Guide for performance characterization of dosimeters and dosimetry systems for use in radiation processing

ISO/ASTM 52701:2013 provides guidance on determining the performance characteristics of dosimeters and dosimetry systems used in radiation processing. ISO/ASTM 52701:2013 describes the influence quantities that might affect the performance of dosimeters and dosimetry systems and that should be considered during dosimeter/dosimetry system characterization. Users of ISO/ASTM 52701:2013 are directed to existing standards and literature for procedures to determine the effects from individual influence quantities and from combinations of more than one influence quantity. Guidance is provided regarding the roles of the manufacturers, suppliers, and users in the characterization of dosimeters and dosimetry systems.

Guide standard pour la caractérisation de la performance des dosimètres et des systèmes de dosimétrie pour utilization dans le traitement des radiations

General Information

Status
Published
Publication Date
08-Dec-2013
Current Stage
9020 - International Standard under periodical review
Start Date
15-Jan-2024
Completion Date
15-Jan-2024
Ref Project

Buy Standard

Standard
ISO/ASTM 52701:2013 - Guide for performance characterization of dosimeters and dosimetry systems for use in radiation processing
English language
10 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

INTERNATIONAL ISO/ASTM
STANDARD 52701
First edition
2013-11-15
Guide for performance characterization
of dosimeters and dosimetry systems for
use in radiation processing
Guide standard pour la caractérisation de la performance des
dosimètres et des systèmes de dosimétrie pour utilization dans
le traitement des radiations
Reference number
ISO/ASTM 52701:2013(E)
© ISO/ASTM International 2013

---------------------- Page: 1 ----------------------
ISO/ASTM 52701:2013(E)
PDF disclaimer
This PDF file may contain embedded typefaces. In accordance with Adobe’s licensing policy, this file may be printed or viewed but
shall not be edited unless the typefaces which are embedded are licensed to and installed on the computer performing the editing.
In downloading this file, parties accept therein the responsibility of not infringing Adobe’s licensing policy. Neither the ISO Central
Secretariat nor ASTM International accepts any liability in this area.
Adobe is a trademark of Adobe Systems Incorporated.
Details of the software products used to create this PDF file can be found in the General Info relative to the file; the PDF-creation
parameters were optimized for printing. Every care has been taken to ensure that the file is suitable for use by ISO member bodies
and ASTM members. In the unlikely event that a problem relating to it is found, please inform the ISO Central Secretariat or ASTM
International at the addresses given below.
© ISO/ASTM International 2013
All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form or by any means, electronic or
mechanical, including photocopying and microfilm, without permission in writing from either ISO at the address below or ISO’s member body in the
country of the requester. In the United States, such requests should be sent to ASTM International.
ISO copyright office ASTM International,100 Barr Harbor Drive, PO Box C700,
Case postale 56 • CH-1211 Geneva 20 West Conshohocken, PA 19428-2959, USA
Tel. +41 22 749 01 11 Tel. +610 832 9634
Fax +41 22 749 09 47 Fax +610 832 9635
E-mail copyright@iso.org E-mail khooper@astm.org
Web www.iso.org Web www.astm.org
Published in Switzerland
ii © ISO/ASTM International 2013 – All rights reserved

---------------------- Page: 2 ----------------------
ISO/ASTM 52701:2013(E)
Contents Page
1 Scope. 1
2 Referenced documents. 1
3 Terminology. 2
4 Significance and use. 2
5 Dosimeter/dosimetry system characterization. 3
6 Effect of influence quantities. 3
7 Documentation. 6
8 Repeat of performance characterization. 6
9 Measurement uncertainty. 7
10 Keywords. 7
Annexes. 7
Table 1 Examples of performance characteristics of dosimeters/dosimetry systems. 3
Table 2 Examples of influence quantities. 4
3
Table A1.1 Example of 2 factorial design. 7
Table A2.1 Influence quantities to be used in the irradiation experiments. 8
Table A2.2 Irradiations to 10 kGy. 9
Table A2.3 Irradiations to 45 kGy. 9
Table A2.4 ANOVA of experimental effects for 10 kGy. 9
Table A2.5 ANOVA of experimental effects for 45 kGy.
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.