5
shaped insulating refractory
shaped refractory having a true porosity of not less than 45 % by volume, when measured in accordance
with ISO 5016
3.6
sample
representative collection of items that can be obtained by sampling according to a sampling plan agreed
upon by the interested parties
Note 1 to entry: An example of applicable sampling plan is given in ISO 5022.
3.7
item
refractory brick or shape
3.8
test piece
test specimen
piece of material extracted from an item (3.7) and suitably shaped and prepared for the test
4 Principle
Test pieces taken from items (bricks) are heated to the test temperature under controlled atmosphere. After
being maintained at this temperature until a uniform temperature is reached, the test pieces are loaded at a
constant rate of increase of tensile stress until failure occurs.
5 Apparatus
5.1 Test jig
The loading device shall have two bearing edges to support the test piece and one for the application of the
load. The three bearing edges shall be parallel to each other. For normal test pieces, the distance between the
bearing edges supporting the test piece shall be 125 mm ± 2 mm, with proportionate separations for other
test piece lengths (see 6.2). The loading bearing edge shall be placed centrally between the two supporting
bearing edges with an accuracy of ±2 mm (see the figure 1).
The bearing edges and test pieces shall be free from any reaction on contact at the test temperature.
The bearing edges shall have a length not less than 5 mm greater than the width of the test pieces and a
radius of curvature of 5 mm ± 1 mm.
Since the bearing edges become flattened with use, they shall be examined periodically to ensure that their
radii remain within these limits.
The distance between the two supporting bearing edges (see the figure) shall be measured at room
temperature to an accuracy of ±0,5 mm (this value is used in the calculation of the modulus of rupture).

ISO/FDIS 5013:2026(en)
5.2 Testing machine
Capable of applying a force uniformly to the loading roller in order to stress the test piece. The machine
shall be capable of applying this force at a constant loading rate. The test machine shall be equipped for
recording the peak load applied to the test piece. The accuracy of the test machine shall be in accordance
with ISO 7500-1, Grade 2 (accuracy 2 % of indicated load), or better.
5.3 Furnace
5.3.1 The furnace shall be one of the following types:
a) batch type, in which a number of test pieces are heated to the test temperature together and tested in
turn;
b) sequential type, in which the test pieces are heated to the test temperature one after another as they
pass through the apparatus.
5.3.2 ln either case, the furnace shall be capable of providing the overall heating of both the test jig and the
test pieces, and shall be so designed that at the moment of test, the temperature distribution in the test piece
is uniform within ±10 °C.
5.3.3 The atmosphere in the furnace shall be one of the following, as agreed between the parties
concerned in the test: air, some other specified gas, or the specimen shall be covered with graphite (or fine
metallurgical coke) in a box with a lid.
5.4 Temperature measuring device
5.4.1 The test temperature (3.2) shall be measured by a calibrated thermocouple placed at a maximal
distance of 20 mm from the midpoint of the tensile face of the test piece.
5.4.2 The relationship between this test temperature and the furnace temperature shall first be
established and shall be checked periodically in accordance with the procedure set out in Annex A.
5.4.3 During the test, the furnace shall be maintained at such a temperature that the midpoint of the
tensile face of the test piece is nominally at the required test temperature.
5.5 Drying oven, capable of being controlled at (110 ± 5) °C, or other device which has an equivalent
heating effect.
For MgO-containing products, it is recommended to dry the test pieces to constant mass at (150 ± 10) °C.
NOTE A fan-assisted oven with ventilation and an exhaust air damper would assist in attaining an even
temperature distribution and efficient drying of the test pieces.
5.6 Calliper, which shall be in accordance with ISO 13385-1, of resolution 0,1 mm, or alternative calibrated
device measuring to this resolution, for measurement of test piece dimensions.

ISO/FDIS 5013:2026(en)
Key
1 loading bearing edge
2 compression face
3 supporting bearing edges
4 tensile face (not an original face of the item)
L span, distance between the points of support of the test piece
s
h height of the test piece
Figure 1 — Arrangements and dimensions of test piece and bearing edges of the test jig; for
tolerances, see Table 1
6 Number, shape, size and preparation of test pieces
6.1 Number of test pieces
6.1.1 A sample consists of at least four items, obtained by sampling according to a sampling plan agreed
upon by the interested parties, e.g. ISO 5022.
6.1.2 The number of test pieces to be tested for each item (brick) at each test temperature shall be agreed
between the interested parties and shall be the same for each item; it shall be stated in the test report.
If only one item is available, whenever possible, at least four test pieces will be taken in order to compose a
representative sample.
6.2 Shape and size
6.2.1 Unless otherwise agreed, the test piece shall be a rectangular bar with a cross-section of
25 mm ± 1 mm x 25 mm ± 1 mm and a length of about 150 mm. The longitudinal faces of each test piece shall
be parallel to each other within a tolerance of ±0,2 mm and the si
...


ISO/FDIS 5013:2026(en)
ISO/TC 33
Secretariat: BSI
Date: 2026-09-07-08
Refractory products - — Determination of modulus of rupture at
elevated temperatures
Produits réfractaires — Détermination du module de rupture par flexion à températures élevées
FDIS stage
ISO/FDIS 5013:2026(en)
All rights reserved. Unless otherwise specified, or required in the context of its implementation, no part of this publication
may be reproduced or utilized otherwise in any form or by any means, electronic or mechanical, including photocopying,
or posting on the internet or an intranet, without prior written permission. Permission can be requested from either ISO
at the address below or ISO’s member body in the country of the requester.
ISO copyright office
CP 401 • Ch. de Blandonnet 8
CH-1214 Vernier, Geneva
Phone: + 41 22 749 01 11
EmailE-mail: copyright@iso.org
Website: www.iso.orgwww.iso.org
Published in Switzerland
ii © ISO 2025 2026 – All rights reserved
ii
ISO/FDIS 5013:2026(en)
Contents
Foreword . v
1 Scope . 1
2 Normative references . 1
3 Terms and definitions . 1
4 Principle . 2
5 Apparatus . 2
6 Number, shape, size and preparation of test pieces . 4
6.1 Number of test pieces . 4
6.2 Shape and size . 4
6.3 Preparation . 5
7 Procedure . 6
7.1 Measuring test pieces, checking test jig, positioning test piece . 6
7.2 Heating . 6
7.3 Loading . 6
8 Expression of results . 7
9 Test report . 8
Annex A (normative) Measurement of temperature distribution in the test piece . 9
Annex B (informative) Precision and bias . 10
Bibliography . 14

Foreword . iv
Introduction . v
1 Scope . 1
2 Normative references . 1
3 Terms and definitions . 1
3.1 modulus of rupture . 1
3.2 test temperature . 2
3.3 three-point bending . 2
3.4 sample . 2
3.5 item . 2
3.6 test piece . 2
4 Principle . 2
5 Apparatus . 2
5.1 Test jig . 2
5.2 Testing machine . 2
5.3 Furnace . 3
6 Number, shape, size and preparation of test pieces . 4
6.1 Number of test pieces . 4
6.2 Shape and size . 4
6.3 Preparation . 5
7 Procedure . 5
7.1 Measuring test pieces, checking test jig, positioning test piece . 5
iii
ISO/FDIS 5013:2026(en)
7.2 Heating . 6
7.3 Loading . 6
8 Expression of results . 7
9 Test report . 7
Annex A . 9
Annex B . 10
Bibliography . 14
iv © ISO 2025 2026 – All rights reserved
iv
ISO/FDIS 5013:2026(en)
Foreword
ISO (the International Organization for Standardization) is a worldwide federation of national standards
bodies (ISO member bodies). The work of preparing International Standards is normally carried out through
ISO technical committees. Each member body interested in a subject for which a technical committee has been
established has the right to be represented on that committee. International organizations, governmental and
non-governmental, in liaison with ISO, also take part in the work. ISO collaborates closely with the
International Electrotechnical Commission (IEC) on all matters of electrotechnical standardization.
The procedures used to develop this document and those intended for its further maintenance are described
in the ISO/IEC Directives, Part 1. In particular, the different approval criteria needed for the different types of
ISO document should be noted. This document was drafted in accordance with the editorial rules of the
ISO/IEC Directives, Part 2 (see www.iso.org/directives).
ISO draws attention to the possibility that the implementation of this document may involve the use of (a)
patent(s). ISO takes no position concerning the evidence, validity or applicability of any claimed patent rights
in respect thereof. As of the date of publication of this document, ISO had not received notice of (a) patent(s)
which may be required to implement this document. However, implementers are cautioned that this may not
represent the latest information, which may be obtained from the patent database available at
www.iso.org/patents.www.iso.org/patents. ISO shall not be held responsible for identifying any or all such
patent rights.
Any trade name used in this document is information given for the convenience of users and does not
constitute an endorsement.
For an explanation of the voluntary nature of standards, the meaning of ISO specific terms and expressions
related to conformity assessment, as well as information about ISO's adherence to the World Trade
Organization (WTO) principles in the Technical Barriers to Trade (TBT), see
www.iso.org/iso/foreword.htmlwww.iso.org/iso/foreword.html.
This document was prepared by Technical Committee ISO/TC 33, Refractories.
This second edition cancels and replaces the first edition (ISO 5013:1985), which has been technically revised.
The main changes are as follows:
— — revised definitions;
— — recommendation for lower HMOR values change to a stress rate of 0,05 MPa/s;
— — addition of an informative annex on precision and bias and comparison of different test methods for
C-containing materials.
Any feedback or questions on this document should be directed to the user’s national standards body. A
complete listing of these bodies can be found at www.iso.org/members.htmlwww.iso.org/members.html.
v
FINAL DRAFT International Standard ISO/FDIS 5013:2026(en)

Refractory products - — Determination of modulus of rupture at
elevated temperatures
1 Scope
This document specifies a method for the determination of the modulus of rupture of dense and insulating
shaped refractory products at elevated temperatures, under conditions of a constant rate of increase of stress.
NOTE A method for determination of the modulus of rupture at ambient temperature is given in ISO 5014.
Shaped refractories are those which have fixed geometry and dimensions when delivered to the user. This
document is applicable to standard shape refractory bricks, but also special shapes of refractory products and
pre-cast products. This document is also applicable to unshaped refractories (see ISO 1927-6) after
preparation of test specimens according to ISO 1927-5.
2 Normative references
The following documents are referred to in the text in such a way that some or all of their content constitutes
requirements of this document. For dated references, only the edition cited applies. For undated references,
the latest edition of the referenced document (including any amendments) applies.
ISO 1893, Refractory products — Determination of refractoriness under load — Differential method with
rising temperature
ISO 13385-ISO 1893, Refractory products — Determination of refractoriness under load — Differential
method with rising temperature
ISO 13385-1, Geometrical product specifications (GPS) — Dimensional measuring equipment — Part 1: Design
and metrological characteristics of callipers
ISO 7500-ISO 7500-1, Metallic materials — Calibration and verification of static uniaxial testing machines
— Part 1: Tension/compression testing machines — Calibration and verification of the force-measuring
system
3 Terms and definitions
For the purposes of this document, the following terms and definitions apply.
ISO and IEC maintain terminology databases for use in standardization at the following addresses:
— — ISO Online browsing platform: available at https://www.iso.org/obphttps://www.iso.org/obp
— — IEC Electropedia: available at https://www.electropedia.org/https://www.electropedia.org/
3.1 3.1
modulus of rupture
MOR
σ
F
maximum stress that a prismatic test piece of specified dimensions can withstand when it is bent in a three-
point bending device
ISO/FDIS 5013:2026(en)
3.2 3.2
test temperature
temperature at the mid-point of the tensile face of the test piece
3.3 3.3
three-point bending
means of bending a beam test piece whereby the test piece is supported on bearings near its ends, and a central
force is applied
3.4 3.4
dense shaped refractory product
product with specific dimensions, having a true porosity of less than 45 % by volume, when measured in
accordance with ISO 5017
3.5 3.5
shaped insulating refractory
shaped refractory having a true porosity of not less than 45 % by volume, when measured in accordance with
ISO 5016
3.6 3.6
sample
representative collection of items that can be obtained by sampling according to a sampling plan agreed upon
by the interested parties
Note 1 to entry: An example of applicable sampling plan is given in ISO 5022.
3.7 3.7
item
refractory brick or shape
3.8 3.8
test piece
test specimen
piece of material extracted from an item (3.5)(3.7) and suitably shaped and prepared for the test
4 Principle
Test pieces taken from items (bricks) are heated to the test temperature under controlled atmosphere. After
being maintained at this temperature until a uniform temperature is reached, the test pieces are loaded at a
constant rate of increase of tensile stress until failure occurs.
5 Apparatus
5.1 5.1 Test jig
The loading device shall have two bearing edges to support the test piece and one for the application of the
load. The three bearing edges shall be parallel to each other. For normal test pieces, the distance between the
bearing edges supporting the test piece shall be 125 mm ± 2 mm, with proportionate separations for other
test piece lengths (see 6.2).6.2). The loading bearing edge shall be placed centrally between the two supporting
bearing edges with an accuracy of ±2 mm (see the figure 1).Figure 1 ).
The bearing edges and test pieces shall be free from any reaction on contact at the test temperature.
The bearing edges shall have a length not less than 5 mm greater than the width of the test pieces and a radius
of curvature of 5 mm ± 1 mm.
2 © ISO 2025 2026 – All rights reserved
ISO/FDIS 5013:2026(en)
Since the bearing edges become flattened with use, they shall be examined periodically to ensure that their
radii remain within these limits.
The distance between the two supporting bearing edges (see the figure) shall be measured at room
temperature to an accuracy of ±0,5 mm (this value is used in the calculation of the modulus of rupture).
5.2 5.2 Testing machine
Capable of applying a force uniformly to the loading roller in order to stress the test piece. The machine shall
be capable of applying this force at a constant loading rate. The test machine shall be equipped for recording
the peak load applied to the test piece. The accuracy of the test machine shall be in accordance with ISO 7500-
1, Grade 2 (accuracy 2 % of indicated load), or better.
5.3 5.3 Furnace
5.3.1 5.3.1 The furnace shall be one of the following types:
a) a) batch type, in which a number of test pieces are heated to the test temperature together and
tested in turn;
b) b) sequential type, in which the test pieces are heated to the test temperature one after another
as they pass through the apparatus.
5.3.2 5.3.2 ln either case, the furnace shall be capable of providing the overall heating of both the test jig
and the test pieces, and shall be so designed that at the moment of test, the temperature distribution
in the test piece is uniform within ±10 °C.
5.3.3 5.3.3 The atmosphere in the furnace shall be one of the following, as agreed between the parties
concerned in the test;: air, some other specified gas, or the specimen shall be covered with graphite
(or fine metallurgical coke) in a box with a lid.
5.4 5.4 Temperature measuring device
5.4.1 5.4.1 The test temperature (3.2)(3.2) shall be measured by a calibrated thermocouple placed at a
maximal distance of 20 mm from the midpoint of the tensile face of the test piece.
5.4.2 5.4.2 The relationship between this test temperature and the furnace temperature shall first be
established and shall be checked periodically in accordance with the procedure set out in
Annex A.Annex A.
5.4.3 5.4.3 During the test, the furnace shall be maintained at such a temperature that the midpoint of the
tensile face of the test piece is nominally at the required test temperature.
5.5 5.5 Drying oven, capable of being controlled at (110 ± 5) °C, or other device which has an
equivalent heating effect.
For MgO-containing products, it is recommended to dry the test pieces to constant mass at (150 ± 10) °C.
NOTE A fan-assisted oven with ventilation and an exhaust air damper would assist in attaining an even temperature
distribution and efficient drying of the test pieces.
5.6 5.6 Calliper, which shall be in accordance with ISO 13385-1, of resolution 0,1 mm, or alternative
calibrated device measuring to this resolution, for measurement of test piece dimensions.

ISO/FDIS 5013:2026(en)
5013_ed2fig1.EPS
Key
1 loading bearing edge
2 compression face
3 supporting bearing edges
4 tensile face (not an original face of the item)
Ls span, distance between the points of support of the test piece
h height of the test piece
Figure 1 — Arrangements and dimensions of test piece and bearing edges of the test jig; for
tolerances, see Table 1Table 1
6 Number, shape, size and preparation of test pieces
6.1 Number of test pieces
6.1.1 6.1.1 A sample consists of at least four items, obtained by sampling according to a sampling plan
agreed upon b
...