SIST IEC 60652:1995
(Main)Loading tests on overhead line structures
Loading tests on overhead line structures
Applicable to testing of towers and structures of overhead lines for voltages above 45 kV. Codifies methods of tests.
Essais mécaniques des structures de lignes aériennes
Applicable aux essais de pylônes et structures des lignes aériennes pour tensions supérieures à 45 kV. Codifie les méthodes d'essai.
Preskusi obremenitev konstrukcij nadzemnih vodov
General Information
- Status
- Withdrawn
- Publication Date
- 31-Jul-1995
- Withdrawal Date
- 19-Oct-2009
- Technical Committee
- NVV - Overhead lines and overhead electrical conductors
- Current Stage
- 9900 - Withdrawal (Adopted Project)
- Start Date
- 06-Oct-2009
- Due Date
- 29-Oct-2009
- Completion Date
- 20-Oct-2009
Relations
- Effective Date
- 01-Nov-2009
Overview
SIST IEC 60652:1995 is an international standard established by the International Electrotechnical Commission (IEC) that specifies the procedures for loading tests on overhead line structures, such as towers and supporting frameworks. This standard applies specifically to overhead lines with voltages above 45 kV, providing a clear methodology to evaluate the mechanical strength and reliability of power transmission structures under various load conditions.
The standard ensures consistent and safe design verification processes for electrical utilities and manufacturers, helping to maintain structural integrity and operational safety in power transmission and distribution networks.
Key Topics
Scope and Applicability
SIST IEC 60652:1995 focuses on overhead line towers and structures used in high-voltage electrical transmission systems – particularly those operating above 45 kV. It codifies how to conduct mechanical loading tests to assess their performance and durability.Testing Procedures
The standard outlines standardized methods for applying mechanical loads simulating operational stresses such as wind pressure, ice accumulation, and conductor tension. These tests verify the structural capability to withstand extreme environmental conditions.Load Types and Conditions
Includes criteria for static and dynamic loading tests, ensuring towers and support structures meet design requirements without failure or excessive deformation.Safety and Compliance
SIST IEC 60652:1995 promotes safe testing environments and compliance with regulatory frameworks, reducing the risk of structural failure and enhancing grid reliability.
Applications
Overhead Power Line Design Verification
Engineers use SIST IEC 60652:1995 tests to validate design assumptions and confirm that towers will perform reliably under expected service conditions.Quality Control for Manufacturers
Manufacturers implement these tests as part of quality assurance protocols to certify that new overhead line structures meet international performance standards.Infrastructure Maintenance and Assessment
Utilities apply loading tests during maintenance cycles to assess aging structures, identify potential weaknesses, and prioritize repairs or replacements.Research and Development
The standard provides a baseline for testing innovative materials and designs in overhead line construction, facilitating advances in power transmission technology.
Related Standards
- IEC 60826 – Design criteria for overhead lines, which complements mechanical testing by defining load calculation methods.
- IEC 61323 – Testing guidelines for overhead line conductors.
- IEC 61936-1 – Requirements for electrical installations exceeding 1 kV AC.
- ISO 9001 – Quality management systems, often integrated with SIST IEC 60652:1995 for comprehensive manufacturing control.
By adhering to the SIST IEC 60652:1995 standard, stakeholders in the power transmission industry can ensure overhead line structures meet rigorous mechanical performance criteria - enhancing safety, durability, and reliability in high-voltage electrical networks. Keywords: overhead line loading tests, SIST IEC 60652:1995, high voltage line structure testing, mechanical loading, power transmission safety.
Frequently Asked Questions
SIST IEC 60652:1995 is a standard published by the Slovenian Institute for Standardization (SIST). Its full title is "Loading tests on overhead line structures". This standard covers: Applicable to testing of towers and structures of overhead lines for voltages above 45 kV. Codifies methods of tests.
Applicable to testing of towers and structures of overhead lines for voltages above 45 kV. Codifies methods of tests.
SIST IEC 60652:1995 is classified under the following ICS (International Classification for Standards) categories: 29.240.20 - Power transmission and distribution lines. The ICS classification helps identify the subject area and facilitates finding related standards.
SIST IEC 60652:1995 has the following relationships with other standards: It is inter standard links to SIST EN 60652:2005. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
You can purchase SIST IEC 60652:1995 directly from iTeh Standards. The document is available in PDF format and is delivered instantly after payment. Add the standard to your cart and complete the secure checkout process. iTeh Standards is an authorized distributor of SIST standards.
Standards Content (Sample)
SLOVENSKI STANDARD
01-avgust-1995
Preskusi obremenitev konstrukcij nadzemnih vodov
Loading tests on overhead line structures
Essais mécaniques des structures de lignes aériennes
Ta slovenski standard je istoveten z: IEC 60652
ICS:
29.240.20 Daljnovodi Power transmission and
distribution lines
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
-
...










Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.
Loading comments...