oSIST prEN 15100-1:2005
(Main)Thermal insulating products for buildings - In-situ formed urea-formaldehyde foam (UF) products - Part 1: Specification for the foam system before installation
Thermal insulating products for buildings - In-situ formed urea-formaldehyde foam (UF) products - Part 1: Specification for the foam system before installation
This document specifies requirements for in-situ formed urea formaldehyde foam (UF) products when installed in external walls, internal walls, partitions, floors and roofs. Products covered by this standard may also be used for acoustic applications.
This document is a specification for the rigid foam dispensing system before installation.
This document describes the product characteristics and includes procedures for testing, marking and labelling and the rules for evaluation of conformity.
This document does not specify the required level of all properties that should be achieved by a product to demonstrate fitness for purpose in a particular application. The required levels are to be found in regulations or non-conflicting standards.
UF products with a declared thermal conductivity at 10 °C (mean temperature) greater than 0,050 W/(mK) are not covered by this document.
This document does not cover factory made products utilising urea formaldehyde foam intended to be used for the insulation of buildings or for the insulation of building equipment and industrial installations.
This document does not specify all the requirements for the raw materials or the performance requirements for loadbearing applications.
Wärmedämmstoffe für Gebäude - An der Verwendungsstelle hergestellte Wärmedämmung aus Harnstoff-Formaldehydharz-Schaum (UF) - Teil 1: Spezifikation für das Schaumsystem vor dem Einbau
Dieses Dokument legt die Anforderungen für an der Verwendungsstelle hergestellte Produkte aus Harnstoff-Formaldehydharz-Schaum (UF) fest, die in Außenwände, Innenwände, Trennwände, Böden und Dächer eingebaut werden. Produkte nach dieser Norm können auch für Anwendungsgebiete der akustischen Schalldämmung verwendet werden.
Dieses Dokument ist eine Spezifikation für das Schaumsystem vor dem Einbau.
Dieses Dokument beschreibt die Produkteigenschaften und enthält Verfahren für die Prüfung, Kennzeichnung und Etikettierung sowie die Regeln der Konformitätsbewertung.
Diese Norm legt keine Leistungsstufen für alle Eigenschaften fest, die ein Produkt erreichen sollte, um für einen bestimmten Anwendungsfall tauglich zu sein. Für bestimmte Anwendungen benötigte Stufen können Regelwerken oder nicht entgegenstehenden Normen entnommen werden.
UF-Produkte mit einem Nennwert der Wärmeleitfähigkeit bei 10 °C (Mitteltemperatur) von mehr als
0,050 W(m × K) sind nicht Gegenstand dieses Dokuments.
Dieses Dokument gilt nicht für werkmäßig hergestellte Produkte aus Harnstoff-Formaldehydharz-Schaum für die Wärmedämmung von Gebäuden oder die Wärmedämmung für die Haustechnik und betriebstechnische Anlagen.
Dieses Dokument legt nicht alle Anforderungen für die Rohstoffe oder die Leistungsanforderungen für lasttragende Anwendungsbereiche fest.
Produits isolants thermiques pour le bâtiment - Isolation formée en place a base de mousse de formaldéhyde (UF) - Partie 1: Spécification du systeme de mouse avant la mise en place
Toplotnoizolacijski proizvodi za stavbe – Na mestu vgradnje pripravljeni sečninsko formaldehidni penasti (UF) proizvodi – 1. del: Specifikacije penastega sistema pred vgradnjo
General Information
Standards Content (Sample)
SLOVENSKI STANDARD
01-januar-2005
7RSORWQRL]RODFLMVNLSURL]YRGL]DVWDYEH±1DPHVWXYJUDGQMHSULSUDYOMHQLVHþQLQVNR
IRUPDOGHKLGQLSHQDVWL8)SURL]YRGL±GHO6SHFLILNDFLMHSHQDVWHJDVLVWHPDSUHG
YJUDGQMR
Thermal insulating products for buildings - In-situ formed urea-formaldehyde foam (UF)
products - Part 1: Specification for the foam system before installation
Wärmedämmstoffe für Gebäude - An der Verwendungsstelle hergestellte
Wärmedämmung aus Harnstoff-Formaldehydharz-Schaum (UF) - Teil 1: Spezifikation für
das Schaumsystem vor dem Einbau
Produits isolants thermiques pour le bâtiment - Isolation formée en place a base de
mousse de formaldéhyde (UF) - Partie 1: Spécification du systeme de mouse avant la
mise en place
Ta slovenski standard je istoveten z: prEN 15100-1
ICS:
91.100.60 0DWHULDOL]DWRSORWQRLQ Thermal and sound insulating
]YRþQRL]RODFLMR materials
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
EUROPEAN STANDARD
DRAFT
NORME EUROPÉENNE
EUROPÄISCHE NORM
November 2004
ICS
English version
Thermal insulating products for buildings - In-situ formed urea-
formaldehyde foam (UF) products - Part 1: Specification for the
foam system before installation
Produits isolants thermiques pour le bâtiment - Isolation Wärmedämmstoffe für Gebäude - An der
formée en place à base de mousse de formaldéhyde (UF) - Anwendungsstelle hergestellte Wärmedämmung aus
Partie 1: Spécification du système de mouse avant la mise Harnstoff-Formaldehydharz-Schaum (UF) - Teil 1:
en place Spezifikation für das Schaumsystem vor dem Einbau
This draft European Standard is submitted to CEN members for enquiry. It has been drawn up by the Technical Committee CEN/TC 88.
If this draft becomes a European Standard, CEN members are bound to comply with the CEN/CENELEC Internal Regulations which
stipulate the conditions for giving this European Standard the status of a national standard without any alteration.
This draft European Standard was established by CEN in three official versions (English, French, German). A version in any other language
made by translation under the responsibility of a CEN member into its own language and notified to the Management Centre has the same
status as the official versions.
CEN members are the national standards bodies of Austria, Belgium, Cyprus, Czech Republic, Denmark, Estonia, Finland, France,
Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Slovakia,
Slovenia, Spain, Sweden, Switzerland and United Kingdom.
Warning : This document is not a European Standard. It is distributed for review and comments. It is subject to change without notice and
shall not be referred to as a European Standard.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION
EUROPÄISCHES KOMITEE FÜR NORMUNG
Management Centre: rue de Stassart, 36 B-1050 Brussels
© 2004 CEN All rights of exploitation in any form and by any means reserved Ref. No. prEN 15100-1:2004: E
worldwide for CEN national Members.
Contents Page
Foreword. 3
1 Scope. 4
2 Normative references . 4
3 Definitions, symbols and abbreviations. 5
4 Requirements . 7
5 Test methods, Conditioning and Testing . 10
6 Designation code . 11
7 Evaluation of conformity. 12
8 Marking, labelling and technical information. 12
Annex A (normative) Determination of declared thermal conductivity and thermal
resistance . 14
A.1 Introduction . 14
A.2 Input data . 14
A.3 Declared values. 14
Annex B (normativ) Factory production control. 16
Annex C (normative) Methods for the determination of the aged value of thermal
conductivity and thermal resistance. 18
C.1 General. 18
C.2 Sampling and test specimen preparation. 18
C.3 Determination of the initial value of thermal conductivity. 18
C.4 Determination of the aged value of thermal conductivity. 18
C.5 Declaration of the aged thermal values. 19
Annex D (normative) Sample preparation method for the specimens for the thermal
conductivity test. 20
D.1 Procedure . 20
Annex E (normative) Sample preparation method for the test specimens other than
thermal conductivity. 21
E.1 Principle . 21
E.2 Apparatus . 21
E.3 Procedure . 21
Annex F (normative) Determination of setting time . 22
F.1 Principle . 22
F.2 Apparatus . 22
F.3 Procedure . 22
F.4 Expression of results. 23
Annex G (informative) Example for the determination of the declared values of thermal
conductivity and thermal resistance for a product . 24
G.1 Case where both thermal conductivity and thermal resistance are declared . 24
Annex ZA (informative) Clauses of this European Standard addressing the provisions of
the EU Construction Products Directive. 26
Foreword
This document (prEN 15100-1:2004) has been prepared by Technical Committee CEN/TC 88
“Thermal insulating materials and products”, the secretariat of which is held by DIN.
This document is currently submitted to the CEN Enquiry.
This document has been prepared under a mandate given to CEN by the European Commission and
the European Free Trade Association, and supports the essential requirements of EU Directive(s).
For relationship with EU Directive(s), see informative Annex ZA, which is an integral part of this
document.
This European Standard consists of two parts. The first part, which is the harmonised part satisfying the
mandate and the CPD and is the basis for the CE marking, covers the products, which are placed on the
market. The second part, which is the non-harmonised part, covers the specification for the installed
products.
This European Standard is one of a series for mineral wool, expanded clay, expanded perlite, exfoliated
vermiculite, polyurethane/polyisocyanurate, cellulose and urea formaldehyde in-situ formed insulation
products used in buildings, but this standard may be used in other areas where appropriate.
1 Scope
This document specifies requirements for in-situ formed urea formaldehyde foam (UF) products when
installed in external walls, internal walls, partitions, floors and roofs. Products covered by this standard
may also be used for acoustic applications.
This document is a specification for the rigid foam dispensing system before installation.
This document describes the product characteristics and includes procedures for testing, marking and
labelling and the rules for evaluation of conformity.
This document does not specify the required level of all properties that should be achieved by a
product to demonstrate fitness for purpose in a particular application. The required levels are to be
found in regulations or non-conflicting standards.
UF products with a declared thermal conductivity at 10 °C (mean temperature) greater than
0,050 W/(mK) are not covered by this document.
This document does not cover factory made products utilising urea formaldehyde foam intended to be
used for the insulation of buildings or for the insulation of building equipment and industrial installations.
This document does not specify all the requirements for the raw materials or the performance
requirements for loadbearing applications.
2 Normative references
The following referenced documents are indispensable for the application of this document. For dated
references, only the edition cited applies. For undated references, the latest edition of the referenced
document (including any amendments) applies.
EN 1602, Thermal insulating products for building applications — Determination of the apparent density
EN 1604, Thermal insulating products for building applications — Determination of dimensional
stability under specified temperature and humidity conditions
EN 1609:1997, Thermal insulating products for building applications — Determination of short term
water absorption by partial immersion
EN 12086:2001, Thermal insulating products for building application — Determination of water vapour
transmission properties
EN 12667:2001, Thermal performance of building materials and products— Determination of thermal
resistance by means of guarded hot plate and heat flow meter method — Products of high and
medium thermal resistance
EN 12939, Thermal performance of building materials and products — Determination of thermal
resistance by means of guarded hot plate and heat flow meter method — Thick products of high and
medium thermal resistance
EN 13172, Thermal insulation products — Evaluation of conformity
EN 13501-1, Fire classification of construction products and building elements — Part 1: Classification
using test data from fire reaction to fire tests
EN 13820, Thermal insulating materials for building applications – Determination of organic content
EN 13823, Reaction to fire tests for building products – Building products excluding floorings exposed to
the thermal attack by a single burning item
prEN ISO 9229, Thermal insulation — Definitions of terms
EN ISO 354:1993/A1:1997, Acoustics — Measurement of sound absorption in a reverberation room
EN ISO 717-2, Acoustics - Rating of sound insulation in buildings and of building elements – Part 2:
Impact sound insulation
EN ISO 1182, Reaction to fire tests for building products – Non-combustibility tests
EN ISO 1716, Reaction to fire tests for building products – Determination of the heat of combustion
EN ISO 11654, Acoustics — Sound absorbers for use in buildings — Rating of sound absorption
EN ISO 11925-2, Reaction to fire tests for building products – Part 2: Ignitability when subjected to
direct impingement of flame
prEN 15100-2, Thermal insulation products for buildings — In-situ formed urea formaldehyde foam
(UF) products — Part 2 Specification for the installed product
ISO 12491, Statistical methods for quality control of building materials and components
3 Definitions, symbols and abbreviations
3.1 Definitions
For the purposes of this document the definitions given in prEN ISO 9229 and the following definitions
apply.
3.1.1
urea formaldehyde foam (UF)
cellular plastics insulation material with a substantially open cell structure based on an amino resin
made by the polycondensation of urea with formaldehyde
3.1.2
urea formaldehyde foam system
the kit of constituent components which when dispensed generates the urea formaldehyde foam (UF)
3.1.3
urea formaldehyde foam (UF) system types
these shall be either Type, 1, Type 2 or Type 3 as detailed in 3.1.4, 3.1
...
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.