SIST EN 50672:2018
(Main)Ecodesign requirements for computers and computer servers
Ecodesign requirements for computers and computer servers
This European Standard provides methods to determine, by means of tests, measurements and/or calculations:
- The energy consumption of desktop computers, integrated desktop computers and notebook computers in OFF mode, with Wake-on-LAN (when available) enabled and disabled;
- The energy consumption of desktop computers, integrated desktop computers and notebook computers in other modes of operation, including low power state(s);
- The lowest power state of desktop computers, integrated desktop computers and notebook computers;
- The Discrete Graphics Card (dGfx) category, when applicable;
- The internal power supply efficiency of desktop computers, integrated desktop computers, computer thin clients, workstations, small-scale servers and computer servers;
- The availability and the behaviour of a power management function.
NOTE The Discrete Graphics Card may not be a physically separate printed circuit board but any hardware providing graphics acceleration function.
This European Standard also suggests methods to determine, when such information is not otherwise available from a trustable source:
- The efficiency of the external power supply supplied with the computer, if applicable;
- The noise level of desktop computers, integrated desktop computers, computer thin clients, workstations, small-scale servers and computer servers;
- The minimum number of loading cycles that the batteries can withstand;
- The total mercury content in the integrated display, when applicable.
This European Standard additionally provides guidance on information to be provided by manufacturers under some Ecodesign programmes or regulations, including, when applicable:
- The results of the above mentioned energy efficiency measurements;
- Energy efficiency parameters calculated from the above measurements (e.g. the total energy consumption, based on a pre-defined duty cycle);
- The external power supply efficiency;
- The noise levels (the declared A-weighted sound power level) of the computer;
- The minimum number of loading cycles that the batteries can withstand;
- Whether internal batteries can be "accessed and replaced by a nonprofessional user", and whether the related text is present and legible on the external packaging;
- User information on power management functionality;
- The total mercury content in the integrated display.
This European Standard applies to desktop computers, integrated desktop computers, notebook computers (including tablet computers, slate computers and mobile thin clients), desktop thin clients, workstations, mobile workstations, small-scale servers and computer servers, that can be powered directly from the mains alternating current (a.c.), including via an external or internal power supply.
This European Standard does not cover blade systems and components, server appliances, multi-node servers, computer servers with more than four processor sockets, game consoles and docking stations.
This European Standard may be applied to any type of computer and computer server not specifically excluded, regardless of its power demand.
Anforderungen an die umweltgerechte Gestaltung von Computern und Computerservern
Exigences d’écoconception applicables aux ordinateurs et aux serveurs informatiques
La présente Norme européenne donne une méthode de détermination, par des essais, des mesures et/ou des calculs:
- de la consommation d'énergie des ordinateurs de bureau, des ordinateurs de bureau intégrés et des ordinateurs portables en mode arrêt (OFF), avec la fonction Wake-on-LAN (le cas échéant) activée ou désactivée;
- de la consommation d'énergie des ordinateurs de bureau, des ordinateurs de bureau intégrés et des ordinateurs portables dans les autres modes de fonctionnement, y compris dans un état à basse puissance;
- du mode d'alimentation le plus bas des ordinateurs de bureau, des ordinateurs de bureau intégrés et des ordinateurs portables;
- de la catégorie de carte graphique séparée (dGfx), le cas échéant;
- du rendement de l'alimentation interne des ordinateurs de bureau, des ordinateurs de bureau intégrés, des clients légers informatiques, des stations de travail, des petits serveurs et des serveurs informatiques;
- de la disponibilité et du comportement d'une fonction de gestion de la consommation d'électricité.
NOTE La "carte graphique séparée" peut ne pas être une carte à circuit imprimé physiquement séparée, mais un matériel remplissant une fonction d'accélération graphique.
Si ces informations ne sont pas par ailleurs disponibles auprès d'une source digne de confiance, la présente Norme européenne suggère également des méthodes de détermination:
- du rendement de l'alimentation externe fournie avec l'ordinateur, le cas échéant;
- du niveau de bruit des ordinateurs de bureau, des ordinateurs de bureau intégrés, des clients légers informatiques, des stations de travail, des petits serveurs et des serveurs informatiques;
- du nombre minimal de cycles de chargement que les batteries peuvent supporter;
- de la teneur totale en mercure de l'écran intégré, le cas échéant.
La présente Norme européenne donne en outre les recommandations relatives aux informations à fournir par les fabricants dans le cadre de certains programmes ou règlements d'écoconception, y compris, le cas échéant:
- Les résultats des mesures de l’efficacité énergétique mentionnées ci-dessus;
- Les paramètres de l’efficacité énergétique calculés à partir des mesures ci-dessus (la consommation totale d'énergie, par exemple, reposant sur un cycle de service préalablement défini);
- Le rendement de l'alimentation externe;
- Les niveaux de bruit (niveau de puissance acoustique pondéré A déclaré) de l’ordinateur;
- du nombre minimal de cycles de chargement que les batteries peuvent supporter;
- Si "un utilisateur non professionnel peut accéder aux batteries internes et les remplacer", et si le texte correspondant est apposé de manière lisible sur l'emballage externe;
- Les informations destinées à l'utilisateur relatives à la fonction de gestion de la consommation d'électricité;
- La teneur totale en mercure de l'écran intégré.
La présente Norme européenne s'applique aux ordinateurs de bureau, aux ordinateurs de bureau intégrés, aux ordinateurs portables (y compris les ordinateurs tablettes, les ordinateurs ardoises et les clients légers mobiles), aux clients légers de bureau, aux stations de travail, aux stations de travail mobiles, aux petits serveurs et aux serveurs informatiques, qui peuvent être alimentés directement par le courant alternatif (AC) du secteur, y compris par l'intermédiaire d'une alimentation externe ou interne.
La présente Norme européenne ne couvre pas les systèmes et composants de type lame, les serveurs monofonctionnels, les serveurs multinœuds, les serveurs informatiques à plus de quatre connecteurs socles pour processeurs, les consoles de jeu et les stations d'accueil.
La présente Norme européenne peut être appliquée à tous les types d'ordinateurs et de serveurs informatiques non spécifiquement exclus, quelle que soit sa demande en énergie.
Zahteve za okoljsko primerno zasnovo računalnikov in računalniških strežnikov
Ta evropski standard predpisuje metode, s katerimi se s pomočjo preskusov, merjenja in/ali izračunov določa:
– poraba energije namiznih računalnikov, integriranih namiznih računalnikov in prenosnih računalnikov v načinu OFF (izklop) z omogočeno in onemogočeno funkcijo Wake-on-LAN (prebujanje prek omrežja), če je ta na voljo;
– poraba energije namiznih računalnikov, integriranih namiznih računalnikov in prenosnih računalnikov v drugih načinih delovanja, vključno z načinom nizke porabe energije;
– stanje najnižje porabe namiznih računalnikov, integriranih namiznih računalnikov in prenosnih računalnikov;
– kategorija ločene grafične kartice (dGfx), kadar je to primerno;
– učinkovitost notranjega napajanja namiznih računalnikov, integriranih namiznih računalnikov, računalniških tankih odjemalcev, delovnih postaj, majhnih strežnikov in računalniških strežnikov;
– razpoložljivost in delovanje funkcije za upravljanje porabe energije.
OPOMBA: Ločena grafična kartica ni nujno fizično ločeno tiskano vezje, temveč katera koli strojna oprema, ki zagotavlja funkcijo pospeševanja grafike.
Ta evropski standard predlaga tudi metode, s katerimi se, če takšne informacije sicer niso na voljo iz zanesljivega vira, določa:
– učinkovitost zunanjega napajanja, ki jo ima računalnik, če je to ustrezno;
– raven hrupa namiznih računalnikov, integriranih namiznih računalnikov, računalniških tankih odjemalcev, delovnih postaj, majhnih strežnikov in računalniških strežnikov;
– najmanjše število ciklov polnjenja, ki jih lahko prenesejo baterije;
– skupna vsebnost živega srebra v integriranem zaslonu, kadar je to ustrezno.
Ta evropski standard dodatno zagotavlja smernice za informacije, ki jih morajo proizvajalci navesti v okviru nekaterih programov ali predpisov za okoljsko primerno zasnovo, kar vključuje naslednje informacije (kadar je to primerno):
– rezultati zgoraj navedenih meritev energetske učinkovitosti;
– parametri energetske učinkovitosti, izračunani iz zgornjih meritev (npr. skupna poraba energije na podlagi vnaprej določenega delovnega cikla);
– učinkovitost zunanjega napajanja;
– raven hrupa računalnika (deklarirana z ravnjo zvočne moči po lestvici A);
– najmanjše število ciklov polnjenja, ki jih lahko prenesejo baterije;
– ali lahko do notranje baterije »dostopa in jo zamenja uporabnik brez strokovnega znanja« ter ali je to besedilo prisotno in berljivo na zunanji embalaži;
– uporabniške informacije o funkciji upravljanja porabe energije;
– skupna vsebnost živega srebra v integriranem zaslonu.
Ta evropski standard se uporablja za namizne računalnike, integrirane namizne računalnike, prenosne računalnike (vključno s tabličnimi računalniki, tablicami brez tipkovnice in tankimi odjemalci za mobilne naprave), namizne tanke odjemalce, delovne postaje, mobilne delovne postaje, majhne strežnike in računalniške strežnike, ki jih je mogoče napajati neposredno na izmenični tok, vključno prek zunanjega ali notranjega napajalnika.
Ta evropski standard ne zajema sistemov rezin in komponent, strežniških naprav, strežnikov z več vozlišči, računalniških strežnikov z več kot štirimi priključki procesorja, igralnih konzol in priključnih postaj.
Ta evropski standard se lahko uporablja za vse vrste računalnikov in računalniških strežnikov, ki niso izrecno izključeni, ne glede na njihove zahteve po napajanju.
General Information
Relations
Standards Content (Sample)
SLOVENSKI STANDARD
SIST EN 50672:2018
01-april-2018
=DKWHYH]DRNROMVNRSULPHUQR]DVQRYRUDþXQDOQLNRYLQUDþXQDOQLãNLKVWUHåQLNRY
Ecodesign requirements for computers and computer servers
Anforderungen an die umweltgerechte Gestaltung von Computern und Computerservern
Exigences d’écoconception applicables aux ordinateurs et aux serveurs informatiques
Ta slovenski standard je istoveten z: EN 50672:2017
ICS:
35.160 Mikroprocesorski sistemi Microprocessor systems
SIST EN 50672:2018 en,fr,de
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
---------------------- Page: 1 ----------------------
SIST EN 50672:2018
---------------------- Page: 2 ----------------------
SIST EN 50672:2018
EUROPEAN STANDARD EN 50672
NORME EUROPÉENNE
EUROPÄISCHE NORM
November 2017
ICS 35.160
English Version
Ecodesign requirements for computers and computer servers
Exigences d'écoconception applicables aux ordinateurs et Anforderungen an die umweltgerechte Gestaltung von
aux serveurs informatiques Computern und Computerservern
This European Standard was approved by CENELEC on 2017-08-28. CENELEC members are bound to comply with the CEN/CENELEC
Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC
Management Centre or to any CENELEC member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation
under the responsibility of a CENELEC member into its own language and notified to the CEN-CENELEC Management Centre has the
same status as the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic,
Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia,
Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden,
Switzerland, Turkey and the United Kingdom.
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels
© 2017 CENELEC All rights of exploitation in any form and by any means reserved worldwide for CENELEC Members.
Ref. No. EN 50672:2017 E
---------------------- Page: 3 ----------------------
SIST EN 50672:2018
EN 50672:2017 (E)
Contents Page
European foreword . 4
Introduction . 5
1 Scope . 6
2 Normative references . 7
3 Terms, definitions and abbreviations . 7
3.1 Terms and definitions . 7
3.2 Abbreviations . 8
4 Energy efficiency parameters . 8
4.1 Energy consumption in off mode . 8
4.1.1 Off mode without Wake-On-LAN . 8
4.1.2 Off mode with Wake-On-LAN . 9
4.2 Energy consumption in sleep mode . 9
4.2.1 Sleep mode without Wake-On-LAN. 9
4.2.2 Sleep mode with Wake-On-LAN . 9
4.3 Default settings of the EUT, as supplied to the end-user, shall be used for this test.
However, if the EUT supports WOL, that function shall be enabled.Energy consumption in
idle mode . 9
4.4 Energy consumption in the lowest power mode . 10
4.5 Annual total energy consumption. 10
4.6 Internal Power Supply (IPS) efficiency and power factor . 10
4.7 External power supply efficiency . 11
4.8 Discrete Graphics Card (dGfx) category . 11
4.9 Power management functions . 12
4.9.1 Activation and deactivation of wireless network connections . 12
4.9.2 Display sleep mode . 12
4.9.3 Computer sleep mode (without Wake-On-LAN) . 13
4.9.4 Computer sleep mode (with Wake-On-LAN) . 13
5 Non-energy efficiency related parameters . 13
5.1 Noise levels . 13
5.2 Minimum number of loading cycles that batteries can withstand . 14
5.3 Internal batteries replacement . 14
5.4 Total content of mercury in integrated display . 14
6 Test setup, test conditions, and measurement instrument specifications . 15
6.1 General conditions for measurement . 15
6.1.1 General . 15
6.1.2 Test room . 15
6.1.3 Power source . 15
6.1.4 Power measuring instruments . 15
6.1.5 Measurement uncertainty . 15
6.2 Requirements applicable to low power measurements . 15
6.3 Internal power supply efficiency measurements . 15
6.3.1 General . 15
6.3.2 Test loads . 16
6.3.3 Test leads and wiring . 16
6.3.4 Warm up time . 16
6.3.5 Power measurements . 16
6.3.6 Power Factor (PF) measurement . 16
2
---------------------- Page: 4 ----------------------
SIST EN 50672:2018
EN 50672:2017 (E)
Verification procedure for the power management functions . 16
6.4
6.4.1 Enabling and disabling wireless connections . 16
6.4.2 Display sleep mode . 17
6.4.3 Sleep mode without WOL . 17
6.4.4 Sleep mode with WOL . 17
Annex A (normative) Test conditions for data connections . 18
A.1 Connection types and test conditions . 18
Annex B (informative) Theoretical duty cycles applicable to certain categories of computer
under Regulation (EU) N° 617/2013 . 19
B.1 Desktop computer and integrated desktop computer . 19
B.2 Notebook computers . 19
Annex C (informative) Considerations for Internal and external fan control . 20
C.1 Introduction . 20
C.2 Multiple-output Power Supply Fan Control through Temperature Sense (Internal Control) . 20
C.3 Multiple-output Power Supply Fan Control through External Voltage Signal (External
Control) . 20
Annex D (informative) Templates for information provision . 21
D.1 Templates by computer type . 21
Annex ZZ (informative) Relationship between this European Standard and the ecodesign
requirements of Commission Regulation (EU) No 617/2013 aimed to be covered . 26
Bibliography . 28
3
---------------------- Page: 5 ----------------------
SIST EN 50672:2018
EN 50672:2017 (E)
European foreword
This document (EN 50672:2017) has been prepared by Technical Committee CLC/TC 100X, “Audio, video
and multimedia systems and equipment and related sub-systems”, Working Group 02, “Energy efficiency”.
The following dates are fixed:
latest date by which this document has to be (dop) 2018-08-28
implemented at national level by publication of an
identical national standard or by endorsement
latest date by which the national standards (dow) 2020-08-28
conflicting with this document have to be withdrawn
Attention is drawn to the possibility that some of the elements of this document may be the subject of patent
rights. CENELEC shall not be held responsible for identifying any or all such patent rights.
This document has been prepared under a mandate given to CENELEC by the European Commission and
the European Free Trade Association, and supports essential requirements of EU Directive(s).
For the relationship with EU Directive(s) see informative Annex ZZ, which is an integral part of this document.
4
---------------------- Page: 6 ----------------------
SIST EN 50672:2018
EN 50672:2017 (E)
Introduction
A preparatory study carried out by the European Commission estimated the cost-efficient improvement
potential in the electricity consumption of computers between 2011 and 2020 at about 93 TWh, which
corresponds to 43 Mt of CO2 emissions, and in 2020 at between 12,5 TWh and 16,3 TWh, which corresponds
to 5,0-6,5 Mt of CO2 emissions. Consequently, computers constitute a product group for which Ecodesign
requirements have been established.
Since much of the energy-savings potential of desktop thin clients, workstations, small-scale servers and
computer servers is linked to the efficiency of their internal power supplies and since the technical
specifications of internal power supplies for these products are similar to those for desktop computers and
integrated desktop computers, the provisions on internal power supply efficiency set up for desktop computers
also apply to desktop thin clients, workstations, small-scale servers and computer servers.
While the focus is put on energy consumption, computer products (and energy-related products in general)
are expected to be designed in such a way to also preserve other resources.
The present European Standard provides a way to determine compliance of computers and computer servers
in scope of Commission Regulation (EU) N° 617/2013 with the applicable requirements through reliable,
accurate and reproducible measurement methods, which take into account the recognized state of the art,
including, where available, existing harmonized standards established in conformity with the applicable
European standardization legislation. It also provides guidance for declarations that are required under the
same Regulation.
5
---------------------- Page: 7 ----------------------
SIST EN 50672:2018
EN 50672:2017 (E)
1 Scope
This European Standard provides methods to determine, by means of tests, measurements and/or
calculations:
— The energy consumption of desktop computers, integrated desktop computers and notebook computers
in OFF mode, with Wake-on-LAN (when available) enabled and disabled;
— The energy consumption of desktop computers, integrated desktop computers and notebook computers
in other modes of operation, including low power state(s);
— The lowest power state of desktop computers, integrated desktop computers and notebook computers;
— The Discrete Graphics Card (dGfx) category, when applicable;
— The internal power supply efficiency of desktop computers, integrated desktop computers, computer thin
clients, workstations, small-scale servers and computer servers;
— The availability and the behaviour of a power management function.
NOTE The “Discrete Graphics Card” may not be a physically separate printed circuit board but any hardware
providing graphics acceleration function.
This European Standard also suggests methods to determine, when such information is not otherwise
available from a trustable source:
— The efficiency of the external power supply supplied with the computer, if applicable;
— The noise level of desktop computers, integrated desktop computers, computer thin clients, workstations,
small-scale servers and computer servers;
— The minimum number of loading cycles that the batteries can withstand;
— The total mercury content in the integrated display, when applicable.
This European Standard additionally provides guidance on information to be provided by manufacturers under
some Ecodesign programmes or regulations, including, when applicable:
— The results of the above mentioned energy efficiency measurements;
— Energy efficiency parameters calculated from the above measurements (e.g. the total energy
consumption, based on a pre-defined duty cycle);
— The external power supply efficiency;
— The noise levels (the declared A-weighted sound power level) of the computer;
— The minimum number of loading cycles that the batteries can withstand;
— Whether internal batteries can be “accessed and replaced by a nonprofessional user”, and whether the
related text is present and legible on the external packaging;
— User information on power management functionality;
— The total mercury content in the integrated display.
This European Standard applies to desktop computers, integrated desktop computers, notebook computers
(including tablet computers, slate computers and mobile thin clients), desktop thin clients, workstations, mobile
6
---------------------- Page: 8 ----------------------
SIST EN 50672:2018
EN 50672:2017 (E)
workstations, small-scale servers and computer servers, that can be powered directly from the mains
alternating current (a.c.), including via an external or internal power supply.
This European Standard does not cover blade systems and components, server appliances, multi-node
servers, computer servers with more than four processor sockets, game consoles and docking stations.
This European Standard may be applied to any type of computer and computer server not specifically
excluded, regardless of its power demand.
2 Normative references
The following documents, in whole or in part, are normatively referenced in this document and are
indispensable for its application. For dated references, only the edition cited applies. For undated references,
the latest edition of the referenced document (including any amendments) applies.
EN 50563:2011, External a.c. - d.c. and a.c. - a.c. power supplies – Determination of no-load power and
average efficiency of active modes
EN 50564:2011, Electrical and electronic household and office equipment - Measurement of low power
consumption
EN 61960:2011, Secondary cells and batteries containing alkaline or other non-acid electrolytes - Secondary
lithium cells and batteries for portable applications
EN 62321-4, Determination of certain substances in electrotechnical products - Part 4: Mercury in polymers,
metals and electronics by CV-AAS, CV-AFS, ICP-OES and ICP-MS (IEC 62321-4)
EN 62554:2011, Sample preparation for measurement of mercury level in fluorescent lamps (IEC 62554:2011)
EN 62623:2013, Desktop and notebook computers - Measurement of energy consumption (IEC 62623:2012)
ECMA-74, Measurement of Airborne Noise emitted by Information Technology and Telecommunications
Equipment, 13th edition (June 2015)
ECMA-109, Declared Noise Emission Values of Information Technology and Telecommunications Equipment,
6th edition (December 2012)
3 Terms, definitions and abbreviations
3.1 Terms and definitions
For the purposes of this document, the following term and definition applies.
NOTE 1 Further terms and definitions from standards and regulations related to the topic of this standard can be found
in the compendium of terms used in Ecodesign Directives, Regulations and Standards, maintained by the CEN-CENELEC
Ecodesign Coordination Group (EcoCG).
NOTE 2 When this European Standard is used to give presumption of conformity to a European Directive or
Regulation, definitions given in the Directive or Regulation prevail.
3.1.1
rated output power
maximum continuous output power of the power supply, as specified by the manufacturer
Note 1 to entry: In EC Regulation 278/2009 the corresponding term is “nameplate output power”.
[SOURCE: EN 50563:2011, definition 3.1.5, modified by removal of “external”]
7
---------------------- Page: 9 ----------------------
SIST EN 50672:2018
EN 50672:2017 (E)
3.2 Abbreviations
a.c. alternating current
CPU Central Processing Unit
d.c. direct current
DDR Double Data Rate (applies to memory chips)
dGfx Discrete Graphics Card
EPS External Power Supply
ESD Electrostatic Discharge
ETEC Total Energy Consumption (over a one-year period)
EUT Equipment Under Test
FB_BW Frame Buffer Bandwidth
GB/s GigaByte per second
GDDR Graphics Double Data Rate (applies to memory chips)
LAN Local Area Network
LCD Liquid Crystal Display
LED Light Emitting Diode
LISN Line Impedance Stabilization Network
mg milligrams
PF Power Factor
PFC Power Factor Correction
Pidle Power in idle state
Poff Power in off mode
Psleep Power in sleep mode
RAM Random Access Memory
RoHS Restriction of the Use of Certain Hazardous Substances
RMS Root Mean Square
WOL Wake-On-LAN
4 Energy efficiency parameters
4.1 Energy consumption in off mode
4.1.1 Off mode without Wake-On-LAN
Energy consumption in off-mode shall be determined in accordance with EN 62623:2013, 5.3.2.
Measurement shall be performed on desktop computers, integrated desktop computers, and notebook
computers, after they automatically switched to off mode, as a result of a given period of inactivity. In addition
to the energy consumption, the length of the inactive period after which the computer automatically switches
to off mode shall be measured and recorded.
Test setup, test conditions, and measurement instrument specifications shall comply with 6.1.
8
---------------------- Page: 10 ----------------------
SIST EN 50672:2018
EN 50672:2017 (E)
If off mode without Wake-on-LAN is not the low power mode into which the computer automatically switches
after a certain period of inactivity, the computer shall be manually forced into off mode without Wake-on-LAN
for the purpose of the measurement.
4.1.2 Off mode with Wake-On-LAN
For desktop computers, integrated desktop computers and notebook computers with Wake-On-LAN in off
mode functionality enabled as factory default, the measurement shall be repeated after Wake-On-LAN from
off mode has been re-enabled through the operating system or by other means, and the EUT placed back in
off mode.
Measurement shall be performed on desktop computers, integrated desktop computers, and notebook
computers, after they automatically switched to off mode with Wake-On-LAN, as a result of a given period of
inactivity. In addition to the energy consumption, the length of the inactive period after which the computer
automatically switches to off mode with Wake-On-LAN shall be measured and recorded.
Test setup, test conditions, and measurement instrument specifications shall comply with 6.1.
If off mode with Wake-on-LAN is not the low power mode into which the computer automatically switches after
a certain period of inactivity, the computer shall be manually forced into off mode with Wake-on-LAN for the
purpose of the measurement.
4.2 Energy consumption in sleep mode
4.2.1 Sleep mode without Wake-On-LAN
Energy consumption in sleep mode shall be determined in accordance with EN 62623:2013, 5.3.3.
Measurement shall be performed on desktop computers, integrated desktop computers, and notebook
computers, after they automatically switched to sleep mode, as a result of a given period of inactivity. In
addition to the energy consumption, the length of the inactive period after which the computer automatically
switches to sleep mode shall be measured and recorded.
Test setup, test conditions, and measurement instrument specifications shall comply with 6.1.
Default settings of the EUT, as supplied to the end-user, shall be used for this test. However, if the EUT
supports WOL, that function shall be disabled.
4.2.2 Sleep mode with Wake-On-LAN
For desktop computers, integrated desktop computers and notebook computers with Wake-On-LAN in sleep
mode functionality enabled as factory default, the energy consumption in sleep mode with Wake-On-LAN
enabled shall also be determined in accordance with EN 62623:2013, 5.3.3.
Measurement shall be performed on desktop computers, integrated desktop computers, and notebook
computers, after they automatically switched to sleep mode with Wake-On-LAN, as a result of given period of
inactivity. In addition to the energy consumption, the length of the inactive period after which the computer
automatically switches to sleep mode with Wake-On-LAN shall be measured and recorded.
Test setup, test conditions, and measurement instrument specifications shall comply with 6.1.
4.3 Default settings of the EUT, as supplied to the end-user, shall be used for this test.
However, if the EUT supports WOL, that function shall be enabled.Energy consumption in
idle mode
For desktop computers, energy consumption in idle state shall be determined in accordance with
EN 62623:2013, 5.3.5 (“short idle”).
For integrated desktop computers, energy consumption in idle state shall be determined in accordance with
EN 62623:2013, 5.3.4 (“long idle”).
For notebook computers, energy consumption in idle state shall be determined in accordance with
EN 62623:2013, 5.3.4 (“long idle”).
9
---------------------- Page: 11 ----------------------
SIST EN 50672:2018
EN 50672:2017 (E)
Test setup, test conditions, and measurement instrument specifications shall comply with 6.1.
4.4 Energy consumption in the lowest power mode
For desktop computers, integrated desktop computers and notebook computers where the off mode is the
lowest power state, the energy consumption in the lowest power state is identical to the one determined in
accordance with 4.1.1.
NOTE There is no need to duplicate this measurement if no additional state is provided.
For desktop computers, integrated desktop computers and notebook computers with an additional power
state, where the power demand is lower than in off mode, an additional measurement shall be made in
accordance with EN 62623:2013, 5.3.2, where “off mode” is replaced by that additional state.
4.5 Annual total energy consumption
Annual total energy consumption shall be determined, using a theoretical duty cycle, taking into account the
energy consumption measured in off mode, sleep mode and idle state. Subclauses 4.1 to 4.4 indicate how to
measure the energy consumption in each of those 3 states.
For computers lacking a discrete sleep mode, energy consumption measured in idle state may, under certain
conditions, replace the energy consumption in sleep mode in the applicable formula.
NOTE 1 According to regulation (EU) N° 617/2013, power in idle state (Pidle) may be used in place of sleep mode
(Psleep) for desktop computers and integrated desktop computers that lack a discrete sleep mode, but have idle state
power demand less than or equal to 10 W.
NOTE 2 Examples of theoretical duty cycles applicable to certain categories of computer under Regulation (EU) N°
617/2013 are given in Annex B.
NOTE 3 Applicable limits to the annual total energy consumption may depend on the type of computer as well as the
category of the installed and enabled discrete graphics card(s), if any.
4.6 Internal Power Supply (IPS) efficiency and power factor
The efficiency and the power factor of the internal power supply shall be measured for desktop computers,
integrated desktop computers, thin clients, workstations, small-scale servers and computer servers.
For all types of internal power supplies, the efficiency and the power factor shall be measured at 20 %, 50 %
and 100 % of the rated [nameplate] output power.
For single output internal power supplies, the efficiency shall also be measured at 10 % of the rated
[nameplate] output power.
For single output internal power supplies with a rated output power greater than 500 W, the power factor shall
also be measured at 10 % of the rated [nameplate] output power.
Test setup, test conditions, and measurement instrument specifications shall comply with 6.3.
This test procedure assumes that the internal power supply meets following criteria:
— Detailed input and output ratings are available on the name plate or in manufacturer’s literature,
specifying the maximum loads that can safely be placed on each individual dc output voltage bus and,
where necessary, groupings of those voltage busses.
— The power supply has connectors that allow the d.c. output voltage busses to be connected and
disconnected from the powered product non-destructively.
— The power supply can be easily detached from the housing of the product it powers, without causing
harm to other circuits and components of the product
In the event the above criteria are not met, a test board shall be provided to enable testing.
10
---------------------- Page: 12 ----------------------
SIST EN 50672:2018
EN 50672:2017 (E)
NOTE 1 The EPRI /ECOVA, Generalized Test Protocol for Calculating the Energy Efficiency of Internal Ac-Dc and Dc-
Dc Power Supplies (Revision 6.6, April 2012 or Revisio
...
Questions, Comments and Discussion