Glass in building - Thermally toughened soda lime silicate channel shaped safety glass - Part 2: Evaluation of conformity/Product standard

This part of EN 15683 covers the evaluation of conformity and the factory production control of thermally toughened soda lime silicate channel shaped safety glass for use in buildings.
This also includes requirements subject to regulation.

Glas im Bauwesen - Thermisch vorgespanntes Kalknatron-Profilbau-Sicherheitsglas - Teil 2: Konformitätsbewertung/Produktnorm

Dieser Teil von EN 15683 behandelt die Konformitätsbewertung und die werkseigene Produktionskontrolle von thermisch vorgespanntem Kalknatron-Profilbau-Sicherheitsglas zur Anwendung im Bauwesen.
Eingeschlossen sind auch Anforderungen, die Gegenstand von Vorschriften sind.

Verre dans la construction - Verre de silicate sodo-calcique profilé de sécurité trempé thermiquement - Partie 2 : Evaluation de la conformité/Norme de produit

La présente partie de l’EN 15683 document spécifie des exigences relatives à l'évaluation de la conformité et au contrôle de la production en usine du verre de silicate sodo-calcique profilé de sécurité trempé thermiquement, utilisé dans la construction.
Elle comporte également des exigences soumises à réglementation.

Steklo v gradbeništvu - Toplotno kaljeno natrij-kalcijevo silikatno utorjeno varnostno steklo - 2. del: Ovrednotenje skladnosti/standard za izdelek

General Information

Status
Not Published
Public Enquiry End Date
29-Sep-2012
Current Stage
98 - Abandoned project (Adopted Project)
Start Date
16-Sep-2013
Due Date
21-Sep-2013
Completion Date
16-Sep-2013

Buy Standard

Draft
prEN 15683-2:2012
English language
34 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

SLOVENSKI STANDARD
oSIST prEN 15683-2:2012
01-september-2012
Steklo v gradbeništvu - Toplotno kaljeno natrij-kalcijevo silikatno utorjeno
varnostno steklo - 2. del: Ovrednotenje skladnosti/standard za izdelek
Glass in building - Thermally toughened soda lime silicate channel shaped safety glass -
Part 2: Evaluation of conformity/Product standard
Glas im Bauwesen - Thermisch vorgespanntes Kalknatron-Profilbau-Sicherheitsglas -
Teil 2: Konformitätsbewertung/Produktnorm
Verre dans la construction - Verre de silicate sodo-calcique profilé de sécurité trempé
thermiquement - Partie 2 : Evaluation de la conformité/Norme de produit
Ta slovenski standard je istoveten z: prEN 15683-2
ICS:
81.040.20 Steklo v gradbeništvu Glass in building
oSIST prEN 15683-2:2012 en,fr,de
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------
oSIST prEN 15683-2:2012

---------------------- Page: 2 ----------------------
oSIST prEN 15683-2:2012


EUROPEAN STANDARD
DRAFT
prEN 15683-2
NORME EUROPÉENNE

EUROPÄISCHE NORM

June 2012
ICS 81.040.20
English Version
Glass in building - Thermally toughened soda lime silicate
channel shaped safety glass - Part 2: Evaluation of
conformity/Product standard
Verre dans la construction - Verre de silicate sodo-calcique Glas im Bauwesen - Thermisch vorgespanntes Kalknatron-
profilé de sécurité trempé thermiquement - Partie 2 :
Profilbau-Sicherheitsglas - Teil 2:
Evaluation de la conformité/Norme de produit Konformitätsbewertung/Produktnorm
This draft European Standard is submitted to CEN members for enquiry. It has been drawn up by the Technical Committee CEN/TC 129.

If this draft becomes a European Standard, CEN members are bound to comply with the CEN/CENELEC Internal Regulations which
stipulate the conditions for giving this European Standard the status of a national standard without any alteration.

This draft European Standard was established by CEN in three official versions (English, French, German). A version in any other language
made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management
Centre has the same status as the official versions.

CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia,
Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland,
Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and United Kingdom.

Recipients of this draft are invited to submit, with their comments, notification of any relevant patent rights of which they are aware and to
provide supporting documentation.

Warning : This document is not a European Standard. It is distributed for review and comments. It is subject to change without notice and
shall not be referred to as a European Standard.


EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION

EUROPÄISCHES KOMITEE FÜR NORMUNG

Management Centre: Avenue Marnix 17, B-1000 Brussels
© 2012 CEN All rights of exploitation in any form and by any means reserved Ref. No. prEN 15683-2:2012: E
worldwide for CEN national Members.

---------------------- Page: 3 ----------------------
oSIST prEN 15683-2:2012
prEN 15683-2:2012 (E)
Contents Page
Foreword .4
1 Scope .5
2 Normative references .5
3 Terms and definitions .6
4 Requirements .6
4.1 Product description .6
4.2 Conformity with the definition of thermally toughened soda lime silicate channel shaped
safety glass .7
4.3 Determination of the performances of characteristics .7
4.3.1 Characteristics of thermally toughened soda lime silicate channel shaped safety glass .7
4.3.2 Determination of characteristics of thermally toughened soda lime silicate channel
shaped safety glass products .8
4.4 Durability . 10
4.5 Dangerous substances . 11
5 Evaluation of conformity . 11
5.1 General . 11
5.2 Initial type testing of the product (see 5.1, 2)) . 11
5.2.1 General . 11
5.2.2 Initial type testing of thermally toughened soda lime silicate channel shaped safety glass . 13
5.2.3 Initial type testing of characteristic’s performances . 15
5.3 Factory production control and inspection of samples in accordance with a prescribed
test plan (see 5.1, 1) a) and b)) . 15
5.4 Initial inspection of factory and of factory production control (see 5.1, 1) d)) . 15
5.5 Continuous surveillance and assessment of the factory production control (see 5.1, 1) c)) . 16
6 Marking and labelling . 17
6.1 General . 17
6.2 Product marking . 17
6.3 Product characteristics . 17
6.4 "Characteristic/performance identification paper" . 17
Annex A (normative) Factory production control . 18
A.1 Factory Production Control Requirements . 18
A.1.1 General . 18
A.1.2 Organisation . 18
A.1.3 Control system . 18
A.2 Marking . 19
A.3 Inspection and testing tables of thermally toughened soda lime silicate channel shaped
safety glass production . 19
A.3.1 Information to the Table A.1 . 19
A.3.2 Production control . 20
A.3.3 Product control . 20
A.3.4 Use of proxy testing . 20
Annex B (informative) Tests for factory production control – Fragmentation test . 24
B.1 Requirements . 24
B.2 Test method . 24
2

---------------------- Page: 4 ----------------------
oSIST prEN 15683-2:2012
prEN 15683-2:2012 (E)
Annex C (informative) Provisions for voluntary involvement of third party(ies) . 25
C.1 General . 25
C.2 Voluntary tasks for third parties . 25
C.3 Marking and labelling . 25
Annex ZA (normative) Clauses of this European Standard addressing the provisions of
EU Construction Products Directive . 26
ZA.1 Scope and relevant characteristics . 26
ZA.2 Procedure(s) for the attestation of conformity of thermally toughened soda lime silicate
channel shaped safety glass products . 28
ZA.2.1 System(s) of attestation of conformity. 28
ZA.2.2 EC Certificate and Declaration of conformity . 30
ZA.3 CE marking and labelling . 32
Bibliography . 34

3

---------------------- Page: 5 ----------------------
oSIST prEN 15683-2:2012
prEN 15683-2:2012 (E)
Foreword
This document (prEN 15683-2:2012) has been prepared by Technical Committee CEN/TC 129 “Glass in
building”, the secretariat of which is held by NBN.
This document is currently submitted to the CEN Enquiry.
This document has been prepared under a mandate given to CEN by the European Commission and the
European Free Trade Association, and supports essential requirements of EU Directive(s).
For relationship with EU Directive 89/106/EEC, see informative Annex ZA, which is an integral part of this
document.
EN 15683, Glass in building — Thermally toughened soda lime silicate channel shaped safety glass, consists
of the following parts:
 Part 1: Definition and description;
 Part 2: Evaluation of conformity/Product standard.
This European Standard contains other aspects of importance of trade.
4

---------------------- Page: 6 ----------------------
oSIST prEN 15683-2:2012
prEN 15683-2:2012 (E)
1 Scope
This part of EN 15683 covers the evaluation of conformity and the factory production control of thermally
toughened soda lime silicate channel shaped safety glass for use in buildings.
This also includes requirements subject to regulation.
2 Normative references
The following documents, in whole or in part, are normatively referenced in this document and are
indispensable for its application. For dated references, only the edition cited applies. For undated references,
the latest edition of the referenced document (including any amendments) applies.
EN 356, Glass in building — Security glazing — Testing and classification of resistance against manual attack
EN 410, Glass in building —Determination of luminous and solar characteristics of glazing
EN 673, Glass in building — Determination of thermal transmittance (U value) — Calculation method
EN 572-1, Glass in building — Basic soda lime silicate glass products — Part 1: Definitions and general
physical and mechanical properties
EN 572-7, Glass in Building — Basic soda lime silicate glass products — Part 7: Wired or unwired channel
shaped glass
EN 1063, Glass in building — Security glazing — Testing and classification of resistance against bullet attack
EN 1096-1, Glass in building — Coated glass — Part 1: Definitions and classification
EN 1096-2, Glass in building — Coated glass — Part 2: Requirements and test methods for class A, B and S
coatings
EN 12600, Glass in building — Pendulum test — Impact test method and classification for flat glass
EN 12758, Glass in building — Glazing and airborne sound insulation — Product descriptions and
determination of properties
EN 12898, Glass in building — Determination of the emissivity
prEN 13474 (all parts), Glass in building — Design of glass panes
EN 13501-1, Fire classification of construction products and building elements — Part 1: Classification using
data from reaction to fire tests
EN 13501-2, Fire classification of construction products and building elements — Part 2: Classification using
data from fire resistance tests, excluding ventilation services
EN 13501-5, Fire classification of construction products and building elements — Part 5: Classification using
data from external fire exposure to roof tests
EN 13541, Glass in building — Security glazing — Testing and classification of resistance against explosion
pressure
prEN 15683-1:2012, Glass in building — Thermally toughened soda lime silicate channel shaped safety
glass — Part 1: Definition and description
ISO 9358, Optics and optical instruments — Veiling glare of image forming systems — Definitions and
methods of measurement
5

---------------------- Page: 7 ----------------------
oSIST prEN 15683-2:2012
prEN 15683-2:2012 (E)
3 Terms and definitions
For the purpose of this document, the terms and definitions given in prEN 15683-1:2012 and the following
apply.
3.1
initial type testing
determination of the performance of a product (characteristic, durability), on the basis of either actual tests or
other procedures (such as conventional, standardised, tabulated or general accepted values, standardised or
recognised calculation methods, test reports when made available), in accordance with this document that
demonstrates compliance with this document
[SOURCE: EN 572-9:2004, 3.1]
3.2
test report
document that covers the results of tests undertaken on a representative sample of the product from
production or on a prototype design of the product
[SOURCE: EN 572-9:2004, 3.2]
3.3
product description
document that details the relevant parameters, e.g. process conditions, structure, etc., for defining a product
that complies with the standard. It includes specific reference(s) to characteristics that are modified by the
production process
[SOURCE: EN 572-9:2004, 3.3]
3.4
significant change
variation in performance beyond the permitted tolerance for the characteristic
[SOURCE: EN 572-9:2004, 3.4]
3.5
plank
a length of channel shaped glass.
4 Requirements
4.1 Product description
For conformity purposes, the thermally toughened soda lime silicate channel shaped glass manufacturer is
responsible for the preparation and maintenance of the product description. This description shall describe the
product and/or product families.
Disclosure of the product description shall be at the discretion of the thermally toughened glass manufacturer
or his agent except in the case of regulatory requirements.
The description shall contain at least a normative part. The description may also contain an informative part,
when the manufacturer foresees further development of the product.
6

---------------------- Page: 8 ----------------------
oSIST prEN 15683-2:2012
prEN 15683-2:2012 (E)
The normative part of the description shall contain the following minimum information:
 a reference to prEN 15683-1 and prEN 15683-2 and all other standards with which the manufacturer
claims compliance;
 the radiometric properties and durability of coated glass, i.e. coated glass that conforms with EN 1096-1
and EN 1096-2, when those properties are changed, intentionally or unintentionally, by the thermal
toughening process.
The definition of product families shall be consistent with the normative part of the product description.
The substitution of materials shall maintain the conformity with the product description. The substituting
material can be added to the product family and also the product description when compliance has been
demonstrated.
4.2 Conformity with the definition of thermally toughened soda lime silicate channel
shaped safety glass
Products shall conform to the definition and fulfil the requirements of thermally toughened soda lime silicate
channel shaped safety glass as defined in prEN 15683-1.
4.3 Determination of the performances of characteristics
4.3.1 Characteristics of thermally toughened soda lime silicate channel shaped safety glass
4.3.1.1 General
The characteristics of thermally toughened soda lime silicate channel shaped safety glass are those of the
glass substrate (see 4.3.1.2).
4.3.1.2 Characteristics of channel shaped glass used for thermally toughened soda lime silicate
channel shaped safety glass
Planks shall be made of unwired channel shaped glass products according to EN 572-1 and EN 572-7. The
panes may be coated according to EN 1096-1 and EN 1096-2, and/or enamelled according to prEN 15683-1.
For the characteristics listed in Table 1, for thermally toughened soda lime silicate channel shaped safety
glass, generally accepted values or calculated values shall be used.
Since the majority of the characteristics of Table 1 are not changed significantly by the thermal toughening
process they shall be used for thermally toughened soda lime silicate channel shaped safety glass. The
exceptions shall be the characteristic bending strength f and the resistance against sudden temperature
g,k
changes and temperature differentials.
7

---------------------- Page: 9 ----------------------
oSIST prEN 15683-2:2012
prEN 15683-2:2012 (E)
Table 1 — Information on the characteristics of basic channel shaped glass, according to EN 572-1,
used for the production of thermally toughened soda lime silicate channel shaped safety glass
Characteristic Symbol Unit
- Density ρ kg/m³
- Hardness (knoop hardness in accordance with ISO 9358) GPa
HK
0,1/20
- Young's modulus E Pa
- Poisson's ratio Dimensionless
µ
- Characteristic bending strength Pa
f
g,k
- Resistance against sudden temperature changes and temperature differentials K
- Specific heat capacity
c
J/(kg.K)
- Coefficient of linear expansion -1
α K
- Thermal conductivity (for U-value)
λ W/(m.K)
- Mean refractive index to visible radiation
Dimensionless
n
- Emissivity
Dimensionless
ε
- Light transmittance
Dimensionless
τ
v
- Solar direct transmittance
Dimensionless
τ
e
- Total energy transmittance
Dimensionless
g

If some coatings, i.e. coated glass conforming with EN 1096 series, when thermally toughened change their
radiometric properties the manufacturer shall refer to the following for the determination of the appropriate
characteristics etc.:
 4.3.2.12 for the emissivity;
 4.3.2.13 for the light transmittance and reflectance;
 4.3.2.14 for the solar energy transmittance;
 EN 1096-2 for the durability of A, B and S coatings;
4.3.2 Determination of characteristics of thermally toughened soda lime silicate channel shaped
safety glass products
4.3.2.1 General
If the thermally toughened glass manufacturer wishes to claim that any performance characteristic is
independent of the production equipment used then the factory production control system shall be in
accordance with this document including his specific process control conditions
4.3.2.2 Safety in the case of fire - Resistance to fire
Fire resistance shall be determined and classified in accordance with EN 13501-2.
NOTE EN 357 may be used as a classification reference specific to fire resistant glazed elements.
8

---------------------- Page: 10 ----------------------
oSIST prEN 15683-2:2012
prEN 15683-2:2012 (E)
4.3.2.3 Safety in the case of fire - Reaction to fire
Reaction to fire shall be determined and classified in accordance with EN 13501-1.
Thermally toughened soda lime silicate channel shaped safety glass products are products/materials that do
not require to be tested for reaction to fire (e.g. Products/materials of Classes A1 according to Commission
Decision 96/603/EC, as amended 2000/605/EC).
4.3.2.4 Safety in the case of fire - External fire behaviour
Where the manufacturer wishes to declare external fire performance (e.g. when subject to regulatory
requirements), the product shall be tested and classified in accordance with EN 13501-5.
4.3.2.5 Safety in use - Bullet resistance: shatter properties and resistance to attack
Bullet resistance shall be determined and classified in accordance with EN 1063.
NOTE Thermally toughened soda lime silicate channel shaped glass will usually not be classified as bullet resistant.
4.3.2.6 Safety in use - Explosion resistance: impact behaviour and resistance to impact
Explosion resistance shall be determined and classified in accordance with EN 13541.
NOTE Thermally toughened soda lime silicate channel shaped glass will usually not be classified as explosion
resistant.
4.3.2.7 Safety in use - Burglar resistance: shatter properties and resistance to attack
Burglar resistance shall be determined and classified in accordance with EN 356.
NOTE Thermally toughened soda lime silicate channel shaped glass will usually not be classified as burglar resistant
4.3.2.8 Safety in use - Pendulum body impact resistance: shatter properties (safe breakability) and
resistance to impact
Pendulum body impact resistance shall be determined and classified in accordance with EN 12600.
NOTE 1 Thermally toughened soda lime silicate channel shaped glass cannot be classified for pendulum body impact
resistance as the test method only applies to flat glass.
NOTE 2 A system incorporating thermally toughened soda lime silicate channel shaped glass may be tested and
impact performance determined.
4.3.2.9 Safety in use - Mechanical resistance: Resistance against sudden temperature changes and
temperature differentials
The resistance against sudden temperature changes and temperature differentials is a generally accepted
value that is given in prEN 15683-1 and shall be ensured by compliance with this document.
4.3.2.10 Safety in use - Mechanical resistance: Resistance against wind, snow, permanent load
and/or imposed loads of the glass unit
The mechanical strength of thermally toughened soda lime silicate channel shaped safety glass is a
characteristic value that is given in prEN 15683-1 and shall be ensured by compliance with this document.
As long as on the concerned construction or building site no part of prEN 13474 is applicable for the design
then the current method of determining mechanical resistance in the country of destination shall be applied.
9

---------------------- Page: 11 ----------------------
oSIST prEN 15683-2:2012
prEN 15683-2:2012 (E)
The manufactured or supplied type, i.e. thickness, width and flange height, and length (H) of thermally
toughened soda lime silicate channel shaped safety glass shall conform to the ordered type and length (H).
4.3.2.11 Protection against noise - Direct airborne sound reduction
The sound reduction indexes shall be determined in accordance with EN 12758. However, the information
supplied with the incoming glass may be used as the thermal toughening process does not alter the values.
4.3.2.12 Energy conservation and heat retention - Thermal properties
The thermal transmittance value (U-value) shall be determined by calculation in accordance with EN 673 with
the following:
 emissivity ε: the declared value of the glass manufacturer. If the information is not available, the
emissivity shall be determined in accordance with EN 12898;
 nominal thickness of the glass panes.
Subject to 5.2.1, the information supplied about the thermal properties of the incoming glass may be used if
the thermal toughening process does not alter the values.
4.3.2.13 Energy conservation and heat retention - Radiation properties: Light transmittance and
reflectance
The light transmittance and reflectance shall be determined in accordance with EN 410.
Subject to 5.2.1, the information supplied about the radiation properties of the incoming glass may be used if
the thermal toughening process does not alter the values.
4.3.2.14 Energy conservation and heat retention - Radiation properties: Solar energy characteristics
The solar energy transmittance and reflectance shall be determined in accordance with EN 410.
Subject to 5.2.1, the information supplied about the radiation properties of the incoming glass can be used if
the thermal toughening process does not alter the values.
4.4 Durability
When products conform to the definition of thermally toughened soda lime silicate channel shaped safety
glass as 4.2 then the characteristics’ performances in 4.3.2 are ensured during an economically reasonable
working life.
The durability of glass products including their characteristics, shall be ensured by the following:
 compliance with this document;
 compliance with instructions from the glass product manufacturer or supplier.
The manufacturer shall supply specific installation instructions or make reference to appropriate technical
specifications.
NOTE The durability of glass products depends on
 building and construction movements due to various actions,
 building and construction vibrations due to various actions,
10

---------------------- Page: 12 ----------------------
oSIST prEN 15683-2:2012
prEN 15683-2:2012 (E)
 deflection and racking of the glass support due to various actions,
 glass support design (e.g. drainage of infiltrated water in the rebate, prevention of direct contact between glass
support members and glass),
 accuracy of glass support and glass support member dimensions,
 quality of installation of the glass support into or onto the buildings or constructions,
 glass support expansion due to adsorbed moisture from the air or other sources,
 the quality of installation of the glass product into or onto its support.
4.5 Dangerous substances
Materials used in products shall not release any dangerous substances in excess of the maximum permitted
levels specified in a relevant European Standard for the material or permitted in the national regulations of the
Member State of destination.
5 Evaluation of conformity
5.1 General
The evaluation of conformity shall be based on:
1) Factory production control;
This shall include the following:
a) inspection of samples taken at the factory in accordance with a prescribed test plan;
b) initial inspection of the factory and of factory production control;
c) continuous surveillance and assessment of the factory production control.
2) Initial type testing of the product;
NOTE There may be a need to involve a third party, with 1) b), 1) c), and/or 2), for the purpose of regulatory marking (see
Annex ZA).
5.2 Initial type testing of the product (see 5.1, 2))
5.2.1 General
All the product’s characteristics shall be initial type tested to verify they are in conformity with the requirements
of this document. In addition, instead of performing any actual testing, initial type testing may make use of
 generally accepted and/or conventional and/or standardised values, in Clause 2 referenced standards, or
in publications that are referred to in these standards,
 standardised calculation methods and recognised calculation methods in Clause 2 referenced standards,
or in publications that are referred to in these standards,
 test report(s) on the basis of 5.2.1.2 when made available except for the characteristics listed in 5.2.2,
11

---------------------- Page: 13 ----------------------
oSIST prEN 15683-2:2012
prEN 15683-2:2012 (E)
 where components are used whose characteristics have already been determined, by the component
manufacturer, on the basis of conformity with other product standards, thes
...