SIST EN 61970-456:2013/A1:2016
(Amendment)Energy management system application program interface (EMS-API) - Part 456: Solved power system state profiles
Energy management system application program interface (EMS-API) - Part 456: Solved power system state profiles
Schnittstelle für Anwendungsprogramme für Netzführungssysteme (EMS-API) - Teil 456: Gelöste Zustandsprofile des Stromversorgungssystems
Interface de programmation d'application pour système de gestion d'énergie (EMS-API) - Partie 456: Profils d'état de réseaux électriques résolus
Programski vmesnik za sistem za upravljanje energije (EMS-API) - 456. del: Profili stanja sproščenega elektroenergetskega sistema - Dopolnilo A1
General Information
Relations
Standards Content (Sample)
SLOVENSKI STANDARD
SIST EN 61970-456:2013/A1:2016
01-marec-2016
3URJUDPVNLYPHVQLN]DVLVWHP]DXSUDYOMDQMHHQHUJLMH(06$3,GHO3URILOL
VWDQMDVSURãþHQHJDHOHNWURHQHUJHWVNHJDVLVWHPD'RSROQLOR$
Energy management system application program interface (EMS-API) - Part 456: Solved
power system state profiles
Ta slovenski standard je istoveten z: EN 61970-456:2013/A1:2016
ICS:
29.240.30 Krmilna oprema za Control equipment for electric
elektroenergetske sisteme power systems
35.200 Vmesniška in povezovalna Interface and interconnection
oprema equipment
SIST EN 61970-456:2013/A1:2016 en
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
---------------------- Page: 1 ----------------------
SIST EN 61970-456:2013/A1:2016
---------------------- Page: 2 ----------------------
SIST EN 61970-456:2013/A1:2016
EUROPEAN STANDARD EN 61970-456:2013/A1
NORME EUROPÉENNE
EUROPÄISCHE NORM
January 2016
ICS 33.200
English Version
Energy management system application program interface
(EMS-API) - Part 456: Solved power system state profiles
(IEC 61970-456:2013/A1:2015)
Interface de programmation d'application pour système de Schnittstelle für Anwendungsprogramme für
gestion d'énergie (EMS-API) - Partie 456: Profils d'état de Netzführungssysteme (EMS-API) - Teil 456: Globale
réseaux électriques résolus Stabilitätsbeurteilung in elektrischen Versorgungssystemen
(IEC 61970-456:2013/A1:2015) (IEC 61970-456:2013/A1:2015)
This amendment A1 modifies the European Standard EN 61970-456:2013; it was approved by CENELEC on 2015-11-03. CENELEC
members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this amendment the
status of a national standard without any alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC
Management Centre or to any CENELEC member.
This amendment exists in three official versions (English, French, German). A version in any other language made by translation under the
responsibility of a CENELEC member into its own language and notified to the CEN-CENELEC Management Centre has the same status as
the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic,
Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia,
Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland,
Turkey and the United Kingdom.
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels
© 2016 CENELEC All rights of exploitation in any form and by any means reserved worldwide for CENELEC Members.
Ref. No. EN 61970-456:2013/A1:2016 E
---------------------- Page: 3 ----------------------
SIST EN 61970-456:2013/A1:2016
EN 61970-456:2013/A1:2016
European foreword
The text of document 57/1591/FDIS, future edition 1 of IEC 61970-456:2013/A1, prepared by
IEC/TC 57 "Power systems management and associated information exchange" was submitted to the
IEC-CENELEC parallel vote and approved by CENELEC as EN 61970-456:2013/A1:2016.
The following dates are fixed:
– latest date by which the document has to be implemented at (dop) 2016-08-03
national level by publication of an identical national
standard or by endorsement
– latest date by which the national standards conflicting with (dow) 2018-11-03
the document have to be withdrawn
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. CENELEC [and/or CEN] shall not be held responsible for identifying any or all such
patent rights.
Endorsement notice
The text of the International Standard IEC 61970-456:2013/A1:2015 was approved by CENELEC as a
European Standard without any modification.
2
---------------------- Page: 4 ----------------------
SIST EN 61970-456:2013/A1:2016
IEC 61970-456
®
Edition 1.0 2015-09
INTERNATIONAL
STANDARD
AMENDMENT 1
Energy management system application program interface (EMS-API) –
Part 456: Solved power system state profiles
INTERNATIONAL
ELECTROTECHNICAL
COMMISSION
ICS 33.200 ISBN 978-2-8322-2911-8
Warning! Make sure that you obtained this publication from an authorized distributor.
® Registered trademark of the International Electrotechnical Commission
---------------------- Page: 5 ----------------------
SIST EN 61970-456:2013/A1:2016
– 2 – IEC 61970-456:2013/AMD1:2015
© IEC 2015
FOREWORD
This amendment has been prepared by IEC technical committee 57: Power systems
management and associated information exchange.
IEC 61970-456:2013 is based on IEC 61970-301 Edition 4 (2013). Both are based on the
61970 UML version CIM14. The amendment is based on IEC 61970-301 Edition 5 (2013) and
the 61970 UML version CIM15.
For the Topology profile this amendment includes the following changes with respect to the
previous edition:
a) The classes Name and NameType classes have been added.
b) The class TopologicalNode has been extended with the role ConnectivityNodeContainer.
c) The attribute IdentifiedObject.description has been removed.
For the StateVariables profile this edition includes the following changes with respect to the
previous edition:
a) The role TopologicalIsland.ToplogicalNodes has been replaced by
ToplogicalNode.TopologicalIsland.
b) The documentation of attributes SvPowerFlow.p and SvPowerFlow.q has been updated.
c) The attribute SvShuntCompensatorSections.sections has been changed from Integer to
Float.
d) The attribute SvShuntCompensatorSections.continuousSections is removed.
e) The attribute SvTapStep.position is changed from Integer to Float.
f) The attribute SvTapStep.continuousPosition is removed.
g) The attribute SvVoltage.angle is changed from radians to degrees.
h) The data types have be
...
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.