Abstract

This document specifies a general method of test for determining the pH value of an aqueous suspension of a sample of pigment or extender.

Status
Not Published
Public Enquiry End Date
01-Jun-2026
Technical Committee
PIP - Pigments and extenders
Current Stage
5020 - Formal vote (FV) (Adopted Project)
Start Date
02-Nov-2026
Due Date
21-Dec-2026
Completion Date
17-Nov-2026

Buy Documents

Draft

oSIST prEN ISO 787-9:2026

English language (7 pages)
Preview
Preview
e-Library read for
×1 day

kSIST FprEN ISO 787-9:2026 is a general test method for pigments and extenders published by SIST as the Slovenian adoption of the ISO draft on pH determination. It specifies how to measure the pH value of an aqueous suspension of a pigment or extender sample, so laboratories can compare results on the same basis.

What does kSIST FprEN ISO 787-9:2026 specify?

kSIST FprEN ISO 787-9:2026 specifies a laboratory method for determining the pH value of an aqueous suspension made from a sample of pigment or extender. It is a test method document, not a product specification.

The document is organized into:

  • Scope
  • Normative references
  • Terms and definitions
  • Reagents
  • Apparatus
  • Sampling
  • Procedure
  • Expression of results
  • Test report

That structure matters in practice because it shows the full workflow: choose the right sample, prepare the suspension, measure pH, then report the result in a consistent way.

What are the key requirements of kSIST FprEN ISO 787-9:2026?

The method depends on controlled water quality, careful sample preparation and calibrated pH measurement. The main points in Clauses 4 to 9 are the practical steps that determine whether results are comparable.

Reagents and measuring setup

Clause 4 requires distilled or demineralized water of at least grade 3 from ISO 3696, with a pH between 5,0 and 7,5, and protected from atmospheric carbon dioxide. Clause 4 also gives an optional ion intensity regulating solution, 0,1 % KCl, prepared with that water. In practice, this reduces variation in the suspension and helps make readings more stable.

Clause 5 requires a chemically resistant glass container, a pH measuring device readable to 0,1 unit and calibrated at the test temperature, and a balance with suitable error limit. This means the result depends not only on the sample but also on clean, suitable equipment and calibration at the right temperature.

Sampling and suspension preparation

Clause 6 requires a representative sample taken in accordance with ISO 15528. That matters because pH can vary if the sample is not representative of the batch.

Clause 7 requires the test to be carried out at room temperature and the sample to be made into a 5 % to 10 % mass fraction suspension with water or the ion intensity regulating solution. The suspension is then shaken, rolled or stirred vigorously, left for 5 min, and measured to the nearest 0,1 unit. The document also allows filtering the suspension before measurement, if needed.

Wetting agent and reporting

Clause 7 allows a wetting agent when the product does not disperse easily in water. Pure ethanol or methanol may be used up to 10 % by volume of the suspension, but the minimum quantity should be used and the neutrality of the wetting agent checked by a blank determination. The water volume is adjusted so the original suspension concentration stays the same. In practice, this keeps difficult-to-disperse pigments measurable without changing the meaning of the result.

Clause 8 requires the result to be reported to the nearest 0,1 unit. Clause 9 requires the report to include the product identification, the reference to ISO 787-9, the suspension concentration and liquid used, any filtration method, any wetting agent used, the result, the test temperature, deviations, anomalies and the test date.

What terms does kSIST FprEN ISO 787-9:2026 use?

The document uses the terminology of ISO 18451-1 for pigments, dyestuffs and extenders. A few terms are especially important for reading and applying the method:

  • pH value - the measured acidity or alkalinity of the aqueous suspension.
  • Aqueous suspension - a mix of the sample in water, or in the ion intensity regulating solution, prepared for measurement.
  • Ion intensity regulating solution - the optional 0,1 % KCl solution used to improve measurement consistency.
  • Wetting agent - an additive used when the sample does not disperse easily in water.
  • Representative sample - a sample taken so it reflects the product being tested.
  • Mass fraction - the concentration basis used for the 5 % to 10 % suspension.

Who uses kSIST FprEN ISO 787-9:2026?

kSIST FprEN ISO 787-9:2026 is used by laboratories testing pigments and extenders, including quality control and quality assurance teams in manufacturers’ plants. It is also relevant to buyers, specification writers and third-party test labs that need a common way to compare pH results on pigment or extender suspensions.

What changed in kSIST FprEN ISO 787-9:2026 from the previous edition?

kSIST FprEN ISO 787-9:2026 replaces ISO 787-9:2019 and is described as a technical revision. The stated changes are:

  • updated normative references
  • revised wording for distilled or demineralized water in 4.1
  • replacement of “buffer solution” with “ion intensity regulating solution” in 4.2
  • changed quantity of added wetting agent in Clause 7
  • updated information required in the test report in Clause 9

Which standards are used with kSIST FprEN ISO 787-9:2026?

kSIST FprEN ISO 787-9:2026 refers to three standards that support the method:

  • ISO 3696 - specifies the quality of the water used for the suspension.
  • ISO 15528 - gives the sampling method for obtaining a representative test sample.
  • ISO 18451-1 - provides the terminology used for pigments, dyestuffs and extenders.

What does the kSIST FprEN ISO 787-9:2026 document contain?

The document contains the full test method for pH measurement of pigment and extender suspensions, including reagent requirements, apparatus, sampling, procedure, result expression and reporting. It also gives the practical details needed to run the test consistently, such as suspension concentration, standing time, measurement precision and optional use of a wetting agent.

It does not present product specifications or acceptance limits. Its value is in the test setup and reporting rules that let different laboratories obtain comparable pH results for the same material.

Relations

Effective Date
01-May-2026

Buy Documents

Draft

oSIST prEN ISO 787-9:2026

English language (7 pages)
Preview
Preview
e-Library read for
×1 day

Frequently Asked Questions

kSIST FprEN ISO 787-9:2026 is a draft published by the Slovenian Institute for Standardization (SIST). Its full title is "General methods of test for pigments and extenders - Part 9: Determination of pH value of an aqueous suspension (ISO/FDIS 787-9:2026)". This standard covers: This document specifies a general method of test for determining the pH value of an aqueous suspension of a sample of pigment or extender.

This document specifies a general method of test for determining the pH value of an aqueous suspension of a sample of pigment or extender.

kSIST FprEN ISO 787-9:2026 is classified under the following ICS (International Classification for Standards) categories: 87.060.10 - Pigments and extenders. The ICS classification helps identify the subject area and facilitates finding related standards.

kSIST FprEN ISO 787-9:2026 has the following relationships with other standards: It is inter standard links to SIST EN ISO 787-9:2019. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.

kSIST FprEN ISO 787-9:2026 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.

Standards Content (Sample)

Contents

  • 1 Scope
  • 2 Normative references
  • 3 Terms and definitions
  • 4 Reagents
  • 5 Apparatus
  • 6 Sampling
  • 7 Procedure
  • 8 Expression of results
  • 9 Test report

1 Scope

This document specifies a general method of test for determining the pH value of an aqueous suspension of a sample of pigment or extender.

2 Normative references

The following documents are referred to in the text in such a way that some or all of their content constitutes requirements of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. ISO 3696, Water for analytical laboratory use — Specification and test methods ISO 15528, Paints, varnishes and raw materials for paints and varnishes — Sampling ISO 18451-1, Pigments, dyestuffs and extenders — Terminology — Part 1: General terms

3 Terms and definitions

For the purposes of this document, the terms and definitions given in ISO 18451-1 apply. ISO and IEC maintain terminology databases for use in standardization at the following addresses:

  • ISO Online browsing platform: available at https:// www .iso .org/ obp
  • IEC Electropedia: available at https:// www .electropedia .org/

4 Reagents

4.1 Distilled or demineralized water, of at least grade 3 as specified in ISO 3696, having a pH between 5,0 and 7,5.

Because water rapidly absorbs carbon dioxide, the water shall be protected from access to the atmosphere. ®1) 4.2 Ion intensity regulating solution, 0,1 % KCl (p.a.), CAS Registry Number 7447-40-7, prepared using water specified in 4.1.

...