INTERNATIONAL STANDARD 2470
INTERNATIONAL ORGANIZATION FOR STANDARDlZATlON 44EX~YHAPO~HAR OPrAHMJAUMfi IlO CTAHlIAPTM3ALVfl-l .ORGANISATION INTERNATIONALE DE NORMALISATION
Paper and board - Measurement of diffuse blue reflectance
factor (IS0 brightness)
Papier et carton
-” Mesurage du facteur de r4flectance diffuse dans le bleu (degrk de blancheur /SO)
Second edition .- 1977-02-15
UDC 676.017
Ref. No. IS0 2470-1977 (E)
Descriptors : paper, paperboards, tests, optical tests, reflectance, IS0 brightness.
Price based on 4 pages
---------------------- Page: 1 ----------------------
IS0 (the International Organization for Standardization) is a worldwide federation
of national standards institutes (IS0 member bodies). The work of developing
International Standards is carried out through IS0 technical committees. Every
member body interested in a subject for which a technicalcommittee has been set
up has the right to be represented on that committee. International organizations,
governmental and non-governmental, in liaison with ISO, also take part in the work.
Draft International Standards adopted by the technical committees are circulated
to the member bodies for approval before their acceptance as International
Standards by the IS0 Council.
International Standard IS0 2470 was developed by Thnical Committee
lSO/TC 6, Paper, board and pulps, and circulated to the member bodies in
September 1971.
It has been approved by the member bodies of the following countries :
South Africa, Rep. of
Australia India
Spain
Austria Iran
Ireland Sweden
Belgium
Switzerland
Bulgaria Israel
Thailand
Canada Italy
Czechoslovakia Netherlands Turkey
United Kingdom
Egypt, Arab Rep. of New Zealand
U.S.A.
Finland Norway
Poland U.S.S.R.
France
Germany Portugal
Romania
Hungary
No member body expressed disapproval of the document.
This second edition, incorporating an annex which was submitted directly to the
IS0 Council in accordance with clause 6.12.1 of the Directives for the technical
work of ISO, cancels and replaces the first edition (IS0 2470-l 973).
0 Intwnrtionrl Ofgmization for Standrfdizdon, 1977 l
Printed in Switzerland
---------------------- Page: 2 ----------------------
INTERNATIONAL STANDARD Iso 2470-1977 (E)
Measurement of diffuse blue reflectance
Paper and board - .
factor (IS0 brightness)
0 INTRODUCTION 3 APPARATUS
The reflectance factor depends on the conditions of
3.1 Reflectometer,
in calibration with the reference
measurement, particularly the spectral and geometric
instrument described in IS0 2469, and equipped for the
characteristics of the instrument used. This International
measurement of blue reflectance factor.
Standard should be read in conjunction with IS0 2469,
Paper, board and pulps - Measurement of diffuse
re flee tance fat tof.
3.2 Filter that in conjunction with the spectraI
characteristics of the basic instrument gives an overall
effective wavelength of 457 + 0,5 nm and a bandwidth at
1 SCOPE AND FIELD OF APPLICATION
half-height of 44 nm.
This International Standard specifies a method for
diffuse factor
measuring the blue reflectance
3.3 Two working standards calibrated against IS0
(IS0 brightness) of paper and board.
reference standards of level 3 supplied by the authorized
This International Standard is confined in its scope to white
laboratory for blue reflectance factor standardization
and near-white papers and boards. Paper or board that has
purposes.
been treated with a fluorescent dyestuff or exhibits
Details of the calibration of the working standards together
signif icant fluorescence may be measured, but the
with cleaning precautions and use are given in IS0 2469.
agreement between values obtained with different
Calibrate the working standards by using IS0 reference
instruments may be unsatisfactory and there may be
standards of level 3. In each case recently calibrated
difficulty in assessing the meaning of results.
reference standards intended for the calibration of the
NOTE - Two reflectometers of different makes may both have
reflectance factor
instrument for diffuse blue
spectral characteristics giving an effective wavelength of 457 nm
(IS0 brightness) of paper and board measurements shall be
although the spectral power distributions of the radiation incident
are different. If this difference occurs in the spectral region that
used at suitable intervals to ensure agreement with the
excites fluorescent radiation and if this fluorescent radiation is
reference instrument.
emitted in the spectral region of the measurements (near 450 nm),
then different values of brightness can be obtained. Hence,
measurements can only be made satisfactorily on samples exhibiting
fluorescence if the spectral power distribution of the irradiation in
the long wave ultra-violet region is standardized.
4 SAMPLING
The sampling procedure wiil differ according to the
2 DEFINITIONS
purposes for which the measurement is required. It shall be
agreed between the parties concerned.
For the purpose of this International Standard the
following definitions apply :
2.1 reflectance factor, R : The ratio, expressed as a
I
5 PREPARATION OF TEST PIECES
percentage, of the radiation reflected by a body to that
reflected by a perfect reflecting diffuser under the same
Avoiding watermarks, dirt and obvious defects of the paper,
conditions.
cut rectangular about 75 mm x 150 mm.
test pieces
Assemble not less than ten test pieces top side upwards in a
2.2 intrinsic reflectance factor, R, : The reflectance
pad using, if necessary, a number greater than ten so that
factor of a layer or pad of the material thick enough to be
the blue reflectance factor remains unchanged if the .
opaque.
number is increased. Protect the pad by placing an
additional test piece on both top and bottom; avoid
2.3 diffuse blue reflectance factor (IS0 brightness) : The
contamination and unnecessary exposure to light or heat.
intrinsic reflectance factor measured at an effective
wavelength of 457 nm with a reflectometer having specified
Mark the top test piece in one corner to identify the sample
characteristics as given in IS0 2469. and the top side.
1
---------------------- Page: 3 ----------------------
IS0 24704977 (E)
6 PROCEDURE (ISC brightness) of the paper or board in per cent to the
nearest 0,5 % reflectance factor.
Check that the correct filters are in the light beams.
from
Remove the protecting sheets the test piece pad.
touching the test area, use the procedure
Without
appropriate to the instrument, and the working standard, to
measure the intrinsic reflectance factor of the top side of
8 TEST REPORT
the test piece pad. Read and record the value to the nearest
The test report shall include the following details :
0,l % reflectance factor. Move the uppermost test piece to
the bottom of the pad and determine the b
...
SLOVENSKI STANDARD
SIST ISO 2470:1995
01-junij-1995
Papir, karton in lepenka - Merjenje faktorja razpršene odsevnosti v modrem (belina
po ISO)
Paper and board -- Measurement of diffuse blue reflectance factor (ISO brightness)
Papier et carton -- Mesurage du facteur de réflectance diffuse dans le bleu (degré de
blancheur ISO)
Ta slovenski standard je istoveten z: ISO 2470:1977
ICS:
85.040 Vlaknine Pulps
85.060 Papir, karton in lepenka Paper and board
SIST ISO 2470:1995 en
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
---------------------- Page: 1 ----------------------
SIST ISO 2470:1995
---------------------- Page: 2 ----------------------
SIST ISO 2470:1995
INTERNATIONAL STANDARD 2470
INTERNATIONAL ORGANIZATION FOR STANDARDlZATlON 44EX~YHAPO~HAR OPrAHMJAUMfi IlO CTAHlIAPTM3ALVfl-l .ORGANISATION INTERNATIONALE DE NORMALISATION
Paper and board - Measurement of diffuse blue reflectance
factor (IS0 brightness)
Papier et carton
-” Mesurage du facteur de r4flectance diffuse dans le bleu (degrk de blancheur /SO)
Second edition .- 1977-02-15
UDC 676.017
Ref. No. IS0 2470-1977 (E)
Descriptors : paper, paperboards, tests, optical tests, reflectance, IS0 brightness.
Price based on 4 pages
---------------------- Page: 3 ----------------------
SIST ISO 2470:1995
IS0 (the International Organization for Standardization) is a worldwide federation
of national standards institutes (IS0 member bodies). The work of developing
International Standards is carried out through IS0 technical committees. Every
member body interested in a subject for which a technicalcommittee has been set
up has the right to be represented on that committee. International organizations,
governmental and non-governmental, in liaison with ISO, also take part in the work.
Draft International Standards adopted by the technical committees are circulated
to the member bodies for approval before their acceptance as International
Standards by the IS0 Council.
International Standard IS0 2470 was developed by Thnical Committee
lSO/TC 6, Paper, board and pulps, and circulated to the member bodies in
September 1971.
It has been approved by the member bodies of the following countries :
South Africa, Rep. of
Australia India
Spain
Austria Iran
Ireland Sweden
Belgium
Switzerland
Bulgaria Israel
Thailand
Canada Italy
Czechoslovakia Netherlands Turkey
United Kingdom
Egypt, Arab Rep. of New Zealand
U.S.A.
Finland Norway
Poland U.S.S.R.
France
Germany Portugal
Romania
Hungary
No member body expressed disapproval of the document.
This second edition, incorporating an annex which was submitted directly to the
IS0 Council in accordance with clause 6.12.1 of the Directives for the technical
work of ISO, cancels and replaces the first edition (IS0 2470-l 973).
0 Intwnrtionrl Ofgmization for Standrfdizdon, 1977 l
Printed in Switzerland
---------------------- Page: 4 ----------------------
SIST ISO 2470:1995
INTERNATIONAL STANDARD Iso 2470-1977 (E)
Measurement of diffuse blue reflectance
Paper and board - .
factor (IS0 brightness)
0 INTRODUCTION 3 APPARATUS
The reflectance factor depends on the conditions of
3.1 Reflectometer,
in calibration with the reference
measurement, particularly the spectral and geometric
instrument described in IS0 2469, and equipped for the
characteristics of the instrument used. This International
measurement of blue reflectance factor.
Standard should be read in conjunction with IS0 2469,
Paper, board and pulps - Measurement of diffuse
re flee tance fat tof.
3.2 Filter that in conjunction with the spectraI
characteristics of the basic instrument gives an overall
effective wavelength of 457 + 0,5 nm and a bandwidth at
1 SCOPE AND FIELD OF APPLICATION
half-height of 44 nm.
This International Standard specifies a method for
diffuse factor
measuring the blue reflectance
3.3 Two working standards calibrated against IS0
(IS0 brightness) of paper and board.
reference standards of level 3 supplied by the authorized
This International Standard is confined in its scope to white
laboratory for blue reflectance factor standardization
and near-white papers and boards. Paper or board that has
purposes.
been treated with a fluorescent dyestuff or exhibits
Details of the calibration of the working standards together
signif icant fluorescence may be measured, but the
with cleaning precautions and use are given in IS0 2469.
agreement between values obtained with different
Calibrate the working standards by using IS0 reference
instruments may be unsatisfactory and there may be
standards of level 3. In each case recently calibrated
difficulty in assessing the meaning of results.
reference standards intended for the calibration of the
NOTE - Two reflectometers of different makes may both have
reflectance factor
instrument for diffuse blue
spectral characteristics giving an effective wavelength of 457 nm
(IS0 brightness) of paper and board measurements shall be
although the spectral power distributions of the radiation incident
are different. If this difference occurs in the spectral region that
used at suitable intervals to ensure agreement with the
excites fluorescent radiation and if this fluorescent radiation is
reference instrument.
emitted in the spectral region of the measurements (near 450 nm),
then different values of brightness can be obtained. Hence,
measurements can only be made satisfactorily on samples exhibiting
fluorescence if the spectral power distribution of the irradiation in
the long wave ultra-violet region is standardized.
4 SAMPLING
The sampling procedure wiil differ according to the
2 DEFINITIONS
purposes for which the measurement is required. It shall be
agreed between the parties concerned.
For the purpose of this International Standard the
following definitions apply :
2.1 reflectance factor, R : The ratio, expressed as a
I
5 PREPARATION OF TEST PIECES
percentage, of the radiation reflected by a body to that
reflected by a perfect reflecting diffuser under the same
Avoiding watermarks, dirt and obvious defects of the paper,
conditions.
cut rectangular about 75 mm x 150 mm.
test pieces
Assemble not less than ten test pieces top side upwards in a
2.2 intrinsic reflectance factor, R, : The reflectance
pad using, if necessary, a number greater than ten so that
factor of a layer or pad of the material thick enough to be
the blue reflectance factor remains unchanged if the .
opaque.
number is increased. Protect the pad by placing an
additional test piece on both top and bottom; avoid
2.3 diffuse blue reflectance factor (IS0 brightness) : The
contamination and unnecessary exposure to light or heat.
intrinsic reflectance factor measured at an effective
wavelength of 457 nm with a reflectometer having specified
Mark the top test piece in one corner to identify the sample
characteristics as given in IS0 2469. and the top side.
1
---------------------- Page: 5 ----------------------
SIST ISO 2470:1995
IS0 24704977 (E)
6 PROCEDURE (ISC brightness) of the paper or board in per cent to the
nearest 0,5 % reflectance factor.
Check that the correct filters are in the light beams.
from
Remove the protecting sheets the test piece pad.
touching the test area, u
...
NORME INTERNATIONALE
2470
~ ~~ ~~ ~
INTERNATIONAL ORGANIZATION FOR STANDARDIZATION *MEXLiYHAPOnHAR OPïAHIIJAULiR ii0 CTAHLIAPTLi3AUI.IH .ORGANISATION INTERNATIONALE DE NORMALISATION
L-
Papier et carton - Mesurage du facteur de réflectance diffuse
dans le bleu (degré de blancheur ISO)
Paper and board - Measurement of diffuse blue reflectance factor (IS0 brightness)
Deuxième édition - 1977-02-15
i
CDU 676.017 Réf. no : IS0 2470-1977 (FI
Descripteurs : papier, carton, essai, essai optique, réflectance, degré de blancheur IS0
F!
N
Prix basé sur 4 pages
s
---------------------- Page: 1 ----------------------
AVANT-PROPOS
L‘ISO (Organisation internationale de normalisation) est une fédération mondiale
d’organismes nationaux de normalisation (comités membres de I’ISO). L‘élaboration
des Normes internationales est confiée aux comités techniques de I’ISO. Chaque
comité membre intéressé par une étude a le droit de faire partiedu comité technique
correspondant. Les organisations internationales, gouvernementales et non
gouvernementales, en liaison avec I’ISO, participent également aux travaux.
Les projets de Normes internationales adoptés par les comités techniques sont
soumis aux comités membres pour approbation, avant leur acceptation comme
Normes internationales par le Conseil de I’ISO.
La Norme internationale IS0 2470 a été élaborée par le comité technique
lSO/TC6, Papiers, carrons er pâtes, et a été soumise aux comités membres en
septem bre 197 1 .
Les comités membres des pays suivants l‘ont approuvée :
Afrique du Sud, Rép. d’ Hongrie Roumanie
A I I emagne Inde Royaume-Uni
Australie Iran Suède
Autriche Ir lande Suisse
Belgique Israël Tchécoslovaquie
Bulgarie Italie Thaïlande
Canada Norvège Turquie
Egypte, Rép. arabe d’ Nouvelle-Zélande U.R.S.S.
Espagne Pays-Bas U.S.A.
Finlande Pologne
France Portuga I
le document.
Aucun comité membre n’a désapprouvé
La deuxième édition, incorporant une annexe qui a été soumise directement au
Conseil de I’ISO conformément au paragraphe 6.12.1 des Directives pour les
travaux techniques de I‘ISO, annule et remplace la première édition
(IS0 2470-1 973).
O Organisation internationale de normalisation, 1977 O
Imprimé en Suisse
---------------------- Page: 2 ----------------------
NORM E I NTE R NAT I ON ALE IS0 2470-1977 (F)
Papier et carton - Mesurage du facteur de réflectance diffuse
dans le bleu (degré de blancheur ISO)
O INTRODUCTION 3 APPAREILLAGE
La valeur du facteur de réflectance dépend des conditions
3.1 Réflectomètre, étalonné par rapport à l'appareil de
de son mesurage, en particulier des caractéristiques
référence décrit dans I'ISO 2469, et équipé pour le
spectrales et géométriques de l'appareil utilisé. La présente
mesurage du degré de blancheur.
Norme internationale doit être lue, par conséquent,
conjointement avec I'ISO 2469, Papier, cartons et pâtes -
Mesurage du facteur de réftectance diffuse.
3.2 Filtre, donnant, conjointement avec les carac-
téristiques spectrales de l'instrument, une longueur d'onde
effective de 457 f 0,5 nm et une largeur de bande à mi-
1 OBJET ET DOMAINE D'APPLICATION
hauteur de 44 nm.
La présente Norme internationale spécifie une méthode
de détermination du facteur de réflectance diffuse dans
le bleu du papier et du carton (degré de blancheur ISO). 3.3 Deux références de travail, étalonnées par rapport aux
IS0 de niveau 3 fournies par le laboratoire agréé
références
La présente Norme internationale est limitée aux papiers et
pour le mesurage du degré de blancheur.
cartons blancs ou presque blancs. Les papiers et cartons qui
ont été traités avec un colorant fluorescent ou qui montrent
Des détails sur l'étalonnage des références de travail, ainsi
une fluorescence nette peuvent etre évalués, mais la concor-
que les précautions de nettoyage et d'emploi, sont donnés
dance entre les valeurs obtenues avec différents appareils
dans I'ISO 2469. Étalonner les références de travail en
peut ne pas étre satisfaisant, et il peut y avoir des difficultés
IS0 de niveau 3. Dans tous les cas,
utilisant des références
pour interpréter les résultats.
des références IS0 de niveau 3 récentes, prévues pour
l'étalonnage de l'appareil en vue du mesurage du degré de
NOTE - Deux réflectometres de conception différente peuvent
blancheur, doivent être utilisées à des intervalles convena-
avoir des caractéristiques spectrales donnant a chacun une longueur
bles pour s'assurer de la concordance avec l'appareil de
d'onde effective de 457 nm, bien que les distributions spectrales du
référence.
rayonnement incident sur l'échantillon soient différentes. Si ces
différences concernent la région spectrale qui excite la fluorescence
de l'échantillon et SI le rayonnement de fluorescence concerne la
région spectrale de la mesure (au voisinage de 450 nm), on peut
alors obtenir des valeurs du degré de blancheur complètement
4 ÉCHANTILLONNAGE
différentes. Par conséquent, pour les échantillons fluorescents, on ne
peut faire de mesuLages satisfaisants que si la distribution spectrale
La procédure d'échantillonnage varie selon le but fixé aux
du rayonnement, dans le proche ultra-violet, est normalisée,
mesurages. Elle doit etre fixée par accord entre les parties
intéressées.
2 DÉFINITIONS
Dans le cadre de la présente Norme internationale, les
définitions suivantes sont applicables :
5 PRÉPARATION DES ÉPROUVETTES
2.1 facteur de réflectance, R : Rapport, exprimé en
pourcentage, du rayonnement réfléchi par un corps au Éviter les filigranes, les impuretés et défauts visibles du
rayonnement réfléchi dans les mêmes conditions par le papier. Couper des éprouvettes rectangulaires d'environ
75 mm x 150 mm. Assembler au moins dix éprouvettes
diffuseur parfait.
avec leur côté supérieur dirigé vers le haut, en constituant
2.2 facteur de réflectance intrinsèque, R, : Facteur de
une liasse qui aura, SI nécessaire, un nombre de feuilles
réflectance d'une couche de produit ou d'une liasse assez
supérieur à dix, afin que son degré de blancheur reste
épaisse pour être opaque.
inchangé si le nombre de feuilles est accru. Protéger la liasse
par des éprouvettes supplémentaires à la fois au-dessus et
2.3 facteur de réflectance diffuse dans le bleu (degré de
au-dessous de la liasse; éviter la contamination et
blancheur ISO) : Facteur de réflectance diffuse intrinsèque,
l'exposition non nécessaire à la lumière ou à la chaleur.
déterminé à la longueur d'onde effective de 457 nm avec un
les caractéristiques spécifiées dans Marquer l'éprouvette supérieure dans un coin pour
réflectomètre ayant
I'ISO 2469. identifier l'échantillon et le côté supérieur.
1
---------------------- Page: 3 ----------------------
IS0 2470-1977 (F)
réflectance diffuse dans le bleu (degré de blancheur ISO) du
6 MODE OPÉRATOIRE
papier ou du carton, en pourcentage, à 0,5 % de facteur de
S'assurer que les filtres convenables sont placés dans les
réf lectance près.
faisceaux de lumière. Enlever les feuilles protectrices de la
liasse d'éprouvettes. Sans toucher la surface d'essai avec les
doigts, mesurer le facteur de réflectance intrinsèque du côté
supérieur de la liasse d'éprouvettes, en utilisant un mode
8 PROCÈS-VERBAL D'ESSAI
d'emploi approprié à l'appareil et en se servant des
Le procès-verbal d'essai doit contenir les indications
références de travail. Lire et noter cette valeur à 0,l % de
suivantes :
facteur de réf lectance près. Enlever l'éprouvette supérieure
et la placer au bas de la liasse, puis déterminer le degré de
a) l'identification précise de l'échantillon;
blancheur de la deuxième éprouvette, et de même pour les
éprouvettes qui suivent, jusqu'à ce qu'un total d'au moins
b) la ré
...