Fibre organisers and closures to be used in optical fibre communication systems - Product specifications - Part 3-5 Wall outlet

This European Standard covers wall outlets for up to 4 SC foot-print adapters. Various connector types (e.g.
SC, LC) can be implemented as long as the adapter fits in the SC foot-print dimensions.
A Wall Outlet is the passive end connection point of a fixed Single Mode fibre based FTTH network to the
flexible network of service unit (CPE, ONT) indoor. Products defined by IEV 442-08-02 or IEV 723-09-22 can
be considered as Wall Outlets. SI or ENTI are not part of this wall outlet specification.
This specification also covers the possibility of using hybrid (fibre/copper) wall outlets with 1 RJ-45 footprint.
Performance of copper cabling and connectivity is not in the scope of this document, but should be verified in
line with EN 50346.
Wall outlets are placed in end user premises by installers and the contents are not intended to be user
accessible. Wall outlets may be mounted using a number of techniques: surface mounted on a wall, patress
boxes, trunking or raceway; flush mounted or between cable trunking. Cable entry points vary with mounting
method: surface mounted or flush mounted boxes may require large holes at the rear of the wall outlet for
cable entry requiring little or no strain relief, whereas boxes with cable entry visible to the end user will need
cable sealing and strain relief.
Wall outlets covered in the product specification will include a fibre management system (FMS) for managing
the incoming cables or fibres. The FMS may include trays for splicing pigtails to incoming cable/fibre.
This European Standard contains the initial, start of life dimensional, optical, mechanical and environmental
performance requirements of an optical fibre wall outlet, in order for it to be categorized as an European
Standard product.

LWL-Spleißkassetten und Muffen für die Anwendung in LWL-Kommunikationssystemen – Produktspezifikationen – Teil 3-5: Wandanschlussdose

Organiseurs et boîtiers de fibres à utiliser dans les systèmes de communication par fibres optiques - Spécifications de produits - Partie 3-5: Prise murale

1.1   Définition du produit La présente spécification couvre les prises murales pour les raccords d'un encombrement allant jusqu'à 4 SC. Divers types de connecteurs (par exemple, SC, LC) peuvent être mis en œuvre dans la mesure où le raccord s'ajuste dans les dimensions d'un encombrement SC. Une prise murale constitue le point de connexion d'extrémité passif d'un réseau de FTTH (Fibre jusqu'au logement, en anglais « Fibre to the home ») à fibres unimodales avec l'unité flexible de réseau ou de service (CPE, ONT) intérieure. Celle-ci couvre les définitions 442-08-02 du VEI, 723-09-22 du VEI, et de l'ISO 11801. Cette spécification couvre également les prises murales facultatives hybrides (fibre optique/cuivre) d'encombrement RJ-45. Les performances de câblage et de connectivité du cuivre ne font pas partie du domaine d'application du présent document mais il convient de les considérer en relation avec la EN 50346 Installation de câblage -Essai des câblages installés  (Voir la relation à l'Annexe C). La présente spécification contient les exigences de performances initiales, dimensionnelles, optiques, mécaniques et environnementales, de début de vie, des prises murales pour fibres optiques, afin d'être classée comme produit conforme à une norme EN. 1.2   Environnement de fonctionnement Les essais sélectionnés combinés avec la sévérité et la durée sont représentatifs d'une installation intérieure et extérieure pour des environnements au-dessus du sol définis par: la CEI 61753-1    catégorie C - Environnement contrôlé 1.3   Fiabilité Tandis que l'espérance de vie du produit en service prévue dans cet environnement est de 20 ans, la conformité à la présente spécification ne garantit pas la fiabilité du produit. Il convient que celle-ci soit estimée en utilisant un programme reconnu d'évaluation de la fiabilité. 1.4   Assurance de la qualité La conformité à la présente spécification ne garantit pas la cohérence de fabrication du produit. Il convient qu’elle soit suivie en utilisant un programme reconnu d'assurance de la qualité. 1.5   Types de fibres et de câbles autorisés Toutes les fibres selon la EN 60793-2-50 sont autorisées dans les prises murales avec un rayon de stockage minimal de 20 mm jusqu'à une longueur de 2 m. Jusqu'à 2 m de fibres B6 selon la EN 60793-2-50 stockées avec un rayon de courbure minimal de 15 mm satisfont à la limite de probabilité de défaillance mécanique de 10-5. Dans ce cas, on peut s'attendre à une perte de courbure supplémentaire allant jusqu'à 0,5 dB à 1550 nm et 2 dB à 1625 nm pour le type de fibre B6_a1 Cette perte supplémentaire est réduite soit en diminuant la longueur stockée, soit en utilisant une fibre moins sensible aux courbures. L'utilisation d'un câble hybride est facultative; on peut trouver les spécifications des câblages en cuivre dans les documents EN correspondants (voir l'Annexe C).

Delilniki za optična vlakna in kabelske spojnice za optične komunikacijske sisteme - Specifikacije izdelkov - 3-5. del: Zidna vtičnica

Ta evropski standard obravnava zidne vtičnice za do 4 prilagodilnike s tlorisom SC. Če prilagodilnik ustreza meram tlorisa SC, je mogoča uporaba različnih tipov konektorjev (npr. SC in LC).
Zidna vtičnica je pasivna končna točka zveze med fiksnim omrežjem FTTH z enorodnim optičnim kablom in
prilagodljivim omrežjem storitvene enote (CPE, ONT) v prostoru. Izdelke, opredeljene v IEV 442-08-02 ali IEV 723-09-22, je mogoče upoštevati kot zidne vtičnice. SI ali ENTI nista del specifikacije te zidne vtičnice.
Ta specifikacija obravnava tudi možnost uporabe hibridnih (optičnih/bakrenih) zidnih vtičnic s tlorisom 1 konektorja RJ-45. Zmogljivost bakrenih kablov in njihove povezljivosti ni vključena v ta dokument, vendar naj bi se preverilo, ali je v skladu s standardom EN 50346.
Zidne vtičnice namestijo v prostorih končnega uporabnika monterji in vsebina ni namenjena
dostopu uporabnikov. Zidne vtičnice se lahko montira na številne načine: z montažo na površino zidu, v dozo, korito ali tečišče; ugreznjeno ali med kabelskimi koriti. Kabelske uvodnice se razlikujejo glede na način montaže: doze, ki so montirane na površino zidu ali vgreznjeno, lahko zahtevajo velike odprtine na zadnji strani zidne vtičnice za kabelsko uvodnico, ki potrebuje nekaj razbremenilnih sponk ali jih ne potrebuje, medtem ko doze s kabelsko uvodnico, ki je vidna končnemu uporabniku, potrebujejo tesnilo in razbremenilne sponke.
Zidne vtičnice, ki so obravnavane v specifikaciji izdelka, vključujejo sistem upravljanja z optičnimi kabli (FMS) za upravljanje dovodnih kablov ali optičnih vlaken. Sistem upravljanja z optičnimi kabli lahko vključuje pladnje za spajanje zaključkov in dovodnih kablov/optičnih vlaken. Ta evropski standard vsebuje začetne dimenzijske, optične, mehanske in okoljske funkcionalne zahteve, ki jih mora na začetku življenjske dobe izpolnjevati zidna vtičnica z optičnimi vlakni, da se lahko kategorizira kot izdelek v skladu z evropskim standardom.

General Information

Status
Published
Public Enquiry End Date
25-Jul-2013
Publication Date
08-Feb-2016
Technical Committee
Current Stage
6060 - National Implementation/Publication (Adopted Project)
Start Date
18-Dec-2015
Due Date
22-Feb-2016
Completion Date
09-Feb-2016

Buy Standard

Standard
EN 50411-3-5:2016
English language
22 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

SLOVENSKI STANDARD
SIST EN 50411-3-5:2016
01-april-2016
'HOLOQLNL]DRSWLþQDYODNQDLQNDEHOVNHVSRMQLFH]DRSWLþQHNRPXQLNDFLMVNHVLVWHPH
6SHFLILNDFLMHL]GHONRYGHO=LGQDYWLþQLFD
Fibre organisers and closures to be used in optical fibre communication systems -
Product specifications - Part 3-5 Wall outlet
Ta slovenski standard je istoveten z: EN 50411-3-5:2015
ICS:
33.180.20 3RYH]RYDOQHQDSUDYH]D Fibre optic interconnecting
RSWLþQDYODNQD devices
SIST EN 50411-3-5:2016 en
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------

SIST EN 50411-3-5:2016

---------------------- Page: 2 ----------------------

SIST EN 50411-3-5:2016

EUROPEAN STANDARD EN 50411-3-5

NORME EUROPÉENNE

EUROPÄISCHE NORM
December 2015
ICS 33.180.20
English Version
Fibre organisers and closures to be used in optical fibre
communication systems - Product specifications - Part 3-5: Wall
outlet
Organiseurs et boîtiers de fibres à utiliser dans les LWL-Spleißkassetten und Muffen für die Anwendung in
systèmes de communication par fibres optiques - LWL-Kommunikationssystemen - Produktspezifikationen -
Spécifications de produits - Partie 3-5: Prise murale Teil 3-5: Wandanschlussdose
This European Standard was approved by CENELEC on 2015-06-15. CENELEC members are bound to comply with the CEN/CENELEC
Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC
Management Centre or to any CENELEC member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation
under the responsibility of a CENELEC member into its own language and notified to the CEN-CENELEC Management Centre has the
same status as the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic,
Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia,
Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland,
Turkey and the United Kingdom.



European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels
© 2015 CENELEC All rights of exploitation in any form and by any means reserved worldwide for CENELEC Members.
 Ref. No. EN 50411-3-5:2015 E

---------------------- Page: 3 ----------------------

SIST EN 50411-3-5:2016
EN 50411-3-5:2015
Contents Page
European foreword .3
1 Scope .5
1.1 Product definition .5
1.2 Operating environment .5
1.3 Reliability .5
1.4 Quality assurance .5
1.5 Allowed fibre and cable types .6
2 Normative references .6
3 Terms, definitions and abbreviations .7
3.1 Terms and definitions .7
3.2 Abbreviations .7
4 Description .7
4.1 Optical fibre wall outlet .7
4.2 Optical fibre minimum storage and bending radius .9
4.3 Cable fixing .9
4.4 FMS system .9
4.5 Materials .9
4.6 Laser safety .9
4.7 Marking and identification .9
5 Variants . 10
6 Dimensional requirements . 11
7 Tests . 11
7.1 Test sample size . 11
7.2 Test sample preparation . 11
7.3 Test and measurement methods. 12
7.4 Test sequence . 12
7.5 Pass/fail criteria . 12
8 Test report . 13
9 Performance requirements . 13
9.1 Dimensional and marking requirements . 13
9.2 Ingress, optical and appearance performance criteria . 13
9.3 Mechanical ingress performance requirements . 14
9.4 Environmental ingress performance requirements . 15
9.5 Mechanical optical performance requirements . 15
9.6 Environmental optical performance requirements . 16
9.7 Material performance requirements . 17
Annex A (informative) Fibre for test sample details . 18
Annex B (normative) Sample size and product sourcing requirements . 19
Annex C (informative) Relationship of EN 50346 with other copper cabling standards . 20
Bibliography . 21

2

---------------------- Page: 4 ----------------------

SIST EN 50411-3-5:2016
EN 50411-3-5:2015
European foreword
This document (EN 50411-3-5:2015) has been prepared by CLC/TC 86BXA "Fibre optic interconnect,
passive and connectorised components".
The following dates are fixed:
• latest date by which this document has (dop) 2016-06-11
to be implemented at national level by
publication of an identical national
standard or by endorsement
• latest date by which the national (dow) 2018-06-15
standards conflicting with this
document have to be withdrawn
EN 50411, Fibre organisers and closures to be used in optical fibre communication systems — Product
specifications, is currently composed of the following parts:
— Part 2: General and guidance for optical fibre cable joint closures, protected microduct closures, and
microduct connectors;
— Part 2-2: Sealed pan fibre splice closures Type 1, for category S & A;
— Part 2-3: Sealed inline fibre splice closures Type 1, for category S & A;
— Part 2-4: Sealed dome fibre splice closures Type 1, for category S & A;
— Part 2-5: Sealed closures for air blown fibre microduct, type 1, for category S & A;
— Part 2-8: Microduct connectors, for air blown optical fibres, Type 1;
— Part 2-9: Non-sealed closures for air blown fibre microduct cable, for category S & A;
— Part 2-10: Sealed fibre splice closures type 2, category G, for FTTH optical distribution networks;
— Part 3-1: Fibre management system, splice wall box, for category C & G;
— Part 3-2: Singlemode mechanical fibre splice;
— Part 3-3: Singlemode optical fibre fusion splice protectors;
— Part 3-4: Fibre management system, modular splice and connector wall box, for category C & A
[currently at Enquiry stage];
— Part 3-5: Wall outlet [the present document];
— Part 3-6: Multimode mechanical fibre splice for use in an outdoor protected environment (Cat U);
3

---------------------- Page: 5 ----------------------

SIST EN 50411-3-5:2016
EN 50411-3-5:2015
— Part 3-8: Fibre management system, terminal equipment box type 1 for category C [currently at Formal
Vote stage];
— Part 6-1: Unprotected microduct for category S and A.
Attention is drawn to the possibility that some of the elements of this document may be the subject of patent
rights. CENELEC [and/or CEN] shall not be held responsible for identifying any or all such patent rights.
Fibre organisers and closures to be used in optical fibre communication systems – Product
specifications
Part 3-5: Fibre management system, FTTH wall outlet, for category C
Description Performance
Construction: Wall /Flush/Trunking mounted Applications:
outlet
Fibre line termination in FTTH networks for indoor
Cable Fixing: Mechanical controlled environments EN 61753-1 Category C
Connector: EN 50377 series Sealing performance: IP 40
EN 60603-7 series
Fibre types: EN 60793-2-50, B1 and B6
Fibre management: Integrated in wall outlet
Related documents:
EN 60529 Degrees of protection provided by enclosures (IP Code) (IEC 60529)
EN 60793-2-50 Optical fibres — Part 2-50: Product specifications — Sectional specification for class B
single-mode fibres (IEC 60793-2-50)
EN 61753-1 Fibre optic interconnecting devices and passive components — Part 1: General and
guidance for performance standard (IEC 61753-1)
EN 61300 series Fibre optic interconnecting devices and passive components — Basic test and
measurement procedures (IEC 61300 series)
Maximum outline
Shape
dimensions
Width: 150 mm
Height: 210 mm
Depth: 60 mm


4

---------------------- Page: 6 ----------------------

SIST EN 50411-3-5:2016
EN 50411-3-5:2015
1 Scope
1.1 Product definition
This European Standard covers wall outlets for up to 4 SC foot-print adapters. Various connector types (e.g.
SC, LC) can be implemented as long as the adapter fits in the SC foot-print dimensions.
A Wall Outlet is the passive end connection point of a fixed Single Mode fibre based FTTH network to the
flexible network of service unit (CPE, ONT) indoor. Products defined by IEV 442-08-02 or IEV 723-09-22 can
be considered as Wall Outlets. SI or ENTI are not part of this wall outlet specification.
This specification also covers the possibility of using hybrid (fibre/copper) wall outlets with 1 RJ-45 footprint.
Performance of copper cabling and connectivity is not in the scope of this document, but should be verified in
line with EN 50346.
Wall outlets are placed in end user premises by installers and the contents are not intended to be user
accessible. Wall outlets may be mounted using a number of techniques: surface mounted on a wall, patress
boxes, trunking or raceway; flush mounted or between cable trunking. Cable entry points vary with mounting
method: surface mounted or flush mounted boxes may require large holes at the rear of the wall outlet for
cable entry requiring little or no strain relief, whereas boxes with cable entry visible to the end user will need
cable sealing and strain relief.
Wall outlets covered in the product specification will include a fibre management system (FMS) for managing
the incoming cables or fibres. The FMS may include trays for splicing pigtails to incoming cable/fibre.
This European Standard contains the initial, start of life dimensional, optical, mechanical and environmental
performance requirements of an optical fibre wall outlet, in order for it to be categorized as an European
Standard product.
1.2 Operating environment
The tests selected combined with the severity and duration is representative of indoor environments defined
by:
EN 61753-1 category C Controlled environment
1.3 Reliability
Whilst the anticipated service life expectancy of the product in this environment is 20 years, compliance with
this specification does not guarantee the reliability of the product. This should be predicted using a
recognized reliability assessment programme.
1.4 Quality assurance
Compliance with this specification does not guarantee the manufacturing consistency of the product. This
should be maintained using a recognized quality assurance programme.
5

---------------------- Page: 7 ----------------------

SIST EN 50411-3-5:2016
EN 50411-3-5:2015
1.5 Allowed fibre and cable types
All EN 60793-2-50 fibres can be stored in the Wall Outlet with a minimum storage radius of 20 mm (up to a
storage length of maximum 2 m).
Smaller storage radii down to 15 mm are possible with the EN 60793-2-50 B6_a fibre types, but in this case
the reduction in mechanical reliability should be taken into account (see 4.2). If hybrid cable is used then only
the fibre portion is considered in this product specification.
2 Normative references
The following documents, in whole or in part, are normatively referenced in this document and are
indispensable for its application. For dated references, only the edition cited applies. For undated references,
the latest edition of the referenced document (including any amendments) applies.
EN 50377 (all parts), Connector sets and Interconnect components to be used in optical fibre communication
systems — Product specification
EN 60529, Degrees of protection provided by enclosures (IP Code) (IEC 60529)
EN 60695-11-10, Fire hazard testing — Part 11-10: Test flames — 50 W horizontal and vertical flame test
methods (IEC 60695-11-10)
EN 60754-1, Test on gases evolved during combustion of materials from cables — Part 1: Determination of
the halogen acid gas content (IEC 60754-1)
EN 60793-2-50, Optical fibres — Part 2-50: Product specifications — Sectional specification for class B
single-mode fibres (IEC 60793-2-50)
EN 60825-2, Safety of laser products — Part 2: Safety of optical fibre communication systems (OFCS)
(IEC 60825-2)
EN 61034-2, Measurement of smoke density of cables burning under defined conditions — Part 2: Test
procedure and requirements (IEC 61034-2)
EN 61300-2-1:2009, Fibre optic interconnecting devices and passive components — Basic test and
measurement procedures — Part 2-1: Tests — Vibration (sinusoidal)(IEC 61300-2-1:2009)
EN 61300-2-4, Fibre optic interconnecting devices and passive components — Basic test and measurement
procedures - Part 2-4: Tests — Fibre/cable retention (IEC 61300-2-4)
EN 61300-2-9, Fibre optic interconnecting devices and passive components — Basic test and measurement
procedures — Part 2-9: Tests — Shock (IEC 61300-2-9)
EN 61300-2-12:2009, Fibre optic interconnecting devices and passive components — Basic test and
measurement procedures — Part 2-12: Tests — Impact (IEC 61300-2-12:2009)
EN 61300-2-22, Fibre optic interconnecting devices and passive components — Basic test and measurement
procedures — Part 2-22: Tests — Change of temperature (IEC 61300-2-22)
EN 61300-2-33, Fibre optic interconnecting devices and passive components — Basic test and measurement
procedures — Part 2-33: Tests — Assembly and disassembly of fibre optic mechanical splices, fibre
management systems and closures (IEC 61300-2-33)
6

---------------------- Page: 8 ----------------------

SIST EN 50411-3-5:2016
EN 50411-3-5:2015
EN 61300-3-1, Fibre optic interconnecting devices and passive components — Basic test and measurement
procedures — Part 3-1: Examinations and measurements — Visual examination (IEC 61300-3-1)
EN 61300-3-3:2009, Fibre optic interconnecting devices and passive components — Basic test and
measurement procedures — Part 3-3: Examinations and measurements — Active monitoring of changes in
attenuation and return loss (IEC 61300-3-3:2009)
EN 61300-3-28, Fibre optic interconnecting devices and passive components — Basic test and measurement
procedures — Part 3-28: Examinations and measurements — Transient loss (IEC 61300-3-28)
3 Terms, definitions and abbreviations
For the purposes of this document, the following terms and definitions apply.
3.1 Terms and definitions
3.1.1
fibre management system
system to control fibre routing from the incoming to the out-going fibres, containing one or more splice
cassettes and additional functional elements, and which provides a means for routing, storing and protecting
of fibre splices, connectors or other passive optical devices in a predetermined order, from one cable sheath
opening to another
3.1.2
microduct system
system that provides for routing air blown fibres or microduct fibre units, between hollow conduits
(microducts), and interconnects the microducts by use of pneumatic connectors, tube welding, crimp
connectors or push on connectors
3.2 Abbreviations
For the purposes of this document, the following abbreviations apply.
MD Microduct
FMS Fibre Management System
FPFT Factory Polished Field Terminated
4 Descrip
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.