Water meters - Part 3: Test methods and equipment

This document applies to water meters intended for residential, commercial, light industrial and industrial use, and specifies the test parameters and the test methods for water meters, irrespective of the design technologies, as specified in EN 14154-1:2005+A1, used to meter the actual volume of clean cold potable water or heated water, flowing through a fully charged, closed conduit. These water meters shall incorporate devices, which indicate the integrated volume.
In the case where water meters having a value of Q3 > 160 m3/h, the test schedule may make provisions for modification of the Reference Conditions, to meet individual test laboratory limitations, when testing specifically for endurance or for performance under Influence Quantities.
Meters thus tested shall be marked so as to unambiguously indicate part compliance with this document. To augment this marking the meter manufacturer shall, in addition, be obliged to fully disclose the specific non compliance(s)due to the test laboratory limitations.

Wasserzähler - Teil 3: Prüfverfahren und -einrichtungen

Dieses Dokument gilt für Wasserzähler, die für den Einsatz in privaten und gewerblichen Bereichen und in Bereichen der Leichtindustrie und Industrie bestimmt sind. Es legt, ungeachtet der Technologie, die Prüfparameter und Prüfverfahren für die in !EN 14154-1:2005+A1" festgelegten Wasserzähler fest, die zur Messung des tatsächlichen Volumens von sauberem, kaltem Trinkwasser oder erwärmtem Wasser, das durch eine voll gefüllte, geschlossene Leitung fließt, eingesetzt werden. Diese Zähler müssen mit Einrichtungen versehen sein, die das summierte Volumen anzeigen.
Bei Wasserzählern mit einem Wert von Q3 > 160 m3/h dürfen zur Berücksichtigung von begrenzten Möglich-keiten in vorhandenen Prüflaboratorien im Prüfplan Veränderungen der Referenzbedingungen vorgesehen werden, insbesondere bei der Beständigkeitsprüfung und der Leistungsprüfung unter Einflussgrößen.
Bei der Kennzeichnung der auf diese Weise geprüften Zähler muss eindeutig darauf hingewiesen werden, dass sie dem vorliegenden Dokument nur teilweise entsprechen. Darüber hinaus ist der Zählerhersteller verpflichtet, diese Kennzeichnung mit einer umfassenden Beschreibung zu ergänzen, in der genau beschrieben wird, welche begrenzten Möglichkeiten im Prüflabor zu dieser Abweichung geführt haben.

Compteurs d'eau - Partie 3: Méthodes et équipement d'essai

Le présent document s’applique aux compteurs d’eau destinés à une utilisation résidentielle, commerciale, industrielle légère et industrielle, et spécifie les paramètres et les méthodes d’essai pour les compteurs d’eau, indépendamment des technologies de conception, comme spécifié dans !l’EN 14154-1:2005+A1:2007", utilisés pour mesurer le volume réel d’eau potable froide ou d’eau chaude s'écoulant dans une conduite fermée et à pleine charge. Ces compteurs d’eau doivent comprendre des dispositifs indiquant le volume intégré.
Dans le cas de compteurs d’eau ayant une valeur de Q3 > 160 m3/h, le programme d'essai peut prévoir une modification des conditions de référence pour satisfaire aux limitations du laboratoire d’essais individuel, en cas d’essais spécifiques liés à l’endurance ou à la performance sous des grandeurs d’influence.
Les compteurs ainsi soumis à l’essai doivent être marqués de manière à indiquer sans ambiguïté la conformité partielle au présent document. Pour compléter ce marquage, le fabricant du compteur est, en outre, obligé de déclarer explicitement la ou les non-conformité(s) spécifique(s) due(s) aux limitations du laboratoire d’essais.

Vodomeri - 3. del: Preskusne metode in oprema

General Information

Status
Withdrawn
Publication Date
21-May-2007
Withdrawal Date
05-Feb-2013
Technical Committee
Current Stage
9900 - Withdrawal (Adopted Project)
Start Date
05-Feb-2013
Due Date
28-Feb-2013
Completion Date
06-Feb-2013

Relations

Buy Standard

Standard
EN 14154-3:2005+A1:2007
English language
84 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Water meters - Part 3: Test methods and equipmentVodomeri - 3. del: Preskusne metode in opremaCompteurs d'eau - Partie 3: Méthodes et équipement d'essaiWasserzähler - Teil 3: Prüfverfahren und -einrichtungenTa slovenski standard je istoveten z:EN 14154-3:2005+A1:2007SIST EN 14154-3:2005+A1:2007en;de91.140.60Sistemi za oskrbo z vodoWater supply systemsICS:SIST EN 14154-3:20051DGRPHãþDSLOVENSKI
STANDARDSIST EN 14154-3:2005+A1:200701-junij-2007







EUROPEAN STANDARD NORME EUROPÉENNE EUROPÄISCHE NORM
EN 14154-3:2005+A1
April 2007 ICS 91.140.60 Supersedes EN 14154-3:2005English Version
Water meters - Part 3: Test methods and equipment
Compteurs d'eau - Partie 3: Méthodes et équipement d'essai
Wasserzähler - Teil 3: Prüfverfahren und -einrichtungen This European Standard was approved by CEN on 26 July 2004 and includes Amendment 1 approved by CEN on 6 March 2007.
CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN Management Centre or to any CEN member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the CEN Management Centre has the same status as the official versions.
CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION EUROPÄISCHES KOMITEE FÜR NORMUNG
Management Centre: rue de Stassart, 36
B-1050 Brussels © 2007 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 14154-3:2005+A1:2007: E



EN 14154-3:2005+A1:2007 (E) 2 Contents Page Foreword.5 1 Scope.6 2 Normative references.6 3 Reference conditions.7 4 Administrative and external examination for approval programme.7 5 Performance tests for approval programme.8 5.1 General requirements for the test installation.8 5.1.1 Location.8 5.1.2 Test water.9 5.1.3 Calibrated reference device.9 5.1.4 Freedom from spurious influences.9 5.1.5 Group testing of meters.10 5.2 Static pressure test.10 5.2.1 Object of test.10 5.2.2 Preparation.10 5.2.3 Test procedure.10 5.2.4 Acceptance criteria.11 5.3 Determination of intrinsic errors (of indication).11 5.3.1 Object of test.11 5.3.2 Preparation.11 5.3.3 Test procedure.12 5.3.4 Acceptance criteria.12 5.4 Error (of indication) tests.13 5.4.1 Object of test.13 5.4.2 Preparation.13 5.4.3 Test Procedure.13 5.4.4 Acceptance criteria.13 5.5 Absence of flow test.13 5.5.1 Object of test.13 5.5.2 Preparation.13 5.5.3 Test procedure.13 5.5.4 Acceptance criteria.13 5.6 Water temperature test (within ROC).14 5.6.1 Object of test.14 5.6.2 Preparation.14 5.6.3 Test procedure.14 5.6.4 Acceptance criteria.14 5.7 Overload water temperature test.14 5.7.1 Object of test.14 5.7.2 Preparation.14 5.7.3 Test procedure.15 5.7.4 Acceptance criteria.15 5.8 Water pressure test.15 5.8.1 Object of test.15 5.8.2 Preparation.15 5.8.3 Test procedure.15 5.8.4 Acceptance criteria.15 5.9 Verification of flow profile sensitivity classes.15 5.9.1 Object of test.15 5.9.2 Preparation.16 5.9.3 Test procedure.16 5.9.4 Acceptance criteria.16



EN 14154-3:2005+A1:2007 (E) 3 5.10 Tests on ancillary devices of a water meter.18 5.10.1 Object of test.18 5.10.2 Preparation.18 5.10.3 Procedure.18 5.10.4 Acceptance criteria.18 5.11 Pressure loss test.18 5.11.1 Object of test.18 5.11.2 Preparation.18 5.11.3 Test procedure.19 5.11.4 Acceptance criteria.19 5.12 Reverse flow test.19 5.12.1 Meters designed to measure reverse flows.19 5.12.2 Meters not designed to measure reverse flows.19 5.13 Endurance tests.20 5.13.1 Continuous flow test.20 5.13.2 Discontinuous flow test.23 6 Performance tests related to influence quantities.26 6.1 General requirements.26 6.1.1 Environmental classification.26 6.1.2 Electromagnetic environments.26 6.1.3 Reference conditions.26 6.1.4 Test volumes for measuring error (of indication) of a water meter.27 6.1.5 Influence of the water temperature.27 6.1.6 Requirements for environmental tests.27 6.1.7 Equipment under test (EUT).27 6.2 Climatic and mechanical environment.29 6.2.1 Dry heat (non-condensing).29 6.2.2 Cold.30 6.2.3 Damp heat, cyclic (condensing).31 6.2.4 Vibration (random).33 6.2.5 Mechanical shock.34 6.3 Electromagnetic environment.35 6.3.1 Electrostatic discharge.35 6.3.2 Radiated radio frequency/Electromagnetic fields.36 6.4 Power supply.38 6.4.1 A.C. power voltage variation.38 6.4.2 A.C. voltage dips and short interruptions.39 6.4.3 Surge immunity.41 6.4.4 Electrical fast transients/Burst.42 6.4.5 D.C. power voltage variation.43 6.5 Static magnetic field.45 6.5.1 Object of test.45 6.5.2 Preparation.45 6.5.3 Test procedure.45 6.5.4 Acceptance criteria.45 6.6 Interruption in battery supply.46 6.6.1 Object of test.46 6.6.2 Test procedure.46 6.6.3 Acceptance criteria.46 Annex A (normative)
Irregularity in water velocity field.47 A.1 Irregularity in water velocity field.47 A.2 Flow disturbers.47 Annex B (informative)
Examples of methods and components used for testing Concentric Water Meters.58 Annex C (normative)
Equipment and method used to determine meter error.61 C.1 Principle.61 C.2 Description of the test rig.61 C.3 Pipe-work.61 C.3.1 Description.61



EN 14154-3:2005+A1:2007 (E) 4 C.3.2 Test section.62 C.3.3 Precautions to be taken during tests.62 C.3.4 Special arrangements for the installation of meters.62 C.3.5 Cyclic distortion of the meter.64 C.3.6 Major factors affecting the measurement of errors of indication.64 Annex D (informative)
Equipment and methods for pressure loss test.66 D.1 Principle.66 D.2 Pressure loss test equipment.66 D.2.1 General.66 D.2.2 Measuring section.66 D.3 Test procedure.71 D.3.1 Determination of pressure loss attributable to pipe lengths for water meters (measurement 1)71 D.3.2 Measurement and calculation of the actual ∆∆∆∆P of a water meter (measurement 2).72 Annex E (informative)
Characteristics of reference devices.73 E.1 General.73 E.2 Types of reference devices.73 E.2.1 Calibration using volumetric vessels.73 E.2.2 Calibration using reference meters (master meters).74 E.2.3 Calibration using calibrated tubes.75 E.2.4 Calibration by weighing method.76 E.2.5 Other calibration methods.76 Annex ZA (informative)
!!!!Relationship between this European Standard and the Essential Requirements of EU Directive 22/2004/EC on Measuring Instruments.77 Bibliography.84



EN 14154-3:2005+A1:2007 (E) 5 Foreword This document (EN 14154-3:2005:2007) has been prepared by Technical Committee CEN/TC 92 “Water meters”, the secretariat of which is held by SNV. This document shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by October 2007 and conflicting national standards shall be withdrawn at the latest by October 2007. This document includes Amendment 1, approved by CEN on 2007-03-06. This document supersedes EN 14154-3:2005. The start and finish of text introduced or altered by amendment is indicated in the text by tags ! ". This European Standard has been prepared under a mandate given to CEN by the European Commission and the European Free Trade Association, and supports essential requirements of EU Directive(s). For relationship with EU Directive(s), see informative Annex ZA, which is an integral part of this document. The standard consists of 3 parts. The other parts are:  Part 1: General Requirements  Part 2: Installation and conditions of use In developing a new Standard, CEN/TC 92 aimed to harmonise it with existing standards and recommendations for water meters, to accommodate new technologies and anticipating the requirements of the Directive 22/2004 EC on Measuring Instruments. According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom.



EN 14154-3:2005+A1:2007 (E) 6 1 Scope This document applies to water meters intended for residential, commercial, light industrial and industrial use, and specifies the test parameters and the test methods for water meters, irrespective of the design technologies, as specified in !EN 14154-1:2005+A1", used to meter the actual volume of clean cold potable water or heated water, flowing through a fully charged, closed conduit. These water meters shall incorporate devices, which indicate the integrated volume. In the case where water meters having a value of Q3 > 160 m3/h, the test schedule may make provisions for modification of the Reference Conditions, to meet individual test laboratory limitations, when testing specifically for endurance or for performance under Influence Quantities. Meters thus tested shall be marked so as to unambiguously indicate part compliance with this document. To augment this marking the meter manufacturer shall, in addition, be obliged to fully disclose the specific non compliance(s) due to the test laboratory limitations. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. !EN 14154-1:2005+A1:2007", Water meters — Part 1: General requirements !EN 14154-2:2005+A1", Water meters — Part 2: Installation and conditions of use EN 60068-1:1994, Environmental testing — Part 1: General and guidance EN 60068-2-1:1993, Environmental testing — Part 2: Tests, Test A: Cold EN 60068-2-2:1993, Environmental testing — Part 2: Tests, Test B: Dry heat EN 60068-2-30:1999, Environmental testing — Part 2: Tests — Test Db and guidance: Damp heat, cyclic ((12 + 12) h cycle) EN 60068-2-31:1993, Environmental testing — Part 2: Tests — Test Ec: Drop and topple, primarily for equipment-type specimens EN 60068-2-47:1999 Environmental testing — Part 2-47: Test methods — Mounting of components, equipment and other articles for vibration, impact and similar dynamic tests EN 60068-2-64:1994, Environmental testing — Part 2: Test methods — Test Fh: Vibration, broad-band random (digital control) and guidance EN 60068-3-1:1999, Environmental testing — Part 3: Background information, Section 1: Cold and dry heat tests EN 61000-4-2:1995, Electromagnetic compatibility (EMC) — Part 4-2: Testing and measurement techniques — Electrostatic discharge immunity test EN 61000-4-3:1996, Electromagnetic compatibility (EMC) — Part 4-3: Testing and measurement techniques — Radiated, radio-frequency, electromagnetic field immunity test EN 61000-4-4:1995, Electromagnetic compatibility (EMC) — Part 4-4: Testing and measurement techniques — Electrical fast transient/burst immunity test EN 61000-4-5:1995, Electromagnetic compatibility (EMC) — Part 4-5: Testing and measurement techniques — Surge immunity test



EN 14154-3:2005+A1:2007 (E) 7 EN 61000-4-11:1994, Electromagnetic compatibility (EMC) — Part 4-11: Testing and measurement techniques — Voltage dips, short interruptions and voltage variations immunity tests IEC 60068-3-4:2001, Environmental testing — Part 3-4: Supporting documentation and guidance — Damp heat tests ISO 4185, Measurement of fluid flow in closed conduits — Weighing method OIML D4, Installation and Storage Conditions for Cold Water Meters OIML D7, The Evaluation of Flow Standards and Facilities Used for Testing Water Meters OIML P7, Planning of Metrology and Testing Laboratories 3 Reference conditions All applicable influence quantities, except for the influence quantity being tested, shall be held at the following values during pattern approval tests on a water meter: Flowrate: 0,7 × (Q2 + Q3) ± 0,03 × (Q2 + Q3) Working (water) temperature: For meters T30 and T50: (20 ± 5) °C;
For meters T ≥ 70: (50 ± 5) °C Working (water) pressure: 200 kPa (2,0 bar) Ambient temperature range: 15 °C to 25 °C* Ambient relative humidity range: 45 % to 75 %* Ambient atmospheric pressure range: 86 kPa to 106 kPa (0,86 bar to 1,06 bar) Power supply voltage (mains a.c.): Nominal voltage (Unom) ± 5 % Power supply frequency: Nominal frequency (fnom) ± 2 % Power supply voltage (battery): A voltage U in the range; Umin ≤ U ≤ Umax During each test, the temperature and relative humidity shall not vary by more than 5 °C or 10 % respectively within the reference range. * Here the ambient temperature and/or ambient relative humidity exceed the above-mentioned ranges, the effect on the error (of indication) shall be taken in account. 4 Administrative and external examination for approval programme The meter and its technical documentation shall be examined before entering the rest of the test program. The administrative examination shall demonstrate that the water meter fulfils the respective requirements of Clause 4 of !EN 14154-1:2005+A1:2007", which can be verified by administrative work and shall show that the meter is manufactured in conformity with it.



EN 14154-3:2005+A1:2007 (E) 8 The following documents shall be examined, as far as is relevant, for the respective water meter:  general description of the water meter and its working principle;  conceptual design, general assembly drawings;  subassemblies drawings, circuits, etc.;  metrological characteristics claimed;  indicated device and dial drawings;  security sealing plan drawings;  list of mechanical components and materials;  list of electronic components and specifications;  description of the software;  descriptions and explanations, necessary to understanding the above, including the operation of the instrument;  results of design calculations examinations etc.;  test reports. The following aspects of the meter design shall be examined on at least one meter
...

Questions, Comments and Discussion