ISO/FDIS 4354
(Main)Wind actions on structures
- Status
- Not Published
- Technical Committee
- ISO/TC 98/SC 3 - Loads, forces and other actions
- Drafting Committee
- ISO/TC 98/SC 3/WG 2 - Wind actions on structures
- Current Stage
- 5020 - Proof sent to secretariat or FDIS ballot initiated: 8 weeks - 50 Approval
- Start Date
- 06-Oct-2026
- Due Date
- 06-Oct-2026
- Completion Date
- 06-Oct-2026
Buy Documents
ISO/FDIS 4354 - Wind actions on structures
REDLINE ISO/FDIS 4354 - Wind actions on structures
ISO/FDIS 4354 is an International Standard published by ISO on wind actions on structures. It specifies analytical methods for calculating characteristic wind loads, pressures, forces, moments and wind directionality effects for buildings, towers, chimneys, bridges and other structures, including components and appendages. The document is written for design work where wind loading must be assessed consistently, especially when local or national wind rules need to be bridged.
What does ISO/FDIS 4354 specify?
ISO/FDIS 4354 specifies methods for determining wind actions on structures for design use. It covers simple shapes and surroundings through analytical methods, and it points users to wind tunnel tests, computation-based methods or other specialized studies for complex shapes, unusual dynamic behavior or strong aerodynamic sensitivity.
The document is organized into clauses on wind actions, wind pressure, wind force, site peak dynamic pressure, exposure factor, pressure and force coefficients, dynamic response factor, aeroelastic instability, and methods of determination of wind loads. The annexes provide supporting methods, coefficient data, dynamic-response guidance, testing principles and reliability considerations.
| Annex | What it covers |
|---|---|
| Annex A | Determination of reference wind speed |
| Annex B | Determination of exposure factors |
| Annex C | Aerodynamic pressure and force coefficients |
| Annex D | Dynamic response factors |
| Annex E | Structures subject to critical excitation vortex resonance and aeroelastic instability |
| Annex F | Wind load effect combinations |
| Annex G | Wind tunnel testing |
| Annex H | Computation-based methods |
| Annex I | Reliability considerations |
The scope includes buildings, towers, chimneys, bridges and their components and appendages. It also covers the three main storm types named in the document: synoptic winds, thunderstorms and tropical cyclones.
What are the key requirements of ISO/FDIS 4354?
ISO/FDIS 4354 turns wind actions into design values by combining a regional wind speed, exposure effects, aerodynamic coefficients and, where needed, dynamic response factors. In practice, the document tells the user what to calculate, what to look up, and when to move from simple static treatment to specialist dynamic assessment.
Wind actions to consider
Clause 4 requires designers to consider excessive forces, deflection, fatigue, aeroelastic instability and occupant discomfort. It also says interference from existing and future nearby buildings should be considered, because surrounding structures can change the wind effect on the project.
Wind pressure and wind force
Clause 5 states that wind pressure is obtained from site peak dynamic pressure, pressure coefficient and dynamic response factor. It is applied normal to the surface, and both internal and external pressures must be considered. Clause 6 gives the corresponding force method for local areas and for the whole structure, including along-wind, across-wind, torsional and overturning actions. It also points to Annex F for load combinations, which matters when several wind effects act together.
Site wind speed and exposure
Clause 7 derives site peak dynamic pressure from a regional reference wind speed and an exposure factor. Clause 8 says the exposure factor captures height, terrain roughness, changes in terrain roughness and topography, with direction-dependent values where needed. Annex A explains how reference wind speed is converted between averaging times and exposure conditions, and Annex B gives the exposure-factor methods for different storm types.
Coefficients, openings and local effects
Clause 9 states that pressure and force coefficients may come from Annex C, wind tunnel tests in Annex G, computation-based data in Annex H, or other standards if the averaging time and exposure assumptions are made consistent. It also requires internal pressure to be considered for enclosed structures, so envelope openings and permeability are part of the load model. Annex C also introduces factors for area load effects and local load effects, which matters because large surfaces and edge zones behave differently.
Dynamic response and instability
Clause 10 defines the dynamic response factor as the allowance for gusts, wake effects and motion-induced forces. Clause 11 requires aeroelastic stability to be demonstrated at wind speeds beyond the design peak wind speed, with a minimum check tied to the ultimate limit state wind speed values named in the document. Clause 12 states that the peak velocity pressure method is the main calculation route, that Cdyn may be taken as unity when dynamic effects are negligible, and that complex or wind-sensitive structures need specialist study. Annex D supports the dynamic calculations, and Annex E covers vortex resonance and aeroelastic instability.
What terms does ISO/FDIS 4354 define?
ISO/FDIS 4354 uses symbols in Clause 3.1 to identify the main wind-load quantities.
- Vref - The regional peak reference wind speed used as the starting point for design wind speed.
- Vsite - The peak wind speed at the site after exposure effects are applied.
- qsite - The site peak dynamic pressure used in the wind pressure and wind force equations.
- Cexp - The exposure factor that adjusts reference wind speed for terrain, height and topography.
- Cp - The pressure coefficient that expresses aerodynamic pressure relative to reference wind pressure.
- CF - The force coefficient that expresses aerodynamic force relative to reference pressure and area.
- Cdyn - The peak dynamic response factor that accounts for dynamic amplification.
- Aref - The reference area used for force calculations on the structure or its part.
These symbols matter because they are the quantities designers combine when moving from regional wind data to load effects on cladding, frames and whole structures.
Who uses ISO/FDIS 4354?
ISO/FDIS 4354 is used by structural engineers, wind engineers, bridge engineers, and designers of towers, chimneys, masts, roofs and other wind-sensitive structures. It is also relevant to architects, fabricators, checking authorities, and quality or project managers who need a common basis for wind-load assumptions.
Wind tunnel laboratories and teams using computational fluid dynamics (CFD) use the document when they need to align test or simulation data with design calculations. Buyers and owners use it indirectly when they need to compare design approaches for tall buildings, long-span roofs, bridges, offshore structures or moving structures.
What changed in ISO/FDIS 4354 from the previous edition?
ISO/FDIS 4354 is the third edition and it replaces ISO 4354:2009. The document states these main changes:
- flowcharts were added to clarify wind-action procedures for cladding, local areas and whole-structure checks;
- the text was refocused on the peak wind speed method;
- conversion between different averaging times was retained;
- the mean wind speed methodology was removed;
- Annexes A, B, C and D were substantially revised;
- Annex H was fully revised to reflect current wind engineering practice;
- editorial changes were made throughout for readability and consistency.
Which standards are used with ISO/FDIS 4354?
ISO/FDIS 4354 names ISO 2394, General principles on reliability for structures, and states that the document is compatible with ISO 2394. Annex I also says reliability assessment shall be carried out in accordance with ISO 2394, so it provides the reliability framework for choosing design actions and target reliability.
ISO 10137, Bases for design of structures - Serviceability of buildings and walkways against vibrations, is cited in Annex D for assessing habitability with respect to wind-induced vibrations. It contributes the serviceability check for peak accelerations.
What does the ISO/FDIS 4354 document contain?
ISO/FDIS 4354 contains the calculation framework for wind pressures, forces and moments, plus the supporting data and procedures needed to apply it. The annexes provide reference-wind conversion methods, exposure profiles for different storm types, aerodynamic coefficients, dynamic-response methods, load combinations and guidance for wind tunnel testing and CFD.
It also contains flowcharts for local and whole-structure wind actions, tables for coefficients and exposure factors, and formulas for along-wind, across-wind and torsional response. Annex E gives guidance for vortex resonance and aeroelastic instability, while Annex I shows how reliability considerations feed into wind-action design choices.
Relations
- Effective Date
- 12-Apr-2025
- Effective Date
- 06-Jun-2022
Buy Documents
ISO/FDIS 4354 - Wind actions on structures
REDLINE ISO/FDIS 4354 - Wind actions on structures
Get Certified
Connect with accredited certification bodies for this standard

DIBt (Deutsches Institut für Bautechnik)
German Institute for Building Technology.
DIN CERTCO
DIN Group product certification.

Aboma Certification B.V.
Specialized in construction, metal, and transport sectors.
Sponsored listings
Frequently Asked Questions
ISO/FDIS 4354 is a draft published by the International Organization for Standardization (ISO). Its full title is "Wind actions on structures". This standard covers: Wind actions on structures
Wind actions on structures
ISO/FDIS 4354 is classified under the following ICS (International Classification for Standards) categories: 91.080.01 - Structures of buildings in general. The ICS classification helps identify the subject area and facilitates finding related standards.
ISO/FDIS 4354 has the following relationships with other standards: It is inter standard links to ISO 14644-14:2026, ISO 4354:2009. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
ISO/FDIS 4354 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
Contents
- Introduction
- 1 Scope
- 2 Normative references
- 3 Terms, definitions and symbols
- 3.1 Symbols
- 4 Wind actions
- 5 Wind pressure
- 6 Wind force
- 7 Site peak dynamic pressure
- 8 Exposure factor
- 9 Pressure and force coefficients
- 10 Dynamic response factor
- 11 Criterion for aeroelastic instability
- 12 Methods of determination of wind loads
- Annex A
- Annex B
- 3. Suburban 3 0,84 —
- 4. Urban 3 0,59 —
- Annex C
- 15 All values −0,3 q
- 1. Windward wall permeable 0,6 q
- 1. Windward wall permeable −0,1, 0,2 q
- Annex D
- Annex E
- Annex F
- 1 W 0,4W 0,4W
- 2 W 04, W κ W
- 3 W 04, κ W W
- 1 L T
- 1 Vvh site
- Annex G
- Annex H
- Annex I
- Bibliography
Introduction
This document is intended for use by countries lacking an adequate wind loading standard and as a reference to bridge between existing International Standards related to wind actions on structures. This document is based primarily on the peak wind speed methodology using a 3-second gust wind speed measured at a height of 10 m over open country terrain. Procedures for conversion between different windspeed averaging times are also provided. The analytical procedures can be applied to other averaging times with appropriate adjustment of the relevant parameters, as described in Annex A. Parameters without a specified averaging time are considered to correspond to a peak value with T = 3 s. Analytical methods are provided for the determination of design wind pressures, forces and associated structural effects, including along-wind response, across-wind response and wind directionality effects. For structures with complex geometry, unusual size, significant dynamic sensitivity, or complex aerodynamic behaviour, specialized engineering assessment can be necessary. Such assessment can include wind tunnel testing or computational fluid dynamics.
The data provided in the annexes are formally informative and limited to the most common applications but are intended to be used within the definitions of this document. Additional data will be periodically provided in ISO Technical Reports for use on the same basis.
FINAL DRAFT International Standard ISO/FDIS 4354:2026(en) Wind actions on structures
1 Scope
This document describes the actions of wind on structures and specifies methods for calculating the characteristic values of wind loads for use in the design of buildings, towers, chimneys, bridges and other structures, as well as their components and appendages.
The provisions of this document are compatible with ISO 2394 and other International Standards related to wind loads.
The document provides analytical methods for determining wind loading, including the evaluation of design pressures, along-wind and across-wind forces, moments and wind directionality effects for structures of simple shapes and surroundings.
For structures with complex shapes, unusual dynamic behaviour, or significant aerodynamic sensitivity (e.g. tall buildings, long span bridges, large span roofs, guyed masts, offshore and moving structures), or complex wind directionality effects, wind tunnel tests, computation-based methods, or other specialized studies can be used.
This document covers the three main storm types: synoptic winds, thunderstorms and tropical cyclones (hurricanes and typhoons).
2 Normative references
There are no normative references in this document.
3 Terms, definitions and symbols
No terms and definitions are listed in this document.
ISO and IEC maintain terminology databases for use in standardization at the following addresses:
- ISO Online browsing platform: available at https:// www .iso .org/ obp
- IEC Electropedia: available at https:// www .electropedia .org/
3.1 Symbols
For the purposes of this document, the following symbols apply. Symbol Term Unit
A tributary or local area (area of application of pressure coefficient C ) m p
A reference area for force on overall structure or part of structure m ref C peak dynamic response factor 1 dyn C peak exposure factor 1 exp C force coefficient 1 F C pressure coefficient (time and spatially averaged) 1 p C standard deviation force coefficient 1 σF F peak force N F peak force on a tributary or local area N loc
ISO/FDIS 4354:2026(en) Symbol Term Unit g peak factor 1 g wind speed peak factor 1
h mean roof height m I wind speed turbulence intensity 1
−2 p pressure Nm −2 q site peak dynamic pressure Nm site −1 V peak wind speed ms −1 V critical wind speed at the top of the structure ms hcr −1 V mean wind speed ms m −1 V regional peak reference wind speed (with return period) ms ref −1 V site peak velocity ms site
ρ air density kgm σ standard deviation of force N F
4 Wind actions
Wind actions considered in the design of structures can produce the following effects:
a) excessive forces or instability in the structure or its structural members or elements; b) excessive deflection or distortion of the structure or its elements; c) repeated dynamic loading causing fatigue of structural elements; d) aeroelastic instability, where the motion of the structure in the wind produces aerodynamic forces that augment the motion; e) excessive dynamic movements causing concern or discomfort to occupants or onlookers; Additionally, interference effects from existing and potential future buildings shall be considered, as these can amplify the aforementioned impacts.
NOTE Wind pressures and forces provided in this document represent equivalent static wind loads, not pure external excitations. These equivalent static wind loads are based on the assumption of linear elastic structural behaviour and can require special consideration when applied to designs in the plastic region.
5 Wind pressure
For the actions referred to in Clause 4 a), b), c) and e), the effective wind pressure, p, shall be determined using a relationship that incorporates the site dynamic pressure, q , as defined in Clause 7 and Clause 8, a site pressure coefficient, C , and a dynamic response factor, C . This relationship is represented by Formula (1):
p dyn p = q × C × C (1) site p dyn The wind pressure is assumed to act statically in a direction normal to the surface of the structure or element, unless tangential frictional forces are specifically identified. Both internal and external pressures shall be considered. Integration of these pressures shall be undertaken to determine net forces or forces for defined tributary areas. Wind effects from all directions shall be considered.
6 Wind force
For some structures, it can be appropriate to represent the wind forces, F, by their resultants. These resultants shall include along-wind (drag), across-wind (lift), torsional and overturning actions. Different
ISO/FDIS 4354:2026(en) magnitudes and distributions of the wind force can be necessary to evaluate the actions described in Clause 4 a), b), c) and e).
The derivation of effective wind forces on an element, or resultant forces and moments, shall be determined using the peak reference dynamic pressure method. This method assumes that dynamic effects can be represented by a maximum or peak loading effect based on a peak reference pressure combined with a mean pressure coefficient (or mean pressure coefficient modified for local effects related to the area of application and statistical characteristics), and a peak dynamic response factor, C . The general relationships are dyn given in Formulae (2) and (3):
F = q × C × C × A (2) loc site p dyn F = q × C × C × A (3) site F dyn ref Formula (2) is used for the force on a tributary or local area, A. Formula (3) is used for the total force on the whole structure or part of the structure. A and A are the area of application and projected area normal to ref the wind direction of the building at height z above the ground, respectively. The value of C may be taken dyn as 1,0, except where the structure is dynamically wind-sensitive, as described in Annex D. In many cases, the total loads on the whole structure will be determined from loads on various components, or facades, or from along-wind and across-wind components. These forces contribute simultaneously but are not usually well correlated. Methods for determining load combinations are given in Annex F. When using the dynamic method, the distribution of equivalent static wind forces should include not only the mean and fluctuating (background) wind forces acting on the structure’s exterior but also the inertial forces due to motions of the structure’s mass.
Figures 1 and 2 illustrates the procedures for determining wind actions on local areas and the whole structure, as discussed in this clause.
ISO/FDIS 4354:2026(en) Figure 1 — Flow chart of wind actions on cladding or local areas throughout the structure
Wind Actions on Local Areas Throughout the Structure Rectangular shape NO No complicated topography or surroundings Design Site Peak Dynamic Wind Pressure Coeficient, C p
Pressure q =0.5×(V ×C ) site ref exp (Clause 9) (Clause 7 and Clause 8) Reference wind speed,V YES ref Cladding or Parts of Structures Dynamic Response Max 3 s wind speed at 10 m height Factor, C (Clause 9) C =[C -C ]×K a×K p p,e l p,i dyn over lat, open terrain (Annex A) (Annex C) Wind Tunnel Testing Effective Wind Pressure Exposure Factor,C exp (Annex G) p=q ×C ×C site p dyn C = k ×k ×k exp tr,z topog trchange Local or Tributary Effective Internal Pressure k : terrain roughness and height Computation-based External Pressure Coeficient, Area Load Effect Factor, K a Local Load Effect Factor, K tr,z l Wind Force F =q ×C ×C ×A Coeficient, C (Annex C: C.6) loc site p ( ) ( ) Methods dyn C p,e (Annex C: C.5 ) p,i Annex C: C.7 Annex C: C.8 factor (Annex B: B.1-B.3) (Clause 5 and 6) (Annex H) k : terrain roughness change trchange factor (Annex B: B.4) (Annex B) Other Codes or Standards Topographic Factor, K topog (Annex B: B.5) Design Wind Loads
ISO/FDIS 4354:2026(en) Figure 2 — Flow chart of wind actions on the whole structure
7 Site peak dynamic pressure
The site peak dynamic pressure, q , shall be determined from the regionally derived reference wind site speed, V , along with appropriate exposure factors, C , related to wind speed for the site, as defined by ref exp Formula (4):
q = 0,5 × ρ(V ) (4) site site where ρ is the air density.
The peak design wind speed at the site, V , adjusted for local exposure conditions, is given by Formula (5):
site V = V C (5) site ref exp where the exposure factor is determined as described in Clause 8. The reference wind speed, typically specified for large geographical areas, serves as a baseline for adjusting to local conditions at the site where the structure is located. It refers to a standard exposure (i.e. roughness, height and topography), averaging time and the probability of exceedance over one year (which can be approximated by an average return period for design application as required from serviceability to ultimate limit state determinations). In some situations, the reference wind speed can vary with direction. In the annexes of this document, the standard exposure is defined at 10 m height in open country terrain, with q being based on a maximum 3-second mean gust wind speed, V . Analysis procedures and values site ref are provided in Annex A and Annex B.
ISO/FDIS 4354:2026(en) In certain cases, critical loading can occur at wind speeds differing from, and potentially lower than, those specified above (e.g. due to vortex shedding). These critical wind speeds, denoted V (with reference to hcr height h) shall be substituted for V . These cases are discussed in Annex D. site
8 Exposure factor
The exposure factor, C , related to wind speed, accounts for the variability of the wind speed at the site of exp the structure for each storm type. It considers the following factors:
a) height above ground level; b) roughness of the terrain (including change of roughness); c) topography.
Values of the exposure factor are provided in Annex B and may vary with wind direction. Further guidance and requirements on the application of directional design wind speeds are also given in Annex B.
9 Pressure and force coefficients
A pressure coefficient, C , is an aerodynamic wind-induced pressure expressed as a fraction of the p reference wind pressure. A force coefficient, C , is an aerodynamic wind-induced force expressed as a ratio F of the aerodynamic force exerted on a structure or its parts to the reference wind pressure multiplied by a reference area.
Both pressure and force coefficients are influenced by the shape of the structure, exposure conditions, relative wind direction, Reynolds number and averaging time. Values for pressure and force coefficients are provided in Annex C. These values are presented in tables as non-simultaneous values for the design of cladding or parts of the structure, and in figures as simultaneous distributions for the design of the loadbearing structure. Enclosed structures are subjected to internal pressures, which depend on the size and distribution of the openings in the building envelope and any pressurization, whether mechanical or otherwise. These internal pressures shall be considered by combining pressure coefficients for the external pressures with those for the internal pressures.
Pressure and force coefficients can be determined from one of the following sources:
a) Annex C; b) appropriate wind tunnel tests, as described in Annex G; c) appropriate computationally based data, as described in Annex H; d) other codes or standards, provided that any discrepancies (e.g. in averaging time and exposure conditions) are properly adjusted and adequate provision is made for a dynamic response factor.
10 Dynamic response factor
The dynamic response factor, C , accounts for the following actions of the wind:
dyn a) fluctuating pressures due to random wind gusts acting over part or all of the surface area of the structure; b) fluctuating pressures in the wake of the structure (vortex shedding), which produce resultant forces acting across-wind, along-wind and torsionally; c) fluctuating pressures induced by the motion of the structure itself due to wind.
ISO/FDIS 4354:2026(en) Information on these effects and the appropriate values for the dynamic response factor can be found in Annex D.
11 Criterion for aeroelastic instability
For structures affected by the wind actions, as specified in Clause 4 d), which can cause aeroelastic instability, it shall be demonstrated that the performance of the structure, without the application of additional load factors, is acceptable up to a wind speed exceeding the design peak wind speed. Unless alternative rational procedures are available, this wind speed shall be at least the ultimate limit state site peak velocity, V , or 1,5 times the ultimate limit state 10-min mean design wind speed for the site site location and height of the structure.
12 Methods of determination of wind loads
This document provides the method for determining design wind loads based on the peak velocity pressure. This method is intended for detailed application where dynamic response effects are significant, utilizing an appropriate peak dynamic response factor, as outlined in Annex D. When dynamic response effects are negligible, such as in the design of cladding for most typical structures or the main structural systems of small-sized to medium-sized structures with low dynamic response, the peak velocity pressure method may be simplified by considering the peak dynamic response factor, C , to be unity. dyn For certain wind-sensitive structures, supplementary specialist studies are recommended. These include structures that are particularly flexible, slender, tall or lightweight, or located within complex surroundings. Unusual geometries can also result in unexpectedly large wind responses. In these cases, expert studies, typically including wind tunnel testing, are advised. These tests assist to establish the overall structural loads and distribution of external local pressures. Suitable testing procedures are described in Annex G. This method of analysis is intended for use with performance-based and limit state design methods, with requirements based on an appropriate probability of exceedance for the regional reference wind speed, as defined in Clause 7.
This document can be used to interpret between national and regional wind loading standards using the relationships provided in Annex A and Annex B. When interpreting between national standards or using this document, the most applicable storm type to both ultimate limit state and serviceability design should be considered.
Alternative methods of analysis to those recommended in this document may be permitted if the level of safety achieved is generally equivalent to that of this document. Guidance on the level of safety is provided in Annex I.
ISO/FDIS 4354:2026(en)
Annex A
(informative)
Determination of reference wind speed A.1 General Clause 7 defines site peak dynamic pressures in terms of reference wind speeds and exposure factors. The reference wind speeds for any probability of exceedance in one year (average return period) shall be determined from regionally derived reference wind speeds. For use in this document, the reference wind speed will be referenced to standard averaging time and exposure, defined as follows:
- V is the maximum wind speed averaged over 3 s, referenced to a height of 10 m over flat open country ref terrain.
Many national standards are based on annual extremes, which can be appropriate when a single storm type causes the extremes. However, in general, yearly extremes do not form an appropriate basis for the extreme value analysis of wind speeds. This is particularly true when the respective storm phenomenon tends to occur in families or clusters. In such cases, more than one event corresponding to the analysed storm type might occur in a given year, while in another year no event of the analysed storm type might occur. The ensemble of yearly extremes, therefore, can contain irrelevant data and neglects other relevant data. The ensemble shall consist of independent extremes above an appropriate threshold for each storm type. A.2 Analysis procedures The defined reference wind speeds shall be obtained from regional wind speeds. If these wind speeds are not already referenced as outlined in Clause A.1, they shall be converted using the following procedures:
a) Conversion for wind speeds referenced to different terrain roughness or height, V , should use the tr, z exposure factors, C , as given in Annex B for the appropriate storm type, as per Formula (A.1):
exp V tr,z V = (A.1) ref C exp b) Conversion to wind speeds, V , referenced for different averaging times, T, shall use an averaging time T factor, k , which is based on a peak factor, g , and the turbulence intensity, I , as per Formulae (A.2) T v v and (A.3):
Vk= V (A.2) TT T= 3 600 s k 1 gI (A.3) Tv v The factor k relates to the maximum wind speed averaged over a given period of time (T in seconds) within T the hourly mean wind speed for a given hour. The peak factor, g primarily depends on the time over which v, the maximum wind speed is averaged, T, and is weakly dependent on height. A full derivation methodology is provided in References [3], [4] and [5], with a summary available in Reference [6]. For this document, average values of g for heights between 3 m and 300 m are presented in Table A.1, along with an evaluation
of k for a range of values of T for specific reference conditions of z = 10 m and z = 0,03 m. T 0
ISO/FDIS 4354:2026(en) The turbulence intensity, I , is defined as the standard deviation of wind speed divided by the hourly mean
wind speed, using Formula (A.4):
I (A.4)
V m, T3 600 s Table A.1 — Averaging peak factors, g, and evaluation of reference averaging time factor, k v T Averaging time Average peak factor Reference averaging time factor T (s) g k v T 1 3,90 1,62 3 3,00 1,53 10 2,40 1,42 30 1,65 1,27 100 0,90 1,15 600 0,28 1,05 3 600 0 1,00 The most common conversions needed for reference conditions in relation to averaging time, T, are:
- V = 1,53 V ref ref,T = 3 600 s
- V = 1,46 V ref ref,T = 600 s Anemometer measurements might not have been made in the open country reference conditions of z = 0,03 m, and more detailed correction can be needed to obtain the appropriate peak factor as well as the
...
Contents
- Introduction
- 1 Scope
- 2 Normative references
- 3 Terms, definitions and symbols
- 3.1 Symbols
- 4 Wind actions
- 5 Wind pressure
- 6 Wind force
- 7 Site peak dynamic pressure
- 8 Exposure factor
- 9 Pressure and force coefficients
- 10 Dynamic response factor
- 11 Criterion for aeroelastic instability
- 12 Methods of determination of wind loads
- Annex A
- Annex B
- 3. Suburban 3 0,84 —
- 4. Urban 3 0,59 —
- Annex C
- 15 All values −0,3 qsite,h
- 1. Windward wall permeable 0,6 qsite,h
- 1. Windward wall permeable −0,1, 0,2 qsite,h
- Annex D
- 6 T *
- Annex E
- Annex F
- 1 WD 0,4WL 0,4WT
- 2 WL κ WT
- 1 V vh site
- Annex G
- Annex H
- Annex I
- Bibliography
Introduction
This document is intended for use by countries lacking an adequate wind loading standard and as a reference to bridge between existing International Standards related to wind actions on structures. This document is based primarily on the peak wind speed methodology using a 3-second gust wind speed measured at a height of 10 m over open country terrain. Procedures for conversion between different wind-speed averaging times are also provided. The analytical procedures can be applied to other averaging times with appropriate adjustment of the relevant parameters, as described in Annex A. Parameters without a specified averaging time are considered to correspond to a peak value with T = 3 s. Analytical methods are provided for the determination of design wind pressures, forces and associated structural effects, including along-wind response, across-wind response and wind directionality effects. For structures with complex geometry, unusual size, significant dynamic sensitivity, or complex aerodynamic behaviour, specialized engineering assessment can be necessary. Such assessment can include wind tunnel testing or computational fluid dynamics.
The data provided in the annexes are formally informative and limited to the most common applications but are intended to be used within the definitions of this document. Additional data will be periodically provided in ISO Technical Reports for use on the same basis.
FINAL DRAFT International Standard ISO/DISFDIS 4354:20252026(en)
Wind actions on structures
1 Scope
This document describes the actions of wind on structures and specifies methods for calculating the characteristic values of wind loads for use in the design of buildings, towers, chimneys, bridges and other structures, as well as their components and appendages.
The provisions of this document are compatible with ISO 2394 and other International Standards related to wind loads.
The document provides analytical methods for determining wind loading, including the evaluation of design pressures, along-wind and across-wind forces, moments and wind directionality effects for structures of simple shapes and surroundings.
For structures with complex shapes, unusual dynamic behaviour, or significant aerodynamic sensitivity (e.g. tall buildings, long span bridges, large span roofs, guyed masts, offshore and moving structures), or complex wind directionality effects, wind tunnel tests, computation-based methods, or other specialized studies can be used.
This document covers the three main storm types: synoptic winds, thunderstorms and tropical cyclones (hurricanes and typhoons).
2 Normative references
The following documents are referred to in the text in such a way that some or all of their content constitutes requirements of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. ISO 2394, General principles on reliability for structures There are no normative references in this document.
3 Terms, definitions and symbols
No terms and definitions are listed in this document.
ISO and IEC maintain terminology databases for use in standardization at the following addresses:
- ISO Online browsing platform: available at https://www.iso.org/obp
- IEC Electropedia: available at https://www.electropedia.org/
3.1 Symbols
For the purposes of this document, the following symbols apply. Symbol Term Unit
A tributary or local area (area of application of pressure coefficient Cp) m
Aref reference area for force on overall structure or part of structure m
ISO/DISFDIS 4354:20252026(en) Cdyn peak dynamic response factor 1 C peak exposure factor 1 exp C force coefficient 1 F Cp pressure coefficient (time and spatially averaged) 1 CσF standard deviation force coefficient 1 F peak force N F peak force on a tributary or local area N loc g peak factor 1 gv wind speed peak factor 1 h mean roof height m I wind speed turbulence intensity 1
−2 p pressure Nm −2 qsite site peak dynamic pressure Nm −1 V peak wind speed ms −1 V critical wind speed at the top of the structure ms hcr −1 V mean wind speed ms m −1 Vref regional peak reference wind speed (with return period) ms −1 Vsite site peak velocity ms
ρ air density kgm σ standard deviation of force N F
4 Wind actions
Wind actions considered in the design of structures can produce the following effects:
a) excessive forces or instability in the structure or its structural members or elements; b) excessive deflection or distortion of the structure or its elements; c) repeated dynamic loading causing fatigue of structural elements; d) aeroelastic instability, where the motion of the structure in the wind produces aerodynamic forces that augment the motion; e) excessive dynamic movements causing concern or discomfort to occupants or onlookers; Additionally, interference effects from existing and potential future buildings shall be considered, as these can amplify the aforementioned impacts.
NOTE Wind pressures and forces provided in this document represent equivalent static wind loads, not pure external excitations. These equivalent static wind loads are based on the assumption of linear elastic structural behaviour and can require special consideration when applied to designs in the plastic region.
ISO/DISFDIS 4354:20252026(en)
5 Wind pressure
For the actions referred to in Clause 4 a), b), c) and e), the effective wind pressure, p, shall be determined using a relationship that incorporates the site dynamic pressure, q , as defined in Clause 7 and Clause 8, site a pressure coefficient, C , and a dynamic response factor, C . This relationship is represented by p dyn Formula (1):
p = q × C × C (1) site p dyn The wind pressure is assumed to act statically in a direction normal to the surface of the structure or element, unless tangential frictional forces are specifically identified. Both internal and external pressures shall be considered. Integration of these pressures shall be undertaken to determine net forces or forces for defined tributary areas. Wind effects from all directions shall be considered.
6 Wind force
For some structures, it maycan be appropriate to represent the wind forces, F, by their resultants. These resultants shall include along-wind (drag), across-wind (lift), torsional and overturning actions. Different magnitudes and distributions of the wind force maycan be necessary to evaluate the actions described in Clause 4 a), b), c) and e).
The derivation of effective wind forces on an element, or resultant forces and moments, shall be determined using the peak reference dynamic pressure method. This method assumes that dynamic effects can be represented by a maximum or peak loading effect based on a peak reference pressure combined with a mean pressure coefficient (or mean pressure coefficient modified for local effects related to the area of application and statistical characteristics), and a peak dynamic response factor, C . dyn The general relationships are given in Formulae (2) and (3):
F = q × C × C × A (2) loc site p dyn F = q × C × C × A (3) site F dyn ref Formula (2) is used for the force on a tributary or local area, A. Formula (3) is used for the total force on the whole structure or part of the structure. A and A are the area of application and projected area ref normal to the wind direction of the building at height z above the ground, respectively. The value of C dyn may be taken as 1,0, except where the structure is dynamically wind-sensitive, as described in Annex D. In many cases, the total loads on the whole structure will be determined from loads on various components, or facades, or from along-wind and across-wind components. These forces contribute simultaneously but are not usually well correlated. Methods for determining load combinations are given in Annex F.
When using the dynamic method, the distribution of equivalent static wind forces should include not only the mean and fluctuating (background) wind forces acting on the structure’s exterior but also the inertial forces due to motions of the structure’s mass.
Figures 1 and 2 illustrates the procedures for determining wind actions on local areas and the whole structure, as discussed in this clause.
ISO/DISFDIS 4354:20252026(en)
ISO/DISFDIS 4354:20252026(en)
Figure 1 — Flow chart of wind actions on cladding or local areas throughout the structure
ISO/DISFDIS 4354:20252026(en)
ISO/DISFDIS 4354:20252026(en)
Figure 2 — Flow chart of wind actions on the whole structure
7 Site peak dynamic pressure
The site peak dynamic pressure, q , shall be determined from the regionally derived reference wind site speed, V , along with appropriate exposure factors, C , related to wind speed for the site, as defined by ref exp Formula (4):
q = 0,5 × (ρ(V ) (4) site site where ρ is the air density.
In Formula (4), theThe peak design wind speed at the site, V , adjusted for local exposure conditions, is site given by Formula (5):
V = V C (5) site ref exp where the exposure factor is determined as described in Clause 8. The reference wind speed, typically specified for large geographical areas, serves as a baseline for adjusting to local conditions at the site where the structure is located. It refers to a standard exposure (i.e. roughness, height and topography), averaging time and the probability of exceedance over one year (which can be approximated by an average return period for design application as required from serviceability to ultimate limit state determinations). In some situations, the reference wind speed can vary with direction.
ISO/DISFDIS 4354:20252026(en) In the annexes of this document, the standard exposure is defined at 10 m height in open country terrain, with q isbeing based on a maximum 3-second mean gust wind speed, V . Analysis procedures and site ref values are provided in Annex A and Annex B.
In certain cases, critical loading can occur at wind speeds differing from, and potentially lower than, those specified above (e.g. due to vortex shedding). These critical wind speeds, denoted V (with reference to hcr height h) shall be substituted for V . These cases are discussed in Annex D. site
8 Exposure factor
The exposure factor, C , related to wind speed, accounts for the variability of the wind speed at the site exp of the structure for each storm type. It considers the following factors:
a) height above ground level,; b) roughness of the terrain (including change of roughness), and); c) topography.
Values of the exposure factor are provided in Annex B and may vary with wind direction. Further guidance and requirements on the application of directional design wind speeds isare also given in Annex B.
9 Pressure and force coefficients
A pressure coefficient, C , is an aerodynamic wind-induced pressure expressed as a fraction of the p reference wind pressure. A force coefficient, C , is an aerodynamic wind-induced force expressed as a F ratio of the aerodynamic force exerted on a structure or its parts to the reference wind pressure multiplied by a reference area.
Both pressure and force coefficients are influenced by the shape of the structure, exposure conditions, relative wind direction, Reynolds number and averaging time. Values for pressure and force coefficients are provided in Annex C. These values are presented in tables as non-simultaneous values for the design of cladding or parts of the structure, and in figures as simultaneous distributions for the design of the load-bearing structure.
Enclosed structures are subjected to internal pressures, which depend on the size and distribution of the openings in the building envelope and any pressurization, whether mechanical or otherwise. These internal pressures shall be considered by combining pressure coefficients for the external pressures with those for the internal pressures.
Pressure and force coefficients can be determined from one of the following sources:
a) Annex C; b) appropriate wind tunnel tests, as described in Annex G; c) appropriate computationally based data, as described in Annex H; d) other codes or standards, provided that any discrepancies (e.g. in averaging time and exposure conditions) are properly adjusted and adequate provision is made for a dynamic response factor.
10 Dynamic response factor
The dynamic response factor, C , accounts for the following actions of the wind:
dyn
ISO/DISFDIS 4354:20252026(en) a) fluctuating pressures due to random wind gusts acting over part or all of the surface area of the structure; b) fluctuating pressures in the wake of the structure (vortex shedding), which produce resultant forces acting across-wind, along-wind and torsionally; c) fluctuating pressures induced by the motion of the structure itself due to wind. Information on these effects and the appropriate values for the dynamic response factor can be found in Annex D.
11 Criterion for aeroelastic instability
For structures affected by the wind actions, as specified in Clause 4 d), which can cause aeroelastic instability, it shall be demonstrated that the performance of the structure, without the application of additional load factors, is acceptable up to a wind speed exceeding the design peak wind speed. Unless alternative rational procedures are available, this wind speed shall be at least the ultimate limit state site peak velocity, V , or 1,5 times the ultimate limit state 10-min mean design wind speed for the site site location and height of the structure.
12 Methods of determination of wind loads
This document provides the method for determining design wind loads based on the peak velocity pressure. This method is intended for detailed application where dynamic response effects are significant, utilizing an appropriate peak dynamic response factor, as outlined in Annex D. When dynamic response effects are negligible, such as in the design of cladding for most typical structures or the main structural systems of small-sized to medium-sized structures with low dynamic response, the peak velocity pressure method may be simplified by considering the peak dynamic response factor, C , to be dyn unity.
For certain wind-sensitive structures, supplementary specialist studies are recommended. These include structures that are particularly flexible, slender, tall or lightweight, or located within complex surroundings. Unusual geometries can also result in unexpectedly large wind responses. In these cases, expert studies, typically including wind tunnel testing, are advised. These tests assist to establish the overall structural loads and distribution of external local pressures. Suitable testing procedures are described in Annex G.
This method of analysis is intended for use with performance-based and limit state design methods, with requirements based on an appropriate probability of exceedance for the regional reference wind speed, as defined in Clause 7.
This document can be used to interpret between national and regional wind loading standards using the relationships provided in Annex A and Annex B. When interpreting between national standards or using this document, the most applicable storm type to both ultimate limit state and serviceability design should be considered.
Alternative methods of analysis to those recommended in this document may be permitted if the level of safety achieved is generally equivalent to that of this document. Guidance on the level of safety is provided in Annex I.
ISO/DISFDIS 4354:20252026(en)
Annex A
(informative)
Determination of reference wind speed A.1 General Clause 7 defines site peak dynamic pressures in terms of reference wind speeds and exposure factors. The reference wind speeds for any probability of exceedance in one year (average return period) shall be determined from regionally derived reference wind speeds. For use in this document, the reference wind speed will be referenced to standard averaging time and exposure, defined as follows:
- V is the maximum wind speed averaged over 3 s, referenced to a height of 10 m over flat open ref country terrain.
Many national standards are based on annual extremes, which can be appropriate when a single storm type causes the extremes. However, in general, yearly extremes do not form an appropriate basis for the extreme value analysis of wind speeds. This is particularly true when the respective storm phenomenon tends to occur in families or clusters. In such cases, more than one event corresponding to the analysed storm type might occur in a given year, while in another year no event of the analysed storm type might occur. The ensemble of yearly extremes, therefore, can contain irrelevant data and neglects other relevant data. The ensemble shall consist of independent extremes above an appropriate threshold for each storm type.
A.2 Analysis procedures The defined reference wind speeds shall be obtained from regional wind speeds. If these wind speeds are not already referenced as outlined in Clause A.1, they shall be converted using the following procedures:
a) Conversion for wind speeds referenced to different terrain roughness or height, V , should use the tr, z exposure factors, C , as given in Annex B for the appropriate storm type, as per Formula (A.1):
exp V tr,z V = (A.1) ref C exp b) Conversion to wind speeds, V , referenced for different averaging times, T, shall use an averaging T time factor, k , which is based on a peak factor, g , and the turbulence intensity, I , as per T v v Formulae (A.2) and (A.3):
V = kV (A.2) T TT= 3 600 s k 1+ gI (A.3) T vv The factor k relates to the maximum wind speed averaged over a given period of time (T in seconds) T within the hourly mean wind speed for a given hour. The peak factor, g primarily depends on the time v, over which the maximum wind speed is averaged, T, and is weakly dependent on height. A full derivation methodology is provided in References [2], [3], [4] and [45], with a summary available in Reference [5 [6]. For this document, average values of g for heights between 3 m and 300 m are presented in
ISO/DISFDIS 4354:20252026(en) Table A.1, along with an evaluation of k for a range of values of T for specific reference conditions of T z = 10 m and z = 0,03 m.
The turbulence intensity, I , is defined as the standard deviation of wind speed divided by the hourly
mean wind speed, using Formula (A.4):
σ
I = (A.4)
V m, T=3 600 s Table A.1 — Averaging peak factors, g , and evaluation of reference averaging time factor, k v T Averaging time Average peak factor Reference averaging time factor T (s) g k v T 1 3,90 1,62 3 3,00 1,53 10 2,40 1,42 30 1,65 1,27 100 0,90 1,15 600 0,28 1,05 3 600 0 1,00 The most common conversions needed for reference conditions in relation to averaging time, T, are:
- V = 1,53 V ref ref, T = 3 600 s
- V = 1,46 V ref ref, T = 600 s Anemometer measurements might not have been made in the open country reference conditions of z = 0,03 m, and more detailed correction maycan be needed to obtain the appropriate peak factor as well
as the conversions provided by Formula (A.1), such as using Formula (B.2) with Figure B.1. The hourly mean wind speed is more relevant for synoptic storms. However, for tropical cyclone storms and thunderstorms there are no statistically stationary values of the hourly mean wind speed. In these cases, an equivalent 10-minute mean wind speed can be used in this document to facilitate the determination of the dynamic response, although the use of the 3-second wind speed is recommended in thunderstorm climates. Additionally, historical wind speed data in thunderstorm climates shall be referenced to averaging times of 3-second or less to determine relevant extreme value design wind speeds.
ISO/DISFDIS 4354:20252026(en)
Annex B
(informative)
...