Abstract

ISO 4355:2013 specifies methods for the determination of snow load on roofs. It can serve as a basis for the development of national codes for the determination of snow load on roofs. National codes should supply statistical data of the snow load on ground in the form of zone maps, tables, or formulae. The shape coefficients presented in ISO 4355:2013 are prepared for design application, and can thus be directly adopted for use in national codes, unless justification for other values is available. For determining the snow loads on roofs of unusual shapes or shapes not covered by ISO 4355:2013 or in national standards, it is advised that special studies be undertaken. These can include testing of scale models in a wind tunnel or water flume, especially equipped for reproducing accumulation phenomena, and should include methods of accounting for the local meteorological statistics. Examples of numerical methods, scale model studies, and accompanying statistical analysis methods are described in ISO 4355:2013 (Annex G). The annexes of ISO 4355:2013 describing methods for determining the characteristic snow load on the ground, exposure coefficient, thermal coefficient, and loads on snow fences are for information only as a consequence of the limited amount of documentation and available scientific results. In some regions, single winters with unusual weather conditions can cause severe load conditions not taken into account by ISO 4355:2013. Specification of standard procedures and instrumentation for measurements is not dealt with in ISo 4355:2013.

Status
Not Published
Current Stage
5020 - Proof sent to secretariat or FDIS ballot initiated: 8 weeks - 50 Approval
Start Date
11-Nov-2026
Due Date
11-Nov-2026
Completion Date
11-Nov-2026

Buy Documents

Draft

ISO/FDIS 4355 - Bases for design of structures — Determination of snow loads on roofs

Release Date:28-Oct-2026
English language (41 pages)
sale 15% off
sale 15% off
Draft

REDLINE ISO/FDIS 4355 - Bases for design of structures — Determination of snow loads on roofs

Release Date:28-Oct-2026
English language (41 pages)
sale 15% off
sale 15% off

ISO/FDIS 4355 is an ISO document for determining snow loads on roofs in structural design. It sets out methods for turning the characteristic snow load on the ground into roof snow loads using exposure, thermal, surface material, and shape coefficients. The document is aimed at engineers, code writers, and others who need a common basis for roof snow load design, including special roof forms and selected control measures.

What does ISO/FDIS 4355 specify?

ISO/FDIS 4355 specifies methods for calculating snow load on roofs and for building national rules around that calculation. It is written as a design document, not a measurement manual, and it supports national codes that express ground snow data through zone maps, tables, or formulae.

The document is organized into six clauses and seven informative annexes. Clauses 4 to 6 give the load model, the ground snow load basis, and the main coefficients used in design.

AnnexWhat it covers
Annex ABackground on selected snow parameters, including ground snow load data, snow density, rain on snow surcharge load, climate change, and statistical treatment
Annex BSnow load distribution on selected roof types, including pitched, flat, monopitched, multipitched, curved, multilevel, obstructed, and solar-panel roofs
Annex CDetermination of the exposure coefficient for small roofs
Annex DDetermination of the thermal coefficient
Annex ERoof snow retention devices
Annex FSnow loads on roofs with snow control
Annex GAlternative methods for roofs not covered by the document

ISO/FDIS 4355 also notes that unusual roofs or roofs not covered by the document may need special studies, and it does not deal with standard procedures or instrumentation for measurements.

What are the key requirements of ISO/FDIS 4355?

ISO/FDIS 4355 uses a semi-probabilistic approach. In practice, that means the designer starts from a regional ground snow load and then adjusts it for the roof, the site, the building geometry, and the thermal conditions.

  • Clause 4.1 defines roof snow load as a function of the characteristic ground snow load and several coefficients. The practical point is that roof load is not treated as a single fixed value - it depends on climate and roof-specific factors.

  • Clause 4.2 splits roof snow load into a basic load part, a drift load part, and a slide load part. This matters because many roofs do not carry snow uniformly, especially on leeward sides, lower roofs, or roofs where snow can move after accumulation.

  • Clause 4.3 requires consideration of partial loading caused by melting, sliding, snow redistribution, and snow removal. In practice, a roof may need to be checked for uneven or one-sided loading, not only for a uniform blanket of snow.

  • Clause 4.4 requires roofs to be designed against ponding instability. For flat or low-slope roofs, deflection under snow load must be checked because meltwater or rain-on-snow can create added water accumulation.

  • Clause 5 says the characteristic snow load on the ground, s0, is determined by statistical treatment of snow data. The document points to national snow-load maps and to Annex A for background, so the design basis comes from regional meteorological information rather than a single universal value.

  • Clause 6.1 introduces the exposure coefficient, Ce, which reflects how wind removes snow from a roof. For small roofs, Annex C gives Ce0, and for very large roofs the coefficient increases toward a higher limit. This matters because roof size and the surrounding terrain can change the snow retained on the roof.

  • Clause 6.2 introduces the thermal coefficient, Ct, to account for heat flow through the roof. Heated buildings, cold storage buildings, and glass-covered roofs can behave differently, so the same snow region can produce different roof loads depending on the building use.

  • Clause 6.3 and 6.4 use the surface material coefficient, Cm, and shape coefficients, including the basic load coefficient, μb, the drift load coefficient, μd, and the slide load coefficient, μs. These coefficients capture roof slope, roof surface, geometry, and wind effects, which is why Annex B gives different load distributions for different roof forms.

Annex B is especially important for practice because it gives different load patterns for pitched roofs, flat and monopitched roofs, multipitched roofs, curved roofs, lower roofs beside higher roofs, local obstructions, and roofs with solar panels. That helps a designer choose the correct load case for the actual roof shape instead of applying one generic pattern.

What terms does ISO/FDIS 4355 define?

  • Characteristic snow load on the ground [s0] - the ground snow load used as the regional starting point for roof snow load calculation, expressed in kN/m².

  • Shape coefficient [μ] - a coefficient that defines how snow is distributed across a roof section, mainly according to roof geometry.

  • Snow load on roof [s] - the roof snow load defined as a function of ground snow load and the relevant coefficients, with exposure and thermal effects included.

  • Drift load [s d] - extra snow load formed by wind-driven drifting, typically on leeward areas, lower roofs, or near obstructions.

  • Slide load [s s] - snow load that moves from an upper roof to a lower roof or lower roof part.

  • Exposure coefficient [Ce] - the ratio that expresses how much snow remains on a roof after wind erosion compared with a flat unheated roof under normal exposure.

  • Thermal coefficient [Ct] - the coefficient that adjusts snow load for heat flux through the roof, including melting and freezing effects in the snow layer.

  • Surface material coefficient [Cm] - the coefficient used for slippery, unobstructed roof surfaces where snow can slide more readily.

Who uses ISO/FDIS 4355?

ISO/FDIS 4355 is used by structural engineers, roof designers, and code writers who need snow loads for design and verification. It also matters to national standards bodies that prepare national snow-load provisions for their own climate.

It is used in practice by:

  • engineers designing roofs, frames, trusses, arches, domes, and multilevel roof systems
  • quality and compliance teams checking design assumptions for snow loading
  • authorities and standards committees writing national load codes
  • specialists working on snow-retention devices and snow-control systems
  • consultants using scale models, wind tunnels, water flumes, or computational methods for unusual roofs
  • designers of roofs with solar panels or obstructions where snow redistribution is important

What changed in ISO/FDIS 4355 from the previous edition?

ISO/FDIS 4355 is the fourth edition and cancels and replaces ISO 4355:2013. The foreword states that the document was technically revised.

The stated changes are:

  • updated guidance on basic meteorological data, including snow density, rain on snow surcharge load, and climate change
  • guidance added for snow load distribution on roofs with solar panels
  • improved guidance for determining the exposure coefficient for small roofs
  • improved guidance for determining the thermal coefficient
  • improved guidance for snow loads on roofs with snow load control
  • updated bibliography

Which standards are used with ISO/FDIS 4355?

ISO/FDIS 4355 names ISO 2394, General principles on reliability for structures. Annex F also refers to ISO 2394 when it requires a safety plan for malfunction of a snow control system, so the document uses that standard as its reliability and safety background.

What does the ISO/FDIS 4355 document contain?

ISO/FDIS 4355 contains the core load model, the coefficient-based calculation approach, and roof-type-specific guidance, supported by figures and formulas throughout the body. It includes a general functional expression for roof snow load, approximate load combinations, and guidance on partial loading and ponding instability.

Annex A gives statistical and meteorological background, including snow zones, snow density, rain on snow surcharge load, and climate change treatment. Annex B is the most detailed annex, with load distributions, case distinctions, and parameter definitions for selected roof geometries and special situations.

Annex C and Annex D provide methods and tables for exposure and thermal coefficients. Annex E covers snow retention devices, Annex F covers snow-control roofs, and Annex G describes alternative physical and computational methods for roofs not covered by the main document.

Relations

Effective Date
06-Jun-2022

Buy Documents

Draft

ISO/FDIS 4355 - Bases for design of structures — Determination of snow loads on roofs

Release Date:28-Oct-2026
English language (41 pages)
sale 15% off
sale 15% off
Draft

REDLINE ISO/FDIS 4355 - Bases for design of structures — Determination of snow loads on roofs

Release Date:28-Oct-2026
English language (41 pages)
sale 15% off
sale 15% off

Get Certified

Connect with accredited certification bodies for this standard

DIBt (Deutsches Institut für Bautechnik)

German Institute for Building Technology.

DAKKS Germany Verified

DIN CERTCO

DIN Group product certification.

DAKKS Germany Verified

Aboma Certification B.V.

Specialized in construction, metal, and transport sectors.

RVA Netherlands Verified

Sponsored listings

Frequently Asked Questions

ISO/FDIS 4355 is a draft published by the International Organization for Standardization (ISO). Its full title is "Bases for design of structures — Determination of snow loads on roofs". This standard covers: ISO 4355:2013 specifies methods for the determination of snow load on roofs. It can serve as a basis for the development of national codes for the determination of snow load on roofs. National codes should supply statistical data of the snow load on ground in the form of zone maps, tables, or formulae. The shape coefficients presented in ISO 4355:2013 are prepared for design application, and can thus be directly adopted for use in national codes, unless justification for other values is available. For determining the snow loads on roofs of unusual shapes or shapes not covered by ISO 4355:2013 or in national standards, it is advised that special studies be undertaken. These can include testing of scale models in a wind tunnel or water flume, especially equipped for reproducing accumulation phenomena, and should include methods of accounting for the local meteorological statistics. Examples of numerical methods, scale model studies, and accompanying statistical analysis methods are described in ISO 4355:2013 (Annex G). The annexes of ISO 4355:2013 describing methods for determining the characteristic snow load on the ground, exposure coefficient, thermal coefficient, and loads on snow fences are for information only as a consequence of the limited amount of documentation and available scientific results. In some regions, single winters with unusual weather conditions can cause severe load conditions not taken into account by ISO 4355:2013. Specification of standard procedures and instrumentation for measurements is not dealt with in ISo 4355:2013.

ISO 4355:2013 specifies methods for the determination of snow load on roofs. It can serve as a basis for the development of national codes for the determination of snow load on roofs. National codes should supply statistical data of the snow load on ground in the form of zone maps, tables, or formulae. The shape coefficients presented in ISO 4355:2013 are prepared for design application, and can thus be directly adopted for use in national codes, unless justification for other values is available. For determining the snow loads on roofs of unusual shapes or shapes not covered by ISO 4355:2013 or in national standards, it is advised that special studies be undertaken. These can include testing of scale models in a wind tunnel or water flume, especially equipped for reproducing accumulation phenomena, and should include methods of accounting for the local meteorological statistics. Examples of numerical methods, scale model studies, and accompanying statistical analysis methods are described in ISO 4355:2013 (Annex G). The annexes of ISO 4355:2013 describing methods for determining the characteristic snow load on the ground, exposure coefficient, thermal coefficient, and loads on snow fences are for information only as a consequence of the limited amount of documentation and available scientific results. In some regions, single winters with unusual weather conditions can cause severe load conditions not taken into account by ISO 4355:2013. Specification of standard procedures and instrumentation for measurements is not dealt with in ISo 4355:2013.

ISO/FDIS 4355 is classified under the following ICS (International Classification for Standards) categories: 91.080.01 - Structures of buildings in general. The ICS classification helps identify the subject area and facilitates finding related standards.

ISO/FDIS 4355 has the following relationships with other standards: It is inter standard links to ISO 4355:2013. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.

ISO/FDIS 4355 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.

Standards Content (Sample)

Contents

  • Introduction
  • 1 Scope
  • 2 Normative references
  • 3 Terms and definitions
  • 3.1 characteristic snow load on the ground
  • 3.2 shape coefficient
  • 3.3 snow load on roof
  • 3.4 drift load
  • 3.5 slide load
  • 3.6 basic load coefficient
  • 3.7 drift load coefficient
  • 3.8 slide load coefficient
  • 3.9 exposure coefficient
  • 3.10 exposure coefficient for small roofs
  • 3.11 effective roof length
  • 3.12 thermal coefficient
  • 3.13 surface material coefficient
  • 3.14 equivalent snow density
  • 3.15 snow density
  • 4 Snow loads on roofs
  • 4.1 General function describing intensity and distribution of the snow load on roofs
  • 4.2 Approximate formats for the determination of the snow load on roofs
  • 4.3 Partial loading due to melting, sliding, snow redistribution, and snow removal
  • 4.4 Ponding instability
  • 5 Characteristic snow load on the ground
  • 6 Snow load coefficients
  • 6.1 Exposure coefficient
  • 6.2 Thermal coefficient
  • 6.3 Surface material coefficient
  • 6.4 Shape coefficients
  • Annex A
  • Annex B
  • 0 C ≥1,0 µ (0)
  • Annex C
  • Annex D
  • Annex E
  • Annex F
  • Annex G
  • Bibliography

Introduction

The intensity and distribution of snow load on roofs can be described as functions of climate, topography, shape of building, roof surface material, heat flow through the roof, and time. Only limited and local data describing some of these functions are available. Consequently, for this document it was decided to treat the problem in a semi-probabilistic way.

The characteristic snow load on a roof area, or any other area above ground which is subject to snow accumulation, is defined in this document as a function of the characteristic snow load on the ground, s ,

specified for the region considered, and a shape coefficient which is defined as a product function, in which the various physical parameters are introduced as nominal coefficients. The shape coefficients will depend on climate, especially the duration of the snow season, wind, local topography, geometry of the building and surrounding buildings, roof surface material, building insulation, etc. The snow can be redistributed as a result of wind action; melted water can flow into local areas and refreeze; snow can slide or can be removed.

In order to apply this document, each country will have to establish maps and/or other information concerning the geographical distribution of snow load on ground in that country. Procedures for a statistical treatment of meteorological data are described in Annex A.

This document can serve as a basis for the development of national codes for the determination of snow load on roofs. National codes typically include statistical data of the snow load on ground in the form of zone maps, tables, or formulae.

The shape coefficients presented in this document are prepared for design application, and can thus be directly adopted for use in national codes, unless justification for other values is available. For determining the snow loads on roofs of unusual shapes or shapes not covered by this document or in national standards, special studies can be undertaken. These can include testing of scale models in a wind tunnel or water flume, especially equipped for reproducing accumulation phenomena, and can include methods of accounting for the local meteorological statistics. Examples of numerical methods, scale model studies, and accompanying statistical analysis methods are described in Annex G.

FINAL DRAFT International Standard ISO/FDIS 4355:2026(en) Bases for design of structures — Determination of snow loads on roofs

1 Scope

This document specifies methods for the determination of snow load on roofs. In some regions, single winters with unusual weather conditions can cause severe load conditions not taken into account by this document.

Specification of standard procedures and instrumentation for measurements is not dealt with in this document.

2 Normative references

There are no normative references in this document.

3 Terms and definitions

For the purposes of this document, the following terms and definitions apply. ISO and IEC maintain terminology databases for use in standardization at the following addresses:

  • ISO Online browsing platform: available at https:// www .iso .org/ obp
  • IEC Electropedia: available at https:// www .electropedia .org/

3.1 characteristic snow load on the ground

s

load with a specified annual exceedance probability

Note 1 to entry: It is expressed in kilonewton per square metre (kN/m ). Note 2 to entry: In meteorology, the term “weight of the ground snow cover” is also used.

3.2 shape coefficient

μ coefficient which defines the amount and distribution of the snow load on the roof (3.3) over a cross section of the building complex and primarily depends on the geometrical properties of the roof

3.3 snow load on roof

s function of the characteristic snow load on the ground (3.1), s , and appropriate shape coefficients (3.2)

Note 1 to entry: The value of s is also dependent on the exposure of the roof and the thermal conditions of the building. Note 2 to entry: It refers to a horizontal projection of the area of the roof.

Note 3 to entry: It is expressed in kilonewton per square metre (kN/m ).

ISO/FDIS 4355:2026(en)

3.4 drift load

s d additional load that can accumulate on a roof due to wind-driven drifting, typically on the leeward side on a pitched or curved roof, the lower roof of a multilevel roof or roofs with obstructions

3.5 slide load

s s load that can slide from an upper roof onto a lower roof, or a lower part of a roof

3.6 basic load coefficient

µ b coefficient defining the reduction of the snow load on the roof (3.3) due to a slope of the roof, β, and the surface material coefficient (3.13), C m

3.7 drift load coefficient

µ d coefficient which defines the amount and redistribution of additional load on a leeward side or part of a roof, depending on the exposure of the roof to wind, C , and the geometrical configurations of the roof e

3.8 slide load coefficient

µ s coefficient defining the amount and distribution of the slide load (3.5) on a lower part of a roof, or a lower level roof

3.9 exposure coefficient

C e coefficient defined as the ratio of the snow load remaining on the roof when some snow has been eroded by wind to the reference snow load on a flat unheated roof under normal exposure

3.10 exposure coefficient for small roofs

C e0 exposure coefficient (3.9) for roofs with effective roof length (3.11) shorter than 50 m

3.11 effective roof length

length of the roof influenced by exposure coefficient (3.9) given as a function of roof dimensions

3.12 thermal coefficient

C t coefficient defining the change in snow load on the roof (3.3) as a function of the heat flux through the roof Note 1 to entry: C , in some cases, can be greater than 1,0. Further guidance is given in 6.2 and Annex D. t

3.13 surface material coefficient

C m coefficient defining a reduction of the snow load on sloped roofs made of surface materials with low surface roughness

ISO/FDIS 4355:2026(en)

3.14 equivalent snow density

ρ e density for calculating the annual maximum snow load from annual maximum snow depth

3.15 snow density

ρ ratio between snow load and snow depth

4 Snow loads on roofs

4.1 General function describing intensity and distribution of the snow load on roofs

Formally, the snow load on roofs can be defined as a function, F, of several parameters, as in Formula (1):

(1) where the symbols are as defined in Clause 3.

While C , C , and C are assumed constant for a roof or a roof surface, µ , µ , and µ generally vary throughout e t m b d s the roof.

4.2 Approximate formats for the determination of the snow load on roofs

This document defines the snow load on the roof as a combination of a basic load part, s , a drift load part, s , b d and a slide load part, s . Thus, for the most unfavourable condition (lower roof on leeward side) Formula (2) s applies:

(2) where “+” implies “to be combined with”.

Effects of the various parameters are simplified by the introduction of product functions, defined in Formula (3), Formula (4) and Formula (5).

(3) (4) (5) [1][2] The basic roof snow load, s , is uniformly distributed in all cases , except for curved roofs, where the b distribution varies with the slope, β (see information in Clause B.4). The basic load defines the load on a horizontal roof, and the load on the windward side of a pitched roof. Since any direction can be the wind direction, the basic load is treated as a symmetrical load on a symmetrical roof, thus defining a major part of the total load on the leeward side as well. NOTE 1 For information on roof snow retention devices, see Annex E. NOTE 2 For information on snow loads on roof with snow control, see Annex F.

4.3 Partial loading due to melting, sliding, snow redistribution, and snow removal

A load corresponding to severe imbalances resulting from snow removal, redistribution, sliding, melting, etc. (e.g. zero snow load on specific parts of the roof) should always be considered.

ISO/FDIS 4355:2026(en) Such considerations are particularly important for structures which are sensitive to unbalanced loading (e.g. curved roofs, arches, domes, collar beam roofs, continuous beam systems, roof trusses spanning from side wall to side wall) which are addressed in other clauses of this document.

4.4 Ponding instability

Roofs shall be designed to preclude ponding instability. For flat roofs (or with a small slope), roof deflections caused by snow loads shall be investigated when determining the likelihood of ponding instability from rain-on-snow or from snow meltwater.

5 Characteristic snow load on the ground

The characteristic snow load on the ground, s , is determined by statistical treatment of snow data.

Snow load measurements on the ground should be taken in an undisturbed area not subject to localized drifting.

Information on methods for the determination of the characteristic snow load on the ground, s , is described

in Annex A.

6 Snow load coefficients

6.1 Exposure coefficient

The exposure coefficient, C , should be used for determining the snow load on the roof. The choice of C e e should consider the future development around the site. For regions where there are no sufficient winter climatological data available, it is recommended to set C = 1,0. e NOTE In the case of significant uncertainties about the future development of wind exposure conditions, a safesided choice of C can be appropriate. e For most cases, the exposure coefficient, C , is equal to the exposure coefficient for small roofs, C . However, e e0 for very large flat roofs, wind is less effective in removing snow from the whole roof. To compensate for this, the exposure coefficient for large roofs is higher than for smaller roofs as given in Formula (6). (6) where l is the effective roof length equal to in metres;

C is the exposure coefficient for small roofs.

e0 Information on methods for the determination of C are given in Annex C. e0 In the expression for l , W is the length of the shorter side of the roof and L is the length of the longer side.

For non-rectangular roofs, W and L can be taken as the shorter and longer side of the roof’s major dimensions along two orthogonal axes. For example, for an elliptical shape, W is measured along the short axis and L along the long axis.

An overview of the exposure coefficient is shown in Figure 1.

ISO/FDIS 4355:2026(en) Key C = 1,2 e0 C = 1,0 e0 C = 0,8 e0 Y C e X l [m]

Figure 1 — Exposure coefficient, C , as a function of effective roof length, l e c

6.2 Thermal coefficient

The thermal coefficient, C (see 3.12), is introduced to account for the effect of thermal transmittance of the t roof. C adjusts the snow load caused by melting and/or freezing of water in the snow layer. t The snow load is reduced on roofs with high thermal transmittance because of melting caused by heat loss through the roof. For such cases and for glass-covered roofs in particular, C can take values less than unity. t For buildings where the internal temperature is intentionally kept below 0 °C (e.g. freezer buildings, ice skating arenas), C can have values higher than unity. For all other cases, C = 1,0 applies. t t Bases for the determination of C are the thermal transmittance of the roof, U , and the lowest temperature, t roof θ , to be expected for the space under the roof, and the snow load on the ground, s . in 0 Information on methods for the determination of C for roofs with high thermal transmittance is described t in Annex D.

6.3 Surface material coefficient

The amount of snow which slides off the roof will, to some extent, depend on the surface material of the roofing; see 6.4.2.

ISO/FDIS 4355:2026(en) The surface material coefficient, C (see 3.13), is defined to vary between unity and 1,333, and takes the m following fixed values:

  • C = 1,333 for slippery, unobstructed surfaces for which the thermal coefficient C < 0,9 (e.g. glass roofs); m t
  • C = 1,2 for slippery, unobstructed surfaces for which the thermal coefficient C > 0,9 (e.g. glass roofs over m t partially climatic conditioned space, metal roofs,);
  • C = 1,0 for all other surfaces.

m NOTE C = 1,2 can also be applied for slippery unobstructed surfaces with C < 0,9 if this is assumed to be more m t reasonable.

6.4 Shape coefficients

6.4.1 General principles

The shape coefficients define distribution of the snow load over a cross section of the building complex and depend primarily on the geometrical properties of the roof.

For pitched roof buildings with rectangular plan form, the distribution of the snow load in the direction parallel to the eaves is assumed to be uniform, corresponding to an assumed wind direction normal to the eaves.

The shape coefficients presented for selected types of roof (see information in Annex B), are illustrated for one specific wind direction. Since prevailing wind directions can not correspond to the wind directions during heavy snow falls, the condition that the wind during snow fall can have any direction with reference to the roof location should be considered when designing roofs.

6.4.2 Basic load coefficient

When snow on sloped roofs can slide off unobstructed, snow load on the roof will be reduced. The reduction of the snow load on the roof due to the slope, β, of the roof and the surface material coefficient, C , is defined m by the basic load coefficient, μ (see 3.6), which is given by Formula (7):

b (7) An overview of the basic load coefficient is shown in Figure 2.

ISO/FDIS 4355:2026(en) Key C = 1,33 m C = 1,2 m C = 1,0 m β roof angle Y μ b X β [°] Figure 2 — Basic load coefficient, µ , as a function of the roof angle, β, and the surface material b coefficient, C m

6.4.3 Drift load coefficient

The drift load coefficient, µ (see 3.7), is dependent on the roof geometry and the exposure coefficient, C , d e see information in Annex B.

6.4.4 Slide load coefficient

Slide load from an upper part of a roof onto a lower part of a roof will depend on the amount of snow that can slide down, and on the geometrical configuration of the roof.

The distribution of the slide load and the spreading out of the load will, in addition to the geometrical shape of the roof, depend on the properties of the sliding snow and on the friction on the upper roof from which the snow is sliding.

The slide load magnitude and distribution is incorporated in the slide load coefficient, µ (see 3.8). s In the cases when slide load should be considered, the slide load coefficient for different roof types can be found using the guidance in Annex B.

NOTE It can be relevant to consider impact loading due to slide load in the design.

ISO/FDIS 4355:2026(en)

Annex A

(informative)

Background on the determination of selected snow parameters A.1 Snow zones and maps The characteristic snow load on the ground, s , with an annual exceedance probability of 0,02 or other

values taking into account the importance of the building and the limit state considered, should be available in national standards.

Investigations have shown that near the coasts, not only the altitude but also the distance from the coast can influence the snow load.

NOTE On the treatment of statistical values, see guidance in Clause A.3. A.2 Use of basic meteorological data A.2.1 General To determine snow load on the ground, s , a sequence of maximum yearly snow loads is used. This parameter

can be determined on the basis of recordings of water equivalents, snow depths, precipitation, etc. For areas where there is snow every year, a preferable minimum recording length is 20 years. Snow sampling equipment and the observation procedure should be in accordance with WMO [3] [4] [5] recommendations . Preferably, snow courses with records of water equivalents should be used , . However, if water equivalent data are scarce, available data on snow depth can be used. For regions with missing or scarce ground snow load measurements, validated models may be used to estimate snow loads on the ground based on common meteorological data; these may include for instance [4] [5] hydrological, snowmelt, or temperature-index models , . Relevant uncertainties should be considered, for example:

  • model uncertainties;
  • uncertainties in the basic variables including statistical uncertainty;
  • uncertainty in the climate change effect.

NOTE A period of winter season, rather than a calendar year, is more appropriate to specify a maximum snow load on the ground.

A.2.2 Density of snow The average density of snow layer is an important parameter for determining snow load, since the snow depth has more recordings than the water equivalent at many stations. When determining annual maximum snow load by means of snow depth and density, it should be considered that these two parameters usually have a significant positive correlation before the occurrence of a year’s snow depth maximum, and negative afterwards. In heavy snow regions, there is usually a time lag between the annual maximum snow depth and the annual maximum snow load. This difference is due to densification of snow layers. Therefore, an equivalent density of snow needs to be used for determining s when based on

[6] the annual maximum snow depth .

Many formulae have been proposed due to different climates in different countries.

ISO/FDIS 4355:2026(en) [6] A formula for equivalent snow density on the ground with a return period of 100 years used in Japan is Formula (A.1):

(A.1) where

ρ is the equivalent snow density (kg/m ); e d is the snow depth (m); d is the reference snow depth of 1 m.

ref Formula (A.2) is for snow density in the USA. It relates the snow density at one point in time to the snow load at the same point in time:

(A.2) where

ρ is the snow density (kg/m );

s is the snow load on the ground (kN/m ).

Formula (A.2), written in terms of snow depth, is shown in Formula (A.3):

(A.3) where

ρ is the snow density (kg/m ); d is the snow depth (m).

[7][8] Based on observations of the German Weather Service (Deutscher Wetterdienst DWD) the approach in Formula (A.4) has been developed:

(A.4) where d is the snow depth (m);

ρ is the density of snow at the surface (kg/m );

ρ is the upper limiting value of the snow density;

d is the reference snow depth of 1 m.

ref 3 3 For Germany, the snow density at the surface usually is in the range from 170 kg/m to 190 kg/m , and the 3 3 upper limiting value ranges from 400 kg/m to 600 kg/m . The latter value is valid for wet climates. In China, the relationship between snow depth and snow density with a return period of 50 years has been [9] established for Northeast China where heavy snowfalls are frequently encountered simplified as shown in Formula (A.5):

(A.5) where

ρ is the snow density (kg/m ); h is the snow depth on the ground (m) at characteristic snow load on the ground.

Figure A.1 shows a comparison of Formula (A.1), Formula (A.3), Formula (A.4) and Formula (A.5) for snow [10] density .

ISO/FDIS 4355:2026(en) Key Formula (A.1) Formula (A.4), a) Formula (A.5) Formula (A.3) Formula (A.4), b)

Y ρ (kN/m ) X d (m) 3 3 NOTE For Formula (A.4): a) dry climate with surface density 170 kg/m and upper limit density 400 kg/m , b) wet 3 3 climate with surface density 190 kg/m and upper limit density 600 kg/m . Figure A.1 — Snow density, ρ, as a function of snow depth, d, according to Formula (A.1), Formula (A.3), Formula (A.4) and Formula (A.5) A.2.3 Snow intensities for short periods of time For roofs with high values of heat loss, the snow fall intensity for short periods of time, 24 h or even shorter, can be of particular interest of design.

...

Contents

  • Introduction
  • 1 Scope
  • 2 Normative references
  • 3 Terms and definitions
  • 3.1 characteristic snow load on the ground
  • 3.2 shape coefficient
  • 3.3 snow load on roof
  • 3.4 drift load
  • 3.5 slide load
  • 3.6 basic load coefficient
  • 3.7 drift load coefficient
  • 3.8 slide load coefficient
  • 3.9 exposure coefficient
  • 3.10 exposure coefficient for small roofs
  • 3.11 effective roof length
  • 3.12 thermal coefficient
  • 3.13 surface material coefficient
  • 3.14 equivalent snow density
  • 3.15 snow density
  • 4 Snow loads on roofs
  • 4.1 General function describing intensity and distribution of the snow load on roofs
  • 4.2 Approximate formats for the determination of the snow load on roofs
  • 4.3 Partial loading due to melting, sliding, snow redistribution, and snow removal
  • 4.4 Ponding instability
  • 5 Characteristic snow load on the ground
  • 6 Snow load coefficients
  • 6.1 Exposure coefficient
  • 6.2 Thermal coefficient
  • 6.3 Surface material coefficient
  • 6.4 Shape coefficients
  • Annex A
  • Annex B
  • 0 C ≥1,0 µ (0)
  • Annex C
  • Annex D
  • Annex E
  • Annex F
  • Annex G
  • Bibliography

Introduction

The intensity and distribution of snow load on roofs can be described as functions of climate, topography, shape of building, roof surface material, heat flow through the roof, and time. Only limited and local data describing some of these functions are available. Consequently, for this document it was decided to treat the problem in a semi-probabilistic way.

The characteristic snow load on a roof area, or any other area above ground which is subject to snow accumulation, is defined in this document as a function of the characteristic snow load on the ground, s ,

specified for the region considered, and a shape coefficient which is defined as a product function, in which the various physical parameters are introduced as nominal coefficients. The shape coefficients will depend on climate, especially the duration of the snow season, wind, local topography, geometry of the building and surrounding buildings, roof surface material, building insulation, etc. The snow can be redistributed as a result of wind action; melted water can flow into local areas and refreeze; snow can slide or can be removed.

In order to apply this document, each country will have to establish maps and/or other information concerning the geographical distribution of snow load on ground in that country. Procedures for a statistical treatment of meteorological data are described in Annex A.

This document can serve as a basis for the development of national codes for the determination of snow load on roofs. National codes typically include statistical data of the snow load on ground in the form of zone maps, tables, or formulae.

The shape coefficients presented in this document are prepared for design application, and can thus be directly adopted for use in national codes, unless justification for other values is available. For determining the snow loads on roofs of unusual shapes or shapes not covered by this document or in national standards, special studies can be undertaken. These can include testing of scale models in a wind tunnel or water flume, especially equipped for reproducing accumulation phenomena, and can include methods of accounting for the local meteorological statistics. Examples of numerical methods, scale model studies, and accompanying statistical analysis methods are described in Annex G.

ISO/DISFDIS 4355:2026(en) Bases for design of structures — Determination of snow loads on roofs

1 Scope

This document specifies methods for the determination of snow load on roofs. In some regions, single winters with unusual weather conditions can cause severe load conditions not taken into account by this document.

Specification of standard procedures and instrumentation for measurements is not dealt with in this document.

2 Normative references

The following documents are referred to in the text in such a way that some or all of their content constitutes requirements of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. ISO 2394, General principles on reliability for structures There are no normative references in this document.

3 Terms and definitions

For the purposes of this document, the following terms and definitions apply. ISO and IEC maintain terminology databases for use in standardization at the following addresses:

  • ISO Online browsing platform: available at https://www.iso.org/obphttps://www.iso.org/obp
  • IEC Electropedia: available at https://www.electropedia.org/https://www.electropedia.org/

3.1 characteristic snow load on the ground

s0 load with a specified annual exceedance probability

Note 1 to entry: It is expressed in kilonewton per square metre (kN/m ). Note 2 to entry: In meteorology, the term “weight of the ground snow cover” is also used.

3.2 shape coefficient

μ coefficient which defines the amount and distribution of the snow load on the roof (3.3) over a cross section of the building complex and primarily depends on the geometrical properties of the roof

3.3 snow load on roof

s function of the characteristic snow load on the ground (3.1,), s , and appropriate shape coefficients (3.2)

Note 1 to entry: The value of s is also dependent on the exposure of the roof and the thermal conditions of the building. Note 2 to entry: It refers to a horizontal projection of the area of the roof.

ISO/DISFDIS 4355:2026(en)

Note 3 to entry: It is expressed in kilonewton per square metre (kN/m ).

3.4 drift load

s d additional load that can accumulate on a roof due to wind-driven drifting, typically on the leeward side on a pitched or curved roof, the lower roof of a multilevel roof or roofs with obstructions

3.5 slide load

s s load that can slide from an upper roof onto a lower roof, or a lower part of a roof

3.6 basic load coefficient

µb coefficient defining the reduction of the snow load on the roof (3.3) due to a slope of the roof, β, and the surface material coefficient (3.13,), C m

3.7 drift load coefficient

µd coefficient which defines the amount and redistribution of additional load on a leeward side or part of a roof, depending on the exposure of the roof to wind, C , and the geometrical configurations of the roof e

3.8 slide load coefficient

µs coefficient defining the amount and distribution of the slide load (3.5) on a lower part of a roof, or a lower level roof

3.9 exposure coefficient

Ce coefficient defined as the ratio of the snow load remaining on the roof when some snow has been eroded by wind to the reference snow load on a flat unheated roof under normal exposure

3.10 exposure coefficient for small roofs

Ce0 exposure coefficient (3.9) for small roofs with effective roof length (3.11) shorter than 50 m

3.11 effective roof length

length of the roof influenced by exposure coefficient (3.9) given as a function of roof dimensions

3.12 thermal coefficient

Ct coefficient defining the change in snow load on the roof (3.3) as a function of the heat flux through the roof Note 1 to entry: Ct, in some cases, can be greater than 1,0. Further guidance is given in 6.2 and Annex DAnnex D..

ISO/DISFDIS 4355:2026(en)

3.13 surface material coefficient

Cm coefficient defining a reduction of the snow load on sloped roofs made of surface materials with low surface roughness

3.14 equivalent snow density

ρe density for calculating the annual maximum snow load from annual maximum snow depth

3.15 snow density

ρ ratio between snow load and snow depth

4 Snow loads on roofs

4.1 General function describing intensity and distribution of the snow load on roofs

Formally, the snow load on roofs can be defined as a function, F, of several parameters, as in Formula (1) ::

𝑠𝑠 = F(𝑠𝑠 ,𝐶𝐶 ,𝐶𝐶 ,𝐶𝐶 ,𝜇𝜇 ,𝜇𝜇 ,𝜇𝜇 ) (1) 0 e t m b d s where the symbols are as defined in Clause 3.

While C , C , and C are assumed constant for a roof or a roof surface, µ , µ , and µ generally vary throughout e t m b d s the roof.

4.2 Approximate formats for the determination of the snow load on roofs

This document defines the snow load on the roof as a combination of a basic load part, s , a drift load part, s , b d and a slide load part, s . Thus, for the most unfavourable condition (lower roof on leeward side) Formula (2) s applies:

𝑠𝑠 =𝑠𝑠 " + "𝑠𝑠 " + "𝑠𝑠 (2) b d s where “+” implies “to be combined with”.

Effects of the various parameters are simplified by the introduction of product functions, defined in Formula (3), Formula (4) and Formula (5).

𝑠𝑠 = 0,8 𝑠𝑠𝐶𝐶𝐶𝐶 𝜇𝜇 (3) b 0 e t b 𝑠𝑠 =𝑠𝑠 𝜇𝜇 𝜇𝜇 (4) d 0 b d 𝑠𝑠 =𝑠𝑠 𝜇𝜇 (5) s 0 s [1] [2] The basic roof snow load, s , is uniformly distributed in all cases , except for curved roofs, where the b distribution varies with the slope, β (see information in Clause B.4). The basic load defines the load on a horizontal roof, and the load on the windward side of a pitched roof. Since any direction can be the wind direction, the basic load is treated as a symmetrical load on a symmetrical roof, thus defining a major part of the total load on the leeward side as well. NOTE 1 For information on roof snow retention devices, see Annex E.

ISO/DISFDIS 4355:2026(en) NOTE 2 For information on snow loads on roof with snow control, see Annex F.

4.3 Partial loading due to melting, sliding, snow redistribution, and snow removal

A load corresponding to severe imbalances resulting from snow removal, redistribution, sliding, melting, etc. (e.g. zero snow load on specific parts of the roof) should always be considered. Such considerations are particularly important for structures which are sensitive to unbalanced loading (e.g. curved roofs, arches, domes, collar beam roofs, continuous beam systems, roof trusses spanning from side wall to side wall) which are addressed in other clauses of this document.

4.4 Ponding instability

Roofs shall be designed to preclude ponding instability. For flat roofs (or with a small slope), roof deflections caused by snow loads shall be investigated when determining the likelihood of ponding instability from rainon-snow or from snow meltwater.

5 Characteristic snow load on the ground

The characteristic snow load on the ground, s , is determined by statistical treatment of snow data.

Snow load measurements on the ground should be taken in an undisturbed area not subject to localized drifting.

Information on methods for the determination of the characteristic snow load on the ground, s , is described

in Annex A.

6 Snow load coefficients

6.1 Exposure coefficient

The exposure coefficient, C , should be used for determining the snow load on the roof. The choice of C should e e consider the future development around the site. For regions where there are no sufficient winter climatological data available, it is recommended to set C = 1,0. e NOTE In the case of significant uncertainties about the future development of wind exposure conditions, a safe-sided choice of C can be appropriate.

e For most cases, the exposure coefficient, C , is equal to the exposure coefficient for small roofs, C . However, e e0 for very large flat roofs, wind is less effective in removing snow from the whole roof. To compensate for this, the exposure coefficient for large roofs is higher than for smaller roofs as given in Formula (6). 𝐶𝐶 𝑙𝑙 ≤ 50 m e0 c 𝐶𝐶 =� (6) e −(𝑙𝑙−50)/200 𝑐𝑐 1,25− (1,25−𝐶𝐶 )𝑒𝑒 𝑙𝑙 > 50 m e0 c where

𝑊𝑊 l is the effective roof length equal to 2𝑊𝑊− in metres;

𝐿𝐿 Ce0 is the exposure coefficient for small roofs.

Information on methods for the determination of C are given in Annex C. e0 In the expression for l , W is the length of the shorter side of the roof and L is the length of the longer side.

ISO/DISFDIS 4355:2026(en) For non-rectangular roofs, W and L can be taken as the shorter and longer side of the roof’s major dimensions along two orthogonal axes. For example, for an elliptical shape, W is measured along the short axis and L along the long axis.

An overview of the exposure coefficient is shown in Figure 1.

1,30 1,20 1,10 1,00 0,90 0,80 0,70 0 100 200 300 400 500

Key Ce0 = 1,2 Ce0 = 1,0 Ce0 = 0,8 Y Ce X lc [m]

C e

ISO/DISFDIS 4355:2026(en) Figure 1 — Exposure coefficient, C , as a function of effective roof length, l e c

6.2 Thermal coefficient

The thermal coefficient, C (see 3.12), is introduced to account for the effect of thermal transmittance of the t roof. C adjusts the snow load caused by melting and/or freezing of water in the snow layer. t The snow load is reduced on roofs with high thermal transmittance because of melting caused by heat loss through the roof. For such cases and for glass-covered roofs in particular, C , can take values less than unity. t For buildings where the internal temperature is intentionally kept below 0 °C (e.g. freezer buildings, ice skating arenas), C , can have values higher than unity. For all other cases, C = 1,0 applies. t t Bases for the determination of C are the thermal transmittance of the roof, U , and the lowest temperature, t roof θ , to be expected for the space under the roof, and the snow load on the ground, s . in 0 for roofs with high thermal transmittance is described in Information on methods for the determination of C t Annex D.

6.3 Surface material coefficient

The amount of snow which slides off the roof will, to some extent, depend on the surface material of the roofing; see 6.4.2.

The surface material coefficient, C (see 3.13), is defined to vary between unity and 1,333, and takes the m following fixed values:

  • C = 1,333 for slippery, unobstructed surfaces for which the thermal coefficient C < 0,9 (e.g. glass roofs); m t
  • C = 1,2 for slippery, unobstructed surfaces for which the thermal coefficient C > 0,9 (e.g. glass roofs over m t partially climatic conditioned space, metal roofs, etc.);,);
  • C = 1,0 corresponds tofor all other surfaces.

m NOTE Cm = 1,2 can also be applied for slippery unobstructed surfaces with Ct < 0,9 if this is assumed to be more reasonable.

6.4 Shape coefficients

6.4.1 General principles

The shape coefficients define distribution of the snow load over a cross section of the building complex and depend primarily on the geometrical properties of the roof.

For pitched roof buildings with rectangular plan form, the distribution of the snow load in the direction parallel to the eaves is assumed to be uniform, corresponding to an assumed wind direction normal to the eaves.

The shape coefficients presented for selected types of roof (see information in Annex B), are illustrated for one specific wind direction. Since prevailing wind directions can not correspond to the wind directions during heavy snow falls, the condition that the wind during snow fall can have any direction with reference to the roof location should be considered when designing roofs.

ISO/DISFDIS 4355:2026(en)

6.4.2 Basic load coefficient

When snow on sloped roofs can slide off unobstructed, snow load on the roof will be reduced. The reduction of the snow load on the roof due to the slope, β, of the roof and the surface material coefficient, C , is defined m by the shapebasic load coefficient, μ (see 3.6), which is given by Formula (7):

b 1 𝛽𝛽 < 30(1/𝐶𝐶 ) m (60−𝐶𝐶 𝛽𝛽)/30 30(1/𝐶𝐶 ) <𝛽𝛽 < 60(1/𝐶𝐶 ) 𝜇𝜇 =� (7) b m m m 0 𝛽𝛽 > 60(1/𝐶𝐶 ) m An overview of the basic load coefficient is shown in Figure 2. 1,2

0,8 0,6 0,4 0,2

0 10 20 30 40 50 60 β[°]

Key C = 1,33 m C = 1,2 m C = 1,0 m β roof angle Y μ b X β [°] Figure 2 — Basic load coefficient, µ , as a function of the roof angle, β, and the surface material b coefficient, C m

b

ISO/DISFDIS 4355:2026(en)

6.4.3 Drift load coefficient

The drift load coefficient, µ (see 3.7), is dependent on the roof geometry and the exposure coefficient, C , see d e information in Annex B.

6.4.4 Slide load coefficient

Slide load from an upper part of a roof onto a lower part of a roof will depend on the amount of snow that can slide down, and on the geometrical configuration of the roof.

The distribution of the slide load and the spreading out of the load will, in addition to the geometrical shape of the roof, depend on the properties of the sliding snow and on the friction on the upper roof from which the snow is sliding.

The slide load magnitude and distribution is incorporated in the slide load coefficient, µ (see 3.8). s In the cases when slide load should be considered, the slide load coefficient for different roof types can be found using the guidance in Annex B.

NOTE It can be relevant to consider impact loading due to slide load in the design.

ISO/DISFDIS 4355:2026(en)

Annex A

(informative)

Background on the determination of selected snow parameters A.1 Snow zones and maps The characteristic snow load on the ground, s , with an annual exceedance probability of 0,02 or other values

taking into account the importance of the building and the limit state considered, should be available in national standards.

Investigations have shown that near the coasts, not only the altitude but also the distance from the coast can influence the snow load.

NOTE On the treatment of statistical values, see guidance in Clause A.3. A.2 Use of basic meteorological data A.2.1 General To determine snow load on the ground, s , a sequence of maximum yearly snow loads is used. This parameter

can be determined on the basis of recordings of water equivalents, snow depths, precipitation, etc. For areas where there is snow every year, a preferable minimum recording length is 20 years. Snow sampling equipment and the observation procedure should be in accordance with WMO [3] [4] [5] recommendations . Preferably, snow courses with records of water equivalents should be used , . However, if water equivalent data are scarce, available data on snow depth can be used. For regions with missing or scarce ground snow load measurements, validated models may be used to estimate snow loads on the ground based on common meteorological data; these may include for instance [4] [5] hydrological, snowmelt, or temperature-index models , . Relevant uncertainties should be considered, e.g.:for example:

  • model uncertainties;
  • uncertainties in the basic variables including statistical uncertainty;
  • uncertainty in the climate change effect.

NOTE A period of winter season, rather than a calendar year, is more appropriate to specify a maximum snow load on the ground.

A.2.2 Density of snow The average density of snow layer is an important parameter for determining snow load, since the snow depth has more recordings than the water equivalent at many stations. When determining annual maximum snow load by means of snow depth and density, it should be considered that these two parameters usually have a significant positive correlation before the occurrence of a year’s snow depth maximum, and negative afterwards. In heavy snow regions, there is usually a time lag between the annual maximum snow depth and the annual maximum snow load. This difference is due to densification

ISO/DISFDIS 4355:2026(en) of snow layers. Therefore, an equivalent density of snow needs to be used for determining s when based on

[6] the annual maximum snow depth .

Many formulae have been proposed due to different climates in different countries. [6] A formula for equivalent snow density on the ground with a return period of 100 years used in Japan is Formula (A.1):

𝑑𝑑 𝜌𝜌 = 73 + 240 (A.1)

e 𝑑𝑑 ref where

ρe is the equivalent snow density (kg/m ); d is the snow depth (m); dref is the reference snow depth of 1 m.

Formula (A.2) is for snow density in the USA. It relates the snow density at one point in time to the snow load at the same point in time:

𝜌𝜌 = 43,5 𝑠𝑠 + 224≤ 480 (A.2)

where

ρ is the snow density (kg/m );

s is the snow load on the ground (kN/m ).

Formula (A.2), written in terms of snow depth, is shown in Formula (A.3):

270/(1,2− 0,51𝑑𝑑) 𝑑𝑑 < 1,25 m 𝜌𝜌 =� (A.3) 480 𝑑𝑑≥ 1,25 m where

ρ is the snow density (kg/m ); d is the snow depth (m).

[7] [8] Based on observations of the German Weather Service (Deutscher Wetterdienst DWD)) the approach in Formula (A.4) has been developed:

𝜌𝜌 𝑑𝑑 𝜌𝜌 𝑑𝑑 ∞ ref 0 𝜌𝜌 = ln �1 + (exp( )− 1)� (A.4) 𝑑𝑑 𝜌𝜌 𝑑𝑑 ∞ ref where d is the snow depth (m);

ρ is the density of snow at the surface (kg/m );

ρ is the upper limiting value of the snow density;

d is the reference snow depth of 1 m.

ref 3 3 For Germany, the snow density at the surface usually is in the range from 170 kg/m to 190 kg/m , and the 3 3 upper limiting value ranges from 400 kg/m to 600 kg/m . The latter value is valid for wet climates. In China, the relationship between snow depth and snow density with a return period of 50 years has been [9] established for Northeast China where heavy snowfalls are frequently encountered simplified as shown in Formula (A.5) ::

𝜌𝜌 = 86,5ℎ + 141 (A.5)

ISO/DISFDIS 4355:2026(en) where

...