SIST EN 15698-1:2009
(Main)District heating pipes - Preinsulated bonded twin pipe systems for directly buried hot water networks - Part 1: Twin pipe assembly of steel service pipe, polyurethane thermal insulation and outer casing of polyethylene
District heating pipes - Preinsulated bonded twin pipe systems for directly buried hot water networks - Part 1: Twin pipe assembly of steel service pipe, polyurethane thermal insulation and outer casing of polyethylene
This European Standard for District Heating Twin Pipes, specifies requirements and test methods for straight lengths of prefabricated thermally insulated pipe-in-pipe assemblies for directly buried hot water networks, comprising two steel service pipes from DN 15 to DN 250, rigid polyurethane foam insulation and one outer casing of polyethylene. The pipe assembly may also include the following additional elements: Measuring wires, spacers and diffusion barriers. This standard applies only to insulated twin pipe assemblies, for continuous operation with hot water at various temperatures up to 120 °C and occasionally with a peak temperature up to 140 °C and various internal pressures up to PN 16. The estimation of expected thermal life with continuous operation at various temperatures is outlined in annex B of EN 253.
Fernwärmerohre - Werkmäßig gedämmte Verbundmanteldoppelrohre für direkt erdverlegte Fernwärmenetze - Teil 1: Verbund-Doppelrohrsystem bestehend aus zwei Stahl-Mediumrohren, Polyurethan-Wärmedämmung und einem Außenmantel aus Polyethylen
In dieser Europäischen Norm für Fernwärme-Doppelrohrsysteme sind Anforderungen und Prüfverfahren für
gerade Abschnitte von werkmäßig gedämmten Rohr-in-Rohr-Systemen für direkt erdverlegte Fernwärmenetze
festgelegt, die aus zwei Stahl-Mediumrohren von DN 15 bis DN 250 mit einer Wärmedämmung aus
Polyurethan-Hartschaumstoff und einer Ummantelung aus Polyethylen mit kreisförmigem Querschnitt
bestehen. Das Verbund-Rohrsystem darf darüber hinaus folgende Bauteile umfassen: Messdrähte,
Abstandhalter und Diffusionsbarrieren.
Diese Norm gilt nur für wärmegedämmte Doppelrohrsysteme für den Dauerbetrieb mit Warmwasser bei unterschiedlichen
Betriebstemperaturen von bis zu 120 °C und gelegentlich auftretenden Spitzentemperaturen von
bis zu 140 °C.
Die Abschätzung der erwarteten thermischen Lebensdauer bei Dauerbetrieb mit unterschiedlichen Betriebstemperaturen
wird in EN 253, Anhang B erläutert.
Tuyaux de chauffage urbain - Systèmes bloqués de bitubes préisolés pour les réseaux d'eau chaude enterrés directement - Partie 1: Assemblage de bitubes pour tube de service en acier, isolation thermique en polyuréthane et tube de protection en polyéthylène
La présente Norme européenne pour les bitubes de chauffage urbain définit les prescriptions et les méthodes
d’essais applicables aux longueurs droites de systèmes préfabriqués de tubes isolés thermiquement pour
réseaux d’eau chaude enterrés directement comprenant deux tubes de service en acier de DN 15 à DN 250,
une isolation en mousse rigide de polyuréthane et un tube de protection en polyéthylène. Le tube préisolé
peut également comprendre les éléments supplémentaires suivants : les câbles de mesure, les entretoises et
les barrières anti diffusion.
La présente Norme s’applique uniquement aux assemblages de bitubes isolés utilisés pour l’eau chaude à
différentes températures pouvant aller en service continu jusqu'à 120 °C et, parfois, à une température de
pointe pouvant atteindre 140 °C.
L’estimation de la durée de vie thermique escomptée de systèmes opérant à différentes températures en
service continu est donnée à l’Annexe B de l’EN 253.
Cevi za daljinsko ogrevanje - Izolirani vezani dvocevni sistemi za podzemeljska toplovodna omrežja - 1. del: Dvocevni sestav iz jeklene cevi, poliuretanske toplotne izolacije in zunanjega polietilenskega plašča
General Information
Relations
Standards Content (Sample)
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.LXUHWDQVNHFernwärmerohre - Werkmäßig gedämmte Verbundmanteldoppelrohre für direkt erdverlegte Fernwärmenetze - Teil 1: Verbund-Doppelrohrsystem bestehend aus zwei Stahl-Mediumrohren, Polyurethan-Wärmedämmung und einem Außenmantel aus PolyethylenTuyaux de chauffage urbain - Systèmes bloqués de bitubes préisolés pour les réseaux d'eau chaude enterrés directement - Partie 1: Assemblage de bitubes pour tube de service en acier, isolation thermique en polyuréthane et tube de protection en polyéthylèneDistrict heating pipes - Preinsulated bonded twin pipe systems for directly buried hot water networks - Part 1: Twin pipe assembly of steel service pipe, polyurethane thermal insulation and outer casing of polyethylene91.140.10Sistemi centralnega ogrevanjaCentral heating systems23.040.10Železne in jeklene ceviIron and steel pipesICS:Ta slovenski standard je istoveten z:EN 15698-1:2009SIST EN 15698-1:2009en,fr01-april-2009SIST EN 15698-1:2009SLOVENSKI
STANDARD
SIST EN 15698-1:2009
EUROPEAN STANDARDNORME EUROPÉENNEEUROPÄISCHE NORMEN 15698-1January 2009ICS 23.040.10 English VersionDistrict heating pipes - Preinsulated bonded twin pipe systemsfor directly buried hot water networks - Part 1: Twin pipeassembly of steel service pipe, polyurethane thermal insulationand outer casing of polyethyleneTuyaux de chauffage urbain - Systèmes bloqués de bitubespréisolés pour les réseaux d'eau chaude enterrésdirectement - Partie 1: Assemblage de bitubes pour tube deservice en acier, isolation thermique en polyuréthane ettube de protection en polyéthylèneFernwärmerohre - Werkmäßig gedämmteVerbundmanteldoppelrohre für direkt erdverlegteFernwärmenetze - Teil 1: Verbund-Doppelrohrsystembestehend aus zwei Stahl-Mediumrohren, Polyurethan-Wärmedämmung und einem Außenmantel aus PolyethylenThis European Standard was approved by CEN on 5 December 2008.CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this EuropeanStandard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such nationalstandards may be obtained on application to the CEN Management Centre or to any CEN member.This European Standard exists in three official versions (English, French, German). A version in any other language made by translationunder the responsibility of a CEN member into its own language and notified to the CEN Management Centre has the same status as theofficial versions.CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland,France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal,Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom.EUROPEAN COMMITTEE FOR STANDARDIZATIONCOMITÉ EUROPÉEN DE NORMALISATIONEUROPÄISCHES KOMITEE FÜR NORMUNGManagement Centre: rue de Stassart, 36
B-1050 Brussels© 2009 CENAll rights of exploitation in any form and by any means reservedworldwide for CEN national Members.Ref. No. EN 15698-1:2009: ESIST EN 15698-1:2009
EN 15698-1:2009 (E) 2 Contents page Foreword . 3 Introduction . 4 1 Scope . 5 2 Normative references . 5 3 Terms and definitions . 5 4 Requirements . 5 4.1 General . 5 4.2 Steel service pipe. 5 4.3 Material, casing properties and dimensions . 6 4.4 Polyurethane rigid foam insulation (PUR) . 6 4.5 Pipe assembly . 6 4.5.1 End alignment of forward and return service pipes. 6 4.5.2 Distance between forward and return service pipes . 6 4.5.3 Twisting of service pipes . 7 4.5.4 Centre line deviation . 8 4.5.5 Pipe ends . 9 4.5.6 Axial shear strength . 9 4.5.7 Expected thermal life and long term temperature resistance . 9 4.5.8 Thermal conductivity in unaged condition . 9 4.5.9 Impact resistance. 9 4.5.10 Long term creep resistance and modulus . 9 4.5.11 Surface conditions at delivery . 9 4.5.12 Measuring wires for surveillance systems . 9 5 Test methods . 9 5.1 General . 9 5.2 Test specimens . 9 5.3 Casing . 10 5.4 Polyurethane rigid foam insulation (PUR) . 10 5.5 Pipe assembly . 10 5.5.1 Axial shear strength . 10 5.5.2 Expected thermal life and long term temperature resistance . 13 5.5.3 Thermal conductivity in unaged condition . 13 5.5.4 Thermal transmittance . 13 5.5.5 Impact resistance. 13 5.5.6 Creep behaviour at 140 °°°°C . 13 6 Marking . 13 Annex A (informative)
Guidelines for inspection and testing. 14 Annex B (informative)
Calculation of thermal transmittance. 15 Annex C (informative)
Waste treatment and recycling . 17 Bibliography . 18
SIST EN 15698-1:2009
EN 15698-1:2009 (E) 3 Foreword This document (EN 15698-1:2009) has been prepared by Technical Committee CEN/TC 107 “Prefabricated district heating pipe systems”, the secretariat of which is held by DS. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by July 2009, and conflicting national standards shall be withdrawn at the latest by July 2009. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN [and/or CENELEC] shall not be held responsible for identifying any or all such patent rights. According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom. SIST EN 15698-1:2009
EN 15698-1:2009 (E) 4 Introduction This specification is part of the standards for bonded systems using polyurethane foam thermal insulation applied to bond to two steel service pipes and a polyethylene casing. This standard has been elaborated as a complement to the standards for bonded systems using polyurethane foam thermal insulation applied to bond to one steel service pipe and a polyethylene casing. These standards are: EN 253, District heating pipes – Preinsulated bonded pipe systems for directly buried hot water networks – Pipe assembly of steel service pipe, polyurethane thermal insulation and outer casing of polyethylene; EN 448, District heating pipes – Preinsulated bonded pipe systems for directly buried hot water networks – Fitting assemblies of steel service pipes, polyurethane thermal insulation and outer casing of polyethylene; EN 488, District heating pipes – Preinsulated bonded pipe systems for directly buried hot water networks – Steel valve assembly for steel service pipes, polyurethane thermal insulation and outer casing of polyethylene; EN 489, District heating pipes – Preinsulated bonded pipe systems for directly buried hot water networks – Joint assembly for steel service pipes, polyurethane thermal insulation and outer casing of polyethylene; EN 13941, Design and installation of preinsulated bonded pipe systems for district heating; EN 14419, District heating pipes – Preinsulated bonded pipe systems for directly buried hot water networks – Surveillance systems.
Waste management and recycling of materials is dealt with in Annex C. SIST EN 15698-1:2009
EN 15698-1:2009 (E) 5 1 Scope This European Standard for District Heating Twin Pipes, specifies requirements and test methods for straight lengths of prefabricated thermally insulated pipe-in-pipe assemblies for directly buried hot water networks, comprising two steel service pipes from DN 15 to DN 250, rigid polyurethane foam insulation and one cylindrical outer casing of polyethylene. The pipe assembly may also include the following additional elements: Measuring wires, spacers and di
...
Questions, Comments and Discussion