Abstract

This document specifies requirements for performance and associated test methods for single-user temporary anchor devices which are not permanently secured to the structure. These anchor devices, intended to be removed from the structure, incorporate stationary or travelling (mobile) anchor points designed for the attachment of suitable components of a personal fall protection system, e.g. in accordance with EN 363:2018.
This document also gives requirements for marking and instructions for use.
This document is not applicable to:
-   anchor devices intended to allow more than one user to be attached at any one time;
-   anchor devices used in any sports or recreational activity;
-   walkways, steps and treads, e.g. equipment conforming to EN 516:2006;
-   permanent anchor devices and roof safety hooks, e.g. equipment conforming to EN 17235:2024;
-   elements or parts of structures which were installed for use other than as anchor points or anchor devices, e.g. beams, girders;
-   structural anchors, e.g. an element that is cast-in, welded, permanently mechanically fixed or bonded by resin to the structure.

Status
Not Published
Public Enquiry End Date
30-Jan-2023
Current Stage
5020 - Formal vote (FV) (Adopted Project)
Start Date
28-Oct-2026
Due Date
16-Dec-2026
Completion Date
28-Oct-2026

Buy Documents

Draft

oSIST prEN 795:2023

English language (51 pages)
Preview
Preview
e-Library read for
×1 day

kSIST FprEN 795:2026 is the Slovenian adoption of the draft European Standard for personal fall protection equipment - anchor devices, published by SIST. It specifies performance requirements, associated test methods, marking, and instructions for use for single-user temporary anchor devices that are not permanently secured to the structure. In practice, it is the document for manufacturers, test laboratories, certifiers, and specifiers who need to check whether an anchor device is suitable for use with a personal fall protection system.

What does kSIST FprEN 795:2026 specify?

kSIST FprEN 795:2026 specifies temporary, single-user anchor devices used as part of a personal fall protection system. The standard covers anchor devices with stationary or travelling anchor points, and it also gives marking requirements, instructions for use, and guidance on installation.

The scope excludes multi-user anchor devices, sports or recreational use, walkways, steps and treads, permanent anchor devices and roof safety hooks, structural elements not designed as anchor points, and structural anchors.

The document is organized into scope, normative references, terms and definitions, requirements, test methods, marking, and manufacturer information, followed by three informative annexes.

AnnexWhat it covers
Annex AExplanatory information on this edition of EN 795
Annex BSignificant technical changes from EN 795:2012
Annex ZARelationship with EU Regulation 2016/425

What are the key requirements of kSIST FprEN 795:2026?

kSIST FprEN 795:2026 focuses on safe attachment, controlled loading, and clear user information. The main point is that an anchor device must stay attached, hold the required load, and behave predictably in the configurations the manufacturer allows.

General design and safety

Clause 4.1 requires the device to be removable from the structure without damage to either the structure or the anchor device, so it can be reused. It also requires that anchor points do not detach unintentionally, and that any removable element or mobile anchor point needs two separate, deliberate manual actions to attach or detach. In practice, this prevents accidental release during use or handling.

Clause 4.1 also requires connectors to rotate freely and sit in the preferred load-bearing position, and it sets a 25 kg limit for any element intended to be carried by one person. If the device has a fall indicator, the indicator must clearly show that a fall has occurred after dynamic testing.

Materials and workmanship

Clause 4.2 requires metal parts to resist corrosion in the salt-spray test, while accepting tarnishing and white scaling if function is not affected. Galvanized steel wire ropes must comply with ISO 2232. Fibre ropes, webbing and sewing threads must be made from man-made fibres with at least the required tenacity, and sewing threads must contrast with the rope or webbing so inspection is easier.

Connectors incorporated in the device must meet the relevant EN 362 requirements. Clause 4.3 also requires the device to avoid sharp edges and burrs that could injure the user or damage PPE. In practice, this means the hardware must be finished and shaped so it does not cut or abrade the system.

Type-specific performance

Clauses 4.4.1 to 4.4.3 set separate performance rules for Type I, Type II and Type III anchor devices.

  • Type I and Type II devices, and Type III devices, must limit permanent deformation of parts intended to deform to 10 mm in the loading direction.
  • Dynamic tests must arrest the rigid test mass and keep it clear of the ground.
  • Static strength tests must hold the load.
  • Where a device has more than one anchor point or more than one permitted configuration, each relevant position or configuration has to be tested.

For Type III devices, the test is more demanding because the device depends on mass and friction on a surface. The standard requires wet-surface dynamic testing, limits the permitted angle from horizontal, and requires the device to remain stationary after arrest. It also sets a post-arrest displacement limit for the leading edge and requires the trailing edge displacement to be measured and recorded in the specified cases.

Flexible anchor lines (FAL) and rigid anchor lines (RAL)

Clauses 4.4.4 and 4.4.5 add requirements when the device includes a flexible anchor line (FAL) or rigid anchor line (RAL). The manufacturer has to provide performance predictions for defined configurations, including maximum deflection and maximum loads at extremity or intermediate supports. That matters because installers need to know how much the line will move and what loads the structure will see.

For FAL assemblies, the mobile anchor point must not detach, the test mass must stay clear of the ground, and the tested performance must stay close to the predicted performance within the stated tolerance. For RAL assemblies, end stops are required, the mobile anchor point must not detach, and if the line may be installed between 5° and 15° from horizontal, the mobile anchor point travel is limited in the test. Non-metallic load-bearing elements are treated more conservatively, with higher static test loads where durability evidence is not provided.

Marking and instructions

Clause 6 requires marking for one user only, the type of anchor device, and the kind of anchor line that can be incorporated if applicable. Clause 7 requires instructions in the destination language, with practical information on use, load transmission to the structure, expected deflection, compatibility issues, inspection of fall indicators, and installation by a trained and competent person.

What terms does kSIST FprEN 795:2026 define?

  • Anchor system - A fall protection system that includes an anchor device and may also include a linking element and/or a structural anchor.
  • Anchor device - An assembly with one or more anchor points or mobile anchor points, temporarily attached to and removable from the structure.
  • Type I anchor device - A device with stationary anchor points that needs a structural anchor to attach it to the structure.
  • Type II anchor device - A device with stationary anchor points that does not need a structural anchor to attach it to the structure.
  • Type III anchor device - A device for surfaces up to 5° from horizontal whose performance relies on mass and friction.
  • Structural anchor - An element permanently incorporated into the structure and not part of the anchor device.
  • Flexible anchor line (FAL) - A flexible line between extremity anchors for connecting personal fall protection equipment.
  • Rigid anchor line (RAL) - A rigid line between extremity anchors for connecting personal fall protection equipment.

Who uses kSIST FprEN 795:2026?

Manufacturers use kSIST FprEN 795:2026 to design and type-test anchor devices before placing them on the market. Test laboratories use it to set up the required deformation, dynamic, static, and corrosion tests.

Certification and conformity assessment bodies use it when evaluating PPE against the stated performance and marking rules. Buyers, safety engineers, and quality managers use it to choose a device type that matches the intended installation, the number of users, and the compatible fall protection system.

Installers and competent persons use it for the information needed to fit the device correctly, especially where FAL, RAL, Type II stability, or Type III surface conditions are involved.

What changed in kSIST FprEN 795:2026 from the previous edition?

kSIST FprEN 795:2026 supersedes EN 795:2012 and updates the standard in several practical ways.

  • The scope is narrowed to anchor devices that are not permanently secured to the structure.
  • New definitions were added for Type I, Type II and Type III anchor devices, together with linking element, locking element, man-made fibre, FAL, and RAL.
  • The former Type A, B, C, D and E terminology was replaced by the current Type I, II and III structure.
  • New requirements were added for devices that include a FAL or RAL.
  • The test masses, test lanyard arrangement, and Type III dynamic test setup were revised.
  • Marking and instructions were expanded to identify the type of anchor line and the relevant installation and compatibility information.
  • Annex A and Annex B were replaced with explanatory material and a summary of technical changes.

Which standards are used with kSIST FprEN 795:2026?

  • EN 360:2002 - referenced for retractable type fall arresters, especially in compatibility and test examples.
  • EN 362:2004 - provides connector requirements for connectors incorporated in anchor devices.
  • EN 363:2018 - defines personal fall protection systems, the system context for these anchor devices.
  • EN 364:1992 - provides test method requirements used for force measurement apparatus.
  • EN 365:2004 - provides the general rules for instructions, maintenance, periodic examination, repair, marking, and packaging.
  • EN 892:2012+A2:2021 - provides the dynamic mountaineering rope used for the test lanyard.
  • EN ISO 9227:2017 - provides the salt spray corrosion test.
  • ISO 2232:1990 - provides specifications for galvanized steel wire rope.
  • EN 39:2001 - provides the scaffold tube used in the Type III dynamic performance test.
  • EN 516:2006, EN 1496:2017, and EN 17235:2024 - appear as related documents for excluded or referenced equipment types.

What does the kSIST FprEN 795:2026 document contain?

The document contains overview tables for anchor device types and test methods, so a reader can match the device design to the correct test route. It also contains detailed test arrangements and apparatus descriptions for dynamic strength, static strength, corrosion resistance, and the special dynamic performance test for Type III devices.

The figures illustrate example anchor devices, flexible and rigid anchor line arrangements, and the test setups used for Type I, Type II, and Type III testing. That makes the document useful for setting up laboratory tests and for understanding how the device is expected to be installed in service.

The annexes add background on the revision, a summary of technical changes from the previous edition, and the relationship with EU Regulation 2016/425.

Relations

Effective Date
18-Jan-2023
Effective Date
17-Oct-2018

Buy Documents

Draft

oSIST prEN 795:2023

English language (51 pages)
Preview
Preview
e-Library read for
×1 day

Get Certified

Connect with accredited certification bodies for this standard

CIS Institut d.o.o.

Personal Protective Equipment (PPE) certification body. Notified Body NB-2890 for EU Regulation 2016/425 PPE.

SA Slovenia Verified

Kiwa BDA Testing

Building and construction product certification.

RVA Netherlands Verified

Kmetijski inštitut Slovenije

Agricultural Institute of Slovenia. Soil testing, plant health, agricultural product analysis.

SA Slovenia Verified

Sponsored listings

Frequently Asked Questions

kSIST FprEN 795:2026 is a draft published by the Slovenian Institute for Standardization (SIST). Its full title is "Personal fall protection equipment - Anchor devices". This standard covers: This document specifies requirements for performance and associated test methods for single-user temporary anchor devices which are not permanently secured to the structure. These anchor devices, intended to be removed from the structure, incorporate stationary or travelling (mobile) anchor points designed for the attachment of suitable components of a personal fall protection system, e.g. in accordance with EN 363:2018. This document also gives requirements for marking and instructions for use. This document is not applicable to: - anchor devices intended to allow more than one user to be attached at any one time; - anchor devices used in any sports or recreational activity; - walkways, steps and treads, e.g. equipment conforming to EN 516:2006; - permanent anchor devices and roof safety hooks, e.g. equipment conforming to EN 17235:2024; - elements or parts of structures which were installed for use other than as anchor points or anchor devices, e.g. beams, girders; - structural anchors, e.g. an element that is cast-in, welded, permanently mechanically fixed or bonded by resin to the structure.

This document specifies requirements for performance and associated test methods for single-user temporary anchor devices which are not permanently secured to the structure. These anchor devices, intended to be removed from the structure, incorporate stationary or travelling (mobile) anchor points designed for the attachment of suitable components of a personal fall protection system, e.g. in accordance with EN 363:2018. This document also gives requirements for marking and instructions for use. This document is not applicable to: - anchor devices intended to allow more than one user to be attached at any one time; - anchor devices used in any sports or recreational activity; - walkways, steps and treads, e.g. equipment conforming to EN 516:2006; - permanent anchor devices and roof safety hooks, e.g. equipment conforming to EN 17235:2024; - elements or parts of structures which were installed for use other than as anchor points or anchor devices, e.g. beams, girders; - structural anchors, e.g. an element that is cast-in, welded, permanently mechanically fixed or bonded by resin to the structure.

kSIST FprEN 795:2026 is classified under the following ICS (International Classification for Standards) categories: 13.340.60 - Protection against falling and slipping. The ICS classification helps identify the subject area and facilitates finding related standards.

kSIST FprEN 795:2026 has the following relationships with other standards: It is inter standard links to SIST EN 795:2012, SIST EN 795:2012. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.

kSIST FprEN 795:2026 is associated with the following European legislation: EU Directives/Regulations: 2016/425; Standardization Mandates: M/031, M/571, M/571 Amd 1, M/571 Amd 2. When a standard is cited in the Official Journal of the European Union, products manufactured in conformity with it benefit from a presumption of conformity with the essential requirements of the corresponding EU directive or regulation.

kSIST FprEN 795:2026 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.

Standards Content (Sample)

Contents

  • Introduction
  • 1 Scope
  • 2 Normative references
  • 3 Terms and definitions
  • 3.1 anchor system
  • 3.2 anchor device
  • 3.2.1 type I anchor device
  • 3.2.2 type II anchor device
  • 3.2.3 type III anchor device
  • 3.3 structural anchor
  • 3.4 linking element
  • 3.5 locking element
  • 3.6 anchor point
  • 3.7 extremity anchor
  • 3.8 intermediate anchor
  • 3.9 mobile anchor point
  • 3.10 man-made fibre
  • 3.11 flexible anchor line
  • 3.12 rigid anchor line
  • 4 Requirements
  • 4.1 General
  • 4.2 Materials
  • 4.3 Design and ergonomics
  • 4.4 Specific requirements
  • 4.5 Marking and information
  • 5 Test methods
  • 5.1 General
  • 5.2 Test arrangement and apparatus
  • 5.3 Type I anchor device
  • 5.4 Type II anchor devices
  • 5.5 Type III anchor devices
  • 5.6 Corrosion resistance
  • 6 Marking
  • 7 Manufacturer’s instructions and information
  • Annex A
  • 1 Scope Taking into account that permanent anchor devices are
  • 3 Terms and definitions To take into account that different types of anchors
  • 6 Marking To reflect the combination of a flexible and/or rigid
  • Annex B
  • 1 Scope This document applies to single-user anchor devices that are
  • 2 Normative references Reference to EN 39:2001 added. Date references added to
  • 4 Requirements
  • 5 Test methods
  • 5.3 Type I anchor device replaces type A anchor device
  • 6 Marking
  • 7 Manufacturer’s instructions and
  • Annex A Annex A covering explanatory information replaces previous
  • Annex A covering information on installation documentation
  • Annex B New Annex B covering significant technical changes replaces
  • Annex ZA
  • Annex II
  • 1.4 Manufacturer’s instructions 4.5 4.5 refers to the information required in
  • 2.4 PPE subject to ageing 4.5 4.5 refers to Clause 7, which in turn refers
  • 2.8 PPE for intervention in very 4.5 4.5 refers to Clause 7, which in turn refers
  • 2.12 PPE bearing one or more 4.5 4.5 refers to the information required in
  • Annex II
  • Bibliography

Introduction

A reliable anchor device is an essential component of any personal fall protection system. This document is intended to act as a complementary standard for existing European Standards covering other components used in personal fall protection systems.

The scope and the requirements are based on the philosophy that anchor devices are rated to sustain the maximum dynamic force generated in a fall from a height by the mass of one person, including any equipment carried. The static strength tests are based on a minimum factor of safety of two. To allow for foreseeable misuse of equipment, this document provides requirements and test methods for anchor devices used in personal fall protection systems in accordance with EN 363:2018, even if their intended use is for restraint.

Requirements and test methods for multi-user anchor devices, i.e. anchor devices that allow more than one user to be attached at any one time, are not addressed in this document but advice is provided in a separate CEN Technical Specification.

This document is intended for the type testing of new products before placing them on the market and gives only minimum performance requirements. It is essential that anchor devices are designed and manufactured so that, in the foreseeable conditions of use for which they are intended, the user is able to perform the risk-related activity while being appropriately protected at the highest possible level. Manufacturers may wish to bear these points in mind when deciding on the actual performance of their products.

oSIST prEN 795:2023 prEN 795:2022 (E)

1 Scope

This document specifies requirements for performance and associated test methods for single-user anchor devices which are not permanently secured to the structure. These anchor devices incorporate stationary or travelling (mobile) anchor points designed for the attachment of components of a personal fall protection system in accordance with EN 363:2018.

This document also gives requirements for marking and instructions for use, and guidance on installation. This document is not applicable to:

  • anchor devices intended to allow more than one user to be attached at any one time;
  • anchor devices used in any sports or recreational activity;
  • equipment designed to conform to EN 516:2006;
  • permanent anchor devices and roof safety hooks conforming to EN 17235 ;
  • elements or parts of structures which were installed for use other than as anchor points or anchor devices, e.g. beams, girders;
  • structural anchors (see 3.3).

2 Normative references

The following documents are referred to in the text in such a way that some or all of their content constitutes requirements of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 360:2002, Personal protective equipment against falls from a height - Retractable type fall arresters EN 362:2004, Personal protective equipment against falls from a height - Connectors EN 363:2018, Personal fall protection equipment - Personal fall protection systems EN 364:1992, Personal protective equipment against falls from a height - Test methods EN 365:2004, Personal protective equipment against falls from a height - General requirements for instructions for use, maintenance, periodic examination, repair, marking and packaging EN 892:2012+A2:2021, Mountaineering equipment — Dynamic mountaineering ropes — Safety requirements and test methods EN ISO 9227:2017, Corrosion tests in artificial atmospheres - Salt spray tests (ISO 9227:2017) ISO 2232:1990, Round drawn wire for general purpose non-alloy steel wire ropes and for large diameter steel wire ropes — Specifications EN 39:2001, Loose steel tubes for tube and coupler scaffolds - Technical delivery conditions

1 Under preparation. Stage at the time of publication: prEN 17235:2018.

oSIST prEN 795:2023 prEN 795:2022 (E)

3 Terms and definitions

For the purposes of this document, the following terms and definitions apply. ISO and IEC maintain terminological databases for use in standardization at the following addresses:

  • ISO Online browsing platform: available at http://www.iso.org/obp
  • IEC Electropedia: available at http://www.electropedia.org/

3.1 anchor system

system intended for use as part of a personal fall protection system that incorporates an anchor device and/or a linking element and/or a structural anchor (see Figure 1) Note 1 to entry: Items shown in light grey in all figures throughout this standard are structural parts which are not covered by this standard and shown for clarity only.

a) b)

c) d) Key 1 anchor point 4 anchor device 2 structure (not part of the anchor device) 5 structural anchor, e.g. mechanically or resin fixed (not part of the anchor device) 3 linking element Figure 1 — Examples of anchor systems that include an anchor device

3.2 anchor device

assembly of elements which incorporates one or more anchor points or mobile anchor points that can include a linking element, is intended for use as part of a personal fall protection system and is designed to be temporarily attached to and removable from the structure and to be part of the anchor system

oSIST prEN 795:2023 prEN 795:2022 (E)

3.2.1 type I anchor device

anchor device with one or more stationary anchor points with the need for a structural anchor/structural anchors to attach it to the structure (see Figure 2) and which may include a flexible or rigid anchor line (see Figure 5a) with or without a mobile anchor point Note 1 to entry: Anchor points may rotate or swivel when in use, where they are designed to do so. Note 2 to entry: A stand-alone FAL can be a type I anchor device (see Figure 7). Note 3 to entry: A davit can be a type 1 anchor device (see Figure 2c).

3.2.2 type II anchor device

anchor device with one or more stationary anchor points without the need for a structural anchor/structural anchors to attach it to the structure (see Figure 3) and which may include a flexible or rigid anchor line (see Figure 5b and Figure 6) with or without a mobile anchor point Note 1 to entry: Anchor points may rotate or swivel when in use, where they are designed to do so. Note 2 to entry: A tripod, quadpod, gantry or davit are examples of a type II anchor device with legs (see Figures 3a and 3e).

3.2.3 type III anchor device

anchor device for use on surfaces up to 5° from the horizontal with one or more stationary anchor points where the performance relies solely on mass and friction between itself and the surface (see Figure 4) and which may include a flexible or rigid anchor line (see Figure 5c) with or without a mobile anchor point Note 1 to entry: Anchor points may rotate or swivel when in use, where they are designed to do so.

3.3 structural anchor

element or elements which are designed for use in conjunction with a personal fall protection system and to be permanently incorporated into a structure Note 1 to entry: A structural anchor is not part of the anchor device. Note 2 to entry: Examples of a structural anchor is a permanent anchor device conforming to EN 17235 or an element that is cast-in, welded, mechanically or bonded by resin to the structure.

3.4 linking element

element or elements of the anchor device used to connect/fix the anchor device to the structure, and which is/are removable from the structure Note 1 to entry: A connector conforming to EN 362 can be a linking element.

3.5 locking element

element or elements which is an integral part(s) of the anchor device used to lock the anchor device to the structure or the structural anchor

oSIST prEN 795:2023 prEN 795:2022 (E)

3.6 anchor point

point on an anchor device where personal fall protection equipment is intended to be attached

3.7 extremity anchor

type I, II or III anchor device which connects the extremity of a flexible anchor line or rigid anchor line onto the structure

3.8 intermediate anchor

type I, II or III anchor device or other element located between the extremity anchors, which connects a flexible anchor line or a rigid anchor line onto the structure Note 1 to entry: Intermediate supports, e.g. a flexible anchor line guide, which are not intended to withstand the load, are not intermediate anchors.

3.9 mobile anchor point

element with an anchor point which is intended to travel along an anchor line

3.10 man-made fibre

fibre obtained by a manufacturing process Note 1 to entry: Man-made fibres refer to ISO/TR 11827:2012.

3.11 flexible anchor line

FAL flexible line between extremity anchors to which personal fall protection equipment can be attached either directly by a connector or through a mobile anchor point, which deviates from the horizontal by not more than 15° (when measured between the extremity and intermediate anchors at any point along its length) Note 1 to entry: A flexible anchor line can be a wire rope, fibre rope, or webbing. Note 2 to entry: Extremity and intermediate anchors can be a type I, type II or type III anchor device.

3.12 rigid anchor line

RAL rigid line between extremity anchors to which personal fall protection equipment can be attached either directly by a connector or through a mobile anchor point, which deviates from the horizontal by not more than 15° (when measured between the extremity and intermediate anchors at any point along its length) Note 1 to entry: A rigid anchor line can be a rigid profile, e.g. a rigid tube or rigid rail. Note 2 to entry: Extremity and intermediate anchors can be a type I, type II or type III anchor device.

oSIST prEN 795:2023 prEN 795:2022 (E)

a) Eyebolt b) Eyebolt

c) Davit Key 1 anchor point 3 structure 5 structural anchor 2 anchor 4 locking device element Figure 2 — Examples of type I anchor devices with a locking element and a structural anchor

oSIST prEN 795:2023 prEN 795:2022 (E)

a) Tripod b) Sling

c) Door anchor d) Beam anchor

e) Davit (freestanding or counterweighted) f) Eyebolt Key 1 anchor point 3 structure 2 anchor device 4 locking element Figure 3 — Examples of type II anchor devices

oSIST prEN 795:2023 prEN 795:2022 (E)

Key 1 anchor point 3 structure 2 mass Figure 4 — Example of a type III anchor device

a) Type I anchor device including a FAL

b) Type II anchor device including a FAL

c) Type III anchor device including a FAL Key 1 extremity anchor 3 intermediate anchor 5 adjusting device 2 flexible anchor line 4 mobile anchor point Figure 5 — Examples of a type I, II and III anchor devices with a FAL

oSIST prEN 795:2023 prEN 795:2022 (E)

Key 1 extremity or intermediate anchor (e.g. clamping 3 rigid anchor line 5 end stop bracket) joiner 2 mobile anchor point 4 rigid anchor line Figure 6 — Example of a type II anchor device with a RAL

Key 1 linking element 3 flexible anchor line 2 adjusting device 4 mobile anchor point Figure 7 — Example of a stand-alone FAL as a type I anchor device

oSIST prEN 795:2023 prEN 795:2022 (E)

4 Requirements

4.1 General

Table 1 — Overview of anchor devices and types Type Examples of anchor devices I II III Comments Eyebolt (requiring structural

anchor) Eyebolt (not requiring

structural anchor) Anchor Sling

Door Anchor

Beam Anchor

FAL can be combined with type Flexible Anchor Line

I, II and III anchor devices RAL can be combined with type Rigid Anchor Line

I, II and III anchor devices Tripod (quadpod, gantry)

Mass friction (deadweight)

anchor Davit (structural socket) See Note 2

Davit See Note 2

(freestanding/counterweight) NOTE See Annex A for additional information on types of anchor devices. A davit arm which is removable and can be used either with a type 1 structural socket, or a type 2 freestanding socket should be tested as a type I and type II anchor device. 4.1.1 When checked in accordance with 5.1.7, anchor devices shall be designed in such a way that they can be removed from the structure without damaging the structure or the anchor device, thus allowing its reuse.

4.1.2 When checked in accordance with 5.1.7, U-bolt clamps including those conforming to EN 13411-5 shall not be used to form a termination in the flexible anchor line. 4.1.3 When checked in accordance with 5.1.7, it shall not be possible for elements with an anchor point to become detached unintentionally. If the element or mobile anchor point can be removed, it shall be designed such that it can only be attached and detached after executing two separate, consecutive and deliberate manual actions.

4.1.4 When checked in accordance with 5.1.7, anchor devices shall be of such a design and size to allow connectors to rotate freely and sit in the anchor point in the preferred load bearing position.

4.1.5 When checked in accordance with 5.1.7, elements shall not appear to be positively locked

together when incorrectly assembled, adjusted or fitted, e.g. when adjusting and locking the legs of a tripod, when fitting and removing an eyebolt.

oSIST prEN 795:2023 prEN 795:2022 (E)

4.1.6 When checked in accordance with 5.1.7, the mass of any element of an anchor device that is

intended to be transported by a single person shall not exceed 25 kg. 4.1.7 If the anchor device is equipped with a fall indicator, the indicator shall clearly indicate a fall has occurred after the dynamic strength test(s).

4.1.8 Where the information provided by the manufacturer permits loading in more than one direction (e.g. in tension and in shear) anchor devices shall be tested in each safety critical direction (see 7 c).

4.2 Materials

4.2.1 Metal parts

4.2.1.1 After testing in accordance with 5.6, there shall be no corrosion of the base material. The presence of tarnishing and white scaling is acceptable. Metal parts of anchor devices shall show no evidence of corrosion that would affect their functional operation, e.g. the correct operation of moving elements.

NOTE Conformity to this requirement does not imply suitability for use in a marine environment.

4.2.1.2 If steel wire ropes are galvanised, the galvanisation shall be in accordance with

ISO 2232:1990.

4.2.2 Rope and webbing
4.2.2.1 When checked in accordance with 5.1.7, fibre ropes, webbing and sewing threads shall be

made from man-made fibres with a tenacity of at least 0,6 N/tex. NOTE 1 0,6 N/tex is based on the information given in EN ISO 9554:2019, Annex A. NOTE 2 Examples of suitable materials for use in rope and webbing are polyamide, polyester and mixtures of polyamide and polyester.

4.2.2.2 When checked in accordance with 5.1.7, threads used for sewing shall be of a contrasting

shade or colour when compared to the rope or webbing to facilitate visual inspection.

4.2.3 Connectors

When checked in accordance with 5.1.7, connectors incorporated in anchor devices shall meet the requirements of EN 362:2004, 4.1 to 4.5.

4.3 Design and ergonomics

When checked in accordance with 5.1.7, anchor devices shall not have sharp edges or burrs that may cause injury to the user or that may cut, abrade or otherwise damage itself or any part of the personal fall protection equipment that may come into contact with it.

It is recommended that exposed edges or corners of elements are relieved either with a radius of at least 0,5 mm or a chamfer of at least 0,5 mm × 45°.

oSIST prEN 795:2023 prEN 795:2022 (E)

4.4 Specific requirements

4.4.1 Type I anchor devices
4.4.1.1 When tested in accordance with 5.3.2 (deformation test), no part of a type I anchor device

which is intended to deform, e.g. to absorb energy, shall demonstrate permanent deformation of more than 10 mm in the direction of loading.

NOTE The test is to check resistance to deformation and does not represent the weight of the user.

4.4.1.2 When tested in accordance with 5.3.3 (dynamic strength test), the anchor device shall not

release the rigid test mass and the rigid test mass shall be held clear of the ground. 4.4.1.3 When tested in accordance with 5.3.4 (static strength test), the anchor device shall hold the load.

4.4.1.4 Where the anchor device has more than one anchor point repeat the tests in 5.3.2 to 5.3.4 for each anchor point.

4.4.2 Type II anchor devices

4.4.2.1 When tested in accordance with 5.4.2 (deformation test), no part of a type II anchor device, excluding rope and webbing slings manufactured from man-made fibres, which is intended to deform, e.g. to absorb energy, shall demonstrate permanent deformation of more than 10 mm in the direction of loading.

NOTE The test is to check resistance to deformation and does not represent the weight of the user.

4.4.2.2 When tested in accordance with 5.4.3 (dynamic strength test), the anchor device shall not

release the rigid test mass and the rigid test mass shall be held clear of the ground. 4.4.2.3 When tested in accordance with 5.4.4 (static strength test), the anchor device shall hold the load.

4.4.2.4 Where the information provided by the manufacturer permits use in more than one

configuration, e.g. a tripod or quadpod with anchor points at the head and on a leg, each configuration shall be tested and meet the requirements of 4.4.2.1 to 4.4.2.3. If a type II anchor device (e.g. a tripod) is intended to be used with a rescue lifting device (see EN 1496:2017), it is recommended that the whole unit should meet the following requirements:

4.1 General, 4.2 Materials, 4.3 Design and ergonomics and 4.4.2 Type II anchor devices.

4.4.3 Type III anchor devices

4.4.3.1 When tested in accordance with 5.5.2 (deformation test), no part of the anchor device which is intended to deform, e.g. to absorb energy, shall demonstrate permanent deformation of more than 10 mm in the direction of loading.

NOTE The test is to check resistance to deformation and does not represent the weight of the user.

4.4.3.2 When tested in accordance with 5.5.3 (dynamic performance test), at the maximum angle the

manufacturer permits with a limit of 5° under wet conditions, the anchor device shall not release the rigid test mass and the rigid test mass shall be held clear of the ground. Three min after the drop test, the displacement L of the leading edge of the anchor device shall not exceed 1 000 mm and the anchor device shall remain stationary. The displacements L and H shall be recorded (see Figure 11).

oSIST prEN 795:2023 prEN 795:2022 (E)

4.4.3.3 When tested in accordance with 5.5.3.1.4 to 5.5.3.1.7 (post-arrest suspension test), the

leading edge of the anchor device where it is in contact with the surface shall not displace more than 10,0 mm after a period of 3 min, after which it shall remain stationary. 4.4.3.4 When tested in accordance with 5.5.4 (static strength test), the anchor point shall hold the load.

4.4.4 Type I, II and III anchor devices including a FAL
4.4.4.1 When type I, II and III anchor devices include a FAL the following additional requirements

shall be met.

4.4.4.2 When tested in accordance with 5.3.2.2, 5.4.2.2 or 5.5.2.2 (deformation test), no part of the extremity anchors, intermediate anchors or mobile anchor point which is intended to deform, i.e. to absorb energy, shall demonstrate permanent deformation of more than 10 mm in the direction of loading.

4.4.4.3 Performance predictions based on calculations or test results shall be available for

configurations of anchor devices and FAL as described in 5.3.1.2.1, including information on:

...