kSIST FprEN IEC 60335-2-11:2026
(Main)Household and similar electrical appliances - Safety - Part 2-11: Particular requirements for tumble dryers
- Abstract
This European Standard deals with the safety of electric tumble dryers intended for household and similar purposes. The rated voltage being not more than 250 V for single-phase appliances and 480 V for other appliances.
- Status
- Not Published
- Public Enquiry End Date
- 30-Jan-2026
- Technical Committee
- VGA - Safety of household and similar electrical appliances
- Current Stage
- 5020 - Formal vote (FV) (Adopted Project)
- Start Date
- 26-Nov-2026
- Due Date
- 14-Jan-2027
- Completion Date
- 26-Nov-2026
kSIST FprEN IEC 60335-2-11:2026 is SIST’s publication of a draft European standard based on International Electrotechnical Commission (IEC) 60335-2-11:2024. It specifies safety requirements for electric tumble dryers intended for household and similar use, including the drying function of washing machines with a drying cycle, for manufacturers, test laboratories, and compliance teams.
What does kSIST FprEN IEC 60335-2-11:2026 specify?
kSIST FprEN IEC 60335-2-11:2026 covers the safety of electric tumble dryers with rated voltage not above 250 V for single-phase appliances and 480 V for other appliances, including direct current (DC) supplied appliances. It also covers heat pump type tumble dryers and communal-use machines such as those used in blocks of flats or launderettes.
The scope excludes appliances for industrial purposes, appliances used where special conditions prevail such as corrosive or explosive atmospheres, and appliances with steam generating devices above 50 kPa. The document is organized into Clauses 1 to 32, followed by normative Annex R, Annex AA and Annex BB.
| Annex | What it covers |
|---|---|
| Annex R | Software evaluation |
| Annex AA | Heat pump type tumble dryers |
| Annex BB | Non-sparking "n" electrical apparatus |
What are the key requirements of kSIST FprEN IEC 60335-2-11:2026?
The standard keeps the Part 1 safety framework and adds tumble-dryer-specific requirements. In practice, it tells manufacturers what to design, test, mark, and explain in the instructions so the appliance can be used safely in normal use and in foreseeable fault conditions.
Protection, marking, and instructions
Clause 6 requires at least IPX4, so the appliance must resist splashing water to a defined level. Clause 7 requires a visible instruction marking, clear off-position wording when letters are used, and detailed user instructions on load size, lint trap care, ventilation, unsafe cleaning residues, and warnings about stopping a cycle early. For some appliances, the instructions must also warn against external timers or repeated utility switching, which matters when the drying temperature is high.
Access, heating, and moisture
Clauses 8, 11, and 15 focus on touch safety and overheating. Additional test-probe access applies to parts near the floor, the temperature-rise limits are checked with the door closed, and lint traps are treated as part of the heating test. Moisture tests cover wet loads, blocked condensation outlets, overflow, and liquid spillage over controls. This means the appliance must remain safe if it gets wet during normal use, servicing, or a spill.
Abnormal operation and fire risk
Clause 19 requires testing with dry textile material, blocked air paths, disabled belt conditions, and other fault conditions that can lead to overheating or ignition. The textile load must not ignite, and lamp covers exposed to lint must also be tested for fire risk. Clause 30 adds a fire-spread test for non-metallic parts close to heating elements or exposed to falling lint. For a buyer or engineer, this is the part that addresses the most serious real-world hazard - fire.
Mechanical safety and construction
Clauses 20 and 22 deal with door safety, stability, interlocks, remote operation, cool down, steam generators, and stacking on washing machines. The door cannot open dangerously while the drum is running, inside opening force is limited for large doors, and open-door stability is checked with a load. Remote operation has extra controls for large-door appliances, and the cycle must end with a cool down period unless the drying temperature stays low enough. This reduces the risk of accidental access, tipping, and hot-load combustion.
Components, wiring, and insulation
Clauses 23, 24, and 29 cover internal wiring, component life, motor running capacitors, thermal cut-outs, and insulation requirements. The document also raises the tracking-resistance expectation for insulation exposed to condensation and includes a software evaluation path in Annex R for programmable electronic circuits. In practice, these clauses are aimed at durability and at preventing control faults from turning into unsafe operation.
What terms does kSIST FprEN IEC 60335-2-11:2026 define?
The standard defines the appliance types and a few test-related terms that control how compliance is checked.
- Tumble dryer - an appliance that dries textile material by tumbling it in a rotating drum while heated air is blown through it.
- Condensation-type tumble dryer - a tumble dryer that dehumidifies the drying air over an ambient heat exchanger and recirculates it in a closed loop.
- Heat pump type tumble dryer - a tumble dryer that uses a refrigerating system with sealed motor-compressors to perform the drying process.
- Steam generator - a device that produces steam at not more than 50 kPa and returns to atmospheric pressure when steam is not supplied.
- Cool down period - the final part of the cycle, with drum rotation and reduced heating, used to lower the risk of spontaneous combustion in the load.
- Flammable refrigerant - a refrigerant classified as A2L, A2, or A3 in ISO 817.
- Cheesecloth - a defined cotton cloth used in fire-related tests, especially around lamp covers.
Who uses kSIST FprEN IEC 60335-2-11:2026?
kSIST FprEN IEC 60335-2-11:2026 is used by tumble-dryer manufacturers, appliance designers, test laboratories, certification bodies, quality teams, and buyers who need to check safety claims or technical compliance. It is also relevant to makers of heat pump systems, motor-compressors, electronic controls, and stacked washer-dryer combinations.
What changed in kSIST FprEN IEC 60335-2-11:2026 from the previous edition?
This draft supersedes EN IEC 60335-2-11:2022 and its amendment and corrigendum set. The underlying IEC ninth edition states that it cancels and replaces the eighth edition published in 2019 and makes a technical revision.
The stated changes are:
- alignment with IEC 60335-1:2020
- conversion of some notes to normative text in Clause 1 and Annex AA
- new appliance-type definitions in 3.5.102 to 3.5.104
- new remote-operation requirements in 22.51
- new requirements for motor running capacitors in Clause 24
- modifications in Annex R
- updated requirements for flammable refrigerants in Clause 21 and Annex AA
- new requirements for non-sparking "n" electrical apparatus in Annex BB
Which standards are used with kSIST FprEN IEC 60335-2-11:2026?
The standard is used with IEC 60335-1, which supplies the general safety requirements that this Part 2 supplements and modifies. IEC 60335-2-34 contributes requirements for motor-compressors, especially for heat pump type tumble dryers.
The normative references also add the test and marking standards the document relies on:
- IEC 60068-2-6 for vibration testing
- IEC 60079 series, IEC 60079-7, and IEC 60079-15 for explosive atmospheres and non-sparking protection
- IEC 60584-1 for thermocouple specifications used in temperature measurement
- ISO 817 for refrigerant designation and safety classification
- ISO 7010:2019 for safety signs and warning symbols
What does the kSIST FprEN IEC 60335-2-11:2026 document contain?
The document contains the usual IEC 60335 clause structure plus an annex system for special cases. It includes a dedicated surface-temperature probe in Figure 101, a temperature-rise table for accessible surfaces in Table 101, and a motor-compressor temperature table in Annex AA.
It also contains detailed test methods for heating, moisture, abnormal operation, door-interlock behavior, stacking stability, remote operation, and fire spread near heating elements. Annex AA adds refrigerant-circuit, leak, vibration, and ignition-related checks for heat pump type tumble dryers, while Annex BB adapts non-sparking apparatus requirements for use with flammable refrigerants.
Relations
- Effective Date
- 10-Feb-2026
- Effective Date
- 03-Feb-2026
- Refers
SIST EN 60079-6:2007 - Explosive atmospheres -- Part 6: Equipment protection by oil immersion o - Effective Date
- 03-Feb-2026
- Effective Date
- 03-Feb-2026
- Refers
SIST EN 60079-11:2007 - Explosive atmospheres -- Part 11: Equipment protection by intrinsic safety i - Effective Date
- 03-Feb-2026
- Effective Date
- 03-Feb-2026
- Effective Date
- 03-Feb-2026
- Effective Date
- 03-Feb-2026
- Effective Date
- 03-Feb-2026
- Effective Date
- 03-Feb-2026
- Refers
SIST EN 60079-18:2010 - Explosive atmospheres -- Part 18: Equipment protection by encapsulation m - Effective Date
- 03-Feb-2026
- Refers
SIST EN 60079-5:2008 - Explosive atmospheres -- Part 5: Equipment protection by powder filling q - Effective Date
- 03-Feb-2026
- Effective Date
- 03-Feb-2026
- Effective Date
- 03-Feb-2026
- Effective Date
- 03-Feb-2026
Get Certified
Connect with accredited certification bodies for this standard
CIS Institut d.o.o.
Personal Protective Equipment (PPE) certification body. Notified Body NB-2890 for EU Regulation 2016/425 PPE.

Kiwa BDA Testing
Building and construction product certification.
Kmetijski inštitut Slovenije
Agricultural Institute of Slovenia. Soil testing, plant health, agricultural product analysis.
Sponsored listings
Frequently Asked Questions
kSIST FprEN IEC 60335-2-11:2026 is a draft published by the Slovenian Institute for Standardization (SIST). Its full title is "Household and similar electrical appliances - Safety - Part 2-11: Particular requirements for tumble dryers". This standard covers: This European Standard deals with the safety of electric tumble dryers intended for household and similar purposes. The rated voltage being not more than 250 V for single-phase appliances and 480 V for other appliances.
This European Standard deals with the safety of electric tumble dryers intended for household and similar purposes. The rated voltage being not more than 250 V for single-phase appliances and 480 V for other appliances.
kSIST FprEN IEC 60335-2-11:2026 is classified under the following ICS (International Classification for Standards) categories: 13.120 - Domestic safety; 97.060 - Laundry appliances. The ICS classification helps identify the subject area and facilitates finding related standards.
kSIST FprEN IEC 60335-2-11:2026 has the following relationships with other standards: It is inter standard links to oSIST prEN IEC 80000-17:2026, SIST EN 60079-6:2016, SIST EN 60079-6:2007, SIST EN 60079-25:2004, SIST EN 60079-11:2007, SIST EN 60079-26:2015, SIST EN 60079-31:2014, SIST EN 60079-17:2014, SIST EN 60079-5:2015/A1:2025, SIST EN 60079-0:2004, SIST EN 60079-18:2010, SIST EN 60079-5:2008, SIST EN 60079-14:2003, SIST EN 60079-14:1998, SIST EN 60079-17:1998. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
kSIST FprEN IEC 60335-2-11:2026 is associated with the following European legislation: EU Directives/Regulations: 2014/35/EU, 2014/53/EU; Standardization Mandates: M/511, M/536. When a standard is cited in the Official Journal of the European Union, products manufactured in conformity with it benefit from a presumption of conformity with the essential requirements of the corresponding EU directive or regulation.
kSIST FprEN IEC 60335-2-11:2026 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
Contents
- 1 Scope
- 2 Normative references
- 3 Terms and definitions
- 3.1 Definitions relating to physical characteristics
- 3.5 Definitions relating to types of appliances
- 3.6 Definitions relating to parts of an appliance
- 3.8 Definitions relating to miscellaneous matters
- 4 General requirement
- 5 General conditions for the tests
- 6 Classification
- 7 Marking and instructions
- 8 Protection against access to live parts
- 9 Starting of motor-operated appliances
- 10 Power input and current
- 11 Heating
- 12 Charging of metal-ion batteries
- 13 Leakage current and electric strength at operating temperature
- 14 Transient overvoltages
- 15 Moisture resistance
- 16 Leakage current and electric strength
- 17 Overload protection of transformers and associated circuits
- 18 Endurance
- 19 Abnormal operation
- 19.2 Not applicable
- 19.3 Not applicable
- 20 Stability and mechanical hazards
- 21 Mechanical strength
- 22 Construction
- 23 Internal wiring
- 24 Components
- 25 Supply connection and external flexible cords
- 26 Terminals for external conductors
- 27 Provision for earthing
- 28 Screws and connections
- 29 Clearances, creepage distances and solid insulation
- 30 Resistance to heat and fire
- 31 Resistance to rusting
- 32 Radiation, toxicity and similar hazards
- Annex R
- Annex AA
- 4 General requirement
- 5 General conditions for the tests
- 6 Classification
- 7 Marking and instructions
- 11 Heating
- 19 Abnormal operation
- 21 Mechanical strength
- 22 Construction
- Annex BB is not applicable provided that they can be used with group IIA gases or the
- 24 Components
- Annex BB
- 7 Requirements for non-incendive components
- 8 Requirements for hermetically sealed devices
- 9 Requirements for sealed devices
- 9.1 Non-metallic materials
- 9.6 Type tests
- 10 Requirements for restricted-breathing enclosures
- Bibliography
INTRODUCTION It has been assumed in the drafting of this International Standard that the execution of its provisions is entrusted to appropriately qualified and experienced persons. Guidance documents concerning the application of the safety requirements for appliances can be accessed via TC 61 supporting documents on the IEC website https://www.iec.ch/tc61/supportingdocuments This information is given for the convenience of users of this International Standard and does not constitute a replacement for the normative text in this standard. This standard recognizes the internationally accepted level of protection against hazards such as electrical, mechanical, thermal, fire and radiation of appliances when operated as in normal use taking into account the manufacturer's instructions. It also covers abnormal situations that can be expected in practice and takes into account the way in which electromagnetic phenomena can affect the safe operation of appliances.
This standard takes into account the requirements of IEC 60364 as far as possible so that there is compatibility with the wiring rules when the appliance is connected to the supply mains. However, national wiring rules can differ.
If an appliance within the scope of this standard also incorporates functions that are covered by another part 2 of IEC 60335, the relevant part 2 is applied to each function separately, as far as is reasonable. If applicable, the influence of one function on the other is taken into account.
When a part 2 standard does not include additional requirements to cover hazards dealt with in Part 1, Part 1 applies.
NOTE 1 This means that the technical committees responsible for the part 2 standards have determined that it is not necessary to specify particular requirements for the appliance in question over and above the general requirements.
This standard is a product family standard dealing with the safety of appliances and takes precedence over horizontal and generic standards covering the same subject. NOTE 2 Horizontal publications, basic safety publications and group safety publications covering a hazard are not applicable since they have been taken into consideration when developing the general and particular requirements for the IEC 60335 series of standards.
An appliance that complies with the text of this standard will not necessarily be considered to comply with the safety principles of the standard if, when examined and tested, it is found to have other features which impair the level of safety covered by these requirements. An appliance employing materials or having forms of construction differing from those detailed in the requirements of this standard may be examined and tested according to the intent of the requirements and, if found to be substantially equivalent, may be considered to comply with the standard.
NOTE 3 Standards dealing with non-safety aspects of household appliances are:
- IEC standards published by TC 59 concerning methods of measuring performance;
- CISPR 11, CISPR 14-1 and relevant IEC 61000-3 series standards concerning electromagnetic emissions;
- CISPR 14-2 concerning electromagnetic immunity;
- IEC standards published by TC 111 concerning environmental matters.
oSIST prEN IEC 60335-2-11:2026
HOUSEHOLD AND SIMILAR ELECTRICAL APPLIANCES – SAFETY –
Part 2-11: Particular requirements for tumble dryers
1 Scope
This clause of Part 1 is replaced by the following.
This part of IEC 60335 deals with the safety of electric tumble dryers intended for household and similar purposes, their rated voltage being not more than 250 V for single-phase appliances and 480 V for other appliances including direct current (DC) supplied appliances. This standard applies to the drying function of washing machines having a drying cycle. This standard also deals with the safety of heat pump type tumble dryers. These appliances may use flammable refrigerants. Additional requirements for these appliances are given in normative Annex AA.
Appliances not intended for normal household use but which nevertheless can be a source of danger to the public, such as appliances intended to be used by laymen in shops, in light industry and on farms are within the scope of this standard.
Examples of such appliances are tumble dryers for communal use in blocks of flats or in launderettes.
As far as is practicable, this standard deals with the common hazards presented by appliances that are encountered by all persons.
However, in general, it does not take into account - persons (including children) whose - physical, sensory or mental capabilities; or - lack of experience and knowledge prevents them from using the appliance safely without supervision or instruction; - children playing with the appliance.
Attention is drawn to the fact that - for appliances intended to be used in vehicles or on board ships or aircraft, additional requirements can be necessary; - in many countries, additional requirements are specified by the national health authorities, the national authorities responsible for the protection of labour, the national water supply authorities.
This standard does not apply to - appliances intended exclusively for industrial purposes; - appliances intended to be used in locations where special conditions prevail, such as the presence of a corrosive or explosive atmosphere (dust, vapour or gas); - appliances incorporating steam generating devices in which steam is produced at a pressure exceeding 50 kPa.
oSIST prEN IEC 60335-2-11:2026
2 Normative references
This clause of Part 1 is applicable except as follows.
Addition:
IEC 60068-2-6, Environmental testing – Part 2: Tests – Test Fc: Vibration (sinusoidal) IEC 60079 (all parts), Explosive atmospheres IEC 60079-7:2015, Explosive atmospheres – Part 7: Equipment protection by increased safety "e" 1) IEC 60079-7:2015/AMD1:2017 IEC 60079-15:2017, Explosive atmospheres – Part 15: Equipment protection by type of protection "n" IEC 60335-2-34:2021, Household and similar electrical appliances – Safety – Part 2-34:
Particular requirements for motor-compressors IEC 60584-1, Thermocouples – Part 1: EMF specifications and tolerances ISO 817, Refrigerants – Designation and safety classification ISO 7010:2019, Graphical symbols – Safety colours and safety signs – Registered safety signs
3 Terms and definitions
This clause of Part 1 is applicable except as follows.
3.1 Definitions relating to physical characteristics
3.1.9 Modification:
Replace the first paragraph with the following:
operation of the appliance under the following conditions:
The appliance is operated filled with textile material having a mass in the dry condition equal to the maximum load stated in the instructions.
The textile material consists of pre-washed double-hemmed cotton sheets having dimensions 2 2 and 175 g/m in the dry approximately 70 cm × 70 cm and a specific mass between 140 g/m condition. The textile material is soaked with water having a temperature of 25 °C ± 5 °C and a mass equal to that of the textile material.
If the drying function can automatically follow the washing function in a washing machine, the appliance is not separately loaded. The appliance is operated with the maximum quantity of textile material stated in the instructions for the combined washing-drying cycle. Note 101 to entry: Cotton having a water content not exceeding 10 % is considered to be in the dry condition. Cotton conditioned for 24 h in still air, having a temperature of 20 °C ± 2 °C, a relative humidity between 60 % and 70 % and a pressure between 860 mbar and 1 060 mbar, will contain approximately 7 % water.
1) There exists a consolidated edition 5.1:2017 that includes IEC 60079-7:2015 and its Amendment 1:2017.
oSIST prEN IEC 60335-2-11:2026
A steam generator intended to be filled by hand is filled according to the instructions, water being added to maintain the steam generation.
A steam generator intended to be filled automatically is connected to the water mains.
3.5 Definitions relating to types of appliances
3.5.101 tumble dryer appliance in which textile material is dried by tumbling in a rotating drum through which heated air is blown 3.5.102 condensation-type tumble dryer tumble dryer in which the air used for the drying process is dehumidified by passing over an ambient heat exchanger and then recirculated through the load in a closed loop system Note 1 to entry: A condensation-type tumble dryer is based on resistive heating element(s). 3.5.103 heat pump type tumble dryer tumble dryer that uses a refrigerating system incorporating sealed motor-compressors for carrying out the drying process Note 1 to entry: A heat pump type tumble dryer can contain resistive heating element(s).
3.6 Definitions relating to parts of an appliance
3.6.101 steam generator device in which steam is produced at a pressure not exceeding 50 kPa and in which the pressure drops to atmospheric pressure when the steam is not supplied
3.8 Definitions relating to miscellaneous matters
3.8.101 cool down period final part of the tumble dryer cycle where the drum is continuously rotated with reduced power to the heating element and with air circulation in order to reduce the possibility of spontaneous combustion of the clothes load Note 1 to entry: Continuous rotation does not mean rotation in same direction if the intended operation is to reverse direction in normal use.
3.8.102 cheesecloth
bleached cotton cloth running approximately 34 g/m with a thread count in the range of 10 to 13 threads/cm by 9 to 12 threads/cm 3.8.103 flammable refrigerant refrigerant with a flammability classification A2L, A2 or A3 in accordance with ISO 817 Note 1 to entry: For refrigerant blends that have more than one flammability classification, the most unfavourable classification is taken for the purposes of this definition.
4 General requirement
This clause of Part 1 is applicable.
oSIST prEN IEC 60335-2-11:2026
5 General conditions for the tests
This clause of Part 1 is applicable.
6 Classification
This clause of Part 1 is applicable except as follows.
6.2 Addition:
Appliances shall be at least IPX4.
7 Marking and instructions
This clause of Part 1 is applicable except as follows.
7.1 Addition:
The appliance shall be marked with symbol ISO 7000-0790 (2004-01) or with the substance of the following:
Read the instructions 7.10 Addition:
If the off position is only indicated by letters, the word "off" shall be used. 7.12 Addition:
The instructions shall state:
- the maximum mass of dry textile material in kilograms to be used in the appliance;
- that the tumble dryer is not to be used if industrial chemicals have been used for cleaning;
- that the lint trap must be cleaned frequently, if applicable;
- that lint must not to be allowed to accumulate around the tumble dryer (not applicable for appliances intended to be vented to the exterior of the building);
- that adequate ventilation must be provided to avoid the back flow of gases into the room from appliances burning other fuels, including open fires (this instruction is not required if the tumble dryer discharges the air into the room).
If symbol ISO 7000-0790 (2004-01) is used, its meaning shall be explained. The instructions shall include the substance of the following:
- Do not dry unwashed items in the tumble dryer.
- Items that have been soiled with substances such as cooking oil, acetone, alcohol, petrol, kerosene, spot removers, turpentine, waxes and wax removers should be washed in hot water with an extra amount of detergent before being dried in the tumble dryer.
- Items such as foam rubber (latex foam), shower caps, waterproof textiles, rubber backed articles and clothes or pillows fitted with foam rubber pads should not be dried in the tumble dryer.
- Fabric softeners, or similar products, should be used as specified by the fabric softener instructions.
- Remove all objects from pockets such as lighters and matches.
oSIST prEN IEC 60335-2-11:2026
- Fill steam generators only with liquids specified by the manufacturer. The instructions shall include the substance of the following warning:
WARNING: Never stop a tumble dryer before the end of the drying cycle unless all items are quickly removed and spread out so that the heat is dissipated. The instructions for appliances for which the air temperature measured according to 11.8 exceeds 55 °C during the drying cycle shall include the substance of the following warning:
WARNING: The appliance must not be supplied through an external switching device, such as a timer, or connected to a circuit that is regularly switched on and off by a utility. 7.12.1 Addition:
The instructions shall state that:
- for appliances with ventilation openings in the base, a carpet must not obstruct the openings;
- exhaust air must not be discharged into a flue that is used for exhausting fumes from appliances burning gas or other fuels (this instruction is not required if the tumble dryer discharges the air into the room);
- the appliance must not be installed behind a lockable door, a sliding door or a door with a hinge on the opposite side to that of the tumble dryer, in such a way that a full opening of the tumble dryer door is restricted.
If the instructions state that the tumble dryer can be placed on top of a washing machine, they shall state which washing machines are suitable. Instructions shall be given for the assembly of the tumble dryer and washing machine. The instructions shall state how to obtain any fixing attachments required, unless they are supplied with the appliance. 7.14 Addition:
The height of symbol ISO 7000-0790 (2004-01) shall be at least 15 mm. 7.15 Addition:
Symbol ISO 7000-0790 (2004-01), or the marking "Read the instructions", shall be readily visible when the appliance is installed as in normal use.
8 Protection against access to live parts
This clause of Part 1 is applicable except as follows.
8.1.1 Addition:
For parts of appliances situated not more than 850 mm above the floor after installation or in normal use, in addition to the use of test probe 18, test probe 19 of IEC 61032 is also applied. wherever test probe 18 is used and with the same test conditions used for test probe 18. Test probe 19 is not applied to appliances for communal use in blocks of flats, in launderettes.
9 Starting of motor-operated appliances
This clause of Part 1 is not applicable.
oSIST prEN IEC 60335-2-11:2026
10 Power input and current
This clause of Part 1 is applicable.
11 Heating
This clause of Part 1 is applicable except as follows.
11.2 Addition:
Lint traps are cleaned and then 50 % of the area of the filter is blocked. 11.3 Addition:
Where the external accessible surfaces are suitably flat and access permits, then the test probe of Figure 101 is used to measure the temperature rises of external accessible surfaces specified in Table 101. The probe is applied with a force of 4 N ± 1 N to the surface in such a way that the best possible contact between the probe and the surface is ensured. The measurement is performed after a contact period of 30 s.
The probe may be held in place using a laboratory stand clamp or similar device. Any measuring instrument giving the same results as the probe may be used.
11.7 Modification:
Replace the first paragraph with the following:
Appliances incorporating a timer, a humidity sensing control or other time-limiting control are operated in cycles. Each cycle comprises an operating period having a duration equal to the maximum time that can be provided by the control and a rest period of 4 min during which the appliance is reloaded.
The test may be ended if the temperature rise of any part does not exceed the value determined during the preceding cycle by more than 8 K.
Appliances having a combined washing-drying cycle are operated with the drying programme resulting in the highest temperature rise.
Appliances with a steam generator are operated with that steam mode resulting in the highest temperature rise.
Other appliances are operated continuously until steady conditions are established. 11.8 Modification:
Replace the first paragraph with the following:
During the test, the temperature rises are monitored continuously and shall not exceed the values shown in Table 3 and Table 101.
Addition:
The temperature rises are measured with the door closed.
oSIST prEN IEC 60335-2-11:2026
The exhaust temperature of the air from the drum, measured at the first lint filter after the air passes the clothes load, shall be measured for the purposes of 22.105. Table 101 – Maximum temperature rises for accessible external surfaces under normal operating conditions with the door closed a Temperature rise K
Surface Surfaces of appliances situated not more than Surfaces situated more 850 mm above the floor after installation than 850 mm above the b floor after installation b Front surfaces Other surfaces Bare metal 38 42 42
Coated metal 42 49 49 Glass and ceramic 51 56 56 Plastic and plastic 58 62 62 d, e coating > 0,4 mm NOTE The temperature rise limits of handles, knobs, grips, keyboards, keypads and similar parts are specified in Table 3.
a Temperature rises are not measured on:
- the underside of appliances intended to be used on a working surface or floor where these surfaces are inaccessible to a 75 mm diameter probe having a hemispherical end;
- the rear surface of appliances where these surfaces are inaccessible to a 75 mm diameter probe having a hemispherical end.
b If these values are exceeded, the test is allowed to be repeated with the appliance moved away from the test corner side wall. The test is repeated for 1 cycle.
Metal is considered coated when a coating having a minimum thickness of 90 μm made of enamel, powder or non-substantially plastic coating is used.
d The temperature rise limit applies also for plastic material having a metal finish of thickness less than 0,1 mm.
e When the thickness of plastic coating does not exceed 0,4 mm, the temperature rise limits of coated metal or glass and ceramic apply.
12 Charging of metal-ion batteries
This clause of Part 1 is applicable
13 Leakage current and electric strength at operating temperature
This clause of Part 1 is applicable except as follows.
13.2 Modification:
Replace the last two dashed items in the eighth paragraph with the following:
- for stationary class I appliances 3,5 mA, or 1 mA per kW of rated power input with a maximum of 5 mA, whichever is higher
14 Transient overvoltages
This clause of Part 1 is applicable.
oSIST prEN IEC 60335-2-11:2026
15 Moisture resistance
This clause of Part 1 is applicable except as follows.
15.2 Addition:
The test is carried out with the drum filled with wet textile material as specified for normal operation, the mass of the water, however, being approximately 1,5 times the mass of the dry textile material.
Appliances intended to be connected to the water mains are operated with the outlet of the condensation circuit blocked. The inlet valve is held open and the filling continued for 1 min after first evidence of overflow or for 5 min after a protective device operates to stop the flow. Doors are opened but interlocks are not forced.
...