Household electric thermal storage room heaters - Methods for measuring performance

Applies to electric storage heaters intended to heat the room in which they are located. It defines the main performance characteristics and describes methods for measuring these characteristics. It does not apply to heating appliances incorporated in the building structure, to central heating systems or to floor heating appliances.

Elektrische Wärmespeicher - Raumheizgeräte für den Hausgebrauch - Verfahren zur Messung der Gebrauchseigenschaften

Appareils électrodomestiques de chauffage à accumulation des locaux - Méthodes de mesure de l'aptitude à la fonction

Gospodinjski termoakumulacijski grelniki - Metode za merjenje učinkovitost delovanja - Dopolnilo AB

General Information

Status
Not Published
Public Enquiry End Date
11-Sep-2025
Current Stage
4020 - Public enquire (PE) (Adopted Project)
Start Date
30-Jun-2025
Due Date
17-Nov-2025

Relations

Buy Standard

Draft
EN 60531:2002/oprAB:2025
English language
14 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)


SLOVENSKI STANDARD
01-september-2025
Gospodinjski termoakumulacijski grelniki - Metode za merjenje učinkovitost
delovanja - Dopolnilo AB
Household electric thermal storage room heaters - Methods for measuring performance
Elektrische Wärmespeicher - Raumheizgeräte für den Hausgebrauch - Verfahren zur
Messung der Gebrauchseigenschaften
Appareils électrodomestiques de chauffage à accumulation des locaux - Méthodes de
mesure de l'aptitude à la fonction
Ta slovenski standard je istoveten z: EN 60531:2000/prAB:2025
ICS:
97.100.10 Električni grelniki Electric heaters
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

EUROPEAN STANDARD DRAFT
EN 60531:2000
NORME EUROPÉENNE
EUROPÄISCHE NORM
prAB
June 2025
ICS 97.100 -
English Version
Household electric thermal storage room heaters - Methods for
measuring performance
Appareils électrodomestiques de chauffage à accumulation Elektrische Wärmespeicher - Raumheizgeräte für den
des locaux - Méthodes de mesure de l'aptitude à la fonction Hausgebrauch - Verfahren zur Messung der
Gebrauchseigenschaften
This draft amendment prAB, if approved, will modify the European Standard EN 60531:2000; it is submitted to CENELEC members for
enquiry.
Deadline for CENELEC: 2025-09-12.

It has been drawn up by CLC/TC 59X.

If this draft becomes an amendment, CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which
stipulate the conditions for giving this amendment the status of a national standard without any alteration.

This draft amendment was established by CENELEC in three official versions (English, French, German).
A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to
the CEN-CENELEC Management Centre has the same status as the official versions.

CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic,
Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the
Netherlands, Norway, Poland, Portugal, Republic of North Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland,
Türkiye and the United Kingdom.

Recipients of this draft are invited to submit, with their comments, notification of any relevant patent rights of which they are aware and to
provide supporting documentation.

Warning : This document is not a European Standard. It is distributed for review and comments. It is subject to change without notice and
shall not be referred to as a European Standard.

European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
CEN-CENELEC Management Centre: Rue de la Science 23, B-1040 Brussels
© 2025 CENELEC All rights of exploitation in any form and by any means reserved worldwide for CENELEC Members.
Project: 78782 Ref. No. EN 60531:2000/prAB:2025 E

Contents Page
European foreword . 3
1 Modification to Clause 1, “Scope” . 4
2 Modification to Clause 2, “Normative References” . 4
3 Modification to Clause 3, “Terms and definitions” . 4
4 Modification to Clause 5, “List of measurements” . 8
5 Modifications to Clause 6, “General conditions for measurements” . 8
6 Modification to Clause 9, “Room heating capability” . 9
7 Modification to Clause 10, “Heat retention” . 9
8 Modification of Clause 13, “Stability of room temperature” .10
9 Modification to Clause 15, “Control types and functionality” .12
10 Modification to Annex B, “Climatic test room” .13
11 Modification to Annex D .14
12 Modifications to the Bibliography .14
13 Deletion of Annex ZZ, “Relationship between this European Standard and the Ecodesign
requirements of Commission Regulation EU No 2015/1188 aimed to be covered” .14
European foreword
This document (EN 60531:2000/prAB:2025) has been prepared by CLC/TC 59X “Performance of household
and similar electrical appliances”.
This document is currently submitted to the Enquiry.
The following dates are proposed:
• latest date by which the existence of this (doa) dav + 6 months
document has to be announced at national level
• latest date by which this document has to be (dop) dav + 12 months
implemented at national level by publication of
an identical national standard or by
endorsement
• latest date by which the national standards (dow) dav + 36 months
conflicting with this document have to be (to be confirmed or
withdrawn modified when voting)

1 Modification to Clause 1, “Scope”
Replace the content of Clause 1 with the following:
“This document applies to electric storage heaters having a daily operating cycle and intended to heat the room
in which they are located.
NOTE 1 This document does not apply to heating appliances incorporated in the building structure, to central heating
systems or to floor heating installations.
NOTE 2 If an appliance is intended to be operated as a storage heater or as a direct-acting room heater, it is also tested
in accordance with EN 60675.
NOTE 3 If an appliance has a heat retention of less than 20 %, it is not considered to be a storage heater.
This document defines the main performance characteristics of storage heaters and specifies methods for
measuring these characteristics, for the information of users.
NOTE 4 Information which can be of interest to the consumer is listed in Annex D.
This document does not specify values for performance characteristics.
NOTE 5 This document does not deal with:
—  safety requirements (EN 60335-2-61);
—  acoustical noise of electric thermal storage room heaters (EN 60704-2-5).”
2 Modification to Clause 2, “Normative References”
Add the following references:
EN 50564:2011, Electrical and electronic household and office equipment - Measurement of low power
consumption
3 Modification to Clause 3, “Terms and definitions”
Replace the content of Clause 3 with the following:
“For the purposes of this document, the following terms and definitions apply.
ISO and IEC maintain terminology databases for use in standardization at the following addresses:
— IEC Electropedia: available at https://www.electropedia.org/
— ISO Online browsing platform: available at https://www.iso.org/obp
3.1
local space heater
device equipped with one or more heat generators to convert electricity from the mains or gaseous or liquid
fuels directly into heat output to provide thermal comfort for human beings in the enclosed space in which it is
situated by direct heat transfer, possibly combined with heat output to other spaces or with heat transfer to a
fluid
3.2
storage local space heater
electric local space heater designed to store heat in an accumulating isolated core and to discharge it for several
hours after the accumulation phase
3.3
minimum discharge condition
condition under which the appliance is operated, the means for controlling the heat output, such as flaps and
fans, being set at the lowest position
3.4
maximum discharge condition
condition under which the appliance is operated, the means for controlling the heat output, such as flaps and
fans, being set at the highest position, any boost position being ignored
Note 1 to entry: A boost position is a setting of a control for occasional use which results in a higher temporary fan speed.
3.5
maximum storage capacity
Q
max
amount of thermal energy which can be accumulated inside the storage heater, and which is available for space
heating after the heating elements are switched off
3.6
average room temperature
arithmetic average of the maximum and minimum room temperatures for a setting of the room temperature
control
3.7
room temperature control
mechanical or electronic device, sensitive to the room temperature and adjustable by the user
3.8
amplitude
difference between the maximum and the minimum room temperatures for a setting of the room temperature
control
3.9
drift
difference between the average room temperatures obtained at different charge levels for a setting of the
room temperature control
3.10
nominal heat output
P
nom
heat output of a local space heater comprising both direct heat output and indirect heat output (where
applicable), when operating at the setting for the maximum heat output that can be maintained over an
extended period, as declared by the manufacturer, expressed in x,xxx kW
3.11
minimum heat output
P
min
heat output of a local space heater comprising both direct heat output and indirect heat output (where
applicable), when operating at setting of the lowest heat output, as declared by the manufacturer, expressed in
x,xxx kW
3.12
maximum heat output
P
max
declared heat output of an electric local space heater when operating at the setting of the maximum heat
output that can be maintained continuously over an extended period, as declared by the manufacturer,
expressed in x,xxx kW
3.13
electric power consumption in low power modes
P P P P
o, sm, idle, nsm
electric power consumption of the product while in the respective low power mode - off mode, standby mode;
idle mode, or networked standby mode -, expressed in x,xx W
3.14
standby mode
condition where the product is connected to the mains power source and provides only one or more of the
following functions, which may persist for an indefinite time:
a) reactivation function, or reactivation function and indication of enabled reactivation function;
b) reactivation function through a connection to a network (‘networked standby’);
c) information or status display;
Note 1 to entry: In standby mode there is no disconnection from the supply. The status can be indicated by the symbol
ISO 7000/IEC 60417 [5009] or some indication as explained by the manufacturer.
3.15
networked standby
networked standby mode
condition in which the equipment is able to resume a function by way of a remotely initiated trigger from a
network connection;
3.16
reactivation function
function that via a remote switch, a remote control, an internal sensor or timer provides a switch from standby
mode to another mode, including active mode, providing additional functions
3.17
off mode
mode in which the product is connected to the mains power source and is not providing any function, or it is in
a condition providing only:
a) an indication of off mode condition;
b) functionalities intended to ensure electromagnetic compatibility
Note 1 to entry: In the off mode the circuit controlled by the switch is disconnected from the supply.
3.18
idle mode
condition in which the product is connected to the mains power source and is able to automatically provide heat
to the room according to the setpoint temperature
3.19
active mode
condition in which the product is connected to the mains power source and at least one of the main functions
providing the intended service of the equipment has been activated
Note 1 to entry: During charging – i.e. while accumulating thermal energy inside the storage heater – the storage heater is
in an active mode.
3.20
set-back function
function which allows the room temperature to be maintained at a predefined lower value than the pre-set
(comfort) temperature without changing the setting of the room temperature control
3.21
manual heat charge control with integrated thermostat
manually operated sensing device integrated into the product, which measures and regulates its core
temperature to vary the accumulated amount of heat
3.22
manual heat charge control with room and/or external temperature feedback
manually operated sensing device integrated into the product which measures its core temperature and varies
the accumulated amount of heat in relation with the room temperature and/or outdoor temperature
3.23
electronic heat charge control with room and/or external temperature feedback
automatically operated sensing device integrated into the product which measures its core temperature and
varies the accumulated amount of heat in relation with either the outdoor temperature or the heat demand of
the room, or both
3.24
fan assisted heat output
means the product is equipped with an integrated and controllable fan (or fans) to vary the output of the stored
energy according to the heat demand
3.25
mechanical room temperature control
non-electronic device that allows the product to automatically vary its heat output over a certain time period, in
relation to a certain required level of indoor heating comfort
3.26
electronic room temperature control
electronic device, either integrated or external, that allows the product to automatically vary its heat output over
a certain time period, in relation to a certain required level of indoor heating comfort
3.27
electronic room temperature control plus day timer
electronic device, either integrated or external, that allows the
...