ISO 16110-2:2010
(Main)Hydrogen generators using fuel processing technologies — Part 2: Test methods for performance
Hydrogen generators using fuel processing technologies — Part 2: Test methods for performance
ISO 16110-2:2010 provides test procedures for determining the performance of packaged, self-contained or factory matched hydrogen generation systems with a capacity less than 400 m3/h at 0 °C and 101,325 kPa, referred to as hydrogen generators, that convert a fuel to a hydrogen‑rich stream of composition and conditions suitable for the type of device using the hydrogen (e.g. a fuel cell power system, or a hydrogen compression, storage and delivery system).
Générateurs d'hydrogène faisant appel aux technologies du traitement du carburant — Partie 2: Méthodes d'essai de rendement
General Information
Standards Content (Sample)
INTERNATIONAL ISO
STANDARD 16110-2
First edition
2010-02-15
Hydrogen generators using fuel
processing technologies —
Part 2:
Test methods for performance
Générateurs d'hydrogène faisant appel aux technologies du traitement
du carburant —
Partie 2: Méthodes d'essai de rendement
Reference number
ISO 16110-2:2010(E)
©
ISO 2010
---------------------- Page: 1 ----------------------
ISO 16110-2:2010(E)
PDF disclaimer
This PDF file may contain embedded typefaces. In accordance with Adobe's licensing policy, this file may be printed or viewed but
shall not be edited unless the typefaces which are embedded are licensed to and installed on the computer performing the editing. In
downloading this file, parties accept therein the responsibility of not infringing Adobe's licensing policy. The ISO Central Secretariat
accepts no liability in this area.
Adobe is a trademark of Adobe Systems Incorporated.
Details of the software products used to create this PDF file can be found in the General Info relative to the file; the PDF-creation
parameters were optimized for printing. Every care has been taken to ensure that the file is suitable for use by ISO member bodies. In
the unlikely event that a problem relating to it is found, please inform the Central Secretariat at the address given below.
COPYRIGHT PROTECTED DOCUMENT
© ISO 2010
All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form or by any means,
electronic or mechanical, including photocopying and microfilm, without permission in writing from either ISO at the address below or
ISO's member body in the country of the requester.
ISO copyright office
Case postale 56 • CH-1211 Geneva 20
Tel. + 41 22 749 01 11
Fax + 41 22 749 09 47
E-mail copyright@iso.org
Web www.iso.org
Published in Switzerland
ii © ISO 2010 – All rights reserved
---------------------- Page: 2 ----------------------
ISO 16110-2:2010(E)
Contents Page
Foreword .iv
Introduction.v
1 Scope.1
2 Normative references.1
3 Terms, definitions and symbols .2
3.1 Terms and definitions .2
3.2 Symbols.3
4 Test conditions .3
4.1 Test boundary.3
5 Measurement technique .5
5.1 General .5
5.2 Operational parameters .5
5.3 Environmental aspects .6
5.4 Ambient conditions .8
6 Test plan.8
6.1 General .8
6.2 Test operating modes .8
6.3 Measurement, test frequency and duration.10
6.4 Uncertainty analysis.11
7 Test procedure.11
7.1 Safe operation of the hydrogen generator and test equipment .11
7.2 Execution of the test plan.11
8 Calculations .12
8.1 Electrical power input .12
8.2 Calculation of flow rates.13
8.3 Calculation of fuel, steam and hydrogen energy .15
8.4 Calculation of efficiency .20
9 Test reports.21
9.1 General .21
9.2 Summary report.21
9.3 Detailed report .22
9.4 Full report.22
Annex A (normative) Symbols and abbreviated terms .23
Annex B (informative) Guidance for uncertainty analysis.26
Annex C (normative) Calculation of fuel heating value .29
Annex D (informative) Definition of hydrogen generator efficiency.33
Annex E (informative) Reference gas .35
Bibliography.38
© ISO 2010 – All rights reserved iii
---------------------- Page: 3 ----------------------
ISO 16110-2:2010(E)
Foreword
ISO (the International Organization for Standardization) is a worldwide federation of national standards bodies
(ISO member bodies). The work of preparing International Standards is normally carried out through ISO
technical committees. Each member body interested in a subject for which a technical committee has been
established has the right to be represented on that committee. International organizations, governmental and
non-governmental, in liaison with ISO, also take part in the work. ISO collaborates closely with the
International Electrotechnical Commission (IEC) on all matters of electrotechnical standardization.
International Standards are drafted in accordance with the rules given in the ISO/IEC Directives, Part 2.
The main task of technical committees is to prepare International Standards. Draft International Standards
adopted by the technical committees are circulated to the member bodies for voting. Publication as an
International Standard requires approval by at least 75 % of the member bodies casting a vote.
Attention is drawn to the possibility that some of the elements of this document may be the subject of patent
rights. ISO shall not be held responsible for identifying any or all such patent rights.
ISO 16110-2 was prepared by Technical Committee ISO/TC 197, Hydrogen technologies.
ISO 16110 consists of the following parts, under the general title Hydrogen generators using fuel processing
technologies:
⎯ Part 1: Safety
⎯ Part 2: Test methods for performance
iv © ISO 2010 – All rights reserved
---------------------- Page: 4 ----------------------
ISO 16110-2:2010(E)
Introduction
This part of ISO 16110 describes how to measure and document the performance of stationary hydrogen
generators for residential, commercial and industrial applications.
The following hydrogen generation types have been considered:
⎯ hydrogen generators using fuel processing technologies.
© ISO 2010 – All rights reserved v
---------------------- Page: 5 ----------------------
INTERNATIONAL STANDARD ISO 16110-2:2010(E)
Hydrogen generators using fuel processing technologies —
Part 2:
Test methods for performance
1 Scope
This part of ISO 16110 provides test procedures for determining the performance of packaged, self-contained
3
or factory matched hydrogen generation systems with a capacity less than 400 m /h at 0 °C and 101,325 kPa,
herein referred to as hydrogen generators, that convert a fuel to a hydrogen-rich stream of composition and
conditions suitable for the type of device using the hydrogen (e.g. a fuel cell power system, or a hydrogen
compression, storage and delivery system).
2 Normative references
The following referenced documents are indispensable for the application of this document. For dated
references, only the edition cited applies. For undated references, the latest edition of the referenced
document (including any amendments) applies.
ISO 3744, Acoustics — Determination of sound power levels of noise sources using sound pressure —
Engineering method in an essentially free field over a reflecting plane
ISO 4677 (all parts), Atmospheres for conditioning and testing — Determination of relative humidity
ISO 5167 (all parts), Measurement of fluid flow by means of pressure differential devices inserted in circular
cross-section conduits running full
ISO 6060, Water quality — Determination of the chemical oxygen demand
ISO 6326 (all parts), Natural gas — Determination of sulfur compounds
ISO 6974 (all parts), Natural gas — Determination of composition with defined uncertainty by gas
chromatography
ISO 6975, Natural gas — Extended analysis — Gas-chromatographic method
ISO 7934, Stationary source emissions — Determination of the mass concentration of sulfur dioxide —
Hydrogen peroxide/barium perchlorate/Thorin method
ISO 9096, Stationary source emissions — Manual determination of mass concentration of particulate matter
ISO 10101 (all parts), Natural gas — Determination of water by the Karl Fischer method
ISO 10523, Water quality — Determination of pH
ISO 10707, Water quality — Evaluation in an aqueous medium of the “ultimate” aerobic biodegradability of
organic compounds — Method by analysis of biochemical oxygen demand (closed bottle test)
ISO 11042 (all parts), Gas turbines — Exhaust gas emission
© ISO 2010 – All rights reserved 1
---------------------- Page: 6 ----------------------
ISO 16110-2:2010(E)
ISO 11541, Natural gas — Determination of water content at high pressure
ISO 11564, Stationary source emissions — Determination of the mass concentration of nitrogen oxides —
Naphthylethylenediamine photometric method
ISO 14687-1, Hydrogen fuel — Product specification — Part 1: All applications except proton exchange
membrane (PEM) fuel cell for road vehicles
ISO 14687-2, Hydrogen fuel — Product specification — Part 2: Proton exchange membrane (PEM) fuel cell
applications for road vehicles
ISO 16622, Meteorology — Sonic anemometers/thermometers — Acceptance test methods for mean wind
measurements
IEC 61010-1, Safety requirements for electrical equipment for measurement, control, and laboratory use —
Part 1: General requirements
IEC 61672-1, Electroacoustics — Sound level meters — Part 1: Specifications
3 Terms, definitions and symbols
3.1 Terms and definitions
For the purposes of this document, the following terms and definitions apply.
3.1.1
audible noise level
sound pressure level produced by the hydrogen generator measured at a specified distance
NOTE Audible noise level is expressed as decibels (dBA) and measured as described in this part of ISO 16110.
3.1.2
background noise level
sound pressure level of ambient noise at the measurement point
3.1.3
cold state
condition of a hydrogen generator at ambient temperature with no substantial fuel or power input
3.1.4
discharge water
water that is released by the hydrogen generator
NOTE Discharge water does not constitute part of a thermal recovery system. It is comprised of the water treatment
waste and the process condensate shown in Figure 1.
3.1.5
hydrogen generator
system that converts a fuel to a hydrogen-rich stream
NOTE The hydrogen generator is composed of all or some of the following subsystems: a fuel processing system, a
fluid management system, a thermal management system, and other subsystems as described in more detail in
ISO 16110-1.
3.1.6
interface point
measurement point of a hydrogen generator at which material and/or energy either enters or leaves
2 © ISO 2010 – All rights reserved
---------------------- Page: 7 ----------------------
ISO 16110-2:2010(E)
3.1.7
return gas
tail gas
unused reformed hydrogen-rich gas, which returns to the hydrogen generator and is used as a fuel
NOTE Return gas generally includes hydrogen, carbon dioxide, water vapour and slipped hydrocarbon.
3.1.8
standby state
state in which the hydrogen generator is at operating temperature and is in an operational mode from which it
can be promptly switched to an operational mode with net hydrogen output
See Figure 2, item 2.
3.1.9
start-up time
time from cold start to supply of hydrogen gas at the rated hydrogen pressure
See Figure 2, item 1-3.
3.1.10
waste heat
thermal energy released and not recovered
3.2 Symbols
The symbols and their meanings are described in Annex A.
4 Test conditions/Test boundary
Hydrogen generators may have different subsystems depending on types of primary conversion processes
and applications, and they have different streams of material and energy in and out of them. However, a
common system diagram and boundary has been defined for evaluation of the hydrogen generator (see
Figure 1).
The following conditions shall be considered in order to determine the test boundary of the hydrogen
generator:
⎯ All energy recovery systems shall be included within the system boundary.
⎯ Calculation of the heating value of the input fuel (such as natural gas, propane gas, etc.) shall be based
on the conditions of the input fuel at the boundary of the hydrogen generator.
⎯ Calculation of the heating value of the output hydrogen containing gas stream shall be based on the
conditions of the gas stream at the boundary of the hydrogen generator.
⎯ Mechanical systems required for hydrogen generator operation (i.e. ventilation or micro-turbines,
expanders or compressors) shall be included inside the test boundary. The direct measurement of these
mechanical systems inside the test boundary is not required; however, their effects shall be included in
the hydrogen generator operation. If mechanical (shaft) power and energy cross the test boundary,
additional measurements and calculations may be necessary.
NOTE This part of ISO 16110 does not take into account mechanical (shaft) power or mechanical energy inputs or
outputs.
© ISO 2010 – All rights reserved 3
---------------------- Page: 8 ----------------------
ISO 16110-2:2010(E)
1 system boundary of the hydrogen generator including subsystems and the interface is defined as a conceptual
or functional one
2 inputs 3 outputs
2.1 steam (if imported) 3.1 water treatment waste
2.2 water 3.2 exhaust gas
2.3 treatment chemicals 3.3 process vents
2.4 air/oxidant 3.4 recovered heat
2.5 fuel 3.5 process condensate
2.6 purge gas 3.6 solid waste
2.7 cooling fluid 3.7 hydrogen
2.8 instrument gas 3.8 cooling fluid
2.9 electrical power input 3.9 ventilation exhaust
2.10 atmospheric air 3.10 noise
3.11 waste heat
4 subsystems (the configurations depend on the kind of fuel, type of fuel cell or system)
4.1 water treatment and steam generation
4.2 air/oxidant processing system
4.3 feedstock compression and processing
4.4 fuel processing system
4.5 hydrogen purification (optional)
4.6 hydrogen metering and analysis
4.7 process utilities (cooling fluid, purge gas, instrument gas, electrical, etc.)
4.8 ventilation system
:The interface points in the boundary to be measured for calculation data.
NOTE The fuel input can also consist of return gas.
Figure 1 — Typical hydrogen generator diagram
4 © ISO 2010 – All rights reserved
---------------------- Page: 9 ----------------------
ISO 16110-2:2010(E)
5 Measurement technique
5.1 General
The types of measuring instruments and measurement methods shall conform to the relevant International
Standards and shall be selected to meet the measurement uncertainty targets in line with the uncertainty
analysis of 6.4. If necessary, external equipment with required specification shall be added.
5.2 Operational parameters
5.2.1 Electrical power input
The electrical power input to the hydrogen generator, the voltage, the current and the power factor shall be
determined and measured in accordance with IEC 61010-1.
5.2.2 Input and output fluid characteristics
5.2.2.1 General
The composition, the heating value (only for fuels), the temperature, the pressure and the flow rate of the input
and output fluids shall be determined as per 5.2.2.2 to 5.2.2.6.
If there is fluctuation greater than ± 2 % in any measured value, the amplitude and the frequency of the
fluctuation shall be measured and reported as part of the test results.
5.2.2.2 Composition of fluids
The composition of each input and output fluid shall be measured. The measurement technique shall be
appropriate to the chemical composition of the fluid in question. If the fluid is not critical to operability or utility
consumption, direct measurement of the fluid composition shall not be required for conformance with this part
of ISO 16110.
If the only chemical oxidant employed is atmospheric air, only the moisture content shall be measured. The
moisture content value may be calculated from other direct measurements (e.g. wet bulb and dry bulb
temperatures) and reported as relative humidity.
The composition of natural gas shall be measured in accordance with methods detailed in ISO 6974 and
ISO 6975.
The sulfur compounds (including odorant) of natural gas shall be measured according to methods detailed in
ISO 6326.
The water vapour content of natural gas shall be measured according to methods detailed in ISO 10101 and
ISO 11541.
The hydrogen composition shall be determined using the test methods specified in ISO 14687-1 or
ISO 14687-2, as applicable.
The composition of other fluids shall be measured in accordance with the standard(s) appropriate to the fluids.
5.2.2.3 Heating value
The heating value of the input and output fluids shall only be measured for combustible fluids. The heating
value shall be determined through either calorimetric methods, or via calculation based on the fluid
composition as specified in Clause 8. The accuracy and detection limits of the composition measurement
technique shall be determined, and its effect on the uncertainty analysis of 6.4 shall be explicitly considered.
Pre-analysed bottled fuel gas may be substituted for gas sampling, provided that the uncertainty of the
analysed gas is consistent with the uncertainty required by the uncertainty analysis of 6.4.
© ISO 2010 – All rights reserved 5
---------------------- Page: 10 ----------------------
ISO 16110-2:2010(E)
In principle, the lower heating value (LHV) shall be used for all the calculations defined in this part of
ISO 16110. Should the higher heating value (HHV) be applied instead of LHV, the abbreviation “HHV” shall be
added to all the results that derive from the use of the HHV, such as the heating value of gaseous fuel
calculated as per Equation (15), the energy of gaseous fuel calculated as per Equation (16), the input energy
of gaseous fuel calculated as per Equation (15) and the efficiency calculated as per Annex D.
EXAMPLE If the value of efficiency is based on the HHV, it should be expressed as follows:
η = XX% (HHV)
h
NOTE In case of LHV, it is not necessary to add the abbreviation “LHV”.
5.2.2.4 Temperature
The temperature of each fluid shall be measured at the boundary of the hydrogen generator.
5.2.2.5 Pressure
The static pressure of each fluid shall be measured at the boundary of the hydrogen generator.
The height above grade shall be measured and recorded for input and output liquids.
The potential effects of condensable fractions shall be considered in the uncertainty analysis of 6.4 and in the
location of the pressure measurement means.
If the discharge of a particular fluid is to the atmosphere, its pressure need not be measured.
5.2.2.6 Flow rate
The flow rate of each fluid shall be measured at the boundary of the hydrogen generator.
Flow rates may be determined by means of a volumetric meter, mass flow meter or turbine type flow meter. If
such a method is not practicable, flow measurement by nozzles, orifices or venturi meters should be used and
they shall be applied in accordance with ISO 5167.
If a particular fluid is not chemically modified in the hydrogen generator, such as cooling fluid, instrument air or
purge gas, only the input or output flow rate shall be measured.
The effects of the flow measurement on the operability of the hydrogen generator shall be considered.
5.2.3 Solid output characteristics
Any solid outputs from the hydrogen generator, which is generated on a continuous basis, and which have to
be removed or disposed of continuously or in a repetitive batch operation, shall be characterized. The
following properties shall be measured:
a) composition;
b) mass generation rate;
c) frequency of removal, if a batch operation is necessary.
5.3 Environmental aspects
5.3.1 Particulate emission
Particulate emission in the exhaust gases shall be measured in accordance with ISO 9096.
6 © ISO 2010 – All rights reserved
---------------------- Page: 11 ----------------------
ISO 16110-2:2010(E)
5.3.2 SOx and NOx emission
5.3.2.1 SOx emission
SOx emission in the exhaust gases shall be measured in accordance with ISO 7934. Other methods suitable
for the service may be used providing they are consistent with the uncertainty analysis of 6.4.
5.3.2.2 NOx emission
NOx emission in the exhaust gases shall be measured in accordance with ISO 11564. Other methods suitable
for the service may be used providing they are consistent with the uncertainty analysis of 6.4.
5.3.3 CO and CO emission
2
CO emission in the exhaust gases shall be measured in accordance with ISO 11042-1 and ISO 11042-2.
2
CO may be calculated based on carbon content of the fuel.
2
CO emission in the exhaust gases shall be measured in accordance with ISO 11042-1 and ISO 11042-2.
5.3.4 Total hydrocarbon emission
Total hydrocarbon emission in the exhaust gases shall be measured in accordance with ISO 11042-1 and
ISO 11042-2.
5.3.5 Discharge water quality measurement
5.3.5.1 General
Quality measurements for water discharged from a hydrogen generator shall include the determination of:
a) volume of discharge water;
b) temperature of discharge water;
c) pH;
d) chemical oxygen demand (COD) or, if necessary, biochemical oxygen demand (BOD).
5.3.5.2 pH
The pH shall be measured in accordance with ISO 10523.
5.3.5.3 Chemical oxygen demand (COD)
The COD shall be measured in accordance with ISO 6060.
5.3.5.4 Biochemical oxygen demand (BOD)
When applicable, the BOD shall be measured in accordance with ISO 10707.
© ISO 2010 – All rights reserved 7
---------------------- Page: 12 ----------------------
ISO 16110-2:2010(E)
5.3.6 Audible noise level
The audible noise level produced by the hydrogen generator shall be measured using a sound level meter that
complies with IEC 61672-1. The test shall be conducted in accordance with ISO 3744 and shall record the
following parameters:
a) measuring surface (at distance from the body of hydrogen generator);
b) number of measuring points;
c) the background noise level, which shall be measured with the hydrogen generator in the cold state.
5.4 Ambient conditions
Ambient humidity, wind, pressure and temperature shall be measured.
Ambient humidity measurement shall be performed as per ISO 4677-1 and ISO 4677-2.
Ambient wind measurement shall be performed as per ISO 16622.
6 Test plan
6.1 General
A detailed test plan shall be prepared taking into consideration the following:
a) the test operating modes specified in 6.2;
b) the measurements, the test frequency and duration specified in 6.3;
c) the uncertainty analysis of 6.4.
6.2 Test operating modes
The hydrogen generator shall be tested in the operation modes listed below and shown in Figure 2:
a) start-up from cold state to the minimum hydrogen rated output;
b) steady-state operation at the minimum hydrogen rated output;
c) ramp-up from minimum hydrogen rated output to maximum hydrogen rated output;
d) steady-state operation at the maximum hydrogen rated output;
e) ramp-down from maximum hydrogen rated output to minimum hydrogen rated output;
f) shutdown to cold state;
g) standby state.
NOTE The hydrogen generator operating modes listed above do not prevent documentation of additional process
states in accordance with the methods of this part of ISO 16110, nor do they prevent inclusion of additional test data in the
data reports defined in this part of ISO 16110.
8 © ISO 2010 – All rights reserved
---------------------- Page: 13 ----------------------
ISO 16110-2:2010(E)
Key
X time
Y utility inputs
Z hydrogen product
Operating states
1 cold state
2 standby state (optional)
3 operational state (hydrogen product available)
4 maximum hydrogen rated output
Transitional states
1-3 cold state to operational state
2-3 standby state to operational state
3-4 ramp-up from minimum hydrogen rated output to maximum hydrogen rated output
4-3 ramp-down from maximum hydrogen rated output to minimum hydrogen rated output
Figure 2 — Hydrogen generator operating modes
For steady-state operational testing, the criteria in Table 1 shall be used to define the permissible deviations
allowed during testing for each parameter. For all transient testing, the parameters not directly affected by the
transient test shall be in accordance with Table 1.
© ISO 2010 – All rights reserved 9
---------------------- Page: 14 ----------------------
ISO 16110-2:2010(E)
Table 1 — Maximum permissible variations in test operating conditions
during a steady-state period
Average variation rate
Parameter
per hour
Power input, kW ± 2 %
Barometric pressure at site, kPa
± 0,5 %
Heating value, kJ/mol ± 2 %
Gaseous fuel pressure as delivered to system, kPa ± 1 %
Gaseous output hydrogen pressure, kPa ± 1 %
3
Fuel input and hydrogen output flow, m /s
± 2 %
During transients measured during ramp-up and ramp-down, impurity levels in the hydrogen product shall be
within the manufacturer's specifications.
6.3 Measurement, test frequency and duration
Measurements shall be taken during each phase of the test operating sequence as shown in Table 2.
NOTE For hydrogen generators not equipped with one or more of the operating modes, no measurements are
required and no results need to be included in the test report. If relevant, other steady-state outputs between minimum and
maximum hydrogen rated output may be selected.
Table 2 — Test item and system status
Steady-state conditions Ramp-up
and ramp-
Start-up
Maximum Minimum
down
Item Test Standby and
hydrogen hydrogen
shutdown
rated rated
output output
Operational aspects
1 Electrical power input as per 5.2.1 × × × ×
2 Input fluid characteristics as per 5.2.2 × × × × ×
3 Output fluid characteristics as per 5.2.2 × × × × ×
4 Solid output characteristics as per 5.2.3 × × × ×
Environmental aspects
1 Particulate emissions as per 5.3.1 × × ×
2 SOx and NOx emissions as per 5.3.2 × × ×
3 CO and CO emissions as per 5.3.3 × × ×
2
4 Total hydrocarbon emissions as per 5.3.4 × × ×
5 Discharge water quality as per 5.3.5 × × ×
6 Audible noise level as per 5.3.6 × × × × ×
The duration and frequency of measurements shall be determined according to the type of hydrogen
generator tested. A sufficient
...