Plastics piping systems - Non pressure soil and waste discharge piping components within the building structure - Requirements and test/assessment methods for pipes and fittings

This European Standard specifies requirements for non-pressure plastics pipes and fittings for soil and waste applications.
It is intended to be used in soil and waste discharge applications:
- inside the building (application area code "B"),
- buried in ground within the building structure (application area code "BD") and with a diameter greater than or equal to 75 mm
It gives the associated test/assessment methods.
This standard does not cover adhesives, joint sealings and gaskets
NOTE      For this standard, the term fitting includes the term joint as meant by mandate M131.

Kunststoff-Rohrleitungssysteme - Drucklose Rohrleitungssysteme zum Ableiten von Abwasser innerhalb der Gebäudestruktur - Anforderungen und Prüf-/Bewertungsverfahren für Rohre und Formstücke

Diese Europäische Norm legt Anforderungen für Rohre und Formstücke aus Kunststoff für drucklose Rohr-leitungs¬systeme zum Ableiten von Abwasser fest.
Sie gilt für Abwasseranwendungen:
-   innerhalb von Gebäuden (Anwendungskennzeichen „B“);
-   erdverlegt innerhalb der Gebäudestruktur (Anwendungskennzeichen „BD“) mit einem Durchmesser  75 mm.
Sie enthält die erforderlichen Prüf-/Bewertungsverfahren.
Diese Norm gilt nicht für Klebstoffe, Abdichtungen von Verbindungen und Dichtungen.
ANMERKUNG   Für die Anwendung dieser Norm beinhaltet der Begriff „Formstück“ den Begriff „Verbindung“ im Sinne von Mandat M131.

Systèmes de canalisations en plastique - Composants de canalisations pour l'évacuation des eaux-vannes et des eaux usées à l'intérieur de la structure des bâtiments - Exigences et méthodes d'essai/d'évaluation pour tubes et raccords

La présente Norme européenne spécifie les exigences relatives aux tubes et raccords en plastique, sans pression, destinés aux applications pour eaux-vannes et eaux usées.
Elle est destinée aux applications d’évacuation des eaux-vannes et des eaux usées :
-   à l'intérieur du bâtiment (code de zone d'application « B ») .
-   enterrées dans la structure du bâtiment (code de zone d'application « BD ») et de diamètre supérieur ou égal à 75 mm.
Elle indique les méthodes d’essai/d’évaluation associées.
La présente norme ne couvre pas les adhésifs, les garnitures de joints et les joints d’étanchéité.
NOTE   Pour la présente norme, le terme « raccord » inclut le terme « joint » au sens donné par le mandat M/131.

Cevni sistemi iz polimernih materialov - Odvodne cevne komponente brez tlaka v zgradbah - Zahteve in preskusi/metode ocenjevanja za cevi in fitinge

General Information

Status
Not Published
Public Enquiry End Date
14-Jun-2011
Current Stage
98 - Abandoned project (Adopted Project)
Start Date
22-Oct-2012
Due Date
27-Oct-2012
Completion Date
22-Oct-2012

Relations

Buy Standard

Draft
prEN 15012:2011
English language
30 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

SLOVENSKI STANDARD
oSIST prEN 15012:2011
01-junij-2011
Cevni sistemi iz polimernih materialov - Odvodne cevne komponente brez tlaka v
zgradbah - Zahteve in preskusi/metode ocenjevanja za cevi in fitinge
Plastics piping systems - Non pressure soil and waste discharge piping components
within the building structure - Requirements and test/assessment methods for pipes and
fittings
Kunststoff-Rohrleitungssysteme - Drucklose Rohrleitungssysteme zum Ableiten von
Abwasser innerhalb der Gebäudestruktur - Anforderungen und Prüf
-/Bewertungsverfahren für Rohre und Formstücke
Systèmes de canalisations en plastique - Composants de canalisations pour l'évacuation
des eaux-vannes et des eaux usées à l'intérieur de la structure des bâtiments -
Exigences et méthodes d'essai/d'évaluation pour tubes et raccords
Ta slovenski standard je istoveten z: prEN 15012
ICS:
23.040.20 Cevi iz polimernih materialov Plastics pipes
23.040.45 Fitingi iz polimernih Plastics fittings
materialov
91.140.80 Drenažni sistemi Drainage systems
oSIST prEN 15012:2011 en,fr,de
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------
oSIST prEN 15012:2011

---------------------- Page: 2 ----------------------
oSIST prEN 15012:2011


EUROPEAN STANDARD
DRAFT
prEN 15012
NORME EUROPÉENNE

EUROPÄISCHE NORM

March 2011
ICS 91.140.80 Will supersede EN 15012:2007
English Version
Plastics piping systems - Non pressure soil and waste discharge
piping components within the building structure - Requirements
and test/assessment methods for pipes and fittings
Systèmes de canalisations en plastique - Composants de Kunststoff-Rohrleitungssysteme - Drucklose
canalisations pour l'évacuation des eaux-vannes et des Rohrleitungssysteme zum Ableiten von Abwasser innerhalb
eaux usées à l'intérieur de la structure des bâtiments - der Gebäudestruktur - Anforderungen und Prüf-
Exigences et méthodes d'essai/d'évaluation pour tubes et /Bewertungsverfahren für Rohre und Formstücke
raccords
This draft European Standard is submitted to CEN members for enquiry. It has been drawn up by the Technical Committee CEN/TC 155.

If this draft becomes a European Standard, CEN members are bound to comply with the CEN/CENELEC Internal Regulations which
stipulate the conditions for giving this European Standard the status of a national standard without any alteration.

This draft European Standard was established by CEN in three official versions (English, French, German). A version in any other language
made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management
Centre has the same status as the official versions.

CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia,
Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland,
Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom.

Recipients of this draft are invited to submit, with their comments, notification of any relevant patent rights of which they are aware and to
provide supporting documentation.

Warning : This document is not a European Standard. It is distributed for review and comments. It is subject to change without notice and
shall not be referred to as a European Standard.


EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION

EUROPÄISCHES KOMITEE FÜR NORMUNG

Management Centre: Avenue Marnix 17, B-1000 Brussels
© 2011 CEN All rights of exploitation in any form and by any means reserved Ref. No. prEN 15012:2011: E
worldwide for CEN national Members.

---------------------- Page: 3 ----------------------
oSIST prEN 15012:2011
prEN 15012:2011 (E)
Contents Page
Foreword . 3
Introduction . 3
1 Scope . 4
2 Normative references . 4
3 Terms, definitions and symbols . 5
4 Requirements . 6
4.1 Reaction to fire . 6
4.2 Maximum load for admissible deformation for pipes and fittings for applications buried in
ground within the building structure . 6
4.3 Dimensional tolerances . 6
4.4 Tightness . 8
4.5 Durability . 8
4.6 Release of dangerous substances . 8
5 Test methods . 8
5.1 Reaction to fire of pipes and fittings . 8
5.2 Maximum load for admissible deformation . 8
5.3 Dimensional tolerances . 9
5.4 Tightness . 9
5.5 Durability . 9
6 Evaluation of conformity . 10
6.1 General . 10
6.2 Initial type testing – Type testing . 10
6.3 Factory production control (FPC) . 13
Annex A (informative) Product standards for soil and waste discharge piping systems in plastics
materials . 19
Annex B (informative) Standards for assessment of conformity for soil and waste discharge
piping systems in plastics materials . 20
Annex ZA (informative) Clauses of this European Standard addressing the provisions of EU
Construction Products Directive . 21
ZA.1. Scope and relevant characteristics . 21
ZA.2. Procedure for attestation of conformity of plastics pipes and fittings . 23
ZA.2.1. System of attestation of conformity . 23
ZA.2.2. EC Certificate and Declaration of conformity . 25
ZA.3. CE marking and labelling . 26
ZA.3.1. CE marking requirements . 26
Bibliography . 30

2

---------------------- Page: 4 ----------------------
oSIST prEN 15012:2011
prEN 15012:2011 (E)
Foreword
This document (prEN 15012:2011) has been prepared by Technical Committee CEN/TC 155 “Plastics piping
systems and ducting systems”, the secretariat of which is held by NEN.
This document is currently submitted to the CEN Enquiry.
This document has been prepared under Mandate M/131 "Pipes, tanks and ancillaries not in contact with
water intended for human consumption" given to CEN by the European Commission and the European Free
Trade Association and supports essential requirements of EU Directives.
For the relationship with EU Directives, see informative Annex ZA, which is an integral part of this document.
According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following
countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Cyprus, Czech,
Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia,
Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain,
Sweden, Switzerland and United Kingdom.
Introduction
This European Standard specifies only those characteristics of pipes and fittings for soil and waste
applications inside buildings or buried in ground within the building structure, that need to be known to
determine if the works in which these are to be installed can satisfy the essential requirements of the EU
Directive(s). Additional characteristics are specified in the documents listed in Annex A or in other appropriate
product specifications.
3

---------------------- Page: 5 ----------------------
oSIST prEN 15012:2011
prEN 15012:2011 (E)
1 Scope
This European Standard specifies requirements for non-pressure plastics pipes and fittings for soil and waste
applications.
It is intended to be used in soil and waste discharge applications:
 inside the building (application area code "B"),
 buried in ground within the building structure (application area code "BD") and with a diameter greater
than or equal to 75 mm

It gives the associated test/assessment methods.
This standard does not cover adhesives, joint sealings and gaskets
NOTE For this standard, the term fitting includes the term joint as meant by mandate M131.
2 Normative references
The following referenced documents are indispensable for the application of this document. For dated
references, only the edition cited applies. For undated references, the latest edition of the referenced
document (including any amendments) applies.
EN 681-1, Elastomeric seals — Materials requirements for pipe joint seals used in water and drainage
applications — Part 1: Vulcanised rubber
EN 681-2, Elastomeric seals — Materials requirements for pipe joint seals used in water and drainage
applications — Part 2: Thermoplastic elastomers
EN 681-3, Elastomeric seals — Materials requirements for pipe joint seals used in water and drainage
applications — Part 3: Cellular materials of vulcanised rubber
EN 681-4, Elastomeric seals — Materials requirements for pipe joint seals used in water and drainage
applications — Part 4: Cast polyurethane sealing elements
EN 727, Plastics piping and ducting systems — Thermoplastics pipes and fittings — Determination of vicat
softening temperature (VST)
EN 728, Plastics piping and ducting systems — Polyolefin pipes and fittings — Determination of oxidation
induction time
EN 1053, Plastics piping systems — Thermoplastics piping systems for non-pressure applications — Test
method for watertightness
EN 1054, Plastics piping systems — Thermoplastics piping systems for soil and waste discharge — Test
method for airtightness of joints
EN 1055, Plastics piping systems — Thermoplastics piping systems for soil and waste discharge inside
buildings — Test method for resistance to elevated temperature cycling
EN 1329-1, Plastics piping systems for soil and waste discharge (low and high temperature) within the
building structure — Unplasticized poly(vinyl chloride) (PVC-U) — Part 1: Specifications for pipes, fittings and
the system
EN 1451-1, Plastics piping systems for soil and waste discharge (low and high temperature) within the
building structure — Polypropylene (PP) — Part 1: Specifications for pipes, fittings and the system
4

---------------------- Page: 6 ----------------------
oSIST prEN 15012:2011
prEN 15012:2011 (E)
EN 1455-1, Plastics piping systems for soil and waste discharge (low and high temperature) within the
building structure — Acrylonitrile-butadiene-styrene (ABS) — Part 1: Requirements for pipes, fittings and the
system
EN 1519-1, Plastics piping systems for soil and waste discharge (low and high temperature) within the
building structure — Polyethylene (PE) — Part 1: Specifications for pipes, fittings and the system
EN 1565-1, Plastics piping systems for soil and waste discharge (low and high temperature) within the
building structure — Styrene copolymer blends (SAN+PVC) — Part 1: Specifications for pipes, fittings and the
system
EN 1566-1, Plastics piping systems for soil and waste discharge (low and high temperature) within the
building structure — Chlorinated poly(vinyl chloride) (PVC-C) — Part 1: Specifications for pipes, fittings and
the system
EN 13501-1, Fire classification of construction products and building elements — Part 1: Classification using
test data from reaction to fire tests
EN 13823, Reaction to fire tests for building products — Building products excluding floorings exposed to the
thermal attack by a single burning item
EN 16000, Plastics piping systems — Systems within the building structure — Mounting and fixing of
components in the test apparatus to thermal attack by a single burning item
EN ISO 3126, Plastics piping systems — Plastics components — Determination of dimensions
(ISO 3126:2005)
EN ISO 9969, Thermoplastics pipes — Determination of ring stiffness (ISO 9969:2007)
EN ISO 13967, Thermoplastics fittings — Determination of ring stiffness (ISO 13967:2009)
ISO 1133, Plastics — Determination of the melt mass-flow rate (MFR) and the melt volume-flow rate (MVR) of
thermoplastics
ISO 13966, Thermoplastics pipes and fittings — Nominal ring stiffnesses
3 Terms, definitions and symbols
For the purposes of this document, the following terms, definitions and symbols apply.
3.1
nominal size (DN)
numerical designation of the size of a component, other than a component designated by thread size, which is
a convenient round number approximately equal to the manufacturing dimension, in millimetres (mm)
NOTE This can apply to either the internal diameter (DN/ID) or external diameter (DN/OD)
3.2
nominal outside diameter
d
n
specified outside diameter, in millimetres, assigned to a nominal size
3.3
nominal ring stiffness
SN
numerical designation of the ring stiffness of a pipe or fitting, which is a convenient round number indicating
the minimum required ring stiffness of the pipe or fitting
5

---------------------- Page: 7 ----------------------
oSIST prEN 15012:2011
prEN 15012:2011 (E)
NOTE It is designated by the letters "SN" followed by the appropriate number.
3.4
Connection
assembly of pipe(s) and fitting(s).
4 Requirements
4.1 Reaction to fire
The contribution to fire development of products falling under the scope of this European standard is verified
according to the provisions of clause 5.1.
Test results shall be classified according to EN 13501-1.
4.2 Maximum load for admissible deformation for pipes and fittings for applications buried
in ground within the building structure
4.2.1 General
This clause is only applicable for components intended to be used buried in ground within the building
structure and with a nominal outside diameter greater than or equal to 75 mm.
For the intended end use buried in ground within the building structure, the maximum load for admissible
deformation shall be addressed as ring stiffness.
Ring stiffness shall be determined either by calculation or as described in 4.2.2 and 4.2.3.
4.2.2 Ring stiffness of pipes
The ring stiffness of a thermoplastics pipe shall be determined in accordance with 5.2.1 and shall be
expressed either as SN 2, SN 4, SN 8 or SN 16 following ISO 13966, as applicable, or as the actual value
2
obtained in the test, expressed in kN/m .
4.2.3 Ring stiffness of fittings
Due to its geometry, the ring stiffness of a fitting is deemed to be at least equal to the ring stiffness of a
corresponding pipe made from the same material and having the same wall thickness and design.
For other constructions, the ring stiffness of bends and branches with the largest side branch shall be
measured in accordance with 5.2.2. All fittings of the same design family can be classified with the same ring
stiffness class.
The ring stiffness of a thermoplastics fitting shall be expressed either as SN 2, SN 4, SN 8 or SN 16 following
2
ISO 13966, as applicable, or as the actual value obtained in the test, expressed in kN/m .
The fitting manufacturer shall declare for which pipe ring stiffness classes the product is suitable.
4.3 Dimensional tolerances
The manufacturer shall declare the relevant dimensional tolerances for the connection of pipes and fittings by
means of:
a) reference to a specific European standard as given Annex A, as applicable
6

---------------------- Page: 8 ----------------------
oSIST prEN 15012:2011
prEN 15012:2011 (E)
b) in the absence of a), reference to a specific European product specification
c) in the absence of a) and b) reference to an International Standard,
d) in the absence of a), b), and c), by stating the values of his own specification and associated connecting
method.
Dimensions shall be measured in accordance with 5.3 and shall be within the declared tolerances.
7

---------------------- Page: 9 ----------------------
oSIST prEN 15012:2011
prEN 15012:2011 (E)
4.4 Tightness
For products in accordance with this standard, tightness is required. Pipes and fittings covered by this
standard and having passed the type testing in accordance with the evaluation of conformity clause are
deemed to be tight.
Connections between pipes and/or fittings shall be tested in accordance with 5.4. No water leakage and no air
leakage shall occur during the test period.
4.5 Durability
4.5.1 Durability of tightness related to material
The durability of tightness related to material from which the pipes and fittings are manufactured, shall be
assessed by testing in accordance with 5.5.1.
4.5.2 Durability of tightness after elevated temperature cycling test of pipes and fittings
The tightness after elevated temperature cycling shall be tested in accordance with 5.5.2. The connections
between pipes and/or fittings shall not show any leakage before and after the test. The sagging shall not
exceed the following values:
 DN ≤ 50:  ≤ 3 mm;
 DN > 50:  0,05 × d mm.
n
4.5.3 Durability of tightness of elastomeric sealing connections between pipes and/or fittings
The tightness of elastomeric sealing connections is deemed to be durable if the sealing element conforms to
EN 681-1, EN 681-2, EN 681-3 or EN 681-4, as applicable.
4.6 Release of dangerous substances
Products covered by this standard should not contain or release any of the substances considered dangerous
according to existing national provisions.
5 Test methods
5.1 Reaction to fire of pipes and fittings
The reaction to fire is tested according to the applicable test methods.
When tested in accordance with EN 13823 (SBI test), the mounting and fixing conditions of the samples to be
tested shall be in accordance with EN 16000.
5.2 Maximum load for admissible deformation
5.2.1 Ring stiffness of thermoplastics pipes
For thermoplastics pipes the ring stiffness shall be determined in accordance with EN ISO 9969.
8

---------------------- Page: 10 ----------------------
oSIST prEN 15012:2011
prEN 15012:2011 (E)
5.2.2 Ring stiffness of thermoplastics fittings
For thermoplastics structured-wall fabricated fittings, the ring stiffness of bends and branches shall be
measured in accordance with EN ISO 13967.
5.3 Dimensional tolerances
The dimensions shall be measured in accordance with EN ISO 3126.
5.4 Tightness
Sealing ring connections between pipes and/or fittings shall be tested in accordance with EN 1053 and
EN 1054, whereby the sampling procedure is free and the number of test pieces is one (see clause 6.2).
Fused, cemented and adhesive bonded connections are deemed to be tight when assembled in accordance
with the manufacturer's instructions. Such instructions shall be made available by the manufacturer.
5.5 Durability
5.5.1 Durability of tightness related to material
Depending on the material from which the products are made, testing shall be done in accordance with
following provisions=
a) PVC based compound/formulation:
- Vicat softening temperature shall be determined in accordance with EN727, using the conditions
as given in EN 1329-1.

b) PE based compound/formulation:
- Melt Flow Index shall be determined in accordance with ISO1133 (190°C) using the conditions as
given in EN 1519-1 in relevant clause.
- Oxidation Induction Time shall be determined in accordance with EN728 (200°C) using the
conditions as given in EN 1519-1 in relevant clause

c) PP based compound/formulation:
- Melt Flow Index shall be determined in accordance with ISO1133 (230°C) using the conditions as
given in EN 1451-1 in relevant clause.
- Oxidation Induction Time shall be determined in accordance with EN728 using the conditions as
given in EN 1451-1 in relevant clause.

d) ABS based compound/formulation:
- Vicat softening temperature shall be determined in accordance with EN727, using the conditions as
given in EN 1455-1 in relevant clause.

e) PVC/SAN based compound/formulation:
- Vicat softening temperature shall be determined in accordance with EN727, using the conditions as
given in EN 1565-1 in relevant clause.

f) PVC-C based compound/formulation:
- Vicat softening temperature shall be determined in accordance with EN727, using the conditions as
given in EN 1566-1 in relevant clause.


5.5.2 Durability of tightness after elevated temperature cycling test of pipes and fittings
This characteristic shall be tested in accordance with EN 1055.

9

---------------------- Page: 11 ----------------------
oSIST prEN 15012:2011
prEN 15012:2011 (E)
6 Evaluation of conformity
6.1 General
The compliance of pipes and fittings to the requirements of this standard and with the declared values
(including classes) shall be demonstrated by:
 initial type testing;
 factory production control by the manufacturer, including product assessment.
The manufacturer shall always retain the overall control and shall have the necessary means to take
responsibility for the product.
6.2 Initial type testing – Type testing
6.2.1 General
Initial Type Testing and Type Testing shall be performed to demonstrate compliance with this European
standard.
All essential characteristics for which the manufacturer declares performances, are subject to Initial Type
Testing. In addition, the need to perform Type Tests applies to all other characteristics included in a standard
when the manufacturer claims compliance with, unless the standard gives provisions (e.g. use of previously
existing data, CWFT and conventionally accepted performance) for declaring performances without
performing tests.
For the purposes of testing, the manufacturer's products may be grouped into families, where it is considered
that the results for one or more characteristics from any product within the family are representative for that
same characteristic for all products within that same family.
NOTE Products may be in different families for different characteristics.
For type testing the following family groups apply:
a) Size groups for pipes and fittings as given in Table 1.
Table 1 — Size groups
Size group
Range of nominal diameters, d
n
1
32 < d ≤ 63
n
2 63 < d ≤ 180
n
3
d > 180
n

b) Product groups for thermoplastics piping components as given in Table 2.
Table 2 — Product groups
Type group Thermoplastics piping components
1 Pipes
2 Bends
10

---------------------- Page: 12 ----------------------
oSIST prEN 15012:2011
prEN 15012:2011 (E)
3 Branches
4 Other fittings

In addition, Type Tests or Initial Type Testing shall be performed for all characteristics included in the
standard for which the manufacturer declares performances:
 at the beginning of the production of a new pipe or fitting design, raw material or supplier of the
components;
 at the beginning of a new method of production (whenever this may affect the stated properties); or
they shall be repeated for the appropriate characteristic(s), whenever a change occurs in the pipe and fitting
design, in the raw material or in the supplier of the components, or in the production process (subject to the
definition of a family), which would affect significantly this (those) characteristic(s).
This is not applicable for routine in-process adjustment and extension of the product range (see Table 3).
A change of supplier of a material or stabiliser does not lead to a change in performance if the chemical
composition remains the same.
Material modifications within certain limits are not considered as a change of material. Guidance for these
limits can be found in the standards given in Annex B.
Tests previously performed in accordance with the provisions of this standard, respectively standards as listed
in Annex A, may be taken into account provided that they were made to the same or a more rigorous test
method, under the same system of attestation of conformity on the same product or products of similar design,
construction and functionality, such that the results are applicable to the product in question.
Products marked in accordance with appropriate harmonised European specifications may be presumed to
have the performances stated with that marking, although this does not replace the responsibility on the
plastic pipe and fitting designer to ensure that the plastic piping system as a whole is correctly designed and
its components have the necessary performance values to meet the design.
6.2.2 Test samples, testing and compliance criteria
The initial type testing of the characteristics according to Clause 4 shall be performed in accordance with the
sampling procedure given under type tests (TT) of the applicable product specific standards for assessment of
conformity as given in Annex B. If the standard does not contain one or more of the characteristics, then
testing as given in Table 3 shall apply.
For products where no such standard exists Table 3 shall apply.
11

---------------------- Page: 13 ----------------------
oSIST prEN 15012:2011
prEN 15012:2011 (E)
Table 3 — Type testing of pipes and fittings
a
Requirement Sampling procedure Compliance
Testing relevant to
clause of this (minimum sampling) criteria
Essential Characteristics
I M E
European
Standard
b b
Reaction to fire — See classification
+ + Once/compound or
4.1
c in EN 13501-1
formulation
Maximum load for  Pass/fail
One pipe sample/size
admissible deformation – + + +
4.2.2 group/SN class for each
d
Ring stiffness of pipes
material

Maximum load for Pass/fail
Once/size/product
admissible deformation – + + +
group 2 (largest angle
4.2.3
d
Ring stiffness of fittings
of bend of the size) and
3 (45° branch)
Dimensional tolerances + + + Pass/fail
Once/size/product/
4.3 compound or
formulation
e
Tightness + — Pass/fail
+ One diameter/size
4.4
group/joint design
Durability of tightness + + + Pass/fail
Once/compound or
4.5.1
related to material
formulation
Durability of tightness after + + + Pass/fail
Once/compound or
elevated temperature cycling 4.5.2
formulation
test of pipes and fittings
Durability of tightness of + + + Pass/fail
Once/compound or
elastomeric sealing
formulation
4.5.3
connections between pipes
and/or fittings
a
I is initial type test in case of new system
M is change of material
E is extension of the product range with new size group or fitting group.
+ denotes testing relevant for the characteristic-occurrence-combination.
b Only obligatory if subject to regulatory requirements applicable in the place of use (see also Table ZA.2).
c In case of single burning item (SBI) test the preferred vertical dimension is 110 mm and the preferred horizontal dimension
is 40 mm, which will then be representative for all di
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.