Coke — Determination of moisture in the analysis sample

A known mass of the coke is heated in air at a temperature between 190 and 210 °C and maintained at this temperature until constant in mass. The percentage moisture content is calculated from the loss in mass of the coke.

Coke — Détermination de l'humidité de l'échantillon pour analyse

Koks - Določevanje vlage v analiziranem vzorcu

General Information

Status
Withdrawn
Publication Date
30-Sep-1974
Withdrawal Date
30-Sep-1974
Current Stage
9599 - Withdrawal of International Standard
Completion Date
03-Sep-2004

Relations

Buy Standard

Standard
ISO 687:1974 - Coke -- Determination of moisture in the analysis sample
English language
2 pages
sale 15% off
Preview
sale 15% off
Preview
Standard
ISO 687:1998
English language
2 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day
Standard
ISO 687:1974 - Coke -- Détermination de l'humidité de l'échantillon pour analyse
French language
2 pages
sale 15% off
Preview
sale 15% off
Preview
Standard
ISO 687:1974 - Coke -- Détermination de l'humidité de l'échantillon pour analyse
French language
2 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

INTERNATIONAL STANDARD
INTERNATIONAL ORGANIZATION FOR STANDARDIZATION 44EX~YHAPOAHMI OPTAHM3ALWI I-IO CTAH~APTtl3A~I4H.ORGANISATION INTERNATIONALE DE NORMALISATION
Coke - Determination of moisture in the analysis sample
Coke - De ’termina tion de l’humidite’ de l’bchan tillon pour analyse
First edition - 1974-10-01
UDC 662.749.2 : 543.812.2 Ref. No. IS0 687-1974 (E)
Descriptors : coke, chemical analysis, determination of content, moisture content, tests, physical tests, gravimetric analysis.
Price based on 2 pages

---------------------- Page: 1 ----------------------
FOREWORD
IS0 (the International Organization for Standardization) is a ’worldwide federation
of national standards institutes (IS0 Member Bodies). The work of developing
International Standards is carried out through IS0 Technical Committees. Every
Member Body interested in a subject for which a Technical Committee has been set
up has the right to be represented on that Committee. International organizations,
governmental and non-governmental, in liaison with ISO, also take part in the work.
Draft International Standards adopted by the Technical Committees are circulated
to the Member Bodies for approval before their acceptance as International
Standards by the IS0 Council.
Prior to 1972, the results of the work of the Technical Committees were published
as IS0 Recommendations; these documents are now in the process of being
transformed into International Standards. As part of this process, Technical
Committee ISO/TC 27 has reviewed IS0 Recommendation R 687 and found it
technically suitable for transformation. International Standard IS0 687 therefore
replaces IS0 Recommendation R 6874968 to which it is technically identical.
IS0 Recommendation R 687 was approved by the Member Bodies of the following
countries :
Australia
Egypt, Arab Rep. of Poland
Austria France Romania
Belgium Germany South Africa, Rep. of
Brazil India Switzerland
Turkey
Canada Italy
Chile Japan United Kingdom
Colombia Korea, Rep. of U.S.A.
Czechoslovakia Netherlands U.S.S.R.
Denmark New Zealand
No Member Body expressed disapproval of the Recommendation.
No Member Body disapproved the transformation of lSO/R 687 into an
International Standard.
0 International Organization for Standardization, 1974 l
Printed in Switzerland

---------------------- Page: 2 ----------------------
IS0 687-1974 (E)
INTERNATIONAL STANDARD
Coke - Determination of moisture in the analysis sample
0 INTRODUCTION
4.2 Air oven, capable of maintaining a temperature within
the range 190 to 210 “C (see 9.1) and in which the
Since coke is hygroscopic, its moisture will vary with
atmosphere changes from 3 to 8 times per hour.
change of humidity of the atmosphere. The moisture in the
analysis sample should, therefore, be determined whenever
portions are weighed out for other analytical
4.3 Weighing vessels, shallow, of glass with ground-on
determinations, for example, for volatile matter, for
covers or of noncorrodible metal with well-fitting covers,
calorific value or for carbon and hydrogen. If all the
of such a size that the concentration of the coke layer does
portions taken for analysis are weighed out on the same day
not exceed 0,15 g/cm2 (see 9.3). Silica or porcelain dishes,
and at about the same time, and if the analyses are
of the same size and 10 to 15 mm deep, having suitable
proceeded with without delay, one determination of
covers, may also be used if precautions are taken to avoid
moisture should suffice.
the effect of absorption of moisture by the dishes.
4.4 Desiccator, containing a metal plate, preferably of
aluminium, and a suitable desiccant (see clause 3).
1 SCOPE AND FIELD OF APPLICATION
This International Standard specifies a method of
determining the moisture content of the analysis sample of
coke.
5 PREPARATION OF SAMPLE
The coke used for the determination is the analysis sample
ground to pass a sieve of 0,2 mm aperture. If the sample of
2 PR
...

SLOVENSKI STANDARD
SIST ISO 687:1998
01-februar-1998
.RNV'RORþHYDQMHYODJHYDQDOL]LUDQHPY]RUFX
Coke -- Determination of moisture in the analysis sample
Coke -- Détermination de l'humidité de l'échantillon pour analyse
Ta slovenski standard je istoveten z: ISO 687:1974
ICS:
75.160.10 Trda goriva Solid fuels
SIST ISO 687:1998 en
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------

SIST ISO 687:1998

---------------------- Page: 2 ----------------------

SIST ISO 687:1998
INTERNATIONAL STANDARD
INTERNATIONAL ORGANIZATION FOR STANDARDIZATION 44EX~YHAPOAHMI OPTAHM3ALWI I-IO CTAH~APTtl3A~I4H.ORGANISATION INTERNATIONALE DE NORMALISATION
Coke - Determination of moisture in the analysis sample
Coke - De ’termina tion de l’humidite’ de l’bchan tillon pour analyse
First edition - 1974-10-01
UDC 662.749.2 : 543.812.2 Ref. No. IS0 687-1974 (E)
Descriptors : coke, chemical analysis, determination of content, moisture content, tests, physical tests, gravimetric analysis.
Price based on 2 pages

---------------------- Page: 3 ----------------------

SIST ISO 687:1998
FOREWORD
IS0 (the International Organization for Standardization) is a ’worldwide federation
of national standards institutes (IS0 Member Bodies). The work of developing
International Standards is carried out through IS0 Technical Committees. Every
Member Body interested in a subject for which a Technical Committee has been set
up has the right to be represented on that Committee. International organizations,
governmental and non-governmental, in liaison with ISO, also take part in the work.
Draft International Standards adopted by the Technical Committees are circulated
to the Member Bodies for approval before their acceptance as International
Standards by the IS0 Council.
Prior to 1972, the results of the work of the Technical Committees were published
as IS0 Recommendations; these documents are now in the process of being
transformed into International Standards. As part of this process, Technical
Committee ISO/TC 27 has reviewed IS0 Recommendation R 687 and found it
technically suitable for transformation. International Standard IS0 687 therefore
replaces IS0 Recommendation R 6874968 to which it is technically identical.
IS0 Recommendation R 687 was approved by the Member Bodies of the following
countries :
Australia
Egypt, Arab Rep. of Poland
Austria France Romania
Belgium Germany South Africa, Rep. of
Brazil India Switzerland
Turkey
Canada Italy
Chile Japan United Kingdom
Colombia Korea, Rep. of U.S.A.
Czechoslovakia Netherlands U.S.S.R.
Denmark New Zealand
No Member Body expressed disapproval of the Recommendation.
No Member Body disapproved the transformation of lSO/R 687 into an
International Standard.
0 International Organization for Standardization, 1974 l
Printed in Switzerland

---------------------- Page: 4 ----------------------

SIST ISO 687:1998
IS0 687-1974 (E)
INTERNATIONAL STANDARD
Coke - Determination of moisture in the analysis sample
0 INTRODUCTION
4.2 Air oven, capable of maintaining a temperature within
the range 190 to 210 “C (see 9.1) and in which the
Since coke is hygroscopic, its moisture will vary with
atmosphere changes from 3 to 8 times per hour.
change of humidity of the atmosphere. The moisture in the
analysis sample should, therefore, be determined whenever
portions are weighed out for other analytical
4.3 Weighing vessels, shallow, of glass with ground-on
determinations, for example, for volatile matter, for
covers or of noncorrodible metal with well-fitting covers,
calorific value or for carbon and hydrogen. If all the
of such a size that the concentration of the coke layer does
portions taken for analysis are weighed out on the same day
not exceed 0,15 g/cm2 (see 9.3). Silica or porcelain dishes,
and at about the same time, and if the analyses are
of the same size and 10 to 15 mm deep, having suitable
proceeded with without delay, one determination of
covers, may also be used if precautions are taken to avoid
moisture should suffice.
the effect of absorption of moisture by the dishes.
4.4 Desiccator, containing a metal plate, preferably of
aluminium, and a suitable desiccant (see clause
...

NORME INTERNATIONALE
INTERNATIONAL ORGANIZATION FOR STANDARDIZATION +lEXAYHAPOAHAR OPI-AHW3AWM II0 CTAHAAPTU3ALJWH~ORGANISATION INTERNATIONALE DE NORMALISATION
Coke - Détermination de l’humidité de l’échantillon pour
analyse
Coke - Determination of moisture in the analysis sample
Première édition - 1974-10-01
CDU 662.749.2 : 543.812.2 Réf. NO : ISO 687-1974 (F;
Descripteurs : coke, analyse chimique, dosage, teneur en eau, essai, essai physique, analyse gravimétrique.
Prix basé sur 2 pages

---------------------- Page: 1 ----------------------
AVANT-PROPOS
L’ISO (Organisation Internationale de Normalisation) est une fédération mondiale
d’organismes nationaux de normalisation (Comités Membres KO). L’élaboration de
Normes Internationales est confiée aux Comités Techniques ISO. Chaque Comité
Membre intéressé par une étude a le droit de faire partie du Comité Technique
correspondant. Les organisations internationales, gouvernementales et non
gouvernementales, en liaison avec I’ISO, participent également aux travaux.
Les Projets de Normes Internationales adoptés par les Comités Techniques sont
soumis aux Comités Membres pour approbation, avant leur acceptation comme
Normes Internationales par le Conseil de I’ISO.
Avant 1972, les résultats des travaux des Comités Techniques étaient publiés
comme Recommandations ISO; maintenant, ces documents sont en cours de
transformation en Normes Internationales. Compte tenu de cette procédure, le
Comité Technique ISO/TC 27 a examiné la Recommandation lSO/R 687 et est
d’avis qu’elle peut, du point de vue technique, être transformée en Norme
Internationale. Celle-ci remplace donc la Recommandation lSO/R 6874968 à
laquelle elle est techniquement identique.
La Recommandation lSO/R 687 avait été approuvée par les Comités Membres des
pays suivants :
Afrique du Sud, Rép. d’ Corée, Rép. de Pologne
Allemagne
Danemark Roumanie
Australie Egypte, Rép. arabe d’ Royaume-Uni
Autriche France Suisse
Belgique Inde Tchécoslovaquie
Brésil
Italie Turquie
Canada
Japon U.R.S.S.
Chili
Nouvelle-Zélande U.S.A.
Colombie
Pays-Bas
Aucun Comité Membre n’avait désapprouvé la Recommandation.
Aucun Comité Membre n’a désapprouvé la transformation de la Recommandation
lSO/R 687 en Norme Internationale.
0 Organisation Internationale de Normalisation, 1974 l
Imprimé en Suisse

---------------------- Page: 2 ----------------------
ISO 6874974 (F)
NORME INTERNATIONALE
Coke - Détermination de l’humidité de l’échantillon pour
analyse
4.3 Vases à peser, plats, à couvercle rodé, en verre ou en
0 INTRODUCTION
métal résistant à la corrosion, et de dimensions telles que la
Le coke étant hygroscopique, son humidité varie en
concentration de la couche de coke ne dépasse pas
fonction des modifications de l’état hygrométrique de
0,15 g/cm* (voir 9.3). Des vases plats en porcelaine ou en
l’atmosphère et, par conséquent, on doit déterminer
silice, de la même dimension et de 10 à 15 mm de
l’humidité de l’échantillon pour analyse chaque fois que
profondeur, ayant des couvercles appropriés, peuvent être
l’on pèse des prises d’essai destinées à d’autres
utilisés si des précautions sont prises pour éviter l’effet de
déterminations analytiques, telles que matières volatiles,
l’absorption de l’humidité par ces vases.
pouvoir calorifique, carbone et hydrogène. Si toutes ces
prises d’essai prélevées sont pesées le même jour et à peu
près au même moment, et si on procède sans délai aux 4.4 Dessiccateur, contenant une plaque métallique, de
analyses, une seule détermination d’humidité peut suffire.
préférence en aluminium, et un déshydratant convenable
(voir chapitre 3).
1 OBJET ET DOMAINE D’APPLICATION
La présente Norme Internationale spécifie une méthode de
5 PRÉPARATION DE L’ÉCHANTILLON
détermination de l’humidité de l’échantillon de coke pour
analy’se.
Le coke utilisé pour la détermination de l’humidité est
l’échantillon pour analyse, broyé pour passer au tamis de
0,2 mm d’ouverture de maille. Si l’échantillon de coke
séché lors de la détermination de l’humidité totale est utilisé
2 PRINCIPE à la préparation de l’échantillon pour analyse, il n’est pas
nécessaire de le sécher à l’air après l’avoir broyé. Lors de
Une masse connue de coke est chauffée dans l’air, à une
l’emploi d’un échantillon séparé pour analyse, il convient de
température de 190 à 210 “C (voir 9.1
...

NORME INTERNATIONALE
INTERNATIONAL ORGANIZATION FOR STANDARDIZATION +lEXAYHAPOAHAR OPI-AHW3AWM II0 CTAHAAPTU3ALJWH~ORGANISATION INTERNATIONALE DE NORMALISATION
Coke - Détermination de l’humidité de l’échantillon pour
analyse
Coke - Determination of moisture in the analysis sample
Première édition - 1974-10-01
CDU 662.749.2 : 543.812.2 Réf. NO : ISO 687-1974 (F;
Descripteurs : coke, analyse chimique, dosage, teneur en eau, essai, essai physique, analyse gravimétrique.
Prix basé sur 2 pages

---------------------- Page: 1 ----------------------
AVANT-PROPOS
L’ISO (Organisation Internationale de Normalisation) est une fédération mondiale
d’organismes nationaux de normalisation (Comités Membres KO). L’élaboration de
Normes Internationales est confiée aux Comités Techniques ISO. Chaque Comité
Membre intéressé par une étude a le droit de faire partie du Comité Technique
correspondant. Les organisations internationales, gouvernementales et non
gouvernementales, en liaison avec I’ISO, participent également aux travaux.
Les Projets de Normes Internationales adoptés par les Comités Techniques sont
soumis aux Comités Membres pour approbation, avant leur acceptation comme
Normes Internationales par le Conseil de I’ISO.
Avant 1972, les résultats des travaux des Comités Techniques étaient publiés
comme Recommandations ISO; maintenant, ces documents sont en cours de
transformation en Normes Internationales. Compte tenu de cette procédure, le
Comité Technique ISO/TC 27 a examiné la Recommandation lSO/R 687 et est
d’avis qu’elle peut, du point de vue technique, être transformée en Norme
Internationale. Celle-ci remplace donc la Recommandation lSO/R 6874968 à
laquelle elle est techniquement identique.
La Recommandation lSO/R 687 avait été approuvée par les Comités Membres des
pays suivants :
Afrique du Sud, Rép. d’ Corée, Rép. de Pologne
Allemagne
Danemark Roumanie
Australie Egypte, Rép. arabe d’ Royaume-Uni
Autriche France Suisse
Belgique Inde Tchécoslovaquie
Brésil
Italie Turquie
Canada
Japon U.R.S.S.
Chili
Nouvelle-Zélande U.S.A.
Colombie
Pays-Bas
Aucun Comité Membre n’avait désapprouvé la Recommandation.
Aucun Comité Membre n’a désapprouvé la transformation de la Recommandation
lSO/R 687 en Norme Internationale.
0 Organisation Internationale de Normalisation, 1974 l
Imprimé en Suisse

---------------------- Page: 2 ----------------------
ISO 6874974 (F)
NORME INTERNATIONALE
Coke - Détermination de l’humidité de l’échantillon pour
analyse
4.3 Vases à peser, plats, à couvercle rodé, en verre ou en
0 INTRODUCTION
métal résistant à la corrosion, et de dimensions telles que la
Le coke étant hygroscopique, son humidité varie en
concentration de la couche de coke ne dépasse pas
fonction des modifications de l’état hygrométrique de
0,15 g/cm* (voir 9.3). Des vases plats en porcelaine ou en
l’atmosphère et, par conséquent, on doit déterminer
silice, de la même dimension et de 10 à 15 mm de
l’humidité de l’échantillon pour analyse chaque fois que
profondeur, ayant des couvercles appropriés, peuvent être
l’on pèse des prises d’essai destinées à d’autres
utilisés si des précautions sont prises pour éviter l’effet de
déterminations analytiques, telles que matières volatiles,
l’absorption de l’humidité par ces vases.
pouvoir calorifique, carbone et hydrogène. Si toutes ces
prises d’essai prélevées sont pesées le même jour et à peu
près au même moment, et si on procède sans délai aux 4.4 Dessiccateur, contenant une plaque métallique, de
analyses, une seule détermination d’humidité peut suffire.
préférence en aluminium, et un déshydratant convenable
(voir chapitre 3).
1 OBJET ET DOMAINE D’APPLICATION
La présente Norme Internationale spécifie une méthode de
5 PRÉPARATION DE L’ÉCHANTILLON
détermination de l’humidité de l’échantillon de coke pour
analy’se.
Le coke utilisé pour la détermination de l’humidité est
l’échantillon pour analyse, broyé pour passer au tamis de
0,2 mm d’ouverture de maille. Si l’échantillon de coke
séché lors de la détermination de l’humidité totale est utilisé
2 PRINCIPE à la préparation de l’échantillon pour analyse, il n’est pas
nécessaire de le sécher à l’air après l’avoir broyé. Lors de
Une masse connue de coke est chauffée dans l’air, à une
l’emploi d’un échantillon séparé pour analyse, il convient de
température de 190 à 210 “C (voir 9.1
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.